R410AVRF inverter multi-system Air-Conditioners 60Hz 13KX03E R410A History of Technologies more efficient , more sophisticated KX2 2 KX4 KX6 (8~12HP) Line Up Contents Introduction 4~17 Outdoor units 18~33 Indoor units 34~63 Control systems 64~71 Corrosion Protection Treatment series 72 . 73 High Head series 74~77 Further information 78~81 3 R410A Product Line Up <Outdoor units> from 11.2kW up to 136.0kW(24models) Single use (1 Outdoor unit) Capacity Model Index : kW BTU / h kcal / h 4HP 11.2 38,200 9,630 5HP 14.0 47,800 12,040 6HP 15.5 52,900 13,330 8HP 22.4 76,400 19,260 10HP 12HP 14HP 16HP 18HP 20HP 22HP 24HP 28.0 33.5 40.0 45.0 50.4 56.0 61.5 68.0 95,500 114,300 136,500 153,600 172,000 191,100 209,900 232,000 24,080 28,810 34,400 38,700 43,340 48,160 52,890 58,480 Combination use (2 Outdoor units) Capacity Model Index : kW BTU / h kcal / h 26HP 28HP 30HP 32HP 34HP 36HP 38HP 40HP 42HP 44HP 46HP 48HP 73.5 80.0 85.0 90.0 96.0 101.0 106.5 113.0 118.0 123.5 130.0 136.0 250,800 273,000 290,100 307,100 327,600 344,700 363,400 385,600 402,700 421,400 443,600 464,100 63,210 68,800 73,100 77,400 82,560 86,860 91,590 97,180 101,480 106,210 111,800 116,960 4HP FDC112KXEN6 FDC112KXES6 5HP FDC140KXEN6 FDC140KXES6 6HP FDC155KXEN6 FDC155KXES6 1phase 220V 3phase 220V 3phase 380V 8HP FDC224KXE6M FDC224KXE6G 10HP FDC280KXE6M FDC280KXE6G 12HP FDC335KXE6M FDC335KXE6G 12HP FDC335KXE6M-K FDC335KXE6-K 14HP FDC400KXE6M FDC400KXE6 16HP FDC450KXE6M FDC450KXE6 18HP FDC504KXE6M FDC504KXE6 20HP FDC560KXE6M FDC560KXE6 20HP FDC560KXE6M-K FDC560KXE6-K 22HP FDC615KXE6M FDC615KXE6 24HP FDC680KXE6M FDC680KXE6 26HP FDC735KXE6M 12+14 FDC335KXE6M-K FDC400KXE6M FDC735KXE6 12+14 FDC335KXE6-K FDC400KXE6 28HP FDC800KXE6M 14+14 FDC400KXE6M FDC400KXE6M FDC800KXE6 14+14 FDC400KXE6 FDC400KXE6 30HP FDC850KXE6M 14+16 FDC400KXE6M FDC450KXE6M FDC850KXE6 14+16 FDC400KXE6 FDC450KXE6 32HP FDC900KXE6M 16+16 FDC450KXE6M FDC450KXE6M FDC900KXE6 16+16 FDC450KXE6 FDC450KXE6 34HP FDC960KXE6M 16+18 FDC450KXE6M FDC504KXE6M FDC960KXE6 16+18 FDC450KXE6 FDC504KXE6 36HP FDC1010KXE6M 18+18 FDC504KXE6M FDC504KXE6M FDC1010KXE6 18+18 FDC504KXE6 FDC504KXE6 38HP FDC1065KXE6M 18+20 FDC504KXE6M FDC560KXE6M FDC1065KXE6 18+20 FDC504KXE6 FDC560KXE6 40HP FDC1130KXE6M 20+20 FDC560KXE6M FDC560KXE6M FDC1130KXE6 20+20 FDC560KXE6 FDC560KXE6 42HP FDC1180KXE6M 20+22 FDC560KXE6M-K FDC615KXE6M FDC1180KXE6 20+22 FDC560KXE6-K FDC615KXE6 44HP FDC1235KXE6M 22+22 FDC615KXE6M FDC615KXE6M FDC1235KXE6 22+22 FDC615KXE6 FDC615KXE6 46HP FDC1300KXE6M 22+24 FDC615KXE6M FDC680KXE6M FDC1300KXE6 22+24 FDC615KXE6 FDC680KXE6 48HP FDC1360KXE6M 24+24 FDC680KXE6M FDC680KXE6M FDC1360KXE6 24+24 FDC680KXE6 FDC680KXE6 FDC335KXE6-K/KXE6M-K & FDC560KXE6-K/KXE6M-K are only used for combining with other models. 4 <Indoor units> Wide variety of 13 types 75 models A range of 13 types of exposed or concealed indoor units.25HP 1.6HP 2HP 2. in wide capacities.5HP 3.8HP 1HP 1.2HP 4HP 15 22 28 36 45 56 71 90 112 5HP 6HP 8HP 10HP 140 160 224 280 NEW NEW 2way FDTW 1way FDTS 1way Compact FDTQ NEW Duct Connected NEW High Static Pressure FDU Low/Middle Static Pressure FDUM NEW NEW Low Static Pressure (thin) FDUT Compact & Flexible FDUH Wall Mounted FDK Ceiling Suspended FDE Floor Standing 2way OA Processing unit FDFW FDU-F 5 . 75 indoor models. The best selection of indoor units for many kinds of rooms and preference can be available from our full lineup.5HP 0. Indoor units lineup Capacity Type Ceiling Cassette Model Code : kW 4way FDT 4way Compact (600 x 600) FDTC 0. R410A eco touch REMOTE CONTROL(option) Advanced touch screen panel with full dot Liquid Crystal display User friendly •LCD panel with light tap operation introduced as the industry's first •Simple interface with only three buttons High level of visibility •Big LCD with 3. 25ºC in auto mode. •Operation correction by outdoor temperature Simple setting by tapping button only 6 .8 inch full dot display •Back light function •Multi language display (9 languages) NEW RC-EX1A Run / Stop High power operation Energy-saving operation The highest capacity operation (Max 15 minutes) •Increasing compressor speed •Increasing air flow volume •Changes set temperature. At 28ºC in cooling mode and 22ºC in heating mode. 2. Outdoor unit Indoor unit eco touch Remote Control USB eco touch Remote Control RC-EX1A Utility Software 7 . Indoor unit and remote control settings can be programmed by PC and uploaded to controller via USB.1.5ºC Convenience Service LCD contrast setting Error code display Back light setting Operation data display Filter sign Next service date display Control sound Contact company display Outdoor silent mode USB connection (mini-B) Summer time setting Home leave mode Indoor & outdoor temperature display Heating standby display Defrosting operation display Auto cooling/heating display ºC/ºF display Administrator settings Room name setting eco touch Remote control RC-EX1A Series Utility Software By connecting this system to the eco touch Remote Control. the eco touch Remote Control can be operated from PC. Main functions Saving energy Comfort Sleep timer Peak cut timer Automatic temperature set back Weekly timer Set ON/OFF timer by hour Set ON/OFF timer by clock Individual flap control High power operation External ventilation ON/OFF Warming up operation Automatic fan speed Temperature increment setting by 0. Basic operation All settings done by tapping touch screen panel Operation mode Operation mode setting screen Cooling Fan Dry Heating Auto Setting temperature screen The desired operation mode can be selected by simply tapping this button. You can select the temperature as desired by tapping button. R410A 1. High Efficiency (KX6) The industry's highest COP levels (380V series) We have cleared the class A standard, the highest energy saving level, with our high COP (Coefficient Of Performance). A EER in Cooling COP 4.5 3.2 4.00 4.0 3.5 COP in Heating CLASS 4.0 3.46 3.41 3.55 3.47 3.42 3.34 3.36 3.29 COP 4.5 4.15 3.71 3.72 A CLASS 3.6 3.84 3.71 3.84 3.82 3.74 3.75 3.5 3.0 3.0 2.5 2.5 5 6 8 10 12 14 16 18 20 HP 5 6 8 10 12 14 16 18 20 HP (ISO-T1 conditions) = Capacity[kW] / Power Consumption[kW] *COP COP across the KX6 range ensures reduced running costs and reduced environmental impact. * 2. Compact Design 4~6HP Volume 1FAN 35% less Weight 32% less KX4 H1300 x W970 x D370mm 125kg / 0.47m3 • Transportation Becomes much easier • Easier to hide behind the fence (Harmonic Appearance) KX6 H845 x W970 x D370mm 85kg / 0.30m3 (FDC112/140/155KXEN6) 2FAN 8~12HP Volume 47% less Weight 10% less KX4 H1690 x W1350 x D720mm 245kg / 0.97m3 8 • Transportation Becomes much easier KX6 H1675 x W1080 x D480mm 221kg / 0.52m3 (FDC224KXE6G) High efficiency and compact design are realized applying the various advanced functions 4~6HP Compact High Efficient Heat Exchanger Compact high efficiency Heat Exchanger New Inverter Control Vector Inverter Control system • Optimizing relationship of the air flow velocity & fin pattern • Improvement of air distribution Maximizing efficiency of heat exchanger New Twin Rotary Compressor Heat Exchanger DC Fan Motor Compact & High efficiency KX4 KX6 Optimum New Refrigerant System Control 8~12HP New DC Fan motor Compact & High efficiency New Inverter Control Compact & Vector Inverter Control system Downsized accumulator Receiver in fan section 3D-Scroll Compressor (12HP) KX4 KX6 14~48HP DC Fan Motor Tetrahedral structure of Heat Exchanger Expansion of Heat Exchanger Double tube New Inverter Control 3D-Scroll Compressor (22,24HP) 9 R410A 3D Scroll Compressor Unit start up speed in heating mode drastically improved for lower outdoor temperature operation. Present scroll 3D scroll Lower at the inside Same height Higher at the outside Fixed scroll Orbital scroll 2-Dimension compression Downsizing High Efficiency High Endurance High strength due to the lower teeth inside 3-Dimension compression 3D scroll compressor has the different height scroll at the outside and the inside. A high compression ratio is improved by compressing the refrigerant both radially and axially. 3-Dimension Compression has been realized with a much higher efficiency even if compression ratio is high. The strength of the scroll is improved by reducing the height of the inner wrap, which receives a heavy load. 3D compressors are applied for 12HP, 20HP, 22HP & 24HP. New Inverter Control (Vector control) New Inverter Control has applied new advanced technology of Vector control and has realized high efficiency. • Smooth operation from low speed to high speed • Smooth Sine Voltage Wave form are attained • Energy efficiency is further improved in low speed range Compact Integrated PCB • Control Box size reduction • PCB size reduced by 50 % Control PCB: Single-sided board Double-sided board Inverter PCB: Power transistor size reduction • New Superlink system control • New Design method applied Control PCB Optimum Refrigerant System Control We have improved refrigeration circuit from our long experience and have realized following Optimum Refrigerant System Control. • Optimum heat exchanger refrigerant distribution • Advanced refrigerant liquid return protection control system • High speed system control by new Superlink system • Use of larger diameter for suction piping and discharge piping and redesigned of double tube DC Fan Motor KX6 Long-chorded 3 propeller fan with serration Employment of DC fan motor has enabled to realize an excellent efficiency of approximate 60% higher than previous models. Rotor(Squirrel Cage made of conductor) Stator (coil) Rotor(made of permanent magnet) Stator (coil) 10 KX4 Fan blade design adapted from MHI's aerospace division - with serrated edges that deliver increased air volume with less power input. Serration 3. Design Flexibility Increased indoor unit connection capacity KX6 series(4~34HP) can connect indoor unit capacity up to 150~200% from 130% of previous models. If the connection capacity of indoor units is more than 100%, capacity of each indoor unit may be affected by connection capacity ratio. Capacity connection HP KX4 5~12 130% HP KX6 4~12 150% 14,16 130% 14,16 200% 18~34 130% 18~34 160% 36~48 130% 36~48 130% • In case that capacity connection is more than 130%, additional charge of refrigerant is required on site. • In case of 8-34HP of KX6 system, if one or more indoor units of FDK and/or FDFW series are connected to the system, the total connecting capacity of indoor units should not exceed 130%. KX6 14,16HP KX4 130% capacity connection KX6 200% capacity connection More connectable indoor units Number of connectable indoor unit KX6 enable more connectable indoor units (per kW), compared with former model KX4. Thanks to a new lineup of FDTC15KXE6 & FDUT15KXE6-E, number of connectable indoor units for KX6 has increased further. 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5 0 KX6 KX4 4 5 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 HP Control Systems KX6 series offer wide variation of control system and provide the best solution. [KX6 Control system units with SUPERLINK- ] Classification Individual controller Wired Wireless Push buttons Touch screen Center Console Model Type PC windows interface units RC-E5 RC-EX1A RCN-T-36W-E etc. SC-SL1N-E SC-SL2NA-E SC-SL4-AE SC-SL4-AB SC-WGWNB-A SC-WGWNB-B SC-BGWNA-A SC-BGWNA-B SC-LGWNA-A BMS interface BACnet units Lonworks Please refer to page 70 . 71 for INTESIS BMS interface. Connectable Indoor units (Maximum) 1 1 1 16 64 128 128 128(64x2) 128(64x2) 128(64x2) 128(64x2) 96(48x2) Electric power calculation 11 675 x W1.080 x D480 Easy transportation 800 KX6(14~48HP) is portable and the uniform reduced footprint allows neat. continuous installation. transportation in an elevator made for six persons (Width:1400mm. Open area:800mm) is possible. 1350mm 12 1350mm 1350mm . As a result of the adoption of thinner refrigerant piping and refrigerant volume reductions.R410A Long Pipe Length Piping length has extended max height difference between indoor units from 4m to 18m and enables us to put indoor unit on extra three floors.400 Transportation in an elevator made for six persons 8~12HP (KX6) 850 H1. additional charge of refrigerant and oil on site is required. (2)In case indoor unit connection capacity is 130% or more or total piping length is 510m or more. Easy Transportation & Installation Due to realization of significant reduction in size and foot print which is one of the smallest in the industry. (1)Divide up the refrigerant system into independent refrigeration circuit systems in case required additional refrigerant on site is 50kg or more for 14~24HP and 100kg or more for 26~48HP. 1. Height difference 50m(outdoor unit above) 40m(outdoor unit below) Max height difference between indoor units: 15m 18m Furthest indoor unit: 160m unit piping from the first branch must be within 40m. Refer to our Installation Manual for details.4m Outdoor unit Indoor unit Indoor unit Indoor unit From the first branch to the furthest * indoor unit: 40m 90m Furthest indoor unit: 160m * The difference between the longest and the shortest indoor unit piping from the first branch must be within 40m. 8~12HP 14~48HP Total length: 510m Max: 10m Total length: 510 1000m Outdoor unit To the first branch: max 130m Indoor unit Indoor unit From the first branch to the furthest indoor unit: 40m 90m* Indoor unit * The difference between the longest and the shortest indoor Height difference 50m(outdoor unit above) 40m(outdoor unit below) Max: 5m To the first branch: max 130m Max height difference between indoor units: 4m 18m Max: 0. eliminating cost of a crane and reducing labor. the industry's longest 160 m actual piping length or 1000m total piping length is realized. Depth:850. proper operation of EEV (Electrical Expansion Valve) can be checked automatically in cooling operation. Serviceability Easy Service Check Operation (8~48HP) Quick and easy access to service parts by separation of compartments.25mm2. crossing connection of refrigerant piping and electrical wiring. KX4 KX6 1000m 1500m 4. Heating KX6 -20ºC +15. The max length of 2-core can be 1500m from 1000m of previous models. The check should be done in one refrigerant system. This check operation can be done at 0~43ºC outdoor temperature and 10~32ºC indoor temperature by use of outdoor unit dip switch. dip switch Blower compartment Mechanical compartment 13 . It takes 15~30 minutes and avoids frequent failure by preventing careless mistakes during installation.Wide Range of Operation KX6 series permits a system design considering a heating range operation under a low temperature condition up to -20ºC from -15ºC of previous model and a cooling range operation under -15ºC from -5ºC of that.5ºC KX4 -15ºC Cooling KX6 -15ºC -5ºC +43ºC KX4 -20 -10 0 10 20 30 40 For the capacities under low temperature conditions. refer to technical manual.75mm2 to 1. Closing of Service valve. 50 Max length of electrical wiring The wiring must be a 2-core shielded cable size 0. the system will keep operating with good compressor. corrosion resistance has been improved compared to current models.58 ø31.22 10 12 ø25. which will help reduce piping work cost.92] 30 ø15.1[ø34.05 ø22. mm ø9.22 ø25.8 inch 3/8" 14 1/2" 5/8" 3/4" 7/8" 1" 11/8" 11/4" 13/8" 11/2" 13/4" 2" Blue Fin Due to application of blue coated fins for the heat exchanger of new outdoor unit.5 ø50. Detailed fault diagnosis and operation history memory via 7-segment display. Should compressor be damaged.8 ø34.52 ø19. KX6 R410A 9. in the event that one unit has a failure.22 Liquid piping Gas piping ex.4[ø28.05 8 ø22. in the event of the compressor failure. all KX6 series 8~48HP 3 Layer Construction <14~48HP> Back-up Operation <14~48HP> Thanks to improvement of control box structure from 4 to 3 layer construction and by use of hinged lays.92] 42 ø19.58] 14 16 ø12.7 18 ø28.52 ø12.7 ø15. in 2 compressor module.88 ø19. service and maintenance has been made much easier for inverter components.88 32 34 36 38 40 ø38.8[ø34. . Compressor failed Keeping operation Reduced Refrigerant Volume To use the new refrigerant R410A. the system will keep operating with another unit. 4~6HP Equipped with RS232C for connection directly to your PC monitoring and service tasks made simple with our service software (“Mente PC”). In combined module. Various data can be monitored through 3-digit or 6-digit display on the outdoor unit PCB.05 44 46 48 [ ]: Pipe sizes applicable to European installations are shown in parentheses.4 ø28.92 ø38.R410A Monitoring Function KX6 series includes new feature to assist with servicing and trouble shooting. the system can be kept operating with the other unit. KX6 series have adopted thinner diameter refrigerant pipes. compressor replacement should be done as soon as possible.10HP Inverter Outdoor unit HP KX6 Liquid piping Gas piping 4 ø15. 2-compressor module.1 ø44. In.52 22.58 20 22 24 26 28 ø31. In combined module. the system can be kept operating with the good compressor.88 5 6 ø9. However as emergency measure for a limited time. especially where there are significant open plan areas to be controlled. The KX6 range has a total piping length of 1000m (14HP+) and the furthest indoor unit can be connected up to 160m (8HP+) from the outdoor unit. The range starts with a 11. up to the largest capacity single outdoor unit in the industry (24hp) with 68.heat pump systems KX6 heat pump systems operate with 2 inter-connecting pipes. These systems provide either a heating or cooling operation to all indoor units and are suitable for a wide range of applications from an individual apartment (with "Micro KX". to avoid unnecessary energy wastage. 15 . or even linked to an ambient thermostat. cooling only in summer/heating only in winter). Fixed Cooling mode/fixed heating mode (summer/winter switch): It is possible to fix the operational mode of the system (either cooling or heating) using a switch (SW3-7) on the outdoor unit PC board . thus commonly referred to as a '2-pipe system'.2kW cooling capacity. Outdoor units can also be “twinned” providing up to 48HP/136.this enables the building user to decide the operation of the system (e. 1/phase system) to an entire multi storey building. It is also possible to wire the control switch to a remote location (inside the building) to a control room.0kW on a single system.g.0kW cooling capacity. 3 RCN-TW-E Flap control system 1 2 4 The flap can swing within the range of upper and lower flap position selected with wired remote control.P. Ceiling Cassette -2 way- NEW FDTW Individual flap control system Wireless remote control According to room temperature conditions. With our new technology optimization of airflow outlet design sufficient and reach air flow is achieved. 10Pa 20Pa 30Pa 40Pa 50Pa 60Pa 70Pa 80Pa 90Pa 100Pa External static pressure (E.P.9 No.S.5 No.4 No.10 E. Refer to page 44. (this system is applied for FDT. FDTC.P.3 No. New FDUM Duct Duct Indoor unit will recognize external static pressure by itself automatically and keep rated air flow volume. Longer Duct Ceiling Keep the same air flow volume case1 case2 RC-E5 Setting No. For wireless remote control simply insert the infrared receiver kit on a corner of the panel.8 No.S. No.P.S. four directions of air flow can be controlled individually by flap control system. and FDFW type also) Selected upper position Max swing range Selected lower position * Wireless remote control and RCH-E3 is not applicable to the lndvidual flap control system and the Flap control system. 16 . Using DC motor.S.P.P.6 No.R410A DUCT CONNECTED -Middle Static pressure- FDUM NEW Automatic external static pressure (E. FDEN.2 No. DUCT CONNECTED -High Static Pressure- FDU NEW FDU has the same E. button.7 No. FDTS.) control Duct design was simplified.1 No.S.) can be set by E.S. FDK. button E. the most optimum air flow volume can be achieved by this automatic control. control. RCN-TS-E 17 .5m 2dB(A) Down 30 Unit 1m Previous New 1dB(A) Down [dB(A)] 1m Depth: 520 Sound pressure level 1m 20 29 28 24 10 22 0 New Model Hi [dB(A)] Serviceability Fan speed Previous New 5dB(A) Down 40 Lo 4dB(A) Down 30 20 Access to control 37 32 10 30 26 0 Hi Access to control Access to fan motor Current Model Access to fan motor Fan speed Lo New Model Ceiling Cassette -1 way- NEW FDTS Wireless remote control Individual flap control system For wireless remote control simply attach an additional panel with infrared receiver on the right side of the main decorative panel.DUCT CONNECTED (thin) -Low Static pressure- FDUT NEW Compact design <FDUT15~56KXE6F-E> Height: 220 200mm Lower noise <FDUT28KXE6F-E> 20mm less!! 2m Current Model 500mm 1. Two directions of air flow can be controlled individually by flap control system. 5ºC 10 0 Heating -10 -15ºC Furthest indoor unit: 70m -20 -20ºC * The total length of ø9.5 14.9 2.17 4. • High efficiency with COP (in cooling) up to 4.0 52/54 53/55 53/56 52/54 53/55 53/56 6 8 8 ø9.5 5HP 1 Phase 220V.0 16.7 4.9 7.0kW (380V) 15.5 4.0 16.5 4.5kW) Model No.5kW (380V) • The KX6 heat pump 2-pipe systems offer high performance VRF for applications that require either cooling only or heating only.3 21. 6hp (11. • Connect up to 8 indoor units/up to 150% capacity. Sound pressure level indicates the value in an anechoic chamber.0 15. Specifications Item Nominal horse power Power source Model Cooling kW Heating A Starting current Cooling Power kW Electrical characteristics consumption Heating Cooling Running A current Heating mm Exterior dimensions HxWxD kg Net weight kg Refrigerant charge R410A dB(A) Cooling/Heating Sound pressure level Liquid line mm(in) Refrigerant piping size Gas line % Capacity connection Number of connectable indoor units Nominal capacity FDC112KXEN6 FDC140KXEN6 FDC155KXEN6 FDC112KXES6 FDC140KXES6 FDC155KXES6 4HP 6HP 4HP 15. of 20ºCDB.5 16. of 7ºCDB.0kW (220V) 15.2 4.3 11.5m. Cooling: Indoor temp. FDC112KXEN6 FDC140KXEN6 FDC155KXEN6 FDC112KXES6 FDC140KXES6 FDC155KXES6 Nominal Cooling Capacity 11. 60Hz 14.38 23.2kW (380V) 14.52mm(3/8") liquid piping must be 50m or less Note: FDUT15KXE6F-E and FDTC15KXE6F can not be connected to the above systems. of 35ºCDB.31 20.5 16. 18 .3 5 845x970x370 85 87 5. Piping length is 7. • Industry leading total piping length up to 100m and a maximum pipe run of 70m.3 2.89 4. 6ºCWB. and outdoor temp.R410A Outdoor units Heat pump systems 4. 60Hz 14. The data are measured under the following conditions(ISO-T1).6 21.1 4. During operation these values are somewhat higher due to ambient conditions. of 27ºCDB.0 6HP 11.2 12.5kW (220V) 11.80 2. Total length: 100m Range of operation Outdoor unit 50 +43ºC Height difference 40 30m(outdoor unit above) 15m(outdoor unit below) 30 Indoor unit difference between indoor units: 15m Indoor unit Cooling 20 Max height +15. 5.0. ideal for open plan areas.31 6.71 4. Heating: Indoor temp.5 5HP 3 Phase 380V. • KX6 employs DC inverter compressors ONLY.8 7.38 7. 2.88(5/8") 80~150 6 8 8 1.2kW (220V) 14.71 4. and outdoor temp.52(3/8") ø15. 19ºCWB.2kW~15.80 2.17 4.89 13.2 12. (6) The unit name plate is attached on the lower right corner of the front panel.52 Dimensions All measurements in mm. (3) Where the unit is subject to strong winds. B 36 40 51 A L3 L2 Intake L4 100 Intake L1 outlet Terminal block Service space B Minimum installation space A 845 A 15 970 110 195 L1 L2 L3 L4 50 279 242 110 55 50 50 10 C 195 F 52 27 50 C I II II Open Open 500 300 5 Open 150 300 150 5 5 5 1m overhead clearance required VIEW A Mark A B C D E F Item Service valve connection (gas side) Service valve connection (liquid line) Pipe/cable draw-out port Drain discharge port Anchor bolt hole Cable draw-out port ø15.88 (5/8") (flare) ø9.Refrigerant piping Outdoor unit (HP) Gas pipe Liquid pipe 4 Furthest indoor unit =<70m 5 6 Branch pipes Header pipe DIS-22-1/DIS-180-1 HEAD6-180-1 ø15. lay it in such a direction that the blower outlet faces perpendicularly to the dominant wind direction. (2) The unit must be fixed with anchor bolts. 19 . (4) Leave a 1m or larger space above the unit.52 (3/8") (flare) 4 places ø20 x 3 places M10 x 4 places ø30 x 3 places Notes: (1) It must not be surrounded by walls on the four sides. (5) A wall in front of the blower outlet must not exceed the units height. An anchor bolt must not protrude more than 15mm.88 ø9. 60Hz 33. 19ºCWB. • High efficiency with COP (in cooling) up to 4.82 6. Heating: Indoor temp.73 27.21 13. 4.4(1") [ø28.0 37.5 5 8. Cooling: Indoor temp. Sound pressure level indicates the value in an anechoic chamber. 10.03 6. Piping length is 7.5 9. ideal for open plan areas.5ºC 10 0 Heating -10 -15ºC -20 Furthest indoor unit: 160m -20ºC * The difference between the longest and the shortest indoor unit piping from the first branch must be within 40m.22(7/8") 50~150 22 24 61/61 ø12.22 13.82 10.54 1675x1080x480 215 212 FDC280KXE6G FDC335KXE6G 10HP 3 Phase 380V. 2.4kW (220V) 28.0. 6ºCWB.R410A Outdoor units Heat pump systems 8.91 23. of 20ºCDB.12 9.58(1 1/8")] 24 1.87 16.25 16. 12hp (22.52(3/8") ø19.5kW (380V) • The KX6 heat pump 2-pipe systems offer high performance VRF for applications that require either cooling only or heating only. of 7ºCDB.0 25.0 31. of 35ºCDB. 3.7(1/2") ø25.0 31. Do not connect N-phase wire to the unit when the power supply is 3-phase and 4-wire.52(3/8") ø19.4kW~33.12 15. 20 .4 28.5 58/58 59/60 ø9. • KX6 employs DC inverter compressors ONLY. Specifications Item Nominal horse power Power source Model Cooling kW Heating A Starting current Cooling Power kW Electrical characteristics consumption Heating Cooling Running A current Heating HxWxD mm Exterior dimensions kg Net weight R410A kg Refrigerant charge Cooling/Heating dB(A) Sound pressure level Liquid line mm(in) Refrigerant piping size Gas line % Capacity connection Number of connectable indoor units Nominal capacity FDC224KXE6M FDC280KXE6M FDC335KXE6M FDC224KXE6G 10HP 12HP 8HP 8HP 3Ph-3wire 220V.5 37.4 22.38 8.57 9.70 10.5m. During operation these values are somewhat higher due to ambient conditions.27 23. of 27ºCDB.5 5 6 5.09 8.41 12HP 33.05(3/4") ø22.58(1 1/8")] 24 58/58 59/60 ø9. and outdoor temp. • Connect up to 24 indoor units/up to 150% capacity.4kW (380V) 28.5 25. 60Hz 28.7(1/2") ø25. [ ] : Pipe sizes applicable to European installations are shown in parentheses.0kW (380V) 33.0kW (220V) 33. The data are measured under the following conditions(ISO-T1).5 22. and outdoor temp. FDC224KXE6M FDC280KXE6M FDC335KXE6M FDC224KXE6G FDC280KXE6G FDC335KXE6G Nominal Cooling Capacity 22.85 17.60 5. Total length: 510m To the first branch: max 130m 50 +43ºC Height difference 50m(outdoor unit above) 40m(outdoor unit below) Indoor unit 40 30 20 Max height difference between indoor units: 18m Indoor unit From the first branch to the furthest indoor unit: 90m* Range of operation Outdoor unit Indoor unit Cooling +15.36 9. • Industry leading total piping length up to 510m and a maximum pipe run of 160m.4(1") [ø28.91 27.05(3/4") ø22.5kW (220V) 22. 60Hz / 3Ph-4wire 220V.5kW) Model No.85 8.36 218 11.22(7/8") 50~150 22 24 61/61 ø12. (Gas side only) 21 .Refrigerant piping Outdoor unit (HP) Gas pipe Liquid pipe Gas pipe Liquid pipe Pipe sizes applicable to European installations.22 Branch pipes 10 12 ø22.4 (1")(Brazing) Notes: (1) It must not be surrounded by walls on the four sides.22 (7/8")(Brazing) ø25.52 Header pipe ø12. lay it in such a direction that the blower outlet faces perpendicularly to the dominant wind direction. (3) Where the unit is subject to strong winds.(Gas side only) (8) Mark shows the connecting position of the local pipe. (7) Connect the Service valve with local pipe by using the pipe of the attachment.7 (1/2") (Flare) 4places ø20 x 4places M10 x 4places ø30 x 2places (front) ø45 (side) ø30 x 2places (back) G Connecting position of the local pipe.05 (3/4") (Flare) ø19. (5) A wall in front of the blower outlet must not exceed the units height.7 ø28.22 ø28.58 ø9.10HP) 634(12HP) 1675 Terminal block D 80 Item FDC224KXE6M / KXE6G FDC280KXE6M / KXE6G FDC335KXE6M / KXE6G A Service valve connection of the attached connecting pipe (gas side) ø19. 8 Furthest indoor unit =<90m ø19. Intake L1 L2 L3 L4 L4 Intake L1 Outlet Service space 43 60 120 69 51 L3 L2 69 B A G I II II Open Open 1500 300 5 Open 300 300 300 5 5 5 Minimum installation space 1080 195 690 54 14 35 159 84 174 84 35 84 159 194 C 30 701 C 14 54 51 F 461 421 141 241 321 361 30 50 105 520 480 19 39 Mark 67 42 989 E 195 50 19 39 E 51 C F 55 C G 55 F A 55 20 B 553 640(8.05 (3/4") (Flare) B C D E Service valve connection (liquid side) Pipe/cable draw-out hole Drain discharge hole Anchor bolt hole F Cable draw-out hole ø9.05 (3/4") (Flare) ø19. (4) Leave a 1m or larger space above the unit.52 (3/8") (Flare) 4places ø20 x 4places M10 x 4places ø30 x 2places (front) ø45 (side) ø30 x 2places (back) ø12. An anchor bolt must not protrude more than 15mm.05 Furthest indoor unit =<90m ø22. (gas side) ø19.05 (3/4")(Brazing) ø22.58 ø12.7 DIS-22-1/DIS-180-1 HEAD6-180-1 DIS-371-1 Dimensions All measurements in mm.52 (3/8") (Flare) 4places ø20 x 4places M10 x 4places ø30 x 2places (front) ø45 (side) ø30 x 2places (back) ø9. (2) The unit must be fixed with anchor bolts. (6) The model name label is attached on the lower right corner of the front. 3.5 ø28.0 45. Do not connect N-phase wire to the unit when the power supply is 3-phase and 4-wire. ideal for open plan areas. and outdoor temp. 4. • High efficiency with COP (in cooling) up to 3. 6ºCWB.10 21. FDC400KXE6M FDC450KXE6M FDC400KXE6 FDC450KXE6 Nominal Cooling Capacity 40. 22 .4(1") [ø28.5 1690x1350x720 330 11.0 ø12. Cooling: Indoor temp. [ ] : Pipe sizes applicable to European installations are shown in parentheses.5/62. • Industry leading total piping length up to 1000m and a maximum Uniform footprint of models (14.0kW~45.7(1/2") ø25.97 13.5/60.0 45.0kW (220V) 40. 60Hz 40. The data are measured under the following conditions(ISO-T1).27 11. 19ºCWB.5/60.0kW) Model No.4 37. 60Hz / 3Ph-4wire 220V.58(1 1/8")] 50~200 53 62.0kW (220V) 45.0 50.0kW (380V) • The KX6 heat pump 2-pipe systems offer high performance VRF for applications that require either cooling only or heating only.4 19.5m.16hp) allows continuous side-by-side installation pipe run of 160m.73 31. During operation these values are somewhat higher due to ambient conditions.0 50.0kW (380V) 45.73 18. and outdoor temp.58(1 1/8") 60 1. Piping length is 7.1 21.4(1") [ø28. Heating: Indoor temp.R410A Outdoor units Heat pump systems 14.5ºC 10 0 Heating -10 Furthest indoor unit: 160m -15ºC -20 -20ºC *1 The difference between the longest and the shortest indoor unit piping from the first branch must be within 40m.8 12. Specifications Item Nominal horse power Power source Model Cooling kW Heating A Starting current Cooling Power kW Electrical characteristics consumption Heating Cooling Running A current Heating HxWxD mm Exterior dimensions kg Net weight R410A kg Refrigerant charge Cooling/Heating dB(A) Sound pressure level Liquid line mm(in) Refrigerant piping size Gas line % Capacity connection Number of connectable indoor units Nominal capacity FDC400KXE6M FDC450KXE6M FDC400KXE6 FDC450KXE6 14HP 16HP 14HP 16HP 3Ph-3wire 220V. Please refer to page 74. of 27ºCDB. • KX6 employs DC inverter compressors ONLY. Total length: 1000m To the first branch: max 130m Outdoor unit Range of operation Indoor unit Height difference 50m(outdoor unit above) 40m(outdoor unit below) *2 +43ºC 40 30 Max height difference between indoor units: 18m Indoor unit From the first branch to the furthest indoor unit: 90m*1 50 Indoor unit Cooling 20 +15. of 20ºCDB.58(1 1/8")] ø28.97 13. • Connect up to 60 indoor units/up to 200% capacity. 16hp (40.8 33. 60Hz 40. Sound pressure level indicates the value in an anechoic chamber.0 45. *2 Height difference up to 90m is possible with High Head series.0 3 Phase 380V.0 62.5 59.6 12.7 8 11.0 45.6. 2. of 7ºCDB. of 35ºCDB.5 ø25.58(1 1/8") 53 60 59.0 11.5/62.27 11.10 36. long hole 40 x 80 (under side) M10 x 4 places ø45 x 3 places ø20 x 10 places ø9.52(Flare) 230 x 60 Dimensions 1 2 L1 L2 L3 L4 H1 H2 H3 H4 500 Open When more than one unit is installed Wall height H3 L3 L2 L5 L6 L1 (Unit front side) Wall height H2 10 10 100 100 10 Open 1500 – No limited No limited 1000 No limited No limited – Installation example L4 Wall height H4 Notes: (1) The unit must be fixed with anchor bolts.Dimensions All measurements in mm.16Hp only) 335-K Wall height H2 Mark A B C D F G H K L Dimensions A B L1 500 Open L2 10 200 L3 100 300 L4 10 Open L5 0 400 L6 0 400 H1 1500 No restrictions H2 H3 H4 No restrictions No restrictions 1000 No restrictions No restrictions No restrictions 23 . (4) The ports for refrigerant pipe and power cable penetrations are covered with half-blanks. Please cut off a half-blank with nippers in using these ports.58(Brazing) ø12. front). (5) Use a ø88 port for refrigerant pipe connection. (2) Leave a 2m or larger space above the unit. (For 14. (3) The unit name plate is attached on the lower right corner of the front panel. Content Refrigerant gas piping connection pipe Refrigerant liquid piping connection pipe Refrigerant piping exit hole Power supply entry hole Anchor bolt hole Drain waste water hose hole Drain hole Refrigerant oil equalization piping connection pipe Carrying in or hole for hanging 400 450 ø25. (6) Anchor holes marked “L J” (four holes for M10) are for a renewal installation. (7) The oil-equalising pipe K should be used when outdoor units are used in combination.4(Brazing) Installation example ø28.7(Flare) ø88(or ø100) ø50 (right . left . 7 31. Please refer to page 74.2 28.5 64. 20. During operation these values are somewhat higher due to ambient conditions. 6ºCWB. Piping length is 7.0 A 8 14.5kW (220V) 68. 3. 60Hz / 3Ph-4wire 220V. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp.0 61.5 dB(A) 64.5/64. Total length: 1000m To the first branch: max 130m Outdoor unit Indoor unit Range of operation 50 Height difference 50m(outdoor unit above) 40m(outdoor unit below) *2 +43ºC 40 30 Max height difference between indoor units: 18m Indoor unit From the first branch to the furthest indoor unit: 90m*1 Uniform footprint of all models (from 8hp~24hp) allows continuous sideby-side installation Indoor unit 20 Cooling +15.79 20.5 63. • Connect up to 72 indoor units/up to 160% capacity.4 56. • Industry leading total piping length up to 1000m and a maximum pipe run of 160m.0 69.5kW (380V) 68. of 7ºCDB. 24hp (50.0 56. 24 .79 18.4 33.2 69. and outdoor temp.7(1/2") mm(in) ø28. ideal for open plan areas.0kW) Model No. of 20ºCDB.3 57.58(1 1/8") 50~160 % 53 59 65 72 53 59 65 72 1.98 14.48 19. Heating: Indoor temp.4.1 27.1 40.5/62. *2 Height difference up to 90m is possible with High Head series.0/63.0kW (220V) 50.0 ø12. 22.79 20.5 68. 60Hz 50.48 19. FDC504KXE6M FDC560KXE6M FDC615KXE6M FDC680KXE6M FDC504KXE6 FDC560KXE6 FDC615KXE6 FDC680KXE6 Nominal Cooling Capacity 50. Do not connect N-phase wire to the unit when the power supply is 3-phase and 4-wire.0 54.6 A 25. of 27ºCDB. and outdoor temp.73 16.6 43. • KX6 employs DC inverter compressors ONLY.5 63.5 kg 61.0 73.0 kW 56.R410A Outdoor units Heat pump systems 18.12 16.08 24.4kW (380V) 56.79 18. • High efficiency with COP (in cooling) up to 3.08 15.0 30.0 61.0 50.0kW (380V) 61.5/64.5/62.5 68. Specifications Item Nominal horse power Power source Cooling Heating Starting current Cooling Power Electrical characteristics consumption Heating Cooling Running current Heating HxWxD Exterior dimensions Net weight R410A Refrigerant charge Cooling/Heating Sound pressure level Liquid line Refrigerant piping size Gas line Capacity connection Number of connectable indoor units Nominal capacity Model FDC504KXE6M FDC560KXE6M FDC615KXE6M FDC680KXE6M FDC504KXE6 FDC560KXE6 FDC615KXE6 FDC680KXE6 18HP 20HP 22HP 24HP 18HP 20HP 22HP 24HP 3Ph-3wire 220V.0kW (220V) 61.0 63.0/63.0 61.4kW~68.12 16.0/65.0 73.6 47.0kW (380V) • The KX6 heat pump 2-pipe systems offer high performance VRF for applications that require either cooling only or heating only.0 69. 2.3 41. 19ºCWB.0 65.6 mm 2048x1350x720 352 371 kg 352 371 11.37 24.4 56. of 35ºCDB.5m.5ºC 10 0 Heating -10 Furthest indoor unit: 160m -15ºC -20 -20ºC *1 The difference between the longest and the shortest indoor unit piping from the first branch must be within 40m.37 24.6 48. Sound pressure level indicates the value in an anechoic chamber.98 kW 15.4 53.0/65.73 16.0 63.4kW (220V) 56.0 65. 60Hz 3 Phase 380V. left . long hole 40 x 80 (under side) M10 x 4 places ø45 x 3 places ø20 x 10 places ø9.58(Brazing) ø12. front). (6) Anchor holes marked “L J” (four holes for M10) are for a renewal installation. Mark A B C D F G H K L Content Refrigerant gas piping connection pipe Refrigerant liquid piping connection pipe Refrigerant piping exit hole Power supply entry hole Anchor bolt hole Drain waste water hose hole Drain hole Refrigerant oil equalization piping connection pipe Carrying in or hole for hanging Installation example ø28. (3) The unit name plate is attached on the lower right corner of the front panel. (7) The oil-equalising pipe K should be used when outdoor units are used in combination. (5) Use a ø88 port for refrigerant pipe connection. (4) The ports for refrigerant pipe and power cable penetrations are covered with half-blanks. (2) Leave a 2m or larger space above the unit. 25 . Please cut off a half-blank with nippers in using these ports.7(Flare) ø88(or ø100) ø50 (right .Dimensions All measurements in mm.52(Flare) 230 x 60 Dimensions 1 2 L1 L2 L3 L4 H1 H2 H3 H4 500 Open 10 10 100 100 10 Open 1500 – No limited No limited 1000 No limited No limited – Notes: (1) The unit must be fixed with anchor bolts. 4 75.5 16 20.8(1 1/4") [ø34.0 95.5x2 ø15.20 32.46 36. The data are measured under the following conditions(ISO-T1). of 7ºCDB.5m. *2 Height difference up to 90m is possible with High Head series.0 85.6. Do not connect N-phase wire to the unit when the power supply is 3-phase and 4-wire. and outdoor temp. • Connect up to 80 indoor units/up to 160% capacity. of 20ºCDB.83 39. • KX6 employs DC inverter compressors ONLY.3 78 80 80 335KXE6-K 400KXE6 26HP 73.92(1 3/8")] 50~160 78 80 400KXE6 400KXE6 400KXE6 450KXE6 28HP 30HP 3 Phase 380V.21 20.9 59. Heating: Indoor temp.83 68.0 100. ideal for open plan areas.2 24.5kW~90.46 63.5 90.0kW (380V) 90.2 71.66 56.5 80. 19ºCWB.54 23.24 24.20 42.0kW (220V) 90.5kW (220V) 80. 6ºCWB.0 90. 28. 60Hz 80.3 25. Sound pressure level indicates the value in an anechoic chamber.0kW (220V) 85.3 22. FDC735KXE6M (FDC335-K+FDC400) FDC800KXE6M (FDC400x2) FDC850KXE6M (FDC400+FDC450) FDC900KXE6M (FDC450x2) FDC735KXE6 (FDC335-K+FDC400) FDC800KXE6 (FDC400x2) FDC850KXE6 (FDC400+FDC450) FDC900KXE6 (FDC450x2) Nominal Cooling Capacity 73. 60Hz 73.66 26.0 1690x2700x720 660 11.0 20.0 82. 3. 30. 2.6 67.21 25.0 22.9 72. • Industry leading total piping length up to 1000m and a maximum pipe run of 160m.5 41.88(5/8") ø31.0kW) Model No.0kW (380V) • The KX6 heat pump 2-pipe systems offer high performance VRF for applications that require either cooling only or heating only. Cooling: Indoor temp. Piping length is 7.2 43.0 90.24 24. Total length: 1000m To the first branch: max 130m Outdoor unit Indoor unit Range of operation 50 Height difference 50m(outdoor unit above) 40m(outdoor unit below) *2 +43ºC 40 30 Max height difference between indoor units: 18m Indoor unit From the first branch to the furthest indoor 1 unit: 90m* Uniform footprint of all models (from 8hp~24hp) allows continuous side-byside installation Indoor unit 20 Cooling +15.5ºC 10 0 Heating -10 -15ºC Furthest indoor unit: 160m -20 -20ºC *1 The difference between the longest and the shortest indoor unit piping from the first branch must be within 40m. of 35ºCDB.0kW (220V) 73.5kW (380V) 80.8 34.0 85. 32hp (73.0kW (380V) 85.6 24. Please refer to page 74.4 80 80 80 1. 60Hz / 3Ph-4wire 220V.8 39.54 23.0 95.94 20.94 26. • High efficiency with COP (in cooling) up to 3.0 450KXE6 450KXE6 32HP 90.5 82.R410A Outdoor units Heat pump combination systems 26. 4. 26 . During operation these values are somewhat higher due to ambient conditions. and outdoor temp. Specifications Item Model FDC735KXE6M FDC800KXE6M FDC850KXE6M FDC900KXE6M FDC735KXE6 FDC800KXE6 FDC850KXE6 FDC900KXE6 Combination (FDC) Nominal horse power Power source Cooling kW Heating A Starting current Cooling Power kW Electrical characteristics consumption Heating Cooling Running A current Heating HxWxD mm Exterior dimensions kg Net weight R410A kg Refrigerant charge Liquid line mm(in) Refrigerant piping size Gas line % Capacity connection Number of connectable indoor units Nominal capacity 335KXE6M-K 400KXE6M 400KXE6M 450KXE6M 400KXE6M 400KXE6M 450KXE6M 450KXE6M 26HP 28HP 30HP 32HP 3Ph-3wire 220V. [ ] : Pipe sizes applicable to European installations are shown in parentheses.0 100. of 27ºCDB. Mark A B C D F G H K L Content Refrigerant gas piping connection pipe Refrigerant liquid piping connection pipe Refrigerant piping exit hole Power supply entry hole Anchor bolt hole Drain waste water hose hole Drain hole Refrigerant oil equalization piping connection pipe Carrying in or hole for hanging 335-K 400 ø25.52(Flare) 230 x 60 Installation example Dimensions 1 2 L1 L2 L3 L4 H1 H2 H3 H4 500 Open 10 10 100 100 10 Open 1500 – No limited No limited 1000 No limited No limited – Notes: (1) The unit must be fixed with anchor bolts. (4) The ports for refrigerant pipe and power cable penetrations are covered with half-blanks. 27 .4(Brazing) 450 ø28.7(Flare) ø88(or ø100) ø50 (right . front). (2) Leave a 2m or larger space above the unit. (6) Anchor holes marked “L J” (four holes for M10) are for a renewal installation. long hole 40 x 80 (under side) M10 x 4 places ø45 x 3 places ø20 x 10 places ø9.Dimensions All measurements in mm. (3) The unit name plate is attached on the lower right corner of the front panel. left . (7) The oil-equalising pipe K should be used when outdoor units are used in combination. (5) Use a ø88 port for refrigerant pipe connection. Please cut off a half-blank with nippers in using these ports.58(Brazing) ø12. 5 113.0 123.4 126.0kW) Model No.0 Cooling kW 108.96 38.0 101. and outdoor temp.0kW 136.0kW 101.88(5/8") mm(in) Refrigerant piping size Gas line ø31.6 2048x2700x720 704 742 11.5x2 680KXE6M 680KXE6M 48HP 136. *2 Height difference up to 90m is possible with High Head series.0kW 136.05(3/4") ø38.2 Cooling Running A current 81. • KX6 employs DC inverter compressors ONLY.0 107.5kW 130. 4.6 104.56 88. Piping length is 7. 46.0 132.5m.0 49.5.4 106.5kW 130.16 138.1 87. 3.9 94.5 130.0 142. [ ] : Pipe sizes applicable to European installations are shown in parentheses.0 118.92(1 3/8")] 50~130 80 1.5ºC 10 0 Heating Furthest indoor unit: 160m *1 The difference between the longest and the shortest indoor unit piping from the first branch must be within 40m.0kW 118.0 Heating A Starting current 27.5kW 113. Please refer to page 74.91 33. Cooling: Indoor temp.0 113. 19ºCWB.22 30. ideal for open plan areas. of 35ºCDB.52 33.46 Cooling Power kW Electrical characteristics consumption Heating 28.0kW 118. 38. 36.5kW 113.0kW (220V) (220V) (220V) (220V) (220V) (220V) (220V) (220V) (380V) (380V) (380V) (380V) (380V) (380V) (380V) (380V) • The KX6 heat pump 2-pipe systems offer high performance VRF for applications that require either cooling only or heating only. Do not connect N-phase wire to the unit when the power supply is 3-phase and 4-wire.2 Heating HxWxD mm Exterior dimensions kg Net weight 682 R410A kg Refrigerant charge Liquid line ø15.74 45.27 36. • Industry leading total piping length up to 1000m and a maximum pipe run of 160m. of 7ºCDB. 40.5 114.0 119. The data are measured under the following conditions(ISO-T1).0 83.0kW 106. of 20ºCDB.96 37.35 31. Sound pressure level indicates the value in an anechoic chamber.1(1 1/2")[ø34. 6ºCWB. FDC960KXE6M (FDC450+FDC504) FDC1010KXE6M (FDC504x2) FDC1065KXE6M (FDC504+FDC560) FDC1130KXE6M (FDC560x2) FDC1180KXE6M (FDC560-K+FDC615) FDC1235KXE6M (FDC615x2) FDC1300KXE6M (FDC615+FDC680) FDC1360KXE6M (FDC680x2) FDC960KXE6 (FDC450+FDC504) FDC1010KXE6 (FDC504x2) FDC1065KXE6 (FDC504+FDC560) FDC1130KXE6 (FDC560x2) FDC1180KXE6 (FDC560-K+FDC615) FDC1235KXE6 (FDC615x2) FDC1300KXE6 (FDC615+FDC680) FDC1360KXE6 (FDC680x2) Nominal Cooling Capacity 96. and outdoor temp.8(1 3/4")[ø34.16 40.R410A Outdoor units Heat pump combination systems 34.70 29.8 92.0kW 101.0kW 96.0 16 31.24 78. 48hp (96.58 37.4 109. Heating: Indoor temp.58 35. 60Hz / 3Ph-4wire 220V. • Connect up to 80 indoor units/up to 130% (960KXE6:160%) capacity. 42.5 127.0 96.0kW~136. Total length: 1000m To the first branch: max 130m Outdoor unit Range of operation Indoor unit Indoor unit From the first branch to the furthest indoor unit: 90m *1 Indoor unit Height difference 50m(outdoor unit above) 40m(outdoor unit below) *2 50 +43ºC 40 30 Max height difference between indoor units: 18m 20 Cooling +15. -10 -15ºC -20 -20ºC Specifications Item Combination (FDC) Nominal horse power Power source Model FDC960KXE6M FDC1010KXE6M FDC1065KXE6M FDC1130KXE6M FDC1180KXE6M FDC1235KXE6M FDC1300KXE6M FDC1360KXE6M 450KXE6M 504KXE6M 34HP 504KXE6M 504KXE6M 36HP 96. 28 .0kW 123. 2. of 27ºCDB. 44.8 101. During operation these values are somewhat higher due to ambient conditions. • High efficiency with COP (in cooling) up to 3.0 146.92(1 3/8")] % 50~160 Capacity connection Number of connectable indoor units Nominal capacity 504KXE6M 560KXE6M 560KXE6M-K 615KXE6M 615KXE6M 560KXE6M 560KXE6M 615KXE6M 615KXE6M 680KXE6M 38HP 40HP 42HP 44HP 46HP 3Ph-3wire 220V.0 138.0kW 123.2 ø19.0kW 106. 60Hz 106. 92(1 3/8")] 50~130 80 1.0 58.2 Cooling Running A current 46. (7) The oil-equalising pipe K should be used when outdoor units are used in combination.46 Cooling Power kW Electrical characteristics consumption Heating 28. (4) The ports for refrigerant pipe and power cable penetrations are covered with half-blanks.24 45.0 40.0 136. During operation these values are somewhat higher due to ambient conditions.2 48. 2. long hole 40 x 80 (under side) M10 x 4 places ø45 x 3 places ø20 x 10 places ø9.0 142. and outdoor temp. Piping length is 7.92(1 3/8")] % 50~160 Capacity connection Number of connectable indoor units Nominal capacity Dimensions 504KXE6 560KXE6 38HP 106.96 66. Please cut off a half-blank with nippers in using these ports. [ ] : Pipe sizes applicable to European installations are shown in parentheses.27 54.3 49. The data are measured under the following conditions(ISO-T1).0 Heating A Starting current 27.5x2 ø19.91 51.52 31. Sound pressure level indicates the value in an anechoic chamber.6 63. 6ºCWB.0 132.22 30. Cooling: Indoor temp.5 53. 60Hz 113. left .5m. 29 .Dimensions All measurements in mm. of 7ºCDB.9 50.4 Heating HxWxD mm Exterior dimensions kg Net weight 690 R410A kg Refrigerant charge Liquid line ø15.8 60. 19ºCWB.1(1 1/2")[ø34.0 127.5 119.52(Flare) 230 x 60 Notes: (1) The unit must be fixed with anchor bolts.5 31. Mark A B C D F G H K L Content Refrigerant gas piping connection pipe Refrigerant liquid piping connection pipe Refrigerant piping exit hole Power supply entry hole Anchor bolt hole Drain waste water hose hole Drain hole Refrigerant oil equalization piping connection pipe Carrying in or hole for hanging Installation example ø28.05(3/4") ø38.70 29.0 Cooling kW 108.0 146.7 2048x2700x720 712 615KXE6 615KXE6 44HP 615KXE6 680KXE6 46HP 680KXE6 680KXE6 48HP 123. of 35ºCDB. FDC960KXE6 FDC1010KXE6 FDC1065KXE6 FDC1130KXE6 FDC1180KXE6 FDC1235KXE6 FDC1300KXE6 FDC1360KXE6 450KXE6 504KXE6 34HP 504KXE6 504KXE6 36HP 96.35 37.16 80.5 138.0 16 33.58 37. of 20ºCDB. front).2 560KXE6 560KXE6-K 560KXE6 615KXE6 40HP 42HP 3 Phase 380V. (2) Leave a 2m or larger space above the unit. and outdoor temp. Item Combination (FDC) Nominal horse power Power source Model 1 2 L1 500 Open L2 10 10 L3 100 100 Open L4 10 H1 1500 – H2 No limited No limited H3 1000 No limited H4 No limited – (5) Use a ø88 port for refrigerant pipe connection. (6) Anchor holes marked “L J” (four holes for M10) are for a renewal installation.58 35. 3.5 56.4 45. of 27ºCDB.0 113.2 750 11.74 36.4 62.16 33. (3) The unit name plate is attached on the lower right corner of the front panel.8(1 3/4")[ø34.7(Flare) ø88(or ø100) ø50 (right .58(Brazing) ø12. Heating: Indoor temp.0 118.96 38.0 101.56 73.88(5/8") mm(in) Refrigerant piping size Gas line ø31.0 130.2 61. R410A refrigerant piping Installation of Interconnecting Pipework Mitsubishi KX6 equipment is manufactured to the highest standards of quality and reliability. Additional Refrigerant Additional R410A refrigerant only shall be used. The copper tube must be selected taking into account the higher operating pressures of R410A refrigerant. allowing unrestricted flow of refrigerant. The branch pipes shall be installed in accordance with the manufacturer’s instructions. must be prevented during the installation procedure. and sealing of insulation joints. it is not permitted to use standard fittings such as elbows. to ensure trouble free operation and long term reliability. tees etc. and must be charged by weight only. The refrigeration quality tube must be soft drawn seamless high grade copper pipe. Refrigeration quality copper tube must be used. After the installation of pipework. using dry nitrogen. and the supplied manifold kits must be used to make connections between outdoor units (where applicable). The amount of additional refrigerant must be accurately calculated from the manufacturer’s data. using electronic scales. The ingress of moisture. must be used to make connections to indoor units. and in accordance with European standard E378:2000. All brazed joints shall be made with dry nitrogen purge to ensure the prevention of oxidisation to the internal surface of the copper pipes. the pipework must be pressure tested for leakage. The interconnecting pipework must be installed by a competent and trained engineer. and air conditioning units. prior to the connection of the outdoor units. based on the length and diameter of each section of the liquid refrigerant pipework of the system. dirt and any other contaminants to the interior of the copper pipes. and that high pressures will occur throughout the system because of the reverse cycle operation. All pipework material used should be EN12735 European standard. Single outdoor unit piping examples: Piping arrangement using header HEAD8-371-1G Liquid pipe 90 90 56 56 36 36 36 36 Gas pipe Piping arrangement using branch pipe kits 56 30 56 36 36 36 112 112 112 . It is imperative the method of installation and the materials used are also to high standards. The supplied branch pipe kits. soft copper coils or half-hard straight lengths. 7 1/2" ø31.4 1" ø50.92 13/8" ø19.58 Furthest indoor unit =>90m ø22.88 5/8" ø34.05 ø22.7 ø19. 24 26 28 30 32 34 36 38 ø15.92 ø15.52 ø12.22 ø28.05 ø34.5 13/4" ø25.22 7/8" ø44.22 ø12.7 Branch pipes 20 22 Pipe sizes applicable to European installations.8 2" Header pipe Horizontally Good Floor DIS-22-1G/DIS-180-1G HEAD6-180-1G No Good Combination outdoor unit manifold Vertically Floor Floor No DIS-371-1G/DIS-540-2G Floor DOS-2A-1G Combination outdoor unit piping examples: Piping arrangement using branch pipe kits Oil equalisation pipe Outdoor unit branch pipe set (DOS-2A-1G) 112 112 90 90 90 140 Outdoor unit 2 units (for 735~1360) HEAD8-540-2G Outdoor unit branch pipe set (DOS-2A-1G) 112 140 Outdoor unit's branching piping Piping arrangement using header Oil equalisation pipe 140 Branch piping set DOS-2A-1G Indoor unit's first branching piping 112 90 90 90 140 140 140 Total capacity of indoor units ~179 180~370 371~539 540~ Branch piping set DIS-22-1G DIS-180-1G DIS-371-1G DIS-540-2G Header set Model HEAD4-22-1G HEAD6-180-1G HEAD8-371-1G HEAD8-540-2G Branches Max 4 branches Max 6 branches Max 8 branches Max 8 branches 31 .8 ø15.05 3/4" ø38.88 ø19.58 ø22.52 3/8" mm inch ø28.refrigerant piping Outdoor unit (HP) Liquid pipe Gas pipe Liquid pipe Gas pipe 8 10 12 14 16 18 Furthest indoor unit =<90m ø9.05 ø28.88 40 42 44 46 48 ø19.58 11/8" 11/4" ø12.22 ø34.1 11/2" ø22.92 mm inch ø9. Separate power supplies should be used for the outdoor unit (3/phase) and the indoor units (1/phase). separate power supply system Earth leakage breaker (Impulse withstanding type) Circuit breaker for cabling Outdoor unit Grounding wire A Power cable (Main Power cable)[4 cores] B Signal wire (Super Link wire)[2 cores] C Power cable (Indoor unit power cable) [2 cores] D Remote control cord A [2 cores] A B B C Circuit breaker for cabling Earth leakage breaker Indoor unit D R R R R R R Remote control unit Indoor unit power supply: Single phase 220V CAUTION If the earth leakage breaker is exclusively for ground fault protection.R410A electrical wiring – power supply KX6 new design includes greatly simplified wiring requirements utilising a ‘polarity-free’ two wire control loop connecting the indoor units. then you will need to install a circuit breaker for wiring work. right. KX6 outdoor unit mechanical compartment Electrical component box Outdoor unit power supply terminal block 32 . Only control wiring is connected from outdoor to indoor unit. Power wiring Cables can be laid through the front. Outdoor unit power supply: 3 phase 4 wiring 380V Distributed. left or bottom of the outdoor unit casing. Connect the signal line between outdoor units on different refrigerant lines to A2 and B2. Important Outdoor unit Outdoor unit Loop wiring prohibited Outdoor unit Outdoor unit Indoor unit Indoor unit Indoor unit Indoor unit Indoor unit Indoor unit Outdoor unit Outdoor unit Outdoor unit The signal lines cannot form a loop. Indoor unit Indoor unit Indoor unit Indoor unit Remote control wiring specifications For interconnecting wiring between the remote control and indoor units (XY wiring) use 2-core cable size 0. The control wiring is 5 Volt DC.25mm2.25mm2 YES NO 3. 2. We recommend the both ends of the shield of the cable are connected to ground (earth) at all the indoor units and outdoor units.25mm2 x 2 core 2. (1) When one outdoor unit is used Outdoor signal line terminal block Indoor signal line terminal block A1 A Indoor and outdoor signal line do not have a polarity. . (b) The signal wires can also be connected using the method shown below. Outdoor unit A B A B Indoor unit Length (m) 100 to 200 To 300 To 400 To 600 Wire size 0.75mm2 or 1. Any of the connections in the following illustration can be made. ~1000m 1000~1500m 0. For current specification of 2-core (AB) wiring. B1 B A B A B A1 A A1 A B1 B B1 B (2) When plural outdoor units are used 4. non-polarised. please consult your MHI dealer.75mm2 x 2 core 1. use the wire size detailed on the table opposite.Connect the signal cable between indoor and outdoor units and the signal cable between outdoor units belonging to the same refrigerant line to A1 and B1. so the wirings shown as in the diagram are prohibited. This wiring must be a 2-core shielded cable size 0. two wire connection notated as ‘A1’ and ‘B1’. Where the 2-core wiring exceeds 100m. 5. . This ‘AB’ wiring connects outdoor unit to indoor unit and indoor unit to indoor unit. (3) The signal lines can also be connected using the method shown below.3mm2.75mm2 YES YES 1. The maximum length of 2-core cable is 600 metres.electrical wiring – control wiring 1. Outdoor unit Outdoor unit Outdoor unit Outdoor unit A1·B1 A2·B2 A1·B1 A2·B2 A1·B1 A2·B2 A1·B1 A2·B2 Indoor unit Indoor unit A B A B Indoor unit Indoor unit A B A B Signal line Network connector Refrigerant pipe (a) The maximum number of indoor units that can be connected in a system is 128 and it is possible to configure outdoor units and/or indoor units as an outdoor or indoor unit group connected with each other with two wires.5mm2 x 2 core 0.0mm2 x 2 core Remote control A Indoor unit B A Indoor unit B A B Indoor unit Wires can be connected across different refrigerant systems when wired within 1 Superlink system 33 . When plural outdoor units are used. and outdoor temp. RC-E5. Air flow: FDT28/36/45/56 20m3/min.03 0. FDT71 46dB(A).08 0.88(5/8") 1.35(1/4") Installation data Refrigerant piping size mm(in) Gas line:ø9. As individual flap control is available even after installation.5 Hi:27 Me:24 Lo:20 Hi:30 Me:27 Lo:23 Possible T-PSA-3BW-E Pocket Plastic net x1 (Washable) wired:RC-EX1A. Sound pressure level indicates the value in an anechoic chamber. FDT56 39dB(A). of 35ºCDB. Individual flaps can be set at different angles. FDT28KXE6F FDT36KXE6F FDT45KXE6F FDT56KXE6F FDT71KXE6F Remote control (option) Wired RC-EX1A RC-E5 RCH-E3 Wireless FDT90KXE6F FDT112KXE6F FDT140KXE6F FDT160KXE6F RCN-T-36W-E Individual flap control system The thinnest design According to room temperature conditions. Shape of Heat exchanger KX6 KX4 270mm 365mm 246 298 mm KX4 mm 9% FDT28~71 FDT112~160 reduction!! KX6 18% reduction!! Flap control system Selection of flap position is possible.5 5.15 65 Hi:40 Me:37 Lo:35 Hi:42 Me:40 Lo:37 Hi:43 Me:41 Lo:38 Unit:298x840x840 Panel:35x950x950 Unit:24 Panel:5.6 4.0 1 Phase 220V. reduction of weight and significant compact design are realized. Due to optimization of outlet design of air flow with our new advanced technology.0 0. for both persons who are feeling hot or cold can cool both the kitchen and the guests Specifications Item Model FDT28KXE6F Nominal cooling capacity kW 2. of 7ºCDB. 6ºCWB.5 16.R410A Indoor units Ceiling Cassette -4wayFDT Model No. Q’ty Remote control(option) Liquid line:ø6. and outdoor temp. Cooling: Indoor temp.0 11.15 0.1 8.3 7. is not applicable to the *RCH-E3 Individual flap control system Upper position Movable range Lower position for person who is far from the indoor unit and the Flap control system. Powerful-Hi can be selected.0 16. installation area became wider than before. of 20ºCDB. RCH-E3 wireless:RCN-T-36W-E Liquid line:ø6.35(1/4") Gas line:ø12.0 Unit:27 Panel:5.52(3/8") Gas line:ø15. the highest energy efficiency level. During operation these values are somewhat higher due to ambient conditions. the height of indoor unit is reduced drastically.03 53 0.8 Nominal heating capacity kW 3.7(1/2") Liquid line:ø9. sufficient air flow is secured and long reach of air flow is realized. four directions of air flow can be controlled by individual flap as preferred.52(3/8") FDT36KXE6F FDT45KXE6F FDT56KXE6F FDT71KXE6F 3. 2. Thanks to new design of heat exchanger changed from 2 parts to 1 part. FDT71 28m3/min.0 18.2 Power source Cooling Power consumption Heating kW Sound power level dB(A) Sound pressure level dB(A) Exterior dimensions mm HxWxD Net weight kg Air flow m3/min Outside air intake Panel Air filter.0 4. 34 .5 FDT90KXE6F FDT112KXE6F FDT140KXE6F FDT160KXE6F 9. FDT90/112/140/160 37m3/min.0 5.0 10.04 60 Hi:33 Me:31 Lo:30 Unit:246x840x840 Panel:35x950x950 Unit:22 Panel:5. Heating: Indoor temp.08 64 0. Sound pressure level: FDT28/36/45 37dB(A). FDT90/112/140/160 51dB(A). The data are measured under the following conditions(ISO-T1).2 12. of 27ºCDB.5 Hi:18 Me:16 Lo:14 14. Furthermore applying DC fan motors to FDT models. 19ºCWB.04 0.6 6. 60Hz 0. Dimensions All measurements in mm. 160KXE6F 35 . 56KXE6F. 36KXE6F. FDT28KXE6F. 140KXE6F. 45KXE6F. 71KXE6F FDT90KXE6F. 112KXE6F. of 7ºCDB.5 1.5 Me:8. installation area became wider than before. The industry's lowest sound pressure level:25dB(A) of FDTC15KXE6F was achieved by Optimizing fan speed and distributor size.5 Lo:7 Hi:10 Me:9 Lo:7 Hi:9. Individual flaps can be set at different angles. of 20ºCDB. . Taking OA (Outside Air) into inside Quiet operation (Sound pressure level in the Lo mode. 2. FDTC56 16m3/min.5 Lo:4.2 2. please refer to our technical manual. and outdoor temp. FDTC15KXE6F FDTC22KXE6F FDTC28KXE6F FDTC36KXE6F FDTC45KXE6F FDTC56KXE6F Remote control (option) NEW Wired Wireless RC-EX1A RC-E5 RCH-E3 RCN-TC-24W-ER (1) Can not be connected to some KX outdoor units.0 4.5 Me:8.6 4.R410A Ceiling Cassette -4way Compact (600x600mm)FDTC Fits into standard 600 x 600 ceiling Model No. (2) Regarding pipe length (150m or more is required) and temperature condition (lowest 10ºC) in the cooling operation etc. . outside air can be taken inside.02 0.5 Lo:4. 19ºCWB.3 to 2. Sound pressure level: FDTC15 34dB(A). Selection of flap position is possible. and outdoor temp.5 Hi:7 Me:5. Using 2 joint ducts: OA from 1.02 0. Please consult your dealer for further details. 36 Powerful-Hi can be selected.52(3/8") Liquid line:ø6.7(1/2") 1.6 6.05 0.5 Lo:8 Hi:10 Me:9 Lo:8 Possible with OA Spacer TC-OAS-E & Joint Duct TC-OAD-E TC-PSA-25W-E Pocket Plastic net x1 (Washable) wired:RC-EX1A.5 Hi:11 Me:9 Lo:7 Hi:11 Me:9 Lo:8 Hi:13 Me:10 Lo:7 Hi:13 Me:10 Lo:8 Unit:248x570x570 Panel:35x700x700 kg Cooling Air flow m3/min Heating Outside air intake Panel Air filter. Heating: Indoor temp.03 0. FDTC22/28 12m3/min.5 Hi:9. FDTC36 46dB(A).2 3. Upper position Movable range Lower position Specifications Model Item Nominal cooling capacity kW Nominal heating capacity kW Power source Cooling Power consumption Heating kW Sound power level dB(A) Sound pressure Cooling dB(A) level Heating FDTC15KXE6F FDTC22KXE6F FDTC28KXE6F FDTC36KXE6F FDTC45KXE6F FDTC56KXE6F 1. RCH-E3 wireless:RCN-TC-24W-ER Liquid line:ø6.5 2.5 5. During operation these values are somewhat higher due to ambient conditions. 6ºCWB.03 56 Hi:32 Me:28 Lo:25 Hi:32 Me:28 Lo:25 Hi:35 Me:33 Lo:30 Hi:35 Me:33 Lo:32 Exterior dimensions mm HxWxD Net weight Installation data Refrigerant piping size mm(in) Hi:40 Me:37 Lo:31 Hi:40 Me:37 Lo:34 Hi:45 Me:39 Lo:31 Hi:45 Me:39 Lo:34 Unit:15 Panel:3. of 27ºCDB. Q’ty Remote control(option) 58 Hi:38 Me:36 Lo:31 Hi:38 Me:36 Lo:34 0. Indoor Unit FDTC 32 30 25 300mm OA Spacer 30 25 dB 25 dB KX6 (Cooling) KX6 (Heating) 20 Ceiling OA surface Panel OA Joint Duct 30 dB 32 dB 25 31 dB 34 dB 20 KX4 KX6 (Cooling/Heating) (Cooling) FDTC15 30 3~8dB Down 25 20 NEW Individual flap control system 32 dB dB 36 dB 34 34 dB dB 34 dB 2dB Down KX6 (Heating) KX4 (Cooling/Heating) KX6 (Cooling) KX6 (Heating) FDTC36/45/56 FDTC22/28 Flap control system According to room temperature conditions. FDTC22/28 44dB(A).05 60 Hi:7 Me:5.3 1 Phase 220. four directions of air flow can be controlled by individual flap as preferred. Sound pressure level indicates the value in an anechoic chamber. FDTC45 48dB(A). The data are measured under the following conditions(ISO-T1). 60Hz 0.6m3/min. FDTC56 49dB(A). is not applicable to the Individual flap * RCH-E3 control system and the Flap control system. (dB)40 (dB)40 (dB)40 35 35 35 39 dB Using 1 joint duct: OA up to 1.3m3/min.35(1/4") Gas line:ø12. RC-E5.) OA Spacer TC-OAS-E (option) Joint Duct TC-OAD-E (option) Utilizing OA spacer which comes as optional equipment.8 3. As individual flap control is available even after installation. of 35ºCDB. FDTC36 13m3/min. Air flow: FDTC15 8m3/min. Cooling: Indoor temp.35(1/4") Gas line:ø9.5 Unit:14 Panel:3. FDTC45 15m3/min.0 5.7 2. 22KXE6F. FDTC15KXE6F.Dimensions All measurements in mm. 28KXE6F Connectable with VP20(Standard) or VP25(used with attached socket) Ultra slim design at just 248mm above the ceiling Condensate drain pump included as standard 37 . and outdoor temp.3 7.09 0.2 4. 6ºCWB.19 0. Heating: Indoor temp. 2. 60Hz 0.5 14.5 5. of 20ºCDB.0 1 Phase 220V. It allows a piping layout with a high degree of freedom depending on the installation location. FDTW90/112/140 48dB(A).7(1/2") TW-PSA-46W-E Pocket Plastic net x3 (Washable) Liquid line:ø9.0 11. Q’ty Remote control(option) Unit:20 Panel:8.14 0. During operation these values are somewhat higher due to ambient conditions.19 Unit:325x1535x620 Panel:20x1835x680 Unit:23 Panel:8. Dirt condition of the bottom of a drain pan can be checked through this transparent access hole without removing drain pan. Cooling: Indoor temp.5m3/min.5 Unit:35 Panel:13 Hi:27 Me:23 Lo:20 Possible TW-PSA-26W-E Pocket Plastic net x2 (Washable) wired:RC-EX1A.R410A Ceiling Cassette -2wayFDTW NEW Model No. Flexible hose 750mm Installation workability Transparent access hole to drain pan Drainage spout Drainage flow test can be done easily by use of this drainage spout. and outdoor temp.0 10. of 27ºCDB.5 Hi:12 Me:10 Lo:9 0.35(1/4") Gas line:ø12. A cross is visible invisible Cleaning Cleaning not required required An outer circle is visible Specifications invisible Item Model Nominal cooling capacity kW Nominal heating capacity kW Power source Cooling Power consumption Heating kW Sound power level dB(A) Sound pressure level dB(A) Exterior dimensions mm HxWxD FDTW28KXE6F FDTW45KXE6F FDTW56KXE6F FDTW71KXE6F FDTW90KXE6F FDTW112KXE6F FDTW140KXE6F 2.0 Net weight kg Air flow m3/min Outside air intake Panel Air filter.88(5/8") 1.6 6. RC-E5. RCH-E3 wireless:RCN-TW-E Liquid line:ø6.5 0. Air flow: FDTW28/45/56/71 14.0 16. of 7ºCDB.0 5. The data are measured under the following conditions(ISO-T1).10 58 Hi:38 Me:34 Lo:31 65 Hi:45 Me:41 Lo:37 Unit:325x820x620 Panel:20x1120x680 Liquid line:ø6. of 35ºCDB. Powerful-Hi can be selected.52(3/8") Unit:21 Panel:8.1 8.2 12. FDTW28KXE6F FDTW45KXE6F FDTW56KXE6F FDTW71KXE6F Remote control (option) Wired FDTW28~71 RC-EX1A RC-E5 RCH-E3 Wireless FDTW90KXE6F FDTW112KXE6F FDTW140KXE6F RCN-TW-E FDTW90~140 750mm Drain Pump Drain can be discharged upward by 750mm from the ceiling surface close to the indoor unit.14 9.8 3. 19ºCWB. FDTW90/112/140 31m3/min.10 0.35(1/4") Installation data Refrigerant piping size mm(in) Gas line:ø9.52(3/8") Gas line:ø15. Sound pressure level: FDTW28/45/56/71 42dB(A).09 0. 38 . Sound pressure level indicates the value in an anechoic chamber. 71KXE6F FDTW90KXE6F. FDTW28KXE6F. 112KXE6F. 56KXE6F. 140KXE6F 39 .Dimensions All measurements in mm. 45KXE6F. and outdoor temp.35(1/4") Gas line:ø9. FDTQ22KXE6F FDTQ28KXE6F FDTQ36KXE6F Remote control (option) Fits into standard 600 x 600 ceiling Wired RC-EX1A RC-E5 RCH-E3 Wireless RCN-KIT3-E Compact design • Comfortable effective cooling for small rooms.4m3/min. Cooling: Indoor temp.8 3. of 20ºCDB. 60Hz Cooling 0.7(1/2") 1.0 Power source 1 Phase 220V. The data are measured under the following conditions(ISO-T1).07 0.5 Unit:23 Panel:3 Unit:23 Panel:2. Sound pressure level indicates the value in an anechoic chamber.2 4. Powerful-Hi can be selected. Air flow: FDTQ22/38/36 8m3/min. 6ºCWB.07 0. Heating: Indoor temp.5 3.2 2.5 Unit:23 Panel:3 Unit:23 Panel:2.07 0. 2. 40 .5 Unit:23 Panel:3 Unit:23 Panel:2. of 27ºCDB.5 Unit:23 Panel:3 Unit:23 Panel:2. 19ºCWB.6 Nominal heating capacity kW 2. Q’ty Pocket Plastic net x1 (Washable) Remote control(option) wired:RC-EX1A. with low fan speed air flow at just 5. of 35ºCDB.07 Sound power level dB(A) 60 Sound pressure level dB(A) Hi:41 Me:38 Lo:33 Hi:41 Me:38 Lo:33 Hi:41 Me:38 Lo:33 Hi:41 Me:38 Lo:33 Hi:41 Me:38 Lo:33 Hi:41 Me:38 Lo:33 250x570x570 250x570x570 250x570x570 Exterior dimensions Unit mm HxWxD 35x625x650 35x780x650 35x625x650 35x780x650 35x625x650 35x780x650 35x625x650 35x780x650 35x625x650 35x780x650 35x625x650 35x780x650 Panel Net weight kg Unit:23 Panel:2.R410A Ceiling Cassette -1way CompactFDTQ Model No.35(1/4") Gas line:ø12.52(3/8") Liquid line:ø6. and outdoor temp.5 Unit:23 Panel:3 Unit:23 Panel:2. RC-E5. Sound pressure level: FDTQ22/38/36 45dB(A). During operation these values are somewhat higher due to ambient conditions. of 7ºCDB.Drain up Holes for tapping screws Ultra slim design at just 250mm above the ceiling Model Item FDTQ22KXE6F FDTQ28KXE6F FDTQ36KXE6F Direct blow panel Duct panel Direct blow panel Duct panel Direct blow panel Duct panel Panel Name Panel mode (Option) TQ-PSA-15W-E TQ-PSB-15W-E QR-PNA-14W-ER QR-PNB-14W-ER TQ-PSA-15W-E TQ-PSB-15W-E QR-PNA-14W-ER QR-PNB-14W-ER TQ-PSA-15W-E TQ-PSB-15W-E QR-PNA-14W-ER QR-PNB-14W-ER Nominal cooling capacity kW 2.07 0.5 Unit:23 Panel:3 Air flow Hi:7 Me:6 Lo:5 Hi:7 Me:6 Lo:5 Hi:7 Me:6 Lo:5 Hi:7 Me:6 Lo:5 Hi:7 Me:6 Lo:5 Hi:7 Me:6 Lo:5 m3/min Outside air intake Possible Air filter. Optional wide panel shown for solid ceiling Specifications Condensate drain pump included as standard 35 63 285 Fresh air opening for ducting (Knock out) 250 295~325 210 600 or less Max.07 Power consumption Heating kW 0. RCH-E3 wireless:RCN-KIT3-E Installation data Refrigerant piping size mm(in) Liquid line:ø6. Dimensions All measurements in mm. Direct blow panel (TQ-PSA-15W-E) Direct blow panel (TQ-PSB-15W-E) Duct panel (QR-PNA-14W-ER) Duct panel (QR-PNB-14W-ER) * Dimension Table model Unit:mm a b c d TQ-PSA-15W-E 625 514 650 580 TQ-PSB-15W-E 780 514 650 580 Dimension Table model Unit:mm a b c QR-PNA-14W-ER 625 650 580 QR-PNB-14W-ER 780 650 580 41 . 200 x 600 ceiling and Panel size (1. FDTS71 49dB(A). 19ºCWB.09 61 Hi:46 Me:41 Lo:36 Unit:220x1150x565 Panel:35x1250x650 Net weight kg Air flow m3/min Outside air intake Panel Air filter. Air flow: FDTS45 13m3/min. 42 . and outdoor temp. of 27ºCDB. Sound pressure level: FDTS45 42dB(A).5 Installation data Refrigerant piping size mm(in) Liquid line:ø6.R410A Ceiling Cassette -1wayFDTS NEW Model No.5 5.250 x 650) is suitable for 1. Cooling: Indoor temp. and outdoor temp. 2.35(1/4") Gas line:ø12.150 x D:565) brings easy installation for 1.5 Possible TS-PSA-3AW-E Pocket Plastic net x2 (Washable) wired:RC-EX1A. Remote control (option) Wired RC-EX1A RC-E5 RCH-E3 FDTS45KXE6F FDTS71KXE6F Wireless RCN-TS-E 600mm Drain Pump Compact design Drain can be discharged upward by 600mm from the ceiling surface close to the indoor unit. of 7ºCDB. 60Hz 0.0 1 Phase 220V. Powerful-Hi can be selected. Q’ty Remote control(option) Unit:27 Panel:5 Hi:12 Me:11 Lo:9. Heating: Indoor temp. Sound pressure level indicates the value in an anechoic chamber. FDTS71 17m3/min. RC-E5.04 0. of 20ºCDB. The data are measured under the following conditions(ISO-T1). During operation these values are somewhat higher due to ambient conditions.88(5/8") 1.1 8.7(1/2") Unit:28 Panel:5 Hi:15 Me:12 Lo:9. of 35ºCDB.09 0.52(3/8") Gas line:ø15. Indoor unit size (W:1.200 x 600 ceiling. RCH-E3 wireless:RCN-TS-E Liquid line:ø9.04 60 Hi:40 Me:38 Lo:35 0. 6ºCWB. Height is the industry's lowest height level 220mm and weight is 27/28kg only. Flexible hose 600mm 220mm Specifications Item Model Nominal cooling capacity kW Nominal heating capacity kW Power source Cooling Power consumption Heating kW Sound power level dB(A) Sound pressure level dB(A) Exterior dimensions mm HxWxD FDTS45KXE6F FDTS71KXE6F 4. It allows a piping layout with a high degree of freedom depending on the installation location.0 7. 43 .Dimensions All measurements in mm. Indoor unit will control fan-speed to keep rated air flow volume at each fan speed setting.P. E.1 8. and outdoor temp. FDU140 39m3/min. No. FDU112 36m3/min.35 0. FDU112 44dB(A). 80Pa 90Pa 100Pa 110Pa 120Pa 130Pa 140Pa 150Pa *Range of 80~150 Pa is set at ex-factory default.P.P. FDU71/90 38dB(A).24 0.9 No.S.S.2 12.0 1 Phase 220.P.52(3/8") Gas line:ø15.15 E. of 20ºCDB.S. NEW FDU45KXE6F Remote control (option) Wired FDU56KXE6F FDU71KXE6F FDU90KXE6F FDU112KXE6F FDU140KXE6F FDU160KXE6F RC-EX1A RC-E5 RCH-E3 Wireless RCN-KIT3-E Automatic external Static Pressure(E.6 6. 19ºCWB.88(5/8") 1. 44 . Heating: Indoor temp.R410A Duct Connected -High Static PressureFDU Model No.P.0 10.0 5.0 18. FDU71/90 24m3/min.10 No.10 60 Hi:32 Me:29 Lo:26 0.35(1/4") Gas line:ø12.3 7.FDU160 47dB(A).42 0. Cooling: Indoor temp.0 16.13 No. by wired remote control that calculated with the set air flow rate and pressure loss of the duct connected. 6ºCWB.24 65 Hi:33 Me:29 Lo:25 280x750x635 280x950x635 29 Hi:10 Me:9 Lo:8 34 Hi:19 Me:15 Lo:10 280x1370x740 Hi:28 Me:25 Lo:19 54 Hi:32 Me:26 Lo:20 Hi:35 Me:28 Lo:22 200 Possible Procure locally wired:RC-EX1A.10 0.S. New FDU Duct Duct Longer Duct Ceiling Keep the same air flow volume case1 RC-E5 case2 Setting No.0 9. The data are measured under the following conditions(ISO-T1).S. Sound pressure level: FDU45/56 37dB(A).) can be set by E. button.14 No.S. <Expansion of external static pressure range> Current New 10~130Pa 10~200Pa Specifications Model Item Nominal cooling capacity kW Nominal heating capacity kW Power source Cooling Power consumption Heating kW Sound power level dB(A) Sound pressure level dB(A) Exterior dimensions mm HxWxD Net weight kg Air flow (Standard) m3/min Maximum external static pressure Pa Outside air intake Air filter Remote control(option) Installation data Refrigerant piping size mm(in) FDU45KXE6F FDU56KXE6F FDU71KXE6F FDU90KXE6F FDU112KXE6F FDU140KXE6F FDU160KXE6F 4. Range of 10~200 Pa is available by setting SW8-4 switch on at site. of 7ºCDB.7(1/2") Liquid line:ø9. of 27ºCDB. RC-E5. External static pressure of indoor unit is 60Pa. 2.S.5 14.42 Hi:38 Me:36 Lo:30 Hi:40 Me:34 Lo:29 Hi:40 Me:35 Lo:30 0.0 16.P.8 No.0 0. and outdoor temp.32 0.35 0.31 0.) by method of manual setting on remote control. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions. button External Static Pressure (E.12 No. Powerful-Hi can be selected. You can set required E.P) control You can set External Static Pressure (E. 60Hz 11. FDU160 48m3/min.11 No. Air flow: FDU45/56 13m3/min.5 5. FDU140 45dB(A). of 35ºCDB. RCH-E3 wireless:RCN-KIT3-E Liquid line:ø6. 56KXE6F FDU71KXE6F.Dimensions All measurements in mm. FDU45KXE6F. 90KXE6F FDU112KXE6F. 140KXE6F. 160KXE6F 45 . External static pressure of indoor unit is 100Pa. FDU224KXE6F FDU280KXE6F Remote control (option) Wired RC-EX1A RC-E5 RCH-E3 Wireless RCN-KIT3-E Fan control kit (option) (100~200Pa) U-FCRA Adaptability to higher static pressures High static pressure of 200Pa Control box Slide type fan system Thin type duct connection opening Fan motor High static pressure silent fan Specifications Model Item Nominal cooling capacity kW Nominal heating capacity kW Power source Cooling Power consumption Heating kW Sound power level dB(A) Sound pressure level dB(A) Exterior dimensions mm HxWxD Net weight kg Air flow (Standard) m3/min Maximum external static pressure Pa Outside air intake Air filter Remote control(option) Installation data Refrigerant piping size mm(in) FDU224KXE6F FDU280KXE6F 22. and outdoor temp. 46 . 2. of 35ºCDB. 19ºCWB.52(3/8") Gas line:ø22. 4. RCH-E3 wireless:RCN-KIT3-E Liquid line:ø9. and outdoor temp.R410A Duct Connected -High Static PressureFDU Model No. Heating: Indoor temp. 60Hz 1. 6ºCWB. when external static pressure is 200Pa (factory setting).22(7/8") 1. Values of air flow volume are those at external static pressure 200Pa (factory setting). Sound pressure level indicates the value in an anechoic chamber. of 7ºCDB.5 1 Phase 220V. of 27ºCDB.46 1.28 1. During operation these values are somewhat higher due to ambient conditions.0 31. of 20ºCDB. Values of sound pressure level become increased 5dB(A).48 1.52(3/8") Gas line:ø19. Cooling: Indoor temp.36 Hi:51 Hi:52 360x1570x830 92 Hi:51 Hi:68 200 Possible(on Return duct) Procure locally wired:RC-EX1A. 3.0 28.05(3/4") Liquid line:ø9.4 25. RC-E5. The data are measured under the following conditions(ISO-T1). VIEW VIEW A A 47 .Dimensions All measurements in mm. 90 UM-FL3EF : for 112. of 27ºCDB. During operation these values are somewhat higher due to ambient conditions. FDUM140 45dB(A). 60Hz Cooling 0.0 12.0 5. Powerful-Hi can be selected.6 7. Air flow: FDUM22/28/36/45/56 13m3/min.8 3. Maintenance can be available from the right side or the bottom side.52(3/8") Liquid line:ø6. 2.45 Sound power level dB(A) 60 65 Hi:32 Me:29 Lo:26 Hi:38 Me:36 Lo:30 Hi:40 Me:34 Lo:29 Hi:40 Me:35 Lo:30 Sound pressure level dB(A) Hi:33 Me:29 Lo:25 Exterior dimensions 280 x 750 x 635 280 x 950 x 635 280 x 1370 x 740 mm HxWxD Net weight Air flow Maximum external static pressure 29 Hi:10 Me:9 Lo:8 kg m3/min 34 Hi:19 Me:15 Lo:10 100 Pa Outside air intake Air filter Remote control(option) Installation data Refrigerant piping size mm(in) 54 Hi:28 Me:25 Lo:19 Hi:32 Me:26 Lo:20 Hi:35 Me:28 Lo:22 Possible Filter kit:UM-FL1EF/UM-FL2EF/UM-FL3EF(option) wired:RC-EX1A.0 10. and outdoor temp.29 0. 160 RC-EX1A *Filter pressure loss:5pa RC-E5 RCH-E3 Improvement of the serviceability Thin design Fan unit (impeller and motor) can be pulled out from the right side or the bottom side of the unit. 48 .0 16.6 4. FDUM160 47dB(A).33 0. EW N FDUM71KXE6F FDUM22KXE6F FDUM90KXE6F FDUM112KXE6F FDUM140KXE6F FDUM160KXE6F FDUM28KXE6F FDUM36KXE6F FDUM45KXE6F FDUM56KXE6F Remote control (option) Wired Filter kit (option) Wireless UM-FL1EF : for 22~56 UM-FL2EF : for 71.0 Nominal heating capacity kW 2. of 35ºCDB. of 20ºCDB. External static pressure of indoor unit is 35Pa(22/28/36/45/56/71/90). of 7ºCDB. Cooling: Indoor temp.3 8.5 3.5 5. RCN-KIT3-E 70mm less H 350 Pipe H 280 Fan unit Unit FDUM112/140KXE6F Maintenance hole 19mm less Service space H 299 H 280 (mm) FDUM22~90KXE6F Specifications Model FDUM22KXE6F FDUM28KXE6F FDUM36KXE6F FDUM45KXE6F FDUM56KXE6F FDUM71KXE6F FDUM90KXE6F FDUM112KXE6F FDUM140KXE6F FDUM160KXE6F Item Nominal cooling capacity kW 2. 140.2 14. FDUM160 48m3/min.5 16. FDUM71/90 38dB(A).2 2.0 18.0 6. 6ºCWB. Sound pressure level indicates the value in an anechoic chamber. 60Pa(112/140/160). and outdoor temp. RC-E5.45 Power consumption Heating kW 0. FDUM112 36m3/min. FDUM140 39m3/min. FDUM71/90 24m3/min.10 0.33 0.7(1/2") Liquid line:ø9.52(3/8") Gas line:ø15.35(1/4") Gas line:ø12.2 4. Sound pressure level: FDUM22/28/36/45/56 37dB(A).1 9. The height of all FDUM models is only 280mm.29 0. Heating: Indoor temp.10 0. The data are measured under the following conditions(ISO-T1).20 0.0 Power source 1 Phase 220V. 19ºCWB. RCH-E3 wireless:RCN-KIT3-E Liquid line:ø6.0 11.35(1/4") Gas line:ø9.R410A Duct Connected -Low/Middle Static PressureFDUM Model No.88(5/8") 1.20 0. FDUM112 44dB(A). FDUM22KXE6F. 36KXE6F. 140KXE6F. Company e-mail tel AIRZONE jmoral@altracorporacion. 160KXE6F Round duct adapter In case of requirements of round duct adapter. 90KXE6F FDUM112KXE6F. 56KXE6F FDUM71KXE6F. 28KXE6F.es +34-902-400-445 49 . 45KXE6F.Dimensions All measurements in mm. please access the followings for details. RCH-E3 wireless:RCN-KIT3-E Liquid line:ø6.0 0.0 5. .7 Power source Cooling 0. 6ºCWB.09 Hi:7.1 8. The sound level indicates the value of rear-intake type with duct in anechoic chamber. Max:50 Not possible Filter set:UT-FL1EF/UT-FL2EF/UT-FL3EF(option) wired:RC-EX1A. Heating: Indoor temp.09 0.35(1/4") Gas line:ø12. please refer to our technical manual. of 27ºCDB. 60Hz 4. Duct kit and filter options Item Contents for FDUT15/22/28/36KXE6F-E for FDUT45/56KXE6F-E for FDUT71KXE6F-E 1 UT-SAT1EF UT-SAT2EF UT-SAT3EF 2+3 UT-FL1EF UT-FL2EF UT-FL3EF Outlet duct plate Filter set Filter pressure loss : 5 Pa 2 Filter fixing plate 1 Outlet duct plate 3 Filter Specifications Item Model FDUT15KXE6F-E Nominal cooling capacity kW 1.5m below unit.5 Me:9 Lo:7.5 Nominal heating capacity kW 1.35(1/4") Gas line:ø9.06 Sound power level dB(A) Sound pressure level 1 dB(A) Hi:28 Me:26 Lo:22 Sound pressure level 2 dB(A) Hi:32 Me:29 Lo:25 Exterior dimensions mm HxWxD Net weight kg Air flow (Standard) m3/min External Static pressure Pa Outside air intake Air filter Remote control(option) Installation data Refrigerant piping size mm(in) FDUT22KXE6F-E FDUT28KXE6F-E FDUT36KXE6F-E FDUT45KXE6F-E FDUT56KXE6F-E FDUT71KXE6F-E 2.2 Standard:10. RC-E5. (2) Regarding pipe length (150m or more is required) and temperature condition (the lowest is 10ºC) in the cooling operation etc.52(3/8") Liquid line:ø6.0 7. 19ºCWB.6 6.06 Power consumption Heating kW 0. External static pressure of indoor unit is 10Pa. Please consult your dealer for further details.5 Hi:11. The data of nominal cooling and heating capacity and sound pressure level are measured with 10Pa of external static pressure.5 5. The data are measured under the following conditions(ISO-T1).2 2.0 1 Phase 220V. and outdoor temp.5 0.5 2.52(3/8") Gas line:ø15. Sound pressure levels are values when 2m supply duct and 1m return duct are connected.5 Me:9 Lo:7 Hi:12.6 4.8 3.08 0. Max:35 22 Hi:8.07 0.7(1/2") Liquid line:ø9.5 Me:6 Lo:5 Standard:10.5 Me:7 Lo:5. 2 : Mike position is 1m in front and 1m below the air supply duct.08 52 Hi:28 Me:26 Lo:22 Hi:32 Me:29 Lo:26 57 Hi:33 Me:30 Lo:26 Hi:37 Me:34 Lo:28 58 Hi:34 Me:32 Lo:28 Hi:36 Me:33 Lo:27 200x750x500 21 Hi:6 Me:5 Lo:4 0.07 59 Hi:35 Me:33 Lo:30 Hi:38 Me:33 Lo:29 Hi:35 Me:31 Lo:28 Hi:41 Me:37 Lo:32 200x950x500 220x1150x565 25 31 Hi:16 Me:13 Lo:9.88(5/8") 1.R410A Duct Connected (thin) -Low Static PressureFDUT Model No.2 3. of 7ºCDB. of 20ºCDB. NEW FDUT15KXE6F-E Remote control (option) Wired FDUT22KXE6F-E FDUT28KXE6F-E FDUT36KXE6F-E FDUT45KXE6F-E FDUT56KXE6F-E FDUT71KXE6F-E RC-EX1A RC-E5 RCH-E3 Wireless RCN-KIT3-E Expansion of lineup 15KXE6F-E 22KXE6F-E 28KXE6F-E 36KXE6F-E 45KXE6F-E 56KXE6F-E 71KXE6F-E Current * New * (1) Can not be connected to some KX outdoor units. 4. 1 : Mike position is 1. 2. 3. 50 . and outdoor temp. During operation these values are somewhat higher due to ambient conditions. of 35ºCDB. Cooling: Indoor temp. 36KXE6F-E FDUT45KXE6F-E. 28KXE6F-E.Dimensions All measurements in mm. 22KXE6F-E. FDUT15KXE6F-E. 56KXE6F-E FDUT71KXE6F-E 51 . 0 Liquid line:ø6. Powerful-Hi can be selected. and outdoor temp. of 7ºCDB. FDUH22KXE6F FDUH28KXE6F FDUH36KXE6F RC-E5 RCH-E3 Wireless Drain up kit (option) (600mm) UH-DU-E RCN-KIT3-E Filter kit (option) UH-FL1E *Filter pressure loss:5pa Compact and thin size.R410A Duct Connected (Compact & Flexible) FDUH Remote control (option) Wired RC-EX1A Model No. mode. of 35ºCDB. light weight Quiet operation Our leading high technology has realized the best solution for air conditioning in hotels with compact and thin size units and high energy efficiency. 570mm The lowest sound level in the industry can ensure comfortable stay and rest in hotels. of 20ºCDB.8 3. During operation these values are somewhat higher due to ambient conditions.07 60 HI: 33 Me: 30 Lo: 27 257x570x530 22 HI: 7 Me: 6. FDUH22KXE6F 2.2 1 Phase 220V. Sound pressure level: FDUH22/28/36 39dB(A). Cooling: Indoor temp. of 27ºCDB. Sound pressure level indicates the value in an anechoic chamber. 60Hz 0. 19ºCWB.5m3/min.35(1/4") Gas line:ø12.52(3/8") FDUH36KXE6F 3. 257 mm 530m m Installation Flexibility Control box and drain piping can be installed on both side of the unit and air intake to the unit is available from bottom or back side. In addition.07 0. control buttons are limited only to minimum required functions such as ON/OFF. Heating: Indoor temp.7(1/2") 1. Air flow: FDUH22/28/36 8. 6ºCWB. The data are measured under the following conditions(ISO-T1). 52 . Our highest technology can satisfy diverse installation requirements. and outdoor temp.35(1/4") Gas line:ø9. RC-E5.2 2.6 4.5 FDUH28KXE6F 2. 2.5 Lo: 6 30 Not possible Filter kit:UH-FL1E(option) wired:RC-EX1A. temperature setting and fan speed. Wired remote control Simple remote control Control box RCH-E3 (option) Drain piping Specifications Item Model Nominal cooling capacity kW Nominal heating capacity kW Power source Cooling Power consumption Heating kW Sound power level dB(A) Sound pressure level dB(A) Exterior dimensions HxWxD mm Net weight kg Air flow m3/min External static pressure Pa Outside air intake Air filter Remote control(option) Installation data mm(in) Refrigerant piping size Considering specialized usage in hotel rooms. It is really simple and easy to use. weight is only 20kg. RCH-E3 wireless:RCN-KIT3-E Liquid line:ø6. 5 70 15 View G (After bottom plate is replaced to back side) 53 .6 Holes for tapping screws 150 150 494 150 32 27.6 188.5 100 145 30.35 (1/4") (Flare) FDUH36KXE6F ø12.2 150 100 E 549.5 150 198.2 12-ø4 Holes for tapping screws D 890 600 21 68 150 494.2 574 150 32 27.52 (3/8") (Flare) ø6.2 (Suspension bolts pitch) Space for installation and service 255.5 Unit:mm 160 200 Air inlet 38. ( 2 ) When control box is located on the reverse side.3 C1 145.D.5 610 66 37.4 66 95.3 32 27.8 30 32 27. 32.2 Simple remote control 50.5 30 28.6 30 18.26) ø30 (M10) (635X890) Note (3) (Duct dimension) 575.1 Control box Note(4) (Suspension bolts pitch) 156.8 Drain hose piece (Standard Accessory) (Installed on site) Note(4) Notes ( 1 ) The model name label is attached on the fan case inside the air return grille.28KXE6F ø9.C2 D E F (Duct dimension) 12-ø4 32.2 50.5 83.3 Air inlet (D) C2 530 488 62. G Bottom plate (Able to be located on the back side) View G In case of Bottom air intake 150 150 30 12-ø4 Holes for tapping screws Air inlet 160 120 537.Dimensions All measurements in mm.5 28.8 53 Supply air duct Content Model Gas piping Liquid piping Drain piping Hole for wiring Suspension bolts Inspection hole FDUH22KXE6F.6 Symbol A B C1.7 (1/2") (Flare) VP20(O.5 148.8 40 21 273 66. Installation space should be modified to new location.6 Air outlet 30. ( 3 ) Contorl box and Drain hose piece are able to be relocated on the reverse side.8 A B F 30. 2 3. Upper position *RCH-E3 is not applicable to the Flap control system. of 27ºCDB.52(3/8") Hi:47 Me:43 Lo:39 Hi:47 Me:43 Lo:39 Liquid line:ø6. and outdoor temp. Sound pressure level indicates the value in an anechoic chamber.04 57 Hi:35 Me:33 Lo:31 Hi:35 Me:33 Lo:31 Hi:41 Me:35 Lo:31 Hi:39 Me:35 Lo:31 Exterior dimensions mm HxWxD Net weight kg Air flow m3/min Outside air intake Air filter. FDK56 16m3/min.09 Hi:46 Me:42 Lo:37 Hi:46 Me:42 Lo:37 298 x 840 x 259 318 x 1098 x 248 12 Hi:8 Me:7 Lo:6 12. FDK71 24m3/min. Heating: Indoor temp. Flap control system Selection of flap position is possible.1 8.88(5/8") 1. Air flow: FDK22/28 11m3/min. FDK22KXE6F FDK28KXE6F FDK36KXE6F FDK45KXE6F FDK56KXE6F FDK71KXE6F RC-EX1A FDK22~56 RC-E5 RCH-E3 Wireless RCN-K-E : FDK22~56 RCN-K71-E : FDK71 FDK71 Installation Workability Innovative Design New FDK models adopt the air flow design that's proven to minimise resistance in a CFD analysis to achieve uniform air conditioning to the furthest corners of the room.5 2.8 3. Q’ty Remote control(option) Installation data Refrigerant piping size mm(in) 0.R410A Wall Mounted FDK Remote control (option) Wired Model No. 2. FDK45 48dB(A)(Cooling)&43dB(A)(Heating). and outdoor temp. 259 Fast Improved Maintainability Slow Colors in the figure show the air speed. A flap can be set at different angles.0 4.7(1/2") 15.5 5. The new slimmer design allows easy & neat installation even in tight spaces.0 1 Phase 220V.35(1/4") Gas line:ø9. Sound pressure level: FDK22/28 38dB(A). FDK36/45 15m3/min. Cooling: Indoor temp.52(3/8") Gas line:ø15.5 Hi:21 Me:18 Lo:15 Liquid line:ø9. FDK36 48dB(A)(Cooling)&42dB(A)(Heating). Movable range Lower position Specifications Model Item Nominal cooling capacity kW Nominal heating capacity kW Power source Cooling Power consumption Heating kW Sound power level dB(A) Sound pressure Cooling dB(A) level Heating FDK22KXE6F FDK28KXE6F FDK36KXE6F FDK45KXE6F FDK56KXE6F FDK71KXE6F 2. of 7ºCDB.05 0.6 6. RCH-E3 wireless:RCN-K-E (for FDK22~56). Also included is a new easy clean mechanism where the front panel is opened/closed simply from the bottom to easily access the detachable filters. 6ºCWB. 60Hz 0. of 20ºCDB.05 60 Hi:42 Me:37 Lo:33 Hi:42 Me:37 Lo:33 0.3 7.35(1/4") Gas line:ø12. FDK71 48dB(A). 19ºCWB.09 0.05 0. During operation these values are somewhat higher due to ambient conditions. RC-E5. 54 . RCN-K71-E (for FDK71) Liquid line:ø6.0 5. The data are measured under the following conditions(ISO-T1). of 35ºCDB. FDK56 48dB(A)(Cooling)&47dB(A)(Heating).6 4. Powerful-Hi can be selected.2 2.5 13 Hi:10 Me:9 Lo:7 Hi:11 Me:9 Lo:7 Hi:14 Me:12 Lo:10 Not possible Polypropylene net x2 (Washable) wired:RC-EX1A. FDK22KXE6F. 45KXE6F.Dimensions All measurements in mm. 56KXE6F FDK71KXE6F 55 . 36KXE6F. 28KXE6F. 0 0.5 5.20 0. up. FDE71 18m3/min. allowing free layout to meet installation conditions. Heating: Indoor temp.52(3/8") Gas line:ø15. Cooling: Indoor temp.5 14. Specifications Model Item Nominal cooling capacity kW Nominal heating capacity kW Power source Cooling Power consumption Heating kW Sound power level dB(A) Sound pressure level dB(A) Exterior dimensions mm HxWxD FDE36KXE6F FDE45KXE6F FDE56KXE6F FDE71KXE6F FDE112KXE6F FDE140KXE6F 3. FDE71 50dB(A). Q’ty Remote control(option) 28 Hi:10 Me:9 Lo:7 Installation data Refrigerant piping size mm(in) Liquid line:ø6.6 4. of 20ºCDB. RCH-E3 wireless:RCN-E-E Hi:44 Me:41 Lo:39 Hi:46 Me:44 Lo:43 250 x 1620 x 690 49 Hi:26 Me:23 Lo:21 Hi:29 Me:26 Lo:23 Liquid line:ø9.10 62 Hi:41 Me:39 Lo:37 0. Upper position 210mm Movable range is not applicable to *RCH-E3 the Flap control system. right) & drain piping in left or right directions. FDE112 46dB(A).6 6. Powerful-Hi can be selected. Sound pressure level: FDE36/45/56 46dB(A). Lower position Slim and sleek design starting at just 28kgs in weight means quick. A flap can be set at different angles.15 0.1 8.7(1/2") 37 Hi:16 Me:14 Lo:12 Not possible Pocket Plastic net x2 (Washable) wired:RC-EX1A. and outdoor temp. 56 .88(5/8") 1.0 5. and outdoor temp.2 12. Air flow: FDE36/45/56 11m3/min. 19ºCWB.18 210 x 1070 x 690 210 x 1320 x 690 1 Phase 220V. FDE140 32m3/min.0 11. During operation these values are somewhat higher due to ambient conditions. Installation Workability Up Rear Right Refrigerant piping can be routed in three directions (rear.0 4. Sound pressure level indicates the value in an anechoic chamber.16 0.3 7. 60Hz Net weight kg Air flow m3/min Outside air intake Air filter.06 60 Hi:39 Me:38 Lo:36 0. 6ºCWB. 2. RC-E5. FDE36KXE6F FDE45KXE6F FDE56KXE6F FDE71KXE6F FDE112KXE6F FDE140KXE6F RC-EX1A RC-E5 RCH-E3 Wireless RCN-E-E • Small • Light-weight • Quiet • Sleek.0 16. The data are measured under the following conditions(ISO-T1). of 27ºCDB.06 0.R410A Ceiling Suspended FDE Remote control (option) Wired Model No.11 0. intelligent design New Slim Design Flap control system Selection of flap position is possible.35(1/4") Gas line:ø12. FDE140 50dB(A). of 7ºCDB. easy & neat installation. of 35ºCDB. FDE112 28m3/min. 45KXE6F.52 (3/8") (Flare) VP20 (O.C2 E Remove the cutout using side cutter or similar tool. Note(1)The model name label is attached on the fan casing inside the air return grille.D. 140KXE6F 24 19 Right side cutout 5 or more 27 76 300 or more 308 C2 75 12 F 150 or more ø15. B A 31 135 24 27 1022 (Suspension bolts pitch) 5 24 290 (Suspension bolts pitch) 40 FDE36KXE6F. Note(1)The model name label is attached on the fan casing inside the air return grille.7 (1/2") (Flare) ø6.2 D E F G 27 108 215 40 53 109 1240 210 173 271 Space for installation and service 175 0 A C1 Air return grille 110 B Obstacle 135 G Remove the cutout using side cutter or similar tool. B A 31 410 68 690 1620 195 235 Air supply 271 C .26) (M10 or M8) PE cover Plate cover (Knock out) Position of top cutout and back cutout 20 100 or more 27 135 24 40 1572 (Suspension bolts pitch) 10 C1.3m) (Installed on site) 235 Air supply Symbol A B C 1.D.D.C2 235 Air supply 7 100 Drain hose piece (Accessory.35 (1/4") (Flare) VP20 (O.C 15 20 60 7 100 1 2 Drain hose piece (Accessory. 24 145 68 52 53 690 1320 195 60 15 20 C .C2 D 290 (Suspension bolts pitch) 173 40 Hole for drain piping (for left) E Make a space of 4500 or more between the units when installing more than one.3m) (Installed on site) Space for installation and service 76 Air return grille A C1 110 135 B 300 or more 308 C2 75 Symbol A B C1.Dimensions All measurements in mm.C2 5 or more Obstacle Make a space of 5000 or more between the units when installing more than one.26) (M10 or M8) PE cover Plate cover (Knock out) Position of top cutout and back cutout 20 100 or more Content Gas piping Liquid piping Drain piping Hole for suspension bolt Back cutout Top cutout Hole for drain piping(for left back) 53 40 Note)The slope of drain piping inside the unit must take decline of 10mm. Note(1)The model name label is attached on the fan casing inside the air return grille.52 (3/8") (Flare) VP20 (O. 145 52 40 108 53 109 250 255 5 1540 Note) The slope of drain piping inside the unit must take decline of 10mm. 0. Right side cutout Hole for drain piping (for left) G E Remove the cutout using side cutter or similar tool. 57 . Make a space of 4000 or more between the units when installing more than one.88 (5/8") (Flare) ø9. 0. FDE112KXE6F.3m) (Installed on site) 271 Space for installation and service 76 A C1 Air return grille 75 B 110 150 or more 19 ø12. B A 5 1272 (Suspension bolts pitch) 410 31 135 40 24 D 290 (Suspension bolts pitch) 27 FDE71KXE6F 10 C1.88 (5/8") (Flare) ø9.26) (M10 or M8) PE cover Plate cover (Knock out) Hole for drain piping (for left) G Right side cutout 5 or more Obstacle 135 175 0 F 300 or more 308 C2 Content Gas piping Liquid piping Drain piping Hole for suspension bolt Back cutout Top cutout Hole for drain piping (for left back) Position of top cutout and back cutout 12 20 100 or more Symbol A B C 1.C 7 100 1 2 Drain hose piece (Accessory.2 D E F G Content Gas piping Liquid piping Drain piping Hole for suspension bolt Back cutout Top cutout Hole for drain piping (for left back) 0 12 175 19 F 150 or more ø15.2 D E F G 27 108 40 53 109 990 215 210 173 40 Note) The slope of drain piping inside the unit must take decline of 10mm. 10 D 145 410 68 52 690 1070 195 60 15 20 C1. 56KXE6F 53 C1. 0. 0 1 Phase 220V.5 5. of 35ºCDB.02 0.8 3. Simultaneous lower and upper air outlets or upper outlet can be selected by air flow direction button. the sound level has been minimized. Upper position Movable range is not applicable to *RCH-E3 the Flap control system.02 55 Hi:36 Me:34 Lo:30 0. of 20ºCDB. floor standing or behind gallery installation is available. Convenient to use operation Selection of flap position is possible. RCH-E3 wireless:RCN-FW-E Liquid line:ø6. and outdoor temp. the new series fit in various kinds of rooms and create relaxing atmosphere. Heating: Indoor temp. Cooling: Indoor temp.35(1/4") Gas line:ø12. The level of FDFW28KXE6F in the cooling lo mode is 30dB(A) only. 2. Further control can be arranged by a remote control. Q’ty Remote control(option) 19 Installation data Refrigerant piping size mm(in) Liquid line:ø6. of 7ºCDB. RC-E5. Flap control system Thanks to optimum balance of air outlet direction and sufficient air flow volume. 58 . The data are measured under the following conditions(ISO-T1). During operation these values are somewhat higher due to ambient conditions.7(1/2") 1. Lower position (In case of use of wireless remote control) Specifications Model Item Nominal cooling capacity kW Nominal heating capacity kW Power source Cooling Power consumption Heating kW Sound power level dB(A) Sound pressure level dB(A) Exterior dimensions mm HxWxD FDFW28KXE6F FDFW45KXE6F FDFW56KXE6F 2. 60Hz 0.35(1/4") Gas line:ø9. 19ºCWB.3 0.03 60 Hi:44 Me:37 Lo:33 600x860x238 Net weight kg Air flow (Standard) m3/min Air filter.02 0. of 27ºCDB. 6ºCWB.2 4. A flap can be set at different angles.R410A Floor Standing -2wayFDFW Model No.52(3/8") 20 Hi:9 Me:8 Lo:7 Hi:11 Me:9 Lo:8 Polypropylene net x1 (Washable) wired:RC-EX1A. and outdoor temp. Choice of wall hanging. FDFW28KXE6F FDFW45KXE6F FDFW56KXE6F Remote control (option) Wireless Wired RC-EX1A RC-E5 RCH-E3 RCN-FW-E Quiet Operation Sophisticated Design With classy semi flat front panel in chic white.6 6. Sound pressure level indicates the value in an anechoic chamber.02 57 Hi:38 Me:36 Lo:33 5.03 0. Dimensions All measurements in mm. 59 . exhaust air outdoor air supply air outdoor air supply air (1) This unit is the specific unit for processing the outdoor air temperature closer to the room temperature. restroom and kitchen of restaurant etc. (4) Dehumidifying operation with this unit is prohibited. 60 . high static pressure of 200Pa and the industry's lowest noise level can meet various kind of installation location for office. (3) It is strictly prohibited to monitor the room temperature by switching to the thermistor at remote controller side and/or the optional remote thermistor. FDU500FKXE6F FDU850FKXE6F FDU1300FKXE6F FDU1800FKXE6F RC-EX1A RC-E5 RCH-E3 Wireless Fan control kit (option) (100~200Pa) U-FCRB RCN-KIT3-E Air conditioning and intake of outdoor air are in the same system Outdoor Air processing unit can be connected in a KX6 system as one of indoor unit series and can create fresh and comfortable air supply together from our high advanced technology. (2) This unit monitors the outdoor air temperature and controls thermostat ON/OFF at the setting temperature by the remote controller. the operation is changed to the fan mode so that unprocessed outdoor air will be blown into the room directly.R410A Outdoor Air Processing unit FDU-F Remote control (option) Wired Model No. make sure to explain sufficiently about the foregoing cautions. especially in the small room such as a restroom and/or sanitary hot water supplying room. For conditioning the room temperature a dedicated air-conditioner is required additionally. which indicates the outdoor air temperature for controlling thermostat ON/OFF. the installation place and usage of remote control for this unit and the location of the air outlet. Therefore place the air outlet port or orient the air outlet direction not to blow air directly to persons in the room. (5) When handing over this unit to the end user. KX6 outdoor unit indoor unit indoor unit Outdoor Air Processing unit office air conditioning outside air supply corridor refresh room. When thermostat is turned OFF. rest room Compact design Compact design at just 360mm in height. refresh room. Otherwise dew formation at air outlet port and/or dew dripping may occur during cooling operation due to the lower outdoor air temperature. Therefore keep the remote controller of this unit in place closer to the administrator so as not to be touched it freely by the end user. 8 ~ 48 HP : Yes . In case both of OA processing units B and dedicated air-conditioner are connected with KX6 outdoor unit. 4 ~ 6 HP : No Combination with KX6 series case In case OA processing units only Combination The total capacity of FDU-F is 50~100% of outdoor capacity A are connected with KX6 outdoor units and max quantity of FDU-F is 2 units. [A] 10HP [B] FDU850FKXE6F FDU850FKXE6F (5HP) (5HP) Less than 30% 18HP FDU850FKXE6F (5HP) 6HP 6HP Concept FDU-F is air processing unit which can treat the supply air closer to room temperature by cooling or heating in connection with KX6 refrigerant system and exhaust air is discharged to outside of the room. The total capacity of FDU-F and dedicated air-conditioners is 50~100% of outdoor capacity and max quantity of FDU-F should be below 30% of outdoor unit capacity. not connectable to 4~6HP.Connectivity with KX6 series FDU-F series are connectable to 8~48HP KX6 outdoor units. Outside Air Supply Exhaust Air Direct Expansion Heat Exchanger 61 . Temperature range of outdoor air must be 20~40ºCDB (32ºCWB) during cooling and -10~24ºCDB during heating.22(7/8") 1.2 14. Single outdoor air processing unit can be used alone. Q'ty Remote control(option) Air flow (Standard) Liquid line:ø9.13 40 0. Single outdoor air processing unit can be used alone. External static pressure of indoor unit with optional fan controlling kit "U-FCRB" is 100Pa. it usually becomes higher than the displayed value due to the surrounding noise and echo.32 0. when external static pressure is 200Pa (factory setting).5 870 1 Phase 220V. 4. The connection capacity of the outdoor air processing unit must be from 50% to 100% of the total capacity of the outdoor unit.0 4.0 22.R410A Specifications Model Item Nominal cooling capacity kW Nominal heating capacity kW Power source Cooling Power consumption Heating kW Sound pressure level dB(A) Exterior dimension mm HxWxD FDU500FKXE6F FDU850FKXE6F FDU1300FKXE6F FDU1800FKXE6F 9. In case of actual room installation. The total connection capacity of the other standard air conditioning units and the outdoor air processing units must be from 50% to 100% (the total includes the outdoor air processing unit). RCH-E3 wireless:RCN-KIT3-E Liquid line:ø9. 2. The connection capacity of the outdoor air processing unit must not exceed 30% of the capacity of the outdoor unit.05(3/4") Liquid line:ø9. Operation sound is measured in an anechoic room based on JIS standard. 8.52(3/8") Gas line:ø15.0 7. FDU500FKXE6F Control box 12-M5 screw Duct connection port for outdoor air inlet 12-M5 screw Port for air outlet (Below suspension bolt pitch) Above (Inner size of duct flange) Below (Inner size of duct flange) or more Plan view or more or more Installation space Installation space Front view or more Installation space Slab (Service from side) 62 or more Piping space (Service from below) (Service from side and below) or more Ceiling Service space Symbol Content Gas piping Liquid piping Drain piping connection Power supply wiring connection Suspension bolt Inspection Opening Inspection Opening (Inner size of duct flange) (Inner size of duct flange) Suspension bolts pitch Suspension bolts pitch . 5. 7.52(3/8") Gas line:ø19. Dimensions All measurements in mm. 60Hz Net weight kg m3/min m3/h External static pressure Pa Air filter. The data are measured at 33ºCDB 28ºCWB (68%RH) during cooling and 0ºCDB-2. Maximum number of outdoor air processing units that can be connected to the outdoor unit is 2units.5 1290 84 30 1800 200 Procure locally wired:RC-EX1A.4 10.8 0.9 28.38 47 360x820x830 360x1200x830 48 8.32 45 0.0 14.5 510 62 14.9ºCWB (50%RH) during heating (no frost).88(5/8") Installation data mm Refrigerating piping size (in) 360x1570x830 82 21.18 0.38 0. Values of sound pressure level become increased 5dB(A). RC-E5. 3. Values of air flow volume are those at external static pressure 200Pa (factory setting). 6.13 0.52(3/8") Gas line:ø22.18 43 0. FDU1800FKXE6F Content Symbol Slab Service space Port for air outlet 12-M5 screw Above (Below suspension bolt pitch) 16-M5 screw (Inner size of duct flange) (Inner size of duct flange) Suspension bolts pitch Suspension bolts pitch Control box 20-M5 screw Installation space or more Plan view or more Installation space Below (Inner size of duct flange) Front view or more (Inner size of duct flange) or more Symbol Slab Service space (Service from side) or more Piping space (Service from below) (Service from side and below) or more Ceiling Service space Port for air outlet Above (Below suspension bolt pitch) 20-M5 screw Duct connection port for outdoor air inlet (Inner size of duct flange) (Inner size of duct flange) Suspension bolts pitch Suspension bolts pitch Content Gas piping Liquid piping Drain piping connection Power supply wiring connection Suspension bolt Inspection Opening Inspection Opening 63 .FDU850FKXE6F Control box Duct connection port for outdoor air inlet or more or more Plan view Below Installation space or more Installation space (Inner size of duct flange) Front view or more (Inner size of duct flange) Installation space Gas piping Liquid piping Drain piping connection Power supply wiring connection Suspension bolt Inspection Opening Inspection Opening or more Piping space or more Ceiling (Service from side) (Service from side and below) (Service from below) FDU1300FKXE6F. 8m Wireless remote control (option) For wireless control simply insert the infra-red receiver kit on a corner of the panel RCN-T-36W-E. RCN-K71-E wireless remote control is not applicable to the Individual flap control system and the Flap control system. mode. FDUM.R410A Control Systems <Individual control> Remote Control line up indoor unit remote control RC-EX1A wired all models RC-E5 RCH-E3 indoor unit remote control indoor unit FDT RCN-T-36W-E FDTS wireless FDTC RCN-TC-24W-ER FDK22~56 FDTW RCN-TW-E FDK71 remote control indoor unit RCN-TS-E FDE RCN-K-E FDFW RCN-K71-E others* remote control RCN-E-E RCN-FW-E RCN-KIT3-E *FDTQ. temperature setting and fan speed. It is really simple and easy to use. FDUH. you can ensure energy saving air conditioning by avoiding excessive cooling or heating. AUTO restart This function allows starting the air conditioner automatically when power supply is restored after power failure or by turning on the power switch. Room temperature controlled by the remote control sensor The temperature sensor is housed in the top section of the remote control unit. or individual remote control in each room is not required but only sensor is required (as when center control system is in place). *RCH-E3 is not applicable to the Individual flap control system and the Flap control system. *When RCH-E3 is used. FDU-F Wired remote control with weekly timer (option) RC-E5 Run hour meters to facilitate maintenance checking The RC-E5 controller enables extensive access to service and maintenance technical data combined with easy to use functions and a clear LCD display. *The *When the wireless remote control is used. In case sensor in the indoor units or the remote control sensor can not sense the room temperature correctly. It also displays cumulative operation hours of the air conditioner and compressor since commissioning. A user can specify up to four times a day to start/stop the air conditioner. RC-E5 stores operation data when an anomaly occurs and indicates the error on the LCD. This arrangement has improved the sensitivity of the remote control unit’s sensor. which permits more finely controlled air conditioning. Changeable set temperature ranges RC-E5 allows the upper and lower limits of a set temperature range to be specified separately. which allows one-week operation schedules to be registered. (Temperature setting is also possible with the timer). install SCTHB-E3 at proper place in the rooms. FDU. 64 RCN-E-E RCN-FW-E RCN-KIT3-E . FDUT. the fan speed setting can only be set to 3 speed settings (Hi-Me-Lo). Timer operation Changeable range Upper limit 20~30ºC(effective for heating operation) Lower limit 18~26ºC(effective for non-heating operation) Thermistor (option) Simple remote control (option) SC-THB-E3 RCH-E3 (wired) Considering specialized usage in hotel rooms. Up to 16 units It can control up to 16 units individually. RCN-TC-24W-ER RCN-TW-E RCN-TS-E RCN-K-E. with pressing the AIR CON No. Weekly timer function as standard RC-E5 provides (as a standard feature) a weekly timer. By adjusting a set temperature range. button. the fan speed setting can only be set to 3 speed settings (Hi-Me-Lo). control buttons are limited only to minimum required functions such as ON/OFF. while providing complete commissioning and service maintenance assistance for installers and service engineers. All operational functions.network to suit any application large or small.is an advanced high speed data transmission system that can connect up to 128 indoor units and 32 outdoor units as a network.<Control System> SUPERLINKMHI has now combined simplicity of installation with our highly sophisticated Superlink. Superlink. Individual On/Off Control KX6 Outdoor units SC-WGWNA-A/B PC Control Interface Multi-KX6 indoor units KX6 twined Outdoor units Center Control SC-SL4-AE/BE Multi-KX6 indoor units with individual room control Center Control SC-SL1N-E 3-core + earth cable for connecting indoor and outdoor units 3-core cable for connecting indoor and outdoor units 3-core cable for connecting indoor and outdoor units 3-core + earth cable for connecting indoor and outdoor units SRK/SRF-ZJXseries SC-BIKN-E Wireless remote control SC-ADNA-E One-to-one SC-ADNA-E SC-ADNA-E SC-ADNA-E Wireless 65 . non-polar cable .control system.network using SC-ADNA-E. The Superlink. to offer building owners and occupiers a comprehensive control and management system. Individual MHI split systems can also be integrated on to the Superlink. plus enable/disable connected remote control. MHI offers a wide range of control options for the Superlink. Multi-KX6 outdoor units "Micro KX" Multi-KX6 indoor units Center Control SC-SL2NA-E Capable of control and monitoring up to 64 indoor units. as well as connection to new or existing building management systems.for further details of wiring.network utilises two wire. If a power failure occurs. 6. 3. SC-SL2NA-E. non-polar wires (‘AB’ connection). once power is restored. It will monitor and control the start/stop function of up to16 units. Up to 12 SC-SL1N-E units can be connected to a Superlink. 66 .network via 2-core.network via 2-core. operate & monitor the operation of applicable products. The SC-SL1N-E is connected to the Superlink. 4. 3. Note:Please consult dealer for combination of center controls and BMS interface units. 1. It also monitors and controls the following functions for individual units. with the sixteen operation buttons. The unit or group numbers in operation or in need of service are displayed with an LED. groups of units or the complete network: operation mode. It will monitor and control the start/stop function of up to 16 units. return air temperature. 5. you can start-stop. monitoring and mode setting of up to 64 units. SL1N-E Printed board SW1 ten's place SW2 one's place SW3 Address setting switch Set address number will be the address for SC-SL1N-E. set point temperature. 2. Collective start/stop is also available through the simultaneous on/off button. 2. Simple centralised control. Collective start/stop is also available through the simultaneous on/off button. or 16 groups of units. The SC-SL2NA-E is connected to the Superlink. 8. Air flow and center lock function. • Outer dimensions: H120 x W215 x D25+35*mm. the SC-SL1N-E will resume the operation of the system according to a stored operation condition. with the sixteen operation button. SC-SL4-AE/BE Start-Stop command output An SC-SL2NA-E performs the start/stop control. 35* is the measurement including the part contained in a recess.R410A <Central Control> SC-SL1N-E Start/stop control of up to 16 indoor units either individually or collectively. non-polar wires (‘AB’ connection). 7. SC-SL2NA-E Central control of up to 64 indoor units including weekly timer function as standard. by group or individually. Example of control by a centre control SC-SL2NA-E NEW SC-GIFN-E Interface kit • Applicable products Ventilation fan. If a power failure occurs. louvre position. SC-SL2NA-E and SC-SL4-AE/BE. 4. It is a high quality air conditioner control system that allows up to 64 indoor units to be freely grouped into 1 to 16 groups. Air purifier • By using SC-GIFN-E together with central control such as SC-SL1N-E. SC-SL4-AE/BE hundred's place Terminal block 51X 52 52R 1 2 3 4 5 6 7 8 A B Net work communication line AC220-240V Anomalous signal input Operation signal input Net work To A & B terminal block on SC-SL1N-E.network (consisting of up to 128 indoor units). the SC-SL2NA-E will resume the operation of the system according to a stored operation condition. 5. once power is restored. SC-SL2NA-E. It allows not only the start/stop control but also the monitoring. 6. display of operation statuses such as in operation or in need of service and mode setting such as switching of operation modes of connected units collectively. The SC-SL2NA-E can be connected to an external timer to facilitate timed on/off cycles. 1. The number of units connected to one network are detailed on the table below. error code. The unit or group numbers in operation or in need of service are displayed with an LCD. monitoring. The air conditioning charges calculations of this unit are based on OIML. 24 V During full stop. Ambient temperature during use Model Power supply Power consumption External dimensions (Height x Width x Depth) Net weight Number of connectable units (indoor units) LCD touch panel Inputs SL (Superlink) signal inputs Watt-hour meter pulse input* Emergency stop signal input* Method of data export Calculation software Air-conditioner power proportional distribution pulse input (Maximum) Connecting indoor units number (Maximum) USB / LAN Standard 8 128 Outputs Demand signal input* SC-SL4-BE Operation output Error output SC-SL4-AE/SC-SL4-BE 0 ~ 40oC 1 Phase 100-240V 50/60Hz 18W 172mm x 250mm x 23 (+70) mm 2. Open. 67 . each SUPERLINK. 24 V Normal. If even one unit is abnormal. 9 inches wide 1 systems (Super link. Offers control. the international standard.SC-SL4-AE/BE Indoor unit 128 units MHI introduces the full colour touch screen central control SC-SL4-AE/BE. Control with PC is available by use of internet explorer.system and each power pulse system-” and uses USB memory. closed.0kg up to 128 units Colour LCD. Indoor units can be controlled. monitored and interrogated either individually. Open * The receiving side power supply is DC 12V (10mA). If even one unit is operating. each group. Closed 1 point maximum rated current 40mA.) 8-point pulse width 100ms or more 1 point non-voltage a contact input continuous input (closed. scheduling and service/maintenance functions for up to 128 indoor units. 2 or back-up) HUB Collective stop signal input Watt-hour meter pulse input Demand control Electric power calculation function: (for SC-SL4-BE only) Item SC-SL4-BE gives outputs as “electric power consumption kWh data -each indoor unit. forced stop) 2 point non-voltage a contact input continuous input (closed. scheduled. as groups or as blocks of groups with the following functions: Collective option output Control Monitoring Scheduling Administration/Service Run/Stop Operating state Yearly schedule Block definition Ethernet 10 BASE-T/ 100BASE-TX Internet Explorer Mode (cool/heat/fan/dry/Auto) Mode Today's schedule Group definition Set temperature Set temperature Special day schedule Unit definition Operation permitted/prohibited Room temperature Time and date setting Fan speeds Operation permitted/ prohibited Alarm history Air direction Fan speed Energy consumption calculation period Filter sign reset Air direction Energy consumption cumulative operation time Demand control (3 steps) Filter sign Emergency stop Maintenance (1. with 9 inch interactive LCD display. demand control) 1 point maximum rated current 40mA. etc). SUPERLINK. Control and monitoring functions of the a/c system for up to 96 indoor units can be integrated to a central control point via the building management system network.No.No. Please consult your dealer when using this central control. An IP address filter function combined with three-level user authentication check also ensures security.communication data to LonWorks code.web gateway. 1 system 48 units LonWorks network (FTT-10) SUPERLINK. is required. SUPERLINK. 2 system 68 Network for lighting Emergency sensor network SC-ADNA-E 48 units Additional engineering service cost etc. 64 units 48 cells HUB 48 cells Ethernet 10 BASE-T/ 100BASE-TX SUPERLINK. is required.0. Please consult your dealer when using this gateway. 2 system 64 units Emergency sensor network Additional engineering service cost etc. Monitor resolution 1024 x 768. operation is via Internet Explorer. Simple installation is assured with no special software requirements. communication test by qualified person regarding electric cost calculation function is required before commissioning. SUPERLINK. Control and monitoring functions of the a/c system for up to 96 cells (some cells can have two or more indoor units and total number of indoor units can be up to 128 units) can be integrated to a central control point via the building management system network. In case of SC-BGWNA-B. SC-BGWNA-B (BACnet gateway) Production by order (SC-BGWNA-B is with electric power calculation function) SC-BGWNA-A/B is an interface device that converts MHI’s Superlink. is required.0 or 7. . Web browser requirements: Internet Explorer 6. 48 cells 48 cells Network for lighting SC-ADNA-E 64 units SUPERLINK.No.R410A <PC windows central control> SC-WGWNB-A/SC-WGWNB-B (Web gateway) (SC-WGWNB-B is with electric power calculation function) Production by order Control and monitoring of up to 96 cells (some cells can have two or more indoor units and total number of indoor units can be up to 128 units) centralised to a network PC using the Superlink.No. Please consult your dealer when using this gateway.No. A low power embedded CPU and compact flash ROM ensure a large storage capacity with high reliability (no moving parts such as a PC fan.No. 1 system Ethernet 10 BASE-T/100BASE-TX BACnet I/P Protocol.communication data to BACnet code. 1 system Internet Explorer Additional engineering service cost etc. Cell pulse Watt meter pulse input P1 P2 P3 P4 (in case of SC-BGWNA-B) SC-LGWNA-A (LonWorks gateway) Production by order SC-LGWNA-A is an interface device that converts MHI’s Superlink. Cell <BMS interface unit> SC-BGWNA-A. 2 system 64 units SC-ADNA-E pulse Watt meter pulse input P1 P2 P3 P4 (in case of SC-WGWNB-B) PC requirements: Windows XP or Windows Vista or Windows 7. Operation data is stored for the 30 minute period preceding a fault occurring and details are displayed on the 7-segment reading. This function can be used to help detect any installation errors. no need for a separate drain tray to be installed. This design also means that the base plate of the air flow compartment acts as a drain tray connected to a drain pipe that runs through the mechanical compartment. All outdoor unit PCBs are also equipped with a 7-segment digital display for detailed operation history and fault finding. Air flow chamber Mechanical chamber Service maintenance and trouble shooting tasks can be carried out easily via the wired remote controller. EEV and valve operation. The outdoor unit control box is also equipped with a switch to invoke a 'test-run' mode. indoor/outdoor unit matching errors. so a simple connection of a drain hose to the base of the unit is all that is required. allowing easy access to serviceable parts by simply removing the panel. A 'pump-down' switch on the PCB allows refrigerant to be recovered with the compressor protected. Outdoor unit PCB 7-segment display Automatically produced test-run report Operation data storage during servicing 6 Operation data storage when a fault occurs Method of connecting Mente PC in the combination Multi system Indoor unit Indoor unit Indoor unit Indoor unit Indoor unit Indoor unit 69 .Service/maintenance and monitoring The design of the outdoor units separates the air flow compartment from the mechanical compartment. as well as a cooling test operation to assist commissioning. including specifying work. product liability issues and the required after sales service (including spare parts supply) will be provided by Intesis as it is an Intesis product. product quality (repair and replacement issues).R410A INTESIS BMS Interface for MHI air conditioners All technical support. For details concerning such matters please directly contact Intesis. compatibility issues. Product sales and delivery will be conducted by Intesis as well. Integration of MHI KX in your KNX installation by Superlink MH-AC-KNX-48 TOUCH SCREEN (Max 48 indoor units / Superlink I & II) MH-AC-KNX-128 (Max 128 indoor units / Superlink II) Alams Windows Lighting Energy blinds management HVAC INTEGRATED GATEWAY • Bidirectional: Supervision and Control • Robust and reliable hardware • Direct connection to KNX TP-1 BUS • Independent management of communications • Power supply: 230 VAC 50/60Hz • Wall mounting case Integration of MHI KX in your Modbus installation by Superlink MH-AC-MBS-48 (Max 48 indoor units / Superlink I & II) MH-AC-MBS-128 (Max 128 indoor units / Superlink II) INTEGRATED GATEWAY • Bidirectional: Supervision and Control • Robust and reliable hardware • Modbus TCP or Modbus RTU RS-485/RS-232 • Independent management of communications • Power supply: 230 VAC 50/60Hz • Wall mounting case 70 MODBUS . intesis.com +34 938047 134 71 . URL email tel http://www.com [email protected] of MHI PAC in your KNX installation by Remote control line MH-RC-KNX-1i Example : Device as Master Example : Device as Slave TOUCH SCREEN Windows blinds • Protocol : KNX TP-1 bus • Dimension : 71 x 71 x 27 mm • External Power supply : no need Alams TOUCH SCREEN Energy management Windows blinds Lighting Alams Energy management RC-E5 Lighting HVAC HVAC Integration of MHI PAC in your Modbus installation by Remote control line MH-RC-MBS-1 Example : Device as Master MODBUS Example : Device as Slave MODBUS • Protocol : Modbus RTU (RS-485) • Dimension : 93 x 53 x 58 mm • External Power supply : no need RC-E5 Integration of MHI PAC in your EnOcean installation by Remote control line MH-RC-ENO-1i/1iC Example : Device as Master Example : Device as Slave RC-E5 • Protocol : EnOcean 1i : 868MHz@EU 1iC : 315MHz@USA. ASIA • Dimension : 100 x 70 x 28 mm • External Power supply : no need Please access the followings for details. Durability of KX6 series for anticorrosion is about two times that of standard outdoor units under the same conditions.0kW (220V) Production by order Sea breeze Sea Model No.0kW (220V) 50. welded parts. Preventing corrosion by salt damage or sulfurous acid gas has made service life of KX6 series longer while its exterior appearance has been greatly improved.R410A Outdoor units Corrosion Protection Treatment series 4~48hp (11.0kW (220V) 45. FDCS112KXEN6 FDCS140KXEN6 FDCS155KXEN6 FDCS224KXE6M FDCS280KXE6M FDCS335KXE6M FDCS335KXE6M-K FDCS400KXE6M FDCS450KXE6M FDCS504KXE6M FDCS560KXE6M FDCS560KXE6M-K FDCS615KXE6M FDCS680KXE6M Nominal Cooling Capacity 11.0kW (220V) 15.5kW (220V) 40.5kW (220V) 33.5kW (380V) 33. For outside sheet metals.4kW (380V) 28.2kW (380V) 14.0kW (380V) 33.5kW (380V) 68. fan guard.0kW) are the same as that of the standard KX6 series showed on previous pages.5kW (220V) 22.4kW (380V) 56.2kW (220V) 14.0kW (380V) 15.0kW (380V) 45.0kW (380V) 50. • Specifications and Dimensions are the same as that of the standard KX6 series showed on previous pages.5kW (380V) 22.0kW (380V) 56.0kW (220V) 56.0kW (380V) • Combination systems:26~48hp (73.5kW~136. 72 .5kW (380V) 40.0kW) All KX6 outdoor series are available with special coating applied for not only sheet metals but also small parts in order to prevent salt corrosion caused by sea breeze in area along coast line (Within approximately 500m from coast line). FDCS112KXES6 FDCS140KXES6 FDCS155KXES6 FDCS224KXE6G FDCS280KXE6G FDCS335KXE6G FDCS335KXE6-K FDCS400KXE6 FDCS450KXE6 FDCS504KXE6 FDCS560KXE6 FDCS560KXE6-K FDCS615KXE6 FDCS680KXE6 Nominal Cooling Capacity 11.5kW (220V) 68.0kW (380V) 61.0kW (220V) 33. fin guard and other major parts.2kW~136.4kW (220V) 28.0kW (220V) 61.4kW (220V) 56. • Non-CE Marking models. Cation electrodeposition coating is used for undercoat plus polyester powder coating or acrylic backed coating for top coat and corrosion protection is applied for heat exchanger. Model No. 20*. The following points should be kept in mind during installation and maintenance of the outdoor units. it cannot be perfectly free from rusting. (3) If any scratch or damages occurred on the outdoor unit during installation. (2) Apply rust preventive at regular intervals for maintenance depending on the conditions at the installation place (consulting with the withstanding capacity). repair it carefully. (3) Confirm reset of screw tap after maintenance. FDCS560KXE6-K / KXE6M-K (For combination) 12.Additional treatment from the standard KX6 series showed on previous pages *FDCS335KXE6-K / KXE6M-K. Maintenance (1) Clean salt grains on the outdoor unit with fresh water periodically. (2) Select a well-drained place to install. if missing it may cause corrosion occurred from the hole of screw tap. (4) During prolonged non operation periods. provide a windbreak to protect it from direct sea breeze and salt water splash. protect the unit with covering.14~24HP 4~12HP Exterior panel undercoat: Cation electrodeposition coating topcoat: polyester powder coating or acrylic baked coating undercoat: Cation electrodeposition coating topcoat: acrylic baked coating Base plate undercoat: Cation electrodeposition coating topcoat: polyester powder coating or acrylic baked coating undercoat: Cation electrodeposition coating topcoat: acrylic baked coating undercoat: Cation electrodeposition coating topcoat: acrylic baked coating Drain pan application of anticorrosion compound Fan motor 4~6HP Fan motor base 8~12HP application of anticorrosion compound application of anticorrosion compound application of anticorrosion compound Fin Precoated Aluminum Blue Fins in high anticorrosion specification Precoated Aluminum Blue Fins in high anticorrosion specification pipe application of anticorrosion compound application of anticorrosion compound Side plate application of anticorrosion compound application of anticorrosion compound Compressor application of anticorrosion compound application of anticorrosion compound Accumulator application of anticorrosion compound application of anticorrosion compound Receiver application of anticorrosion compound application of anticorrosion compound 4~6HP galvanized steel sheet + undercoat: Cation electrodeposition coating + topcoat: acrylic baked finish Heat exchanger Control box Baffle plate Service valve bracket 8~12HP application of anticorrosion compound 4~6HP 8~12HP application of anticorrosion compound 4~6HP 8~12HP application of anticorrosion compound galvanized steel sheet + undercoat: Cation electrodeposition coating + topcoat: acrylic baking finish Screw tap for exterior panel zinc coating + chromate treatment + fluorine coating zinc coating + chromate treatment + fluorine coating Screw tap for inside of exterior panel zinc coating + chromate treatment + fluorine coating zinc coating + chromate treatment + fluorine coating Corrosion protection treatment complies with regulation of The Japan Refrigeration and Air Conditioning Industry Association Caution Even if the outdoor unit is protected with the anti-salt damage treatment. Installation (1) When installing the outdoor unit close to the coastal area. 73 . 5 kW 40. 74 . FDCH335CKXE6G-K FDCH400CKXE6G FDCH450CKXE6G FDCH504CKXE6G FDCH560CKXE6G FDCH560CKXE6G-K FDCH615CKXE6G FDCH680CKXE6G Nominal Cooling Capacity 33.5 kW 80.0 kW 56.5 kW 113.4 kW 56. the High Head models can not be applied.0~136. In case Indoor unit is higher than outdoor unit.0 kW 101. the High Head models can not be applied.5 kW 68. FDCH735CKXE6G (FDCH335-K+FDCH400) FDCH800CKXE6G (FDCH400x2) FDCH850CKXE6G (FDCH400+FDCH450) FDCH900CKXE6G (FDCH450x2) FDCH960CKXE6G (FDCH450+FDCH504) FDCH1010CKXE6G (FDCH504x2) FDCH1065CKXE6G (FDCH504+FDCH560) FDCH1130CKXE6G (FDCH560x2) FDCH1180CKXE6G (FDCH560-K+FDCH615) FDCH1235CKXE6G (FDCH615x2) FDCH1300CKXE6G (FDCH615+FDCH680) FDCH1360CKXE6G (FDCH680x2) FDCH335CKXE6G-K & FDCH560CKXE6G-K are only used for combining with other models.5 kW 130.0 kW 85.0kW) Model No.0 kW 90.0 kW 96.0 kW 50.0 kW 106.0 kW 45.R410A Outdoor units High Head series (100m) cooling only 14~48hp (40.0 kW 61. (When the outdoor unit is located at higher position than the indoor unit) Nominal Cooling Capacity 73.0 kW Production by order Model No.0 kW 136.0 kW 123. *2 In case of less than 50m.4m Range of operation 50 +43ºC Height difference 50~100m 40 *2 30 Indoor unit Indoor unit Max height difference between indoor units: 18m 20 Cooling 10 0 -5ºC -10 Furthest indoor unit : 160m * The difference between the longest and shortest indoor unit piping from the first branch 1 must be within 40m.0 kW • Non-CE Marking models. • Maximum allowable height difference between the outdoor and the indoor unit located at the lowest height position has been increased from 50m to 100m.0 kW 118. FDCH335CKXE6G-K FDCH400CKXE6G FDCH450CKXE6G Total length: 1000m To the first branch: max 130m From the first branch to the furthest indoor unit: 90m *1 FDCH504~680CKXE6G Max: 10m Outdoor unit Max: 5m Indoor unit Max height difference: 0. and outdoor temp.5 16 29.58(1 1/8")] ø28.0 16.0 85.7(1/2") Liquid line ø15.2 ø22.0 25.0 33.Specifications Model FDCH400CKXE6G FDCH450CKXE6G FDCH504CKXE6G FDCH560CKXE6G FDCH615CKXE6G FDCH680CKXE6G 20HP 22HP 24HP 18HP 14HP 16HP 3 Phase 380V.46 31.58(1 1/8") ø25.92(1 3/8")] 50~160 69 59 560CKXE6G-K 615CKXE6G 42HP Combination (FDCH) Exterior dimensions Net weight Refrigerant charge FDCH960CKXE6G 450CKXE6G 504CKXE6G 34HP Item Electrical characteristics 20.58(1 1/8") 50~200 % Capacity connection 50~160 Number of connectable indoor units 40 44 49 36 40 36 Item Nominal horse power Power source Nominal capacity Item Model Nominal horse power Power source Nominal capacity Electrical characteristics Exterior dimensions Net weight Refrigerant charge Refrigerant piping size Cooling Starting current Power consumption Cooling Running current Cooling HxWxD R410A Liquid line Gas line Capacity connection Number of connectable indoor units Item kW A kW A mm kg kg Electrical characteristics Exterior dimensions Net weight Refrigerant charge Refrigerant piping size 53 Cooling Starting current Power consumption Cooling Running current Cooling HxWxD R410A Liquid line Gas line kW A kW A mm kg kg mm(in) % Model Refrigerant piping size 96. During operation these values are somewhat higher due to ambient conditions.5x2 ø19. Sound pressure level indicates the value in an anechoic chamber.05(3/4") ø31.0 45.37 24.22(7/8") ø38.0 106. 2.5 59.0 47.0 37. 60Hz kW Cooling 56.22(7/8") ø38.5m. and outdoor temp.8(1 1/4")[ø34.70 41.0 49.24 33.94 38.8(1 1/4") [ø34.52 44.5x2 ø19.0 61.0 61.0 16 40. 3.0 A Starting current 8 kW Electrical characteristics Power consumption Cooling 16.3 326+358 Cooling Starting current Power consumption Cooling Running current Cooling HxWxD R410A Liquid line Gas line Capacity connection Number of connectable indoor units kW A kW A mm kg kg FDCH800CKXE6G FDCH1180CKXE6G 118.6 65 FDCH1065CKXE6G FDCH1130CKXE6G 504CKXE6G 504CKXE6G 504CKXE6G 560CKXE6G 36HP 38HP 3 Phase 380V.21 30. Cooling: Indoor temp.88(5/8") mm(in) Refrigerant piping size Gas line ø28. Heating: Indoor temp.16 55.0 27.5x2 ø22.05(3/4") ø31.4(1") [ø28.74 45.2 2048x2700x720 377x2 11. 60Hz 101.79 20. of 7ºCDB. 6ºCWB.1 2048x2700x720 358x2 11. 75 . Piping length is 7. 60Hz 80. of 27ºCDB.3 36. [ ] : Pipe sizes applicable to European installations are shown in parentheses.96 73. of 20ºCDB.5 68.54 24.8 80 1.5 mm(in) Combination (FDCH) Nominal horse power Power source Nominal capacity FDCH735CKXE6G 335CKXE6G-K 400CKXE6G 26HP Combination (FDCH) FDCH1235CKXE6G 560CKXE6G 560CKXE6G 40HP 113.4 mm(in) % 69 FDCH850CKXE6G FDCH900CKXE6G 400CKXE6G 400CKXE6G 400CKXE6G 450CKXE6G 28HP 30HP 3 Phase 380V.5 130.35 60. of 35ºCDB.5 62.2 1690x2700x720 326x2 11.27 12. 60Hz 123.4 40.98 14.73 11.1(1 1/2") 50~130 72 76 680CKXE6G 680CKXE6G 48HP 136.2 % Model Capacity connection Number of connectable indoor units Nominal horse power Power source Nominal capacity 73.9 22.8 36.5 ø12.3 HxWxD Exterior dimensions mm 1690x1350x720 2048x1350x720 Net weight kg 377 326 358 R410A Refrigerant charge kg 11.0 50. The data are measured under the following conditions(ISO-T1).9 19.1 30.97 Running current Cooling A 25.0 16 22. 19ºCWB.6 67.5 65.0 64.1(1 1/2") 50~130 62 66 FDCH1300CKXE6G FDCH1360CKXE6G 615CKXE6G 615CKXE6G 615CKXE6G 680CKXE6G 44HP 46HP 3 Phase 380V.92(1 3/8")] 50~160 58 61 FDCH1010CKXE6G 450CKXE6G 450CKXE6G 32HP 90.58 50.5 Cooling dB(A) Sound pressure level 63. FDCH335CKXE6G-K. (3) The unit name plate is attached on the lower right corner of the front panel. Please cut off a half-blank with nippers in using these ports. (6) Anchor holes marked “L J” (four holes for M10) are for a renewal installation. long hole 40 x 80 (under side) M10 x 4 places ø45 x 3 places ø20 x 10 places ø9.58(Brazing) ø12.52(Flare) 230 x 60 Dimensions 1 2 L1 L2 L3 L4 500 Open H1 H2 H3 H4 1500 – No limited No limited 1000 No limited No limited – When more than one unit is installed Wall height H3 L3 L2 L5 L6 L1 (Unit front side) Wall height H2 10 100 10 Open L4 Dimensions A B L1 500 Open L2 10 200 L3 100 300 L4 10 Open L5 0 400 L6 0 400 H1 1500 No restrictions H2 H3 H4 76 10 100 Installation example Wall height H4 Notes: (1) The unit must be fixed with anchor bolts.7(Flare) ø88(or ø100) ø50 (right . 450CKXE6G Content Refrigerant gas piping connection pipe Refrigerant liquid piping connection pipe Refrigerant piping exit hole Power supply entry hole Anchor bolt hole Drain waste water hose hole Drain hole Refrigerant oil equalization piping connection pipe Carrying in or hole for hanging 400 450 ø25. (7) The oil-equalising pipe K should be used when outdoor units are used in combination.R410A Dimensions All measurements in mm. (2) Leave a 2m or larger space above the unit. (For 14. 400CKXE6G. (4) The ports for refrigerant pipe and power cable penetrations are covered with half-blanks. (5) Use a ø88 port for refrigerant pipe connection. left . front).4(Brazing) Installation example ø28.16Hp only) 335-K Wall height H2 Mark A B C D F G H K L No restrictions No restrictions 1000 No restrictions No restrictions No restrictions . left . 680CKXE6G Mark A B C D F G H K L Content Refrigerant gas piping connection pipe Refrigerant liquid piping connection pipe Refrigerant piping exit hole Power supply entry hole Anchor bolt hole Drain waste water hose hole Drain hole Refrigerant oil equalization piping connection pipe Carrying in or hole for hanging Installation example ø28.58(Brazing) ø12. (7) The oil-equalising pipe K should be used when outdoor units are used in combination. (3) The unit name plate is attached on the lower right corner of the front panel. FDCH504CKXE6G. (4) The ports for refrigerant pipe and power cable penetrations are covered with half-blanks. (5) Use a ø88 port for refrigerant pipe connection.7(Flare) ø88(or ø100) ø50 (right . 560CKXE6G. front). 615CKXE6G. 560CKXE6G-K. (6) Anchor holes marked “L J” (four holes for M10) are for a renewal installation. 77 . (2) Leave a 2m or larger space above the unit. long hole 40 x 80 (under side) M10 x 4 places ø45 x 3 places ø20 x 10 places ø9.Dimensions All measurements in mm.52(Flare) 230 x 60 Dimensions 1 2 L1 L2 L3 L4 H1 H2 H3 H4 500 Open 10 10 100 100 10 Open 1500 – No limited No limited 1000 No limited No limited – Notes: (1) The unit must be fixed with anchor bolts. Please cut off a half-blank with nippers in using these ports. Creed • We strongly believe that the customer comes first and that we are obliged to be an innovative partner to society. and in the defence sector “MHI. from land and sea to air and space. harmony. president of Mitsubishi Goshi Kaisha in the 1920’s. the mental attitude of the employees. living up to the trust of customers with outstanding technology. • We shall strive for innovative management and technological development from an international perspective. and helping people worldwide lead safe and fulfilling lives.” Corporate Governance and Compliance Contribution to Society through Company Business Transportation & Security Power & Energy MISSION MISSION Supply all areas of the world with highly efficient.” “the environment. The reason for instituting the present creed is so that all of us can call to mind our one hundred years of tradition. and strive for further development in the future. MHI continues its efforts to fulfil its three corporate social responsibilities (CSRs): “corporate governance and compliance. has a creed of this type. clean energy VISION A company with expertise in all modes of transportation. Ltd. human rights and labour. • We base our activities on honesty. to indicate the essential attitude of the company. In the spirit of this creed.” Environment & Society MISSION Help people lead fulfilled lives 78 MHI is a global enterprise with a vision for sustainable growth. Contribution to Society through Company Business Environment.” and “contribution to society through business activities. and the future directions of the company. Human Rights and Labour Issued 1 June 1970 MHI’s creed was established based on “The Three Corporate Principles” shared by the Mitsubishi Group from the company’s beginnings.R410A Mitsubishi Heavy Industries /further information Mitsubishi Heavy Industries operates a continuous CSR (Corporate Social Responsibility) policy. It was instituted in 1970 on the basis of the policy advocated by Koyata Iwasaki. Reason for Instituting the Creed In Japan there are many enterprises with their own “creeds” which simply represent their management concept. Industries MISSION Support manufacturing activities worldwide . a premier global organization. with a role to realise a sustainable society through it’s various areas of business. also. Mitsubishi Heavy Industries. and a clear distinction between public and private life. in all aspects of its business activities. saving resources. 7. use. Endeavour to reduce the burden on the environment by preventing pollution. thus contributing to the establishment of a society in which sustainable development is possible. Pursuant to the express provision of Section 1 of its creed that “We strongly believe that customers come first and that we are obligated to be an innovative partner to society. manufacturing. Define roles and responsibilities regarding environmental protection by developing and maintaining a corporate organisation designated for environmental protection. implementing and evaluating voluntary standards where necessary. MHI shall endeavour. Provide environmental training and other programs to enhance the environmental awareness of all company employees. strive. To this end. Endeavour to develop and provide advanced. In order to realise its basic policy. such as providing environment-related information to the public and social contribution activities. designing. highly reliable. 5. and create and implement corporate policies and procedures on environmental matters. 1. a basic policy on environmental matters has been established. and to become actively involved in technological co-operation overseas in areas of environmental protection. to reduce the burden on the environment and shall concentrate and fully utilise its technological capabilities for the development of technologies and products that will protect the environment. 2012 Europe Major subsidiaries 16 North. MHI has set the following seven conduct guidelines. beyond mere compliance by enacting. Number of offices/plants by region (Consolidated) as of April. 3. unique technologies and products that contribute to solving environmental and energy problems.The KX6 product range has been developed in compliance with the Mitsubishi Heavy Industries Policy on the Environment. 4. as a matter of primary importance. and to endeavour to continuously improve and promote environmental protection activities by establishing environmental goals and targets. and recycling in all aspects of the companyís business activities in R&D. Recognise that environmental protection is top priority in the companyís operations. manufacturing and other business activities. Central & South America Major subsidiaries Japan Head office & domestic offices Research & development centres Asia Major subsidiaries 58 Works Major domestic subsidiaries 25 9 6 14 127 Africa Major subsidiary 2 Oceania Major subsidiaries 2 79 . and encourage the entire company in its endeavours to protect and improve the environment. 2.” MHI shall. while remaining aware that a business enterprise is a member of society. to play a useful role in the development of society. service and disposal. procurement of materials. and take steps to expand public relations activities. through its R&D. In order to make the sustainable development of society possible. 6. transportation. reducing waste. Endeavour to protect the environments of foreign countries by carefully examining the consequences of the companyís overseas business operations and the exportation of its products. Comply with national and local environmental laws and regulations. reusing materials. saving energy. From new energy development and environmental concerns to the exploration of space. air-conditioners. power systems. quality products through untiring technological research and development. pollution reduction and environmental control systems. are as harmonious as an orchestra. with the advent of the 21st century MHI is confronting a variety of issues to ensure the realisation of a society in which there is harmony between mankind and technology.global activity On the land and sea. Ships. aerospace systems – the MHI product lines which create rich and comfortable living environments. MHIís stage of operations is expanding limitlessly. We are highly esteemed in the world for providing high • Ultra-High Steel Stacks • Refuse Incineration Plants • Night Soil Treatment Plants • Electrostatic Precipitators • Flue Gas Desulfurization System • Fluidized Incinerators • CFC Collecting Equipment • Crude Oil Storage Barges • LNG Tanks • Boilers & Turbines • Oil Production Plants • Contra-Rotating Propellers • Thermal Power Plants • Combined Cycle Plants • Fuel Cells • Water Turbines • Wind Turbines • Geothermal Power Plants • PWR Nuclear Power Plants • Uranium Enrichment Equipment • FBRs • Co-Generation Systems • Spillway Radial Gates • Steel Bridges • Penstocks • Desalination Plants • Physical Distribution Equipment • Engines T RGY S/ENE URCE RESO T N EN TIO N ME ON TA VIR OR EN SP PM LO VE AN DE TR AL 80 • Toll Collection Machine Systems • Forklift Trucks • Helicopters • Aircraft • Railway Maintenance Equipment • LNG Carrier • Container Ships C LO • Unloader & Container Cranes • Mechanical Parking Facilities • Integrated Automated Storage Systems • Rubber & Tyre Machinery • Skyrails • Monorail Cars • New Transportation Systems • Passenger Boarding Bridges . steel structures. We manufacture more than 700 different products which support various industrial and civil activities in both domestic and international markets. in the sky and even in space. machinery for both industrial and general use. What creates this harmony is MHIís general technological expertise developed over more than a century of hard work. • Chemical Plants • Wind Tunnel/Experiment Equipment • Casting Machines • Strip Mill • Cement Plant • Stepless Variable Speed Gears • Industrial Robots • Injection Moulding Machines • Pulp & Paper Machinery • Corrugation Machines • Box Making Machines • Machine Tools • Ceiling Recess Packaged Air Conditioners • Automotive Air Conditioners • Residential Use Split Air Conditioners • Refrigeration Units • Dry Cleaning Machines • Food Machinery • Cruise Ships • Multi-purpose Dome • Stage Machinery Systems • Cable Layer • Printing Machinery INDUS TRIAL LEI SU RE /LIF IN EST FO YLE RM AT IO N SY ST EM • Oceanographic Research Ships • Deep Submergence Research Vehicles • Communications Satellite Rockets • Space Transportation • Rockets & Engines O EL V DE NT E PM CE D N EFE • Submarines • Naval Vessels • Jet Fighters • Helicopters • Missiles • Tanks & Infantry Fighting Vehicles 81 . or places containing carbon fibers could lead to fires. Before use . or at coastal areas where the unit is subject to salt breezes. three to ten minutes. After defrosting. Air-conditioning & Refrigeration Systems Headquarters HB91-13KX03E MITSUBISHI HEAVY INDUSTRIESMAHAJAK AIR CONDITIONERS CO.. Ltd. Always commission the installation to a dealer or specialist. places where the exhaust of the heat exchanger is sucked in. In the actual installation state. The "Automatic defrosting device" will function to remove this frost. However. August 2013 (3B)R Mitsubishi Heavy Industries-Haier (Quingdao) Air-conditioners Co. Take measures by installing ventilation devices. frost will stick to the heat exchanger of the outdoor unit. Ltd. The refrigerant (R410A) used for Air conditioner is non-toxic and inflammable in its original state.LTD. Use in places with high ceilings If the ceiling is high. Minato-ku. Do not use this for cooling vehicles or ships. Tokyo. After heating for approx. we recommend the maintenance contract (charged for) by a specialist. Improper installation will lead to water leakage. ·Snow prevention Install a snow-prevention hood so that the snow does not obstruct the air intake port or enter and freeze in the outdoor unit. In this case.jp Our factories are ISO9001 and ISO14001 certified. in consideration of a state where the refrigerant leaks into the room.Before starting use Heating performance Refrigerant leakage The heating performance values (kW) described in catalog are the values obtained by operating at an outdoor temperature of 7 C and indoor temperature of 20 C as set forth in the ISO Standards. Because of our policy of continuous improvement. Mitsubishi Heavy Industries-Haier (Quingdao) Air-conditioners Co. etc. if the outdoor temperature is too low and the heating performance is insufficient. Servicing the air-conditioner After the air-conditioner is used for several seasons..co.mhi. If the oil adheres to the heat exchanger. and the synthetic resin parts may deform and break. electric shocks and fires. the heat exchanging performance will drop. etc. Ltd. Certified ISO 9001 Certified ISO 14001 ISO 14001 Certificate 04104 1998 0813 E5 BIWAJIMA PLANT Mitsubishi Heavy Industries. Mitsubishi Heavy Industries. the value is normally larger than the values given in the catalog due to the effect of surrounding noise and echo. etc.. If use is continued. Use in acidic or alkaline atmosphere If this unit is used in acidic atmosphere such as hot spring areas having high level of sulfuric gases or in alkaline atmosphere including ammonia or calcium chloride. the piled snow could block the air intake port. measures against refrigerant leaks must be taken in small rooms where the tolerable level could be exceeded. Installation in a place where combustible gas could be generated. Make sure that the outdoor unit is stable in installation. Safety Precautions Air-conditioner usage target Installation The air-conditioner described in this catalog is a dedicated cooling/heating device for human use. BIWAJIMA PLANT Mitsubishi Heavy Industries. such as in a kitchen or machine factory. As the heating performance decreases as the outdoor temperature drops. etc.Ltd. animals or plants.. Do not use it for special applications such as the storage of foodstuffs. hot air will be blown again. Use in oil atmosphere ·Snow piling Avoid installing this unit in as atmosphere where oil scatters or builds up. will corrode. Automatic defrosting device If the temperature is low. mist may be generated. Water leakage or current leaks could occur. and the frost will be removed. a frame that is 50cm or higher than the estimated snow fall must be installed underneath the outdoor unit. Air-Conditioning & Refrigeration Systems 16-5. and the humidity is high. In areas with heavy snow fall. dirt will build up in the air-conditioner causing the performance to drop. the heating performance will drop. we reserve right to make changes in all specifications without notice. Always read the "User s Manual" thoroughly before starting use. Indication of sound values Use in snowy areas The sound values are the values (A scale) measured in a chamber such as an anechoic chamber following the ISO Standards. the outer plate or heat exchanger. Please ask a dealer or specialist when you use an air conditioner in places differing from a general atmosphere. Fix the unit to stable base. In addition to regular servicing. Usage place Do not install in places where combustible gas could leak or where there are sparks. This could cause the quality of the items to drop.. 108-8215 Japan http://www. Edited in Japan . LTD.Ltd. Air-conditioning & Refrigeration Systems Headquarters MITSUBISHI HEAVY INDUSTRIESMAHAJAK AIR CONDITIONERS CO. Take the following measures when installing the outdoor unit in snowy areas. Konan 2-chome. flow or accumulate. it will stop. precision devices or valuable art. install a circulator to improve the heat and air flow distribution when heating. use other heating appliances as well. Take this into consideration when installing.
Copyright © 2024 DOKUMEN.SITE Inc.