Acceptance Guideline for iPASOLINK 200 Page2

March 24, 2018 | Author: Golap Rahman | Category: Ip Address, Internet Protocols, Communications Protocols, Network Protocols, Digital Technology


Comments



Description

Acceptance GuidelineiPasolink 200 Version 1.0 This guideline has been prepared based on acceptance checklist for ipasolink 200. Each point in the acceptance checklist has been described here maintaining the serial. Procedure of data measurement has been clearly stated in this guideline. General information All data of general information will be taken from ROC. i. Serial Number Serial number of each part will be taken from physical equipment. ii.   Meter Reading Specification Line voltage will be taken from direct power line by multi meter. ODU voltage will be measured from ODU port by multi meter. iii. Transmit RF power measurement This data will be measured by LCT in the following way. v. If alarm is cleared then loop is OK. Menu  Equipment setup  Equipment configuration Equipment current status  TX Power control Check this value with planned data from ROC. Receive Level This data will be measured by LCT in the following way. ix. Physical Loopback Test For STM port back to back loop will be needed by a STM cable. vi. . vii.Acceptance guideline Menu  Metering  Current metering  TX power Check this value with planned data from ROC.3 dB) from ROC. Radio Frequency Measurement This data will be measured by LCT in the following way. For tributary port U link will be needed to create a loop in DDF. Menu  Equipment setup  Equipment configuration Equipment current status  TX RF frequency/RX RF frequency Check this value with planned data from ROC. Menu  Equipment setup  Equipment configuration Equipment current status  Reference modulation Check this value with planned data from ROC. If alarm for that tributary port is cleared then loop is OK. After checking clear all loops. viii. Modulation This data will be measured by LCT in the following way. BER Test If there is STM-1 port then this test will be done by BER tester connecting STM-1 cable between STM port of ipasolink and BER tester and duration 24H. ipasolink 200 iv. Power Control Setting This data will be measured by LCT in the following way. Menu  Metering  Current metering  RX power Check this value with planned data (+/. x. No. Checklist No. No. xi. . Menu  Inventory  Equipment inventory information  Firmware information  main board  current version The picture of the window is shown below. Interference Test Check interference by making TX mute at far end and measuring RX level at near end in the following way. If in any case it doesn‟t work then manually make it OFF. 1 to No. 25 to No.Acceptance guideline ipasolink 200 If there is no STM-1 port then use one 2 MB port for 12 H BER test from evening to morning. 39 to No. 37  Data will be collected from measurement (mentioned above) and physical equipment. No. In case of reset no traffic cable should be affected. 41  Firm ware version will be collected from LCT in the following way. 38  In ipasolink 200 there is no power switch. Due to this power cable should be separate from traffic cable. 24  Data will be collected from physical equipment and environment. That‟s why to reset the IDU power cable will have to plug out which will be needed during operation. No. 40  Data will be collected from physical equipment. Menu  Maintenance Control  Modem maintenance control  TX mute control In normal case after 30 minute TX mute should be automatically removed. Acceptance guideline ipasolink 200 No. Go to Menu  Equipment set up  Radio Configuration New setting 2. Check ETH bandwidth [Mbps] 3. Set 2 at E1 mapping [ch] . 42  This should be tested by setting 2 E1 in E1 mapping and measuring ETH bandwidth in the following way. 1. Now the value should be = (previous bandwidth -4). . Check ETH bandwidth [Mbps].Acceptance guideline ipasolink 200 4. Click OK. 5. Click Next 6. Again click OK . 1.Acceptance guideline ipasolink 200 No. Go to Menu  Provisioning  E1/STM-1/Cross connect settingE1 port setting  click modify 2. 43 This should be tested making cross connection by LCT in the following way. Select „Used‟ for CH01 3. Click OK 4. 7. 11. Go to Menu  Provisioning  E1/STM-1/Cross connect setting Cross connect setting click ‘Add’ Set 1 at service no. 13. Set ‘Test’ at service name. 14.Acceptance guideline ipasolink 200 5. 8. . 12.A and select modem1 in Edge. Cross connect type : E1 Select ‘main board’ in Edge. Go to Menu  Provisioning  E1/STM-1/Cross connect setting Cross connect setting Check the cross connection. 6. 9.B Select row#1 under main board and row#1 under modem1 Click OK Again click OK. 10. 3. 1.Acceptance guideline ipasolink 200 After checking the cross connection delete the cross connection in the following way. Go to Menu  Provisioning  E1/STM-1/Cross connect setting Cross connect setting  click Delete 2. Click OK. . Set 1 at service No. No. 45  Check factory test data sheet.Acceptance guideline ipasolink 200 Do the following actions. No. No. Select „Not Used‟ for CH01 3. 44  This will be taken by LCT in the following way. 1. Go to Menu  Provisioning  E1/STM-1/Cross connect settingE1 port setting  click modify 2. Menu  Equipment set up  AMR configuration  set up  New setting Select AMR mode and check all modulations as USED. 46  This will be taken by LCT in the following way. Go to Menu  Equipment set up  Radio Configuration New setting Set 0 at E1 mapping [ch] Click Next Click OK. 1. . Click OK Also do the following actions. 2. Menu  Inventory  S/W License information Check all feature availability. 4. 3. Check some values in E1 mapping.Acceptance guideline ipasolink 200 Then click next. . Check radio mapping. Click next. ] MEG ID = NEC-GP [any word.Acceptance guideline ipasolink 200 No. 47  This will be taken by Ethernet analyzer or following procedure: ETHERNET Function Setting: Step-1: Go to ProvisioningETH Function SettingETH Port Setting Enable port-1/port-2/port3/port-4 Step-2: Go to Provisioning ETH Function SettingVLAN SettingVLAN List Add VLAN ID  Create VLAN 10 Step-3: Go to Provisioning ETH Function SettingVLAN SettingVLAN Setting  Select VLAN ID 10 for MODEM-1(we check ETH function for One VLAN ID) Step-4: Go to Provisioning ETH Function SettingETH OAM SettingOAM MEG Add MEG Example for setting: put MEG INDEX = 1 [if there is no any previous index otherwise put 2 or 3 etc. keep in mind that far-end must be same word] MEG LEVEL =7 [any value 1~7. keep in mind that far-end must be same value] ETH CC =3.3ms .  Enable the VLAN service as showing below Enable MEG Configuration as showing below-   CCM Transmit and CCM Receive= Enable Add MEP Configuration. keep in mind that far-end Peer MEP ID must be same] CCM Priority =7 [any value 1~7. Note: do the same configurations for far-end site.Acceptance guideline ipasolink 200 Step-5: Go to Provisioning ETH Function SettingETH OAM SettingOAM MEP Add MEP Example for setting: put MEP INDEX = 1 [if there is no any previous index otherwise put 2 or 3 etc. keep in mind that far-end must be same value] ITEM =MODEM1 [Item Must be modem1 as we check only modem-modem Ethernet performance] Port = Port01 After assigning it will show the Source MAC address. put “Peer MEP ID = far-end MEP ID” and check on “Peer List check Status Enabled. . Write down the source MAC address.] MEP ID = 2 [any number. [MAC Address will be different for different IDU/Modem]  OK  It will show the following successful LB result- .Acceptance guideline ipasolink 200 ETH-OAM test Step-6: Go to Maintenance TestETH OAM LB/LT ControlModify Test Type  Choose LB  MEP Index =1 [must be the same value as given in Step-5]  Destination MAC address = Source MAC address of far-end MODEM1 as got during Step-5. Do the same test for far-end. Step-7: Go to Maintenance TestETH OAM LB/LT ControlModify Test Type  Choose LT  MEP Index =1 [must be the same value as given in Step-5]  Destination MAC address = Source MAC address of far-end MODEM1 as got during Step-5.  OK It will show the following successful LT result- .Acceptance guideline ipasolink 200 Note: Result must show “Receive”. Make sure that LB result is showing the same VLAN ID/MEP ID/MEG ID and MEG LEVEL which are configured in earlier steps. 11: bytes=32 bytes=32 bytes=32 bytes=32 bytes=32 bytes=32 bytes=32 bytes=32 time<1ms time<1ms time<1ms time<1ms time<1ms time<1ms time<1ms time<1ms TTL=64 TTL=64 TTL=64 TTL=64 TTL=64 TTL=64 TTL=64 TTL=64 . it is recommended to remove MEG.255.210. otherwise “Ping 192.it is required to assign IP address in two PC as given example Step-1: Assign IP address on near-end PC (not Mandatory could be assign any valid IP) IP address: 192.11 -t After few minutes  Press CTRL+C for stop checking Then see the following example result Pinging 192.210.10 Subnet mask: 255.210.255.210.168. VLAN port type and VLAN ID[CCM Transmit and CCM Receive need to disable first for remove those] .168.210.210.168.168.11: 192.168. Do the same test for far-end.168.10.210. Example From Command prompt ping 192.11 Subnet mask: 255.11(Opposite End IP address) Step-2: Assign IP address on far-end PC (not Mandatory could be assign any valid IP) IP address: 192.168.210.11: 192.210.210.11: 192. if it replies then IP assignment and connectivity is OK.  Step-3: How to ping-in your PC go to StartRun write “CMD”OK Ping 192. MEP.11 –t [If your PC IP is 192.168.210.210.210.168.11: 192.0 Gateway: 192.11: 192.  Note: After completion the test.Acceptance guideline ipasolink 200 Result must show TTL =254 for your testing MAC address.210.0 Gateway: 192.168.11: 192.11: 192.11 –t” and vice versa. 3) ETHERNET Port Performance TEST.168.210.255.210. Make sure that LT result is showing the same VLAN ID/MEP ID/MEG ID and MEG LEVEL which are configured in earlier steps.10(Opposite End IP address) Then try to ping the far-end PC.168.255.168.10 with 32 bytes of data: Reply Reply Reply Reply Reply Reply Reply Reply from from from from from from from from 192.168.210.168.168.168. 11: 192.210.11: bytes=32 bytes=32 bytes=32 bytes=32 bytes=32 bytes=32 bytes=32 bytes=32 bytes=32 time<1ms time<1ms time<1ms time<1ms time<1ms time<1ms time<1ms time<1ms time<1ms TTL=64 TTL=64 TTL=64 TTL=64 TTL=64 TTL=64 TTL=64 TTL=64 TTL=64 ipasolink 200 Ping statistics for 192.210.210. Average = 0ms Note: If you got the above sample test result.11: 192.168.168.210.168.210.11: Packets: Sent = 17.168. Lost = 0(sent=receive) Approximate round trip times in milli-seconds: Minimum = 0ms. it means your IP assignment as well as iPaso200 ETHERNET port setting is correct and Overall Ethernet performance via this port ok.11: 192.] .168. Received = 17.210.168.168.11: 192.210.11: 192.11: 192.11: 192.168.11: 192.Acceptance guideline Reply Reply Reply Reply Reply Reply Reply Reply Reply from from from from from from from from from 192.210. Maximum = 0ms.210.168.210.168.
Copyright © 2024 DOKUMEN.SITE Inc.