3fe54967aaaatczza01_v1_7360 Isam Fx Olt r4.4, Ansi Product Information Guide

March 18, 2018 | Author: seamesai | Category: Network Packet, Ethernet, Network Switch, Command Line Interface, Communications Protocols


Comments



Description

ANSI PRODUCT INFORMATION GUIDEAlcatel-Lucent 7360 INTELLIGENT SERVICES ACCESS MANAGER FX | RELEASE 04.04 ANSI PRODUCT INFORMATION GUIDE 3FE 54967 AAAA TCZZA Edition 01 Alcatel-Lucent Proprietary This document contains proprietary information of Alcatel-Lucent and is not to be disclosed or used except in accordance with applicable agreements. Copyright 2012 © Alcatel-Lucent. All rights reserved. Alcatel-Lucent assumes no responsibility for the accuracy of the information presented, which is subject to change without notice. Alcatel, Lucent and the Alcatel-Lucent logo are registered trademarks of Alcatel-Lucent. All other trademarks are the property of their respective owners. Copyright 2012 Alcatel-Lucent. All rights reserved. Disclaimers Alcatel-Lucent products are intended for commercial uses. Without the appropriate network design engineering, they must not be sold, licensed or otherwise distributed for use in any hazardous environments requiring fail-safe performance, such as in the operation of nuclear facilities, aircraft navigation or communication systems, air traffic control, direct life-support machines, or weapons systems, in which the failure of products could lead directly to death, personal injury, or severe physical or environmental damage. The customer hereby agrees that the use, sale, license or other distribution of the products for any such application without the prior written consent of Alcatel-Lucent, shall be at the customer's sole risk. The customer hereby agrees to defend and hold Alcatel-Lucent harmless from any claims for loss, cost, damage, expense or liability that may arise out of or in connection with the use, sale, license or other distribution of the products in such applications. This document may contain information regarding the use and installation of non-Alcatel-Lucent products. Please note that this information is provided as a courtesy to assist you. While Alcatel-Lucent tries to ensure that this information accurately reflects information provided by the supplier, please refer to the materials provided with any non-Alcatel-Lucent product and contact the supplier for confirmation. Alcatel-Lucent assumes no responsibility or liability for incorrect or incomplete information provided about non-Alcatel-Lucent products. However, this does not constitute a representation or warranty. The warranties provided for Alcatel-Lucent products, if any, are set forth in contractual documentation entered into by Alcatel-Lucent and its customers. This document was originally written in English. If there is any conflict or inconsistency between the English version and any other version of a document, the English version shall prevail. When printed by Alcatel-Lucent, this document is printed on recycled paper. Preface This preface provides general information about the documentation set for the 7360 Intelligent Services Access Manager FX (7360 ISAM FX ) for ANSI. Scope This documentation set provides information about safety, features and functionality, ordering, hardware installation and maintenance, CLI and TL1 commands, and software installation procedures. Audience This documentation set is intended for planners, administrators, operators, and maintenance personnel involved in installing, upgrading, or maintaining the 7360 ISAM FX system. Prerequired knowledge The reader must be familiar with general telecommunications principles. Assistance and ordering phone numbers Alcatel-Lucent provides global technical support through regional call centers. Phone numbers for the regional call centers are available at the following URL: http://www.alcatel-lucent.com/myaccess For ordering information, contact your Alcatel-Lucent sales representative. Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 iii The release notes provide important information about the software load. for example. Warning — Warning indicates that the described activity or situation may. or will. or will. cause service interruption. iv May 2012 Alcatel-Lucent 7360 ISAM FX R04. Note — A note provides information that is. high voltage or electric shock hazards.Preface Safety information See the 7360 ISAM FX Safety Manual for safety information. or may be. Document conventions The following conventions are used in this documentation set. Caution — Caution indicates that the described activity or situation may. Acronyms See the glossary for the expansion of acronyms used in this documentation set. Danger — Danger indicates that the described activity or situation may result in serious personal injury or death.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide . of special interest. The following are examples of how special information is presented in this document. cause equipment damage or serious performance problems. Release notes See the release notes (such as the customer release notes or emergency fix release note) issued for software loads of the 7360 ISAM FX before you install or use the 7360 ISAM FX. Documents Table 1 lists the documents that make up the 7360 ISAM FX documentation set. Preface Table 1 7360 ISAM FX documentation set for ANSI Title Description General documentation Product Information Provides general system and ordering information for the 7360 ISAM FX System Description for FD 100/320Gbps NT and FX NT Provides conceptual information for the: • • Safety Manual 7302 ISAM and the 7330 ISAM FTTN equipped with the 100Gpbs or the 320Gbps NT 7360 ISAM FX equipped with an FX NT Provides general safety guidelines when handling. or operating the 7360 ISAM FX equipment Hardware documentation and unit data sheets FX Hardware Installation Guide Describes the hardware installation for the 7360 ISAM FX equipment UDS NFXS-D (FX-16) Describes the 7360 ISAM FX-16 slot shelf UDS NFXS-E (FX-8) Describes the 7360 ISAM FX-8 slot shelf UDS NFXS-F (FX-4) Describes the 7360 ISAM FX-4 slot shelf UDS NGFC-G Describes the 7360 ISAM FX-4 general facilities card UDS NGFC-H Describes the 7360 ISAM FX-8 general facilities card UDS FANT-F Describes the NT card UDS NELT-B Describes the GPON LT board (1) version B UDS NGLT-A Describes the GPON LT board (1) version A UDS dummy front panel FX NT Describes the dummy front panel (filler plate) for the NT card UDS dummy front panel FX LT Describes the dummy front panel (filler plate) for the LT card UDS AFAN-H Describes the fan unit for the 7360 ISAM FX-16 UDS AFAN-E Describes the fan unit for the 7360 ISAM FX-8 UDS AFAN-X Describes the fan unit for the 7360 ISAM FX-4 TL1 documentation TL1 Commands and Messages for FD 100/320Gbps NT and FX NT Describes the TL1 commands and messages for the: • • Operations and Maintenance Using TL1 for FD 100/320Gbps NT and FX NT 7302 ISAM and the 7330 ISAM FTTN equipped with the 100Gpbs or the 320Gbps NT 7360 ISAM FX equipped with an FX NT Provides task-oriented procedures using TL1 for operating and maintaining the: • • 7302 ISAM and the 7330 ISAM FTTN equipped with the 100Gpbs or the 320Gbps NT 7360 ISAM FX equipped with an FX NT CLI documentation CLI Commands for FD 100/320Gbps NT and FX NT Describes the CLI commands for the: • • 7302 ISAM and the 7330 ISAM FTTN equipped with the 100Gpbs or the 320Gbps NT 7360 ISAM FX equipped with an FX NT (1 of 2) Alcatel-Lucent 7360 ISAM FX R04. installing.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 v . “Board” is used in reference to ETSI terminology.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide . and “card” is used in reference to ANSI terminology. system management and OAM (Operations and Maintenance) IHub Interface Guide for FD 100/320Gbps NT and FX NT Describes the IHub system interfaces IHub QoS Guide for FD 100/320Gbps NT and FX NT Describes the IHub quality of service IHub Router Configuration and Protocols Guide for FD 100/320Gbps NT and FX NT Describes the IHub router configuration and router protocols IHub Services Guide for FD 100/320Gbps NT and FX NT Describes the IHub services MPLS Guide for FD 100/320Gbps NT and FX NT Describes the IHub MPLS services Software documentation Software Installation Guide Describes the software management of the 7302 ISAM. the 7330 ISAM FTTN and the 7360 ISAM FX (2 of 2) Note (1) vi The term “board” and “card” are both used in the 7360 ISAM FX documentation set. May 2012 Alcatel-Lucent 7360 ISAM FX R04.Preface Title Description Operations and Maintenance Using CLI for FD 100/320Gbps NT and FX NT Provides task-oriented procedures using CLI for operating and maintaining the: • • 7302 ISAM and the 7330 ISAM FTTN equipped with the 100Gpbs or the 320Gbps NT 7360 ISAM FX equipped with an FX NT IHub System Basics. Management and OAM Guide for FD 100/320Gbps NT and FX NT Describes the IHub system basics. the 7330 ISAM FTTN and the 7360 ISAM FX equipment Software Upgrade and Migration Application Procedures Provides instructions for using the automated tools for upgrading and migrating the software for the 7302 ISAM. ........................................................... iii Safety information..............................................................1 1..........2 1-1 2-1 Overview ...................................................... 1-17 NT redundancy support.................................. iii Prerequired knowledge ................................................ iv Document conventions ................................................................ 1-7 Network management...........7 1....................................... 2-2 Alcatel-Lucent 7360 ISAM FX R04............................................................................................5 1........................................................Contents Preface iii Scope ...................................................................................................................................................................................... iv Documents ..........................................04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 vii ......................................................................................................................3 1.....6 1......... 1-14 Equipment management ........................................................ 1-2 Feature descriptions....................... iii Audience ........................................................ 1-6 System architecture .................................................................................................................... iv Release notes ....1 2.............................................. iii Assistance and ordering phone numbers ................................................................................................................................................................................................... 1-16 Card capabilities and dimensioning............4 1..................................... 1-24 Shelves 2................................................... iv System and equipment overview 1— System overview 1................................. 1-23 CLEI codes.................... 2-2 7360 ISAM FX shelves..........................................................................2 1................................................8 2— Introduction .......... ...............................1 3.. 5-2 Rack considerations .................. 2-7 Dummy front panels ............................................................... 3-3 7360 ISAM FX-8 rack mounting configurations ..........................04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide ......................................................................4 6..................... 6-7 Fan units and fan filters .............. 5-8 Documentation ....................3 6.......................12 6— 6-1 Overview ................9 5................................. 6-10 Optical modules....................... 5-5 NT card considerations.................. 4-2 Characteristics............................................1 4..................................................9 6.7 5..........................................................................1 viii Overview ...................................5 4— Supported plug-in units......................................................................................................6 6.....................................................................2 3-1 4-1 Overview ....................6 5...................................................................................................................................................1 6....................................................................................7 6....... 5-1 A-1 Mnemonics overview.......................................... 6-8 NT card and dummy front panel ....................................................................................................11 5................................................ 5-7 Power considerations ...............10 5................. 5-4 LT card considerations ............................ 6-9 NTIO card and dummy front panel..........................................2 6.............................................................. 5-8 Software licensing information .......... 4-2 Planning and ordering 5— Planning the equipment 5................ 6-10 LT cards and dummy front panels .........................A-2 May 2012 Alcatel-Lucent 7360 ISAM FX R04............3 2.......................5 6......... 6-11 Cables ....... 6-3 Shelves ........................... 3-2 7360 ISAM FX-16 rack mounting configurations .................................................. 5-2 Network considerations ..............................................................................................2 5.................10 A............................................................................................................. 3-5 7360 ISAM FX-4 rack mounting configurations .....................4 5...........Contents 2.............................. 5-5 V-OLT and video coupler equipment considerations........................................................ 5-8 Ordering the equipment 6.............3 3................. 6-2 Racks and mounting parts ........................4 3— Rack mounting configurations 3.....................3 5.........5 5...... 6-13 Mnemonics A........................................................................................... 3-8 Optical modules 4.......................................8 5.......................................................................................................1 5................. 5-4 Shelf considerations ................................................ 5-8 Maintenance considerations........................... 3-2 Rack equipment ........... 6-6 GFCs..................................................................2 3.....................................................................................8 6........................... 5-5 Installation considerations .................. 2-8 Overview ........4 3........................................................ 04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 ix .Contents Glossary Index Alcatel-Lucent 7360 ISAM FX R04. ................................ 1-12 1-7 FANT-F in 7360 ISAM FX-8.............. 1-15 2-1 7360 ISAM FX-16 shelf ......................Contents List of figures Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure 1-1 Basic 7360 ISAM FX network topology .................................... 1-8 1-7 7360 ISAM FX system components .............................................................................................................. 1-6 1-2 Features for 7360 ISAM FX R4.............................. 1-17 1-11 Faceplate port applicability for SyncE ................................................................................. 1-5 1-5 Network connections ........................................................................................................................................................................................4....... 3-4 3-2 Horizontal rack mounting configurations for 7360 ISAM FX-8 in an EIA standard 19 in................................................................................................................................................................. 2-4 2-4 Shelf configuration of 7360 ISAM FX-16 .............................................................. 1-3 1-2 Cascading topology mode ..................... 2-7 2-8 Dummy front panel for NT card............................................... 2-4 2-3 7360 ISAM FX-4 shelf .................3............................ 1-6 1-6 7360 ISAM FX functional components ................. 2-3 2-2 7360 ISAM FX-8 shelf ................. 3-7 Figure 3-4 Horizontal rack mounting configurations for 7360 ISAM FX-4 in an EIA standard 19 in...............................02 ......... rack ...... rack................................................................................................ 3-9 Figure 3-5 Horizontal rack mounting configurations for 7360 ISAM FX-4 in a 23 in.......................3.........................................04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide .............. 3-10 List of tables Table Table Table Table Table Table Table Table Table Table Table Table Table Table x 1 7360 ISAM FX documentation set for ANSI..................01 .............................................................................................. 1-7 1-3 Features for 7360 ISAM FX R4.................................................................................................................................................................. rack.................................................................................................... 1-20 May 2012 Alcatel-Lucent 7360 ISAM FX R04......................................................................................................................................................................................................... v 1-1 Features for 7360 ISAM FX R4..... 1-11 1-6 FANT-F in 7360 ISAM FX-16.............. 2-5 2-5 Shelf configuration of 7360 ISAM FX-8.............. 2-9 2-9 Dummy front panel for optical LT card......................................... 1-18 1-13 Ethernet frame size for LT cards ....... 1-9 1-9 7360 ISAM FX network management ....................................................... 1-8 1-8 7360 ISAM FX forwarding architecture ................................................................................................... 3-6 Figure 3-3 Horizontal rack mounting configurations for 7360 ISAM FX-8 in a 23 in............................. 1-15 1-10 7360 ISAM FX management topology .................. 1-10 1-5 Mapped items in a 7360 ISAM FX system .......................................... 1-18 1-12 IWF capabilities............................ 1-13 1-9 Manager overview .................................................................................................................................................... 1-16 1-10 NT card dimensioning ............................................................................................. 2-6 2-7 Heat and fiber management baffle for 7360 ISAM FX-16 ............................................................... 1-4 1-3 Star topology mode .............................. 2-10 2-10 Universal dummy front panel for NTIO card ................................................................. 2-6 2-6 Shelf configuration of 7360 ISAM FX-4..................... 1-12 1-8 FANT-F in 7360 ISAM FX-4..... 2-11 3-1 Rack mounting configurations for 7360 ISAM FX-16 (3FE 66742 AB).................................... 1-4 1-4 Ring topology mode ............ rack ............................. 1-7 1-4 Supported LT cards ............................................................. ........ 6-9 6-10 Orderable NTIO dummy front panel .. 6-2 6-2 Rack mounting configurations ................................................ 6-4 6-6 Orderable 7360 ISAM FX shelves ............................................. 1-24 2-1 7360 ISAM FX shelves supported........ 3-5 3-4 Horizontal rack mounting configurations for 7360 ISAM FX-4.......................................... 5-4 5-3 Number of LT ports per LT card ............................. 5-5 5-4 Number of NT ports per NT card ....................................................................................... 1-23 1-17 NT Redundancy support-ready hardware modules ................................................................................................................................................................. 2-5 2-3 Mounting options/kits for 7360 ISAM FX shelves ......................................... 6-7 6-8 Orderable fan units and filters ......................................................Contents Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table 1-14 LT card dimensioning information ................................... 1-22 1-16 Total number of ports per LT card ............................... 3-8 4-1 Characteristics of approved optical modules ...... 3-2 3-2 Rack mounting configurations for 7360 ISAM FX-16........................... 2-2 2-2 Shelf configurations............ 4-2 5-1 Number of shelves per rack ........................................................... 2-7 2-4 Supported plug-in units in 7360 ISAM FX shelves.......................................................... 3-3 3-3 Horizontal rack mounting configurations for 7360 ISAM FX-8......................... 6-3 6-5 Rack mounting parts for 7360 ISAM FX-8 and 7360 ISAM FX-4 ........ 5-5 6-1 7360 ISAM FX equipment.............................................................................................. 2-8 3-1 7360 ISAM FX supported rack equipment.............................................................. 6-3 6-4 FEMA level rack mounting parts for 7360 ISAM FX-16 .......................................................................................................... 6-6 6-7 Orderable GFCs........................ 6-13 A-1 Equipment mnemonics ........................................................................................................................................ 1-21 1-15 GPON-specific dimensioning information ................................................................................................................... 6-3 6-3 Racks ........................................................... 6-10 6-12 Orderable optical modules......................................................................................................................... 6-10 6-11 Orderable LT cards and LT dummy front panels.. 6-11 6-13 Orderable CO external alarm cables ............................................................ 5-4 5-2 Ordering plug-in units and cables for the 7360 ISAM FX shelves .................................................................................................. 6-8 6-9 Orderable NT card and NT dummy front panel ...................................................................................................................................................A-2 Alcatel-Lucent 7360 ISAM FX R04.......04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 xi ................................... 1-24 1-18 CLEI codes..... Contents xii May 2012 Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide . System and equipment overview 1 — System overview 2 — Shelves 3 — Rack mounting configurations 4 — Optical modules Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 . May 2012 Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide . 4 Network management 1.5 Equipment management 1-14 1-16 1.7 NT redundancy support 1.6 Card capabilities and dimensioning 1.1 — System overview 1.8 CLEI codes Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 1-17 1-23 1-24 1-1 .1 Introduction 1-2 1.2 Feature descriptions 1-6 1.3 System architecture 1-7 1. 1 — System overview 1. 1-2 May 2012 Alcatel-Lucent 7360 ISAM FX R04. equipment management. feature descriptions. and CLEI code information. card capabilities. high-speed Internet access. Network topology The 7360 ISAM FX system is a frame-based multi-service access platform. Figure 1-1 shows the basic 7360 ISAM FX network topology. voice. NT redundancy support. offering high-density fiber connections for multimedia. network management.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide .1 Introduction This chapter provides general information about the 7360 ISAM FX system including network topology. system architecture. and business services. 1 — System overview Figure 1-1 Basic 7360 ISAM FX network topology IP edge router/ BRAS NSP IP backbone Ethernet Switch FE/GE/ 10GE Ethernet DS1/E1 ISAM NSP IP backbone EMAN Video FE/GE/ 10GE NSP IP backbone ISAM ISAM shelf Ethernet FE/GE/10GE Eth LT FE/GE/10GE DS1/E1 Video Ethernet ONT ONT OMCI GPON GPON LT NT EPON LT OAM EPON ISAM OLT 22417 Note 1 — Possible user interface types are not limited to the types shown in the Figure 1-1. an Ethernet link. Note 2 — A link is a term that refers to the physical layer of an interface of the 7360 ISAM FX. Subscriber side At the subscriber side. for example.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 1-3 . each 7360 ISAM FX shelf can terminate: • Ethernet user interfaces • PON interfaces Alcatel-Lucent 7360 ISAM FX R04. 04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide . see Figure 1-2 • star topology mode: multiple subtending ISAMs per ISAM. see Figure 1-4 Figure 1-2 Cascading topology mode Cascading up to three levels k*FE/GE/10GE k*FE/GE/10GE ISAM ISAM User interfaces ISAM EMAN User interfaces User interfaces 22420 Figure 1-3 Star topology mode k*FE/GE/10GE ISAM ISAM EMAN User interfaces User interfaces ISAM k*FE/GE/10GE User interfaces 22421 1-4 May 2012 Alcatel-Lucent 7360 ISAM FX R04.1 — System overview You can connect subtending DSLAMs to the FE/GE/10GE links at the subscriber side in: • cascading topology mode: a chain of one subtending ISAM per ISAM. see Figure 1-3 • ring topology mode: (except when there is a ring behind a Hub-ISAM). the frames enter the IP backbone of the NSP. These Ethernet switches forward the frames over the Ethernet-based aggregation access network until they reach the IP edge router or BRAS of the corresponding NSP. GE.1 — System overview Figure 1-4 Ring topology mode k*FE/GE/10GE ISAM User interfaces k*FE/GE/10GE ISAM ISAM EMAN User interfaces User interfaces ISAM k*FE/GE/10GE User interfaces 22422 Network side At the network side. Alcatel-Lucent 7360 ISAM FX R04. the 7360 ISAM FX terminates FE. At the IP edge router or BRAS.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 1-5 . Ethernet link aggregation is used. Ethernet links can be connected to one or more Ethernet switches. The 7360 ISAM FX can be connected directly to the IP edge router or BRAS. In case of more than one link. • Connect to a MPLS network. • Connect more than one FE/GE/10GE link (link aggregation). or 10GE links. The Ethernet aggregation network is reduced to one or more parallel Ethernet links. Figure 1-5 shows the 7360 ISAM FX system network connections. • Connect to one or more Ethernet switches. Following are possible configurations. • Connect directly to an IP edge router. 01 Feature ANSI hardware support Description Following is a list of ANSI-supported hardware for release 4.01: • • • • • • • • • • • • NFXS-D. GFC for the 16-slot shelf (preinstalled) NGFC-H. GPON LT card version A PDBP-C. 16-slot shelf NFXS-E.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide .01 features Table 1-1 describes the features for 7360 ISAM FX R4. BC variant NT card with a 480 Gbps switch NELT-B.3. 1-6 May 2012 Alcatel-Lucent 7360 ISAM FX R04. fan unit for 16-slot shelf AFAN-E. GFC for the 4-slot shelf AFAN-H.3. fan unit for 4-slot shelf Table 1-2 describes the features for 7360 ISAM FX R4. 8-slot shelf NFXS-F. 4-slot shelf FANT-F. GFC for the 8-slot shelf NGFC-G.1 — System overview Figure 1-5 Network connections IP edge router/ BRAS NSP IP backbone Ethernet Switch User interfaces m x FE/GE/10GE NSP IP backbone EMAN ISAM FE/GE m x FE/GE/10GE NSP IP backbone User interfaces NSP IP backbone ISAM FE/GE 22423 1.3. Table 1-1 Features for 7360 ISAM FX R4.3.01.02. GPON LT card version B NGLT-A.2 Feature descriptions This section provides a brief description of the features for the 7360 ISAM FX system.3. fan unit for 8-slot shelf AFAN-X. Release 4. Table 1-3 Features for 7360 ISAM FX R4. 8 port GPON LT card XG-PON1 OLT XFP N1 Ctemp XG-PON1 ONU SFP+ N2A Itemp 1.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 1-7 .4 Feature Description ANSI hardware suppport FGLT-A.1 — System overview Table 1-2 Features for 7360 ISAM FX R4. BD variant NT card with a 480 Gbps switch Table 1-3 describes the features for 7360 ISAM FX R4.4.3 System architecture This section describes the 7360 ISAM FX system architecture including the functional and physical components. 16 port GPON LT card NGLT-C. and IHub.02 Feature Description ANSI hardware support FANT-F. Functional components The 7360 ISAM FX is a multiplexer. Related information is provided in the customer documentation in anticipation of their subsequent availability. which can be equipped with the following main cards: • • • • NT card (optionally 1+1 redundant) NTIO card (optional) (not currently supported) LT cards implementing the user interfaces GPON LT cards Note — The XG-PON1 LT card is not supported in the current release. Figure 1-6 shows the 7360 ISAM FX functional components.3. Alcatel-Lucent 7360 ISAM FX R04. . LT-applique 22424 The 7360 ISAM FX management plane. Figure 1-7 shows the 7360 ISAM FX system components. • The IHub subsystem has enhanced L2 functionality (VPLS based) and L3 functionality (VPRN based) and consists of a 10 GE switch/router device. and IHub control SW. The system control consists of SW running on a general purpose processor. Figure 1-7 7360 ISAM FX system components LT NT iHub LT-Control iHub control Transport IWF Switch/Router System control Data plane Control plane 22425 NT cards The 7360 ISAM FX NT cards consist of an IHub subsystem and a system control subsystem.1 — System overview Figure 1-6 7360 ISAM FX functional components ISAM NT LT NTIO . 1-8 May 2012 Alcatel-Lucent 7360 ISAM FX R04.. and most of the data plane are provided on the NT cards and on the LT cards.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide . • The system control subsystem implements the management plane of the system (both the NT cards and the LT cards) and part of the control plane (subscriber management in particular). shared with the IHub control SW (on a separate processor core). control plane. • The transport subsystem terminates the physical layer of the user interfaces. all at the line rate of the transport medium. Figure 1-8 7360 ISAM FX forwarding architecture Network links Subtending links User links NT LT IHUB router EMAN EPS IHUB control 2-n IWF Transport LT control Ethernet GPON EPON CPE ONT ONT NTIO System control 22426 A 7360 ISAM FX shelf consists of the following card types: • NT cards • LT cards Alcatel-Lucent 7360 ISAM FX R04. • The IWF processes the packets in the fast path. or the ONTs.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 1-9 . such as Ethernet. including sophisticated filtering and traffic management. • The LT control subsystem provides the slow path control plane and internal operations and maintenance applications. XG-PON1 LT cards The XG-PON1 functionality of the 7360 ISAM FX provides higher speed data rates of 10G downstream and 2.5G updstream. GPON LT cards The GPON functionality of the 7360 ISAM FX extends the system boundaries up to 128 ONTs over fiber that can reach tens of kilometers from the GPON LT cards located in a 7360 ISAM FX shelf. and an LT control subsystem. a transport subsystem. The IWF is capable of handling frames at L2 (basically bridging) and L3 (basically IP forwarding).1 — System overview LT cards The 7360 ISAM FX LT cards provide an IWF. The transport subsystem varies with the type of access technology used. These GPON LT cards provide the physical interfaces from the 7360 ISAM FX shelf toward the CPE. Physical components Figure 1-8 shows the forwarding architecture of the 7360 ISAM FX system. Table 1-4 lists the supported LT cards with their physical interface types. LCMI interface (RJ-45 connector) ToD/1PPS interface (RJ-45 connector) 10 MHz GPS interface (SMA connector) 1 PPS interface (SMA connector) LT cards The LT cards in the shelf consist of an IWF. 100 Mb/s. The LT cards. Table 1-4 Supported LT cards LT card Physical interfaces Overlay Density NT interface IWF NELT-B Ethernet — 36 10 GE L3 (1) FGLT-A GPON — 16 40 GE L3 (1) (2) NGLT-A GPON — 8 10 GE L3 (1) (2) NGLT-C GPON — 8 20 GE L3 (1) (2) Notes (1) L3: IWF capability on Layer 2 and Layer 3. and the LT control. 4 x 10 GE SFP+ port: This port operates in 1 GE mode (with standard SFP optics) and in 10 GE mode (with SFP+ optics). density (that is. also known as LIMs. The FANT-F (480 Gbps) NT card is supported in 7360 ISAM FX equipment. This NT card with integrated IHub subsystem provides the following links on the front panel: • 1 x fixed 10/100/1000Base-T port. • • • • • This port operates in 10 Mb/s. see section 1. see Table 1-12. number of lines per card). These NT cards can act as an active/standby pair for all functions. (2) Not all L3 features are supported in these ports. the transport termination. depending on the card type. and IWF capability. use a different IWF between the user side and the Ethernet network side.6. 1-10 May 2012 Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide . For an overview of the IWF capabilities. or 1 GE mode.1 — System overview • NTIO card (not currently supported) • GFC card NT cards The shelf can accommodate two NT cards. dependant on the NT redundancy configuration. If the active NT fails. how this port can be configured: • • • • Alcatel-Lucent 7360 ISAM FX R04. visual indications for power availability.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 UP for uplinks/subtending/user links DOWN for internal LT links FIXED for fixed configuration (UP or DOWN) CONF for configurable configuration (UP or DOWN) 1-11 . and collection and cascading of external alarms. NTIO card The 7360 ISAM FX NTIO card plays the role of an applique to a single NT card. Port mapping The following tables list the port mapping for the 7360 ISAM FX system. Table 1-5 Mapped items in a 7360 ISAM FX system Item Description Physical port number Physical switch device port number Logical port number Port number as denoted in the SNMP management interface LT port number For internal LT ports. that is. the mapping between the logical port numbers as used in the system and the physical port numbers as visible on the equipment (front panel numbering). • Table 1-8 lists the port mapping for the FANT-F card in a 7360 ISAM FX-4 shelf. Note — These cards are only used on the 7360 ISAM FX-8 and the 7360 ISAM FX-4. The NTIO card can decouple NT equipment protection from up-link protection in case of a redundant NT pair. • Table 1-7 lists the port mapping for the FANT-F card in a 7360 ISAM FX-8 shelf. • Table 1-5 lists the mapped items in a 7360 ISAM FX system.1 — System overview GFC card The GFC provides connections for external power. how this port is identified at the front panel of the card Port state / configurability For NTIO ports. the index of the LT in the main shelf that corresponds to this port (for local LTs only) (index based) Front panel port number For external ports. or to both NT cards. circuit breakers for system protection. • Table 1-6 lists the port mapping for the FANT-F card in a 7360 ISAM FX-16 shelf. traffic on the NTIO external links will be switched automatically to and from the standby NT. 1 — System overview Table 1-6 FANT-F in 7360 ISAM FX-16 Physical port number Logical port number LT slot number (index based) Faceplate port number Interface 10 15 1 — — 12 16 2 — — 16 17 3 — — 18 18 4 — — 32 19 5 — — 34 20 6 — — 41 21 7 — — 43 22 8 — — 45 23 9 — — 37 24 10 — — 22 25 11 — — 8 26 12 — — 39 27 13 — — 28 28 14 — — 20 29 15 — — 17 30 16 — — 2 5 — 1 (NT-A) RJ-45 4 6 — X1 (NT-A) SFP+ 5 7 — X2 (NT-A) SFP+ 6 8 — X3 (NT-A) SFP+ 7 9 — X4 (NT-A) SFP+ 3 3 — IEEE1588 (NT-A) — — 10 — 1 (NT-B) RJ-45 — 11 — X1 (NT-B) SFP+ — 12 — X2 (NT-B) SFP+ — 13 — X3 (NT-B) SFP+ — 14 — X4 (NT-B) SFP+ — 4 — IEEE1588 (NT-B) — Table 1-7 FANT-F in 7360 ISAM FX-8 Physical port number Logical port number LT slot number (index based) Faceplate port number Interface 10 15 1 — — 12 16 2 — — (1 of 2) 1-12 May 2012 Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide . 04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 1-13 .1 — System overview Physical port number Logical port number LT slot number (index based) Faceplate port number Interface 16 17 3 — — 18 18 4 — — 32 19 5 — — 34 20 6 — — 41 21 7 — — 43 22 8 — — 2 5 — 1 (NT-A) RJ-45 4 6 — X1 (NT-A) SFP+ 5 7 — X2 (NT-A) SFP+ 6 8 — X3 (NT-A) SFP+ 7 9 — X4 (NT-A) SFP+ 3 3 — IEEE1588 (NT-A) — — 10 — 1 (NT-B) RJ-45 — 11 — X1 (NT-B) SFP+ — 12 — X2 (NT-B) SFP+ — 13 — X3 (NT-B) SFP+ — 14 — X4 (NT-B) SFP+ — 4 — IEEE1588 (NT-B) — (2 of 2) Table 1-8 FANT-F in 7360 ISAM FX-4 Physical port number Logical port number LT slot number (index based) Faceplate port number Interface 10 15 1 — — 12 16 2 — — 16 17 3 — — 18 18 4 — — 2 5 — 1 (NT-A) RJ-45 4 6 — X1 (NT-A) SFP+ 5 7 — X2 (NT-A) SFP+ 6 8 — X3 (NT-A) SFP+ 7 9 — X4 (NT-A) SFP+ 3 3 — IEEE1588 (NT-A) — — 10 — 1 (NT-B) RJ-45 — 11 — X1 (NT-B) SFP+ — 12 — X2 (NT-B) SFP+ (1 of 2) Alcatel-Lucent 7360 ISAM FX R04. subtending links. see Table 1-4. for uplink. as electrical FE or GE interfaces. • link interfaces that are physically located on the NT card. The connection speed depends on the LT capabilities.4 Network management This section provides network management information for the 7360 ISAM FX system.5 Gb/s or at 10 Gb/s to an LT local in the shelf (one IHub link per LT). or 10GE interfaces. A number of ports are used to make a connection at 1 Gb/s or at 2. or optical GE or 10 GE interfaces. or user links. which are not used for connecting LT cards (local or remote). These links serve network links. and the 10GE ports. for uplink. 1. Use of these ports is possible through: • link interfaces that are physically located on an NTIO card. The FE/GE ports. subtending. are available as network interfaces. 1-14 May 2012 Alcatel-Lucent 7360 ISAM FX R04. or user links. or user links respectively. The NTIO card contains an NT equipment protection switch per external link interface. The IHub has at least 28 ports with various specializations. or for connecting directly to users. subtending. Link protection and NT equipment protection can be performed independently from each other for links terminated on the NTIO. or optical GE. Figure 1-9 shows how the 7360 ISAM FX system can be managed in a network. connected via bidirectional P2P high-speed connections on the backplane to both NT cards These interfaces can also be used as electrical FE or GE interfaces. interfaces to subtended DSLAM systems.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide .1 — System overview Physical port number Logical port number LT slot number (index based) Faceplate port number Interface — 13 — X3 (NT-B) SFP+ — 14 — X4 (NT-B) SFP+ — 4 — IEEE1588 (NT-B) — (2 of 2) IHub The IHub provides L2 bridging (based on VPLS) and IP routing (based on VPRN). TL1 is used for pre-provisioning of the NT cards. such as the Alcatel-Lucent 5520 AMS. Figure 1-10 shows the management topology for the 7360 ISAM FX. Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 1-15 . CLI is used to manage both the xHub subsystem and the IACM.1 — System overview Figure 1-9 7360 ISAM FX network management ISAM EMS Remote CT CLI (via Telnet) TL1 (via UDP-login) CT RS232 IACM EMAN LIM LIM xHub LIM Network Ports Management Flow to cascaded ISAM 20768 The remote craft terminal (CT) uses TL1 commands or command line interface (CLI) commands. This agent implements CLI commands for the NT controller / LIMs and the xHub subsystem. It is also possible to use a local TL1 or CLI craft terminal on the NT card to manage the LT cards. These can be managed using an element management station (EMS). An integrated CLI approach is implemented on the NT card using a CLI agent. However.g. AMS 5520) SNMPv2 or SNMPv3 UDP SNMP agent ISAM SSH TL1 agent TL1 CT RS232 CLI Terminal SSH Telnet CLI CT RS232 CLI agent Debug Terminal UDP Debug agent 20767 The NT controller and the xHub subsystem each contain a separate SNMP agent. Table 1-9 shows an overview of the involved managers. Figure 1-10 7360 ISAM FX management topology EMS TL1 Gateway TL1 Terminal (e. there is no semantic integration. For LSMs. including the appliques. Card planning is supported for all types of cards. SyncE support. CO equipment management CO equipment only supports configurations consisting of a single rack and shelf. which must be configured (if different than 4093) on both the IHub subsystem as on the NT. depending on the detected type. Note 2 — VLAN 4094 is reserved for internal communication and cannot be used in any Ethernet network in which the 7360 ISAM FX system is deployed. 1. The following 7360 ISAM FX type is defined: • LNWW: large new equipment practice worldwide market (6 racks. 4 shelves per rack) Shelves are automatically planned upon detection. dimensioning information. and OLT service and system capacity. Ethernet frame size. This happens through a dedicated VLAN. 1-16 May 2012 Alcatel-Lucent 7360 ISAM FX R04. IWF capabilities. Note 1 — External OAM VLAN: The IHub subsystem supports in-band management. A complete overview of all supported card types in each type of shelf is in the chapter 2 “Shelves”. The NE equipment practice type does not have to be explicitly planned by the operator. CT Craft terminal using TL1 commands or command line interface (CLI) commands. The operator can control the administrative state of a shelf (lock/unlock). The NE manages different types of cards.1 — System overview Table 1-9 Manager overview Type Description EMS Element management system (EMS) based on SNMP. the operator can control the administrative state (lock/unlock). the NT will auto-plan the maximum number of racks supported by this equipment practice. The Alcatel-Lucent work station (5520 AMS) is commonly used. ONT management For more information about the ONT management.5 Equipment management This section describes the 7360 ISAM FX general equipment practice including CO equipment management. At the same time. see System Description for FD 100/320Gbps NT and FX NT. but is auto-planned by the NT at startup.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide . Table 1-10 NT card dimensioning Description FANT-F Throughput 480 Gbps Maximum number of MAC addresses (FDB)(1) 128 k Maximum number of IP interfaces ARP table size Maximum number of IP routes: 512 IPv4 16 k IPv6 8k IPv4 IPv6 FIB 16 k RIB 16 k FIB 8k RIB 8k Maximum number of L2 filters 512(2) Maximum number of L3 filters 512 Maximum number of VLANs 4k Maximum number of cross-connects 4k Maximum number of ONTs 16 Maximum number of UNIs 19584 Maximum number of VLAN ports 103680 Maximum number of CC VLAN 49152 Maximum number of (active) MC streams 2k Maximum number of L2-terminated VLAN 3072 L2 frame size (in bytes) 2048 External interfaces 1 x El. see Table 1-10 SyncE support on NT cards and NTIO cards. see Table 1-14 GPON-specific dimensioning. see Table 1-11 the IWF capabilities of the LT cards per forwarding type. see Table 1-13 dimensioning information of the LT cards per forwarding type.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 1-17 . see Table 1-15 NT card dimensioning Table 1-10 lists the dimensioning for the NT cards and their variants. see Table 1-12 Ethernet frame size. GE 4 x 1/10 GE BITS in/out ports 1/1 SyncE input/output 4/4 (1 of 2) Alcatel-Lucent 7360 ISAM FX R04.6 Card capabilities and dimensioning This section provides an overview of: • • • • • • dimensioning information for the NT cards.1 — System overview 1. The ToD serial output and 1PPS signals are processed by the NT cards and are distributed to the LT cards through the backplane signals of the 7360 ISAM FX system to allow the collection of precise ToD information that can be measured on both the ToD/1PPS interface on the NT card. See Table 1-4 for an overview of the supported LT cards. (2) The same resource is shared for L2 filters and L3 filters. Table 1-12 IWF capabilities Feature L3 L3 GPON NELT-B UNI NNI ATM AAL5 encapsulation type LLC/SNAP bridged (IPoE and PPPoE) Y — — — LLC/SNAP routed (IPoA) Y — — — LLC/NLPid (PPPoA) Y — — — (1 of 3) 1-18 May 2012 Alcatel-Lucent 7360 ISAM FX R04. and on the system backplane. SyncE support Table 1-11 lists the port applicability of the SyncE NTR functionality for clock extraction (in) and generation (out). So. Table 1-11 Faceplate port applicability for SyncE Card Port SyncE in support SyncE out support FANT-F X1 1 GE and 10 GE 1 GE and 10 GE X2 1 GE and 10 GE 1 GE and 10 GE X3 1 GE and 10 GE 1 GE and 10 GE X4 1 GE and 10 GE 1 GE and 10 GE IEEE 1588v2 PTP support The IEEE 1588v2 precise time protocol provides an upgraded architecture to improve syncronization accuracy and allow precise ToD information to be distributed within the NT and LT cards in a 7360 ISAM FX shelf. IWF capabilities Table 1-12 lists the IWF capabilities of the LT cards.1 — System overview Description FANT-F IEEE1588 slave for frequency synchronization Y (2 of 2) Notes (1) A number of MAC addresses are always used by the system for internal purposes.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide . the maximum cannot be obtained for both at the same time. VC Mux PPPoA) Y — — — Auto-detect IP+PPP Y — — — Auto-detect PPPoA (between LLC-NLPID and VC Mux PPPoA) Y — — — Reception of untagged packets Y — Y Y Reception of combination of untagged and priority-tagged packets Y — Y Y Reception of single-tagged packets Y Y Y Y Reception of combination of untagged. single-tagged packets Y Y Y Y Port-based default VLAN for untagged/priority-tagged (if applicable) packets Y Y Y Y Port. PPPoE and IpoE) Y Y Y Y CC mode: protocol filter Y Y — Y CC mode: IPoA to IPoE CC Y — — — VLAN stacking (S-VLAN CC and S-VLAN/C-VLAN CC) Y Y Y Y VLAN stacking (S-VLAN/C-VLAN residential bridge) — — — — QoS-aware CC Y — — — ARP: enabling/disabling broadcast Y Y Y — 802.and protocol-based default VLAN for untagged/priority-tagged packets of the IpoE protocols Y Y Y Y Port.1 — System overview Feature L3 L3 GPON NELT-B UNI NNI VC Mux bridged (IPoE and PPPoE) Y — — — VC Mux routed (IPoA) Y — — — VC Mux PPPoA (PPPoA) Y — — — Auto-detect IP (between LLC/SNAP bridged and routed) Y — — — Auto-detect PPP (between LLC/SNAP bridged.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 1-19 . VC Mux bridged and LLC-NLPID.1X authentication Y Y Y — Encapsulation autodetect Bridged encapsulation Ethernet packet formats Packet processing L2 Forwarding L2 Forwarding user access protocols (2 of 3) Alcatel-Lucent 7360 ISAM FX R04. priority-tagged.and protocol-based default VLAN for untagged/priority-tagged packets of the PPPoE protocols Y Y Y Y Priority-bit re-marking and mapping table for tagged/priority-tagged packets Y Y Y Y RB mode: protocol filter (set of Ethertypes) for upstream traffic in VLANs in (PPPoE and IpoE) Y Y Y Y RB mode Ethernet packet types: Ethernet II encap on Ethernet Y Y Y Y RB mode Ethernet packet types: LLC/SNAP on Ethernet Y Y Y Y CC mode: transparently pass all encapsulations (for example. Ethernet frame size Table 1-13 lists the supported Ethernet frame size for the LT cards.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide .1X authentication Y — Y — ARP proxy user side for IPoE Y Y — — DHCP relay Y — Y — CAC profile Y Y Y Y Association of QoS profiles to ports Y Y Y Y Association of QoS profiles to port-VLAN associations Y Y Y Y Sub-flow counters — Y — — VLAN termination (at network side). not on L3 LT cards with 2. forwarding at Layer 3 L3 Forwarding user access protocols QoS (2) (3 of 3) Notes (1) IP aware bridge is only supported on L3 LT cards with 1GE NT interface. Table 1-13 Ethernet frame size for LT cards 1-20 LT card Encapsulation Frame size (bytes) P2P Ethernet NELT-B UNI (with FCS) 1976 NELT-B NNI (with FCS) 2048 OLT FGLT-A (with FCS) 2000 OLT NGLT-A (with FCS) 2000 OLT NGLT-C (with FCS) 2000 May 2012 Alcatel-Lucent 7360 ISAM FX R04.5GE NT interface GPON LT cards and NELT-B (2) Support policing on bridge port on L2.1 — System overview Feature L3 L3 GPON NELT-B UNI NNI DHCP option 82 insertion Y Y Y — PPPoE relay tag Y Y Y — PPPoA-PPPoE relay Y — — — Multicast services access control Y Y Y — Multicast services resource control Y Y Y Y L3 Forwarding IPoE (1) Y Y Y — IPoA (1) Y Y Y — Y Y Y — 802. Table 1-14 LT card dimensioning information Feature L3 L3 GPON NELT-B UNI NNI — — General Maximum number of PONs (2) — 8 16 Maximum number of UNIs — 4096 — — Maximum number of FE ports per card — — 36 36 Maximum number of GE ports per card — — 36 36 Maximum number of UNI port type (FE) per card — — 36 — Maximum number of UNI port type (GE) per card — — 36 — Maximum number of NNI port type (FE) per card — — — 36 Maximum number of NNI port type (GE) per card — — — 36 Maximum number of CC VLAN 768 11 520 4608 4608 Maximum number of RB VLAN 768 1296 1296 1296 Maximum number of VLAN per PVC 16 8 — — Maximum number of port-VLAN associations per LT 384 11 520 144 4608 Maximum number of VLAN port per UNI (FE/GE) — — 8 — Maximum number of VLAN port per NNI (FE/GE) — — — 256 Maximum number of MAC addresses per VLAN port 64 64 — — Maximum number of MAC addresses per UNI — — 64 — Maximum number of MAC addresses per NNI — — — 3072 Maximum number of MAC addresses per LT (including static) 1024 16 K(1) 2304 32768 Maximum number of user IP addresses per LT (including static) 384 8K — — Average number of IPv4 subnets or addresses per card (=Average IP anti-spoofing entries.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 1-21 . full/32 IP address or subnet. See Table 1-4 for an overview of the supported LT cards.1 — System overview Dimensioning of the LT cards Table 1-14 lists the dimensioning information for the LT cards. per card — — 288 0 Maximum number of IPv4 hosts per card — — 288 0 (1 of 2) Alcatel-Lucent 7360 ISAM FX R04. ISAM OLT service and system capacity This section provides information about the 7360 ISAM FX service and system capacities. Service and system capacities Table 1-15 lists dimensioning information specific to the GPON functionality. (2) Dependant on variant of LT card. distance.1x sessions per UNI — — 1 — Maximum number of 802. Table 1-15 GPON-specific dimensioning information 1-22 Feature L3 GPON Maximum number of ONT per PON 128 Maximum number of UNIs per PON 288 Maximum number of TCONTs per PON 1024 Maximum number of GEM ports per PON 2048 May 2012 Alcatel-Lucent 7360 ISAM FX R04.1 — System overview Feature L3 L3 GPON NELT-B UNI NNI Maximum number of IPv6 subnets or addresses per UNI — — 16 0 Maximum number of IPv6 subnets or addresses per VLAN port — — 4 0 Maximum number IPv6 host addresses per card — — 288 0 Maximum number of VRFs per LT 128 N\A — — Maximum number of simultaneous multicast channels per LT 1024 1024 1024 1024 Maximum number of multicast groups per user 100 100 100 1024 Maximum number of multicast VLANs 128 64 — — Maximum number of 802. and ISAM OLT performance.1x (2 of 2) Notes (1) A few MAC addresses are used by the system for internal purposes. FGLT-A:16. NGLT-A/NGLT-C:8.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide .1x sessions per PON — 288 — — Maximum number of 802. and connection capacities.1x sessions per card — 2304 36 — Multicast dimensioning 802. which results in the following redundancy cases: • only link protection: • • • • single NT. The loss characteristic is determined by the difference between the optical transmitter and optical receiver for each direction. The optical link budget is defined by both loss and bandwidth characteristics.1 — System overview ISAM OLT performance and distance The P-OLT provides performance and distance capacity of 2. NTIO card with link switches NT protection.488 Gb/s downstream and 1. for all NGLT cards. and is limited by the smaller of the upstream and downstream values. The bandwidth characteristic is determined by the maximum link distance parameter of each OLT and ONT transmitter specification. and is typically 28 dB. Table 1-16 describes the total number of ports per LT card. no NTIO: dual active/standby NT. single NTIO: dual active/standby NT. The number of ports depends on the LT card used. no NTIO: single. with direct uplink or link set decoupled NT and link protection.7 Card type Number of ports per card Totalnumber of ports FGLT-A 16 256 NGLT-A 8 128 NGLT-C 8 128 NT redundancy support Four levels of redundancy are supported: • • • • link redundancy equipment redundancy subscriber line redundancy application redundancy NT redundancy implements link redundancy and equipment redundancy in a decoupled architecture. or load-sharing uplinks combined NT and link protection. ISAM OLT connection capacities The ISAM OLT can accommodate a maximum of 16 LT cards. passive link protection. Table 1-16 Total number of ports per LT card 1. active-standby. within a 30 km (18. active-standby or load sharing uplinks subtending system protection Table 1-17 lists the hardware modules that are ready for NT redundancy support.244 Gb/s upstream. Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 1-23 .6 mi) span. commonlanguage.1 — System overview Table 1-17 NT Redundancy support-ready hardware modules Type Module Shelf NFXS-D NFXS-E NFXS-F NT cards FANT-F LT cards NELT-B NGLT-A NGLT-C FGLT-A 1. Table 1-18 CLEI codes Mnemonic Variant CLEI code CPR Bar code AFAN-E 3FE 65060 AA VAUCAJ86AA 072AXJ 178692 AFAN-H 3EC 37533 NB VAUCAE2KAA 070LXX 154967 AFAN-X 3FE 64994 AA VAUCAJ56AA 072ARC 178361 FANT-F 3FE 53701 BD VAI2AHVNAA 072DJP 182107 FGLT-A 3FE 66721 AA — — — NELT-B 3FE 62543 AA VAUCAJ36AA 072AEY 177909 NFXS-D 3FE 65209 BA VAMZ600BRA 215138 463997 NFXS-E 3FE 64936 BA VAMZ400BRA 215136 463993 NFXS-F 3FE 64991 BA VAMZ500BRA 215137 463996 NGFC-G 3FE 65676 AA VAUCAK26AA — — NGFC-H 3FE 65675 AA VAUCAK36AA — — (1 of 2) 1-24 May 2012 Alcatel-Lucent 7360 ISAM FX R04. Table 1-18 lists the cards and fan units for which CLEI codes are available.asp?app=clei_inq uiry An account is required before the CLEI database can be accessed.8 CLEI codes This sections provides the currently available CLEI codes. The latest status of these CLEI codes is always available on the following website: https://codecenter. an adaptation to a card) occurs.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide . Caution — The CLEI code changes whenever an item change (that is.com/applogin. 1 — System overview Mnemonic Variant CLEI code CPR Bar code NGLT-A 3FE 64279 AA VAI2AFHDAA 070YVT 175498 NGLT-C 3FE 67301 AA — — — (2 of 2) Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 1-25 . 04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide .1 — System overview 1-26 May 2012 Alcatel-Lucent 7360 ISAM FX R04. 4 Dummy front panels Alcatel-Lucent 7360 ISAM FX R04.2 — Shelves 2.3 Supported plug-in units 2.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 2-2 2-7 2-8 2-1 .1 Overview 2-2 2.2 7360 ISAM FX shelves 2. 5 mm 482.1 Overview This chapter provides information about the different 7360 ISAM FX shelves supported for ANSI. 8. 13. The 7360 ISAM FX system for R4. shelf configurations. and drip tray. 19 in.51 in.00 in. baffles. each shelf operates and is managed as a separate system. 10. Multiple collocated shelves can be cascaded using the standard FE. Shelf types Table 2-1 lists the 7360 ISAM FX shelves supported. EIA standard racks N Y(1) Y(1) 23 in.x is a one-shelf system. The basic building blocks of the 7360 ISAM FX system are the shelves. 2-2 May 2012 Alcatel-Lucent 7360 ISAM FX R04.5 mm 20. Daisy-chaining multiple shelves using extender cards is not supported.3 mm 278. 2. fan unit.2 7360 ISAM FX shelves This section provides general information about the 7360 ISAM FX shelf types.83 in. 280 mm 278. NT redundancy.5 mm 355 mm 222 mm 24. 19.02 in. 622.00 in. In such a configuration. The modular organization of the 7360 ISAM FX system allows a wide range of physical size and traffic capacity options. racks Y(1) Y(1) Y(1) Note (1) Specific mounting kits must be used.98 in. and 10 GE subtending links.3 mm 11. Table 2-1 7360 ISAM FX shelves supported Item Shelves 7360 ISAM FX16 7360 ISAM FX8 7360 ISAM FX4 Code 3FE 65209 BA 3FE64936 BA 3FE-64991 BA Mnemonic NFXS-D NFXS-E NFXS-F Dimensions Width Height Depth Can be mounted in: 529 mm 482.96 in.74 in. See Table 2-3 for mounting kit requirements. 19. GE.96 in.2 — Shelves 2. 10. max.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide . Figure 2-1 shows the 7360 ISAM FX-16 shelf. 2 — Shelves Figure 2-2 shows the 7360 ISAM FX-8 shelf. Figure 2-3 shows the 7360 ISAM FX-4 shelf. Figure 2-1 7360 ISAM FX-16 shelf Card cage area 02 03 04 05 BO N D I N G 07 08 NTA Energy Hazard A/70 FOR LT NTIO NTB 09 11 12 7360 ISAM FX-16 B/70 FOR LT -48V 70A 10 ON A R T H OFF ON E ESD 06 OFF N594 I N T 01 General function and control unit 14 15 BAT A MAJOR BAT B MINOR ACO 16 PO Fan unit ALM Power unit and cable connection area 13 CRITICAL Energy Hazard BITS INTERFACE NT-A NT-B TIME OF DAY 1 Hz-PULSE RING TIP FRAME GND CRAFT PORT TB 1-1 -4 T A BA 8V TB 1-2 TN TR BA A TB 1-3 TN TR BA B TB 1-4 -4 CO ALARMS T B BA 8V 22120 Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 2-3 2 — Shelves 04 05 06 07 08 Figure 2-2 7360 ISAM FX-8 shelf NTB NTIO NTA N594 7360 ISAM FX-8 B-40A Energy Hazard Alarms GND NTB Remote Craft BITS External Alarms FAN Critical Major Minor A-40A NTA 7360 ISAM FX-8 01 02 03 Card cage BAT A BAT B ACO General facilities card Fan unit 21957 02 03 04 Figure 2-3 7360 ISAM FX-4 shelf NTIO NTA 7360 ISAM FX-4 NTB 01 Card cage External Alarms BITS TOD/IHZ Remote Craft N594 7360 ISAM FX-4 NTA GND NTB General facilities card BAT A BAT B FUSE A B 1 2 3 Critical Alarms Major ACO Minor FAN Fan unit 22436 Shelf configurations Table 2-2 lists the shelf configurations. 2-4 May 2012 Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide 2 — Shelves Table 2-2 Shelf configurations Configuration 7360 ISAM FX-16 7360 ISAM FX8 7360 ISAM FX4 Maximum number of LT cards 16 8 4 Maximum number of NT cards 2 2 2 Maximum number of NTIO cards 1 (optional) 1 (optional) 1 (optional) The following figures show the general layout and the slot numbering for the 7360 ISAM FX shelves: Figure 2-4 shows the 7360 ISAM FX-16. Figure 2-5 shows the 7360 ISAM FX-8. Figure 2-6 shows the 7360 ISAM FX-4. Figure 2-4 Shelf configuration of 7360 ISAM FX-16 LT LT LT LT LT LT LT LT NT NTIO NT LT LT LT LT LT LT LT LT 1 2 3 4 5 6 7 8 A B 9 10 11 12 13 14 15 16 CBs, LEDs and switches Fan unit Connectors 22131 Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 2-5 Baffle kits. and 1:1 (active/standby) in the control and management plane. Specific mounting kits may be required for installation of the 7360 ISAM FX-8 and 7360 ISAM FX-4 shelves.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide . The fan unit can be equipped with a fan filter. with either one or two shelves. depending on the rack mounting configuration. mounting bracket kits. and the required screws are all included.2 — Shelves Figure 2-5 Shelf configuration of 7360 ISAM FX-8 LT 8 LT 7 LT 6 LT 5 LT 4 LT 3 LT 2 LT 1 NT B FAN NT I/O NT A NGFC-H 21959 Figure 2-6 Shelf configuration of 7360 ISAM FX-4 LT 4 LT 3 LT 2 LT 1 NT B FAN NT I/O NT A NGFC-G 22406 NT redundancy The protection scheme for NT redundancy is 1+1 (active/active) in the data plane. The number of kits provided depends on the rack mounting configuration required. 2-6 May 2012 Alcatel-Lucent 7360 ISAM FX R04. The fan unit is a field-replaceable unit in the shelf fan area and plugs directly into the backplane. Fan unit One fan unit provides forced air cooling in the shelf. Shelf mounting kits The mounting kits required for installation of 7360 ISAM FX-16 shelves are included with the shipment. and loose particles that may cause damage to equipment. See Figure 2-7. Factory-installed fiber optic cabling ring-guides are used for proper fiber optic cable handling. rack with horizontal mount mounting brackets -not required mounting screws -required • mounting brackets -not required mounting screws -required Shelf mounting kit required Shelf mounting kit required Includes: Includes: • • • mounting brackets -required mounting screws -required • mounting brackets -required mounting screws -required Heat and fiber management baffle A heat and fiber management baffle is installed with the 7360 ISAM FX-16 shelf for safety protection from heat.3 Supported plug-in units Table 2-4 lists the supported plug-in units in the 7360 ISAM FX shelves. EIA rack with horizontal mount Shelf mounting kit optional Shelf mounting kit optional Includes: Includes: • • • 23 in. possible flame spread. Table 2-3 Mounting options/kits for 7360 ISAM FX shelves Type of rack / mount 7360 ISAM FX-4 7360 ISAM FX-8 19 in. Figure 2-7 Heat and fiber management baffle for 7360 ISAM FX-16 22373 2. Alcatel-Lucent 7360 ISAM FX R04. See the 7360 ISAM FX Hardware Installation Manual for more information.2 — Shelves Table 2-3 describes the mounting options and mounting kits available.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 2-7 . 2 — Shelves Table 2-4 Supported plug-in units in 7360 ISAM FX shelves Slot Plug-in Unit Description NTA FANT-F 480 Gbps NT card NTB FANT-F 480 Gbps NT card LT slot NELT-B 36-line Ethernet (FE/GE) LT card NGLT-A GPON LT card with 8 GPON interfaces NGLT-C GPON LT card with 8 GPON interfaces FGLT-A GPON LT card with 16 GPON interfaces NGFC-G GFC for 7360 ISAM FX-8 shelf NGFC-H GFC for 7360 ISAM FX-4 shelf AFAN-H NB Fan unit for 7360 ISAM FX-16 shelf AFAN-E Fan unit for 7360 ISAM FX-8 shelf AFAN-X Fan unit for 7360 ISAM FX-4 shelf General facilities card Fan area Note — For more information about the plug-in units.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide . see the relevant UDS. The mnemonics that are used are explained in Appendix A. Figure 2-8 shows the dummy front panel for an NT card. the dummy front panel is replaced by the appropriate card and the cables are connected to the card. 2. optical LT cards. Dummy front panels must be mounted on any unused slot of a shelf to ensure: • EMC compliance • thermal compliance via a correct airflow in the shelf • safety by avoiding direct contact with backplane connectors When a slot is provisioned. 2-8 May 2012 Alcatel-Lucent 7360 ISAM FX R04. and NTIO cards. For NT cards A dummy front panel must be used when the second NT card is not installed.4 Dummy front panels This section describes the 7360 ISAM FX shelf dummy panels (filler plates) for NT cards. Figure 2-9 shows the dummy front panel for optical LT cards. NGLT-C. Alcatel-Lucent 7360 ISAM FX R04. FGLT-A).04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 2-9 .2 — Shelves XX XX XX XXXXXXX Figure 2-8 Dummy front panel for NT card 22197 For optical LT cards A dummy front panel must be used when an LT card is not installed (NGLT-A. 2 — Shelves Figure 2-9 Dummy front panel for optical LT card Dust cap 22198 For NTIO card A dummy front panel must be used when the NTIO card is not installed. Figure 2-10 shows the universal dummy front panel for an NTIO card. 2-10 May 2012 Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide . 2 — Shelves Figure 2-10 Universal dummy front panel for NTIO card 22429 Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 2-11 . 2 — Shelves 2-12 May 2012 Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide . 5 7360 ISAM FX-4 rack mounting configurations 3-8 Alcatel-Lucent 7360 ISAM FX R04.2 Rack equipment 3-2 3.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 3-1 .3 7360 ISAM FX-16 rack mounting configurations 3-3 3.3 — Rack mounting configurations 3.4 7360 ISAM FX-8 rack mounting configurations 3-5 3.1 Overview 3-2 3. 1 mm) For more information about 7360 ISAM FX equipment and the supported racks and rack mounting configurations. baffles. shelves. Parts can also be delivered separately or in kits.9 mm) 23 in.2 Rack equipment This section briefly describes the 7360 ISAM FX rack equipment and assembly. See Chapter 6 for ordering information.75 in. The rack assembly includes a rack. Table 3-1 7360 ISAM FX supported rack equipment Size of rack Shelf apeture between rack uprights EIA standard 19 in. rack 17. see the 7360 ISAM FX Hardware Installation Manual. and drip tray assembly kits. Note 2 — See 7360 ISAM FX Hardware Installation Manual for more information about how to install the equipment. Each rack configuration is ordered with a specific ordering code. 3.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide . rack 21.5 in. where the assembly is done on site at the customer location. 3-2 May 2012 Alcatel-Lucent 7360 ISAM FX R04. (546. the racks are optional for the 7360 ISAM FX-8 and 7360 ISAM FX-4 rack mounting configurations. however. dependent on the rack configuration required and currently supported. Table 3-1 lists the 7360 ISAM FX system rack equipment that can be used. (450. accompanying fan units. The rack equipment can be delivered as a pre-assembled rack or in separate kits. The 7360 ISAM FX-16 rack mounting configurations include the rack.3 — Rack mounting configurations 3.1 Overview This chapter describes the rack equipment and the supported rack mounting configurations for the following 7360 ISAM FX shelves: • 7360 ISAM FX-16 • 7360 ISAM FX-8 • 7360 ISAM FX-4 Note 1 — See chapter 6 for part numbers. The 7360 ISAM FX-16 can be installed vertically in a 23 in. An example of a configuration is shown in Figure 3-1. Table 3-2 Rack mounting configurations for 7360 ISAM FX-16 FEMA code 3FE 66742 AA Rack unit 23 in. Table 3-2 lists the supported rack configurations for the 7360 ISAM FX-16 shelves in a 23 in.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 3-3 . rack vertical mount SR 1 NFXS-D NFXS-D Fiber and heat baffle kit Fiber and heat baffle kit Left and right mounting brackets Left and right mounting brackets Fan 1 SR 2 Fan 2 3FE 66742 AB AFAN-H AFAN-H (with fan filter) (with fan filter) — NFXS-D — Fiber and heat baffle kit — Left and right mounting brackets — AFAN-H (with fan filter) Alcatel-Lucent 7360 ISAM FX R04. rack.3 — Rack mounting configurations 3.3 7360 ISAM FX-16 rack mounting configurations This section describes the 7360 ISAM FX-16 rack mounting configurations. rack. 04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide .3 21.3 — Rack mounting configurations Figure 3-1 Rack mounting configurations for 7360 ISAM FX-16 (3FE 66742 AB) 22.5 CRAFT PORT BITS INTERFACE NT-A NT-B TIME OF DAY BITS INTERFACE NT-A NT-B TIME OF DAY 1 Hz-PULSE RING TIP FRAME GND CO ALARMS 34 RU CRAFT PORT 1 Hz-PULSE RING TIP FRAME GND CO ALARMS 22732 3-4 May 2012 Alcatel-Lucent 7360 ISAM FX R04. Alcatel-Lucent 7360 ISAM FX R04.5 in. Figure 3-3 shows the 7360 ISAM FX-8 horizontal rack mounting configurations in am EIA standard 19 in. up to five rack units are supported. rack • horizontally in a 23 in. rack horizontal mount SR 1 NFXS-E NFXS-E Shelf mounting kit Shelf mounting kit Fan 1 SR 2 AFAN-E AFAN-E (with fan filter) (with fan filter) — NFXS-E Shelf mounting kit Fan 2 — AFAN-E (with fan filter) Note (1) Although only two rack units are portrayed in this table. rack Note — A 19 in. shelf aperture between the uprights is not supported. seismic rack with a 17. EIA rack horizontal mount 23 in.3 — Rack mounting configurations 3. The 7360 ISAM FX-8 can be installed: • horizontally in an EIA standard 19 in.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 3-5 . rack. Table 3-3 lists the supported horizontal rack mounting configurations for 7360 ISAM FX-8 shelves.4 7360 ISAM FX-8 rack mounting configurations This section describes the 7360 ISAM FX-8 rack mounting configurations. Table 3-3 Horizontal rack mounting configurations for 7360 ISAM FX-8 Rack unit (1) 19 in. 312 17. 3-6 May 2012 Alcatel-Lucent 7360 ISAM FX R04.3 — Rack mounting configurations Figure 3-2 Horizontal rack mounting configurations for 7360 ISAM FX-8 in an EIA standard 19 in.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide . rack. rack 18.750 03 04 05 06 07 08 35 RU NTB NTIO NTA 7360 ISAM FX-8 01 02 8 RU 7360 ISAM FX-8 B-40A Energy Hazard Energy Hazzard Alarms NTA External Alarms GND NTB BITS FAN Critical Major Minor A-40A TOD/IHZ Remote Craft BAT A BAT B ACO 22736 Figure 3-3 shows the 7360 ISAM FX-8 horizontal rack mounting configurations in a 23 in. 3 — Rack mounting configurations Figure 3-3 Horizontal rack mounting configurations for 7360 ISAM FX-8 in a 23 in.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 3-7 .500 03 04 05 06 07 08 35 RU NTB NTIO NTA 7360 ISAM FX-8 B-40A Energy Hazard Energy Hazzard Alarms NTA GND NTB BITS FAN Critical Major Minor A-40A External Alarms 7360 ISAM FX-8 01 02 8 RU TOD/IHZ Remote Craft BAT A BAT B ACO 22734 Alcatel-Lucent 7360 ISAM FX R04. rack 22.313 21. 3 — Rack mounting configurations 3. EIA rack horizontal mount 23 in.5 in.5 7360 ISAM FX-4 rack mounting configurations This section describes the 7360 ISAM FX-4 rack mounting configurations. shelf aperture between the uprights is not supported. rack horizontal mount SR 1 NFXS-F NFXS-F Shelf mounting kit Shelf mounting kit Fan 1 SR 2 Fan 2 AFAN-X AFAN-X (with fan filter) (with fan filter) NFXS-F NFXS-F Shelf mounting kit Shelf mounting kit AFAN-X AFAN-X (with fan filter) (with fan filter) Note (1) Although only two rack units are portrayed in this table. rack Note — A 19 in. seismic rack with a 17. up to seven rack units are supported. The 7360 ISAM FX-4 shelf can be installed: • horizontally in an EIA standard 19 in. Table 3-4 lists the supported horizontal rack mounting configurations for 7360 ISAM FX-4 shelves. Figure 3-5 shows the 7360 ISAM FX-4 horizontal rack mounting configurations in an EIA standard 19 in. 3-8 May 2012 Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide . rack • horizontally in a 23 in. rack. Table 3-4 Horizontal rack mounting configurations for 7360 ISAM FX-4 Rack unit (1) 19 in. 312 17.3 — Rack mounting configurations Figure 3-4 Horizontal rack mounting configurations for 7360 ISAM FX-4 in an EIA standard 19 in. rack 18. rack. Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 3-9 .750 NTIO 5 RU NTA 7360 ISAM FX-4 NTB 01 02 03 04 38 RU External Alarms BITS N594 7360 ISAM FX-4 NTA GND NTB TOD/IHZ Remote Craft BAT A BAT B FUSE A B 1 2 3 Critical Alarms Major ACO Minor FAN 22740 Figure 3-5 shows the 7360 ISAM FX-4 horizontal rack mounting configurations in a 23 in. 500 02 03 04 38 RU NTIO NTA 7360 ISAM FX-4 NTB 01 5 RU External Alarms BITS N594 7360 ISAM FX-4 NTA GND NTB TOD/IHZ Remote Craft BAT A BAT B FUSE A B 1 2 3 Critical Alarms Major ACO Minor FAN 22738 3-10 May 2012 Alcatel-Lucent 7360 ISAM FX R04.3 — Rack mounting configurations Figure 3-5 Horizontal rack mounting configurations for 7360 ISAM FX-4 in a 23 in.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide . rack 22.313 21. 04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 4-2 4-1 .4 — Optical modules 4.2 Characteristics Alcatel-Lucent 7360 ISAM FX R04.1 Overview 4-2 4. 10 km 0.342 mi 16 −40°F to 185°F 3FE 29194 AA 3FE 29194 BA 3FE 29195 AA 3FE 63343 AA FE BX10-D FE BX10-D FE BX10-U 100Base-T Tx: 1550 −40°C to 85°C Rx: 1310 −40°F to 185°F Tx: 1490 −40°C to 85°C Rx: 1310 −40°F to 185°F Tx: 1310 −40°C to 85°C Rx: 1550 −40°F to 185°F — 0°C to 70°C 15 km 9.9 mi 24 −40°F to 185°F 80 km 49.2 mi 14 10 km 6. See Chapter 6.34 mi 40 km 24.06 mi — −40°F to 185°F 0.10 km 0.7 mi (1 of 4) 4-2 May 2012 Alcatel-Lucent 7360 ISAM FX R04.55 km 0.2 mi — 32°F to 188°F 0. 4.2 Characteristics Table 4-1 describes the Alcatel-Lucent approved optical modules for the 7360 ISAM FX.06 mi Gigabit Ethernet SFPs 3FE 25773 AA GE-SX 850 −40°C to 85°C 7 −40°F to 185°F 3FE 25774 AA GE-LX 1310 −40°C to 85°C 11 −40°F to 185°F 3FE 25775 AA GE-EX 1310 −40°C to 85°C GE-ZX 1550 −40°C to 85°C CAAA 10 km 6. Table 6-12 for part numbers and the cards that these modules support. Table 4-1 Characteristics of approved optical modules Part number Description Wavelength (nm) Operating case temperature range Optical budget (dB) Reach Fiber Bidi / uni UDS(1) 1310 −40°C to 85°C 12 0.062 mi Copper SFPs 3FE 28784 AA 1000Base-T — 0°C to 85°C — 32°F to 188°F 3FE 64927 AA 1000Base-T — −40°C to 85°C 0.4 — Optical modules 4.1 Overview This chapter describes the Alcatel-Lucent approved SFP and XFP optical modules for the 7360 ISAM FX.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide .2 mi 18 −40°F to 185°F 3FE 25776 AA 0.2 mi 14 10 km 6.3 mi 14 10 km FAAA 6.550 km MM Uni DAAA SM Uni SM Bidi SM Bidi SM Bidi Cat5 — PAAA Cat5 — EAAA Cat5 — MM Uni SM Uni SM Uni SM Uni Fast Ethernet SFPs 3FE 25777 AA FE-FX −40°F to 185°F 3FE 25778 AA FE-LX10 1310 −40°C to 85°C 0.100 km 0. 062 mi SFP+s (2 of 4) Alcatel-Lucent 7360 ISAM FX R04.4 — Optical modules Part number Description Wavelength (nm) Operating case temperature range Optical budget (dB) Reach Fiber Bidi / uni UDS(1) 3FE 25771 AA GE-YX CWDM (24 dB) 1471 −40°C to 85°C 22 62 SM Uni AAAA 1491 −40°F to 185°F 31 120 SM Uni 10 km SM Bidi SM Bidi SM Bidi SM Bidi Cat5 — 3FE 25771 AB 3FE 25771 AC 1511 3FE 25771 AD 1531 3FE 25771 AE 1551 3FE 25771 AF 1571 3FE 25771 AG 1591 3FE 25771 AH 1611 3FE 25771 CA 3FE 29549 CA GE-VX CWDM (32 dB) 1471 −5°C to 85°C 1491 32°F to 185°F 3FE 29550 CA 1511 3FE 29551 CA 1531 3FE 29552 CA 1551 3FE 29553 CA 1571 3FE 29554 CA 1591 3FE 29555 CA 1611 3FE 25772 AA 3FE 25772 AB 3FE 28785 AA 3FE 25785 AB 3FE 28784 AA GE-BX10-U GE-BX10-D GE-BX40-U GE-BX40-D 1000Base-T Tx: 1310 −40°C to 85°C Rx: 1490 −40°F to 185°F Tx: 1490 −40°C to 85°C Rx: 1310 −40°F to 185°F Tx: 1310 −40°C to 85°C Rx: 1550 −40°F to 185°F Tx: 1550 −40°C to 85°C Rx: 1310 −40°F to 185°F — 0°C to 85°C 32°F to 188°F 9 GAAA 6.9 mi — 0.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 4-3 .9 mi 19 40 km 24.2 mi 9 10 km 6.2 mi 19 40 km 24.100 km EAAA 0. 2 mi 9 10 km 6.5 km 0.19 mi −40°F to 185°F 3FE 65831 AA 10 km 6.2 mi Tx: 1550 0°C to 70°C Rx: 1310 32°F to 188°F 14 10 km FE-BX10-D Tx: 1490 −40°C to 85°C 8 (FE) 10 km GE-BX10-D Rx: 1310 −40°F to 185°F 9 (GE) 6.3 mi E1 SFPs 3FE 67231 AA E1/T1 SFP — −40°C to 65°C — −40°F to 149°F E1/T1: short haul 0.3 mi Dual SFPs 3FE 65106 AA 3FE 65106 DA 3FE 65107 AA 3FE 65107 DA 3FE 66131 AA GE-BX10-D GE-BX10-D FE-BX10-D FE-BX10-D Tx: 1490 −40°C to 85°C Rx: 1310 −40°F to 185°F Tx: 1490 0°C to 70°C Rx: 1310 32°F to 188°F Tx: 1550 −40°C to 85°C Rx: 1310 −40°F to 185°F 9 10 km 6.2 mi 10 32°F to 185°F 3FE 62600 DA 10 GE-R 1310 0°C to 70°C 6.2 mi 32°F to 188°F 3FE 63264 AA 10 km 6.2 mi −40°F to 185°F 3FE 65608 AA 10 km 40 km 24.4 — Optical modules Part number Description Wavelength (nm) Operating case temperature range Optical budget (dB) Reach Fiber Bidi / uni UDS(1) 3FE 62600 AA 10 GE-R 1310 −40°C to 85°C 10 10 km SM Uni MAAA SM Uni SM Uni SM Uni MM Uni MM Uni SM Uni SM Uni — Uni XAAA SM Bidi TAAA SM Bidi SM Bidi SM Bidi SM Bidi −40°F to 185°F 3FE 62600 CA 10 GE-R 1310 −5°C to 85°C 6.2 mi 14 10 km 6.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide .2 mi 6.3 km 0.9 mi 24 −40°F to 185°F 80 km 53.19 mi 15 −40°F to 185°F 3FE 65832 AA 0.31 mi E1/T1: long haul 2.2 mi (3 of 4) 4-4 May 2012 Alcatel-Lucent 7360 ISAM FX R04.1 km 1.2 mi 10 32°F to 188°F 3FE 62600 EA 10 GE-R 1310 −40°C to 85°C 10 GE-R 850 0°C to 70°C 10 10 GE-R 850 −40°C to 85°C 11 10 GE-R 1550 −40°C to 85°C 11 10 GE-R 1550 −40°C to 85°C 0.3 km 0. 6 mi 28 30 km 18.2 mi SM Bidi SM Bidi SM Bidi SM Bidi SM Bidi UDS(1) 8 100BaseBX10 GPON SFP 3FE 53441 AA 3FE 53441 AC 3FE 53441 BA 3FE 53441 CC 3FE 53441 DA Class B+. Alcatel-Lucent 7360 ISAM FX R04.3 mi 28 30 km 18. see UDS 3HH 01046 xxxx TQZZA. with OTDR Tx: 1490 −5°C to 70°C Rx: 1310 23°F to 188°F XG-PON1 OLT XFP Tx: 1577 −5°C to +70°C Rx: 1270 +23°F to +185°F XG-PON1 ONU SFP+ Tx: 1577 −40°C to +85°C Rx: 1270 −40°F to +185°F TM1 SFP — −40°C to 70°C 28 30 km RAAA 18. where xxxx is the document variant indicated in this column.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 4-5 .6 mi 32 60 km 37. normal Tx: 1490 −5°C to 70°C Rx: 1310 23°F to 188°F Class B+ with OTDR Tx: 1490 −40°C to 85°C Rx: 1310 −40°F to 185°F Class C+. normal Tx: 1490 −5°C to 70°C Rx: 1310 23°F to 188°F Class B+.6 mi 32 60 km 37.3 mi XG-PON XFPs/SFPs 3FE 53971 AA 3FE 53972 AA 29 dB 40 km SM Bidi 29 dB 40 km SM Bidi SM Uni YAAA Other 3FE 66247 AA 28 WAAA −40°F to 158°F (4 of 4) Note (1) For more information about the characteristics of the SFP module. normal Tx: 1490 −40°C to 85°C Rx: 1310 −40°F to 185°F Class C+.4 — Optical modules Part number Description Wavelength (nm) Operating case temperature range Optical budget (dB) Reach Fiber Bidi / uni 3FE 66131 DA FE-BX10-D Tx: 1490 0°C to 70°C 9 10 km SM Bidi GE-BX10-D Rx: 1310 32°F to 188°F 1000BaseBX10 6. 4 — Optical modules 4-6 May 2012 Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide . Planning and ordering 5 — Planning the equipment 6 — Ordering the equipment Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 . 04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide .May 2012 Alcatel-Lucent 7360 ISAM FX R04. 3 Rack considerations 5-4 5.9 Power considerations 5-7 5-8 5.11 Software licensing information 5.10 Maintenance considerations 5.5 LT card considerations 5-5 5.7 V-OLT and video coupler equipment considerations 5.12 Documentation Alcatel-Lucent 7360 ISAM FX R04.8 Installation considerations 5.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 5-5 5-8 5-8 5-8 5-1 .6 NT card considerations 5-5 5.4 Shelf considerations 5-4 5.2 Network considerations 5-2 5.5 — Planning the equipment 5.1 Overview 5-2 5. and the corresponding NT and LT cards • V-OLT.5 — Planning the equipment 5. ITSC. which includes the rack and shelves. Consider the following items when determining what you need: • • • • • • • • • 5.2 required number and type of shelves rack requirements shelf power and mounting accessories shelf hardware kits and shelf add-on kits installation-related items. This equipment implements the GPON protocol and adapts GPON PDUs to subscriber service interfaces. The 7360 ISAM FX is implemented in an access network topology that extends optical access across the last mile of the communications network to the subscriber using fiber optic cable to provide services from the network to residential or business subscribers.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide . which is located at the subscriber premises as distributed end-points of the access network. The 7360 ISAM FX access network consists of four distinct equipment types: • P-OLT. such as MTA. which is only required to support the V-OLT. consider the following requirements: • type of services that will be provided to subscribers • number of ONUs required for each type of subscriber: • estimated number of single-family subscribers • estimated number of multi-dwelling subscribers • estimated number of SOHO subscribers • estimated number of business subscribers with CES (DS1 or E1) requirements • number of LT ports per LT card type • number of NT ports per NT card type • number of LT cards per shelf type: 16. When planning the installation of the 7360 ISAM FX in an access network. • ONU. which distributes RF overlay video signals across the GPON if the network provider chooses this method for providing video services • WDM. and is used to mix and separate the RF video signals to and from the optical fiber going toward ONUs. or 4 5-2 May 2012 Alcatel-Lucent 7360 ISAM FX R04.1 Overview This chapter provides planning considerations for ordering the 7360 ISAM FX equipment. 8. such as power and alarm equipment expansion configuration requirements software licensing documentation other requirements. and BITS Network considerations This section describes the 7360 ISAM FX network equipment considerations including system planning. 04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 5-3 . 1 Modular ONTs — Estimate the number of subscribers. See the appropriate Litespan and Microspan user documentation for more information. Divide the total number of subscribers by 12 to determine the number of modular ONTs required. 3 Microspan MS-R and MS-C — Determine the required units based on CES requirements of subscribers. respectively. outdoor. 1 ONTs — Estimate the number of subscribers. or 7360 ISAM FX-4 shelves are required. 8. 7360 ISAM FX-8. 5 Racks — Divide the number of shelves by the number of shelves per rack to determine the number of racks required. 32 or 64 based on a 1:32 or 1:64 split) to determine how many LT ports are required. The number of SOHO outdoor ONTs or business ONTs equals the number of subscribers. 2 LT ports— Divide the number of modular ONTs by 8 to determine how many LT ports are required. 6 Racks — Divide the number of shelves by the number of shelves per rack to determine the number of racks required. 7360 ISAM FX-8. 4 LTs — Divide the number of LT ports required by the number of LT ports on the LT card to determine the total number of LT cards required.5 — Planning the equipment • rack and rack configurations • number of shelves per rack configuration • system capacity restrictions System planning for indoor. 4 Shelves — Divide the number of LT cards by 16. respectively. or 4 to determine how many 7360 ISAM FX-16. Each modular ONT can support 12 subscribers. Alcatel-Lucent 7360 ISAM FX R04. or 7360 ISAM FX-4 shelves are required. The number of indoor or outdoor ONTs equals the number of subscribers. One ONT is required for each subscriber. and business ONTs Use the following steps to calculate the system requirements to support the number of expected subscribers. 8. 2 LT ports— Divide the number of indoor or outdoor ONTs by the number of subscribers per LT port (for example. 3 LTs — Divide the number of LT ports required by the number of LT ports on the LT card to determine the total number of LT cards required. or 4 to determine how many 7360 ISAM FX-16. System planning for modular ONTs Use the following steps to calculate the system requirements to support the number of expected subscribers. 5 Shelves — Divide the number of LT cards by 16. The 7360 ISAM FX system typically supports 8 modular ONT units for each LT port. See section 6. rack Horizontal mounting — 4 7 Vertical mounting 2 — — Horizontal mounting — 4 7 19 in. and cables for the 7360 ISAM FX shelves.9 Cables Section 6. 8. EIA standard rack 5.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide .5 NT units and dummy front panels Section 6. Table 5-2 Ordering plug-in units and cables for the 7360 ISAM FX shelves Type of orderable item See section Plug-in units 5-4 GFCs Section 6.4 Fan units and fan filters Section 6.3 Rack considerations This section identifies the number of shelves that can be accommodated in a rack by rack size and rack mounting configuration.8 SFP and XFP modules Section 6.6 LT units and dummy front panels Section 6. Table 5-1 Number of shelves per rack Rack Rack mounting configuration 7360 ISAM FX-16 7360 ISAM FX-8 7360 ISAM FX-4 23 in. or 4) LT units for the required types of subscriber services dummy front panels required for any unused slots in the shelf existing and required spare plug-in units SFP and XFP modules required for network and expansion links required cables.4 Shelf considerations This section identifies the 7360 ISAM FX shelf equipment required including references to ordering information. see Table 5-1.5 — Planning the equipment 5. and where to find ordering information. such as power harnesses Table 5-2 lists the types of plug-in units including SFP and XFP modules. consider the number and type of: • • • • • • • NT units required LT slots that the shelf can accommodate (16.10 May 2012 Alcatel-Lucent 7360 ISAM FX R04.2 for more information about rack mounting configurations. For each shelf. Table 5-3 Number of LT ports per LT card LT card Number of LT ports NGLT-A 8 GPON ports NELT-B 36 GE or FE channels 18 GE or FE SFP channels 5. Alcatel-Lucent 7360 ISAM FX R04. 100Mbps. The V-OLT is supplied by third-party vendors. Table 5-4 Number of NT ports per NT card NT card Number of NT ports FANT-F 1 10Mbps. see Table 5-3. Contact your EDFA representative for information about your EDFA requirements.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 5-5 . V-OLT equipment The V-OLT equipment consists of EDFAs that can accept 1550 nm wavelength optical signals and split the signals into multiple optical feeds onto the fiber path. order both the V-OLT equipment and the video coupler equipment. or GE Base-T ports 4 10 GE SFP+ ports 1 ToD/1PPS RJ-45 connection port 1 10 MHz GPS SMA connection port 1 PPS SMA connection port 1 Local craft serial connection port 5.7 V-OLT and video coupler equipment considerations This section identifies the 7360 ISAM FX V-OLT and video coupler equipment. If the V-OLT function is required.5 LT card considerations This section identifies the number of LT ports per LT card. Order the appropriate EDFAs. see Table 5-4. ordering.6 NT card considerations This section identifies the number of NT ports per NT card. and installation considerations.5 — Planning the equipment 5. one per LT card two fiber management raceways.5 — Planning the equipment Video coupler equipment The video coupler equipment contains the following items: • • • • • • video coupler rack (standard 23 in. rack) three video coupler shelves. such as power and alarm equipment normally procured from commercial sources Contact your Alcatel-Lucent sales representative for more information. and to provide output from VCW2 to ONUs Ordering considerations Consider the following when ordering the video coupler equipment: • required cables and connection modules • installation-related items. • Optical fiber requirements Determine the optical fiber requirements for video lead from head-end equipment to the V-OLT. In particular. • Floor plan Determine the floor plan details: • • • • available space floor type overhead support management cable rack equipment • Subscribers Determine the number of subscribers who require the radio frequency (RF) video services delivered through the V-OLT. 5-6 May 2012 Alcatel-Lucent 7360 ISAM FX R04. APC-based or spliced connectors are used to avoid potential problems. splitters should be configured so that unused ports are terminated into APC-based connectors.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide . one on each side of the VCSLs optical jumper cables to connect LT cards and V-OLT to VCW2. LGX compatible (VCSL) one fiber storage shelf (optional) video coupler WDM cassettes (VCW2). The following is required: • number of connections • run lengths • connectors for termination Note — Alcatel-Lucent recommends that in the fiber distribution network. Installation considerations Consider the following when planning to install the WDM equipment in a CO location. such as lugs Alcatel-Lucent 7360 ISAM FX R04. width. If existing racks are to be used.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 5-7 . verify space availability.5 — Planning the equipment 5. access. The 7360 ISAM FX is typically installed in a CO environment. alarms. Collect information about the following: • number of connections • run lengths and required wire gauge • termination requirements.8 Installation considerations This section describes the 7360 ISAM FX equipment installation considerations for required space. Floor plan Collect the following floor plan information: • • • • measurements of the available space. Access The remote craft port to perform operations and maintenance is connected to the front on the GFC panel. The following subsections describe items to consider when planning the installation of the 7360 ISAM FX in the CO. and optical fiber. power and ground cable. and length floor type overhead support arrangement cable and rack requirement Alarms Determine the alarm termination requirements. Space Planners should determine the space requirement based on the number of shelves and racks required. floor plan. Power and ground cable Determine the power and ground cable requirements. and the number and types of connections required. Determine the total number of alarms. including height. 5.alcatel-lucent. splitters should be configured so that unused ports are terminated into APC-based connectors.5 — Planning the equipment Optical fiber Determine the optical fiber requirements.com/myaccess. The number of spares needed for each card type is determined by maintenance practices and equipment failure rates. Use the maximum power consumption figures to plan for power sizes required.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide . such as connector types Note — Alcatel-Lucent recommends that in the fiber distribution network. 5-8 May 2012 Alcatel-Lucent 7360 ISAM FX R04. APC-based or spliced connectors are used to avoid potential problems.11 Software licensing information Software licensing information is included when you purchase the software kits and licenses. 5. In particular. Order spare cards to support normal maintenance activities associated with the 7360 ISAM FX. If you are a new user and require access to this service.10 Maintenance considerations This section describes the 7360 ISAM FX maintenance considerations when ordering equipment. contact your Alcatel-Lucent sales representative.9 Power considerations See the 7360 ISAM FX Safety Manual for the maximum power consumption per unit. 5. Contact your Alcatel-Lucent sales representative for current part numbers for software kits and licenses.12 Documentation Customer documentation is available for download by registered customers from http://www. Collect information on the following: • number of connections • run lengths • termination requirements. 5. Generally. a minimum of one spare card of each type used is recommended for CO maintenance personnel. See Table 1 in the Preface for a list of the documents in the documentation set for the 7360 ISAM FX. 04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide 6-11 6-13 May 2012 6-1 .9 Optical modules 6.10 Cables Alcatel-Lucent 7360 ISAM FX R04.6 NT card and dummy front panel 6-9 6.5 Fan units and fan filters 6-8 6.3 Shelves 6.4 GFCs 6-3 6-6 6-7 6.1 Overview 6-2 6.7 NTIO card and dummy front panel 6-10 6.6 — Ordering the equipment 6.8 LT cards and dummy front panels 6-10 6.2 Racks and mounting parts 6. 04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide . 6-2 May 2012 Alcatel-Lucent 7360 ISAM FX R04. and identifies with a check mark the shelf to which an item or collection of items applies. Table 6-1 7360 ISAM FX equipment Type Item FX-16 Racks and mounting parts 7360 ISAM FX-16 mounting ✓ 7360 ISAM FX-8 mounting FX-8 ✓ 7360 ISAM FX-4 mounting Shelves NFXS-D ✓ ✓ NFXS-E ✓ NFXS-F GFCs ✓ NGFC-H ✓ NGFC-G Fan units and fan filters FX-4 ✓ AFAN-H ✓ AFAN-E ✓ AFAN-X ✓ NT card and dummy front panel FANT-F ✓ ✓ ✓ NT dummy front panel ✓ ✓ ✓ NTIO card and dummy front panel NTIO dummy front panel ✓ ✓ ✓ LT cards and dummy front panels NGLT-A ✓ ✓ ✓ NELT-B ✓ ✓ ✓ LT dummy front panel ✓ ✓ ✓ Fast Ethernet SFPs ✓ ✓ ✓ Gigabit Ethernet SFPs ✓ ✓ ✓ SFP+s ✓ ✓ ✓ E1 SFP ✓ ✓ ✓ Dual SFPs ✓ ✓ ✓ GPON SFPs ✓ ✓ ✓ XG-PON XFPs/SFPs (XFP/SFP+) ✓ ✓ ✓ Other ✓ ✓ ✓ Optical modules Note 1 — See the corresponding unit data sheet tor more information about a specific orderable item.6 — Ordering the equipment 6.1 Overview This chapter provides part number information about the 7360 ISAM FX equipment. Note 2 — The term dummy front panel is synonymous with the ANSI term filler plate. Table 6-1 lists the orderable items or collection of items. 75 in. I. EIA standard rack.) Horizontal mounting 23 in. rack (17. The 6-2 lists the supported rack mounting configurations by shelf type and rack size. For more information about the rack mounting configurations.6 — Ordering the equipment 6. Table 6-2 Rack mounting configurations Shelf Rack size Rack mounting configurations 7360 ISAM FX-16 23 in.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 6-3 . rack Horizontal mounting with brackets EIA standard 19 in. rack (17. rack. You can mount the 7360 ISAM FX-16 shelf in a 23 in.D. see 7360 ISAM FX Hardware Installation Manual. Table 6-3 Racks Rack Part number 23 in.2 Racks and mounting parts This section identifies the parts and part numbers for rack-mounted parts.D.rack Vertical mounting with baffles 7360 ISAM FX-8 EIA standard 19 in.) Horizontal mounting 23 in. Table 6-4 FEMA level rack mounting parts for 7360 ISAM FX-16 Type FEMA code (1) Part Part number Quantity 7360 ISAM FX-16 mounting (1 of 2) Alcatel-Lucent 7360 ISAM FX R04. or 19 in.75 in. and the 7360 ISAM FX-8 and 7360 ISAM FX-4 in a 23 in. rack. I. The required mounting parts listed are included in the shipment under one part number. rack 1AD 01412 0044 Table 6-4 lists the 7360 ISAM FX equipment orderable at the FEMA code level. rack Horizontal mounting with brackets 7360 ISAM FX-4 Table 6-3 identifies the part number for the 23 in. 7 mm) hex screws 1AD008180005 28 Fan with fan filter 3EC 37533 NB 2 7360 ISAM FX-16 . (12 mm) hex screws 1AD112490001 20 12 × 24 1/2in. (12. Table 6-5 identifies the orderable mounting parts required for 7360 ISAM FX-8 and 7360 ISAM FX-4.rack with one shelf 3FE 66742 AA 23 in. Table 6-5 Rack mounting parts for 7360 ISAM FX-8 and 7360 ISAM FX-4 Rack size Rack mounting configuration Part Part number Quantity 7360 ISAM FX-8 mounting (1 of 3) 6-4 May 2012 Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide . (12 mm) hex screws 1AD112490001 10 12 × 24 1/2in. rack 1AD 01412 0044 1 NFXS-D shelf 3FE 65209 BA 1 FX-16 left mounting bracket 3FE 54168 AA 1 FX-16 right mounting bracket 3FE 54168 AB 1 FX-16 fiber and heat baffle kit 3FE 67225 AA 1 12 × 24 1/2in.rack with two shelves 3FE 66742 AB (2 of 2) Note (1) See the 7360 ISAM FX Product Information Guide or the 7360 ISAM FX Hardware Installation Manual for FEMA level and other rack mounting configuration details. The rack mounting parts are ordered separately. rack 1AD 01412 0044 1 NFXS-D shelf 3FE 65209 BA 2 FX-16 left mounting bracket 3FE 54168 AA 2 FX-16 right mounting bracket 3FE 54168 AB 2 FX-16 fiber and heat baffle kit 3FE 67225 AA 2 12 × 24 1/2in.6 — Ordering the equipment Type FEMA code (1) Part Part number Quantity 7360 ISAM FX-16 .7 mm) hex screws 1AD008180005 14 Fan with fan filter 3EC 37533 NB 1 23 in. (12. 7 mm screws 1AD002300017 16 Fan unit 3FE 65060 AA 1 Fan filter 3FE 64928 BA 1 23 in. rack (17. rack (2 of 3) Alcatel-Lucent 7360 ISAM FX R04.7 mm screws 1AD002300017 16 Fan unit 3FE 65060 AA 1 Fan filter 3FE 64928 BA 1 NFXS-E 3FE 64936 BA 1 Horizontal shelf mounting kit 3FE 67300 AA 1 Left and right horizontal brackets 3FE 67313 AA 2 12-24 x 12. rack Horizontal mounting of the 7360 ISAM FX-8 in a 23 in.6 — Ordering the equipment Rack size Rack mounting configuration Part Part number Quantity 19 in. rack Horizontal mounting of the 7360 ISAM FX-8 in an EIA standard 19 in.D.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 6-5 . I.) NFXS-E 3FE 64936 BA 1 Horizontal shelf mounting kit (1) 3FE 67300 AA 1 12-24 x 12.75 in. rack. rack (17.3 Shelves This section lists the orderable variants of the 7360 ISAM FX shelf equipment.75 in.) Horizontal mounting of the 7360 ISAM FX-4 in a 23 in.D. rack Horizontal mounting of the 7360 ISAM FX-4 in an EIA standard 19 in.6 — Ordering the equipment Rack size Rack mounting configuration Part Part number Quantity NFXS-F 3FE 64991 BA 1 Horizontal shelf mounting kit (1) 3FE 67299 AA 2 12-24 x 12. I. 48 V only.7 mm screws 1AD002300017 10 Fan unit 3FE 64994 AA 1 Fan filter 3FE 64928 CA 1 7360 ISAM FX-4 mounting 19 in.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide .rack allows for two NT cards and one NTIO card to be mounted in the middle slots of the card cage allows for flexible LT card mounting. rack 23 in. Table 6-6 Orderable 7360 ISAM FX shelves Component Mnemonic Part number 7360 ISAM FX-16 shelf. meaning that several types of cards can be housed in the LT slots supports 48 V nominal power input voltage levels (± 20% tolerance) contains a field-replaceable fan unit and a field-replaceable fan filter has a built-in GFC (PDBP) supports 1+1 NT redundancy (1 of 2) 6-6 May 2012 Alcatel-Lucent 7360 ISAM FX R04.7 mm screws 1AD002300017 16 Fan unit 3FE 64994 AA 1 Fan filter 3FE 64928 CA 1 NFXS-F 3FE 64991 BA 1 Horizontal shelf mounting kit 3FE 67299 AA 2 Left and right horizontal brackets 3FE 67312 AA 2 12-24 x 12. excluding fan unit NFXS-D 3FE 65209 BA Includes required mounting brackets and screws Description NFXS-D: • • • • • • • mounts vertically in a 23 in. rack (3 of 3) Note (1) Only kit screws required for horizontal installation in 19 in. see Table 6-6. 6. see Table 6-7. meaning that several types of cards can be housed in the LT slots holds a field-replaceable GFC holds a field-replaceable fan unit and a field-replaceable fan filter supports 1+1 NT redundancy (2 of 2) 6. with mounting kit that includes required mounting brackets and screws provides housing for associated interface units allows for two NT cards and one NTIO card to be mounted in the lower slots of the card cage allows for flexible LT card mounting. 48 V only. as well as for the power-related alarms of the shelf. (Fan filter ordered separately) NFXS-F 3FE 64991 BA mounts horizontally in a 19 in. Note — The 7360 ISAM FX-16 shelf has a built-in GFC that is not field-replaceable. for user-defined alarms. including GFC and fan unit.6 — Ordering the equipment Component Mnemonic Part number 7360 ISAM FX-8 shelf. Order screws separately.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 6-7 . with mounting kit that includes required mounting brackets and screws provides housing for associated interface units. 48 V only. Table 6-7 Orderable GFCs Component Mnemonic Part number Description GFC for the 7360 ISAM FX-8 shelf NGFC-H 3FE 65675 AA NGFC-H is the power interface part of the 7360 ISAM FX-8 shelf and acts as the interface for inter-rack routing of alarms toward the NT card. (Fan filter ordered separately) NFXS-E 3FE 64936 BA Description NFXS-E: • • • • • • • • 7360 ISAM FX-4 shelf. kit not required.) allows for two NT cards and one NTIO card to be mounted in the lower slots of the card cage allows for flexible LT card mounting. x 8. including GFC and fan unit.94 in. (1 of 2) Alcatel-Lucent 7360 ISAM FX R04. mounts horizontally in a 23 in. EIA standard rack. rack.4 GFCs This section lists the orderable variants of the GFCs used in the 7360 ISAM FX shelves. mounts horizontally in a 23 in.86 in. kit not required. EIA standard rack. which are plug-in units of 405 x 225 mm (15. meaning that several types of cards can be housed in the LT slots holds a field-replaceable GFC holds a field-replaceable fan unit and a field-replaceable fan filter supports 1+1 NT redundancy NFXS-F: • • • • • • • • mounts horizontally in a 19 in. Order screws separately. rack. AFAN-E provides forced air cooling in a 7360 ISAM FX-8 shelf. for user-defined alarms. which generates a common fan alarm toward the NT cards (via the NGFC-E) in case of fan failure and lights the fan alarm LED. This fan filter must be removed when the shelf is used in closed (cabinet-like) environments where such a filter is not applicable and where higher ambient temperatures (higher than 45°C) are expected. 48 V. only for the 7360 ISAM FX-16 shelf AFAN-H For fixed speed: 3EC 37533 NB Description (1) AFAN-H provides forced air cooling in a 7360 ISAM FX-16 shelf. variable speed fans mounts in the 7360 ISAM FX-8 shelf fan area behind the fan unit cover supports nominal voltages: −48 V dc / −60 V dc contains a fan unit control card. see Table 6-8. secured to the 7360 ISAM FX-8 shelf with a screw field-replaceable and can be hot-inserted provides the space and guiding for a field-replaceable fan filter if the fan unit is equipped with fan filter.5 Fan units and fan filters This section describes the orderable variants of the fan units and fan filters for the 7360 ISAM FX shelves.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide . and has the following features: • • • • • • Fan for the 7360 ISAM FX-8 shelf (Fan filter ordered separately) AFAN-E 3FE 65060 AA contains eight fixed-speed fans supports nominal voltages: −48 V dc secured to the shelf by screws field-replaceable and can be hot-inserted connected to the shelf backplane via two 15-pin male D-SUB miniature connectors. (2 of 2) 6. and has the following features: • • • • • • • • contains six wide-voltage range. temperature controlled. equipped with fan filter for use in CO environment.6 — Ordering the equipment Component Mnemonic Part number Description GFC for the 7360 ISAM FX-4 shelf NGFC-G 3FE 65676 AA NGFC-G is the power interface part of the 7360 ISAM FX-4 shelf and acts as the interface for inter-rack routing of alarms toward the NT card. Note — When installed in a shelf. Table 6-8 Orderable fan units and filters Component Mnemonic Part number Fan with fan filter. a fan filter should be changed at least every 3 months depending on conditions. the fan unit is only suitable for a CO environment (1 of 2) 6-8 May 2012 Alcatel-Lucent 7360 ISAM FX R04. as well as for the power-related alarms of the shelf. and 7360 ISAM FX-4.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 6-9 . The same dummy front panel can be used for all FX shelves including 7360 ISAM FX-16. which generates a common fan alarm toward the NT cards (by way of the NGFC-F) in case of fan failure and lights the fan alarm LED secured to the 7360 ISAM FX-4 shelf with a screw field-replaceable and can be hot-inserted provides the space and guiding for a field-replaceable fan filter if the fan unit is equipped with fan filter. 6. without SFPs (ANSI variant) FANT-F 3FE 53701 BD FANT-F card provides optical and electrical connections for Ethernet or Gigabit Ethernet network connectivity to a high-bandwidth IP services network NT dummy front panel — 3FE 65651 AA Dummy front panel for the NT card must be used when the second NT card is not used in the shelf. see Table 6-9. the fan unit is only suitable for a CO environment (2 of 2) Note (1) The variable speed fan costs more. temperature controlled. Table 6-9 Orderable NT card and NT dummy front panel Component Mnemonic Part number Description 480 Gb/s NT with ANSI T1 BITS. 7360 ISAM FX-8.6 NT card and dummy front panel This section describes the orderable variant of the NT card and dummy front panel for the NT unit for the 7360 ISAM FX shelves. and IEEE1588 for high-density/high-bandwidth applications. SyncE. variable speed fans mounts in the 7360 ISAM FX-4 shelf fan area behind the fan unit cover supports nominal voltages:−48 V dc / −60 V dc contains a fan unit control card. but is less noisy at room temperature than the fixed speed fan.6 — Ordering the equipment Component Mnemonic Part number Description Fan for the 7360 ISAM FX-4 shelf (Fan filter ordered separately) AFAN-X 3FE 64994 AA AFAN-X provides forced air cooling in a 7360 ISAM FX-4 shelf. and has the following features: • • • • • • • • Fan filter for the 7360 ISAM FX-8 — 3FE 64928 BA/DA — Fan filter for the 7360 ISAM FX-4 — 3FE 64928 CA/EA — contains four wide voltage range. Alcatel-Lucent 7360 ISAM FX R04. 7360 ISAM FX-8.7 NTIO card and dummy front panel This section describes the orderable variant of the NTIO card and the NTIO dummy front panel for the 7360 ISAM FX shelves. A dummy front panel must be installed in the NTIO slot on the shelf. P2P GE/FE LT card (36 lines).244 Gb/s upstream). 8-port GPON LT card with enhanced (downstream) traffic management capabilities NGLT-C 3FE 67301 AA NGLT-C is a GPON LT card that can be installed in a 7360 ISAM FX shelf. SFP GPON optical modules can be plugged into the NGLT-C card. SFP GPON optical modules can be plugged into the NGLT-A card.488 Gb/s downstream and 1.488 Gb/s downstream and 1. LT dummy front panel — 3FE 65005 AA An LT dummy front panel must be installed in any unused LT slot.8 LT cards and dummy front panels This section describes the orderable variants of the LT cards and LT dummy front panels for the 7360 ISAM FX shelves.488 Gb/s downstream and 1. and 7360 ISAM FX-4 6. see Table 6-10. Table 6-11 Orderable LT cards and LT dummy front panels Component Mnemonic Part number Description 8-port GPON LT card with enhanced (downstream) traffic management capabilities NGLT-A 3FE 64279 AA NGLT-A is a GPON LT card that can be installed in a 7360 ISAM FX shelf. see Table 6-11. Table 6-10 Orderable NTIO dummy front panel Component Mnemonic Part number Description NTIO card — — — NTIO dummy front panel — 3FE 65651 BA The same NTIO dummy front panel can be used for all FX shelves including 7360 ISAM FX-16. The NGLT-C provides termination of eight GPON ports (2. 6-10 May 2012 Alcatel-Lucent 7360 ISAM FX R04. excluding SFPs NELT-B 3FE 62543 AA NELT-B is an FE/GE LT card that has up to 36 FE/GE optical ports for Ethernet access. The NGLT-A provides termination of eight GPON ports (2.244 Gb/s upstream).04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide . The FGLT-A provides termination of sixteen GPON ports (2. Note — The 7360 ISAM FX shelves do not use the NTIO card. SFP GPON optical modules can be plugged into the FGLT-A card. 16-port GPON LT card with enhanced (downstream) traffic management capabilities FGLT-A 3FE 66721 AA FGLT-A is an GPON LT card that can be installed in a 7360 ISAM FX shelf.6 — Ordering the equipment 6.244 Gb/s upstream). 6 — Ordering the equipment 6.9 Optical modules This section lists the orderable variants of the Alcatel-Lucent approved SFP and XFP modules. Table 6-12 identifies with a check mark the card to which an optical module applies.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 6-11 . Table 6-12 Orderable optical modules Item Part number FANT-F NELT-B NGLT-A NGLT-C FGLT-A Fast Ethernet SFPs FE-FX 3FE 25777 AA ✓ FE-LX10 3FE 25778 AA ✓ FE BX10-D 3FE 29194 AA ✓ 100Base-T 3FE 63343 AA ✓ Copper SFPs 1000Base-T 3FE 28784 AA ✓ 1000Base-T 3FE 64297 AA ✓ Gigabit Ethernet SFPs GE-SX 3FE 25773 AA GE-LX 3FE 25774 AA ✓ GE-EX 3FE 25775 AA ✓ GE-ZX 3FE 25776 AA ✓ GE-YX CWDM (24 dB) 3FE 25771 AA ✓ 3FE 25771 AB ✓ 3FE 25771 AC ✓ 3FE 25771 AD ✓ 3FE 25771 AE ✓ 3FE 25771 AF ✓ 3FE 25771 AG ✓ 3FE 25771 AH ✓ 3FE 2571 CA ✓ 3FE 29549 CA ✓ 3FE 29550 CA ✓ 3FE 29551 CA ✓ 3FE 29552 CA ✓ 3FE 29553 CA ✓ 3FE 29554 CA ✓ 3FE 29555 CA ✓ 3FE 25772 AA ✓ GE-VX CWDM (32 dB) GE-BX10-U ✓ ✓ (1 of 2) Alcatel-Lucent 7360 ISAM FX R04. 04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide .6 — Ordering the equipment Item Part number FANT-F NELT-B GE-BX10-D 3FE 25772 AB ✓ ✓ 1000Base-T 3FE 28784 AA ✓ ✓ GE-BX40-U 3FE 28785 AA ✓ GE-BX40-D 3FE 28785 AB ✓ NGLT-A NGLT-C FGLT-A SFP+s 10 GE-R 3FE 62600 AA 10 GE-R 3FE 62600 CA 10 GE-R 3FE 62600 DA ✓ 10 GE-R 3FE 62600 EA ✓ 10 GE-R 3FE 65608 AA ✓ 10 GE-R 3FE 63264 AA ✓ 10 GE-R 3FE 65831 AA ✓ 10 GE-R 3FE 65832 AA E1 SFP 2 × E1 SFP 3FE 67231 AA ✓ Dual SFPs GE-BX10-D 3FE 65106 AA ✓ GE-BX10-D 3FE 65106 DA ✓ FE-BX10-D 3FE 65107 AA ✓ FE-BX10-D 3FE 65107 DA FE-BX10-D ✓ 3FE 66131 AA (1) ✓ 3FE 66131 DA (1) ✓ GE-BX10-D FE-BX10-D GE-BX10-D GPON SFPs GPON SFP B+ 3FE 53441 AA ✓ GPON SFP B+ 3FE 53441 AC ✓ ✓ ✓ GPON SFP C+ 3FE 53441 BA ✓ ✓ ✓ GPON SFP B+ with OTDR 3FE 53441 CC ✓ ✓ ✓ GPON SFP C+ with OTDR 3FE 53441 DA ✓ ✓ ✓ XG-PON XFPs/SFPs XG-PON1 OLT XFP 3FE 53971 AA XG-PON1 ONU SFP+ 3FE 53972 AA Other TM1 SFP 3FE 66247 AA ✓ (2 of 2) 6-12 May 2012 Alcatel-Lucent 7360 ISAM FX R04. 10 Cables This section describes the orderable cables required for the 7360 ISAM FX equipment installation. Thomas and Betts 54855BEPH or equivalent • 2 AWG 1/4 . See Burndy catalog for additional tool options. • Input power lug: 2 AWG.5/8 dual-hole copper lug long barrel peep. Alcatel-Lucent 7360 ISAM FX R04.6 — Ordering the equipment Note (1) This is a dual-rate compact SFP. angled head 3EM 22996 AX 7360 ISAM FX-8 7360 ISAM FX-4 ✓ ✓ Note (1) See your Alcatel-Lucent representative for the supported cable variant for 7360 ISAM FX-16. Lugs and lug tool Alcatel-Lucent recommends the following crimp lugs and crimp lug tool: • Input power lug: 2 AWG.5/8 dual-hole copper lug long barrel peep.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 6-13 . Burndy YAZ2C-2TC14 or equivalent • 2 AWG 1/4 . Table 6-13 Orderable CO external alarm cables Item Part number 7360 ISAM FX-16 50-pin micro DSUB connector (1) 3EM 22996 XX ✓ 50-pin micro DSUB connector. See Thomas and Betts catalog for additional tool options. 90C. 90C. CO external alarm cables Table 6-13 describes the CO external alarm cables that are orderable showing cable support per shelf type using a checkmark. See your Alcatel-Lucent sales representative for details about the required cables. 6. uses Thomas and Betts Die Code 33. uses Burndy Die Code 10. 6 — Ordering the equipment 6-14 May 2012 Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide . 04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 A-2 A-1 .A. Mnemonics A.1 Mnemonics overview Alcatel-Lucent 7360 ISAM FX R04. A. Mnemonics A.1 Mnemonics overview Table A-1 describes the 7360 ISAM FX equipment mnemonics. Table A-1 Equipment mnemonics A-2 Mnemonic Description AFAN-H 7360 ISAM FX-16 fan unit - version H AFAN-E 7360 ISAM FX-8 fan unit - version E AFAN-X 7360 ISAM FX-4 fan unit - version X FANT-F 7360 ISAM FX NT card - version F FGLT-A 7360 ISAM FX GPON LT card - version A NELT-B 7360 ISAM FX 36-line FE/GE LT card - version B NGLT-A 7360 ISAM FX GPON LT card - version A NGLT-C 7360 ISAM FX GPON LT card - version C NFXS-D 7360 ISAM FX-16 shelf - version D NFXS-E 7360 ISAM FX-8 shelf - version E NFXS-F 7360 ISAM FX-4 shelf - version F NGFC-G 7360 ISAM FX GFC - version G NGFC-H 7360 ISAM FX GFC - version H May 2012 Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide Glossary 7360 ISAM FX 7360 Intelligent Services Access Manager FX A DSLAM that operates in a packet aggregation network. The 7360 ISAM FX enables deployment of triple-play services, such as video on demand, high-definition TV, and broadcast TV services for all subscribers simultaneously. AFAN-E 7360 ISAM FX-8 fan unit Fan unit for the 8-slot shelf AFAN-H 7360 ISAM FX-16 fan unit Fan unit for the 16-slot shelf AFAN-X 7360 ISAM FX-4 fan unit Fan unit for the 4-slot shelf AMS Access Management System ANSI American National Standards Institute A nonprofit, nongovernmental body supported by over 1000 trade organizations, professional societies, and companies; ANSI was established for the creation of voluntary industry standards. ATM Asynchronous Transfer Mode AWG American Wire Gauge BITS Building Integrated Timing Source A clock that supplies a composite clock timing reference to all other clocks in a building over BITS clock cables Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 GL-1 Glossary BPA Backplane Assembly BRAS Broadband Remote Access Server CAT 5e Category 5 Ethernet CB Circuit Breaker CBN Common Bonding Network CC Cross-Connect CDRH Center for Devices and Radiological Health CEC Canadian Electrical Code CEV Controlled Environmental Vault A temperature- and humidity-controlled underground vault that houses components at a remote location CFR Code of Federal Regulation (U.S.) CLEI Common Language Equipment Identification A 10-character code used to identify telecommunications equipment. The 10-character structure, outlined in the Telcordia specification, specifies the basic product type, features, source document, and associated drawings and versions. A CLEI code is unique to a specific piece of equipment. CLI Command Line Interface CO Central Office CPE Customer Premises Equipment CSA Canadian Standards Association CT Craft Terminal DSLAM Digital Subscriber Line Access Multiplexer EDG Energy Dumping Ground EIA Electronics Industries Association EMAN Ethernet Metropolitan Area Network EMC Electromagnetic Compatibility EMC designates the ability of commodities to function normally in the electromagnetic environment (this ability is termed Electromagnetic Susceptibility [EMS]), and the ability not to generate unbearable electromagnetic interference to other devices and equipment in the same environment (this ability is termed Electromagnetic Interference [EMI]). These two abilities are collectively named EMC. EMS GL-2 Element Management System May 2012 Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide S. IWF Interworking Function IWF provides seamless packet transmission between two protocol stacks. FANT-F Combined NT unit version F FCC Federal Communications Commission (U. such as video on demand. ESD Electrostatic Discharge ESD is the rapid discharge of static electricity from one electrically-charged conductor to another of a different potential. For example.Glossary EMS manages the components of a network.984 series of standards. The ISAM enables deployment of triple-play services. IBN Isolated Bonding Network ICES Interference-Causing Equipment Standard (Industry Canada) IEC International Electrotechnical Commission IHub Intelligent Hub IPTV Internet Protocol Video/Television ISAM Intelligent Services Access Manager The Intelligent Services Access Manager is an xDSL access multiplexer that operates in a packet aggregation network. IWF can connect an ATM endpoint with a frame relay endpoint using mappings between the two protocol stacks.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 GL-3 . high-definition TV. LAN Local Area Network LIM Line Interface Module A network terminator for CEPT and T1. LNWW Large New Equipment Practise Worldwide Alcatel-Lucent 7360 ISAM FX R04. An electrostatic discharge can damage integrated circuits found in computer and communications equipment.) FDA Food and Drug Administration FE Fast Ethernet GE Gigabit Ethernet Ethernet interface that runs at 1000 Mb/s GFC General Facilities Card GPON Gigabit Passive Optical Network GPON is a high performance PON technology based on the G. and broadcast TV services for all subscribers simultaneously. Glossary LP A slot in the NE shelf where an applique is installed LSM Line Server Module A more generic term than LIM since it denotes both xDSL line interface modules and any other server application specific module. and Maintenance OLT Optical Line Termination ONT Optical Network Terminal ONU Optical Network Unit GL-4 May 2012 Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide . LT Line Termination Equipment that terminates the access line at the network end NE Network Element NEBS Network Equipment Building Standards NEC U. Administration.S. National Electrical Code NELT-B Ethernet line termination (LT) unit version B NFXS-D 7360 ISAM FX 16-slot shelf NFXS-E 7360 ISAM FX 8-slot shelf NFXS-F 7360 ISAM FX 4-slot shelf NGFC-G 7360 ISAM FX-4 power unit The power unit of the 4-slot shelf NGFC-H 7360 ISAM FX-8 power unit The power unit of the 8-slot shelf NGLT-A GPON line termination (LT) board with Traffic Manager version A NSP Network Service Provider NT Network Termination NTA Network Termination A NTB Network Termination B NTIO Network Termination Input/Output NTR Network Timing Reference OAM Operation. ONUs provide services to a single family home. converter. and offer high speed and physical compactness. and video services and terminates the ISAM network at a subscriber location. RAL Restricted Access Location RB Residential-Bridge RF Radio Frequency RFI Radio Frequency Interference Rx Receive SDH Synchronous Digital Hierarchy SELV Safety Extra Low Voltage A circuit that has no direct connection to a primary power source. its voltages do not exceed a safe value. IPTV. The devices are designed for use with small form-factor connectors. SFP Small Form-factor Pluggable SFP is a specification for a new generation of optical modular transceivers.Glossary Equipment that provides voice. and RF video.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 GL-5 . The devices are hot-swappable. or equivalent isolation device. a business location. but derives its power from either a transformer. or from a battery. Services can include POTS. The circuit is designed and protected so that under normal and single fault conditions. data. or a multi-dwelling residence. OSP Outside Plan PBA Printed Board Assembly PDBP-C 7360 ISAM FX-16 power unit The power unit of the 7360 ISAM FX 16-slot shelf P-OLT Packet Optical Line Termination PON Passive Optical Network A fiber-based network that uses passive splitters to deliver signals to multiple users POTS Plain Old Telephone Service PVC Permanent Virtual Circuit A PVC is an ATM end-to-end logical connection between two user/network interfaces. such as an apartment complex or condominium. high-speed Ethernet. SNMP Simple Network Management Protocol SNMP is a standard protocol for the management of entities in an IP local area network. SONET Synchronous Optical Network Alcatel-Lucent 7360 ISAM FX R04. A PVC may pass through several ATM switching NEs. ToD Time of Day Tx Transmit UL Underwriters Laboratories. but they appear to be on the same LAN in VPLS. Inc. The services can be from different locations. VLAN Virtual Local Area Network VPLS Virtual Private LAN Service A type of VPN in which a number of sites are connected in a single bridged domain over an IP network. or 1550 nm. 1310 nm. VRF Virtual Routing Forwarder A logical or virtual routing function with associated routing table that can be instantiated in a router capable of supporting IP VPN services XFP 10-GE small form-factor pluggable An XFP module is a hot-swappable. XFP was developed by the XFP Multi Source Agreement Group. 10 gigabit Ethernet and other applications.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide . for 10 Gb/s SONET/SDH. even though it uses the resources of a public switched network. GL-6 May 2012 Alcatel-Lucent 7360 ISAM FX R04. typically operating at 850 nm. VPN Virtual Private Network VPRN Virtual Private Routed Network A network exhibiting at least some of the characteristics of a private network. gigabit Ethernet. fiber channel.Glossary SW Control Software SW is an acronym used for IHub control software SyncE Synchronous Ethernet TL1 Transaction Language 1 TNV Telecommunications Network Voltage TNV is a secondary circuit for telecommunications networks. protocol-independent transceiver. TNV complies with IEC 950. 1-22 documentation ordering. 2-8 NT. 6-2 rack mounting configurations. 2-8 capabilities IWF. 6-8 feature descriptions new features. 4-2 CLEI codes. 2-8 B equipment management. 5-8 dummy front panels. 2-7 C F fan filters ordering. 2-4 shelf types. 1-17 cards dimensioning. 1-2 ordering. 6-9 NT cards. 1-17 GPON. 6-10 LT cards. 1-24 Alcatel-Lucent 7360 ISAM FX R04. 3-2 shelf configurations. 1-6 fiber management baffles. 2-7 filler plates LT. 4-2 SFP. 2-2 supported plug-in units. 2-7 dimensioning cards.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide E May 2012 IN-1 . 1-16 baffles heat and fiber management.Index Numbers D 7360 ISAM FX network topology. 1-17 characteristics optical modules. 5-2 ordering plug-in units. 6-8 fan units ordering. 3-8 FX-8 rack mounting configurations. 1-22 H heat management baffles. 1-14 mounting kits shelf installation. 1-14 network side network topology. 5-8 fan filters. 5-3 optical modules approved. 6-7 LT cards. 5-8 V-OLT equipment. 6-11 May 2012 Alcatel-Lucent 7360 ISAM FX R04. 6-10 NT filler plate. 2-8 filler plates. 2-8 filler plates. 5-2 documentation. 1-3 new features feature descriptions. 6-11 software. 1-5 network termination units. 1-5 subscriber side. 2-6 IWF capabilities. 1-14 installation mounting kits. 6-9 NT filler plate ordering. 6-10 M management equipment. 4-2 ordering. 1-7 FX-16 rack mounting configurations. 2-8 ordering. 1-6 NT cards dummy panels. 3-5 G general facilities cards. 1-17 L LT cards dummy panels. 6-9 GFC.Index functional decomposition — ordering functional decomposition system architecture. 2-7 I IHub system architecture. 4-2 characteristics. 6-8 filler plate LT. 5-5 XFP modules. 6-9 O ONTs system planning for indoor ONTs. See NT cards network topology 7360 ISAM FX. 6-8 fan units. 6-2 SFP modules. 1-2 network side. 3-3 FX-4 rack mounting configurations.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide . See GFC GFC ordering. 5-3 system planning for modular ONTs. 6-10 LT filler plate. 2-6 IN-2 N Network management. 6-7 GPON dimensioning. 6-10 NT. 1-16 network. 6-9 plug-in units. 5-3 system planning for outdoor ONTs. 2-8 ordering. 6-9 NT unit. 3-8 FX-8.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide May 2012 IN-3 . 6-11 physical decomposition system architecture. 5-3 P-OLT connection capacity specifications. 1-14 physical decomposition. 6-10 NT. 6-11 shelf configurations. 1-3 Alcatel-Lucent 7360 ISAM FX R04. 5-3 for outdoor ONTs. 6-11 R rack equipment. 6-9 NT unit. 2-4 shelf types. 1-23 part numbers documentation.Index P — XFP module P system architecture functional decomposition. 4-2 SFP module ordering. 2-2 software ordering. 3-2 rack mounting configurations. 5-8 subscriber side network topology. 5-8 fan filters. 3-5 redundancy support 1+1 NT. 3-3 FX-4. 5-3 for modular ONTs. 6-8 filler plate LT. 6-9 GFC. 5-8 XFP modules. 1-7 system planning for indoor ONTs. 6-11 software. 1-23 V V-OLT equipment ordering. 6-7 LT cards. 2-7 T technical specifications P-OLT connection capacity. 1-7 IHub. 6-10 LT filler plate. 1-23 S SFP characteristics. 6-10 NT filler plate. 3-2 FX-16. 6-9 SFP modules. 1-7 plug-in units. 5-5 X XFP module ordering. 6-8 fan units. Index IN-4 May 2012 Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide . com/myaccess Product manuals and documentation updates are available at alcatel-lucent. If you are a new user and require access to this service.alcatel-lucent.com Documentation feedback [email protected] documentation and product support Customer documentation http://www.com .alcatel-lucent.com. please contact your Alcatel-Lucent sales representative. Technical Support http://support. All rights reserved.© 2012 Alcatel-Lucent. 3FE 54967 AAAA TCZZA Edition 01 .
Copyright © 2024 DOKUMEN.SITE Inc.