20-30_KVA_Cummins

March 25, 2018 | Author: Karunesh Mathur | Category: Diesel Engine, Engines, Mechanical Engineering, Machines, Rotating Machines


Comments



Description

Diesel Generator SetX2.7 Series Specification Sheet 20-30 kVA, 16-24 kWe Prime Latest Technology And Unmatched Performance Lowest Operating Cost And Comprehensive Warranty ƒƒThe Cummins® X2.7 series rugged engine and world class Stamford alternator powered diesel generator set ƒƒAdvanced in-cylinder technology to meet latest emission norms without any after-treatment device ƒƒBest in class transient reponse with 100% block loading capacity ƒƒSmart aesthetic and superior finish ƒƒCompact in size with optimum power to weight ratio ƒƒHighly reliable and durable product ƒƒAll elements are designed to work together to maximize efficiency even at part loads, offering the advantage of lowest operating costs. ƒƒ500 hours / 1 year service interaval ƒƒIndustry acknowledged best-in-class comprehensive warranty on the entire package including rubber components Environment Friendly Power Single Source Power Assurance ƒƒClass defining technology engine is designed to meet stringent exhaust emission tests as per revised MoEF norms, thus offering environment friendly power. ƒƒThe Cummins® diesel generator sets are available with the lowest noise levels in its range ƒƒAll the major components – the engine, alternator, control system and canopy are designed, manufactured and tested by Cummins India. ƒƒBest and Largest customer support network in India, capable of providing round-the-clock service and spares support ƒƒAll these things put together, Cummins® offers you SINGLE SOURCE POWER ASSURANCE ƒƒIntuitive operator interface which includes LED backlit LCD display with tactile feel soft-switches and generator set status LED lamps ƒƒRemote Start-Stop ƒƒEngine Metering: Oil pressure. Sensor failure.meets the requirement of relevant ISO. EN. Heavy duty air cleaner. ƒƒData Logging: Engine Hours. fault annunciation. radiator cooled engine ƒƒWell designed air handling system with —— Dry type. Battery Over/Under/Weak Volts.7 Series Engine ƒƒCummins X series. Oil drain pump. Loss of AC Sensing. Control Hours and upto 5 recent fault codes ƒƒConfigurable glow plug control ƒƒ12 Volt DC operation ƒƒSleep mode ƒƒModbus interface (RS485 RTU) ƒƒInPower compatible (PC based service tool) ƒƒCertifications . Engine temperature.Diesel Generator Set X2. The control panel consists of the following parts: ƒƒPS0500 controller ƒƒAluminum bus bars with suitable capacity with incoming/ outgoing terminals ƒƒIndicating lamps for ‘Load ON’ and ‘Set Running’ ƒƒInstrument fuses duly wired and ferruled ƒƒCircuit breakers of suitable rating with overload and short circuit protections ƒƒCritical grade silencer suitably optimized to meet stringent sound emission standards laid down by MoEF / CPCB Mounting Arrangement ƒƒEngine and alternator are mounted on a common MS fabricated base frame with AVM pads. Fail to Crank/ Start. Starting battery voltage. In-line 4 stroke. Revolving field. ƒƒAC Alternator Protection: Over/Under Voltage. Low fuel level. Over/Under Frequency. Replaceable paper element air cleaner with restriction indicator —— Air to air aftercooling for 25 and 30 kVA —— Optimised turbocharger for increased altitude capabilities ƒƒBest in class fuel economy with —— Inline fuel pump for 20. and CE standards Silencers Alternator ƒƒStamford PT1 alternator frames from Cummins Geneartor Technology ƒƒBrushless type. Electronic Governing ƒƒControl Panel: Microprocessor / relay based AMF control panel ƒƒOthers: Trolley mounted mobile sets . Mil Std. 3 cylinder. ƒƒEngine Protection: Low lube oil pressure. This control includes an intuitive operator interface that allows for complete generator set control as well as system metering. Current (phase and total). ƒƒBase frame with integral fuel tank is provided with drain plug. inlet and outlet connection. air vent. kVA (phase and total) and Frequency. Cranking lockout. level indicator and provision for cleaning Optional ƒƒEngine: Coolant heater. Engine running hours ƒƒAC Alternator Metering: L-L Voltage and L-N Voltage. configuration and diagnostics. High/Low coolant temperature. 25 kVA with A1 class mechanical governing —— Rotary fuel pump for 30 kVA with A1 class mechanical governing —— Spin on fuel filter ƒƒStandard integral set-mounted radiator system. Self excited alternator conforming to IS/IEC 60034-1 ƒƒ3 Phase reconnectable winding with 12 terminals brought out for connection ƒƒDedicated winding specially designed for 1 phase operation ƒƒBetter motor starting capability ƒƒBest in class efficiency ƒƒCompact design with sealed bearings for longer life and lesser maintenance ƒƒImpregnation on all wound components for better mechanical strength Control Panel Control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. designed and tested for 50°C ambient temperature ƒƒFull flow spin on lube oil filter ƒƒFirst fill of lube oil and coolant ƒƒElectrical starter motor with soft start engagement feature ƒƒBattery charging alternator ƒƒ1X12 V DC battery ® Specification Sheet PS0500 Features Cummins® PowerStart PS0500 control is a microprocessor based generator set monitoring and control system. Screen protected. 7 High Speed Diesel 4.Diesel Generator Set X2.8 (lagging) 28 87 50 Hz.7 Series Specification Sheet Acoustic Enclosure ƒƒSpecially designed to meet stringent MoEF/ CPCB norms of 75 dBA @ 1mtr at 75% load under free field conditions ƒƒThe acoustic enclosure is made of CRCA sheets in munsel green shade and a structural/ sheet metal base frame painted in black. Charge Air Cooled 3.2 8 0.89 and meeting CH4 API categories # With the condition that none of the phases exceeds its rated current . ƒƒHigh quality noise absorbant and fire-retardant grade acoustic Insulation material (Foam) complying to IS 8183 ƒƒTwo point lifting for easy handling at customer site ƒƒDesigned to have optimum serviceability ƒƒAir inlet louvers specially designed to operate at rated load ƒƒMade on special purpose CNC machines for consistency in quality and workmanship ƒƒ11 tank pretreatment process and UV resistant powder coating of all parts to withstand extreme environment ƒƒUse of special hardware for longer life ƒƒFlush styling . Non distorting balanced linear load < 5 % less than or equal to 25% < 2% Stamford (CGT) PI144G PI144H IP23 ±1% H Class 2/3 Double layer lap Dynamically Balanced No load < 1. Non distorting balanced linear load < 5 % less than or equal to 25% < 2% 3.7 High Speed Diesel 4.3-3.7TAA-G2 38 33 Liquid Cooled (EG Compleat 50:50) Turbocharged.3:1 2.35 55 446 Maximum Unbalanced Load across phases# Stamford (CGT) PT144C PT144G IP23 ±1% H Class 2/3 Double layer lap Dynamically Balanced No load < 1. Charge Air Cooled 3.7T-G1 32 27 Liquid Cooled (EG Compleat 50:50) Turbocharged Cummins® X2.35 70 487 Stamford (CGT) PT144E PT144H IP23 ±1% H Class 2/3 Double layer lap Dynamically Balanced No load < 1. 1500 RPM C30D5P Prime 30/24 3 Phase 1 Phase 415 230 0.45 ISO 8528-5 G2 12 V DC Electrical CH4 15W40 7. Non distorting balanced linear load < 5 % less than or equal to 25% Telephonic Harmonic factor < 2% * Fuel consumption data is based on diesel having specific gravity of 0.01 11 2.01 11 2.2 8 0.3:1 2. In-line 95 x 127 18.8 (lagging) 1 42 131 50 Hz.17 5.5 %.no projections ƒƒFluid drains for lube oil and fuel ƒƒFuel filling arrangement inside the enclosure Technical Data Generator set specification Model Duty Power Rating kVA / kWe No.5 318 701 x 600 x 889 6.7 High Speed Diesel 5. of cylinders Bore (mm) x Stroke (mm) Compression ratio Displacement (litre) Fuel Fuel consumption @75% load with radiator and fan* (litre/hr) Fuel consumption @100% load with radiator and fan* (litre/hr) Performance class of generator set Starting system Lube oil specification Lube oil sump capacity.96 6.8 7. 1500 RPM C25D5P Prime 25/20 3 Phase 1 Phase 415 230 0. 1500 RPM Cummins® X2.01 11 2.7TAA-G3 40 39 Liquid Cooled (EG Compleat 50:50) Turbocharged.52 ISO 8528-5 G2 12 V DC Electrical CH4 15W40 7.5 %.35 67 463 Cummins® X2.3-3.3-3. High-Low level (litre) Total lubrication system capacity (litre) Lube oil consumption @ full load** (litre/hr) Total coolant capacity (litre) Exhaust pipe size (inch) Total wet weight (Engine+Radiator)## (kg) Length x Width x Height (Engine) (mm) Mean piston speed (m/s) Combustion air intake @100% load (±5%) (cfm) Exhaust Temperature (°C) Alternator Specification Make Alternator frame Enclosure Voltage regulation (Max. In-line 95 x 127 18. of Phases Output Voltage (V) Power Factor Current (3 phase/ 1 phase) (A) Frequency (Hz) and RPM Engine Specification Make Model MoEF Certified Power (hp) Required Power for Rated kVA (hp) Cooling Aspiration No.) Class of Insulation Winding Pitch Stator Winding Rotor Waveform distortion/ Total Harmonic Distortion C20D5P Prime 20/16 3 Phase 1 Phase 415 230 0.8 (lagging) 35 109 50 Hz.2 8 0.5 %.32 ISO 8528-5 G2 12 V DC Electrical CH4 15W40 7.5 322 701 x 600 x 889 6.85 and conforming to IS:1460. In-line 95 x 127 18. Fuel consumption tolerance is +5% ** Oil consumption data is based on oil having specific gravity of 0.3:1 2.5 322 701 x 600 x 889 6. Cummins Power Generation and Cummins are registered trademarks of Cummins Inc. (040) 2340 9990 Tel.Diesel Generator Set X2.: (044) 2446 8110 / 2446 8113 Fax: (044) 2491 1120 Tel.7 Series Specification Sheet Rating Definitions Conformance Standards Prime Power (PRP): Applicable for supplying power to varying electrical load for unlimited hours.  IS/IEC 60034-1  ISO 3046  IS 1460  ISO 9001  ISO 8528  IS 13018 Typical Enclosed Genset Dimensions Genset Model Rating (kVA) Length (mm) Width (mm) Height (mm) Wet Weight## (kg) Standard Fuel tank Capacity (litre) C20D5P 20 2400 950 1400 1090 87 C25D5P 25 2400 950 1400 1090 87 C30D5P 30 2400 950 1400 1090 87 Approximate weight ## Authorised Representative Cummins Power Generation Offices Bengaluru: Chandigarh: Chennai: Gurgaon: Hyderabad: Jaipur: Kolkata: Lucknow: Mohali: Vadodara: Tel. No.7 20-30 kVA/CPG/VW/August 2014/1000 Cummins India Limited Power Generation Business Unit Cummins India Office Campus Tower-A. PowerCommand. Other company product or service names may be trademarks or service marks of others.: (033) 2287 8065 / 2287 2481 Fax: (033) 2290 3839 Tel.: (0124) 391 0900-01 Fax : (0124) 391 0916 Tel. PGBU/CIL/010/X2. 21.: (0172) 224 0371-73 Fax: (0172) 224 0372 Tel.: (040) 2340 9970 / 2340 9980 Fax.com .: (0522) 230 5049 / 230 5059 Fax: (0522) 230 5035 Tel. Prime Power (PRP) is in accordance with ISO 8528. S. Specifications are subject to change without notice.com www.: (0265) 233 0627 / 3053627 Fax: (0265) 234 0623 Visit our facebook page at : Cummins Power Generation India “Our energy working for you.: (080) 2325 9161 / 63. 6th Floor.: (0141) 236 4944 Fax: (0141) 403 8794 Tel. AmpSentry.cumminsindia. 2325 9165 / 67 Fax: (080) 2325 9164 Tel. All rights reserved.” © 2014 Cummins Power Generation Inc. Balewadi. InPower and are trademarks of Cummins Power Generation.: (0172) 224 0371 / 72 / 73 Fax: (0172) 224 0371 / 72 / 73 Tel. Pune – 411 045 (India) Phone: +91 20 6706 7000 Email: cpgindia@cummins.
Copyright © 2024 DOKUMEN.SITE Inc.