Home
Login
Register
Search
Home
413 Topic v-3 (Run-Around Coil Systems, Regenerative Heat Ex Changers and Pinch Technology)
413 Topic v-3 (Run-Around Coil Systems, Regenerative Heat Ex Changers and Pinch Technology)
March 22, 2018 | Author: saadiis | Category:
Heat Exchanger
,
Heat
,
Heat Transfer
,
Hvac
,
Temperature
DOWNLOAD
Share
Report this link
Comments
Description
ISAT 413 - Module V: Industrial Systems Topic 3: Run-around Coil Systems, Regenerative Heat Exchangers, Pinch Technology Run-around Coil Systems: Definition of Run-Around Coil Systems Design Factors Examples 1 Run-around coil system of heat recovery A run-around coil heat recovery system is the name given to a linking of two recuperative heat exchangers by a third fluid which exchanges heat with each fluid in turn as shown diagrammatically below. 2 Run-around coil system A run-around coil would be used in cases where the two fluids which are required to exchange heat are too far apart to use a conventional direct recuperative heat exchanger. It is also desirable to use such an indirect system if there is a risk of cross-contamination between the two primary fluids (e.g. when a particularly corrosive fluid is involved, or when there is a risk of bacterial contamination as in a hospital). Advantage would be free choosing of working fluid. Disadvantage would be low effectiveness of the HX. Typical applications are recovery of energy from the air leaving a room or building to pre-heat the air entering; and recovery of energy from a corrosive gas for water heating. 3 Run-around coil heat recovery between fluids with the same thermal capacity m c C ! . m c H Q Q Q ! ! ! . t S1 t S 2 ! . t C1 tC 2 ! . t H 1 t H 2 . mc S . mc C . e.mc H i. . m c S ! . m c C ! . m c H and . t H 1 t S1 ! . t H 2 t S 2 . t S1 t C1 ! . 4 .t S 2 tC 2 . Run-around coil heat recovery between fluids with the same thermal capacity . m c ! . m c C H Assume the two heat exchangers are identical : t H 1 tC1 ! t S1 ! . UA H ! . UA C ! . t H 1 t S1 . t S1 tC1 2 t H 2 tC 2 and . H ! . C ! UA UA ! tS2 ! . t H 2 t S 2 . t S 2 tC 2 2 UA ! . . t t ! . . t t ! . H . t H 1 tC1 thus. UA H H 1 S1 UA C S1 C1 2 and since tC1 ! tC 2 . mc C UA ! . H . t H 1 tC 2 hence the heat recovery can be expressed as . UA H 2 . mc C 5 . (iii) the percentage energy saving by using the run-around coil. calculate: (i) the required mass flow rate of secondary fluid. Assuming that the mass flow rate of air is 2 kg/s.Example A run-around coil heat recovery system similar to that on slide 4 is used for a room in which the presence of bacteria rules out any possibility of air re-circulation or a direct recuperative heat exchanger. (ii) the temperature of the air leaving the run-around coil. the average outside air temperature during the annual period of use is 5oC. 6 .005 kJ/kg-K. Air enters the room at 24oC and leaves at 20oC.5 kJ/kg-K. that (UA)H = (UA)C = 4 kW/K. mean specific heat 1. and that the specific heat of the secondary fluid is 2. Example (i) . m c S ! . m c H ! . m c C ! 2 v 1.01 kW / K .005 ! 2. mc S ! 2 .01 ! 0.5 ! .804 kg / s ms ! cS 2 . H . t H 1 tC 2 ! 4. 04 kW (ii) Q .20 5 ! 15. 01 . H 4 2 2 2. 5o C .mc C 15.04 Q and t C1 ! tC 2 ! 5 ! 12. mc C 2.01 (iii) Without t he heat recovery the air must be heat from 5o C to 24o C hence the percentage energy saving is given by : . mc C . 5 5 v100% ! 39.4% % saving ! .12. mc C . 24 5 7 . Round-around coil heat recovery between fluids of different thermal capacity . mc C { . mc H 8 . Round-around coil heat recovery between fluids of different thermal capacity . mc H { . m c S { . mc C 9 . Round-around coil heat recovery between fluids of different thermal capacity . mc H { . m c S { . mc C 10 . Idealized run-around coil system . mc H . mc C _ H . C a . Required secondary fluid m S ! c S _m c H . C . m c C . H a . 11 . NTU method to analyze run-around coil heat recovery system) 12 .7 (use I.Example 5. Data: Mean specific heat of gases. (iv) the temperatures of the secondary fluid.Example 5.2 kJ/kg-K. 40 kW/K. 4. (UA) for the secondary fluid to water heat exchanger.2 kJ/kg-K. 3. 13 . 1. (ii) the effectiveness of the overall heat transfer. mean specific heat of secondary fluid.8 kJ/kg-K. (UA) for the gas to secondary fluid heat exchanger.7 A corrosive gas at a flow rate of 30 kg/s from a process at 300oC is to be used to heat 20 kg/s of water entering 10oC using a run-around oil as shown on slides 8 & 12. Calculate using the data given: (i) the mass flow rate of secondary fluid required. mean specific heat of water. (iii) the exit temperature of the water. 200 kW/K. 7 (i) The required mass low rate o secondary luid is given by .Example 5. mc H . mc C _UA H . UA C a . mS ! c S _m c H . C . m c C . H a . UA UA . 2 v .30 v1. 2 .20 v 4. 09 kg ! .40 200 ! 18. 2 v 40 .8_20 v 4. a 3. 30 v1.2 v 200 s 1 1 1 1 1 3 ! ! ! (ii) Since . overall . H S . S _ C 40 200 100 . since NT | .333 ! 0.926. overall ! 33. m c min 36 . mc min ! 36 ! 0.429 and R | . mc max 84 1 e NT v. 926v0. I ! NT v.571 ! ! 0.1 R 1 e 0.55 Hence HX effectiveness. 926v0. R 0.571 1 1 Re 1 0.429e 14 . 7 (iii) Since the definition of HX effectiveness is given by .Example 5. mc H . t H 1 t H 2 ! . m c C . tC1 tC 2 Q H or QC I! ! . mc min . t max t min . mc H . t H 1 tC 2 . m c H . t H 1 tC 2 . 30 v1.2 H v . 55 ! .300 t H 2 t ! 140.5o C I ! 0. 30 v1.2 H v . 300 10 H 2 . 2 C v .20 v 4. 4o C I ! 0.55 ! .tC1 10 t ! 78. 2 H v .30 v1. 300 10 C1 (iv) Since the heat transfer is given by @ station 1 : . H . t H 1 t S1 ! . C . t S1 t C1 . 40 H . 300 t S1 ! . 200 C . 3o C @ station 2 : .4 t S1 ! 115.t S1 78. H . t H 2 t S 2 ! . C . t S 2 t C 2 . 40 H . 140.5 t S 2 ! . 200 C . t S 2 10 t S 2 ! 31.8o C 15 . Temperature changes for Example 5.7 16 . Regenerative Heat Exchangers: Definition of Regenerative HX Design Factors Examples In a regenerative heat exchanger (sometimes called a capacitance heat exchanger) the hot and cold fluids pass alternately across a matrix of material. 17 . the matrix is heated up by the hot fluid then cooled down by the cold fluid so that the process is cyclic. Stationary Regenerative Heat Exchanger In (a) matrix B is hot and heats up the cold fluid while matrix A is heated by the hot fluid. in (b) the cold fluid is now heated by matrix A while the hot fluid re-heats matrix B. 18 . the valves are then switched over and the cycle commences again as in (a) . Rotary Regenerator or Thermal Wheel A matrix of material is mounted on a wheel which is rotated slowly through the hot and cold fluid streams as shown above. It is known as the thermal wheel. and Ljungstrom rotary regenerator after its Danish inventor. 19 . 93 ¿ ± « .Influence of Matrix Rotational Speed on Effectiveness ® ¾ ± ± ± ± 1 E ! E c ¯1 1. m c M » ± ± 9 ¬ . E c ! 1 e and .m c ¼ ± ° mi ½ À 1 e where. m c M ! Mc M ! X U. 1 U. . 1 . m c mi | . m c max Mc M 20 . Example 5. and a width of 0.8 (A rotary regenerator) A rotary regenerator is used to recover energy from a gas stream leaving a furnace at 300oC at a mass flow rate of 10 kg/s.5 m. The heat transfer coefficient for both fluid streams is 30 W/m2-K and the mean specific heats at constant pressure for the gas and air are 1.6 m2. Calculate: 21 . The wheel has a diameter 1.15 kJ/kg-K and 1. giving an approximate face area of 1. Heat is transferred to a mass flow rate of air of 10 kg/s entering at 10oC. the specific heat of matrix material is 0. the matrix has a surface area to volume ratio of 3000 m2/m3 and a mass of 150 kg. the rotational speed of the wheel is 10 rev/min.005 kJ/kg-K.8 kJ/kg-K.22 m. The overallheat trans er coe icien is given by ct h h 1 1 1 30 v 30 ! U ! C H ! ! 15 2 UA hH A hC A hH hC 30 30 m .8 (A rotary regenerator) (i) the effectiveness of the heat exchanger.Example 5.K ¨ A¸ 1 eat trans er area. A ! V v © ¹ ! . 22 v 3000 ! 1056m 2 ªV º . .6 v 0. 874 UA 15v1056 U! ! ! 1.576. ! .mc mi ! 10 v1.005 ! 0. 15 .mc max 10 v1. mc mi . 10v1.005v1000 10 k 1 e U. 636.576v0. .8 ! 20 Ec ! ! 0.126 c M ! v150v 0.1 1 e 1. m ! 1 U. 1.636¯1 ! 0.617 Where.576v0.126 60 K 1 e 1 0.05 ! 0.874e ¾ ® ± ± ® ¾ ± ± 1 1 k c mi ! 10. 93 ¿ K 1 ° 9.m E ! Ec ¯1 1.93 ¿ 1. .99 À ± « . mc M » ± ± 9¬ . mc ¼ ± ° mi ½ À 22 . From the de inition o heat exchanger e ectiveness E! ! 0.Example 5.8 (A rotary regenerator) (ii) the rate of heat recovery and the temperature of the air at exit.617 . mc mi . 617 v .t H 1 tC 2 10 ! 0. v1.005 v . 300 10 ! 1799 k Also. ! . m c . t t ! 10 v1.005 v . tC 1 ! 10 ! 189o C . 10.t 10 ! 1799 k mi C1 C2 C1 1799 exit temperature o air.05 23 . 1 min ! 20 v Given N ! 20 min min 60 sec .Example 5. rev .8 (A rotary regenerator) (iii) the air temperature at exit if the rotational speed of the wheel is increased to 20 rev/min. rev . 8 ! 40 .mc M ! 40 ! 3.98 kW 20 c M ! NMc M ! v 150 v 0. m . 93 ¿ 9.93 ¿ 1.m c min 10 v1.631 1.005 K 60 ¾ ± ± ¾ ± ± 1 1 ! 0.636¯1 ! c ¯1 ! 0. 98 À ± « .3. m c M » ± ± 9¬ . m c ¼ ± ° min ½ À . mc min . tC1 tC 2 ! 0.631 Q Therefore ! ! . m c min . t H 1 tC 2 . mc min . t H 1 tC 2 tC 1 ! 10 0.631v . 300 10 ! 193o C 24 . 8 (A rotary regenerator) (iv) the air temperature at exit if the rotational speed of the wheel is reduced to 5 rev/min. 1 min !5 v Given N ! 5 min min 60 sec . rev .Example 5. rev . 995 kW 5 c M ! NMc M ! v 150 v 0.8 ! 10 .m c M ! 10 ! 0. m . 636¯1 ! c ¯1 ! 0.93 ¿ 1.m c min 10 v1.005 K 60 ¾ ± ± ¾ ± ± 1 1 ! 0.93 ¿ ° 9.565 1. 995 À ± « .0. m c M » ± ± 9 ¬ . m c ¼ ± ° min ½ À . m c min . 565 Q Therefore ! ! .tC1 tC 2 ! 0. mc min . t H 1 tC 2 . m c min . t H 1 tC 2 tC 1 ! 10 0.565 v . 300 10 ! 173.8o C 25 . 26 . two burners are used in tandem so that continuous combustion can take place. while in (b) air is drawn through the matrix and supplied with gas to the burner where combustion takes place.Gas-Fired Regenerative Burners In (a) the hot gases are fed back through the burner and through a matrix to exhaust. Magnetic Heat Pump research at Oak Ridge National Laboratory 27 . 9 Double Accumulator Regenerative Heat Exchanger A double accumulator as shown above is to be installed to recover energy from the air leaving a building.. etc. 28 . The air leaves the building at 20oC at a rate of 2 kg/s and the mean outside air temperature for the heating season is 5oC. Calculate the rate of the recovery.Problem 5.. or Pinch Technology. Pinch Technology Concepts: Basic Concepts Design Factors Examples For many years the approach to a large network of heat exchangers was either by µrule of thumb¶ or a systematic mathematical examination of all possible configurations to try to achieve the best layout. Another approach to network design is given the name Process Integration. 29 . Additional heating and cooling are required to achieve the desire temperatures. 30 .Heat Exchanger Temperature Profiles The design of the heat exchanger is based on the minimum allowable temperature difference between the two streams being 20K. Simple Heat Recovery Scheme dditional/External heating : Qexternal . eating ! C C v . cooling ! C H v . .110 130 ! 2 v 20 ! 40 kW dditional/External cooling : Qexternal . 60 .30 ! 1v 30 ! 30 kW 31 . this point is called the Pinch point. 32 . The minimum temperature difference occurs where the two lines are nearest together .Temperature-Heat Load representation of Heat Recovery scheme The two lines representing the streams are positioned so as to show a region of overlap which represents the action of the HX in transferring 140 KW. 5 K/kW. which is 1/CC = 0. the amount of heat exchange between the two fluids is reduced and the external duties are increased. Note that the slope of the cold stream line is determined by the value of CC. 33 .Effect of µMoving¶ the Cold Stream The effect of increasing the Pinch temperature difference is twofold. Thus we can say that the lines can be moved horizontally within the limits of temperature and gradient until the nearest points are separated by the minimum allowable temperature difference. A similar argument applies to the external heating of the cold stream below the pinch: there must be no external heating of the cold stream below the Pinch. Also To achieve the target for the external cooling duty of the hot stream. that is the Pinch temperature difference.Effect of µMoving¶ the Hot Stream The same argument could be used for positioning the hot stream line. 34 . there must be no external cooling of the hot stream above the pinch. 35 . Stream Netwroks: Stream Network Concepts Design Factors Examples Considering the design of a system of heat recovery between two (or more) hot streams and two (or more) cold streams to illustrate some fine points of Pinch Technology. (oC) Rate of enthalpy increase (Cv(T) (kW) -280 -400 +405 +225 200 170 40 100 60 70 175 150 . (oC) Final temp. Stream Type Thermal number capacity rate.50 36 . For the purpose of definition. a hot stream is defined as one which requires cooling to reach its final temperature and a cold stream is one which requires heating to reach its final temperature. C (kW/K) 1 2 3 4 Hot Hot Cold Cold 2 4 3 4.5 Initial temp.1 (Pinch Technology) The heat flow capacities and temperatures of four streams are shown in the table below. The minimum allowable temperature difference between the streams is 20 K.Example 6. Composite Stream Heat Flow Capacities (Hot Stream Composite) 37 . Composite Stream Heat Flow Capacities (Cold Stream Composite) 38 . Hot and Cold Composite Curves 39 . 40 .Combined Hot and Cold Composite Curves From the graph the following information can be derived: hot stream temperature at the Pinch: 120oC cold stream temperature at the Pinch = 100oC target external heating load = ? kW target external cooling load = ? kW Cooling load will exceed the heating load by ? kW. alculati ns f External Heating ads 1 1 1 emperature 14 1 1 14 1 1 ling and target external heating load = 90 kW 4 target external cooling load = 140 kW 4 Heat ad 41 Cooling load will exceed the heating load by 50 kW. .
Report "413 Topic v-3 (Run-Around Coil Systems, Regenerative Heat Ex Changers and Pinch Technology)"
×
Please fill this form, we will try to respond as soon as possible.
Your name
Email
Reason
-Select Reason-
Pornographic
Defamatory
Illegal/Unlawful
Spam
Other Terms Of Service Violation
File a copyright complaint
Description
Copyright © 2024 DOKUMEN.SITE Inc.