Home
Login
Register
Search
Home
ABB Oil Distribution Transformer Catalogue
ABB Oil Distribution Transformer Catalogue
March 26, 2018 | Author: Sofarsogoodsowhat JgnNe | Category:
Transformer
,
Electric Power Distribution
,
Insulator (Electricity)
,
Inductor
,
Electromagnetism
DOWNLOAD
Share
Report this link
Comments
Description
Distribution TransformersThe most comprehensive range of solutions for distribution transformer applications Data included in this catalogue are subjected to changes without any notice. The most comprehensive range of solutions for distribution transformer applications Even our standard solutions are special In almost every place where people live and work you will find at least one transformer. But as long as it keeps working and supplying power to the escalator in the department store, the hotel lift, the office computer, the oven in the local bakery, the farm machinery or the petrochemical plant nobody gives it a second thought. However, transformers are one of the most important units in every production process. Without them the core activities of nearly every business and factory would come to a standstill – with serious financial consequences. After nearly 100 years in the development and manufacture of transformers we are well aware of this dependence. This is why, we never compromise on the performance, security or reliability of our products. Nor on design, materials, manufacturing methods, environmental protection or recycling. Our objective is to support you and to add value to your activities, by offering a comprehensive range of top quality transformers. We also provide top class service and support. With this approach we can tailor the most appropriate technical solution to every problem. A high quality solution with better service and support, better for the environment and yet with greater availability and a lower total cost of ownership than our competitors. All over the world, in underground railways, in amusement parks and in every kind of factory you will find ABB transformers at work. In the following pages ABB invites you to find the optimal solution to your application and to see with your own eyes that even our standard solutions are special. 4 ABB Power Technology Products Product Index Small Distribution Transformers page 11 Oil Type Transformers Special Applications Dry Type Transformers Medium Distribution Transformers page 16 Large Distribution Transformers page 19 Single Phase Transformers page 24 Vacuum Cast Coil Transformers page 29 RESIBLOC® Resin-Encapsulated Transformers page 36 Pad Mounted Transformers page 43 Transformers for Variable Speed Drives page 44 Reactors page 47 Boosterformers™ page 49 ABB Power Technology Products 5 Oil Type Transformers Single-phase and three-phase transformers for the range above 16 kVA and up to 72. Special Applications Pad Mounted Transformers: These units are delivered from the factory in tamper-resistant housings designed to prevent access by unauthorised personnel. They provide high level security and are found in hospitals and other public areas. high humidity or extreme climates. commercial buildings and industrial complexes. reliable and durable. This construction provides great strength and flexible design dimensions. They can be supplied as oil type or dry type. in ships.5 kV and secondary operating voltages up to 36 kV. RESIBLOC® transformers have a special resin-encapsulated construction which is unique to ABB. Dry Type Transformers For the range 30 kVA to 30 MVA with primary operating voltages up to 41. on oil platforms. A correctly designed installation will provide impressive savings from reduced down-time. The unique core and coil designs and the use of special turn insulating materials make these units extremely compact. underground railways and mines. They are extremely tough and resilient and are resistant to the effects of vibration. substations and networks. low-speed equipment such as mine hoists. Converter transformers can be used for the variable speed drives of high-load. Reactors: Single-phase and/or three phase for a wide range of applications. They should be considered for earthquake prone areas. These units are designed for operation in difficult conditions – environmental contamination. which is biodegradable. also for pad-mounts. They are used in public distribution systems. extended equipment life and lower power costs. rolling mills and ship propulsion systems. A wide range of transformer fluids is available including BIOTEMP™. less flammable and thermally efficient – ideal for densely populated or environmentally sensitive areas. Transformers for variable speed drives: These units can be supplied with primary power ratings up to 30 MVA. fire hazard.5 kV. Boosterformers™: Boosterformers™ are used in order to improve the function of electrical power systems and protect the environment from dangerous stray currents near an electrical railway. 6 ABB Power Technology Products . These units are designed for power centres. > 250 ≤ 2000 up to 36 Used for indoor or outdoor applications.5 ≤ 100 up to 36 Dry Type Transformers Product MVA Primary Voltage (kV) up to 36 Features Vacuum Cast Coil ≤ 30 Provides the ultimate in winding protection for the most demanding applications when efficiency and reliability are critical. can be provided with on-load tap changers or off-load tap changers. Provides the ultimate resistance to mechanical stress associated with heat and short circuit conditions in the most demanding applications. RESIBLOC® Resinencapsulated ≤ 30 up to 41. can be provided with on-load tap changers or off-load tap changers. Small distribution transformers for pole mounting. can be provided with off-load tap changers. > 2000 up to 72.Product Selection Guide Oil Type Transformers Product kVA ≤ 250 Primary Voltage (kV) up to 36 Features Small Distribution Transformers Medium Distribution Transformers Large Distribution Transformers Single Phase Transformers Used for indoor or outdoor applications. Used for indoor or outdoor applications.5 Transformers for Special Applications Product Pad Mounted Transformers Transformers for Variable Speed Drives Reactors Boosterformers™ ABB Power Technology Products 7 . gauges. For heavily polluted environmental conditions ABB offers special paint finish cycles in epoxycoating for the protection of metallic components and electrical equipment. Used for indoor or outdoor applications. durability and reduced dimensions required for their application in utilities. Selection Guide Product kVA Primary Voltage (kV) up to 36 Features Small Distribution Transformers Medium Distribution Transformers ≤ 250 Used for indoor or outdoor applications. can be provided with on-load tap changers or off-load tap changers. Transformers are an integral part of power systems with applications in industrial facilities. alarm packages. networks and padmounts.Oil Type Transformers ABB Power Technology Products . ABB oil type transformers are manufactured in accordance with the international quality standards ISO 9001 and ISO 14001.5 Single Phase Transformers ≤ 100 up to 36 8 . substations.Oil Type Transformers ABB’s liquid filled Power Distribution Transformers range from 16 kVA upwards. can be provided with on-load tap changers or off-load tap changers. fans and special signs and tags. Standard features Standard features include aluminium or copper windings. epoxy or porcelain bushings. industrial installations and public distribution.5 kV. The core and coil design is a unique characteristic of ABB’s oil type transformers. Used for indoor or outdoor applications. ABB supplies the widest range of power distribution transformers. Small distribution transformers for pole mounting. including specific designs for power centres. can be provided with off-load tap changers. > 250 ≤ 2000 up to 36 Large Distribution Transformers > 2000 up to 72. which generate the reliability. commercial buildings and utility transmission and distribution networks. with primary voltages up to 72. which is a tough. Generous oil ducts extend along the height of the coil to provide cooling in the winding. is a thermally upgraded kraft paper. Layer insulation The Insuldur system of chemical stabilisers thermally upgrades the cellulose insulating materials to permit 12% higher load capacity. diamond epoxy bonds help assure free oil flow through the winding. abrasion resistance and thermal and chemical stability. The large areas presented by the layer-type winding result in a low ground capacity. sound levels by up to 3 dB and iron losses by up to 10%. By minimising this imbalance vertical forces are correspondingly reduced. thus making the design stronger under short circuit stresses. The staggered.Construction features Core The core is a series of laminations made from high-quality. Dimensional changes in the insulating materials are minimised to ensure a tighter structure. The core efficiently fills the opening in the coil. The layer insulation is coated with a diamond pattern of B-stage epoxy adhesive. DuraBIL® maintains its dimensional stability and the coil’s structural integrity. high-impulsestrength coil is the result. Some design considerations may require the use of traditional crepe paper or Nomex® tape as turn insulation. Since DuraBIL® is chemically stable. The rectangular shape of the core can be more uniformly and firmly supported to prevent movement of the laminations so as to improve sound level characteristics. The high to low insulation is fitted over the low voltage winding and the wire of the strap wound high voltage is wound directly over the low voltage to form a high strength coil assembly. which cures during processing to form a high strength bond. Insuldur. The stacked core provides a superior flux path by utilising a step-lap that joins the core legs to the top and bottom yokes. utilise DuraBIL®. A compact. The Insuldur system allows a unit rated at 55°C to be operated at a 10°C higher temperature with a 12% increase in kVA capacity. The effective support for the core together with a step-lap joint have reduced existing currents by up to 40%. The process is closely controlled and monitored to ensure a continuous. it does not degrade or contaminate the transformer fluid with moisture. Unbalanced ampere-turns create forces during short circuits that push the high voltage and low voltage coils apart vertically. Turn insulation ABB power distribution transformers are designed to meet specific performance criteria defined by the customer. This bond keeps the windings from moving during operation or under short circuit stresses.Oil Type Transformers . flexible and inert turn insulation. Coils The coil features a low voltage rectangular wire or sheet conductor extending along the full height of the coil. The result is greater strength and coil integrity throughout the life of the transformer. As a result. The result is a compact turn insulation with superior characteristics including adhesion. The short yoke between the legs of the core reduces the external flow between the active leg core material. which gives a nearly straight line surge distribution throughout the winding. ABB Power Technology Products 9 . however. leaving a minimum of unused space. flexibility. Accurately located taps and a large winding cross section keep unbalanced ampere-turns to a minimum. Most designs. Chemical stabilisers delay insulation breakdown under elevated temperature conditions. grain-oriented silicon steel. resulting in an increase in efficiency. The layer to layer insulation. uniform coating. It reduces the most prevalent cause of transformer failure – deterioration of turn insulation. Insuldur can be used with all fluids offered by ABB for small power transformers. DuraBIL® is a single layer of epoxy powder deposited electrostatically and baked on a strap conductor. Mineral oil is usually recommended for outdoor applications. is offered with most ratings. MIDEL and BIOTEMP™. Transformers designed with less flammable fluids can be used to meet specific requirements of non-flammability. laboratories. environmentally friendly dielectric fluid that is also classified as less flammable. 10 . fully biodegradable.Transformer fluids A choice of transformer fluids. BIOTEMP™ has been shown to be 97% biodegradable within 21 days by underwriters. silicone. Silicone and R-Temp are classified as less flammable fluids and are used when flammability is a concern. including oil.Oil Type Transformers ABB Power Technology Products . BIOTEMP™ is suitable for indoor applications and in areas of high environmental sensitivity where any insulating fluid spill would require expensive clean-up procedures. BIOTEMP™ is a new. The mounted core is clamped down in order to reduce vibrations and minimise noise levels.Off-circuit tap changer in 5 positions .Corrugating tanks . The mechanism can also be padlocked during normal transformer operation. are connected to the off-circuit tap changer located horizontally between the yoke and the tank cover.Small Distribution Transformers (≤ 250 kVA ) Construction features Description ABB Distribution Transformers manufactures three phase oil type small distribution transformers within the range up to 250 kVA and 36 kV. grain oriented silicon iron sheets insulated with carlite.Drain cock . It is manufactured with first-rate.Thermometer pocket in accordance with DIN 42554 (standard from 100 kVA) .Rating plate .5%) of the HV winding.Lifting lugs . The transformers are adaptable for pole mounting or assembly in substations. Standard features Hermetically sealed transformers completely filled with oil: .Inhibited oil Transformers can also be manufactured with conservators. The design prevents setting the off-circuit tap changer to intermediate positions.Small Distribution Transformers . the complete columns are manufactured to withstand short circuit stresses. Windings The windings are made of either copper or aluminium.Filling plug . Furthermore.High and low voltage bushings in accordance with DIN 42531 and DIN 42530 . Other product types with different dimensions and technical specifications can be designed and manufactured on request. ABB Power Technology Products 11 .Earthing terminals . Core The magnetic circuit is of the three column type with mitred joints. Off-circuit tap changer The tappings (±2 x 2. they are insulated with either pure cellulose or double enamel. The handle is located on the cover and should be operated when the transformer is deactivated. The bottom plate.C. The metal parts are carefully sandblasted. free. The painting system is a single coat one pack epoxy.Total enclosure on cover over HV and LV bushings Testing The transformers are manufactured in accordance with ISO 9001 and ISO 14001.Thermometer pocket in accordance with DIN 42554 (standard from 100 kVA) . The top coat is RAL 7033 or customized.T.Dielectric tests Upon request. Options and accessories .Insulating oil The mineral oil with its electrical and chemical characteristics is in compliance with the IEC Standards and is P. The hot-dip galvanizing is 70 µm minimum. bushings.Sparking gaps .C.Pressure relief device . The thermometer pockets.Integrated pole brackets on tank .Measurement of the voltage ratio and check of the vector group . The cover is bolted to the tank frame. The routine tests are: .Cable boxes . The welds are tested for oil tightness.Measurement of the impedance voltage and measurement of load losses . The undercarriage is welded to the bottom plate and the rollers are suitable for either longitudinal or transverse movements.Off-circuit tap changer with 3 or 7 positions . side and frames are of a welded construction. and P. tap switch drive and lifting lugs are fitted on the tank cover.Oil level indicator for hermetically sealed transformers . At the end of the manufacturing process the transformers are individually tested in accordance with the IEC Standards. 12 . Painting and surface treatment Transformers are either hot-dip galvanized or painted.Dial type thermometer with two contacts .Bi-directional rollers .Max thermometer . witnessed type/special tests can be carried out.Plug-in bushings on HV .B.Measurement of the winding resistance .Skid base .Small Distribution Transformers ABB Power Technology Products .Measurement of no load losses and no load current . Tank and cover The sides of the tank are made of corrugated cooling surfaces. 5 4 4 4 4 4.5 4.2 4 4 3.5 4.5 4.6 4 4.5 4 4 4.Oil Type/Small Distribution Transformers No-Load Loss (W) Wheel base (mm) 0 420 420 0 670 0 0 0 420 420 420 420 420 420 0 0 420 520 0 0 0 0 0 0 520 520 670 670 520 520 520 0 0 0 0 0 0 520 520 520 520 520 1070 520 520 30 40 40 50 50 50 50 50 50 50 50 50 50 50 63 63 63 63 63 63 63 100 100 100 100 100 100 100 100 100 100 100 100 100 160 160 160 160 160 160 160 160 160 200 200 200 200 200 200 250 250 250 250 250 250 250 250 250 250 250 250 20500 0 15750 0 15750 0 10000 0 10000 0 10000 0 20500 0 16800 0 20000 0 22000 0 11000 0 20000 0 10000 0 20000 0 22000 0 22000 0 15750 0 16800 0 15750 0 21000 0 15750 0 10000 0 10000 0 20500 0 10500 0 16800 0 21000 0 20000 0 10500 0 21000 0 11000 0 22000 0 10500 0 22000 0 22000 0 15750 0 10000 0 20000 0 20000 0 16800 0 15750 0 15000 0 10000 0 20500 0 10500 0 22000 11000 11000 0 22000 0 10500 0 22000 0 22000 0 10000 0 22000 0 10000 0 20000 0 15750 0 15750 0 25000 0 16800 0 22000 0 21000 0 410 400 400 400 400 400 410 420 400 420 420 400 400 400 420 420 400 420 400 400 400 400 400 410 400 420 400 400 400 400 420 420 420 420 420 400 400 400 400 420 400 400 400 410 400 420 420 420 400 420 420 400 420 400 400 400 400 400 420 420 400 Yzn11 Yzn5 Yzn5 Yzn5 Yzn5 Yzn5 Dyn11 Dyn5 Yzn11 Dyn11 Dyn11 Yzn5 Dyn5 Yzn5 Yzn5 Yzn5 Yzn5 Dyn5 Yzn5 Yzn5 Yzn5 Yzn5 Yzn5 Dyn11 Dyn11 Dyn5 Yzn5 Dyn11 Dyn11 Dyn11 Dyn11 Dyn11 Dyn5 Dyn11 Dyn5 Yzn5 Dyn11 Dyn11 Dyn11 Dyn5 Yzn5 Dyn11 Dyn11 Dyn11 Dyn11 Dyn11 Dyn11 Dyn11 Dyn11 Dyn5 Dyn5 Dyn5 Dyn5 Dyn5 Dyn5 Dyn5 Dyn5 Dyn11 Dyn5 Dyn1 Dyn5 4 4.8 4 4.6 4 4 3.8 3.5 4 4 4 3.5 100 90 130 125 190 125 140 125 190 115 115 125 115 125 190 160 130 130 180 180 180 320 210 220 215 180 240 500 165 165 185 185 165 245 375 280 460 460 300 265 300 650 300 420 320 370 365 370 360 425 440 425 530 425 425 360 460 780 345 290 460 v 585 900 900 1100 1100 875 885 900 1100 940 920 875 850 1350 1350 1350 1130 950 1130 1280 1160 1750 1750 1485 1700 11800 1720 1700 1700 1760 1520 1525 1240 1550 2350 2200 2350 2350 2350 1750 2350 2400 2000 2295 2450 2280 2225 2250 2700 3250 2750 3250 3250 2750 3250 2350 3200 3500 2230 5000 3260 0 48 48 47 50 47 0 51 44 48 48 47 50 47 51 48 48 51 48 48 48 50 49 0 48 52 49 48 48 48 48 48 54 48 57 50 50 50 50 53 50 48 50 0 53 53 53 53 53 55 55 50 60 50 50 51 51 52 55 46 51 395 340 330 375 365 425 440 390 465 415 370 375 425 350 465 465 430 460 430 460 470 585 670 510 490 730 585 800 535 580 510 545 600 540 765 830 840 880 880 890 1000 900 870 995 870 870 840 940 840 1180 1250 1110 1180 1160 1130 1010 1030 1245 1450 1120 945 115 90 90 90 90 100 125 120 125 110 90 95 115 90 105 105 100 110 100 100 100 130 145 120 110 160 120 0 110 140 95 125 135 150 165 165 180 205 205 190 220 0 180 235 180 180 160 200 200 260 260 205 260 200 220 200 205 300 270 0 175 840 790 790 760 760 820 840 820 870 810 760 860 800 790 1280 1280 945 820 945 830 830 820 1120 850 870 930 870 950 870 920 860 850 920 920 1000 970 1040 1000 1000 1010 1080 1100 1040 1080 950 950 1030 1020 950 1100 1100 1300 1100 1000 1060 1150 1040 1210 1150 1450 990 770 580 580 650 650 625 770 645 650 585 600 600 480 580 630 630 665 645 665 680 680 775 725 610 500 645 670 650 500 520 600 610 540 520 720 805 675 700 700 645 790 670 675 730 625 625 655 700 625 780 800 750 780 700 760 975 950 860 715 900 720 1005 970 970 885 885 885 1055 1010 1400 1040 945 975 1200 955 1650 1650 970 1030 970 1150 1150 1030 1090 1080 1170 1200 1200 1270 1220 1295 1070 1115 1220 1245 1400 1110 1140 1210 1210 1180 1290 1350 1140 1250 1345 1495 1170 1245 1295 1500 1600 1190 1500 1220 1190 1260 1185 1605 1310 1500 1340 Please note that this table only shows a small sample of all productdesigns and ratings we supply.Small Distribution Transformers Tank description v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v Total weight (kg) Noise level (dB) Impedance (%) Load Loss (W) Oil weight (kg) Vector Group Length (mm) Height (mm) Width (mm) HV1 (V) HV2 (V) LV1 (V) kVA .5 4.8 4 4 4 4 4 4 4.5 4 4 4 4 4 4 4 4 4 3.5 4 4 4. Hermetically sealed with corrugated tank q Corrugated tank with conservator ABB Power Technology Products 13 .5 4 4 4 3.7 4 4 4 4.4 3.5 4 4.5 4. passenger safety comes before all else. ABB´s Small Distribution Transformers ensure that runaway lights. .Passenger safety in focus For airports such as Sweden´s Hultsfreds Airport. radio beacons and air traffic control communications all function reliably. . Off-circuit tap changer The off-circuit tap changer is of a 5-position type connected on the High Voltage side with a handle located on the cover.Rating plate Additionally.Medium Distribution Transformers ABB Power Technology Products . The tap changer should be operated only when the transformer is deactivated.Oil-level indicator .Oil filling plug on the cover .Undercarriage with bi-directional rollers . The winding construction is characterised by high dielectric strength with high resistance. ≤ 2000 kVA ) Standard features Hermetically sealed.Sparking gaps for voltages 15 kV and above . to atmospheric surges and to the effects of short-circuits.Max thermometer .Corrugated tank . (Rated power <1000 kVA): . The transformers in standard versions are designed for use in moderate climates and can be installed both outdoors and indoors. cold-rolled silicon steel laminations with low losses.Buchholz relay . for transformers with conservator (Rated power ≥1000 kVA): . enamel insulated. mainly in metropolitan areas and for industrial applications. 16 . The High Voltage windings are wound either with round. The loading is in accordance with IEC 354. They also compensate for the changes in the oil volume during operation. MDT transformers are hermetically sealed (the tank is completely filled with oil) or equipped with oil conservator. The Low Voltage windings are wound with shaped.Oil filling plug on the conservator . paper insulated wire. Both types are equipped with flexible corrugated tank walls enabling sufficient cooling of the transformer. Neutral points of the Low Voltage windings are brought to the tank cover.The two lifting lugs on the cover are made for lifting the transformer or its removable part . An advantage of the hermetically sealed transformers is that the oil is never in contact with the atmosphere thus avoiding periodic oil analysis.Off-circuit tap changer handle . Construction features Description MDT transformers are used to step down threephase high voltage to low voltage for power distribution.Conservator Core The cores of the transformers are made of grain-oriented magnetic.Earthing terminals .Dehydrating breather . or shaped. paper insulated wire or foil. Windings The windings of the transformers are made of high grade electrolytic copper or aluminium.Magnetic oil-level indicator .Medium Distribution Transformers (> 250 kVA.Oil drain valve . -3 x 2.301–2.Cable boxes . Options and accessories .Additional thermometer pocket . and P.High Voltages 3. Painting and surface treatment All metal parts are carefully sandblasted.Low Voltages 100 . when the tropical storm known as Alison hit Houston.Vector group: Dy.Pressure relief valve with or without contacts .Dual voltage transformer Specifications .000 . The transformer undercarriage is provided with bidirectional rollers turnable by π/2 rad (90°) to allow longitudinal and transverse movement on flat surfaces. The painting is made with a single coat of onepack epoxy paint.C. 60 Hz optional . On 26 June. Yd . Dd. and Hermann Hospital in Texas experienced one in June 2001.Medium Distribution Transformers . ±2 x 5%.Air insulated housings .DGPT2 control device .Impedance voltage: 4-7% . If requested a hotdip galvanized corrugated steel tank can be provided. Just 60 hours later. Yz. +2. PN etc.000 kVA.Plug-in bushings . This helped to ease the consequences of the disaster.5% Hard Rain Power failure is a nightmare scenario for any healthcare institution. already known in history books as “the rain of terror”. Tank and cover The cover is bolted to the tank frame.Spark gap meter .C.Voltage regulation: ±2 x 2. the new transformer was designed. .Galvanized tank .750 V .B. The finishing paint is made with two or three coats. UNE.Tap changer with more than five positions . the hospital ordered a 1000 kVA Distribution Transformer from ABB.000 V .5%. ABB Power Technology Products 17 .5 %. 65°C maximum windings temperature rise .T. BS. three-phase.Insulating oil The mineral oil with its electrical and chemical characteristics complies with the IEC Standards and is P.Standards: IEC.Dial type thermometer with two contacts .15. built and dispatched. Yy. free.35.50 Hz standard. DIN. 4 4 4.5 6 6 4.6 4 6 6 4.5 6 5.Medium Distribution Transformers ABB Power Technology Products Tank description Total weight (kg) Noise level (dB) Impedance (%) Load Loss (W) Oil weight (kg) Vector Group Length (mm) Height (mm) Width (mm) HV1 (V) HV2 (V) LV1 (V) kVA .3 6 7.19 6 5.4 6 5.7 6 6 6 6 980 1050 1050 1050 620 750 570 475 710 730 710 500 1450 840 800 720 800 1700 1030 1940 1400 1600 1300 1300 1300 2360 1320 2600 1460 2400 1780 1700 1580 3200 2200 2100 3200 v 4130 4200 4200 4200 5000 4600 4100 3480 5000 5500 4600 4000 5800 7000 5600 6100 8700 8500 6800 8200 8500 9700 10200 10200 12200 13500 16900 13000 13400 14000 16700 16000 13500 21000 20100 19000 21000 64 53 53 53 50 63 52 0 0 50 0 0 53 52 60 54 54 68 0 53 56 0 56 56 0 70 0 65 0 0 0 58 0 71 0 0 71 1550 1300 1300 1300 2050 1560 1520 1730 1750 1660 1690 2200 1750 2600 2500 2035 2040 2650 2300 2200 2320 3100 2800 2790 2420 3550 4140 3600 3000 4000 3320 3995 3680 5000 4020 4710 5000 370 0 0 0 0 340 320 320 320 365 320 350 0 0 510 400 445 525 380 0 530 0 550 550 470 760 1190 0 580 0 680 820 775 1100 850 900 1100 1300 1240 1240 1240 1300 1300 1210 1140 1140 1300 1140 1470 1450 1450 1400 1270 1530 1700 1520 1630 1400 1800 1970 1970 1670 2000 2345 1860 1830 2000 1890 2100 1910 2250 2010 2330 2250 900 800 800 800 900 900 850 820 880 920 880 850 970 900 1050 900 950 950 900 1080 1050 1050 980 980 1030 1100 1370 1250 1150 1100 1170 1130 1120 1300 1220 1360 1300 1700 1400 1400 1400 1800 1600 1480 1495 1600 1860 1450 1560 1500 1800 1700 1600 1690 2100 1700 1600 1890 1860 1980 1980 1590 2250 2310 1640 1720 1900 1860 2250 1970 2350 1910 2320 2350 v v v v v v v v v v v v v v v v v v v q v v q q v v q q v v v q v q v q q Please note that this table only shows a small sample of all productdesigns and ratings we supply.Oil Type/Medium Distribution Transformers No-Load Loss (W) Wheel base (mm) 670 670 670 670 670 670 670 0 0 0 0 670 670 670 670 670 0 670 820 820 820 0 820 820 820 0 820 0 820 0 1070 0 1070 1070 315 315 315 315 400 400 400 400 500 500 500 500 500 630 630 630 630 800 800 800 800 1000 1000 1000 1000 1250 1250 1250 1250 1600 1600 1600 1600 2000 2000 2000 2000 26000 20000 15000 10000 35000 21000 15750 10500 22000 20000 11000 10000 10000 35000 22000 15750 10000 26000 21000 15000 10000 35000 21000 15750 10000 26000 20000 15000 10500 35000 20000 15750 10000 30000 20000 15750 10000 0 8000 0 0 0 0 0 0 11000 0 0 0 0 0 0 0 0 0 0 10000 0 0 0 0 0 0 15000 10000 0 0 0 0 0 0 0 0 0 400 400 400 400 400 420 400 420 420 400 420 690 400 400 420 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 690 6300 400 400 6300 Dyn11 Dyn11 Dyn11 Dyn11 Dyn1 Dyn5 Dyn5 Dyn5 Dyn11 Dyn5 Dyn11 Dyn5 Dyn11 Dyn1 Dyn5 Dyn5 Dyn5 Dyn11 Dyn11 Dyn11 Dyn5 Dyn1 Dyn5 Dyn5 Yyn0 Dyn11 D(D)yn11 Dyn11 Dyn11 Dyn1 Yyn0 Dyn5 Dyn5 Dyn5 Yyn0 Dyn5 Dyn5 4 4 4 4 6 4 4.8 5 6 6 6 6 5.5 4 4. Hermetically sealed with corrugated tank q Corrugated tank with conservator 18 .5 4. SS 4270101 etc. The cross section of the leg is circular. Windings The material of the windings is either copper or aluminum. long life and reliability.5 kV ) Construction features Description ABB has been manufacturing transformers for almost a hundred years. The joints between the leg and yoke are mitred at 45° and interleaved. They are also in compliance with several national standards e. ABB Power Technology Products 19 . conventional type provided with an oil conservator. Two types of transformers are manufactured: . guarantees high quality.Transformers with off-load tap changer . Standard features The transformers are manufactured and tested in accordance with the IEC Publication 76.Large Distribution Transformers .g. The windings are made of paper insulated rectangular wire in the form of multilayer. This long experience combined with research and development.position) corresponds with the lowest ratio which consequently gives the highest voltage on the Low Voltage side. Position 5 of the tap-changer (. with its handle located on the cover. Construction features The transformers are of the breathing. The on-load tap-changer and bushings have been chosen so as not to limit the overload capability. up to 72.Large Distribution Transformers (> 2000 kVA. When changing the tap position the transformer has to be un-energized. The cooling methods are ONAN or ONAN/ONAF. BS 171. The production is based on the development and research carried out in the design department and at the ABB Research Centre in close cooperation with our customers. Transformers having dual primary (or secondary) voltages are usually equipped with a selector switch with the handle on the cover.Transformers with on-load tap changer Core The three legged bolt-less core is constructed of grain oriented steel laminations. disc or helical windings. Position 1 of the tap-changer (+ position) corresponds with the highest ratio. which gives the lowest voltage on the Low Voltage side. Off-load tap-changer The transformers are normally equipped with a 5-position off-load tap-changer on the High Voltage side. Transformers provided with on-load tap-changer usually have a separate tap winding. The transformers can be overloaded in accordance with IEC Publications 354 (1972). VDE 0532. Corrugated tanks are flow painted with alkyd primer and acrylic finish to a total thickness of 80 µm. The tap-changer is equipped with a protective relay.Oil conservator with oil level indicator . The bushings comply with IEC 137.Buchholz relay . Insulating oil The mineral oil used in the transformers complies with IEC 296 and several national standards. Transformers up to 5 MVA can be supplied with a compact tank with corrugated cooling fins. The tapchanger works as a selector switch combining the features of a diverter switch and a tap selector. The on-load tap-changer is provided with a motor drive mechanism for remote and local control.Bushings . Normally the motor drive is three-phase and the control and the heating circuits are for single phase AC supply. The selector switch is of the high-speed spring operated type with resistive transition impedances. 60 µm. When re-quested. The terminals can be provided with an air insulated enclosure.Top oil thermometer Additional accessories can be fitted in accordance with the customer’s specifications. The finishing is carried out by applying a two-pack polyurethane paint to a total thickness of 180 µm.Large Distribution Transformers ABB Power Technology Products .Oil sampling device . Alternatively the transformers can be provided with plug-in bushings. The conservator and the bottom part of the tank are painted internally. DC circuits can be supplied. External surfaces are painted immediately after pretreatment with a two-pack epoxy primer coat. where the windings are heated electrically while simultaneously the air is evacuated from the oven. Options and accessories The transformers are fitted with the following standard accessories: .Lifting lugs . 30 µm. The selector switch can be lifted for inspection and the oil in the compartment can be changed separately. 20 .Rating plate . The external surfaces of the radiators are hot dip galvanized to a thickness of approx. In this way moisture and gases are effectively removed from the windings and oil.Filling and drain valves . the cover and oil conservator are sandblasted.Jacking pads (radiator tanks) . Painting and surface treatment Prior to the painting of the tank.On-load tap changer The on-load tap-changer is mounted on the cover of the main transformer tank. The colour of the paint is RAL6013 (rush green). The oil slows down the ageing process.Earthing terminals . Tank The transformer tank is usually of the rigid type provided with removable radiators connected to the tank by means of a shut-off valve. Bushing insulators can be changed without opening the transformer. The transformers are individually tested according to IEC standards. On request. reaching an absolute pressure of 1 mbar. The inside of the transformer tank is painted with a two-pack epoxy primer to a thickness of approx. The enclosure can be on the primary and/or on the secondary side and may be constructed for cable or bus duct connection.Silica-gel breather . Testing All transformers are manufactured according to the ISO 9001 Quality System. The transformer is filled with oil while it is still under vacuum. Bushings The bushings are of a solid porcelain type and located on the cover. Vacuum treatment Drying and vacuum treatment takes place in a special oven. Transformers with off-load tap changers can be delivered filled with silicone oil or MIDEL fluid if requested. the tank can be made vacuum proof. The selector switch is located in a separate oil compartment which is connected to its own conservator. 2.5. Routine tests 1. short-circuit impedance and load loss 1.7 Tests onload tap-changer 3.3 Short circuit test 3.1.8 Leakage test for transformer tank ABB Power Technology Products 21 . Type tests 2.2.1.5 Measurement of harmonics in the noload current 3.Large Distribution Transformers .6 Tests of auxilary equipment and wiring 3.5 Dielectric tests: 1.2 Dielectric tests: 2.1 Measurement of winding resistance 1.2 Measurement of voltage ratio and testing of voltage vector relationship 1.2 Chopped wave test 3.1 Separate source voltage withstand test 1.2 Induced overvoltage withstand test Witness type/special tests can be carried out on request.4 Measurement of sound level 3.1.2 Measurement of zero-sequence impedance on three phase transformers 3.4 Measurement of no-load loss and current 1.3 Measurement of impedance voltage. Special tests 3.5.1 PD-test 3.1 Lightning impulse test 3.1 Temperature rise test 2.1 Dielectric tests: 3. Neither Wärtsilä nor their customers would be able to reach their rewards so quickly. And for the rest of us. one of the world’s leading manufacturers of gas and diesel engines for power generation and for off-shore applications would definitely not want to be without our fast deliveries of 8. 22 . Without that speed their greatest sales advantage for diesel power plants would be lost. more money Many of the “Paradise Islands” might not seem so paradisial without electricity.Large Distribution Transformers ABB Power Technology Products . 12 and 16 MVA Large Distribution Transformer units. Wärtsilä NSD.Less time. those islands might no longer seem such idyllic places to visit. 5% ±9x1.67% ±2x2. ABB Power Technology Products 23 .67% Tap-changer No-Load Loss W 3500 3800 4200 4500 4900 5000 6000 6200 7000 7200 8100 8200 Load Loss W 25000 25500 29000 31000 35000 39000 45000 45000 56000 56000 65000 68000 Impedance % 6.Large Distribution Transformers Rated power kVA 2001-5000 2001-5000 5000 and above Primary Voltage kV up to 72.5 BIL.67% ±2x2.15 7.35 7.5% ±9x1.35 8.15 7.15 8.67% ±2x2.5% ±9x1.35 8.5 up to 72.35 8.15 7.67% ±2x2.5 up to 72.35 Total Weight kg 6250 10000 7500 12100 9300 13400 13200 15400 15300 18100 17200 20600 Oil kg 1210 2780 1440 3220 1670 3620 2750 3960 3140 4760 3480 5090 Other product types with different datas and specifications can be supplied on request.35 6. LV kV up to 110 up to 110 up to 110 Tank Description Hermetically sealed Corrugated tank Radiator tank with conservator Large Distribution Transformers Typical datas for 20/10 kV transformer with off-load or on-load tap-changer Rated power kVA 3150 4000 5000 6300 8000 10000 ±2x2.35 6. HV kV up to 350 up to 350 up to 350 Secondary Voltage kV up to 15 up to 15 up to 15 BIL.5% ±9x1.67% ±2x2. Please note that this table only shows a small sample of all productdesigns and ratings we supply.5% ±9x1.35 6.Large Distribution Transformers .5% ±9x1. free breathing construction Standard features for EATS or ANSI can be provided.sealed construction . Internal HT fuses can be fitted.Single Phase Transformers ABB Power Technology Products . ABB’s core design provides optimal efficiency and better mechanical. Ranges 15 kVA to 100 kVA with voltages up to a maximum of 36 kV. as well as for lighting. All units are supplied with hot-dip galvanised tanks including: . These represent an economical option for certain networks. commercial loads. high voltage porcelain bushing(s) with eyebolt terminal or spade terminal . ANSI or DIN bushings.fibreglass reinforced polyester or porcelain low voltage insulators Options and accessories Bushings mounted on lid or on turrets.lifting lugs . IEC or ANSI standards.cover mounted. oil type small distribution transformers for pole mounting.Single Phase Transformers ( ≤ 100 kVA ) Construction features Description ABB Distribution Transformers manufactures single-phase. thermal and electrical performance. industrial and diversified power applications. Can be fitted with acing horns or surge arrestors. Tap-switch or internal link board. Standard and type tests Can be supplied in accordance with IETS. Standard features Two types of transformer are manufactured: . Single or dual ratio. These transformers are designed for the duties normally encountered on electric utility power distribution systems. All units have been type tested according to IEC. They are suitable for serving residential overhead distribution loads. 24 . 2 or 3 view options. with a further 2. single phase distribution transformers were shipped from ABB´s stock to CP&L.Single Phase Transformers . Carolina Power & Light (CP&L) and ABB were prepared.600 transformers shipped 12 days later. ABB Power Technology Products 25 . Within 48 hours.Planning minimised the impact of Dennis and Floyd When the hurricanes Dennis and Floyd struck. 225 pole-type. The Olympics have a bright future RESIBLOC® transformers from ABB will be in the spotlight at the Olympic Games in Sydney. 100. 26 .000 spectators in the grandstands and over a billion people viewing television can count on ABB to make sure everything works faultlessly – from timekeeping to arena lighting.Vacuum Cast Coil Transformers ABB Power Technology Products . designed for the severe conditions present in: . nuclear-powered navy vessels and high-volume industrial process plants. Rectifiers and frequency converters for AC motors. nuclear power plants. ABB’s dry type transformers are virtually maintenance free and are manufactured in accordance with the international quality standards ISO 9001 and ISO 14001. Power plants for auxiliary services and excitation transformer systems. container cranes at seaports. car factories etc. offshore drilling platforms. Applications include high-density office buildings. These transformers meet strict parameters with respect to electrical system demands and functioning in areas with extreme climatic conditions.Chemical processing. such as: hospitals. Dry Type Transformers Product MVA Primary Voltage (kV) up to 36 Features Vacuum Cast Coil ≤ 30 Provides the ultimate in winding protection for the most demanding applications when efficiency and reliability are critical. as well as the European HD464 and HD538.5 Provides the ultimate resistance to mechanical stress associated with heat and short circuit conditions in the most demanding applications. ABB dry type transformers fulfil the requirements of international standards IEC 60726. with primary operating voltages up to 41. customers are increasingly requesting dry type transformers. marine applications. multipurpose cultural centres. ABB Power Technology Products 27 .Dry Type Transformers ABB’s dry type transformers range from 30 kVA to 30 MVA. . ABB dry type transformers are also the most technologically advanced.Dry Type Transformers . underground railways. shopping centres. stations and underground mines in non-classified areas. Applications ABB dry type transformers are most suitable for installations that require a high degree of safety. With the aim of minimising environmental contamination and fire hazards. offshore platforms for oil wells.5 kV and secondary operating voltages up to 36 kV. RESIBLOC® Resinencapsulated ≤ 30 up to 41. offshore drilling platforms.Heavy industrial applications: wind power generation. The steel is precision cut to assure that it will be smooth and burr-free.Dry Type Transformers . This construction allows free current distribution within the axial width of the coil which eliminates the axial forces developed in other types of windings under short circuit conditions. An experienced and dedicated work force ensures quality transformers and customer satisfaction with the product. insulation class 1. The finished core is coated with a corrosion resistant sealant which provides lamination cohesion and environmental protection. During the assembly process each Low Voltage winding is blocked radially and axially against the core using a combination of solid and resilient mounts for sound suppression and thermal expansion compensation. ABB starts with non-ageing highly permeable cold-rolled. the upper and lower yokes are solidly clamped to a sturdy metal frame. Typically. and constructs the core with step-lap mitred joints. are wound using sheet conductors. Magnetic flux densities are kept well below the saturation point. For rigidity and support. ABB’s Low Voltage windings. The step-lap construction further enhances the efficiency of the joint by reducing joint fringing which reduces core losses and exisiting currents. ABB’s winding construction may be either round or oval up to 2500 kVA. All possible steps are taken to prevent local circulating currents and to avoid built-in bending stresses. Windings ABB’s windings construction depends on operating voltage. The core is designed and built to provide the lowest possible losses from the effects of magnetic hysteresis and eddy currents.1 kV. grain-oriented silicon steel. basic impulse level and current capacity of the individual winding. Windings on transformers with a rating greater than 2500 kVA are generally round. 28 . The mitred core joint allows efficient flux transfer along natural grain lines between the core legs and yoke.Standard features Core ABB’s dry type transformers utilise a step-lap mitred core construction to ensure optimum performance and minimum sound levels. The emission of toxic substances and fumes is minimised. The use of cast resin.Dual primary-secondary voltage .Cast coil LV windings . They are the ideal transformers for operation in environments with a humidity higher than 75% as well as at temperatures lower than -25°C.Increased basic impulse levels .5% - Provisions for lifting core and coil assembly Rating plate Temperature control device Earthing terminals Base equipped with bidirectional rollers or designed for skidding Options and accessories Design options: .Air-filled terminal chambers .Other designs available on request Accessories .155°C insulation system and 100°C average temperature rise .Four full capacity taps on HV winding rated ± 2 x 2.Loss optimised designs . they are selfextinguishing and in the event of a breakdown there is no risk of leakage of flammable or contaminating substances. combined with our latest manufacturing technique allows us to build a stronger compact transformer capable of withstanding severe rolling and vibration.Plug-in terminals (quick connectors) 29 .Aluminium windings.Casting process utilises high performance filled epoxy .Three-phase electronic temperature monitor . Customers demand dry type transformers more frequently in order to minimise environmental contamination and fire hazard. They do not require any special civil works prior to installation and due to the particular design they can be repaired on site.Anti vibration pads .Forced cooling package with three-phase electronic temperature monitor .Vacuum Cast Coil Transformers . Vacuum cast coil transformers are virtually maintenance free. Vacuum cast coil transformers are moistureproof.Optional ventilated enclosure with removable front and rear panels (IP20 to IP65) .Retrofit designs .Copper windings . LV windings pre-impregnated . suitable for operation in humid or heavily polluted environments.80°C average temperature rise (or other according to requirement) .Step-lap mitered core .Vacuum Cast Coil Transformers (≤ 30 MVA ) Construction features Description ABB vacuum cast coil transformers range from 50 kVA up to 30 MVA with primary operating voltages up to 36 kV and secondary operating voltage up to 6 kV.HV coils vacuum cast in epoxy resin. copper optional . ABB vacuum cast coil transformers are manufactured in accordance with the international quality standard ISO 9001. Standard features . These transformers are not flammable.Special paint colours .Electrostatic screen . Cenelec losses Highest voltage for equipment Rated power kVA 50 100 160 250 315 400 500 630 800 1000 1250 1600 2000 2500 12 kV Load loss at 75ºC W 1230 1760 2380 3080 3780 4310 5630 6690 8010 8900 11130 12460 16200 18900 AC 28 kV No-load loss at 100% Ur W 350 440 610 820 1100 1150 1350 1370 1800 2000 2500 2800 3600 4300 LI 75 kV Short-circuit impedance % 4 4 4 4 4 4 6 6 6 6 6 6 6 6 Load loss at 120 ºC W 1400 2000 2700 3500 4300 4900 6400 7600 9000 10000 12500 14000 18000 21000 Sound power level dB 58 59 62 65 66 68 69 70 71 73 74 76 78 81 AC: Power frequency withstand voltage LI: Lightning impulse withstand voltage.Impulse test withstands voltage up to 200 kV .Light transmission factor of fumes >60% Electrical and mechanical design .Resistance of all windings .Primary Lightning impulse voltage: Withstands up to 170 kV .Minimum dust accumulation Partial discharge tests .Routine test for partial discharge .Secondary Lightning impulse withstand voltage: Withstands up to 60 kV .Below 5 pC Fire hazards . safe against vibrations and earthquakes .Withstands thermal and dynamic short circuit effects Specifications .Load losses and impedance voltage test Type tests .Temperature Rise: 100/100°C Vacuum Cast Coil Transformers: AL/AL Windings.Conductor protected from corrosion .Standard tests .Insulation resistance Humid or heavily polluted environments .Lightning impulse test . 30 .Measurement of noise level .Use of epoxy resins – not hygroscopic .Non toxic materials used .Partial discharge test .Vacuum Cast Coil Transformers ABB Power Technology Products .Mechanically stronger.Neither dioxins nor hydrohalogen compounds .Primary Voltage: Withstands up to 36 kV .Secondary Voltage: Withstands up to 6 kV .E2 class certified (tested for ambient 90% humidity and 50°C) . Please note that this table only shows a small sample of all productdesigns and ratings we supply.Temperature rise test .F1 class certified .Vector group .No-load loss and no-load current .Transformation ratio at all taps and polarity .C2 class certified (operation down to -25°C) .Self-Cooled Power Raiting: 50 kVA – 25 MVA .Applied voltage .Self-extinguishing .Induced voltage . ABB Power Technology Products 31 . This is why the liners Disney Wonder and Disney Magic use Vacuum Cast Coil transformers from ABB.Energy for leisure Few applications place higher demands on transformers than those aboard large cruise liners.Vacuum Cast Coil Transformers . Please note that this table only shows a small sample of all productdesigns and ratings we supply. Cenelec losses Highest voltage for equipment Rated power kVA 160 250 315 400 500 630 800 1000 1250 1600 2000 2500 36 kV Load loss at 75ºC W 2550 3520 4220 5020 6250 7040 8630 10240 12280 15130 18900 22500 AC 70 kV No-load loss at 100% Ur W 960 1280 1500 1650 1950 2200 2800 3100 3700 4200 5000 5800 LI 175 kV Short-circuit impedance % 6 6 6 6 6 6 6 7 7 8 8 8 Load loss at 120 ºC W 2900 4000 4800 5700 7100 8000 9700 11500 13800 17000 21000 25000 Sound power level dB 66 67 68 69 70 71 72 73 74 76 78 81 AC: Power frequency withstand voltage LI: Lightning impulse withstand voltage.Vacuum Cast Coil Transformers: AL/AL Windings.Vacuum Cast Coil Transformers ABB Power Technology Products . 32 . Vacuum Cast Coil Transformers: AL/AL Windings. Cenelec losses Highest voltage for equipment Rated power kVA 50 100 160 250 315 400 500 630 800 1000 1250 1600 2000 2500 24 kV Load loss at 75ºC W 1320 1850 2550 3340 4050 4840 6160 6860 8370 9790 12020 14240 17550 20700 AC 50 kV No-load loss at 100% Ur W 350 500 750 880 1150 1200 1500 1650 2100 2300 2900 3100 4200 5000 LI 125 kV Short-circuit impedance % 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Load loss at 120 ºC W 1500 2100 2900 3800 4600 5500 7000 7800 9400 11000 13500 16000 19500 23000 Sound power level dB 58 59 62 65 66 68 69 70 71 73 74 76 78 81 AC: Power frequency withstand voltage LI: Lightning impulse withstand voltage. Please note that this table only shows a small sample of all productdesigns and ratings we supply. ABB Power Technology Products 33 . a windy location in Denmark can become a gold mine.Vacuum Cast Coil Transformers .Good as gold With reliable and environmentally safe transformers from ABB. Please note that this table only shows a small sample of all productdesigns and ratings we supply. Vacuum Cast Coil Transformers: AL/AL Windings.Vacuum Cast Coil Transformers ABB Power Technology Products . 34 . Please note that this table only shows a small sample of all productdesigns and ratings we supply.Vacuum Cast Coil Transformers: AL/AL Windings. Cenelec losses Highest voltage for equipment 12 kV IP00 Rated power kVA 50 100 160 250 315 400 500 630 800 1000 1250 1600 2000 2500 A mm 1020 1100 1270 1280 1350 1440 1440 1550 1550 1620 1680 1840 1860 2050 B mm 800 800 800 850 850 850 850 900 900 900 1000 1000 1000 1250 H mm 1240 1240 1290 1440 1480 1520 1630 1650 1880 1900 2200 2250 2480 2500 B1 mm 300 300 300 375 375 375 375 375 375 375 490 490 490 615 B2 mm 450 450 475 475 495 495 525 525 575 575 610 610 635 635 E mm 520 520 520 670 670 670 670 670 670 670 820 820 820 1070 Ø mm 125 125 125 125 125 125 125 125 125 125 200 200 200 200 G mm 40 40 40 40 40 40 40 40 40 40 70 70 70 70 weight kg 520 730 860 1230 1310 1660 1570 2060 2170 2620 3100 4020 4630 5500 AC: Power frequency withstand voltage LI: Lightning impulse withstand voltage. Cenelec losses Highest voltage for equipment 24 kV IP00 Rated power kVA 50 100 160 250 315 400 500 630 800 1000 1250 1600 2000 2500 A mm 1020 1100 1270 1480 1550 1620 1620 1670 1680 1770 1800 1920 2000 2150 B mm 800 800 850 850 850 900 900 900 900 900 1000 1000 1000 1250 H mm 1300 1300 1350 1500 1550 1560 1700 1730 1950 1980 2270 2320 2550 2580 B1 mm 300 300 300 375 375 375 375 375 375 375 490 490 490 615 B2 mm 450 450 475 475 495 495 525 525 575 575 610 610 635 635 E mm 520 520 520 670 670 670 670 670 670 670 820 820 820 1070 Ø mm 125 125 125 125 125 125 125 125 125 125 200 200 200 200 G mm 40 40 40 40 40 40 40 40 40 40 70 70 70 70 weight kg 540 750 970 1320 1440 1760 1800 2260 2450 2910 3380 4240 4900 5900 AC: Power frequency withstand voltage LI: Lightning impulse withstand voltage. Vacuum Cast Coil Transformers: AL/AL Windings.Vacuum Cast Coil Transformers . Please note that this table only shows a small sample of all productdesigns and ratings we supply. ABB Power Technology Products 35 . Cenelec losses Highest voltage for equipment 36 kV IP00 Rated power kVA 160 250 315 400 500 630 800 1000 1250 1600 2000 2500 A mm 1450 1550 1600 1800 1800 1850 1920 1950 2000 2100 2200 2350 B mm 925 1000 1000 1000 1000 1000 1000 1050 1100 1150 1150 1300 H mm 1450 1600 1650 1700 1800 1850 2050 2100 2400 2450 2600 2650 B1 mm 300 375 375 375 375 375 375 375 490 490 490 615 B2 mm 625 625 625 625 675 675 725 725 760 760 785 785 E mm 520 670 670 670 670 670 670 670 820 820 820 1070 Ø mm 125 125 125 125 125 125 125 125 200 200 200 200 G mm 40 40 40 40 40 40 40 40 70 70 70 70 weight kg 1150 1420 1650 2100 2120 2550 3020 3250 3680 4480 5200 6200 AC: Power frequency withstand voltage LI: Lightning impulse withstand voltage. Thermo-resistor PT100 .Fans for forced cooling (up to 140% of AN rating). The Low Voltage and High Voltage windings are joined adhesively by way of bars to form a compact block winding. including control . rectifier and converter transformer. Standard features .Base equipped with bi-directional rollers or designed for skidding arrangement Options and accessories .Climatic class C2 .Reduced temperature rise on request 36 . RESIBLOC®. galvanized without painting . Epoxy resin moulding reinforced with fibre-glass rovings is a material of outstanding strength.Dial type thermometer (with capillary tube 2 m) .Tapping 2 x 2. The favourable impulse voltage distribution – resulting from the costly multilayering of the High Voltage winding – in conjunction with the outstanding strength of the coil makes RESIBLOC® resinencapsulated transformers short-circuit proof.Ratings: from 30 kVA to 30 MVA .Dimensions adaptable to specific requirements .PTC sensors. indoor and outdoor. Electronically controlled winding processes ensure uniform distribution of the glass rovings and precise tracking.Copper for LV windings . For more than a quarter of a century we have been using only epoxy resin and fibre-glass to encapsulate the wire layers.Environmental class E2 .LV Winding: Aluminum .Linear distribution of lightning impulse voltage .Temperature device .Secondary Voltages: up to 36 kV .Fire class F1 . multiwinding transformers .Primary Voltages: up to 41. We also guarantee that no silicone is used at any time in RESIBLOC® coil manufacture.HV Winding: Copper .Enclosure IP20 to IP65.5 kV .Special designs as traction.RESIBLOC® Resin-encapsulated Transformers ABB Power Technology Products . (1 set=4 pieces) .Anti-vibration pads.Earthing bolts (1 set=3 pieces) .5% . Furthermore we manufacture RESIBLOC® transformers without the addition of extenders or plasticizers.Built-in cooling channels to dissipate heat .RESIBLOC® Resin-encapsulated Transformers (≤ 30 MVA ) Construction features Description The ABB resin-encapsulated dry-type transformer.Environmentally friendly .BIL: According to standards . This is a further key point for those operators who demand absolutely silicone free manufacture from their transformer suppliers.Loss optimised design . offers specific advantages. The fibre-glass reinforcement of the resinencapsulated RESIBLOC® windings is so robust that we have no hesitation in guaranteeing the crack resistance of the High Voltage coil for the entire life of the transformer.Step-lap mitred core . with relay . Turns glued to each other with prepreg (LV winding) .Diagonally and radially fibreglass braced (HV-winding) .Every unit guaranteed to be self-extinguishing.Severe hot/cold dip tests .Tested with twice rated current at -40°C (standard test requirement only -25°C) .No horizontal ducts .Coil structure will withstand radial forces in short circuit conditions Moisture and pollution proof .Surface structure non-adhesive to dust ABB Power Technology Products 37 .High resistance to chemical pollution .Only non-toxic materials . Acceleration tested to 12.Vibration tested for installation in seismic areas.Approx. Fire class 1 certified Short circuit proof .High resistance to extremely low ambient temperatures .Physical and mechanical properties of coil components optimised .Minimum dust settles .Vertical cooling channels with chimney effect .HV and LV windings form a singular coil .High mechanical stability of coil structure .Small upper coil surface .No halogens.Severe thermo-shock tested .Performance stability under extreme load conditions . nor sulphur (fluorine/chlorine/bromine) .100% humidity and condensation proof .Repeated thermal shock with hot air 120°C and cold air -10°C (over 10 times) Fire proof .Safe to store and transport at -60°C (stan dard test requirement only -25°C) .Certified test results .All components tested for non-toxicity .Strong presence in off-shore applications .Max 5% calorific energy of comparable oil type unit .5 g .RESIBLOC® Resin-encapsulated Transformers .Not a single crack registered to date Minimal dust accumulation . 80% fibreglass in winding insulation .Long-term molecular stability due to absence of flexibilisers Crack proof . RESIBLOC® Resin-encapsulated Transformer Standard transformers Rated power kVA 100 160 250 315 400 500 630 250 315 400 500 630 800 1000 1250 1600 2000 2500 12 kV Load loss at 75ºC W 1700 2300 3000 3650 4300 5500 6400 3400 4100 5000 5700 6600 7700 8800 10500 12700 15500 19000 Load loss at 120 ºC W 2000 2700 3500 4200 4900 6300 7300 3900 4700 5730 6530 7600 8820 10000 12000 14000 18000 21000 No-load loss at 100% Ur W 440 610 820 950 1150 1300 1500 690 820 1000 1200 1370 1700 2000 2400 2800 3500 4300 Short-circuit impedance % 4 4 4 4 4 4 4 6 6 6 6 6 6 6 6 6 6 6 Sound power level dB 59 62 65 67 68 69 70 65 67 68 69 70 72 73 75 76 78 81 RESIBLOC® Resin-encapsulated Transformer Standard transformers Rated power kVA 100 160 250 400 630 100 160 250 315 400 500 630 800 1000 1250 1500 2000 2500 24 kV Load loss at 75ºC W 1550 2150 3000 4250 6000 1750 2500 3300 4000 4800 6000 6900 8100 9600 11500 14000 19000 20000 Load loss at 120 ºC W 1750 2500 3450 4900 6900 2050 2900 3800 4580 5500 6870 7800 9280 11000 13100 16000 19100 23000 No-load loss at 100% Ur W 600 870 1100 1450 2000 460 650 880 1050 1200 1400 1650 1900 2300 2700 3100 4000 5000 Short-circuit impedance % 4 4 4 4 4 6 6 6 6 6 6 6 6 6 6 6 6 6 Sound power level dB 59 67 65 68 70 59 62 65 67 68 69 70 72 73 75 76 78 81 AC: Power frequency withstand voltage LI: Lightning impulse withstand voltage. Please note that this table only shows a small sample of all productdesigns and ratings we supply. 38 .RESIBLOC® Resin-encapsulated Transformers ABB Power Technology Products . ABB Power Technology Products 39 .RESIBLOC® Resin-encapsulated Transformer Reduced no-load loss transforming Rated power kVA 100 160 250 315 400 500 630 250 315 400 500 630 800 1000 1250 1600 2000 2500 12 kV Load loss at 75ºC W 1700 2300 3000 3650 4300 5500 6400 3400 4100 5000 5700 6600 7700 8800 10500 12700 15500 19000 Load loss at 120 ºC W 2000 2700 3500 4200 4900 6300 7300 3900 4700 5730 6530 7600 8820 10000 12000 14000 18000 21000 No-load loss at 100% Ur W 320 440 600 730 880 1000 1150 540 640 780 940 1100 1330 1500 1880 2100 2750 3000 Short-circuit impedance % 4 4 4 4 4 4 4 6 6 6 6 6 6 6 6 6 6 6 Sound power level dB 51 54 57 59 60 61 62 57 59 60 61 62 64 65 67 68 70 71 RESIBLOC® Resin-encapsulated Transformer Reduced no-load loss transforming Rated power kVA 100 160 250 400 630 100 160 250 315 400 500 630 800 1000 1250 1600 2000 2500 24 kV Load loss at 75ºC W 1550 2150 3000 4250 6000 1750 2500 3300 4000 4800 6000 6900 8100 9600 11500 14000 16700 20000 Load loss at 120 ºC W 1750 2500 3450 4900 6900 2050 2900 3800 4580 5500 6870 7800 9280 11000 13100 16000 19100 23000 No-load loss at 100% Ur W 400 580 800 1100 1600 340 480 650 820 940 1100 1250 1460 1800 2080 2400 3100 3600 Short-circuit impedance % 4 4 4 4 4 6 6 6 6 6 6 6 6 6 6 6 6 6 Sound power level dB 51 54 57 60 62 51 54 65 59 60 61 62 64 65 67 68 70 71 AC: Power frequency withstand voltage LI: Lightning impulse withstand voltage. Please note that this table only shows a small sample of all productdesigns and ratings we supply.RESIBLOC® Resin-encapsulated Transformers . . ensuring that there is a continuous flow of gas and oil.Offshore of course About 200 RESIBLOC® transformers are installed on offshore platforms. Among our supplies in 1999 was another 15 MVA unit for Statoil’s Veslefrik field. . These should be manufactured competitively. Due to our long experience. Customers also expect accurate information and expert advice. But sometimes situations arise in which even the widest range of transformers currently available cannot meet the customer´s needs.Special Application Transformers Customers demand a wide range of excellent products. So it is little wonder that ABB has the most advanced transformers in operation around the world – from the very smallest to the largest and most sophisticated custom built units. oil-filled or dry. In those cases we design and build customised transformers to fulfil the customer´s requirements in every respect. our deep and wide engineering skills and our close co-operation with our customers we can find a practical solution to every problem. pole-mounted units through all standard units to meet all power requirements. ABB supplies a complete range of distribution transformers from single phase. Transformers for Special Applications Product Pad Mounted Transformers Transformers for Variable Speed Drives Reactors Boosterformers™ 42 .Special Application Transformers ABB Power Technology Products . Three-point terminal compartment laching 16. This proven design offers reliability.Pressure vacuum gauge . Completely factory assembled.2-FCBN on units with voltage above 601 V 7. Tank rated 8 psig for silicone filled units 10. screws or fasteners.Pad Mounted Transformers . thus providing a safe.Pad Mounted Transformers Construction features Description ABB padmounted transformers feature a tamper resistant construction with no externally accessible bolts. Base designed for rolling the unit in accordance with ANSI-IEC-DIN segment centre lines Options and accessories . HV/LV compartment barrier bolted in place 15. Special core and coil design 4. durability and reduced dimensions. Nearly 40 years of service and scrupulous testing confirm the consistency of the design.Special noise levels .Dead front primary entrance .5% 2-FCAN . Tamper resistant 2. Liquid preservation system with sealed tank 8. self-contained unit which cannot be accessed by unauthorised personnel. Tank rated 5 psig for oil-filled units 9. the units are shipped in one piece. Two copper-faced steel ground pads on tank 13.Special paint finishes ABB Power Technology Products 43 .Special ambient conditions .Copper windings .Dial-type thermometer . These units feature a rectangular core and coil design which is a distinguishing characteristic of ABB’s oil type transformers. Standard features 1. Lifting lugs for moving complete units 11. Tap changer for deactivated operation 6. or universal bushing wells for dead front b) Provision for distribution-class LAs c) Space for stress cones d) Interlocked door which can be opened only after opening LV compartment door 17. Four full capacity taps on winding rated 2. Weather-resistant cabinet bolted to the front of the transformer 14. Different paint finishes available 19.Non-standard HV taps .Basic impulse level adjustable on request . Copper or aluminium windings 3.Liquid level valve . hinges. LV compartment located on right side: a) Compartment door with provision for pad-lock b) Ground pad c) Provision for dial-type thermometer d) Provision for vacuum-pressure gauge e) Pressure relief valve f) Liquid level gauge g) Diagrammatic stainless steel rating plate 18.Special impedance . HV compartment located on left side of unit: a) Live front-cast resin bushings. Pressure relief valve 12. 65°C average temperature rise 5.Electrostatic shields .Special altitudes .Radiator valves .Sudden Pressure surge relay .CTs and PTs .55°C average winding temperature rise . Unsightly fences or other forms of protective devices are not necessary. six step inverters .diode and thyristor rectifiers q Output transformers Transformers for voltage step-up from converter to motor (see opposite). silicone or MIDEL fluid. EMC A specifically designed shield between transformer windings reduces transferred radio interference from the drive to the network. 30 MVA (primary power).PWM inverters . but not least. or as dry type transformers. Input transformers Why add an input transformer? Voltage adaptation Converter drives are normally fed by medium voltage networks from 6 kV up to 36 kV. The converter supply voltage usually ranges from 400 V up to 4 kV. 12. reduced harmonic distortion and last. q Transformers for converter starting applications Introduction With the increasing use and complexity of variable speed drives for different applications.Transformers for Variable Speed Drives ABB Power Technology Products . Galvanic isolation The input transformer isolates the converter from the feeding network and reduces short circuit currents to the converter. ABB offers converter transformers for your every need: Transformers are manufactured as oil-filled. selecting the correct converter transformer has become of vital importance. The transformers have been developed in close co-operation with converter manufacturers and with the aim of achieving the highest possible reliability and efficiency.cascade drives . energy saving. .g. 44 . extended equipment life. e. A symmetrical impedance and the capacity to withstand short circuiting are essential. Choosing the correct converter transformers for different converters and drive systems means reduced downtime. The earthed shield also protects the drive from transient over-voltages coming from the feeding network.cycloconverters (see opposite) .or 24-pulse supply for different converters. ABB offers you a wide range of converter transformers.Transformers for Variable Speed Drives q Input transformers for supply of drive systems 6-.load commutated inverters . The input transformer adapts the medium network voltage to the converter supply voltage. either mineral. They can be manufactured with an output of up to approx. rolling mill drives and similar equipment where only HV motor applications are available.Wind tunnel drives etc. or where low voltage cabling would not be feasible due to losses and voltage drop .Tappings are required to match the drive to different motor voltages or different cable lengths Output transformers are produced in oil type and dry type configurations up to 6 MVA ratings for various types of converter and output voltages up to 15 kV. which is also commonly used. The main parts of a cycloconverter drive are supply transformers. Typical applications for output transformers are when: .Cost of a high voltage converter is too high compared with a low voltage converter and an output transformer (low end rating of the converters) .Transformers for Variable Speed Drives . (Thus the name “converter step-up transformer”.Harmonics reduction Network regulations require reduction of harmonic distortion. Normally the voltage is raised from the Low Voltage converter to feed an HV motor. The following types of transformers are used: . Transformers for cycloconverter supply Cycloconverters are used for high power. icebreakers.Ship propulsion (see below) . They are designed to particular specifications to meet specific space problems (e.Mine hoist drives .The motor does not have a standard voltage converter (retrofit or by-pass application required) . The output step down transformers in the latest applications are submersible i.e.) A standard transformer cannot be used due to variation in frequency. A special step-up transformer has therefore been developed for this application in co-operation with converter manufacturers.4 winding transformers Output transformers for converters Converters are available for only a limited range of standard motor voltages. Nowadays it is also applied to cargo ships.3 winding transformers .Rolling mill drives . low speed synchronous motor drives such as: . the highest being 4 kV. the harmonic distortion and the DC component existing during transients in the output voltage of the frequency converter. they are placed on the seabed close to the motor. ferryboats etc.e. These transformers adapt the generated voltage to the voltage of the static converters which control the motors.Distance from the converter to the drive is long and a high voltage motor is used to reduce cabling costs. Typical applications Most typical applications are for submersible oil pump drives.2 winding transformers . ABB Power Technology Products 45 . Output transformers can also be applied to reduce the voltage at the end of a long transmission system to be more appropriate for a motor.g. high speed circuit breakers and the synchronous motor. Transformers are individually designed and manufactured according to system requirements. the cycloconverter. due to the installation and manoeuvring flexibility of motor groups and for space rationalisation as well as for the improvement in the system’s global performance. Different transformer connections are used to achieve multi-pulse systems with substantial harmonic reduction. A specially designed transformer can be used to transform the converter output voltage to match any motor rated voltage. Ship propulsion systems Electric propulsion for marine applications was initially used on holiday cruises for reasons of comfort (i. The transformer impedance acts as a commutating reactor and thus reduces harmonics. lower vibrations compared to mechanical propulsion). height limitations) and the presence of high harmonic currents as well as mechanical vibrations coming from the ship’s structure. 19400 kVA. Converter transformer. 13. water cooled RESIBLOC® transformer for shippropulsion.6-2. three-windings supply of LCI-drives.Transformers for Variable Speed Drives ABB Power Technology Products .Converter transformer. Ship propulsion transformer 6. Converter transformer. 4-windings.2 MVA.6 kVA – 6.1 kVA-AFWF. Converter transformer. 46 . Converter transformer. Converter transformer. Earthing-transformer (neutral coupler) arc-suppression .Cycloconverter drives . Saturable gapped core reactors . one to each generator. Fields of application .the reactor also works as a short circuit limiting reactor The commutation reactors are individually designed and manufactured according to system requirements. Commutation reactors Direct cycloconverters without supply transformers (e.Shunts . In this way the effect on harmonics does not depend on the operation. The duplex reactors are individually designed and manufactured according to system requirements. Single-phase and/or three-phase reactors are characterised by a wide range of solutions found in several high voltage and medium voltage installations for both oil and dry purposes. Therefore no standard types are listed. Duplex reactors Duplex reactors are special commutation reactors used in propulsion drives to achieve distortion free voltage in the auxiliary circuits. Two basic designs are used: 1.Tuning (filter) . propulsion and other drives where space and weight limitations are important) are usually fitted with commutation reactors. Reactors for cycloconverter drives Zero sequence reactors Zero sequence reactors are used to limit zero sequence current on motors with galvanically separated windings. Construction features Introduction Sıngle-phase and/or three-phase reactors are characterised by a wide range of solutions found in several High Voltage and/or Medium Voltage installations for both oil-type and dry purposes. The commutation reactors are normally dry-type but can also be manufactured as oil immersed.Damping . The most efficient harmonic reduction is achieved when the duplex reactors are connected to the generators.g.Reactors Duplex reactor for ship-propulsion. The reactors reduce the commutation currents and notches in the system voltage.Current-limiting .Reactors .Neutral-earthing current-limiting .no short circuit current limitation is needed 2.Smoothing ABB Power Technology Products 47 . Non-saturable type reactors . The reactors are individually designed and manufactured according to system requirements. Reactor for reduction of harmonic currents and trancient over – currents in DC Systems. Coreless. 24 MVA/10 s – Single Phase – 76 kV/ 8 kV-60 H2. 48 .Submarine converter transformer to be used to supply power and oil pumps. air-insulated.Reactors ABB Power Technology Products . Highly line are magnetic characteristics and withstand of over-voltages caused by lighting and switching. Can be placed at a depth of 2000 meters below the sea level. smoothing reactor to comply with transformer in railway applications. Earthing transformer for limitation of short-circuit current to earthfault. Extremely robust design (both electrical and mechanical). Boosterformers™ Cable Boosterformer™ for electric railway system.Boosterformers™ . ABB Power Technology Products 49 . Michael D. . Jean Louis Batt.Production: Cross Advertising. Bryan/Stock International Magazine Service. Greatshots © 2000 All Rights Reserved. January 2001 Printing: Tryckproduktion. Sweden Pictures: ABB. Wilhelm Schmidt/Pressens Bild. Sweden. Bud Freund. Ron Stroud. Jörgen Ulvsgärd. National Geographic. 8050 Zürich Switzerland Tel: +41 1 317 7111 www.Business Area Distribution Transformers P. . Box 8131 CH .abb.O.com Cross Advertising.
Report "ABB Oil Distribution Transformer Catalogue"
×
Please fill this form, we will try to respond as soon as possible.
Your name
Email
Reason
-Select Reason-
Pornographic
Defamatory
Illegal/Unlawful
Spam
Other Terms Of Service Violation
File a copyright complaint
Description
Copyright © 2024 DOKUMEN.SITE Inc.