acrydig

June 8, 2018 | Author: JessyHuangChen | Category: Electrical Connector, Cable, Manufactured Goods, Water, Electromagnetism


Comments



Description

ACRYDIG 4 -10INTRODUCTION This instruction is an integral part of the delivery device and has to be accompanied during any migration. Operating be retained for the lifetime of the device and under all circumstances for at least 10 years, must therefore keep a familiar place and must be accessible to all who work with it work. Do instrument or do not start until you read this manual. Fig. 1 1. 2. 3. 4. Cover Control panel for temperature Main switch Cable and plug SPECIFICATIONS L'ACRYDIG 4 comes in Following COMES design 220/240 V 50/60 Hz L'ACRYDIG 10 is supplied following execution 220/240 50/60 Hz Power consumptio n Width Height Depth Net weight ACRYDIG 4 1100W ACRYDIG 10 1430 W 13 cm + 2 cm in supply cable 37.5 cm 42 c m 8 kg 28 cm + 2 cm in supply cable 37.5 cm 42 cm 10 kg APPLICATION EQUIPMENT Acrydig 4 and 10 are polymerizátory Acrydig resin. They inserted into them in resin models unset state and a certain amount of water. Device heats the water to a temperature below the boiling point, which is maintained for the required period and the heating is continued until the desired final temperature, which is also maintained for the required period.This cycle processes causing polymerization resins. Unpacking The unit is supplied in cardboard kabici. Before unpacking, remove metal pins on the top of the box and then remove polymerizátor. Manufacturer disclaims responsibility for any damage caused by failure to comply with this requirement. If he accidentally started in the heating cycle the absence of water. .NOTICE Check that: AC cord and plug are not damaged on polymerizátoru no evidence of damage or fall Electricity has interrupting the safety earth connection it Nevnořujte cable into the water. Do not let the cord hang over the edges of furniture. the figure on the display increases Not during runtime. the display stops flashing. the heating cycle is terminated When pressed after a power failure. stable surface to hold its weight. Polymerizátor must be connected to the correct current and voltage according to its technical characteristics and must be grounded. INSTALLATION - Place the device on a flat. When pressed during programming. the figure goes on display Not during runtime. When pressed during the programming. It allows for programming. The appliance must be earthed. FUNC - Presses when the device is in rest (OFF on the lower display). the resistance burned. inserting parameters and their preservation. Keep cable well away from heat sources. They must be installed by a qualified electrician able to check the grounding. CONTROL PANEL Buttons RUN   - Press to start the heating cycle us Pressed for about 6 seconds. Pour the water into the unit before any manipulation. shows the temperature and time that must be loaded into memory or altered During the run-in phase. Press FUNC and start programming. see the parameters of the heating cycle without interruption. Press FUNC: the lower display shows SP2 and upper programmed final temperature. Press FUNC: the lower display shows SP1 and the top shows the programmed transition (first) temperature. This parameter can not be changed. proceed to the tkaže next point. LIGHTS OUT SP TIME - This indicator lights when the current heating resistors This indicator lights when the temperature rises.- When pressed during runtime. On the lower display shows the FSE and the upper 0. BOTTOM This display shows OFF when the device is in peace When programming or changing parameter settings shown in the following abbreviations: FSE current stage SP1 first temperature to be stabilized TS1 period during which to maintain the first temperature SP2 final temperature TS2 time during which to keep the final temperature INSTRUCTIONS FOR CONTROL Programming Note: You can program only when the device is in rest (OFF on the lower display and lights SP TIME and off). To change the temperature to the desired value by pressing the  or . To change the temperature to the desired value by pressing the  or . This light is turned on during a phase of stabilization DISPLAY UPPER During programming. Yapněte yaříyení main switch. showing the rise of water temperature in the stabilization phase shows the relevant times. This time change to the desired value by pressing the  or . Turns off when the programmed temperature is reached. Press FUNC: the lower display shows the TS1 and the top shows the programmed time maintaining the temporary (first) temperature. . Start heating cycle by pressing RUN. STEAM POLYMERIZATION When steam polymerization. Starting the program Note: You can program only when the device is in rest (OFF on the lower display and lights SP TIME and off). pressing the FUNC. follow these steps: polymerizátoru to pour enough water so that the aid of shock absorbers remain under water. and the program stops. The two previous stages are repeated in the ascent to the final t ePlot and its stabilization. the program will start again the point where it was interrupted. On the lower display shows again the word OFF. Stop flashing. the light goes out and the warning light TIME. This time change to the desired value by pressing the  or . it is necessary to bear in mind the fact that the boiling point is different at different altitudes. On the lower display shows OFF and the upper appear instantaneous temperature. Do not use a provisional (temporary) temperature. but the displays are flashing. Then set the final temperature and the appropriate duration corresponding to the time required for the polymerization (usually 6 to 8 hours). Stopping the program Press RUN to about 6 seconds. Once this temperature is reached. so that the device is adjusted to a final temperature (usually between 70 and 80   C) corresponding to the minimum time (1 minute). press RUN. Height (m) Boiling Point  C) 500 98 1000 97 1500 95 2000 93 2500 92 3000 90 If you set the temperature higher than the boiling point. can not be achieved and the cycle thus be unable to continue. . Lamp lights SP and the lower display shows the temperature to be reached. Shock itself to be out of the water. The lower display shows the time remaining to stabilize. as it ukayuje following table. Note: if you want to bring water to a boil.- Press FUNC: the lower display will appear on the upper and TS2 programmed time during which to keep the final temperature. Exit the programming phase. Blackout If the power supply fails. GUARANTEE On the instrument are warranted for 12 months. The warranty does not cover charges for labor or services that are always and in all circumstances be borne by the buyer. The warranty will be void in cases of improper use. Have cast warranty card is immediately void the warranty.Caution: Always make sure that your heating system is underwater. . damage to or use of spare parts that n epocházejí from producer.
Copyright © 2024 DOKUMEN.SITE Inc.