86033501

March 30, 2018 | Author: ingemecsanfer | Category: Installation (Computer Programs), Computer Program, Technology, Computing, Computer Engineering


Comments



Description

Service NewsNo. 110031 Milking 2011-03-03 DeLaval cleaning unit C200 and C200 Combi New software version 1.60 A new software for DeLaval cleaning unit C200 and C200 Combi has been released. From April 2011 (production code ZD) all delivered units will have the new software installed. For previous units a software update is available. Updating instructions for the software are included in this Service News. Note! If updating from software version older than 1.51, the CPU-board 94776930 needs to be installed prior to the update. Corrections from previous version 1.51 n Display of pre-rinse start temperature is reintroduced. n The number of pre-rinse for tank cleaning C200 Combi was missing in previous version 1.51 (always 2 pre-rinses). This can now be programmed by parameter P365. n Parameters P47 and P48 is now functioning properly. Settings made in these parameters didn't correspond to the selected function. The parameters was accidentally switched. n Cleaning program 13 phase 5 was incorrectly defined as rinse. Now corrected to be as circulation with disinfectant. n Cleaning program 14, phase 5 was incorrectly defined as rinse. Now removed from the software. n Simplified calibration routine for temperature sensors, parameter P82 and P83. The temperature correction can now be set directly into parameters P82 and P83. To change displayed temperature, press the increase or decrease buttons until correct temperature is displayed and press the store button. © DeLaval 2011. 2011-03-03, Version 1 1 (6) 86033501 n Dosage of pre-rinse additive. Enable to start milking from for example the parlour via a remote start button. 2011-03-03. This happened when 2 pumps was installed P53 = 2 but a program which requires 3 pumps was selected. opposite to alkaline dominant cleaning. but not store values below the minimum limit of 0. n Remote start of milking. n Restart issue when selecting cleaning programs with 3 different types of detergents. n Air purge control from the cleaning unit.60. Sometimes when starting up the unit it was impossible to set the clock and the time didn't advance. This is corrected in version 1. Some outputs can be reconfigured according to pre-defined functions. When updating from version 1. Enable to start circulation cleaning during low cost energy period. n Acid dominant cleaning. The issue is now corrected by having no disinfectant dispensed if the required pump is not installed in the software P53 = 3. n Clear or restore the alarm history. n Configuration of outputs. This is now corrected by ignoring all values below 0. © DeLaval 2011.60 n Low energy timer start.5 seconds. New functions in version 1.51.n The clock loose track of time after more than 3 days of power off.51 it is possible to edit. n Parameter P23 External air injection on time. the display will show incorrect time and has to be reset. n ALCOM setup for Herd Navigator installation.5 seconds. In version 1. Version 1 2 (6) 86033501 . Dosage volumes to be set in parameter P6. Remote start of milking P47 Enable remote start of milking by an external start button 0 = Off Air purge control P73 Enable emptying the milk delivery line by an air purge valve. Time to let the valve stay open during air 1 . Acid dominant cleaning P72 Enable acid dominant cleaning. Version 1 0 = Disable » Continue next page 3 (6) 86033501 . 1 = System connected 2 = Stand alone P69 Herd navigator installed. After ending milking session the milking LED-indicator starts to flash. 2011-03-03.. parameter P58 must be enabled.1 = On sible from the milking pit. The milk pumps starts emptying the receiver and when finished the air purge valve starts to sweep the remaining milk in the delivery line into the milk bulk tank. P40 Numbers of acid cleaning before alkaline cleaning 1 . 0 = No To access parameter P69. It is possible to set clean.40 Dosage of prerinse additive P71 Enable dosage of pre-rinse additive at cleaning programs 0 = Off 1 to 8. 0 = Off 1 = On P38 Air purge time.0 = Off ing programs that will require numbers of acid cleaning before 1 = On an alkaline cleaning.0 = Off igator and C200. Connect the switch to terminal X3:2 and 3 and set parameter P47 to 1.60 seconds purge. 11. Configuration of outputs P400 Enable advanced I/O setting © DeLaval 2011. The air is taken via the cleaning line and C200 air injection valve (open during the complete milking). 14 and 15. Clear or restore alarm history In alarm view. 1 = On The alkaline dosage pump are divert to dosage pre-rinse additive at first or second pre-rinse (depending on P52 settings). Herd navigator P58 Enable ALCOM-bus communication between Herd Nav. the alarm history can be cleared by holding 0 = Cleared down the C button until digit 0 is displayed. Install a suitable push button switch at a location easy acces.New parameter numbers Function Description Option Low energy timer start P68 Enable to timer start circulation cleaning during low cost 0 = Off energy period. Alarm history can also be restored by holding down the C button until digit 1 is 1 = Restored displayed. 1 = On P37 Set selectable start time to utilize low cost energy period 00:00 .23:59 at cleaning phase II. 1 = Yes Herd navigator requires clean air to obtain transport of milk samples during milking. To activate a remote signal 1011 lamp when active alarm Remote alarm flashing signal.Function Description Option 1 = Enable P403 Configure output 3 (selectable function. A continuous Output signal 1003 during cleaning Tank cleaning active. see separate list below) 1 . see separate list below) P405 Configure output 5 (selectable function. © DeLaval 2011. see separate list below) P410 Configure output 10 (selectable function. Version 1 4 (6) 86033501 . see separate list below) Function Corresponding number Milking active. A continuous Output signal during milking 1002 Plant cleaning active. Flashing frequency 1013 2 Hz. Flashing frequency 1012 1 Hz. Remote alarm flashing signal.9999 P404 Configure output 4 (selectable function. see separate list below) P408 Configure output 8 (selectable function. 2011-03-03. A continuous Output signal 1004 Remote alarm signal. Follow the instructions on the screen. Dealers get the installation program through CD or downloading from the Dealer web support.2 or later is not installed on your computer. 1. the C200 software version 1. Download the program using the following link http://my.lom must be deleted prior to the installation.60. Switch off the power supply to the C200 and open the lid. Connect a serial cable between a serial port on the computer and the C200 CPUboard. Start the program Configuration Tool (for standalone units). which will be available for download spring 2011. 5. Otherwise continue from Ä step 4 on page 5.3.Installation The C200 is updated using the computer program Configuration Tool. Save the file under C:\Program Files\DeLaval\ConfigTool\C200\ Note! The existing file C200_89560150_1. When installed. Version 1 5 (6) 2.delaval.B. use a USB-to-serial (RS-232) converter.local/ProductsSolutions/ Solutions/Documents/Hygiene%20and %20Cleaning/Cleaning%20Units/ C200_89560150_1. If Configuration Tool 3. 002.8 m) 90624480.aspx. connected between the computer and the C200 CPU-board. The C200 software version will be included in Configuration Tool 3. © DeLaval 2011. Note! For computer with only USB-ports. 4. The computer program installs the new C200 software via a serial cable.3.60.msi. 86033501 . 7. open the folder and double click on Setup. Before the release of Configuration Tool 3.delaval.60 can be downloaded via http://my. 6. DeLaval recommends USB-to-serial converter 91595301 and extension serial cable (1. 3. Extract the downloaded zip-file to a folder you can find.lom. the program Configuration Tool can be started via "Start è All programs è DeLaval è Configuration Tool (for stand alone units)".exe or Setup. Switch on the power supply. follow these steps below. 2011-03-03.local/Tools/ToolPages/ Pages/SystemcontrollerDownload. 60 are set to default value. Select "Com port" and press "OK" 10.Supply Systems © DeLaval 2011. 203503 8. When the download of the application program is finished the display of the C200 shows “ready” (Load completed).2. Version 1 6 (6) 86033501 .Click on the icon Load software to serial port. The display of the C200 shows “boot” and shortly after “busy”. turn on the power. Click on the file to load "C200_89560150_1. 9. Note! If the installation of the software fails via Configuration Tool 3. re-download the software file from the intranet. All parameters new for version 1. Close the program and switch of the power to the C200. Note! Parameters programmed in previously installed version will stay unchanged with the update. 12. 2011-03-03. 11. 203506 203505 ð After a couple of seconds the load progress is visible both on the laptop and the display of the C200.60" and press "OK". Anders Westman Product Specialist . Start the application program download. disconnect the serial cable and put on the lid. 13. overwrite the previously downloaded software file and try again from Ä step 8 on page 6.
Copyright © 2024 DOKUMEN.SITE Inc.