38048190 Basic Config Guide for OCLAN Switch Ver 3 0



Comments



Description

Broadband Multiplay ProjectBasic Configuration Guide for OCLAN Switch v 3.0 HCL Infosystems Ltd. This document contains proprietary information of HCL Infosystems Ltd. No part of this document may be re-produced, stored, copied, or transmitted in any form or by means electronic, mechanical, photocopying or otherwise, without the express consent of HCL Infosystems Ltd. These services are provided by HCL Infosystems Limited – System Support Organisation – InfoStructure Services under the controls established by a quality management system that meets the requirements of ISO 9001:2000 which has been independently certified by BVQI under certificate number: 131026 Interfaces Available: Console Interface and 10/100 base TX Ethernet Interface. It performs the function of master/slave switchover. implementing the functions of control module and switching module.Basic Configuration Guide for OCLAN Switch v3. Gigabit Ethernet Interface board and 10giga bit Ethernet board.0 Page 2 of 11 OCLAN SWITCH Unit/Component introduction SWITCH : ZXR10 T64G OEM : ZTE Corporation Control Switching Board The Control Switching Board (MCS) is the core of ZXR10 T64G. CONFIDENTIAL .10 GB Ethernet is not being used in BSNL currently. Line Interface Cards The Line Interface cards include Fast Ethernet Interface board. Line Interface Cards Used  2 * 44FE + 4GE Interface card  1 * 24 GE Interface Card Ports Used in BSNL currently  GE Interfaces populated with SFPs : 17 nos  FE Interfaces populated with SFPs : 16 nos ROLE OF OCLAN SWITCH CONFIDENTIAL .Basic Configuration Guide for OCLAN Switch v3.0  44 FE + 4 GE Interface Board Page 3 of 11 44FE + 4GE Interface card board provides 44 Fast Ethernet Optical Interfaces and 4 gigabit Ethernet electrical Interfaces.  24 port Gigabit Ethernet Interface Board This provides 4 gigabit Ethernet Electrical Interfaces and 20 Ethernet Optical Interfaces. OCLAN switches aggregate the number of DSLAMs in every OC cities as required in the project. Power cable and Lugs for OCLAN is shipped along with the equipment and connect it accordingly and on PDP side crimp the –ve with point type lug and other two ( +ve and ground ) with round type. CONFIDENTIAL .0 Page 4 of 11 OCLAN Switches which becomes the Tier 2 component of the network resides in the Access layer. Rack Layout Note: 1. Power Cabling: 1. 2. Between PDP and OCLAN Rack there should be 2U gap.Basic Configuration Guide for OCLAN Switch v3. PDP should be fixed at the front side of Rack and should be at the TOP. 11. 3. 5. 10. 40 and 41  Port 40 to be configured for Uplink. 9. slot 1 and slot 2 populated with 44 FE + 4 GE card will be inserted with the following SFP modules. 7. SFP MODULE INSERTION RULE  As described in the above figure. 6.Basic Configuration Guide for OCLAN Switch v3. 4.  Port 41 is reserved for Uplink  All other ports mentioned above to be configured for connecting DSLAMs  Slot 5 populated with 24 GE card will be inserted with the following SFP modules. 12 and 13 CONFIDENTIAL . 2.  4 GE SFPs in port numbered 45. 47 and 48  8 FE SFPs in port numbered 1.0 CONTROL AND LINE INTERFACE CARD INSERTION RULE Page 5 of 11 Note: Each Slot in the slot numbered from 1 to 6 from top of the switch has to be populated with appropriate cards as shown in the figure above. 6.  9 GE SFPs in port numbered 5. 46. 8. CONFIDENTIAL . use attenuators of appropriate dB so as to attain Optical Power within the given range.41 45 to 48 5 24GE 5 to 13 Optical Power Range for Transceivers in OCLAN Switch Tx Optical Power Range in dBm Min GE SFP FE SFP SMF MMF -5 -9. For FE Transceivers.Basic Configuration Guide for OCLAN Switch v3. preferably towards the Rx Minimum value.5 Max 2 -3 Rx Optical Power Range in dBm Min -22 -17 Max -3 0 Transceiver Type Fiber Type Note: Use 0 dB attenuators for GE Transceivers.41 45 to 48 1 to 6 2 44 FE + 4 GE 40.0 Fiber Cabling Details Page 6 of 11 Slot no Card Type Port no 1 to 6 SFP/XFP Type FE SFP FE SFP GE SFP FE SFP FE SFP GE SFP GE SFP Fiber Cable Type LC-FC Multimode LC-FC Multimode LC-FC Singlemode LC-FC Multimode LC-FC Multimode LC-FC Singlemode LC-FC Singlemode Connecting to DSLAM via BSNL provided Converters T1 via UT Starcom supplied STM Converter DSLAMs DSLAM via BSNL provided Converters T1 via UT Starcom supplied STM Converter DSLAMs DSLAMs 1 44 FE + 4 GE 40. 0 Page 7 of 11 Connecting to ZXR10 T64G Via Console port: Connect the PC’s serial port and OCLAN switch’s Console port in the Control Switching module. Goto All Programs Accessories Communications HyperTerminal And set the following parameters as shown after selecting the appropriate COM port. Note: Before Powering on. connect the Console and capture all the logs.Basic Configuration Guide for OCLAN Switch v3. Bits per sec : 115200 Data bit :8 Parity : none Stop bit :1 Flow control : none CONFIDENTIAL . . Input “enable” command to enter the privilege mode.  Prompt : ZXR10(config)#  You are able to implement system configuration in Global (Terminal) Mode SUMMARY User mode Privilege mode Global mode ZXR100> ZXR100# ZXR100(config)# CONFIDENTIAL . Password to enter privilege mode: zxr10  Prompt : ZXR10#  The system parameters can be displayed and configured in Privilege (Enable) Mode  Relevant Commands  show running-config  show ip route  show interface Input “configure terminal” command to enter the privilege mode. Then power ON the system. you may  View simple info  Use ping command etc.0 After successful connection establishment capture the logs: Go to Transfer Capture text In this specify the folder to which the file is to be stored.Basic Configuration Guide for OCLAN Switch v3. After capturing the first boot log you will be getting a prompt as follows Page 8 of 11  You will enter to the user mode now directly after successfully log into system  Prompt : ZXR10>  In the User Mode. where AAA denotes the location code as per NIB Naming Scheme BBB denotes the Device Type i. For Ex : OCLAN Switch in Bangalore to be configured as BGL-LSW-OCT2-01 CONFIDENTIAL .  Setting TIME for the System To set the system time use the command “clock set” in the enable mode (privilege mode) as given below ZXR100#clock set <hh:mm:ss>  Setting NAME for the System To set the system name use the command “hostname” in global configuration mode. AAA-BBB-ccccc-<ID>. ZXR100 (Config)#Username <name> password <password> Username : bbmp Password : bbmp123  Configure ip address of management port .1 Now OCLAN Switch is ready for access via telnet.1.02 . ZXR100(Config)# nvram mng-ip-address <ip address> IP address: 192.e. ID denotes integer ID ex: 01.0 Page 9 of 11 CONFIGURATION TASKS  Set a username and password for Telnet Access.168. ZXR100(config)#hostname <system name> System name to be given as per standard naming conventions as follows. LSW Ccccc (3-5 characters will be used) denotes the function type here it is OCLAN.OCT2.Basic Configuration Guide for OCLAN Switch v3. Bangalore PORT CONFIGURATION FOR REDUNDANT UPLINK Slot 2 : Port no: 40 Follow the configuration steps as above Only changes to be made on port number as fei_2/40.0 PORT CONFIGURATION FOR UPLINK Slot 1: Port no: 40 1) Login to the system using proper credentials 2) Input enable command in the user mode ZXR100>enable 3) Input configure terminal command in the privilege mode ZXR100#configure terminal 4) Create VLAN using following commands ZXR100#vlan database ZXR100(vlan)#vlan <vlan-id> [name <vlan-name>] 5) Assigning IP address to the Uplink Port ZXR10#configure terminal ZXR10(config)#interface vlan <vlan-id> ZXR10(config-if)#ip address <ip-address> <netmask> IP address and mask to be intimated later from NOC. CONFIDENTIAL . Bangalore 6) Port Configuration. ZXR100(config)# interface fei_1/40 ZXR100(config-if)#no shutdown ZXR100(config-if)#negotiation auto ZXR100(config-if)#switch port mode hybrid Page 10 of 11 ZXR100(config-if)#switchport hybrid vlan <vlan-id> untag Vlan-id to be intimated later from NOC.Basic Configuration Guide for OCLAN Switch v3. Corresponding vlanid and IP address change will be intimated as and when required. Note: Primary GE link from OCLAN to DSLAM will be connected to SFP GE ports available in the slot 5 of OCLAN. assigning of ip addresses etc.Basic Configuration Guide for OCLAN Switch v3. primary link will be from slot 1(port 1 to 6) and redundant link from slot 2(port 1 to 6). Assigning of vlan-ids to the particular port. Redundant GE link from OCLAN to DSLAM will be connected to SFP GE ports available in slot 1 or slot 2(port 45 to 48 in both slot 1&2). CONFIDENTIAL . If the link to DSLAM is FE.0 FOR CONNECTION TO DSLAMS Page 11 of 11 Configure the respective ports using the above procedures for vlan-id creation.
Copyright © 2024 DOKUMEN.SITE Inc.