1492-IfM40F Wiring Diagram

March 27, 2018 | Author: pustakam123 | Category: Electrical Connector, Programmable Logic Controller, Electrical Wiring, Relay, Fuse (Electrical)


Comments



Description

TECHNICAL DATABULLETIN 1492 Digital/Analog Programmable Controller Wiring Systems Bulletin 1492 Digital and Analog Wiring Systems Table of Contents Description Page Description Page Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Options and Features Digital (IFM/XIM and Cables). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Analog (AIFM and Cables). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Ordering Digital and Analog Wiring Systems. . . . . . . . . . . . . . . . . . . . . . . . . . 28 Selection Tables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Specifications Digital IFM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 Digital Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 Analog Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180 Marking System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184 Web Site Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186 Quick Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187 Bulletin 1492 Digital/Analog Programmable Controller Wiring Systems 2 Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems 3 Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems Description Connecting to Allen-Bradley PLC I/O is fast, convenient, and reliable with the Allen-Bradley Bul. 1492 wiring system. Unlike conventional terminal blocks, the Bul. 1492 wiring system connects to digital, analog, and high speed counter PLC I/O modules through pre-wired and pre-tested cables. The Bulletin 1492 wiring systems are compatible with modular I/O modules for Bulletin 1756 ControlLogix, 1769 CompactLogix, 1746 SLC 500, and 1771 PLC-5. A select group of wiring system modules are also compatible with the base I/O of the MicroLogix 1200 (40 I/O base only) and 1500 packaged controllers, plus the PowerFlex 700H and 700S drives. In addition, wiring system solutions are available for 1794 Flex I/O through the Flex D-shell type base modules, 1794TB37DS and 1794-TB62DS. The interface modules are mounted onto a standard DIN #3 Rail. Pre-printed adhesive label cards containing field-wiring information are included for each interface module and I/O module combination. Benefits Reduced Wiring Time PLC I/O module to field device wiring is completed in a fraction of the time when Bulletin 1492 wiring systems are used as compared with the traditional method of wiring each point to the PLC I/O swing arm and field-side terminal blocks. Pre-wired cables are factory-wired to the I/O wiring arm on one end and a connector for the Interface Module (IFM) on the other. IFMs enhance the capability of the I/O systems with added terminations, field-side LED status indicators, isolation circuits, overcurrent protection, and higher amp outputs. Both standard and specific build to order length cables are available, providing the correct length for any panel in a neat, space-efficient wiring solution. Reduced Wiring Errors Wiring system cables are pre-tested to ensure 100% accurate connections and eliminate the need for point-to-point checking of wiring—no more crossed wires and loose connections between the I/O module and the terminal block. Even one error in wiring 128 I/O points in a point-to-point system may require a complete check of the wiring. Wiring errors can take several minutes or hours to track down and correct before the panel is ready for startup. When IFMs and cables are snapped in place, they fit every time — no need to find the wrong or loose connection, resulting in a much higher rate of success at system startup. Faster Troubleshooting and Easier Maintenance Normal terminal blocks can’t offer the benefits of Bulletin 1492 wiring systems, such as LED indication on each I/O point. Wiring systems improve system startup and ease troubleshooting and maintenance. Diagnostic capabilities in the form of fuses, blown fuse indication, and field-side ONPublication 1492-TD008D-EN-P - January 2009 Continued Increased Volume and Productivity Cable interconnections for a Bulletin 1492 wiring system can be up to 30 times faster to install than traditional point-to-point wiring.4 Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems State LEDs — in a reduced space — allow maintenance personnel to quickly locate faults. Preprinted I/O-specific labels ensure neat. reduce downtime. Reduced Wire Preparation and Routing Pre-wired Bulletin 1492 wiring system cables eliminate the time and costs associated with stripping and cutting wires. requiring additional equipment in the form of a plotter system and a PC to run the plotter software. Simplified panel drawings aid both the installer and the end user who receives the panel. since engineers only have to worry about routing one prewired cable versus the 20 or 40 wires needed in the traditional wiring method. For example. Benefits. easy-to-read identification of wires and I/O points for all users. if an OEM were to use a 40-point IFM in place of 40 terminal blocks. as they require less DIN Rail space than traditional terminal blocks. DIN Rail space can be reduced by more than 50%. PLC I/O-specific adhesive label strips for quick marking of IFM module terminals save labor compared with point-to-point wiring that requires labor-intensive wire markers.January 2009 . Labeling and Marking Pre-printed. Pre-wired cables require no wire labels. Publication 1492-TD008D-EN-P . and improve overall productivity. Routing wires is much easier with wiring systems. Simplified Design Design engineers can simplify their panel drawings by calling out an IFM and pre-wired cable instead of having to detail every single wire and terminal block on their drawings. Wiring systems support this trend. The marking of traditional terminal blocks has even caused some OEMs to move toward a high-tech approach of plotting markers. enabling OEMs and panel builders using wiring systems to build panels faster and produce more machines. Increased DIN Rail Density An increasing trend in the industry is to pack more products into the same DIN Rail space. Therefore. barrier.). Rockwell Automation provides the broadest range of digital and analog systems in the industry. Publication 1492-TD008D-EN-P . Continued Increased DIN Rail Density. Design Flexibility To develop a cost-effective system. it requires fewer components and. fusible IFMs.. markers. the hardware components must meet the needs of the design engineer.36 in. wires. Fewer Parts. making them well-suited for tightly packed enclosures.January 2009 . sensor.g. extra terminal. They require 45% less space than the standard length IFMs. which correspond to the I/O module address. The high-density narrow IFMs have two rows of 10 field-wiring terminals with an overall length of 60 mm (2. To further reduce panel space. Continued All IFMs have terminals for connecting the I/O field wiring. versus the block. and swing arms associated with traditional hardwired systems. Catalog Number 1492-IFM20FN) have been designed. No additional terminal blocks are needed to provide power to the sensors/actuators — saving valuable panel/DIN Rail space. less inventory and lower carrying costs. Allen-Bradley Wiring Systems deliver a lower life-cycle cost. Pre-printed adhesive labels for the terminals neatly identify field-wiring connections. jumper. in turn. narrow IFMs (e. Quality-Looking Panels The pre-wired cables and IFM wiring system modules organize the wiring in your panel and provide a consistent look. and relay IFMs contain common terminals that are used as power busses for sensors and actuators. A large marking area is also available for identifying I/O information on the IFM. In addition. Less Inventory and Lower Carrying Cost A wiring system involves an IFM and the cable.Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems 5 Benefits. High-density field-side wiring terminals allow more connections in less space and accommodate #22…12 AWG wire. similar to groups of terminal blocks. NRAQ CE Compliant for all applicable directives Refer to Specifications. All of the digital IFMs have the following features: cULus: Hazardous Locations: Class I Div 2 (all modules. The IFMs are compatible with both the pre-wired cables and the IFM-ready cables. Pre-printed and blank adhesive marking strips are provided to identify either Programmable Controller I/O field-side wiring terminals or your own application requirements. Standard DIN #3 Rail mounting for quick installation.or 40-pin) with locking tabs for easy installation and secure connection of IFM pre-wired and IFM-ready cables. page 191.6 Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems Digital IFM Options and Features Digital IFMs. except those with relays). B. are available with either 20-pin (typically 8 to 16 PLC I/O points) or 40-pin (typically 16 to 32 PLC I/O points) cable connectors. NRAG cULus: Ordinary Locations. UL File No. and D. E10314. Keyed cable connector (20. E113724 Guide No. Digital IFM Publication 1492-TD008D-EN-P .January 2009 . LEDs and fuse clips are available on-board the IFMs to customize your wiring system to your application and provide assistance with troubleshooting your control panel. The number of field-side wiring terminals varies with the type of module — from one to three terminals per I/O point. Groups A. Temperature Code: T3C @ 60 °C. UL File No. Module with relays. Continuous current rating of 2 A per circuit supports higher-current programmable controller output modules. D. Guide No. The extra terminal modules are beneficial in applications in which the I/O devices are terminated within the same panel as the I/O modules — eliminating the need for many additional terminal blocks. Continued Standard Terminal Modules Standard terminal IFM modules provide one field-side wiring terminal per programmable controller input or output point. as well as enough terminals for the I/O module power connections. which allows each group of I/O devices to reference a different power source.January 2009 . IFMs which are not point-to-point isolated have two terminals per input or output point. Extra Terminal Modules Extra terminal modules provide two or four field-side terminals per input or output point. Non-isolated IFMs have the lower row of extra terminals commoned together in groups of 10 ➊. The standard terminal modules are ideal for applications in which the I/O device commons are terminated in the field or remotely from the I/O module panel. Isolated IFMs have terminals isolated into 8 or 16 groups. These modules are also available with optional field-side status LEDs for troubleshooting inputs and outputs. Publication 1492-TD008D-EN-P .Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems 7 Digital IFM Options and Features. which are in groups of 20. ➊ Except Catalog Numbers 1492-IFM20D24A-2 and -IFM20D120A-2. Point-to-point isolated IFMs have two or four terminals per input or output point. to serve as a power bus for the field device commons. The sensor modules provide a compact method of terminating and powering 24V AC/DC or 120V AC (Catalog Number IFM20F-3 only) 3-wire devices.January 2009 . the IFM LEDs can help determine whether a problem resides in the I/O module or field device/wiring. Continued Sensor Modules Sensor modules provide three field-side terminals per input point. and sensor IFMs. The middle and lower rows of terminals. commoned together in groups of 18. The LEDs provide field-side troubleshooting diagnostics: the on/off status of an input device or the on/off status of the programmable controller output circuit.8 Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems Digital IFM Options and Features. LED Modules Voltage-indicating LEDs are available on the standard. The LED modules have unique circuitry that allows compatibility with sinking or sourcing input or output modules. serve as power busses for 3-wire sensor types of devices — eliminating additional terminal blocks and jumpering systems. Publication 1492-TD008D-EN-P . extra terminal. When used in conjunction with the logic-side programmable controller LEDs. Driving large loads up to 10 A for applications such as motor starters is now possible with Bulletin 1492 Wiring Systems. Fusible modules are available in both isolated and non-isolated versions.or 40-pin cable connectors for the pre-wired Bulletin 1492 cable. Publication 1492-TD008D-EN-P . aiding in the removal of a fuse with a fuse puller (fuses are not included). The fusible modules also have two or four terminals per I/O point to create a power bus for input or output load connections.January 2009 . Continued Fusible Modules Fusible modules provide a convenient method of adding overcurrent protection into your programmable controller field wiring. There are a select number of fusible IFMs available for input modules. The fusible modules have an easy-to-remove see-through acrylic cover to prevent objects from contacting fuse circuitry under normal operation. The 24V or 120V blown fuse indicators reduce the troubleshooting time to locate and replace a blown fuse on the IFM.Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems 9 Digital IFM Options and Features. These modules have 5 x 20 mm fuse clips on-board and are available with and without blown fuse indication. The 8 or 16 point Relay Master modules provide the connection for the 20. The Relay and Relay Expander product line consists of a Relay Master module and Expander Module(s) with expander cable. the Relay Modules provide a means to isolate output points. In addition. Relay and Relay Expander Modules Relay and Relay Expander Interface Modules (XIMs) were developed to maximize the effectiveness of users’ applications that require output contact ratings greater than 2 A. Standard fuse holders reside in the IFM. Continued Relay and Relay Expansion Modules. and transient suppression on each coil. 16-point relay masters are available with or without 5 x 20 fuse holders so customers can fuse the output contacts.10 Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems Digital IFM Options and Features. Relay Expanders Relay Expander (16) with Fusing Relay expander XIMs feature eight field-replaceable relays with 120V or 24V rated coils. The Form C relay output provides isolated output channels and a different voltage level from one output channel to the next. The field-side Form C contacts are rated 240V 10 A (de-rated to 12 A per adjacent pair on the XIM). The field-side Form C contacts are rated 240V 10 A (de-rated to 12 A per adjacent pair on the XIM). Other features include coil-side LED indicating the PLC output module status. The Form C relay output provides isolated output channels and a different voltage level from one output channel to the next.January 2009 . Continued Relay Master Relay Master with Fusing Relay master XIMs feature field-replaceable relays with 120V or 24V rated coils. In addition. Publication 1492-TD008D-EN-P . a relay expander can have 5 x 20 fuse holders so customers can fuse the output contacts. An expander cable is provided for connection to the mating module. In addition. Other features include coil-side LED indicating the PLC output module status. and transient suppression on each coil. Publication 1492-TD008D-EN-P . Continued Fusible Expanders The fusible expander modules feature eight 5 x 20 mm finger-safe fuse holders. Feed-Through Expanders The feed-through expander modules feature eight channels with extra terminals for landing two wires per field-side device.January 2009 . and extra terminals for landing two wires per field-side device. They are offered with eight fuse holders for both 24V and 120V applications. Continued Relay and Relay Expansion Modules. An expander cable is provided for connection to the mating module.Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems 11 Digital IFM Options and Features. An expander cable is provided for connection to the mating module. Fuses are not provided. blown fuse indicators. 1492-RTB20N)or push-in style (e.12 Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems Digital IFM Options and Features. Screw-style RTB plug (Order separately) Push-in style RTB plug (Order separately) Publication 1492-TD008D-EN-P . which is mechanically secured to the module circuit board hand housing. Modules are shipped with the RTB socket. All of the features available on fixed terminal block products (e. The removable plug portion of the RTB assembly has a screw at each end to securely fasten it to the RTB socket. but without the removable plug(s).g.g.January 2009 . refer to page 17 for details). 1492-RTB16P) terminals and must be ordered separately (two pieces cat. Refer to the selection tables for the particular PLC I/O system of interest to determine which modules are offered with field removable terminal blocks.. or where hand-access is limited. labels. It can also provide easier and faster replacement of a damaged or defective Bulletin 1492 wiring system module.. fused and relay digital Bulletin 1492 wiring system modules (refer to Selection Tables) have field terminal blocks that can be removed (RTB). etc.) are also provided for the removable terminal block Bulletin 1492 wiring system modules. Continued Digital IFM Modules with Field Removable Terminal Blocks (RTBs) Select groups of standard. agency certification. no.g.. Plugs are available with screw style (e. This RTB feature can provide easier wiring of field devices in a control cabinet where the IFM is located in a hard to reach area. 1794 Flex.0. Other cable lengths are also available as build-to-order products. The digital pre-wired cables are offered in four standard lengths of 0.5. 2. and 1771 I/O modules. All of the pre-wired cables use #22 AWG wire and are 100% tested for continuity to make a perfect connection every time. Most I/O-ready cables use #18 AWG conductors for higher current applications or longer cable runs. Digital I/O Publication 1492-TD008D-EN-P .5. replace the point-to-point wiring between Allen-Bradley programmable controller I/O modules and individual terminal blocks.0. Ready-to-Wire Digital Cables Digital I/O Module-Ready Cable and Standard Terminal Block Digital I/O module-ready cables have an I/O removable terminal block or wiring arm pre-wired to one end to of the cable and free connectors on the other end for wiring into standard terminal blocks or other type of connectors. Pre-wired cables are available for many of the Bulletin 1756 ControlLogix. 2. The I/O-ready cables are offered in standard lengths of 1. The pre-wired cables have a removable terminal block or wiring arm at the I/O end of the cable and a cable connector on the other end to connect to the IFM. and 5.Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems 13 Digital IFM Options and Features. Plus availability for the base I/O of the MicroLogix 1500 and 40 I/O base of the MicroLogix 1200 packaged controllers. Continued Digital Pre-Wired Cables Pre-Wired Cable and Interface Module Bulletin 1492 pre-wired cables are designed to minimize control wiring in a panel.0 m to fit a variety of applications. 1769 Compact I/O used with CompactLogix and MicroLogix 1500.January 2009 .0 m to fit a variety of applications. A select group of modules are also available for the PowerFlex 700H and 700S drives. I/O-ready cables have individual color-coded conductors for quick wire-toterminal coordination. when used with an IFM. Pre-wired cables. 1. and 5. Other cable lengths are also available as build-to-order products.5. and 1771 I/O modules. use this breakdown for verification and explanation only. Digital IFM Options and Features. Continued Ready-to-Wire Digital Cables. 2. It is not a product configurator.5. Other cable lengths are also available as build-to-order products.0 m to fit a variety of applications. Plus availability for the base I/O of the MicroLogix 1500 and 40 I/O base of the MicroLogix 1200 packaged controllers. First. IFM Catalog Number Explanation for Digital I/O Modules Important: The following IFM catalog number breakdown is for explanation purposes only. 1769 Compact I/O used with CompactLogix and MicroLogix 1500.January 2009 . The digital IFM-ready cables are offered in standard lengths of 1. and 5. Publication 1492-TD008D-EN-P . select the desired IFM using the steps in Ordering Digital and Analog Wiring Systems on page 28. Continued IFM-Ready Cable and Interface Module IFM-ready cables have a cable connector that attaches to the IFM pre-wired to one end and free connectors ready to wire to I/O modules or other components on the other end. Then.14 Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems module ready cables are available for many of the Bulletin 1756 ControlLogix. 1794 Flex. IFM-ready cables use #22 AWG wire and have individual color-coded conductors for quick wire-to-terminal coordination. Not all combinations of fields are valid product catalog numbers.0. A select group of modules are also available for the PowerFlex 700H and 700S drives. Digital Interface Modules IFM Fixed (non-removable) terminal block RIFM Removable terminal block No.Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems 15 1492– IFM 20 F– F120– 2 Bulletin No. of Field-Side Wiring Terminals Blank One per I/O connection 2 Two per I/O connection 3 Three per I/O connection 4 Four per I/O connection No.January 2009 . of Cable Connector Pins 20 20 pins 40 40 pins Status Indication F No LEDs FN Narrow IFM D24 24V AC/DC LEDs for input and output modules D24N Narrow IFM with 24V AC/DC LEDs D24A 24V AC/DC LEDs for input modules DS24 Isolated IFM with 24/48V AC/DC LEDs for output modules DS24A Isolated IFM with 24V AC/DC LEDs for input modules D120 120V AC LEDs for input and output modules D120N Narrow IFM with 120V AC LEDs D120A 120V AC LEDs for input modules DS120 Isolated IFM with 120V AC LEDs for output modules DS120A Isolated IFM with 120V AC LEDs for input modules D240 240V AC LEDs for output modules DS240A Isolated IFM with 240V AC LEDs for input modules D240A 240V AC LEDs for input modules Fuses and Their Indicators Blank No fuse clips F 5 x 20 mm fuse clips F24 5 x 20 mm fuse clips with 24V blown fuse indicators for output modules F24A 5 x 20 mm fuse clips with 24V blown fuse indicators for input modules F120 5 x 20 mm fuse clips with 120V blown fuse indicators for output modules F120A 5 x 20 mm fuse clips with 120V blown fuse indicators for input modules F240 5 x 20 mm fuse clips with 240V blown fuse indicators for output modules F24D-2 5 x 20 mm fuse clips with 24V blown fuse low leakage indicators for the 1756-OB16D diagnostic output module F24AD-4 5 x 20 mm fuse clips with 24V blown fuse low leakage indicators for the 1756-IB16D diagnostic input module FS Isolated IFM with 5 x 20 mm fuse clips FS24 Isolated IFM with 5 x 20 mm fuse clips with 24V blown fuse indicators for output modules FS24A Isolated IFM with 5 x 20 mm fuse clips with 24V blown fuse indicators for input modules FS120 Isolated IFM with 5 x 20 mm fuse clips with 120V blown fuse indicators for output modules FS120A Isolated IFM with 5 x 20 mm fuse clips with 120V blown fuse indication for input modules FS240 Isolated IFM with 5 x 20 mm fuse clips with 240V blown fuse indication for output modules Publication 1492-TD008D-EN-P . 1756. Expander XIM — In addition to the relay master XIM. Relay Master/Expander XIMs Catalog Number Explanation for Digital I/O Modules Important: The following XIM catalog number breakdown is for explanation purposes only. Relays or Extra Terminals 2 2 terminals per point 8R 8 relays 16R 16 relays 16RF 16 fused relays Relay Master and Expander Interface Modules XIM Fixed (non-removable) terminal block RXIM Removable terminal block No. eight-channel fusing.January 2009 . select the desired XIM using the steps in Ordering Digital and Analog Wiring Systems on page 28.16 Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems Terms for Relay Master/Expander IFMs Relay master and expander XIMs are available for Bulletin 1746. an expander XIM provides eight or sixteen additional outputs. Relay Master XIM — Provides 8 or 16 relay outputs for a digital output module. Cable Connector Pins 20 20 pins (master only) 40 40 pins (master only) Blank Expander module Rating of Relay Coil or Blown Fuse Indicator 24 24V relay coil 120 120V relay coil F No relays or fuses F-F24 5 x 20 mm fuse clips with 24V blown fuse indicators F-F120 5 x 20 mm fuse clips with 120V blown fuse indicators Publication 1492-TD008D-EN-P . and 1771 digital output modules. 1769. 1492– XIM 20 24– 2 Bulletin No. No. Then. It is not a product configurator. use this breakdown for verification and explanation only. There are five types of expander XIMs: eight-channel relays. and eight-channel feedthrough XIMs. Not all combinations of fields are valid product catalog numbers First. Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems 17 Removable Terminal Block (RTB) Plug Catalog Number Explanation Important: The following RTB plug catalog number breakdown is for explanation only. Connector Style N Screw Style P Push-in Style Removable Terminal Block Plug Number of Poles/ Terminals 8 12 14 16 17 20 Publication 1492-TD008D-EN-P .January 2009 . 1492– RTB 20 – N Bulletin No. E. C. All combinations of these fields make valid product catalog numbers.0…10.1…2.and 16-point digital Bulletin 1756 I/O modules ➌ Y.0 m (3.28 ft) 025 2. 1756. D. refer to pages 59.64 ft) Standard Length 010 1. Cable Type A. ➋ To make sure the Bulletin 1771 PLC digital I/O module is compatible with the IFM/XIM.5 m (8. refer to pages 36.January 2009 . Refer to selection tables for IFM/XIM compatibility and ordering.328…6. G. and 34. K. R Pre-wired cables for 16-point isolated and 32-point digital Bulletin 1771 I/O modules ➋ U. N. T FF Digital Interface Cable Standard or Build-to-Order Length Cable 005 0.5 m (1. and 62. B. Z Pre-wired cables for 16-point isolated and 32-point digital Bulletin 1756 I/O modules ➌ P Digital IFM-ready cable with 20 conductors Q Digital IFM-ready cable with 40 conductors N3 Digital I/O module-ready cable with 40-point Catalog Number 1746-N3 cable connector RTBB Digital I/O module-ready cable with 16-point Catalog Number 1746-RT25B terminal block (blue) RTBO Digital I/O module-ready cable with 16-point Catalog Number 1746-RT25C terminal block (orange) RTBR Digital I/O module-ready cable with 16-point Catalog Number 1746-RT25R terminal block (red) TBCH Digital I/O module-ready cable with 36-pin Catalog Number 1756-TBCH removable terminal block TBNH Digital I/O module-ready cable with 20-pin Catalog Number 1756-TBNH removable terminal block WA Digital I/O module-ready cable with Catalog Number 1771-WA 8-point wiring arm WD Digital I/O module-ready cable with Catalog Number 1771-WD 6-point wiring arm WH Digital I/O module-ready cable with Catalog Number 1771-WH 16-point wiring arm WHF Digital I/O module-ready cable with Catalog Number 1771-WHF 16-point fused wiring arm WN Digital I/O module-ready cable with Catalog Number 1771-WN 32-point wiring arm ➊ To make sure the Bulletin 1746 SLC 500 digital I/O module is compatible with the IFM/XIM.64 ft) increments 100… 10. 31.56…32. 38. which uses the 1492-CABLE*CR cable. refer to pages 29. ➌ To make sure the Bulletin 1756 ControlLogix digital I/O module is compatible with the IFM/XIM.28 ft) increments Pre-wired cables for 8-point isolated and 16-point digital Bulletin 1746 I/O modules ➊ Pre-wired cable for Catalog Number 1746-OA16 (XIM only) Pre-wired cable for digital Bulletin 1771 I/O modules ➋ Pre-wired cable with fused wiring arm for 16-point digital Bulletin 1771 output modules ➋ H Pre-wired cable for 32-point digital Bulletin 1746 I/O modules ➊ J. W. L.4 ft) 300 1.328 ft) increments Length 020… 2. IFM-ready.40 ft) 001… 0. The cables used for Relay Master/Expander XIMs are the same as those used for Digital I/O Modules (page 28) with the exception of the Catalog Number 1746-OA16 output module.8 ft) 100 0. V. and 1771 digital I/O module cables. and I/O module-ready cables for Bulletins 1746. and 40.0 m (6. X Pre-wired cables for 8.8…98. 1492– CABLE 010 A Bulletin No.0 m (0. M.5 m (1.0 m (16.56 ft) Build-to-Order 020 0.1 m (0. S CR F.0…30.18 Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems IFM and XIM Cable Catalog Number Explanation for Digital I/O Modules Important: Use the following tables as a product configurator for pre-wired.0 m (3. 60.20 ft) 050 5.0 m (32. Publication 1492-TD008D-EN-P . January 2009 .20 ft) 050 5.8…98.28 ft) increments Standard Length Build-to-Order Length Publication 1492-TD008D-EN-P .5 m (1. L69.40 ft) 001-020 0.8 ft) 0. Pre-wired cables for 8.Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems 19 IFM and XIM Cable Catalog Number Explanation for Digital I/O Modules.4 ft) 1. C69.5 m (1. Bulletin 1769 digital I/O modules G69.5 m (8.0…10. Continued Important: Use the following tables as a product configurator for pre-wired. Cable Type A69.328 ft increments) 020-100 2.28 ft) 025 2. and I/O module-ready cables for Bulletins 1769 digital I/O module cables.56…32. Refer to selection tables for IFM/XIM compatibility and ordering. All combinations of these fields make valid product catalog number. 1492– CAB 010 A69 Bulletin No.0…30. 16. Digital Interface Cable Standard or Build-to-Order Length Cable 005 0.0 m (6.64 ft) 010 1.0 m (0. F69. see pages 59 and 60.56 ft) 0. J69. E69. M69 RTN10 I/O-ready cable with Catalog Number 1769-RTBN10 terminal block RTN18 I/O-ready cable with Catalog Number 1769RTBN18 terminal block RTN32I I/O-ready cable for 1769-IQ32 module RTN32O I/O ready cable for 1769-OB32 module R71 Pre-wired cables for 16-channel isolated and 32-channel digital Bulletin 1771 I/O modules ➊ ➊ To make sure the Bulletin 1771 PLC analog I/O module is compatible with the IFM. K69.64 ft) increments 100-300 10.0 m (32. and 32-point D69.1 m (0.1…2. IFM-ready.0 m (3.328…6.0 m (3. H69. B69.0 m (16. All combinations of these fields make valid product catalog number.28 ft) increments Cable Type A94 B94 Pre-wired cables for Bulletin 1794 Flex digital I/O using the Bulletin 1794-TB37DS base Pre-wired cables for Bulletin 1794 Flex digital I/O using the Bulletin 1794-TB62DS base Digital I/O ready cable for digital I/O using the Bulletin 1794 TB37DS base Digital I/O ready cable for digital I/O using the Bulletin 1794 TB62DS base Standard Length G94 H94 Build-to-Order Length Publication 1492-TD008D-EN-P . and 1794-TB62DS base units.5 m (1.328 ft increments) 020-100 2. Refer to selection tables for IFM compatibility and ordering.0…30.0 m (3.56…32.56 ft) Build-to-Order 020 0.328 ft) increments Length 020… 2.1 m (0. and I/O module-ready cables for Bulletin 1764 MicroLogix 1500 and 1762 MicroLogix 1200 40 I/O controller digital I/O cables.1…2.0 m (16.56 ft) 0. Nos. and I/O module-ready cables for Bulletin 1794 Flex I/O.4 ft) 1.0 m (0. -24BWA base unit inputs X64 I/O-ready cable 1764-28BXB base unit inputs T64 I/O-ready cable for1764-24AWA.0 m (32.328…6.8 ft) 0.8…98.0 m (6.0 m (0.28 ft) increments Cable Catalog Number Explanation for 1794 Flex I/O to IFM Modules Important: Use the following tables as a product configurator for pre-wired.0…10. -L40BXB.40 ft) 001… 0.56…32.0 m (32.5 m (1.0…30.8…98.0 m (16.5 m (8.1…2. Important: Use the following tables as a product configurator for pre-wired.0 m (3.5 m (8. 1492-CAB010A62 A62. 1492-CAB010A64 A64. F64 Pre-wired cables for Bulletin 1764 I/O base units W64 I/O-ready cable for 1764-24AWA. 1492– CAB 010 A6x Digital Interface Cable Cable Type for Bul.64 ft) Standard Length 010 1.28 ft) 025 2. All combinations of these fields make valid product catalog numbers.20 Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems Cable Catalog Number Explanation for µ1200 and µ1500 Base I/O to IFM Modules Bulletin No. C64. and -L40BWA inputs T62 I/O-ready cable for 1762-L40AWA. -L40BXB and -L40BWA outputs Cable Type for Bul.0…10. B62 Pre-wired cables for Bulletin 1762 40 I/O controllers X62 I/O-ready cable for 1762-L40AWA.4 ft) 300 1.64 ft) increments 100… 10.5 m (1.64 ft) 010 1.40 ft) 001-020 0.20 ft) 050 5.0 m (6.28 ft) 025 2.0 m (3. B64.328…6.5 m (1. -24BWA base unit outputs U64 I/O-ready cable for 1764-28BXB base unit outputs Standard or Build-to-Order Length Cable 005 0.1 m (0. 1794TB37DS.January 2009 .0 m (3.64 ft) increments 100-300 10. Digital Interface Cable Standard or Build-to-Order Length Cable 005 0. Refer to selection tables for IFM compatibility and ordering.8 ft) 100 0. 1492– CAB 010 A94 Bulletin No.20 ft) 050 5. Cat. Metal polarized D-shell connector (15. The shield terminals are internally bussed together and also tied to the D-shell housing to connect with the Bulletin 1492 cable shield and back to the PLC module. and D.or 25-pin) for easy installation. Pre-printed and blank adhesive marking strips are provided to identify either Programmable Controller I/O field-side wiring terminals or your own application requirements.3000590 CE Compliant for all applicable directives Refer to Specifications. E10314. Class I Div 2: Groups A. page 191.I. The number of field-side wiring terminals varies with the type of module — from three to five terminals per analog I/O channel. B. AIFMs are available as feed-through or fusible to customize the wiring system to your application. All of the AIFMs have the following features: cULus: Hazardous Locations: Class I Div 2. High-density field-side wiring terminals allow more connections in less space and accommodate #22…12 AWG wire.January 2009 . Simply flip a DIP switch to add the 250 Ω series impedance into the output circuit. and D. Some feed-through AIFMs also have special features (refer to page 26). UL File No. As a troubleshooting aid.Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems 21 Analog IFM Options and Features Analog IFMs (AIFMs). Temperature Rating: T3C @ 60 °C. Pre-wired cable has mating D-shell connector with slidelocking mechanism for secure connection. B. when used with Catalog Numbers 1771-OFE2 and -OFE3 analog input modules. C.or 25-pin D-shell connectors. D. Temperature Code: T3C @ 60 °C. provides selectable current limiting resistors. NRAG Factory Mutual (FM): Hazardous Locations. test point loops access the circuit on either side of the series resistor and can be used to Publication 1492-TD008D-EN-P . FM file J. Provides the facility for continuous shield. Standard DIN #3 Rail mounting for quick installation. Analog IFM Continuous current rating of 2 A per circuit supports higher-current programmable controller output modules. The Catalog Number 1492-AIFM4-3 AIFM. are available with either 15. Analog Feed-Through Modules Feed-through AIFMs have three terminals per analog I/O channel to wire the analog I/O device connections and shield. similar to groups of terminal blocks. Guide No. Groups A. 1756 thermocouple module to adjust the input value. Isolation switch Publication 1492-TD008D-EN-P . 4-Wire Transmitter Input AIFM 1+ Power Supply Transmitter 1Channel 1SHIELD = AIFM Field Terminal Analog Input Module Pre-wired Cable Channel 1+ Output AIFM 0 LOAD Pre-wired Cable OUT 0 C ANL COM SH Analog Output Module Analog Fusible Modules Fusible AIFMs are available for analog input modules. The fuse holder has an integrated fuse puller to simplify fuse removal. The Catalog Number 1492-AIFM8-3 AIFM has eight extra terminals commoned together in a power bus that can be used for Module Common connections or power supply connections.or off-board cold junction compensation to allow thermocouples to be connected “remotely” while still correcting for temperature at the termination point. The extra terminals and internal jumpering eliminate the need for some terminal blocks for power connections and jumper accessories. Below are examples of the field-side connections available on the feed-through AIFMs. The field-side power source is distributed through individual on-board 5 x 20 mm fuse clips. Nos. These AIFMs enable you to fuse the input device power source on the field-side. 1756-IT6I and 1756-IT6I2 controllers provide on.22 Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems measure output circuit voltage/current.January 2009 . The limiting resistors are configured on a per channel basis. The Catalog Number 1492-AIFM6TC-3 AIFM for the Cat. The combination thermistor and isothermal bar acquires temperature data at the AIFM for the Bul. The fused AIFMs have 24V DC blown fuse indicators to reduce the troubleshooting time needed to locate and replace a blown fuse. once the circuit has been isolated and power restored. 1756. depending on the AIFM) that can be used for +V and DC COM connections and/or device Common. The extra terminals and internal connections eliminate additional terminal blocks and jumpers — reducing spare parts inventory. device shield. and power connections for 2-. page 184) are also available to isolate an input circuit after power is removed. The Catalog Numbers 1492-AIFM4I-F-5 and 1492-AIFM4C-F-5 AIFMs both have test point loops on either side of the fuse clips for easier access and connection of metering equipment. 2-Wire Analog Input Transmitter AIFM +V Power Supply Transmitter V1 Analog Input Module 1+ SHIELD 1Channel 1VCOM = Fuse = AIFM Field Side Terminal Pre-wired Cable Channel 1+ Publication 1492-TD008D-EN-P . and 1771 analog input modules. Several of the fusible AIFMs have on-board DIP switches to easily connect unused inputs to module common — reducing wiring on the field-side.and 4-wire transmitters available on the fusible AIFMs. and 4-wire transmitters. In addition. 3-. the input loop current can be measured in 2-wire transmitter applications. which has three terminals per channel) to wire the input-device connections. Below are several examples of the field-side connections for 2. You no longer need extra jumper wires or comb-style jumpers to properly terminate unused inputs.January 2009 . There are two separate power busses (4…16 terminals. Metering equipment can also be attached to the fuse clips on other AIFMs for measuring input loop current. and simplifying installation. Inputs are jumpered via DIP switch on a perchannel basis. saving panel space. The shield terminals are internally bussed together and also tied to the D-shell housing to connect with the Bulletin 1492 cable shield and back to the PLC module.Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems 23 plugs or “dummy fuses” (refer to Accessories. as recommended on many Bulletin 1746. The fusible AIFMs have five terminals per input channel (except Catalog Number AIFM16-F-3. It can also provide easier and faster replacement of a damaged or defective Bulletin 1492 wiring system module. labels. but without the removable plug(s). Modules hare shipped with the RTB socket.g.com. All of the features available on analog fixed terminal block products (e. Analog AIFM Modules with Field Removable Terminal Blocks (RTBs) Select groups of analog Bulletin 1492 wiring system modules (refer to Selection Tables) have field terminal blocks that can be removed (RTB). Refer to the Selection Tables for the particular PLC I/O system of interest to determine which modules are offered with field Removable Terminals Blocks.ab. which is mechanically secured to the module circuit board and housing. This RTB feature can provide easier wiring of field devices in a control cabinet where the IFM is located in a hard to reach area. Refer to page 186. Plugs are available with screw style or push-in style terminals and must be ordered separately. Publication 1492-TD008D-EN-P . etc.24 Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems 4-Wire Analog Input Transmitter AIFM +V Power Supply V1 Analog Input Module 1+ Transmitter 1Channel 1SHIELD VCOM Pre-wired Cable Channel 1+ Note: Bulletin 1492 module wiring diagrams are available at www. The removable plug portion of the RTB assembly has a screw at each end to securely fasten it to the RTB socket. or where hand-access is limited.) are also provided for the removable terminal block Bulletin 1492 wiring system modules. agency certification.January 2009 . Publication 1492-TD008D-EN-P .Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems 25 RTB Socket Screw style RTB Plug (Order Separately) 2 per cat. no. Push-in style RTB Plug (Order Separately) 2 per cat. no.January 2009 . select the desired AIFM using the steps in Ordering Digital and Analog Wiring Systems on page 28. use this breakdown for verification and explanation only. Then. output.26 Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems AIFM Catalog Number Explanation for Analog I/O Modules Important: The following AIFM catalog number breakdown is for explanation purposes only.January 2009 . 1492– AIFM 16– F– 5 Bulletin No. Field-Side Wiring Terminals 3 3 per I/O channel 5 5 per input channel Analog Interface Modules AIFM Fixed (non-removable) terminal block RAIMF Removable terminal block No. Analog I/O Channels 4 4 channels: input. No. It is not a product configurator. Not all combinations of fields are valid product catalog numbers First. or 2 input/output combination 4C 4 channels: 2 input/2 output combination 4I 4 input channels 6S 6 isolated input or output channels 6TC 6 thermocouple input channels 8 8 input or output channels 16 16 input channels PI 8 input/2 output channels CE4 2-channel counter input/4 outputs Input Fuse Clips and Blown Fuse Indicators Blank No fuse clips F 5 x 20 mm fuse clips with 24V DC blown fuse indicators for output modules Publication 1492-TD008D-EN-P . 1 m (0.56…32. and 1771 Analog I/O Modules Bulletin No.40 ft) 001-020 0.28 ft) 025 2. CC69.5 m (8. Pre-wired cables for Bulletin 1746 analog I/O and K. select the desired AIFM using the steps in Ordering Digital and Analog Wiring Systems on page 28. TB.0 m (3.0…30. All combinations of fields are not valid product catalog numbers.4 ft) 1. HA69 Z7H Pre-wired cable for PowerFlex 700H X7S.328 ft increments) 020-100 2. 1769.0 m (0.8…98. BB69.328 ft increments) 020-100 2. BC69. First.64 ft) 010 1.328…6. CA69. use this breakdown for verification and explanation only.0…10.56…32.28 ft) 025 2.64 ft) increments 100-300 10. D69.328…6. M Pre-wired cables for Bulletin 1757 pulse input module.Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems 27 Pre-Wired Cable Catalog Number Explanation for Bulletins 1746. All combinations of fields are not valid product catalog numbers.4 ft) 1. Z.January 2009 .0 m (3. WA. It is not a product configurator.28 ft) increments Standard Length Build-to-Order Length A-Cable Type A. and -IT6I thermocouple input modules. L.56 ft) 0.0…10. Y.0 m (16. Pre-Wired Cable Catalog Number Explanation for Bulletin 1746.0 m (32. Q. 1492– ACABLE 050 A Analog Interface Cables Standard or Build-to-Order Length Cable 005 0. G.0…30. D.40 ft) 001-020 0. UD.5 m (1. TA. C69.20 ft) 050 5.28 ft) increments Cable Type A46 Standard Length Build-to-Order Length AA69. EB69. X. TD.1 m (0.8 ft) 0. AB69.5 m (8. VA.5 m (1. VB. UC.56 ft) 0. 1756.0 m (16. UA.8 ft) 0. J Pre-wired cables for Bulletin 1771 analog I/O and RTD input modules.20 ft) 050 5. Pre-wired cables for Bulletin 1769 analog I/O modules and RTD input module. E.0 m (30. Then.0 m (6. TC.5 m (1. Important: The following analog cable catalog number breakdown is for explanation purposes only. First. EC69. BA69. ZB.0 m (0.0 m (3. Analog Interface Cables Standard or Build-to-Order Length Cable 005 0. ED69. Pre-wired cables for Bulletin 1756 analog I/O. R RTD input modules.64 ft) 010 1.0…98. It is not a product configurator. UB. B. H.1…2. ZA. WB. select the desired AIFM using the steps in Ordering Digital and Analog Wiring Systems on page 28.0 m (6. and PowerFlex Analog I/O Modules Important: The following analog cable catalog number breakdown is for explanation purposes only. F.64 ft) increments 100-300 10.0 m (3. CB69. C. EA69. 1794. Z7S Pre-wired cables for PowerFlex 700S Z94 Pre-wired cables for Bulletin 1794 analog I/O modules Pre-wired cables for Bulletin 1746-NI16I and -NI16V analog modules. ZC YT Pre-wired cable for bulletin 1756-IT6I2 thermocouple input Module. use this breakdown for verification and explanation only. P.1…2. RTD. Publication 1492-TD008D-EN-P .5 m (1. BD69. 1492– ACAB 005 A46 Bulletin No. Then. January 2009 . 1756.. Determine your field-side wiring requirements. Publication 1492-TD008D-EN-P .0 m. Are extra terminals needed? 4. 5. Determine your desired PLC I/O module to IFM/XIM/AIFM cable length (0. 2. 1769. 3. 29 35 36 41 43 45 52 53 58 59 63 66 Ordering Digital IFM-Ready Cables for IFMs/XIMs (Refer to page 14 for definition of IFM-ready) For pinout and wiring information. Determine the PLC or PowerFlex I/O platform (e.g. Determine whether you require field-side LEDs. or relays (check voltage ratings for LEDs. 1.700S) you are using and the catalog number of the I/O module being specified (e. or build-to-order) based on wiring needs.. and coil voltage). 1746-IB16). 1771.5 m. 5. relay. Bulletin 1746. fusing for over-current protection. fuse blown indication.g. Refer to selection tables as follows: Selection Table Quick Reference Platform Bulletin 1746 Digital (IFM/XIM) Bulletin 1746 Analog (AIFM) Bulletin 1756 Digital (IFM/XIM) Bulletin 1756 Analog (AIFM) Bulletin 1762/1764 Bulletin 1769 Digital (IFM/XIM) Bulletin 1769 Analog (AIFM) Bulletin 1794 (IFM/XIM) Bulletin 1794 (AIFM) Bulletin 1771 Digital (IFM/XIM) Bulletin 1771 Analog (AIFM) Bulletin 700 PowerFlex Page No.0 m.5 m. 1794. 700H. 2.28 Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems Ordering Digital and Analog Wiring Systems To order the proper IFM/XIM/AIFM pre-wired cable: 1. refer to IFM-Ready Cable Specifications on page 138 and the selection table on page 65. 3-wire sensor type input devices 132V AC/DC Max. If there is no letter code. NOTE: The letter codes designate the compatible Bulletin 1492 cable for that 1746 I/O and Bulletin 1492 Wiring System Module combination. Bulletin 1746 SLC 500 IFMs and Cables Bulletin 1746 Digital 16-Point and 8-Point Isolated I/O Modules ➋ scOAP81➌ A A sc-IA8I➌ sc-IB8I➌ B B Description of 20-PIN IFM Cat. for Wiring System Module with Fixed Terminal Block Cat. Select the desired Bulletin 1492 Wiring System Module. Find the column for the 1746 I/O module. See footnote ➊ on pages 34 and 35. 2. Publication 1492-TD008D-EN-P . the following information is required: • Type of connector needed for the I/O module(s) (catalog number of the wiring arm or removable terminal block). No.5 m – 050 = 5. Find the appropriate table based on the catalog numbers of the 1746 I/O module. for Wiring System I/O Module Catalog Number 1746-… Module with Removable Terminal Block Socket Assembly (order plugs separately) ITB16 IM16 IN16 IA16 IB16 IG16 IH16 IC16 Feed-through Standard 264V AC/DC Max.0 m – Build-to-order length Selection Tables Using Bulletin 1746 Selection Tables to Make Valid Bulletin 1492 Wiring System Module Catalog Numbers Follow these steps when using the selection tables to make valid catalog numbers: 1. No. 3. Narrow standard 132V AC/DC Max.0 m – 025 = 2. • Code for the desired cable length: – 010 = 1. Configure the cable catalog number using 1492-CABLE➊ (for digital cables) or 1492-ACABLE➊ (for analog cables). Follow the column down to determine which Wiring Systems Modules are compatible with the I/O module as indicated by letter code. LED Indicating Standard with 24V AC/DC LEDs Narrow standard with 24V AC/DC LEDs 1492-IFM20D24 1492-IFM20D24N — — — — B B — — — — — — — — B B B B B B B B — — E E E E E E — E E D — — — — — 1492-IFM20F 1492-IFM20FN 1492-IFM20F-2 1492-IFM20F-3 1492-RIFM20F➐ 1492-RIFM20FN➑ 1492-RIFM20F-2➐ — A A A A B B B B B B B B E E E E B B B B A — A — B B B B B B B B B B B B B B B B C G C E E E E E E E E E E E E E E E E E E D N D N A A B B D — — — — — — — — — — — — — — — — — — — — — N — — — — — Note: Footnotes are on page 31.Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems 29 Ordering Digital I/O Module-Ready Cables (Refer to page 13 for the definition of I/O module-ready cables) To order the proper digital I/O module-ready cable. the Bulletin 1492 Wiring System Module is not compatible with the I/O module. 4. 5. Extra terminals (2 per I/O) 264V AC/DC Max.January 2009 scIC8I➌ OBP16 OVP16 OB16E OW16 ITV16 OA16 OB16 OG16 OV16 IV16 OX8 . 30 Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems Bulletin 1746 Digital 16-Point and 8-Point Isolated I/O Modules (Continued)➋ scOAP81➌ A A Description of 20-PIN IFM Cat. Publication 1492-TD008D-EN-P . for Wiring System Module with Fixed Terminal Block 1492-IFM20D120 ➍ 1492-IFM20D120N 1492-IFM20D24-2 1492-IFM20D24A-2 1492-IFM20D120-2 1492-IFM20D120A-2 1492-IFM20D24-3 1492-IFM20DS24-4 Cat. No. for Wiring System I/O Module Catalog Number 1746-… Module with Removable Terminal Block Socket Assembly (order plugs separately) ITB16 IM16 IN16 IA16 IB16 IG16 IH16 IC16 — — — — — — — — A — — — B sc-IA8I➌ sc-IB8I➌ Standard with 120V AC/DC LEDs Narrow standard with 120V AC LEDs 24V AC/DC LEDs and extra terminals for outputs 24V AC/DC LEDs and extra terminals for inputs 120V AC LEDs and extra terminals for outputs 120V AC LEDs and extra terminals for inputs 3-wire sensor with 24V AC/DC LEDs 8 Individually isolated with 24/48V AC/DC LEDs and 4 terminals/output 8 Individually isolated with 120V AC LEDs and 4 terminals/output 240V AC LEDs and extra terminals for outputs 240V AC LEDs and extra terminals for inputs Fusible 120V AC/DC with Extra terminals for outputs Extra terminals with 24V AC/DC blown fuse LED indicators Extra terminals with 120V AC/DC blown fuse LED indicators Extra terminals with 240V AC/DC blown fuse LED indicators Extra terminals with 24V AC/DC blown fuse LED indicators for inputs Extra terminals with 120V AC/DC blown fuse LED indicators for inputs 8 Individually isolated 120V AC/DC with extra terminals for outputs 8 Individually isolated with extra terminals output. No. and 120V AC/DC blown fuse LED indicators 8 Individually isolated with 1492-IFM20F-FS120-4 four terminals/output and 120V AC/DC blown fuse LED indicators Two 4-point isolated groups 1492-IFM20F-FS120A-4 with four terminals/input and 120V AC/DC blown fuse indicators 8 Individually isolated with 1492-IFM20F-FS240-4 four terminals/output and 240V AC/DC blown fuse LED indicators — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — S — — — — — — — — — — — — — — — — — — — — — — S — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — S — — — Note: Footnotes are on page 31. and 24V AC/DC blown fuse indicators — — — — — C — — — — — — D — — — — — A — — — — — — — — — G — — — — — — N — — — — — E E E — E E D — — — — — — — — — — — — — — — — — B — — — — B B B B — — — — — — — — — — — — — C — — — — — — D — — — — — — — — — — — — — — — S — — — — — — — — — — — — — — A — — — — — — — — — — — — — — — — — B — — — — B B B B — — — — — — — — — — — — — — — — — — — — — — — — — 1492-IFM20DS120-4 — — — — — — — — — — — — — — — — — — — S — — — — 1492-IFM20D240-2 1492-IFM20D240A-2 — — — — — — — — — — — — — — — — — C — — — — — — D — — — — — A — — — — — — — — — — — — — — — — — 1492-IFM20F-F-2 1492-IFM20F-F24-2 1492-RIFM20F-F-2➐ 1492-RIFM20F-F24-2➐ — — — — — — — — — — C E E E E E E — — E E E E D — — — — — D — — — — — — — — — — — — — — — — 1492-IFM20F-F120-2 1492-RIFM20F-F120-2➐ — — — — — — — — — — C — — — — — — D — — — — — 1492-IFM20F-F240-2 — — — — — — — — — — — C — — — — — — D — — — — — 1492-IFM20F-F24A-2 1492-RIFM20F-F24A-2➐ — B — — — — B B — — — — — — — E E — — — — — — 1492-IFM20F-F120A-2 1492-RIFM20F-F120A-2➐ A — — — B — — — — — — — — — — — — — — — — — — 1492-IFM20F-FS-2 — — — — — — — — — — — — — — — — — — — S — — — — 1492-IFM20F-FS24-2 — — — — — — — — — — — — — — — — — — — S — — — — Two 4-point isolated groups 1492-IFM20F-FS24A-4 with four terminals/input and 24V AC/DC blown fuse LED indicators 8 Individually isolated with 1492-IFM20F-FS120-2 extra terminals output.January 2009 scIC8I➌ OBP16 OB16E OVP16 OW16 ITV16 OA16 OB16 OG16 OV16 IV16 OX8 . Publication 1492-TD008D-EN-P . for Wiring Cat. Extra terminals132V AC/DC Max. ➑ Compatible Removable Terminal Block (RTB) plug. 3-wire sensor type input devices 60V AC/DC Max. ➏ The LED indicates the PLC output status. No. Example: Catalog Number 1492-CABLE050A is for a 5. ➐ Compatible Removable Terminal Block (RTB) plug. for Wiring System I/O Module Catalog Number 1746-… Module with Removable Terminal Block Socket Assembly (order plugs separately) ITB16 IM16 IN16 IA16 IB16 IG16 IH16 IC16 sc-IA8I➌ sc-IB8I➌ Relay Master (LED Indicating)➎➏ 20-pin master with eight (8) 24V DC relays 20-pin master with eight (8) 120V AC relays 20-pin master with sixteen (16) 24V DC relays 20-pin master with sixteen (16) 24V DC relays with fusing 20-pin master with sixteen (16) 120V AC relays 20-pin master with sixteen (16) 120V AC relays with fusing Expander with eight (8) 24V DC relays Expander with eight (8)120V AC relays Fusible Expander 8-ch. and the letter A. insert the code for the desired cable length into the catalog number 005 = 0. 1492-RTB10N (screw style terminals) or 1492-RTB10P (push-in style terminals). and 5. Use 1492-IFM20D120-2 for outputs. and 050 = 5. ➎ The voltage rating is relay control/coil voltage.January 2009 scIC8I➌ OBP16 OB16E OVP16 OW16 ITV16 OA16 OB16 OG16 OV16 IV16 OX8 . ORDER PLUGS SEPARATELY. Use a 1492-IFM20D120N or 1492-IFM20D120A-2 for inputs.5 mA. extender cable is provided. refer to page 192. ORDER PLUGS SEPARATELY.com.0 m). 025 = 2. ➍ This IFM is not recommended for use with PLC I/O modules that have an off-state leakage current exceeding 0. expander with 24V DC blown fuse indicators 1492-XIMF-F24-2 — — — — — — — — — — — — — ➊ ➊ ➊ — — — — — — — — — — — — — — — — — — — ➊ — — — — — — — — — — — — 1492-XIM2024-8R➒ 1492-XIM20120-8R➓ 1492-XIM2024-16R 1492-XIM2024-16RF — — — — — — — — — — — — — — — E E E — — — — — — — — — — — — — — — — — — — CR — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — E E E E E E — — — — — — — — — — — — — — — — — — 1492-XIM20120-16R 1492-XIM20120-16RF — — — — — — — — — — — — CR — — — — — — — — — — — — — — — — — — — — — — CR — — — — — — — — — — — — Relay Expander (LED Indicating) ➎➏ 1492-XIM24-8R 1492-XIM120-8R 1492-RXIM24-8R✱ — — — — — — — — — — — — ➊ ➊ ➊ — — — — — — — — — — — — — — — — — — — ➊ — — — — — — — — — — — — 8-ch.0 m. 1492-RTB12N (screw style terminals) or 1492-RTB12P (push-in style terminals). ➒ Expandable to 16 using XIM24-8R or XIMF-24-2.5 m (010 = 1.0 m. ➓ Expandable to 16 using XIM120-8R or XIMF-24-2. for Wiring System Module with Fixed Terminal Block Cat. expander with 120V AC 1492-XIMF-F120-2 blown fuse indicators Feed-through Expander Expander with eight feedthrough channels 1492-XIMF-2 — — — — — — — — — — — ➊ ➊ ➊ ➊ — — — — — — — — ➊ Can have up to 1 expandable module depending upon master used (total 16 pts or less). LED Indicating H H H H — H H H H H — H H H — H H — Standard with 24V AC/DC LEDs 24V AC/DC LEDs and extra terminals for outputs 24V AC/DC LEDs and extra terminals for inputs Note: Footnotes are on the following page. No.0 m cable. No. ✱ Compatible Removable Terminal Block (RTB) plug.5 m. contact Spectrum Controls (Phone: 425-641-9473) or at www. 2.5 m 1. ➋ Cables are available in standard lengths of 0. for Wiring System Module with System Module with Fixed Terminal Block Removable Terminal Block Socket Assembly (order plugs separately 1492-IFM40F 1492-IFM40F-2 1492-IFM40F-3 1492-IFM40D24 1492-IFM40D24-2 1492-IFM40D24A-2 1492-RIFM40F➏ 1492-RIFM40F-2➏ — 1490-RIFM40D24➏ — 1492-RIFM40D24A-2➏ I/O Module Catalog Number 1746-… OB32E H H — H H — OB32 OV32 H H — H H — IB32 IV32 Feed-through Standard 132V AC/DC Max.spectrumcontrols. and insert the letter in the box.5 m. ➌ For information concerning this I/O module. Bulletin 1746 SLC 500 IFMs and Cables. ORDER PLUGS SEPARATELY.0 m. 1492-RTB20N (screw style terminals) or 1492-RTB20P (push-in style terminals). Continued Bulletin 1746 Digital 32-Point I/O Modules ➋ Description of 40-PIN IFM Cat.Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems 31 Bulletin 1746 Digital 16-Point and 8-Point Isolated I/O Modules (Continued)➋ scOAP81➌ A Description of 20-PIN IFM Cat. For relay contact ratings. No. To order. 32 Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems Bulletin 1746 Digital 32-Point I/O Modules (Continued)➋ Description of 40-PIN IFM Cat. No. for Wiring Cat. No. for Wiring System Module with System Module with Fixed Terminal Block Removable Terminal Block Socket Assembly (order plugs separately 1492-IFM40D120-2 1492-IFM40D120A-2 1492-IFM40D24-3 1492-IFM40DS24-4 1492-IFM40DS24A-4 1492-IFM40DS120-4 1492-IFM40DS120A-4 1492-IFM40DS240A-4 1492-IFM40F-F-2 1492-IFM40F-F24-2 1492-IFM40F-F120-2 1492-IFM40F-FS-2 1492-IFM40F-FS24-2 1492-IFM40F-FS24-4 1492-IFM40F-FS-4 1492-IFM40F-FS120-2 1492-IFM40F-FS120-4 1492-IFM40F-FS240-4 1492-IFM40F-FS24A-4 1492-IFM40F-FSA-4 1492-IFM40F-FS120A-4 1492-IFM40F-FS240A-4 1492-XIM4024-8R 1492-XIM4024-16R 1492-XIM4024-16RF — — — — — — — — — 1492-RIFM40F-F24-2➏ — — — — — 1492-RIFM40F-FS120-2➏ 1492-RIFM40F-FS120-4❼ — — — 1492-RIFM40F-FS120A-4❼ — — — 1492-RXIM4024-16R➑ — — 1492-RXIM24-8R➒ — — — — — — — I/O Module Catalog Number 1746-… OB32E — — — — — — — — H H — — — — — — — — — — — — H H H ➊ ➌ — ➊ — ➊ OB32 OV32 — — — — — — — — H H — — — — — — — — — — — — — — — — — — — — — IB32 — — H — — — — — — — — — — — — — — — — — — — — — — IV32 — — H — — — — — — — — — — — — — — — — — — — — — — — — — — — — 120V AC LEDs and extra terminals for outputs 120V AC LEDs and extra terminals for inputs 3-wire sensor with 24V AC/DC LEDs 16 Individually isolated with 24/48V AC/DC LEDs and four terminals/output 16 Individually isolated with 24V AC/DC LEDs and four terminals/input 16 Individually isolated with 120V AC LEDs and four terminals/output 16 Individually isolated with 120V AC LEDs and four terminals/input 16 Individually isolated with 240V AC LEDs and four terminals/input Fusible — — — — — — — — H H — — — — — — — — — — — — H H H ➊ ➌ — ➊ — ➊ 120V AC/DC with extra terminals for outputs Extra terminals with 24V AC/DC blown fuse LED indicators for outputs Extra terminals with 120V AC/DC blown fuse LED indicators for outputs 16 Individually isolated with extra terminals for 120V AC/DC outputs 16 Individually isolated with extra terminals and 24V AC/DC blown fuse indicators 16 Individually isolated with 24V AC/DC blown fuse indicators and four terminals/output 16 Individually isolated 240V AC/DC with 4 terminals/output 16 Individually isolated with extra terminals and 120V AC/DC blown fuse LED indicators 16 Individually isolated with 120V AC/DC blown fuse LED indicators and four terminals/output 16 Individually isolated with 240V AC/DC blown fuse LED indicators and four terminals/output 16 Individually isolated with 24V AC/DC blown fuse LED indicators and four terminals/input 16 Individually isolated 120V AC/DC with 4 terminals/input 16 Individually isolated with 120V AC/DC blown fuse LED indicators and four terminals/input 16 Individually isolated with 240V AC/DC blown fuse LED indicators and 4 terminals/input Relay Master ➍➎ 40-pin master with eight (8) 24V DC relays 40-pin master with sixteen (16) 24V DC relays 40-pin master with sixteen (16) 24V DC relays with fusing Relay Expander (LED Indicating) ➍➎ Expander with eight (8) 24V DC relays Expander with sixteen (16) 24V DC relays with fusing Expander with eight (8) 120V AC relays Fusible Expander (LED Indicating) 8-channel expander with 24V DC blown fuse indicators 8-channel expander with 120V AC blown fuse indicators Feed through Expander Expander with eight feed-through channels 1492-XIM24-8R 1492-XIM24-16RF 1492-XIM120-8R 1492-XIMF-F24-2 1492-XIMF-F120-2 1492-XIMF-2 — — — — — — Note: Footnotes are on the following page. Publication 1492-TD008D-EN-P - January 2009 Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems 33 ➊ Can have up to two or three expandable modules depending upon master used (total 32 pts or less), extender cable is provided. ➋ Cables are available in standard lengths of 0.5 m 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the catalog number 005 = 0.5 m (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m), and insert the letter in the box. Example: Catalog Number 1492-CABLE050Yis for a 5.0 m cable, and the letter Y. ➌ 1492-XIM24-16RF is to be used with 1492-XIM4024-16R and 1492-XIM4024-16RF 32 PT. Only. ➍ The voltage rating is relay control/coil voltage. For relay contact ratings, refer to page 192. ➎ The LED indicates the PLC output status. ➏ Compatible Removable Terminal Block (RTB) plug; 1492-RTB20N (screw style terminals) or 1492-RTB20P (push-in style terminals). ORDER PLUGS SEPARATELY. ❼ Compatible Removable Terminal Block (RTB) plug; 1492-RTB17N (screw style terminals) or 1492-RTB17P (push-in style terminals). ORDER PLUGS SEPARATELY. ➑ Compatible Removable Terminal Block (RTB) plug; 1492-RTB14N (screw style terminals) or 1492-RTB14P (push-in style terminals). ORDER PLUGS SEPARATELY. ➒ Compatible Removable Terminal Block (RTB) plug; 1492-RTB12N (screw style terminals) or 1492-RTB12P (push-in style terminals). ORDER PLUGS SEPARATELY. Publication 1492-TD008D-EN-P - January 2009 34 Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems Selection Tables, Continued Bulletin 1746 SLC 500 IFMs and Cables, Continued These pre-wired cables have a pre-wired removable terminal block (RTB) on one end to connect to the front of a Bulletin 1746 digital I/O module and a connector on the other end to plug into a 20- or 40-terminal IFM/XIM. You must first select the IFM/XIM from one of the preceding selection tables. Pre-Wired Cables for Bulletin 1746 Digital I/O Modules Cable Cat. No. 1492-CABLE➊A 1492-CABLE➊B 1492-CABLE➊C 1492-CABLE➊CR 1492-CABLE➊D 1492-CABLE➊E 1492-CABLE➊G 1492-CABLE➊H 1492-CABLE➊N 1492-CABLE➊S Standard Cable Lengths 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m Build-to-Order Available Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No. of Conductors 20 20 20 20 20 20 20 40 20 20 Mating 1746 I/O Module Catalog Number 1746-IA16, -IM16 1746-IB16, -IH16, -IN16, -ITB16, -ITV16 1746-OA16 1746-OA16 1746-OW16, -OX8 1746-IG16, -OB16, -OB16E, -OBP16, -OG16, -OV16, -OVP16 1746-OA16 1746-IB32, -IV32, -OB32, -OB32E, -OV32 1746-OW16, -OX8 1746-OX8 ➊ Cables are available in standard lengths of 0.5 m, 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the catalog number (005 = 0.5 m, 010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Catalog Number 1492-CABLE005N is for a 0.5 m cable that could be used to connect a Catalog Number 1492-IFM20D24N IFM to a Catalog Number 1746-OW16 I/O module. Build-to-order lengths are also available. The I/O module-ready cables have a pre-wired RTB on one end to plug onto the front of a Bulletin 1746 I/O module and 20 or 40 individually colored #18 AWG conductors on the other end. These cables provide the convenience of pre-wired connections at the I/O module end, while still allowing the flexibility to field-wire to standard terminal blocks of your choice. I/O Module-Ready Cables for Bulletin 1746 Digital I/O Modules ➌ Cable Cat. No. 1492-CABLE➋N3 1492-CABLE➋RTBB 1492-CABLE➋RTBO 1492-CABLE➋RTBR Standard Cable Lengths 1.0, 2.5, 5.0 m 1.0, 2.5, 5.0 m 1.0, 2.5, 5.0 m 1.0, 2.5, 5.0 m Build-to-Order Available Yes Yes Yes Yes No. of Conductors 40 20 20 20 Mating 1746 I/O Module Catalog Number 1746-IB32, -IV32, -OB32, -OV32, -OB32E 1746-IB16, -IC16, -IG16, -IH16, -IN16, -ITB16, -ITV16, -IV16, -OB16, -OB16E, -OBP8, -OBP16, -OG16, -OV16, -OVP16 1746-OW16, -OX8 1746-IA16, -OA16, -OAP12, -IM16 ➋ Cables are available in standard lengths of 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the catalog number (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Catalog Number 1492-CABLE050RTBR is for a 5.0 m cable with a pre-wired Catalog Number 1746-RT25R RTB on one end. ➌ Digital I/O module-ready cables should not be used with analog module as a cable shield and drain wire is not provided. Note: The following I/O Modules do not have RTBs: 1746-IA4, 1746-IA8, 1746-IB8, 1746-IM4, 1746-IM8, 1746-IV8, 1746-OA8, 1746-OB8. Publication 1492-TD008D-EN-P - January 2009 0.5. 1.0. 5.0 0.0 m).5. Build-to-Order Available Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes AIFM Connector 15-pin D-shell 15-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 15-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell Mating 1746 I/O Module Catalog Number 1746-NI4 1746-NO4I. 1. 2. No.0.January 2009 NI16V NI16I . 5 terminals/input 8-channel input with 24V DC blown fuse indicators.5. insert the code for the desired cable length into the catalog number (005 = 0. 2.5.0. To use this table. 5.0. -FIO4V 1746-HSCE2 1746-QS 1746-N08I. ORDER PLUGS SEPARATELY. -FIO4I. 1. 5.5 m.5 m. insert the code for the desired cable length into the catalog number 005 = 0. Example: Catalog Number 1492-ACABLE005A is for a 0. 2. and 5. 1. and 050 = 5. -NO4V 1746-NI8 1746-NR4 1746-HSCE 1746-NIO4I.0 To order. 1. 025 = 2.0 m.5.0 m).5. 5.0. output or 2-in/2-out combination with 3 terminals/channel 6-channel isolated with 3…4 terminals/channel 8. for Wiring System Module with Fixed Terminal Block I/O Module Catalog Number 1746-… Cat. 2. 2.5 m. test points.5 m 1. These pre-wired cables have a pre-wired RTB on one end to connect to the front of a Bulletin 1746 analog I/O module and a connector on the other end to plug into a 15. -NIO4V.0.0.0 0.0 0.) HSCE2 (Diff. 2. -NI16V Pre-Wired Cables for Bulletin 1746 Analog I/O Modules Cable Catalog Number 1492-ACABLE➊A 1492-ACABLE➊B 1492-ACABLE➊C 1492-ACABLE➊D 1492-ACABLE➊K 1492-ACABLE➊L 1492-ACABLE➊P 1492-ACABLE➊Q 1492-ACABLE➊R 1492-ACAB➊A46 ➊ Standard Cable Lengths (m) 0. 2. ➎ Compatible Removable Terminal Block (RTB) plug. test points. 5.5 m cable. 5 terminals/input. 5.5.0.0 m.0 m. 010 = 1. ➍ Compatible Removable Terminal Block (RTB) plug.0 0. 1492-RTB8N (screw style terminals) or 1492-RTB8P (push-in style terminals). for Wiring System Module with Removable Terminal Block Socket Assembly (order plugs separately Feed-through 4-channel input.0 0. 2-channel output with 24V DC 1492-AIFM4C-F-5 blown fuse indicators. ➋ Cannot be used with SLC I/O. To order. 2.Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems 35 Selection Tables.0 0. 025 = 2. ➌ Compatible Removable Terminal Block (RTB) plug.5.5.5.5. N08V 1746-NI16I. and insert the letter in the box. 1.) FIO4I FIO4V NI4 NI8 NIO4I NIO4V NO4I NO8I NO4V NO8V NR4 QS — — L L A — L — — L L — — L Cat.5. 2. No.5. 5.5. you must first have selected an AIFM from the preceding table. Continued Bulletin 1746 Analog I/O Modules ➊ Description of AIFM Bulletin 1746 SLC 500 AIFMs and Cables HSCE (Diff.5 m.0 m. Example: Catalog Number 1492-ACABLE025A is for a 2. and 050 = 5. 1.or 16-channel input or output with 3 terminals/channel Thermocouple 6-channel with 3 terminals/channel➋ High-Speed Counter/Encoder 2-channel center input/2 outputs Fusible High Speed Counter/Encoder 2-channel fused counter input/4 fused outputs 1492-AIFMCE4-F Fusible Analog 2-channel input.5 m cable that could be used to connect a Catalog Number 1492-AIFM4I-F-5 IFM to a Catalog Number 1746-NI4 I/O module. 1. 5.or 25-pin D-shell terminal AIFM. 5 terminals/channel 16-channel input with 24V DC blown fuse indicators.0 0. 2. 2. 5 terminals/channel 1492-AIFM4I-F-5 1492-AIFM8-F-5 1492-AIFM16-F-3 1492-AIFM16-F-5 — L — — — — — — — — — K P — — — — — — — — — — — — — — 1492-AIFMCE4 — K P — — — — — — — — — — — — — — 1492-AIFM6TC-3 — — — — — — — — — — — — — — — — — 1492-AIFM4-3 1492-AIFM6S-3 1492-AIFM8-3 1492-RAIFM4-3➌ 1492-RAIFM6S-3➍ 1492-RAIFM8-3➎ L B — B — — — — — — — — — — — — — — — — — D — — — — — — — — C — — — R — R — — A46 A46 — — — — — — — — — A — — — — — — — — — — — — — — — — C — — — — — — — — — — — — — — — — — — — — — — — — A46 A46 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — Q — — 4-input/4-output channel with 8 fuses and 24V 1492-AIFMQS DC blown fuse indicators ➊ Cables are available in standard lengths of 0. Publication 1492-TD008D-EN-P .5.5 m (010 = 1. 5. 3 terminals/channel 16-channel input with 24V DC blown fuse indicators.5.0 0. ORDER PLUGS SEPARATELY. and the letter A.5. 1492-RTB16N (screw style terminals) or 1492-RTB16P (push-in style terminals). 1. ORDER PLUGS SEPARATELY. 1. 3 terminals/output 4-channel input with 24V DC blown fuse indicators.5.0.0 0. 5.5. 1492-RTB12N (screw style terminals) or 1492-RTB12P (push-in style terminals).5. for Wiring System Module with Fixed Terminal Block Cat. If there is no letter code. the 1492 Wiring System Module is not compatible with the I/O module. Find the appropriate table based on the catalog number of the 1756 I/O module. 3. Configure the cable catalog number using 1492-CABLE➊ (for digital cables) or 1492-ACABLE➊ (for analog cables). Find the column in the selected table for the 1756 I/O module. NOTE: The letter codes designate the compatible 1492 cable for that 1756 I/O and 1492 Wiring System Module combination. Bulletin 1756 ControlLogix IFMs and Cables Bulletin 1756 Digital 8-Point and 16-Point I/O Modules ➋ Description of 20-PIN IFM OB16E OV16E X X X X X — X X OA8D Cat.36 Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems Selection Tables. Publication 1492-TD008D-EN-P . See footnote ➊ on pages 40 and 42.: 1. No. Narrow standard 132V AC/DC Max. 4. LED Indicating Standard with 24V AC/DC LEDs Narrow standard with 24V AC/DC LEDs Standard with 120V AC/DC LEDs Narrow standard with 120V AC LEDs 24V AC/DC LEDs and extra terminals for outputs 24V AC/DC LEDs and extra terminals for inputs 120V AC LEDs and extra terminals for outputs 120V AC LEDs and extra terminals for inputs 3-wire sensor with 24V AC/DC LEDs 8 Individually isolated with 24/48V AC/DC LEDs and 4 terminals/output 8 Individually isolated with 120V AC LEDs and 4 terminals/output 240V AC LEDs with extra terminals for outputs 240V AC LEDs with extra terminals for inputs Fusible 120V AC/DC with extra terminals for outputs Extra terminals with 24V AC/DC blown fuse LED indicators Extra terminals with 120V AC/DC blown fuse LED indicators 1492-IFM20F-F-2 1492-IFM20F-F24-2 1492-IFM20F-F120-2 1492-RIFM20F-F-2➏ 1492-RIFM20F-F24-2➏ 1492-RIFM20F-F120-2➏ — — — — — — — — — X — — X X — — — — — — — — — — — — — — — — — — — — — — — X 1492-IFM20D24 1492-IFM20D24N 1492-IFM20D120 ➌ 1492-IFM20D120N 1492-IFM20D24-2 1492-IFM20D24A-2 1492-IFM20D120-2 1492-IFM20D120A-2 1492-IFM20D24-3 1492-IFM20DS24-4 1492-IFM20DS120-4 1492-IFM20D240-2 1492-IFM20D240A-2 — — — — — — — — — — — — — — — — — U U X X X X — — X X X X — — — — — — — — X — — X X — — — — — 1492-IFM20F 1492-IFM20FN 1492-IFM20F-2 1492-IFM20F-3 1492-RIFM20F➏ 1492-RIFM20FN➐ 1492-RIFM20F-2➏ — U U U — X X X X X X X X X X X X X X X X X X X X U U U U U U U U U X X X U U U X X X — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — X — — — — — — — — — — — — — — X — X X — — — — X — — — — — — — — — — — — — — — — — — — — W — W — — — — — — — — — U X — — — — — — — — X — X X — — — — — — — — — — — — — — — — — — — — — — W V V — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — Note: Footnotes are on the following page. 2.January 2009 . No. Continued Using Bulletin 1756 Selection Tables to Make Valid 1492 Wiring System Module Catalog Numbers Follow these steps when using the selection tables to make valid catalog numbers. Follow the column down to determine which Wiring System Modules are compatible with the I/O module as indicated by letter code. Select the desired 1492 Wiring System Module. 5. 3-wire sensor type input devices 132V AC/DC Max. Extra terminals (2 per I/O) 264V AC/DC Max. for Wiring System Module with Removable Terminal Block Socket Assembly (order plugs separately I/O Module Catalog Number 1756-… OA8E OA16 IA8D IN16 IA16 IB16 ON8 U U U W IC16 IV16 OA8 OB8 OC8 U U U Feed-through Standard 264V AC/DC Max. For relay contact ratings. ➐ Compatible Removable Terminal Block (RTB) plug.0 m). 1492-RTB12N (screw style terminals) or 1492-RTB12P (push-in style terminals). for Wiring System Module with Fixed Terminal Block Cat.5 m.0 m. refer to page 192. and insert the letter in the box. ➍ The voltage rating is relay control/coil voltage. and 050 = 5. insert the code for the desired cable length into the catalog number 005 = 0.0 m. To order. 025 = 2. ➏ Compatible Removable Terminal Block (RTB) plug 1492-RTB20N (screw style terminals) or 1492-RTB20P (push-in style terminals). ORDER PLUGS SEPARATELY. for Wiring System Module with Removable Terminal Block Socket Assembly (order plugs separately — 1492-RIFM20F-F24A-2➏ 1492-RIFM20F-F120A-2➏ — — I/O Module Catalog Number 1756-… OA8E OA16 IA8D IN16 IA16 IB16 IC16 IV16 ON8 W W OA8 OB8 OC8 Extra terminals with 240V AC/DC blown fuse LED indicators Extra terminals with 24V AC/DC blown fuse LED indicators Extra terminals with 120V AC/DC blown fuse LED indicators 8 Individually isolated 120V AC/DC with extra terminals for outputs 8 Individually isolated with extra terminals/output and 24V AC/DC blown fuse LED indicators Two 4-point isolated groups with four terminals/input and 24V AC/DC blown fuse LED indicators 8 Individually isolated with extra terminals output. and 120V AC/DC blown fuse LED indicators 8 Individually isolated with 4 terminals/output and 120V AC/DC blown fuse LED indicators Two 4-point isolated groups with four terminals/input and 120V AC/DC blown fuse indicators 8 Individually isolated with 4 terminals/output and 240V AC/DC blown fuse LED indicators Relay Master (LED Indicating) ➍➎ 20-pin master with eight (8) 24V DC relays 20-pin master with eight (8) 120V AC relays 20-pin master with sixteen (16) 24V CD relays 20-pin master with sixteen (16) 24V DC relays with fusing 20-pin master with sixteen (16) 120V AC relays 20-pin master with sixteen (16) 120V AC relays with fusing Relay Expander (LED Indicating) ➍➎ Expander with eight (8) 24V DC relays Expander with eight (8) 120V AC Relays Fusible Expander Expander with eight (8) 24V channels with blown fuse indicators Expander with eight (8) 120V channels with blown fuse indicators Feed-through Expander Expander with eight (8) feed-through channels 1492-IFM20F-F240-2 1492-IFM20F-F24A-2 1492-IFM20F-F120A-2 1492-IFM20F-FS-2 1492-IFM20F-FS24-2 — — — — — — — — — — — — X X — X X — — — — — — — — — — — — — — — W W — W — W — — — — — — — — — — — — — V V — — — — — — — W — — — — — — — — — — 1492-IFM20F-FS24A-4 — — — — — — — — — — — — — — — — 1492-IFM20F-FS120-2 — — — — — — — W V V — — — — — — 1492-IFM20F-FS120-4 — — — — — — — W V V — — — — — — 1492-IFM20F-FS120A-4 — U — — — — — — — — — — — — — — 1492-IFM20F-FS240-4 — — — — — — — W — — — — — — — — 1492-XIM2024-8R➑ 1492-XIM20120-8R➒ 1492-XIM2024-16R 1492-XIM2024-16RF 1492-XIM20120-16R 1492-XIM20120-16RF — — — — — — — — — — — — — — — — — — — — — — — — — X — X — — — — — — — — — — X X — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — X X — — — — — — — — — — 1492-XIM24-8R 1492-XIM120-8R 1492-XIMF-F24-2 1492-XIMF-F120-2 1492-RXIM24-8R✱ — — — — — — — — — — — — — — — — — — — — — — ➊ — ➊ — — — — — — — — — ➊ — — — — — — — — — — — — — — — — — — — — — — ➊ — — — — — 1492-XIMF-2 — — — — — — — — — — ➊ — ➊ — — — ➊ Can have up to 1 expandable module depending upon master used (total 16 pts or less) extender cable is provided.5 m 1.0 m cable. 2. Use a 1492-IFM20D120N or 1492-IFM20D120A-2 for inputs. Publication 1492-TD008D-EN-P . ORDER PLUGS SEPARATELY. and 5. No.5 mA. Use 1492-IFM20D120-2 for outputs. ➌ This IFM is not recommended for use with PLC I/O modules that have an off-state leakage current exceeding 0.January 2009 .Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems 37 Bulletin 1756 Digital 8-Point and 16-Point I/O Modules (Continued)➋ Description of 20-PIN IFM OB16E OV16E — — OA8D Cat. ORDER PLUGS SEPARATELY. ➋ Cables are available in standard lengths of 0. Example: Catalog Number 1492-CABLE050W is for a 5.5 m (010 = 1.5 m. ➒ Expandable to 16 using XIM120-8R or XIMF-24-2. 1492-RTB10N (screw style terminals) or 1492-RTB10P (push-in style terminals). ➑ Expandable to 16 using XIM24-8R or XIMF-24-2. ➎ The LED indicates the PLC output status. No. ✱ Compatible Removable Terminal Block (RTB) plug.0 m. and the letter W. 4 isolated groups.05 mA) LED circuit. 4 isolated groups. Extra terminals (2 per I/O) 132V AC/DC Max. Continued Bulletin 1756 Digital 16-Point Isolated and 32-Point I/O Modules ➋ Cat.38 Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems Selection Tables. Continued Description of 40-PIN IFM Bulletin 1756 ControlLogix IFMs and Cables. 2 terminals/output Individually Fused w/24V DC blown fuse low leakage (0. for Wiring Cat. for Wiring System Module with System Module with Fixed Terminal Block Removable Terminal Block Socket Assembly (order plugs separately 1492-IFM40F 1492-IFM40F-2 1492-IFM40F-3 1492-IFM40D24 1492-IFM40D24-2 1492-IFM40D24A-2 1492-IFM40D120-2 1492-IFM40D120A-2 1492-IFM40D24-3 1492-IFM40DS24-4 1492-IFM40DS24A-4 1492-IFM40DS120-4 1492-IFM40DS120A-4 1492-IFM40DS240A-4 1492-IFM40F-F-2 1492-IFM40F-F24-2 1492-IFM40F-F24D-2 1492-RIFM40F➑ 1492-RIFM40F-2➑ — 1492-RIFM40D24➑ — 1492-RIFM40D24A-2➑ — — — — — — — — — 1492-RIFM40F-F24-2➑ — I/O Module Catalog Number 1756-… OB16IS OB16D OW16I OV32E OB8EI OB16I IB16D OA16I IM16I OB32 IA16I IB16I IH16I OH8I OX8I Y Y Y Y Y Y Y IA32 IB32 Z Z IV32 Feed-through Standard 132V AC/DC Max. No. LED Indicating Standard with 24V AC/DC LEDs 24V AC/DC LEDs and extra terminals for outputs 24V AC/DC LEDs and extra terminals for inputs 120V AC LEDs and extra terminals for outputs 120V AC LEDs and extra terminals for inputs 3-wire sensor with 24V AC/DC LEDs 16 Individually isolated with 24/48V AC/DC LEDs and 4 terminals/output 16 Individually isolated with 24V AC/DC LEDs and 4 terminals/input 16 Individually isolated with 120V AC LEDs and 4 terminals/output 16 Individually isolated with 120V AC LEDs and 4 terminals/input 16 Individually isolated with 240V AC LEDs and 4 terminals/input Fusible 120V AC/DC with extra terminals for outputs Extra terminals with 24V AC/DC blown fuse indicators for outputs 16 Individually fused with 24V DC blown fuse low leakage (0. 4 terminals/input Extra terminals with 120V AC/DC blown fuse indicators for outputs 16 Individually isolated with extra terminals for 120V AC/DC outputs 16 Individually isolated with extra terminals and 24V AC/DC blown fuse indicators for outputs 16 Individually isolated with 24V AC/DC blown fuse indicators and 4 terminals/output 16 Individually isolated 240V AC/DC with 4 terminals/output 16 Individually isolated with extra terminals and 120V AC/DC blown fuse LED indicators 16 Individually isolated with 120V AC/DC blown fuse indicators and 4 terminals/output Y Y Y Z — Y — Z Z Y — Y Y Y Y Y Z Z — — — — Y — — Z Z Y Y Y Z — — — — — — — Z Z — — — — — — — — — — — — Z — — — Z — — — — — — — Z Z — — — — — — — Z — — — — — — — — — — — — — Z — — — — Z Z — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — Z — — — — — — — — — — — — — — — — — — Z Z — — — — — — — — — — — — — — — — — — — — — Y Y Y Y — — — Y Y ♣ — Y Y — — — — — — — — — — — — — — — — — — — — — — — Y — — — — — — — Y Y — — — — — — — — — — — — — — — — — — — — — — — — Y — — — — — — — — — — — — — — — — — — — — — — — Z — — — — — — — — — — — — — Z Z — — — Z — — — — — — — — — — — — — Y — — — — — — — 1492-IFM40F-F24AD-4 — — Y — — — — — — — — — — — — — — — — 1492-IFM40F-F120-2 1492-IFM40F-FS-2 1492-IFM40F-FS24-2 1492-IFM40F-FS24-4 1492-IFM40F-FS-4 1492-IFM40F-FS120-2 1492-IFM40F-FS120-4 — — — — — 1492-RIFM40F-FS120-2➑ 1492-RIFM40F-FS120-4➒ — — — — — — — — — — — — — — — — — — — — — — — — — — Y Y ➤ — — — — — — — — — Y ➐ Y ➤ Y Y Y — — Y Y ➤ Y — — — Y ➤ — — — — — — — — — Y ➐ Y Y — — — Y ➤ ➤ — — — — — — — — Y Y Y — — — Y ➤ ➤ — — — — — — — — Y — — — — — — Y Y — — — — — — — — Y — — — — — — — Y Y Y Publication 1492-TD008D-EN-P . No. 3-wire sensor type input devices 60V AC/DC Max.January 2009 .05 mA) LED circuit. 5 m. and 050 = 5. use the 1492-IFM40F-2.0 m. ➋ Cables are available in standard lengths of 0. and 5. Due to the magnitude of current through the LED.5 m (010 = 1. Only). 1492-RTB14N (screw style terminals) or 1492-RTB14P (push-in style terminals). and the letter Y. refer to page 192.January 2009 . ORDER PLUGS SEPARATELY. the “wire off” diagnostic function of the 1756-IB16D will not indicate a blown or removed fuse as a wire off condition. ORDER PLUGS SEPARATELY. for Wiring Cat. 1492-RTB20N (screw style terminals) or 1492-RTB20P (push-in style terminals). you must use a 1492-IFM40F-F24D-2. insert the code for the desired cable length into the catalog number 005 = 0. If this function is required. ➍ The voltage rating is relay control/coil voltage. and insert the letter in the box. If you require this diagnostic to function for a blown or removed fuse. ➐ The 1492-IFM40F-FS24-2 and 1492-IFM40F-FS24-4 module and 1492-CABLE➋Y cable can be used with the 1756-OB16D module. ORDER PLUGS SEPARATELY. ➌ One 1492-XIM24-16RF is to be used with one 1492-XIM4024-16R or 1492-XIM4024-16RF master (32 PT. ➒ Compatible Removable Terminal Block (RTB) plug. Example: Catalog Number 1492-CABLE050Y is for a 5.5 m 1. However. due to the 1492-IFM40F-FS24A-4 module’s blown fuse leakage current rating. 025 = 2. ➓ Compatible Removable Terminal Block (RTB) plug. ➏ The 1492-IFM40F-FS24A-4 module and 1492-CABLE➋Y cable can be used with the 1756-IB16D module. 1492-RTB17N (screw style terminals) or 1492-RTB17P (push-in style terminals). However. the “no load” diagnostic function of the 1756-OB16D will not indicate a blown or removed fuse as a no load condition. If you require this diagnostic to function for a blown or removed fuse.5 m. No. ➎ The LED indicates the PLC output status. Publication 1492-TD008D-EN-P .Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems 39 Bulletin 1756 Digital 16-Point Isolated and 32-Point I/O Modules (Continued)➋ Description of 40-PIN IFM Cat. No. ♣ IFMs LED provides PLC output ON/OFF indication. ORDER PLUGS SEPARATELY. due to the 1492-IFM40F-FS242 and 1492-IFM40F-FS24-4 module’s blown fuse leakage current rating. To order. ✪ Compatible Removable Terminal Block (RTB) plug. ➤ Do not use this module in output sinking mode with fused IFM modules as the IFM module fuses will not properly protect the circuit.0 m cable. 1492-RTB12N (screw style terminals) or 1492-RTB12P (push-in style terminals). For relay contact ratings.0 m. for Wiring System Module with System Module with Fixed Terminal Block Removable Terminal Block Socket Assembly (order plugs separately 1492-IFM40F-FS240-4 — — — 1492-RIFM40F-FS120A-4➒ — I/O Module Catalog Number 1756-… OB16IS OB16D OW16I OV32E OB8EI OA16I OB16I IB16D IM16I OB32 IA16I IB16I IH16I OH8I OX8I Y IA32 IB32 IV32 16 Individually isolated with 240V AC/DC blown fuse indicators and 4 terminals/output 16 Individually isolated with 24V 1492-IFM40F-FS24A-4 AC/DC blown fuse indicators and 4 terminals/input 16 Individually isolated 120V AC/DC 1492-IFM40F-FSA-4 with 4 terminals/input 16 Individually Isolated with 120V 1492-IFM40F-FS120A-4 AC/DC blown fuse indicators and 4 terminals/input 16 Individually isolated with 240V 1492-IFM40F-FS240A-4 AC/DC blown fuse indicators and 4 terminals/input Relay Master (LED Indicating) ➍➎ 40-pin master with eight (8) 24V DC 1492-XIM4024-8R relays 40-pin master with sixteen (16) 24V 1492-XIM4024-16R DC relays 40-pin master with sixteen (16) 24V 1492-XIM4024-16RF DC relays with fusing Relay Expander (LED Indicating) ➍➎ 1492-XIM24-8R Expander with eight (8) 24V DC relays Expander with eight (8) 120V AC 1492-XIM120-8R relays Fusible Expander 1492-XIMF-F24-2 8-channel expander with 24V DC blown fuse indicators 8-channel expander with 120V AC 1492-XIMF-F120-2 blown fuse indicators Expander with sixteen (16) 24V DC 1492-XIM24-16RF relays with fusing Feed-through Expander 1492-XIMF-2 Expander with eight (8) feedthrough channels — — — — — — — — Y — — — — — — — Y — ➏ Y Y Y — — — — — — — — — — — — — — — Y — — — Y — — — — — — — — — — — Y — — — — — Y — — — — — — — — — — — — — — — — — — Y — — — — — — — — — — — 1492-RXIM4024-16R➓ — 1492-RXIM24-8R✪ — — — — — — — — — — — — — — — — — — Z — — — — — — — — — — — — — — — — — Z — — — — — — — — — — — — — — — — — Z — — — — — — — — — — — — — — — — — ➊ — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — ➊ — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — ➌ — — — — — — — — — — — — — — — — — ➊ — — — — ➊ Can have up to two or three expandable modules depending upon master used (total 32 pts or less). ➑ Compatible Removable Terminal Block (RTB) plug. extender cable is provided.0 m). 2. you must use a 1492-IFM40F-F24AD-4. the 1756-0B16D PLC module “No Load” diagnostic function will not work.0 m. -OA16I.0. and 5. 2. Continued Bulletin 1756 ControlLogix IFMs and Cables.0 m). -OC8. ➌ Discrete I/O ready cables should not be used with PLC analog I/O modules as cable shield and drain wires are not provided. -IV32.5 m. 5. -OA8E.5 m cable that could be used to connect a Catalog Number 1492-IFM40F IFM to a Catalog Number 1756-IA16I I/O module. -IH16. -IM16I. -IB16D. -IV16. and 050 = 5.0 m Build-to-Order Available Yes Yes Yes Yes Yes Yes No. of Mating 1756 Conductors I/O Module Catalog Number 20 20 20 20 40 40 1756-IA8D.0 m). 5. -OB32. Example: Catalog Number 1492-CABLE005Y is for a 0. -ON8 1756-OA8D.5. -OB16E. -OB8EI.0 m.0 m 0. 1492-CABLE➋TBNH 1492-CABLE➋TBCH Standard Cable Lengths 1. -IN16. -OV16E 1756-IA16I. -ON8 1756-IA16. -OA8. -OA16. -OB16I. -IB16I. 1. The I/O module-ready cables have a pre-wired RTB on one end to plug onto the front of a Bulletin 1756 I/O module and 20 or 40 individually colored #18 AWG conductors on the other end. -OC8. Pre-Wired Cables for Bulletin 1756 Digital I/O Modules Cable Cat.0 m Build-to-Order Available Yes Yes No.0 m. -OB8. -OC8. 010 = 1. 5. -IB16D. -OV32E. -OA8. 2.0 m. -IN16. -OB8.5. -IH16I. -IM16I. To order. -OA8D. I/O Module-Ready Cables for Bulletin 1756 Digital I/O Modules ➌ Cable Cat. 2. -OW16I. 2.0. insert the code for the desired cable length into the catalog number (010 = 1. 025 = 2.0. -OB16D.5. 1. 2. -OV16E 1756-IA16I. 1. while still allowing the flexibility to field-wire to standard terminal blocks of your choice. 5. -OB16IS. -OH8I. and 050 = 5. and 5. -OW16I.0. 1492-CABLE➊U 1492-CABLE➊V 1492-CABLE➊W 1492-CABLE➊X 1492-CABLE➊Y 1492-CABLE➊Z Standard Cable Lengths 0.0 m cable with a pre-wired Catalog Number 1756-TBNH RTB on one end.5.5 m. 5.5 m. 2.0. -OB16IS. -IA32.0. -OB32. -OA16. -IC16. To order.0.0 m 0. -OA8E. -OV32E ➊ Cables are available in standard lengths of 0. -IB16. Continued These pre-wired cables have a pre-wired RTB on one end to connect to the front of a Bulletin 1756 digital I/O module and a connector on the other end to plug into a 20. These cables provide the convenience of pre-wired connections at the I/O module end.5.0 m 1.5. 5. -OB8EI. -OH8I. -IA16. of Mating 1756 Conductors I/O Module Catalog Number 20 40 1756-IA8D. -OX8I 1756-IB32. -IB32.0 m.5 m. Example: Catalog Number 1492-CABLE050TBNH is for a 5. -IB16I.5 m. -IB16.or 40-terminal IFM/XIM. -ON8. 5. 1.5. -OA16I. 025 = 2. -OB16E.0.5.5.0 m 0.5 m. No. 2. -OX8I ➋ Cables are available in standard lengths of 1.5. Publication 1492-TD008D-EN-P . 2.0 m. insert the code for the desired cable length into the catalog number (005 = 0. 1. 2.0 m 0. -OA8E 1756-OA8.40 Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems Selection Tables.5. No. 1. -OB8. You must first select the IFM/XIM from one of the preceding selection tables. -IC16.0 m.January 2009 . -IV16.0 m 0. 5.5.5. -IV32. 1. -OB16I. -OB16D.5. 2. -OA8D. and the letters TB. insert the code for the desired cable length into the catalog number 005 = 0.5 m 1. Example: Catalog Number 1492-ACABLE025TB is for a 2. ORDER PLUGS SEPARATELY.5 m (010 = 1.January 2009 PIM — — — — — M IR6I IT6I Cat. ORDER PLUGS SEPARATELY. Publication 1492-TD008D-EN-P . ➍ Compatible Removable Terminal Block (RTB) plug.0 m. 5 terminals/channel 8 input/ 2 output channels 1492-AIFM8-F-5 — — — ZA ZB ZC — — — TA TB TC TD UC UD — — UC UD — — — — — — — — — — — 1492-AIFMCE4-F — XA XB — — — — — — — — — — — — — — — — — — — — — — — — — — — — XA XB — — — — — — — — — — — — — — — — — — — — — — — — — — — 1492-AIFM16-F-3 — — — — — — — — — — — — — — — UA UB UC UD — — — — — — — — — — 1492-AIFM16-F-5 — — — — — — — — — — — — — — — UA UB UC UD — — — — — — — — — — 1492-AIFMPI — — — — — — — — — — — — — — — — — — — — — — — — — — — — — ➊ Some analog I/O modules can be operated in up to four modes (current/voltage.) IF8H (Voltage) HCS (5V Diff. ➌ Compatible Removable Terminal Block (RTB) plug. single-ended/differential) based on connections. 2. and 5. 1492-RTB16N (screw style terminals) or 1492-RTB16P (push-in style terminals).Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems 41 Selection Tables. you can field configure any channel for another mode. 5 terminals/channel 16-channel input with 24V DC blown fuse indicators. output or 2in/2-out combination with 3 terminals/channel 6-channel isolated with 3…4 terminals/channel 8. No. ➎ Compatible Removable Terminal Block (RTB) plug.0 m).0 m. However. and insert the letter in the box.) OF4 (Voltage) OF8 (Voltage) IF6I (Voltage) OF4 (Current) OF8 (Current) IF6I (Current) IF6CIS OF6CI OF6VI IT6I2 Feed-through 4-channel input. You made need to alter the terminal block wiring to match the application. Continued Bulletin 1756 Analog I/O Module ➊ ➋ Description of AIFM Catalog Number for Wiring System Module with Fixed Terminal Block Catalog Number for Wiring System Module with Removable Terminal Block Socket Assembly (order plugs separately Bulletin 1756 ControlLogix AIFMs and Cables IF4FXOF2F (Cur In & Volt Out IF4FXOF2F (Volt In & Out IF4FXOF2F (Cur In & Out IF16 (Sgl-End Current) IF8 (Sgl-End Current) OF8H (Current/Hart) — — WB — — — — — — — IF8H (Current/Hart) IF16 (Sgl-End Volt) IF16 (Diff Voltage) IF16 (Diff Current) IF8 (Sgl-End Volt) IF8 (Diff Voltage) IF8 (Diff Current) OH8H (Voltage) HSC (24V Diff. 1757 I/O Module Catalog Number 1756 . 025 = 2. ORDER PLUGS SEPARATELY. To order. each channel is factoryconfigured for the same mode.0 m. 1492-RTB8N (screw style terminals) or 1492-RTB8P (push-in style terminals). 1492-RTB12N (screw style terminals) or 1492-RTB12P (push-in style terminals). and 050 = 5. In all cases. 3 terminals/channel 16-channel input with 24V DC blown fuse indicators.5 m. Refer to the PLC installation manual ➋ Cables are available in standard lengths of 0.5 m.5 m cable.or 16-channel input or output with 3 terminals/channel Thermocouple 6-channel with 3 terminals/channel 1492-AIFM4-3 1492-RAIFM4-3➌ — — — — — — — — — — — — — — — — — — — — — VA VB — — — — — — 1492-AIFM6S-3 1492-AIFM8-3 1492-RAIFM6S-3➍ — 1492-RAIFM8-3➎ — — ZA ZB ZC X Y Z — — — — — — — — UB — UC — Z — — — — — Y Y — WB — WA — — — — — — — TA TB TC TD UC UD UA UD — — — — — — WA 1492-AIFM6TC-3 — — — — — — — — — — — — — — — — — — — — Y YT — — — — — — — High Speed Counter/Encoder 1492-AIFMCE4 2-channel counter input/4 outputs Fusible High-Speed Counter/Encoder 2-channel fused counter input/4 fused outputs Fusible Analog 8-channel input with 24V DC blown fuse indicators. 5.0 m. 5.5. 2. -OF8H (Current/Hart) 1756-HSC (24V DC Diff.5. 1.5.0 m 0.0.0 m 0.5. and 5. 1.5.) 1756-HSC (5V DC Diff.0. 2.42 Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems Selection Tables.0 m 0. 2. -OF6CI.0.5.0 m 0.0.0 m 0. insert the code for the desired cable length into the catalog number (005 = 0. 1. Voltage 1756-IF8 Diff.0 m 0. 2. 5. 5.0. 5. -IF8H (Voltage) 1756-IF16 Diff.0 m 0. 5.0 m 0.5 m. 5.0.5.or 25-pin D-shell terminal AIFM. 2.5. 5.5. 2. 2.5. 2.5. Pre-Wired Cables for 1756 Analog I/O Modules Cable Catalog Number 1492-ACABLE➊M 1492-ACABLE➊X 1492-ACABLE➊Y 1492-ACABLE➊YT 1492-ACABLE➊Z 1492-ACABLE➊TA 1492-ACABLE➊TB 1492-ACABLE➊TC 1492-ACABLE➊TD 1492-ACABLE➊UA 1492-ACABLE➊UB 1492-ACABLE➊UC 1492-ACABLE➊UD 1492-ACABLE➊VA 1492-ACABLE➊VB 1492-ACABLE➊WA 1492-ACABLE➊WB 1492-ACABLE➊XA 1492-ACABLE➊XB 1492-ACABLE➊ZA 1492-ACABLE➊ZB 1492-ACABLE➊ZC Standard Cable Lengths 0.5.0. 1. 1.0 m 0. 1.5. IF8H (Current/Hart) 1756-OF4 Voltage 1756-OF4 Current 1756-OF8 Voltage.0 m 0. 1.5 m cable that could be used to connect a Catalog Number 1492-AIFM6TC-3 analog IFM to a Catalog Number 1756-IT6I I/O module. Voltage. 1. 5. 1.5 m. 2. 2.0 m). -IF6CIS 1756-IF8 Single-Ended Voltage 1756-IF8 Single-Ended Current 1756-IF8 Diff.0. You must first select the AIFM from the preceding selection table.5.5.5. 1.5. Example: Catalog Number 1492-ACABLE005Y is for a 0.5.0. 2.5.0 m 0. 5.0. 5. 2. 5.5.0 m Build-to-Order Available Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes AIFM Connector 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 15-pin D-shell 15-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell Mating 1756 I/O Module Catalog Number 1757-PIM 1756-IF16 Current 1756-IF16 Voltage.5. Current 1756-IF16 Single-Ended Voltage 1756-IF16 Single-Ended Current 1756-IF16 Diff. 1.0 m 0. To order.5. 1.5.0.) 1756-IF4FXOF2F (Cur In & Out) 1756-IF4FXOF2F (Volt In & Out) 1756-IF4FXOF2F (Cur In & Volt Out) ➊ Cables are available in standard lengths of 0.5. 2. -OF6VI 1756-IT6I2 1756-IR6I.0.5.5.5 m.5. 1. 5. 2. 5. 010 = 1.5 m. 5. 5.0 m 0.0 m 0.5.5.0 m 0. 5. 2.0 m. 2.0.5.5.5. Continued Bulletin 1756 ControlLogix AIFMs and Cables.5. 1. 1. Publication 1492-TD008D-EN-P .0.0 m 0.5. 2. 5. 5. Continued These pre-wired cables have a pre-wired RTB on one end to connect to the front of a Bulletin 1756 analog I/O module and a D-shell connector on the other end to plug into a 15. 1.0.5. 1.0. 5.5.0.5.0 m 0.0. 1. 1.January 2009 . 1.5.5. -OF8H (Voltage) 1756-OF8 Current.5.0 m 0. -IT6I.0. 5.0 m.5.0 m 0. 2. 1. 1.5.0. 2.0. 5.5. 2. 2.0. 5. and 050 = 5.0 m 0. Current. 025 = 2.0 m 0. 2. 1. 2. Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems 43 Selection Tables, Continued Using Bulletin 1762/1764 Selection Tables to Make Valid 1492 Wiring System Module Catalog Numbers Follow these steps when using the selection tables to make valid catalog numbers: 1. Find the appropriate table based on the catalog numbers of the 1762/1764 controller. 2. Find the column for the 1762/1764 I/O. 3. Follow the column down to determine which Wiring System Modules are compatible with the I/O as indicated by letter and number (e.g. A62) code. If there is no letter/number code, the Wiring System Module is not compatible with the I/O module. NOTE: The letter/number codes designate the compatible 1492 cable for that 1762/1764 I/O and Wiring System Module combination. 4. Select the desired Wiring System Module. 5. Configure the cable catalog number using 1492-CAB➊. See footnote ➊ on pages 43 and 44. MicroLogix 1200 Embedded 40 I/O Controllers to IFM Selection Tables Bulletin 1762-L40x Compatible 40-Terminal 1492-IFMs Description of 40-PIN IFM -L40BWA Outputs B62 B62 -L40AWA Outputs Cat. No. for Wiring System Module with Fixed Terminal Block Cat. No. for Wiring System Module with Removable Terminal Block Socket Assembly (order plugs separately 1762 Embedded I/O Controller -L40BXB Outputs B62 B62 -L40BWA Inputs A62 A62 -L40AWA Inputs -L40BXB Inputs A62 A62 Feed-through Standard 132V AC/DC Max. Extra terminals 132V AC/DC Max. ❶ ➋ 1492-IFM40F❶ 1492-IFM40F-2❶ 1492-RIFM40F❶➋ 1492-RIFM40F-2❶➋ A62 A62 B62 B62 When using this IFM module with the base I/O of the 1762 controller, the current rating of the ouputs must be considered. Compatible Removable Terminal Block (RTB) plug; 1492-RTB20N (screw style terminlas) or 1492-RTB20P (push-in style terminals). ORDER PLUGS SEPARATELY. These pre-wired cables have a pre-wired removable terminal block (RTB) on one end to connect to the front of the Bulletin 1762 controller embedded digital I/O and a connector on the other end to plug into a 40-terminal IFM. You must first select the IFM from the preceding selection table. Pre-Wired Cables for 1762-L40x Embedded I/O Controllers Cable Cat. No. 1492-CAB➊A62 1492-CAB➊B62 Standard Cable Lengths 0.5, 1.0, 2.5, 5.0 0.5, 1.0, 2.5, 5.0 Build-to-Order Available Yes Yes No. of Conductors 40 40 Mating 1762-L40x Embedded I/O Controller -L40AWA Inputs, -L40BWA Inputs, -L40BXB Inputs -L40AWA Outputs, -L40BWA Outputs, -L40BXB Outputs ➊ Pre-wired cables are available in standard lengths of 0.5 m, 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the catalog number (005 = 0.5 m, 010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Catalog Number 1492-CAB005A62 is for a 0.5 m cable that could be used to connect a Catalog Number 1492-IFM40F to a Cat. No. 1762-L40AWA Input. Publication 1492-TD008D-EN-P - January 2009 44 Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems Selection Tables, Continued The I/O module-ready cables have a pre-wired RTB on one end to plug onto the front of the Bulletin 1762 controller embedded I/O and 25 or 40 individually colored conductors on the other end. These cables provide the convenience of pre-wired connections at the controller embedded I/O end, while still allowing the flexibility to field-wire to standard terminal blocks of your choice. Build-to-Order Available Yes Yes No. of Conductors❸ 25 40 Mating 1762-L40x Embedded I/O Controller -L40AWA Outputs, -L40BWA Outputs, -L40BXB Outputs -L40AWA Inputs, -L40BWA Inputs, -L40BXB Inputs I/O Ready Cables for 1762-L40x Embedded I/O Controllers Cable Cat. No. 1492-CAB➋T62 1492-CAB➋X62 ❷ Standard Cable Lengths 1.0, 2.5, 5.0 m 1.0, 2.5, 5.0 m I/O ready cables are available in standard lengths or 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the catalog number (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m) Example: Catalog Number 1492-CABLE050RTBR is for a 5.0 m cable with a pre-wired Catalog Number 1746-RT25R RTB on one end. ❸ 1492-CAB➊T62 uses 18AWG wire and 1492-CAB➊X62 uses 22AWG wire. MicroLogix 1500 Base Unit I/O to IFM Selection Tables Bulletin 1764, Base Units I/O and Compatible 20-Terminal 1492-IFMs Description of 20-PIN IFM BWA Outputs C64 C64 C64 AWA Outputs Catalog Number for Wiring System Module with Fixed Terminal Block Catalog Number for Wiring System Module with Removable Terminal Block Socket Assembly (order plugs separately 1764 Base Unit I/O BXB Outputs F64 F64 F64 BWA Inputs A64 A64 A64 AWA Inputs BXB Inputs B64 B64 B64 Feed-through Standard 264Vac/dc Max. Narrow standard 132Vac/dc Max. With Extra terminals (2 per I/O) 264Vac/dc Max. ❶ ➋ 1492-IFM20F❶ 1492-IFM20FN ❶ 1492-RIFM20F❶➋ 1492-RIFM20FN ❶➌ A64 A64 A64 C64 C64 C64 1492-IFM20F-2❶ 1492-RIFM20F02❶➋ When using this IFM module with the base I/O of the 1762 controller, the current rating of the ouputs must be considered. Refer to appendix A Compatible Removablae Terminal Block (RTB) 1492-RTB20N (screw style terminal) or 1492-RTB20P (push-in style terminal, available March 2006). ORDER PLUGS SEPARATELY. ➌ Compatible Removable Terminal Block (RTB) plug; 1492-RTB10N (screw style terminals) or 1492-RTB10P (push-in style terminals, available March 2006. ORDER PLUGS SEPARATELY. These pre-wired cables have a pre-wired removable terminal block (RTB) on one end to connect to the front of the Bulletin 1764 base unit digital I/O and a connector on the other end to plug into a 20-terminal IFM. You must first select the IFM from the preceding selection table. Pre-Wired Cables for 1764 Base I/O I/O Ready Cable Cat. No. 1492-CAB➊A64 1492-CAB➊B64 1492-CAB➊C64 1492-CAB➊F64 Standard Cable Lengths 0.5, 1.0, 2.5, 5.0 0.5, 1.0, 2.5, 5.0 0.5, 1.0, 2.5, 5.0 0.5, 1.0, 2.5, 5.0 Build-to-Order Available Yes Yes Yes Yes No. of Conductors 20 20 20 20 Mating 1764 Base Unit I/O AWA Inputs, BWA Inputs BXB Inputs AWA Outputs, BWA Outputs BXB Output ➊ Pre-wired cables are available in standard lengths of 0.5 m, 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the catalog number (005 = 0.5 m, 010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Catalog Number 1492-CAB005A64 is for a 0.5 m cable that could be used to connect a Catalog Number 1492-IFM20F to a Cat. No. 1764-AWA Input. Publication 1492-TD008D-EN-P - January 2009 Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems 45 Selection Tables, Continued The I/O module-ready cables have a pre-wired RTB on one end to plug onto the front of the Bulletin 1764 base unit I/O and 20 individually colored conductors on the other end. These cables provide the convenience of prewired connections at the base unit I/O end, while still allowing the flexibility to field-wire to standard terminal blocks of your choice. Build-to-Order Available Yes Yes Yes Yes No. of Conductors 20❸ 20❸ 20❹ 20❹ Mating 1764 Base Unit I/O AWA Outputs, BWA Outputs BXB Outputs AWA Inputs, BWA Inputs BXB Inputs I/O Ready Cables for 1764 Base I/O Cable Cat. No. 1492-CAB➋T64 1492-CAB➋U64 1492-CAB➋W64 1492-CAB➋X64 Standard Cable Lengths 1.0, 2.5, 5.0 m 1.0, 2.5, 5.0 m 1.0, 2.5, 5.0 1.0, 2.5, 5.0 ➋ I/O ready cables are available in standard lengths or 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the catalog number (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m) Example: Catalog Number 1492-CABLE050RTBR is for a 5.0 m cable with a pre-wired Catalog Number 1746-RT25R RTB on one end. ➌ Uses #18 AWG wire. ➍ Uses #22 AWG wire. Using Bulletin 1769 Selection Tables to Make Valid 1492 Wiring System Module Catalog Numbers Follow these steps when using the selection tables to make valid catalog numbers: 1. Find the appropriate table based on the catalog number of the 1769 I/O module. 2. Find the column in the selected table for the 1769 I/O module. 3. Follow the column down to determine which Wiring System Modules are compatible with the I/O module as indicated by letter code. If there is no letter code, the Wiring System Module is not compatible with the I/O module. NOTE: The letter codes designate the compatible 1492 cable for that 1769 I/O and Wiring System Module combination. 4. Select the desired Wiring System Module. 5. Configure the cable catalog number using 1492-CAB➊ (for digital cables) or 1492-ACAB➊ (for analog cables). See footnote ➊ on pages 50 and 53. Bulletin 1769 Compact I/O for CompactLogix and MicroLogix 1500 IFMs and Cables Bulletin 1769 Digital 8 and 16-Point I/O Modules ➌ Description of 20-PIN IFM OW16 M69 M69 M69 — Cat. No. for Wiring System Module with Fixed Terminal Block Cat. No. for Wiring System Module with Removable Terminal Block Socket Assembly (order plugs separately 1492-RIFM20F➐ 1492-RIFM20FN➑ 1492-RIFM20F-2➐ — I/O Module Catalog Number 1769-… OW8I D69 — — — IQ16F OA16 OB16 OV16 E69 E69 E69 — IM12 OW8 C69 C69 C69 — IA16 IQ16 OA8 OB8 L69 L69 L69 — IA8I F69 F69 — — Feed-through Standard 264V AC/DC Max. Narrow standard 132V AC/DC Max. Extra terminals (2 per I/O) 264V AC/DC Max. 3-wire sensor type input devices 132V AC/DC Max. 1492-IFM20F 1492-IFM20FN 1492-IFM20F-2 1492-IFM20F-3 A69 A69 A69 A69 B69 B69 B69 B69 B69 B69 B69 B69 G69 — G69 — C69 C69 C69 — M69 M69 M69 — E69 E69 E69 — Note: Footnotes are on the following page. Publication 1492-TD008D-EN-P - January 2009 and 24V AC/DC blown fuse indicators Two 4-point isolated groups with four terminals/input and 24V AC/DC blown fuse LED indicators 8 Individually isolated with extra terminals output. and 120V AC/DC blown fuse LED indicators 8 Individually isolated with four terminals/output and 120V AC/DC blown fuse LED indicators Two 4-point isolated groups with four terminals/input and 120V AC/DC blown fuse indicators 8 Individually isolated with four terminals/output and 240V AC/DC blown fuse LED indicators Relay Master (LED Indicating) ➎➏ 20-pin master with eight (8) 24V DC relays 20-pin master with eight (8) 120V AC relays 20-pin master with sixteen (16) 24V DC relays with fusing 20-pin master with sixteen (16) 24V DC relays with fusing 20-pin master with sixteen (16) 120V AC relays 20-pin master with sixteen (16) 120V AC relays with fusing 1492-IFM20D24 1492-IFM20D24N 1492-IFM20D120 ➍ 1492-IFM20D120N 1492-IFM20D24-2 1492-IFM20D24A-2 1492-IFM20D120-2 1492-IFM20D120A-2 1492-IFM20D24-3 1492-IFM20DS24-4 1492-IFM20DS120-4 1492-IFM20D240-2 1492-IFM20D240A-2 — — A69 A69 — — — A69 — — — — — B69 B69 — — — B69 — — B69 — — — — B69 B69 — — — B69 — — B69 — — — — — — — — — — — — — — — — G69 — — — — — — — — — — C69 — — — — M69 H69 — — M69 — — — — M69 — E69 E69 — — E69 — — — — — — — — 1492-IFM20F-F-2 1492-IFM20F-F24-2 1492-IFM20F-F120-2 1492-IFM20F-F240-2 1492-IFM20F-F24A-2 1492-IFM20F-F120A-2 1492-IFM20F-FS-2 1492-IFM20F-FS24-2 14792-RIFM20F-F-2➐ 1492-IFM20F-F24-2➐ 1492-RIFM20F-F120-2➐ — 1492-RIFM20F-F24A-2➐ 1492-RIFM20F-F120A02➐ — — — — — — — — — — — — — — — A69 — — — — — — B69 ➊ — — — — — — — B69 ➊ — — — — — — — — — — — — — — — — — C69 — M69 — M69 — — — — — E69 E69 — — — — — — 1492-IFM20F-FS24A-4 — — — — — — — — — 1492-IFM20F-FS120-2 — — — — — — C69 — — 1492-IFM20F-FS120-4 — — — — — — C69 — — 1492-IFM20F-FS120A-4 — — — — — — — — — 1492-IFM20F-FS240-4 — — — — — — — — — 1492-XIM2024-8R➒ 1492-XIM20120-8R➓ 1492-XIM2024-16R 1492-XIM2024-16RF 1492-XIM20120-16R 1492-XIM20120-16RF — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — H69 — — H69 H69 E69 — E69 E69 — — Publication 1492-TD008D-EN-P . No. No. for Wiring System Module with Removable Terminal Block Socket Assembly (order plugs separately — — — — — — — — — — — — — I/O Module Catalog Number 1769-… OW16 M69 H69 M69 H69 M69 — M69 — — — — M69 — M69 M69 M69 — — — — — — — — — — — — — — — — OW8I — — — — — — — — — D69 D69 — — — — — — — — D69 D69 — D69 D69 — D69 — — — — — — IQ16F OA16 OB16 OV16 E69 — — — E69 — — — — — — — — E69 E69 — — E69 — — — — — — — — — — — — — — IM12 OW8 — — — — — — — — — C69 C69 — — — — — — — — C69 C69 — C69 C69 — — — — — — — — IA16 IQ16 OA8 OB8 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — IA8I — — — — — — — — — — — — — LED Indicating Standard with 24V AC/DC LEDs Narrow standard with 24V AC/DC LEDs Standard with 120V AC/DC LEDs Narrow standard with 120V AC LEDs 24V AC/DC LEDs and extra terminals for outputs 24V AC/DC LEDs and extra terminals for inputs 120V AC LEDs and extra terminals for outputs 120V AC LEDs and extra terminals for inputs 3-wire sensor with 24V AC/DC LEDs 8 Individually isolated with 24/48V AC/DC LEDs and 4 terminals/output 8 Individually isolated with 120V AC LEDs and 4 terminals/output 240V AC LEDs and extra terminals for outputs 240V AC LEDs and extra terminals for inputs Fusible 120V AC/DC with extra terminals for outputs Extra terminals with 24V AC/DC blown fuse LED indicators Extra terminals with 120V AC/DC blown fuse LED indicators Extra terminals with 240V AC/DC blown fuse LED indicators Extra terminals with 24V AC/DC blown fuse LED indicators Extra terminals with 120V AC/DC blown fuse LED indicators 8 Individually isolated 120V AC/DC with extra terminals for outputs 8 Individually isolated with extra terminals output.46 Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems Bulletin 1769 Digital 8 and 16-Point I/O Modules (Continued)➌ Description of 20-PIN IFM Cat. for Wiring System Module with Fixed Terminal Block Cat.January 2009 . January 2009 . for Wiring System Module with Fixed Terminal Block Cat.Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems 47 Bulletin 1769 Digital 8 and 16-Point I/O Modules (Continued)➌ Description of 20-PIN IFM Cat. No. Publication 1492-TD008D-EN-P . and 120V AC/DC blown fuse LED indicators 8 Individually isolated with four terminals/output and 120V AC/DC blown fuse LED indicators Two 4-point isolated groups with four terminals/input and 120V AC/DC blown fuse indicators 8 Individually isolated with four terminals/output and 240V AC/DC blown fuse LED indicators Relay Master (LED Indicating) ➎➏ 20-pin master with eight (8) 24V DC relays 20-pin master with eight (8) 120V AC relays 20-pin master with sixteen (16) 24V DC relays with fusing 20-pin master with sixteen (16) 24V DC relays with fusing 20-pin master with sixteen (16) 120V AC relays 20-pin master with sixteen (16) 120V AC relays with fusing 1492-IFM20D24 1492-IFM20D24N 1492-IFM20D120 ➍ 1492-IFM20D120N 1492-IFM20D24-2 1492-IFM20D24A-2 1492-IFM20D120-2 1492-IFM20D120A-2 1492-IFM20D24-3 1492-IFM20DS24-4 1492-IFM20DS120-4 1492-IFM20D240-2 1492-IFM20D240A-2 — — A69 A69 — — — A69 — — — — — B69 B69 — — — B69 — — B69 — — — — B69 B69 — — — B69 — — B69 — — — — — — — — — — — — — — — — G69 — — — — — — — — — — C69 — — — — M69 H69 — — M69 — — — — M69 — E69 E69 — — E69 — — — — — — — — 1492-IFM20F-F-2 1492-IFM20F-F24-2 1492-IFM20F-F120-2 1492-IFM20F-F240-2 1492-IFM20F-F24A-2 1492-IFM20F-F120A-2 1492-IFM20F-FS-2 1492-IFM20F-FS24-2 14792-RIFM20F-F-2➐ 1492-IFM20F-F24-2➐ 1492-RIFM20F-F120-2➐ — 1492-RIFM20F-F24A-2➐ 1492-RIFM20F-F120A02➐ — — — — — — — — — — — — — — — A69 — — — — — — B69 ➊ — — — — — — — B69 ➊ — — — — — — — — — — — — — — — — — C69 — M69 — M69 — — — — — E69 E69 — — — — — — 1492-IFM20F-FS24A-4 — — — — — — — — — 1492-IFM20F-FS120-2 — — — — — — C69 — — 1492-IFM20F-FS120-4 — — — — — — C69 — — 1492-IFM20F-FS120A-4 — — — — — — — — — 1492-IFM20F-FS240-4 — — — — — — — — — 1492-XIM2024-8R➒ 1492-XIM20120-8R➓ 1492-XIM2024-16R 1492-XIM2024-16RF 1492-XIM20120-16R 1492-XIM20120-16RF — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — H69 — — H69 H69 E69 — E69 E69 — — Note: Footnotes are on the following page. for Wiring System Module with Removable Terminal Block Socket Assembly (order plugs separately — — — — — — — — — — — — — I/O Module Catalog Number 1769-… OW16 M69 H69 M69 H69 M69 — M69 — — — — M69 — M69 M69 M69 — — — — — — — — — — — — — — — — OW8I — — — — — — — — — D69 D69 — — — — — — — — D69 D69 — D69 D69 — D69 — — — — — — IQ16F OA16 OB16 OV16 E69 — — — E69 — — — — — — — — E69 E69 — — E69 — — — — — — — — — — — — — — IM12 OW8 — — — — — — — — — C69 C69 — — — — — — — — C69 C69 — C69 C69 — — — — — — — — IA16 IQ16 OA8 OB8 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — IA8I — — — — — — — — — — — — — LED Indicating Standard with 24V AC/DC LEDs Narrow standard with 24V AC/DC LEDs Standard with 120V AC/DC LEDs Narrow standard with 120V AC LEDs 24V AC/DC LEDs and extra terminals for outputs 24V AC/DC LEDs and extra terminals for inputs 120V AC LEDs and extra terminals for outputs 120V AC LEDs and extra terminals for inputs 3-wire sensor with 24V AC/DC LEDs 8 Individually isolated with 24/48V AC/DC LEDs and 4 terminals/output 8 Individually isolated with 120V AC LEDs and 4 terminals/output 240V AC LEDs and extra terminals for outputs 240V AC LEDs and extra terminals for inputs Fusible 120V AC/DC with extra terminals for outputs Extra terminals with 24V AC/DC blown fuse LED indicators Extra terminals with 120V AC/DC blown fuse LED indicators Extra terminals with 240V AC/DC blown fuse LED indicators Extra terminals with 24V AC/DC blown fuse LED indicators Extra terminals with 120V AC/DC blown fuse LED indicators 8 Individually isolated 120V AC/DC with extra terminals for outputs 8 Individually isolated with extra terminals output. and 24V AC/DC blown fuse indicators Two 4-point isolated groups with four terminals/input and 24V AC/DC blown fuse LED indicators 8 Individually isolated with extra terminals output. No. 1492-RTB20N (screw style terminals) or 1492-RTB20P (push-in style terminals). No. ➍ This IFM is not recommended for use with PLC I/O modules that have an off-state leakage current exceeding 0. 025 = 2. ➌ Cables are available in standard lengths of 0.48 Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems Bulletin 1769 Digital 8 and 16-Point I/O Modules (Continued)➌ Description of 20-PIN IFM Cat.5 m. and 5. For relay contact ratings. insert the code for the desired cable length into the catalog number 005 = 0. and the letter A. Use 1492-IFM20D120-2 for outputs. — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — ➋ ➋ — — ➋ — — — — — — — — ➋ ➋ ➊ In the input module’s sink mode only. 1492-RTB12N (screw style terminals) or 1492-RTB12P (push-in style terminals). for Wiring System Module with Fixed Terminal Block Cat. for Wiring System Module with Removable Terminal Block Socket Assembly (order plugs separately 1492-RXIM24-8R✱ — — — — I/O Module Catalog Number 1769-… OW16 — — — — — — OW8I — — — — — — IQ16F OA16 OB16 OV16 — — — — — — IM12 OW8 — — — — — — IA16 IQ16 OA8 OB8 — — — — — ➋ IA8I Relay Expander (LED Indicating) ➎➏ Expander with eight (8) 24V DC relays 1492-XIM24-8R 1492-XIM120-8R Expander with eight (8) 120V AC relays Fusible Expander 1492-XIMF-F24-2 8-channel expander with 24V DC blown fuse indicators 1492-XIMF-F120-2 8-channel expander with 120V AC blown fuse indicators Feed-through Expander 1492-XIMF-2 Expander with eight (8) feed-through channels 132V AC/DC max. ➓ Expandable to 16 using XIM120-8R or XIMF-24-2.5 m. Use a 1492-IFM20D120N or 1492-IFM20D120A-2 for inputs.5 m 1.0 m. ➋ One expander module is connected to a master to provide a total of 16 outputs. ➑ Compatible Removable Terminal Block (RTB) plug. ORDER PLUGS SEPARATELY. Publication 1492-TD008D-EN-P . 1492-RTB10N (screw style terminals) or 1492-RTB10P (push-in style terminals).0 m.5 mA. ORDER PLUGS SEPARATELY.5 m (010 = 1. ➐ Compatible Removable Terminal Block (RTB) plug. and insert the letter in the box. Example: Catalog Number 1492-CABLE050A is for a 5. 2. ✱ Compatible Removable Terminal Block (RTB) plug.0 m.0 m). ORDER PLUGS SEPARATELY. and 050 = 5. ➏ The LED indicates the PLC output status. No. An extender cable is included with each expander to connect it to the master. ➎ The voltage rating is relay control/coil voltage. refer to page 192. ➒ Expandable to 16 using XIM24-8R or XIMF-24-2. To order.0 m cable.January 2009 . for Wiring System Module with Removable Terminal Block Socket Assembly (order plugs separately 1492-RIFM40F➏ 1492-RIFM40F-2➏ — 1492-RIFM40D24➏ — 1492-RIFM40D24A-2➏ — — — — — — — — I/O Module Catalog Number 1769-… IQ32 IQ32T OB32 OB32T OV32T Feed-through Standard 132V AC/DC Max. No. Continued Bulletin 1769 Digital 32-Point I/O Modules ➊ Description of 40-PIN IFM Cat. for Wiring System Module with Fixed Terminal Block Cat.January 2009 . 1492-IFM40F 1492-IFM40F-2 1492-IFM40F-3 1492-IFM40D24 1492-IFM40D24-2 1492-IFM40D24A-2 1492-IFM40D120-2 1492-IFM40D120A-2 1492-IFM40D24-3 1492-IFM40DS24-4 1492-IFM40DS24A-4 1492-IFM40DS120-4 1492-IFM40DS120A-4 1492-IFM40DS240A-4 J69 J69 J69 J69 — J69 — — J69 — — — — — H H H H — H — — H — — — — — K69 K69 — K69 K69 — — — — — — — — — H H — H H — — — — — — — — — H H — H H — — — — — — — — — 1492-IFM40F-F-2 1492-IFM40F-F24-2 1492-IFM40F-F120-2 1492-IFM40F-FS-2 1492-IFM40F-FS24-2 1492-IFM40F-FS24-4 1492-IFM40F-FS-4 1492-IFM40F-FS120-2 1492-IFM40F-FS120-4 1492-IFM40F-FS240-4 1492-IFM40F-FS24A-4 1492-IFM40F-FSA-4 1492-IFM40F-FS120A-4 1492-IFM40F-FS240A-4 — 1492-RIFM40F-F24-2➏ — — — — — 1492-RIFM40F-FS120-2➏ 1492-RIFM-FS120-4❼ — — — 1492-RIFM40F-FS120A4❼ — — — — — — — — — — — — — — — — — — — — — — — — — — — — — K69 K69 — — — — — — — — — — — — H H — — — — — — — — — — — — H H — — — — — — — — — — — — 1492-XIM4024-8R 1492-XIM4024-16R — 1492-RXIM4024-16R➑ — — — — K69 K69 H H — — Publication 1492-TD008D-EN-P . No. Extra terminals (2 per I/O) 132V AC/DC Max. LED Indicating Standard with 24V AC/DC LEDs 24V AC/DC LEDs and extra terminals for outputs 24V AC/DC LEDs and extra terminals for inputs 120V AC LEDs and extra terminals for outputs 120V AC LEDs and extra terminals for inputs 3-wire sensor with 24V AC/DC LEDs 16 Individually isolated with 24/48V AC/DC LEDs and 4 terminals/output 16 Individually isolated with 24V AC/DC LEDs and 4 terminals/input 16 Individually isolated with 120V AC LEDs and 4 terminals/output 16 Individually isolated with 120V AC LEDs and 4 terminals/input 16 Individually isolated with 240V AC LEDs and 4 terminals/input Fusible 120V AC/DC with extra terminals for outputs Extra terminals with 24V AC/DC blown fuse indicators for outputs Extra terminals with 120V AC/DC blown fuse indicators 16 Individually isolated with extra terminals for 120V AC/DC outputs 16 Individually isolated with extra terminals and 24V AC/DC blown fuse indicators 16 Individually isolated with 24V AC/DC blown fuse indicators and 4 terminals/output 16 Individually isolated 240V AC/DC with 4 terminals/output 16 Individually isolated with extra terminals and 120V blown fuse indicators 16 Individually isolated with 120V AC/DC blown fuse indicators and 4 terminals/output 16 Individually isolated with 240V AC/DC blown fuse indicators and 4 terminals/output 16 Individually isolated with 24V AC/DC blown fuse indicators and 4 terminals/input 16 Individually isolated 120V AC/DC with 4 terminals/input 16 Individually isolated with 120V AC/DC blown fuse indicators and 4 terminals/input 16 Individually isolated with 240V AC/DC blown fuse indicator and 4 terminals/input Relay Master (LED Indicating) ➍➎ 40-pin master with eight (8) 24V DC relays 40-pin master with sixteen (16) 24V DC relays Note: Footnotes are on the following page.Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems 49 Bulletin 1769 Compact I/O for CompactLogix and MicroLogix 1500 IFMs and Cables. 3-wire sensor type input devices 60V AC/DC Max. 0. 2.5. -OV16 1769-IA8I 1769-IM12 1769-OA16.5 m (010 = 1. Bulletin 1769 Compact I/O for CompactLogix and MicroLogix 1500 IFMs and Cables. 1.5.5.0 m). and insert the letter in the box. ORDER PLUGS SEPARATELY. and the letter A.0. No.0. 5.0 m 0.5.5. -OW16 (IFM modules with single common) 1769-IQ32 1769-OB32 Publication 1492-TD008D-EN-P . 2. ➍ The voltage rating is relay control/coil voltage. To order. 1. 5. ORDER PLUGS SEPARATELY. ➏ Compatible Removable Terminal Block (RTB) plug.0.0 m cable. 1492-RTB17N (screw style terminals) or 1492-RTB17P (push-in style terminals). 1. max. insert the code for the desired cable length into the catalog number 005 = 0. or less).5 m. 2. Pre-Wired Cables for Bulletin 1769 Digital I/O Modules Cable Cat.0. You must first select the IFM/XIM from the preceding selection table.5. 1.5. and 5. 2. ➎ The LED indicates the PLC output status.5. 1.5.5.0 m 0.5. Example: Catalog Number 1492-CABLE050A is for a 5.50 Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems Bulletin 1769 Digital 32-Point I/O Modules (Continued)➊ Description of 40-PIN IFM Cat.5.5. 5. ➒ Compatible Removable Terminal Block (RTB) plug. ❼ Compatible Removable Terminal Block (RTB) plug. Extender cable is provided.5. 2. -OW8 1769-OW8I 1769-OB16.5. 2. 1.0 m 0.0 m 0. 5. 025 = 2. for Wiring System Module with Fixed Terminal Block 1492-XIM4024-16RF Cat. 1.0.0 m 0.5.or 40-terminal IFM/XIM. For relay contact ratings. 1.0.). 2. 1492-RTB12N (screw style terminals) or 1492-RTB12P (push-in style terminals).0 m 0. No. 2. 1492-CAB➊A69 1492-CAB➊B69 1492-CAB➊C69 1492-CAB➊D69 1492-CAB➊E69 1492-CAB➊F69 1492-CAB➊G69 1492-CAB➊H69 1492-CAB➊J69 1492-CAB➊K69 Standard Cable Lengths 0.0 m 0.0 m. Continued These pre-wired cables have a pre-wired RTB on one end to connect to the front of a Bulletin 1769 digital I/O module and a connector on the other end to plug into a 20. 5.0 m. 5.0 m Build-to-Order Available Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No.January 2009 . ORDER PLUGS SEPARATELY. 5. 5. 2. ➋ Can have 2 or 3 expander modules depending on master used (32 pts. of Conductors 20 20 20 20 20 20 20 20 40 40 Mating 1769 I/O Module Catalog Number 1769-IA16 1769-IQ16 1769-OA8.5.0. 1.5. refer to page 192. 1492-RTB14N (screw style terminals) or 1492-RTB14P (push-in style terminals). 5. ➌ One 1492-XIM24-16RF is to be used with one 1492-XIM4024-16R or 1492-XIM4024-16RF master (32 pts.5. 5.5.0 m 0.0. 2. No.5.0 m 0. 1. and 050 = 5. 2.0.5. ➑ Compatible Removable Terminal Block (RTB) plug. 1. for Wiring System Module with Removable Terminal Block Socket Assembly (order plugs separately — I/O Module Catalog Number 1769-… IQ32 — IQ32T — OB32 K69 ➋ — ➋ — ➌ ➋ OB32T H ➋ — ➋ — ➋ ➋ — — OV32T — 40-pin master with sixteen (16) 24V DC relays with fusing Relay Expander (LED Indicating) ➍➎ Expander with eight (8) 24V DC relays Expander with eight (8) 120V AC relays Fusible Expander 8-channel expander with 24V DC blown fuse indicators 8-channel expander with 120V AC blown fuse indicators Expander with sixteen (16) 24V DC relays with fusing Feed-through Expander Expander with eight (8) feed-through channels 1492-XIM24-8R 1492-XIM120-8R 1492-XIMF-F24-2 1492-XIMF-F120-2 1492-XIM24-16RF 1492-RXIM24-8R➒ — — — — — — — — — — — — — — — — 1492-XIMF-2 — — — — ➊ Cables are available in standard lengths of 0. 1492-RTB20N (screw style terminals) or 1492-RTB20P (push-in style terminals). ORDER PLUGS SEPARATELY.0. 5. I/O Module-Ready Cables for Bulletin 1769 Digital I/O Modules ➍ Cable Catalog Number 1492-CAB➌RTN10 1492-CAB➌RTN18 Standard Cable Lengths 1.0. 1.5.5.5 m cable that can be used to connect a Catalog Number 1492-IFM20D24N IFM to a Catalog Number 1769-OB16 I/O module.0 m 0.0 m ➋ 1492-CAB➌ RTN32I and 1492-CAB➌ RTN320 cables use 22 AWG wire. 2.Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems 51 Pre-Wired Cables for Bulletin 1769 Digital I/O Modules (Continued) Cable Cat. These cables provide the convenience of pre-wired connections at the I/O module end.0. -OV32T ➊ Cables are available in standard lengths of 0.5. 2.5 m.0. ➌ Cables are available in standard lengths of 1. 2. 2.0 m 1. The I/O module-ready cables have a pre-wired RTB on one end to plug onto the front of a Bulletin 1769 I/O module and 20 individually colored #18 AWG conductors on the other end. 5. 1492-CAB➊L69 1492-CAB➊M69 1492-CABLE➊H Standard Cable Lengths 0. 1. while still allowing the flexibility to field-wire to standard terminal blocks of your choice. -OB32T. To order. -OW8I. 5. -OW16 (IFM modules with multiple commons) 40 1769-IQ32T.5.0 m.0.5 m. -OV32T 1492-CAB➌RTN32I 1. -OB8 1769-IQ32 1769-OB32 1769-IQ32T. 1.0 m. Example: Catalog Number 1492-CAB005E69 is for a 0.0 m. 010 = 1.5. 025 = 2.0 m Build-to-Order Available Yes Yes Yes Yes Yes No.5. ➍ Discrete I/O ready cables should not be used with PLC analog I/O modules as a cable shield and drain wires are not provided.0 m. -OB32T. 2.0 m 1492-CABLE➌N3 1.0 m 0. -OB16.5 m.5 m. and 5. and 050 = 5.0 m. 5.0 m 1492-CAB➌RTN32O 1. -OW16. 2. insert the code for the desired cable length into the catalog number (010 = 1. 2.5. 2. of Conductors 12 20 40 ➋ 40 ➋ 40 ➋ Mating 1769 I/O Module Catalog Number 1769-OA8.0 m). To order.0 m. 1.0. No. -IQ16F. 2. Publication 1492-TD008D-EN-P . -OW8 1769-IA8I. and 050 = 5.0. -OA16. -IQ16.5. -IA16. 5.0 m).January 2009 .5. 5. -OV16. -IM12. 2. 025 = 2.0 m Build-to-Order Available Yes Yes Yes No. Example: Catalog Number 1492-CAB050RTN10 is for a 5.5 m.5 m. 5.5. and 5.0.0 m cable with a wired Catalog Number 1746-RTBN10 on one end. 5. of Mating 1769 Conductors I/O Module Catalog Number 20 1769-OB8 20 1769-OA16.5.0. insert the code for the desired cable length into the catalog number (005 = 0. 52 Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems Bulletin 1769 Compact I/O for CompactLogix and MicroLogix 1500 AIFMs and Cables IFMs for Bulletin 1769 Analog I/O Modules➊ Description of AIFM IF4 (Single-Ended Voltage) IF8 (Single-Ended Voltage) IF4 (Single-Ended Current) IF8 (Single-Ended Current) IF4XOF2 or IF4FXOF2F (Cur In & Out) IF4XOF2 or IF4FXOF2F (Volt In & Out) IF4XOF2 or IF4FXOF2F (Cur In & Volt Out) IF4 (Differential Voltage) IF8 (Differential Voltage) IF4 (Differential Current) IF8 (Differential Current) Catalog Number for Wiring System Module with Fixed Terminal Block Catalog Number for Wiring System Module with Removable Terminal Block Socket Assembly (order plugs separately I/O Module Catalog Number 1769-… HSC (Differential) OF2 (Voltage) AA69 — — Feed-through 4-channel input. and the letters BA.0 m). and 050 = 5. ORDER PLUGS SEPARATELY. 5 terminals/channel 4-input/4-output channel with 1492-AIFMQS 8 fuses and 24V DC blown fuse indicators 1492-RAIFM4-3➋ 1492-RAIFM6S-3➌ 1492-RAIFM8-3➍ — — — BA69 — — — — EA69 BB69 — — — — EB69 BC69 — — — — EC69 BD69 — — — — ED69 — — — — CA69 CB69 CC69 C69 — — — — — — — — — — — — — — — — — — — — HA69 — — — — — — — — — — — — — — HA69 — — — — — — — — — — — — — — — BA69 — BB69 — BC69 — BD69 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — EA69 — — — — — — — EB69 — — — — — — — EC69 — — — — — — — ED69 CA69 CB69 CC69 — — — — — — — — — — — — — — — — — — — — ➊ Cables are available in standard lengths of 0.5 m. 025 = 2. 2. ➍ Compatible Removable Terminal Block (RTB) plug. and 5. test points.1492-AIFM4-3 out combination with 3 terminals/channel 6-channel isolated with 1492-AIFM6S-3 3…4 terminals/channel 8. 3 terminals/channel 16-channel input with 24V DC 1492-AIFM16-F-5 blown fuse indicators. and insert the letter in the box. insert the code for the desired cable length into the catalog number 005 = 0. test points.0 m.5 m (010 = 1. 5 terminals/input 3 terminals/output 2-channel input. 1492-RTB12N (screw style terminals) or 1492-RTB12P.0 m. Publication 1492-TD008D-EN-P .5 m cable. ➌ Compatible Removable Terminal Block (RTB) plug. ➋ Compatible Removable Terminal Block (RTB) plug.or 16-channel input or output 1492-AIFM8-3 with 3 terminals/channel Thermocouple 6-channel with 1492-AIFM6TC-3 3 terminals/channel High-Speed Counter/Encoder 2-channel counter input/4 1492-AIFMCE4 outputs Fusible High-Speed Counter/Encoder 2-channel fused counter input/4 1492-AIFMCE4-F fused outputs Fusible Analog 4-channel with 24V DC blown 1492-AIFM4I-F-5 fuse indicators. Example: Catalog Number 1492-ACAB025BA69 is for a 2. 3 terminals/output 8-channel input with 24V DC 1492-AIFM8-F-5 blown fuse indicators.0 m.5 m 1. ORDER PLUGS SEPARATELY.5 m. 1492-RTB16N (screw style terminals) or 1492-RTB16P. To order. output or 2-in/2. 1492-RTB8N (screw style terminals) or 1492-RTB8P. 2-channel 1492-AIFM4C-F-5 output with 24V DC blown fuse indicators. 5 terminals/channel 16-channel input with 24V DC 1492-AIFM16-F-3 blown fuse indicators. 5 terminals/input. ORDER PLUGS SEPARATELY.January 2009 OF8V (Voltage) OF2 (Current) OF8C (Current) — AB69 — — D69 — — — D69 — — — — — — — — — — — — — — — — — — — — — — — — — — — IR6 . 2. 5.0 m 0. and 5.5. 2.0.0 m 0. 5.0 m 0.or 25-pin D-shell terminal AIFM.5.0. 2. 3.5 m.5.5.5.5. 5. 1. Publication 1492-TD008D-EN-P .0 m 0. 1.5. NOTE: The letter codes designate the compatible 1492 cable for that 1794 I/O and 1492 Wiring System Module combination.0 m Build-to-Order Available Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes AIFM Connector 15-pin D-shell 15-pin D-shell 15-pin D-shell 15-pin D-shell 15-pin D-shell 15-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell Mating 1769 I/O Module Catalog Number 1769-OF2 Voltage 1769-OF2 Current 1769-IF4 Single-Ended Voltage 1769-IF4 Single-Ended Current 1769-IF4 Differential Voltage 1769-IF4 Differential Current 1769-IR6 Resist. 5.0. 1. 1. Follow the column down to determine which Wiring Systems Modules are compatible with the I/O module as indicated by letter code.5 m cable. 1.0. 2.0.5. 1.January 2009 . 2.0. 5.5.5.0.Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems 53 These pre-wired cables have a pre-wired RTB on one end to connect to the front of a Bulletin 1769 analog I/O module and a connector on the other end to plug into a 15.0 m. 1. To order. If there is no letter code. 2. 1.5. 4.0. 1.5 m.0 m 0. 1. Temperature Detector 1769-IF4XOF2 or -IF4FXOF2F (Cur In & Out) 1769-IF4XOF2 or -IF4FXOF2F (Volt In & Out) 1769-IF4XOF2 or -IF4FXOF2F (Cur In & Volt Out) 1769-OF8C. 5. 2.5. Pre-Wired Cables for Bulletin 1769 Analog I/O Modules Cable Catalog Number 1492-ACAB➊AA69 1492-ACAB➊AB69 1492-ACAB➊BA69 1492-ACAB➊BB69 1492-ACAB➊BC69 1492-ACAB➊BD69 1492-ACAB➊C69 1492-ACAB➊CA69 1492-ACAB➊CB69 1492-ACAB➊CC69 1492-ACAB➊D69 1492-ACAB➊EA69 1492-ACAB➊EB69 1492-ACAB➊EC69 1492-ACAB➊ED69 1492-ACAB➊HA69 Standard Cable Lengths 0. 2.0 m). Selection Tables Using Bulletin 1794 Selection Tables to Make Valid 1492 Wiring System Module Catalog Numbers Follow these steps when using the selection tables to make valid catalog numbers: Note: I/O modules must use Flex D-shell base cat.0 m 0.5. 5. 2. 2. 025 = 2.0.0.5.5.0. 010 = 1.0 m. See footnote ➊ on page 57.5.0 m 0.5. the 1492 Wiring System Module is not compatible with the I/O module. Note: Footnotes are on the following page.0.5.5.5.5.0. 1769-OF8V 1769-IF8 Single-Ended Voltage 1769-IF8 Single-Ended Current 1769-IF8 Differential Voltage 1769-IF8 Differential Current 1769-HSC Counter/Encoder (Differential) ➊ Cables are available in standard lengths of 0. 1. Example: Catalog Number 1492-ACAB005➋ is for a 0.0 m 0. Find the appropriate table based on the catalog numbers of the 1794 I/O module. 1794-TB37DS or 1794-TB62DS. 5. 2. 5. Configure the cable catalog number using 1492-CAB➊ (for digital cables) or 1492-ACAB➊ (for analog cables). 2. Select the desired 1492 Wiring System Module. and 050 = 5. 5. You must first select the AIFM from the preceding selection table.5.5. 1.0 m 0.5.5. 2. 2. 2. Find the column for the 1794 I/O module. 2.5. 5.5. 1. 5. nos.0 m 0. 5. 1.5. 2.0.0 m 0. 5.5.5 m. 5.5.5 m. 5.5.0. 1. 2. insert the code for the desired cable length into the catalog number (005 = 0.0 m 0.0 m. 1. 1. 5.5. 1.0 m 0.0 m 0.0 m 0.0. Publication 1492-TD008D-EN-P . LED Indicating Standard with 24V AC/DC LEDs Narrow standard with 24V AC/DC LEDs Standard with 120V AC/DC LEDs Narrow standard with 120V AC LEDs 24V AC/DC LEDs and extra terminals for outputs 24V AC/DC LEDs and extra terminals for inputs 120V AC LEDs and extra terminals for outputs 120V AC LEDs and extra terminals for inputs 3-wire sensor with 24V AC/DC LEDs 8 Individually isolated with 24/48V AC/DC LEDs and 4 terminals/output 8 Individually isolated with 120V AC LEDs and 4 terminals/output 240V AC LEDs and extra terminals for outputs 240V AC LEDs and extra terminals for inputs Fusible 120V AC/DC with extra terminals for outputs Extra terminals with 24V AC/DC blown fuse LED indicators Extra terminals with 120V AC/DC blown fuse LED indicators Extra terminals with 240V AC/DC blown fuse LED indicators Extra terminals with 24V AC/DC blown fuse LED indicators Extra terminals with 120V AC/DC blown fuse LED indicators 8 Individually isolated 120V AC/DC with extra terminals for outputs 8 Individually isolated with extra terminals and 24V AC/DC blown fuse LED indicators Two 4-point isolated groups with four terminals/input and 24V AC/DC blown fuse LED indicators 8 Individually isolated with extra terminals output. and 120V AC/DC blown fuse LED indicators 8 Individually isolated with four terminals/output and 120V AC/DC blown fuse LED indicators Two 4-point isolated groups with four terminals/input and 120V AC/DC blown fuse indicators 8 Individually isolated with 4 terminals/output and 240V AC/DC blown fuse indicators 1492-IFM20F 1492-IFM20FN 1492-IFM20F-2 1492-IFM20F-3 A94 A94 A94 A94 A94 A94 A94 A94 A94 A94 A94 — A94 A94 A94 A94 A94 A94 A94 — A94 A94 A94 — A94 A94 A94 — A94 A94 A94 — A94 A94 A94 — A94 A94 A94 A94 A94 A94 — 1492-IFM20D24 1492-IFM20D24N 1492-IFM20D120 1492-IFM20D120N 1492-IFM20D24-2 1492-IFM20D24A-2 1492-IFM20D120-2 1492-IFM20D120A-2 1492-IFM20D24-3 1492-IFM20DS24-4 1492-IFM20DS120-4 1492-IFM20D240-2 1492-IFM20D240A-2 — — — — — — — — — — — — — — — — — — — — — — — — — — — A94 — — — A94 — — — — — — — — A94 — — — A94 — — — — — — — — — — — — — — — — — — — — — — — — — A94 — — — — — — — A94 A94 — — A94 — — — — — — — — A94 A94 — — A94 — — — — — — — — A94 A94 — — A94 — — — — — — — — A94 A94 — — A94 — — — — — — — — A94 — — — A94 — — — — — — — — — A94 A94 — — 1492-IFM20F-F-2 1492-IFM20F-F24-2 1492-IFM20F-F120-2 1492-IFM20F-F240-2 1492-IFM20F-F24A-2 1492-IFM20F-F120A-2 1492-IFM20F-FS-2 1492-IFM20F-FS24-2 1492-IFM20F-FS24A-4 1492-IFM20F-FS120-2 1492-IFM20F-FS120-4 1492-IFM20F-FS120A-4 1492-IFM20F-FS240-4 1492-RIFM20F-F-2 1492-RIFM20F-F24-2 1492-RIFM20F-F120-2 — 1492-RIFM20F-F24A-2 1492-RIFM20F-F120A-2 — — — — — — — 1492-RTB20✪ 1492-RTB20✪ 1492-RTB20✪ — 1492-RTB20✪ 1492-RTB20✪ — — — — — — — — — — — A94 — — — — — — — — — — — — A94 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — A94 A94 — — — — — — — — — — — A94 A94 — — — — — — — — — — — A94 A94 — — — — — — — — — — — A94 A94 — — — — — — — — — — — A94 A94 — — — — — — — — — — — A94 A94 — A94 — — — Note: Footnotes are on the following page. for Wiring System Module with Fixed Terminal Block Cat. No. Extra terminals (2 per I/O) 264V AC/DC Max.January 2009 OW8 — — — — — — — — — — — — — — IB16 IV16 OB8 IB8 . No.54 Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems Pre-Wired Cable and IFMs for Bulletin 1794 Digital 8-Point and 16-Point I/O Modules ➌ Description of 20-PIN IFM and Flex Distributed I/O IB10XOB6 Cat. for Wiring System Module with Removable Terminal Block Socket Assembly (order plugs separately 1492-RIFM20F 1492-RIFM20FN 1492-RIFM20F-2 — Cat. for Compatible Screw Style (N) and Push-in Style (P) RTB Plugs ➊ 1492-RTB20✪ 1492-RTB10✪ 1492-RTB20✪ — Flex Digital I/O Module — Uses D-Shell Base 1794-TB37DS OB8EP OB16P OV16P — A94 — — — A94 — — — — — — — — A94 A94 — — — — — — — — — — — OB16 OV16 Feed-through Standard 264V AC/DC Max. Narrow standard 132V AC/DC Max. No. 3-wire sensor type input devices 132V AC/DC Max. Plugs are available in screw style and push in style terminal types. indicates the number of connections/pole. No. and 050 = 5. for Wiring System Module with Removable Terminal Block Socket Assembly (order plugs separately) Cat. Extra terminals (2 per I/O) 132V AC/DC Max. No. No. for Compatible Screw Style (N) and Push-in Style (P) RTB Plug ➏ Flex Digital I/O Module — Uses D-Shell Base 1794-TB62DS… IB16XOB16P IB16D Feed-through Standard 132V AC/DC Max.5 m.0 m.5 m.Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems 55 Pre-Wired Cable and IFMs for Bulletin 1794 Digital 8-Point and 16-Point I/O Modules ➌ (Continued) Description of 20-PIN IFM and Flex Distributed I/O IB10XOB6 Cat. for Compatible Screw Style (N) and Push-in Style (P) RTB Plugs ➊ — — — — — — Flex Digital I/O Module — Uses D-Shell Base 1794-TB37DS OB8EP OB16P OV16P — — — — — — — — — — — B94 B94 — B94 B94 — — — — — — — — OB32P OB16 OV16 Relay Master (LED Indicating) ➎➏ 20-pin master with eight (8) 24V DC relays 20-pin master with eight (8) 120V AC relays 20-pin master with sixteen (16) 120V AC relays 20-pin master with sixteen (16) 120V AC relays with fusing 20-pin master relay with sixteen (16) 24V DC relays 20-pin master with sixteen (16) 24V DC relays with fusing Relay Expander (LED Indicating) ➎➏ Expander with eight (8) 24V DC relays Expander with eight (8) 120V AC relays Fusible Expander 8-channel expander with 24V DC blown fuse indicators 8-channel expander with 120V AC blown fuse indicators Feed-through Expander Expander with eight (8) feed-through channels 1492-XIM2024-8R 1492-XIM20120-8R 1492-XIM20120-16R 1492-XIM20120-16RF 1492-XIM2024-16R 1492-XIM2024-16RF — — — — — — — — — — — — — — — — — — — — — — — — A94 — — — A94 A94 A94 — — — A94 A94 A94 — — — — — — — — — — — — — — — — — 1492-XIM24-8R 1492-XIM120-8R 1492-XIMF-F24-2 1492-XIMF-F120-2 1492-RXIM24-8R — — — 1492-RTB12✪ — — — — — — — — — — — — — — — — — — — ➋ — ➋ — ➋ — ➋ — — — — — — — — — — — — — 1492-XIMF-2 — — — — — — ➋ ➋ — — — ➊ Order plugs separately (two plugs per catalog number). 3-wire sensor type input devices 60V AC/DC Max. for Wiring System Module with Fixed Terminal Block Cat.January 2009 IB32 OW8 — — — — — — — — — — — IB16 IV16 OB8 IB8 . 2. and insert the letter in the box. LED Indicating Standard with 24V AC/DC LEDs 24V AC/DC LEDs and extra terminals for outputs 24V AC/DC LEDs and extra terminals for inputs 120V AC LEDs and extra terminals for outputs 120V AC LEDs and extra terminals for inputs 3-wire sensor with 24V AC/DC LEDs 16 Individually isolated with 24/48V AC/DC LEDs and 4 terminals/output 16 Individually isolated with 24V AC/DC LEDs and 4 terminals/input 16 Individually isolated with 120V AC LEDs and 4 terminals/output 16 Individually isolated with 120V AC LEDs and 4 terminals/input 1492-IFM40D24 1492-IFM40D24-2 1492-IFM40D24A-2 1492-IFM40D120-2 1492-IFM40D120A-2 1492-IFM40D24-3 1492-IFM40DS24-4 1492-IFM40DS24A-4 1492-IFM40DS120-4 1492-IFM40DS120A-4 1492-RIFM40D24 — 1492-RIFM40D24A-2 — — — — — — — 1492-RTB20✪ — 1492-RTB20✪ — — — — — — — — — — — — — — — — — — — — — — — — — — — B94 — — — — — — — — — 1492-IFM40F 1492-IFM40F-2 1492-IFM40F-3 1492-RIFM40F 1492-RIFM40F-2 — 1492-RTB20✪ 1492-RTB20✪ — B94 B94 — B94 B94 — B94 B94 — Publication 1492-TD008D-EN-P . for Wiring System Module with Removable Terminal Block Socket Assembly (order plugs separately — — — — — — Cat.0 m.0 m cable. and 5. insert the code for the desired cable length into the catalog number 005 = 0.5 m (010 = 1. ➎ The voltage rating is relay control/coil voltage. Extender cable is provided. for Wiring System Module with Fixed Terminal Block Cat. and the suffix A94.0 m). No. To order. ➋ Can have up to one relay expansion module depending upon relay master used (total 16 points or less). 025 = 2. 20) in the cat.5 mA.e.0 m. The code for screw style is N and the code for push in style is P. ➍ This IFM is not recommended for use with PLC I/O modules that have an off-state leakage current exceeding 0. No. no. For Relay Contact Ratings. replace the ✪ in the catalog number with the code for the desired terminal style. Use 1492-IFM20D120-2 for outputs. Pre-Wired Cables and IFMs for Bulletin 1794 Digital 16-Point Isolated and 32-Point I/O Modules ➌ Description of 40-PIN IFM Cat. Example: Catalog Number 1492-CAB010A94 is for a 1. ➏ The LED indicates the PLC output status. Use a 1492-IFM20D120N or 1492-IFM20D120A-2 for inputs. ➌ Cables are available in standard lengths of 0.5 m 1. refer to page 192. To order. No. The number (i. 0 m. No.0 m. To order. No. indicates the number of connections/pole.0 m). and 5.5 m.56 Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems Pre-Wired Cables and IFMs for Bulletin 1794 Digital 16-Point Isolated and 32-Point I/O Modules (Continued)➌ Description of 40-PIN IFM Cat. An extender cable is included with each expander to connect it to the master. 025 = 2. no. For Relay Contact Ratings.e. Plugs are available in screw style and push in style terminal types. only).5 m (010 = 1. ➌ Cables are available in standard lengths of 0. Example: Catalog Number 1492-CAB010A94 is for a 1. 2. The number (i. ➎ The LED indicates the PLC output status. and insert the letter in the box.0 m cable. and 050 = 5. ➋ One 1492-XIM24-16RF is to be used with one 1492-XIM4024-16R AND 1492-XIM4024-16RF master (32 PT. No.0 m.5 m 1. for Compatible Screw Style (N) and Push-in Style (P) RTB Plug ➏ Flex Digital I/O Module — Uses D-Shell Base 1794-TB62DS… IB16XOB16P 16 Individually isolated with 240V AC LEDs and 4 terminals/input Fusible 120V AC/DC with extra terminals for outputs Extra terminals with 24V AC/DC blown fuse indicators for outputs Extra terminals with 120V AC/DC blown fuse indicators for outputs 16 Individually isolated with extra terminals for 120V AC DC outputs Individually isolated with extra terminals and 24V AC/DC blown fuse indicators for outputs 16 Individually isolated with 24V AC/DC blown fuse indicators and 4 terminals/output 16 Individually isolated 240V AC/DC with 4 terminals/output 16 Individually isolated with extra terminals and 120V AC/DC blown fuse indicators for outputs 16 Individually isolated with 120V AC/DC blown fuse indicators and 4 terminals/output 16 Individually isolated with 240V AC/DC blown fuse indicators and 4 terminals/output 16 Individually isolated with 24V AC/DC blown fuse indicators and 4 terminals/input 16 Individually isolated with 120V AC/DC 4 terminals/input 16 Individually isolated with 120V AC/DC blown fuse indicators and 4 terminals/input 16 Individually isolated with 240 VAC/DC blown fuse indicators and 4 terminals/input Relay Master (LED Indicating) ➍➎ 40-pin master with eight (8) 24V DC relays 40-pin master with sixteen (16) 24V DC relays 40-pin master with sixteen (16) 24V DC relays with fusing Relay Expander (LED Indicating) ➍➎ Expander with eight (8) 24V DC relays Expander with eight (8) 120V AC relays Fusible Expander 8-channel expander with 24V DC blown fuse indicators 8-channel expander with 120V AC blown fuse indicators Expander with sixteen (16) 24V DC relays with fusing Feed through Expander Expander with eight (8) feed-through channels 1492-IFM40DS240A-4 — — — — — — 1492-IFM40F-F-2 1492-IFM40F-F24-2 1492-IFM40F-F120-2 1492-IFM40F-FS-2 1492-IFM40F-FS24-2 1492-IFM40F-FS24-4 1492-IFM40F-FS-4 1492-IFM40F-FS120-2 1492-IFM40F-FS120-4 1492-IFM40F-FS240-4 1492-IFM40F-FS24A-4 1492-IFM40F-FSA-4 1492-IFM40F-FS120A-4 1492-IFM40F-FS240A-4 — 1492-RIFM40F-F24-2 — — — — — 1492-RIFM40F-FS120-2 1492-RIFM40F-FS120-4 — — — 1492-RIFM40F-FS120A-4 — — 1492-RTB20✪ — — — — — 1492-RTB20✪ 1492-RTB17✪ — — — 1492-RTB17✪ — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — B94 B94 — — — — — — — — — — — — 1492-XIM4024-8R 1492-XIM4024-16R 1492-XIM4024-16RF 1492-XIM24-8R 1492-XIM120-8R 1492-XIMF-F24-2 1492-XIMF-F120-2 1492-XIM24-16RF 1492-XIMF-2 — 1492-RXIM4024-16R — 1492-RXIM24-8R — — — — — — 1492-RTB14✪ — 1492-RTB12✪ — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — B94 B94 B94 ➊ — ➊ — ➋ ➊ ➊ Two or three expanders are connected to a master to provide a total of 32 outputs max (depends on PLC module). for Wiring System Module with Fixed Terminal Block Cat. replace the ✪ in the catalog number with the code for the desired terminal style. Publication 1492-TD008D-EN-P . insert the code for the desired cable length into the catalog number 005 = 0. refer to page 192. The code for screw style is N and the code for push in style is P. To order. 20) in the cat. for Wiring System Module with Removable Terminal Block Socket Assembly (order plugs separately) Cat. ➏ Order plugs separately (two plugs per catalog number).5 m.January 2009 OB32P IB16D IB32 . and the suffix A94 ➍ The voltage rating is relay control/coil voltage. insert the code for the desired cable length into the catalog number (010 = 1.5 m. 1492-TB37DS or -TB62DS) and a 20. 1.5 m. -IB8. To order. 1.5.0 m Yes 20 1794-TB37DS 1794-IB16. -OB8. 1794-TB37DS or 1794-TB62DS Flex I/O base and 20 or 40 individually colored #22 AWG conductors (flying leads) at the other end. 010 = 1. I/O Module-Ready Cables for 1794 Flex Digital I/O modules Using Flex Base 1794-TB37DS or -TB62DS Cable Cat. 5.0 m Build-to-Order Available Yes No. -IB16XOB16P 1492-CAB➊B94 Yes 40 1794-TB62DS ➊ Cables are available in standard lengths of 0. -OV16P. and 050 = 5. 1492-CAB➊G94 1492-CAB➊H94 ➊ Standard Build-to-Order No. No.0 m. 2. insert the code for the desired cable length into the catalog number (005 = 0.or 62-pin D-shell connector on one end to mate with the Cat. No.0 m. Pre-Wired Cables for Bulletin 1794 Flex Digital I/O Modules Using Flex Base 1794-TB37DS or -TB62DS Cable Cat. You must first select the IFM/XIM from one of the preceding selection tables.5.0 m). – OB8EP.0 m cable. No. 025 = 2.5 m.0 m cable that could be used to connect a Catalog Number 1492-IFM40F IFM to a Catalog Number 1794-IB16 I/O module.0 m. of Conductors 20 Uses Flex Base 1794-TB37DS Mating 1794 I/O Modules Catalog Number 1794-IB16.-OW8. -OV16. 2. and 5. 5.5. -IB10XOB8 1.0 m. 5.0 m 0.5.or 40–pin AMP connector at the other end to mate with the IFM/XIM module. To order.or 62-pin D-shell connector on one end to mate with the Flex base (Cat. -IB32.0.0 m. 2. -OB16.0 m).-OW8. -OB32P. 5.0 m. -OB8EP. Publication 1492-TD008D-EN-P . -OB16P.0 m Yes 40 1794-TB62DS 1794-IB16D.5. 2. The I/O module-ready cables have a 37. 2. 1. 025 = 2. -OB16P. -OB32P. and 050 = 5. These cables provide the convenience of pre-wired connectors at the I/O module end.January 2009 . -IV16. -IB16XOB16P Cables are available in standard lengths of 1. -IB32.Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems 57 Bulletin 1794 Pre-wired Cables These pre-wired cables have a 37. 1492-CAB➊A94 Standard Cable Lengths 0. OB8. No.0. of Uses Flex Mating 1794 Cable Lengths Available Conductors Base I/O Modules Catalog Number 1.0. -IB8. while allowing the flexibility to field-wire to standard terminal blocks of your choice.0. Example: Catalog Number 1492-CAB050A94 is for a 5.5.5 m. -OB16. -OV16P. -IB10XOB8 1794-IB16D. and 5. -IV16. -OV16.5 m. 2.5 m. Example: Catalog Number 1492-CAB050G94 is for a 5. 1. and 050 = 5. 1. Plugs are available in screw style and push in style terminal types. and the suffix Z94.or 25-pin D-shell terminal AIFM. Example: Catalog Number 1492-ACAB010Z94 is for a 1.5 m (010 = 1. 2. No. Note: Footnotes are on the following page. and insert the letter in the box. 3 terminals/channel 16-channel input with 24V DC blown fuse indicators. You must first select the AIFM from the preceding selection table Pre-Wired Cables for 1794 Flex Analog I/O modules Using Flex Base 1794-TB37DS or -TB62DS Cable Cat. of Uses Flex Mating 1794 Lengths Available Conductors Base I/O Modules Catalog Number 0.0 m cable. 1492-ACAB➊Z94 Standard Cable Build-to-Order No. To order. The code for screw style is N and the code for push in style is P.0 m.5 m. 010 = 1. -IF2XOF2I ➊ Cables are available in standard lengths of 0. and the suffix Z94.0 m.0 m Yes 20 1794-TB37DS 1794-IE8. No. Publication 1492-TD008D-EN-P . no. 3 terminals/output 8-channel input with 24V DC blown fuse indicators. 5 terminals/input 2-channel with 24V DC blown fuse indicators.4 terminals/channel 8-channel differential 16-channel single-ended with 3 terminals/channel Thermocouple 6-channel with 3 terminals/channel ➋ Fusible 4-channel with 24V DC blown fuse indicators. 2. 5 terminals/channel 16-channel input with 24V DC blown fuse indicators. To order. 20) in the cat. -IE4XOE2. output or 2 in/2 out combination with 3 terminal/channel 6-channel isolated with 3.5 m.0 m. Analog. 5 terminals/input.5 m 1. Example: Catalog Number 1492-ACAB050Z94 is for a 5. for Wiring System Module with Fixed Terminal Block IE4X0E2 Cat. and 5. for Wiring System Module with Removable Terminal Block Socket Assembly (order plugs separately Cat.0 m. 5. ➌ Order plugs separately (two plugs per catalog number).. No. and Specialty IFMs for Bulletin 1794 Analog I/O Modules Description of AIFM IF2X0F2I Cat.5 m. ➋ Cannot be used with 1794 I/0.58 Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems Pre-Wired Cable.e.5 m. -IF4I.0. and 050 = 5. To order. test points. 5 terminals/channel 4-input/4-output channel with 8 fuses and 24V blown fuse indicators 1492-AIFM4-3 1492-AIFM6S-3 1492-AIFM8-3 1492-RAIFM4-3 1492-RAIFM6S-3 1492-RAIFM8-3 1492-RTB8✪ 1492-RTB12✪ 1492-RTB16✪ — — Z94 — — Z94 — — Z94 Z94 1492-AIFM6TC-3 1492-AIFM4I-F-5 1492-AIFM4C-F-5 1492-AIFM8-F-5 1492-AIFM16-F-3 1492-AIFM16-F-5 1492-AIFMMQS — — — — — — — — — — — — — — — — — Z94 — — — — — — Z94 — — — — — — Z94 — — — ➊ Cables are available in standard lengths of 0. No. for Compatible Screw Style (N) and Pushin Style (P) RTB Plug ➌ I/O Module Catalog Number 1794-… ➊ 0F4I — — Z94 — — — — — — — IF4I — — Z94 — — — Z94 — — — Feed-through 4-channel input. 2.0 m cable. indicates the number of connections/pole. 025 = 2. 025 = 2. -OE4. These pre-wired cables have a wiring arm on one end to connect to the front of a Bulletin 1794 analog I/O module and a connector on the other end to plug into a 15. replace the ✪ in the catalog number with the code for the desired terminal style. insert the code for the desired cable length into the catalog number (005 = 0..5 m. test points.0 m.0 m. insert the code for the desired cable length into the catalog number 005 = 0.5 m.5.January 2009 0E4 — — — — — — — — — IE8 .0 m).0 m). and 5. The number (i.5. FF F. Configure the cable catalog number using 1492-CABLE➊ (for digital cables) or 1492-ACABLE➊ (for analog cables).FF — F. for Wiring Cat.FF F. Follow the column down to determine which Wiring System Modules are compatible with the I/O module as indicated by letter code.FF F.FF F F.FF F. Find the appropriate table based on the catalog number of the 1771 I/O module. Narrow standard 132V AC/DC Max.FF F. 3.FF — F.January 2009 OMD — F — — — — F — — OGD IMD IND IAD IBD IGD ICD IA2 IN IA IB IH IT F F.FF — — — F F F — 1492-IFM20D24 1492-IFM20D24N 1492-IFM20D120➍ 1492-IFM20D120N 1492-IFM20D24-2 1492-IFM20D24A-2 1492-IFM20D120-2 1492-IFM20D120A-2 1492-IFM20D24-3 1492-IFM20DS24-4 1492-IFM20DS120-4 1492-IFM20D240-2 1492-IFM20D240A-2 1492-IFM20F-F-2 1492-IFM20F-F24-2 1492-IFM20F-F120-2 1492-IFM20F-F240-2 1492-IFM20F-F24A-2 1492-IFM20F-F120A-2 — — — — — — — — — — — — — 1492-RIFM20F-F-2➐ 1492-RIFM20F-F24-2➐ 1492-RIFM20F-F120-2➐ — 1492-RIFM20F-F24A-2➐ 1492-RIFM20F-F120A-2➐ — — — — — — — — — — — — — — — — — — — — — — F F — — — F — — — — — — — — — — — — F F — — — F — — F — F F — — — F — — F — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — F F — — — F — — — — — — — — — — — — — — F. 5.FF — F.FF — — — — — — — — — — .FF F.FF — — — — — F. Extra terminals (2 per I/O) 264V AC/DC Max. Select the desired Wiring System Module.FF — — F.FF F. If there is no letter code.FF — F. the Wiring System Module is not compatible with the I/O module. NOTE: The letter codes designate the compatible 1492 cable for that 1771 I/O and Wiring System Module combination. No.FF — — F. for Wiring System Module with System Module with Fixed Terminal Block Removable Terminal Block Socket Assembly (order plugs separately 1492-IFM20F 1492-IFM20FN 1492-IFM20F-2 1492-IFM20F-3 1492-RIFM20F➐ 1492-RIFM20FN➑ 1492-RIFM20F-2➐ — I/O Module Catalog Number 1771-… OND➊ — — — F F — — — — OAD➊ OBD➊ Feed-through Standard 264V AC/DC Max.FF — — — F. 4. See footnote ➊ on pages 62 and 64.FF — — — — — — — — — — F F F — — — — — — F F — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — F — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — F F F — — — — F — — — — — — — — — — Publication 1492-TD008D-EN-P . No. LED Indicating Standard with 24V AC/DC LEDs Narrow standard with 24V AC/DC LEDs Standard with 120V AC/DC LEDs Narrow standard with 120V AC LEDs 24V AC/DC LEDs and extra terminals for outputs 24V AC/DC LEDs and extra terminals for inputs 120V AC LEDs and extra terminals for outputs 120V AC LEDs and extra terminals for inputs 3-wire sensor with 24V AC/DC LEDs 8 Individually isolated with 24/48V AC/DC LEDs and 4 terminals/output 8 Individually isolated with 120V AC LEDs and 4 terminals/output 240V AC LEDs and extra terminals for outputs 240V AC LEDs and extra terminals for inputs Fusible 120V AC/DC with extra terminals for outputs Extra terminals with 24V AC/DC blown fuse LED indicators Extra terminals with 120V AC/DC blown fuse LED indicators Extra terminals with 240V AC/DC blown fuse LED indicators Extra terminals with 24V AC/DC blown fuse LED indicators Extra terminals with 120V AC/DC blown fuse LED indicators — — — — — — — — F F F F — — — — F F F F F F F F F F F F F — F — — — — — — — — — F F F F — F. Find the column in the selected table for the 1771 I/O module. 3-wire sensor type input devices 132V AC/DC Max. Bulletin 1771 PLC-5 IFMs and Cables IFMs for Bulletin 1771 Digital 8-Point and 16-Point I/O Modules Description of 20-PIN IFM Cat.FF — F. 2.Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems 59 Using Bulletin 1771 Selection Tables to Make Valid 1492 Wiring System Module Catalog Numbers Follow these steps when using the selection tables to make valid catalog numbers: 1. 5 m 1.FF — F. No.5 m (010 = 1.FF — — — F. ➐ Compatible Removable Terminal Block (RTB) plug.FF — — F.0 m. No. Example: Catalog Number 1492-CABLE050A is for a 5.5 mA. For Relay Contact Ratings. 1492-RTB10N (screw style terminals) or 1492-RTB10P. 2.0 m.January 2009 OWN OD16 OQ16 OAN OBN OVN ODD ID16 IQ16 IAN IBN IVN OMD — — — — — — — — — — — — — — — — — — OGD IMD IND IAD IBD IGD ICD IA2 IN IA IB IH IT .60 Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems IFMs for Bulletin 1771 Digital 8-Point and 16-Point I/O Modules (Continued) Description of 20-PIN IFM Cat.5 m. ➎ The voltage rating is relay control/coil voltage.F — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 1492-XIM24-8R 1492-XIM120-8R 1492-XIMF-F24-2 1492-XIMF-F120-2 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — ➋ — ➋ ➋ — ➋ — — — — — 1492-XIMF-2 — — — — — — — — — — — — — ➊ Either F or FF. Extra terminals (2 per I/O) 132V AC/DC Max. and 5. insert the code for the desired cable length into the catalog number 005 = 0.F F. 025 = 2.0 m cable.FF — — F. ➋ ➋ — Bulletin 1771 PLC-5 IFMs and Cables. refer to page 192. Publication 1492-TD008D-EN-P . and 120V AC/DC blown fuse LED indicators 8 Individually isolated with four terminals/output and 120V AC/DC blown fuse LED indicators Two 4-point isolated groups with four terminals/input and 120V AC/DC blown fuse indicators 8 Individually isolated with 4 terminals/output and 240V AC/DC blown fuse indicators Relay Master (LED Indicating) ➎➏ 20-pin master with eight (8) 24V DC relays 20-pin master with eight (8) 120V AC relays 20-pin master with sixteen (16) 120V AC relays 20-pin master with sixteen (16) 120V AC relays with fusing 20-pin master relay with sixteen (16) 24V DC relays 20-pin master with sixteen (16) 24V DC relays with fusing Relay Expander (LED Indicating) ➎➏ Expander with eight (8) 24V DC relays Expander with eight (8) 120V AC relays Fusible Expander 8-channel expander with 24V DC blown fuse indicators 8-channel expander with 120V AC blown fuse indicators Feed-through Expander Expander with eight (8) feed-through channels — — — — — — — — — — — — — — — — — — — — — — — — — — — T — — — — T T — T — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — T T — — — — — — — — — — — — — — — — — — — — — — 1492-XIM2024-8R 1492-XIM20120-8R 1492-XIM20120-16R 1492-XIM20120-16RF 1492-XIM2024-16R 1492-XIM2024-16RF — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — F. ORDER PLUGS SEPARATELY. ➌ Cables are available in standard lengths of 0. 1492-IFM40F 1492-IFM40F-2 1492-RIFM40F➑ 1492-RIFM40F-2➑ J J J J M — M — K K L L L L M — M — M — L L R R L L Note: Footnotes are on the following page.5 m. for Wiring System Module with System Module with Fixed Terminal Block Removable Terminal Block Socket Assembly (order plugs separately 1492-IFM20F-FS-2 — 1492-IFM20F-FS24-2 1492-IFM20F-FS24A-4 1492-IFM20F-FS120-2 1492-IFM20F-FS120-4 1492-IFM20F-FS120A-4 1492-IFM20F-FS240-4 — — — — — — I/O Module Catalog Number 1771-… OND➊ — — — — — — — — — — — — — — — — — — — scOM16➍ M OAD➊ OBD➊ 8 Individually isolated 120V AC/DC with extra terminals for outputs 8 Individually isolated with extra terminals and 24V AC/DC blown fuse LED indicators Two 4-point isolated groups with four terminals/input and 24V AC/DC blown fuse LED indicators 8 Individually isolated with extra terminals output. An extender cable is included with each expander to connect it to the master. and insert the letter in the box. No. ➍ This IFM is not recommended for use with PLC I/O modules that have an off-state leakage current exceeding 0. To order. ➏ The LED indicates the PLC output status. ➑ Compatible Removable Terminal Block (RTB) plug. and 050 = 5.0 m.0 m). for Wiring System Module with Removable Terminal Block Socket Assembly (order plugs separately I/O Module Catalog Number 1771-… OWNA L L OW16 Feed-through Standard 132V AC/DC Max. No. for Wiring Cat. 1492-RTB20N (screw style terminals) or 1492-RTB20P. and the letter A. ➋ One expander is connected to a master to provide a total of 16 outputs. for Wiring System Module with Fixed Terminal Block Cat. ORDER PLUGS SEPARATELY. Continued IFMs for Bulletin 1771 Digital 16-Point Isolated and 32-Point I/O Modules ➌ Description of 40-PIN IFM scIM16➍ — — Cat. Use 1492-IFM20D120-2 for outputs. Use a 1492-IFM20D120N or 1492-IFM20D120A-2 for inputs. for Wiring System Module with Fixed Terminal Block Cat.Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems 61 IFMs for Bulletin 1771 Digital 16-Point Isolated and 32-Point I/O Modules (Continued)➌ Description of 40-PIN IFM scOM16➍ — — — — — — — — — M — — — — — M — — — — — — — M M M — — — — — — — — — — scIM16➍ — — — — — — — — — — — M — — — — — — — — — — — — — — — Cat. No.January 2009 OWN L L L L L OD16 OQ16 OAN OBN OVN ODD ID16 IQ16 IAN IBN IVN . No. LED Indicating Standard with 24V AC/DC LEDs 24V AC/DC LEDs and extra terminals for outputs 24V AC/DC LEDs and extra terminals for inputs 120V AC LEDs and extra terminals for outputs 120V AC LEDs and extra terminals for inputs 3-wire sensor with 24V AC/DC LEDs 16 Individually isolated with 24/48V AC/DC LEDs and 4 terminals/output 16 Individually isolated with 24V AC/DC LEDs and 4 terminals/input 16 Individually isolated with 120V AC LEDs and 4 terminals/output 16 Individually isolated with 120V AC LEDs and 4 terminals/input 16 Individually isolated with 240V AC LEDs and 4 terminals/input Fusible 120V AC/DC with extra terminals for outputs Extra terminals with 24V AC/DC blown fuse indicators for outputs Extra terminals with 120V AC/DC blown fuse indicators for outputs 16 Individually isolated with extra terminals for 120V AC DC outputs Individually isolated with extra terminals and 24V AC/DC blown fuse indicators for outputs 16 Individually isolated with 24V AC/DC blown fuse indicators and 4 terminals/output 16 Individually isolated 240V AC/DC with 4 terminals/output 16 Individually isolated with extra terminals and 120V AC/DC blown fuse indicators for outputs 16 Individually isolated with 120V AC/DC blown fuse indicators and 4 terminals/output 16 Individually isolated with 240V AC/DC blown fuse indicators and 4 terminals/output 16 Individually isolated with 24V AC/DC blown fuse indicators and 4 terminals/input 16 Individually isolated with 120V AC/DC 4 terminals/input 16 Individually isolated with 120V AC/DC blown fuse indicators and 4 terminals/input 16 Individually isolated with 240 VAC/DC blown fuse indicators and 4 terminals/input Relay Master (LED Indicating) ➏➐ 40-pin master with eight (8) 24V DC relays 40-pin master with sixteen (16) 24V DC relays 40-pin master with sixteen (16) 24V DC relays with fusing Relay Expander (LED Indicating) ➏➐ Expander with eight (8) 24V DC relays Expander with eight (8) 120V AC relays Fusible Expander 8-channel expander with 24V DC blown fuse indicators 1492-IFM40F-3 — J — — K — — — — — — — 1492-IFM40D24 1492-IFM40D24-2 1492-IFM40D24A-2 1492-IFM40D120-2 1492-IFM40D120A-2 1492-IFM40D24-3 1492-IFM40DS24-4 1492-IFM40DS24A-4 1492-IFM40DS120-4 1492-IFM40DS120A-4 1492-IFM40DS240A-4 1492-RIFM40D24➑ — 1492-RIFM40D24A-2➑ — — — — — — — — — — — — J — — — — — — J — J — — J — — — — — — — — — — — — — — M — — — — — — — — M — — — K — K — — K — — — — — — — — L — — — — — — — L L — — — — — — — — — — — — — — — — — M — — — — — — — — — — M — — — — — — — — M — — — — L L — — — — — — — — — — L — — — — — — — 1492-IFM40F-F-2 1492-IFM40F-F24-2 1492-IFM40F-F120-2 1492-IFM40F-FS-2 1492-IFM40F-FS24-2 1492-IFM40F-FS24-4 1492-IFM40F-FS-4 1492-IFM40F-FS120-2 — 1492-RIFM40F-F24-2➑ — — — — — 1492-RIFM40F-FS120-2➑ — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — L — L — — — — — L L — — — — — — — — — M — — — M — — — M — — — M — — — M M M M — L L — — — — — — — — — — — 1492-IFM40F-FS120-4 1492-IFM40F-FS240-4 1492-IFM40F-FS24A-4 1492-IFM40F-FSA-4 1492-IFM40F-FS120A-4 1492-IFM40F-FS240A-4 1492-RIFM40F-FS120-4➒ — — — 1492-RIFM40F-FS120A4➒ — — — — — — — — — — — — — — — — M M — — — M M — — — — — — — — — — — — — — — — — — — — M — — — — — M — — — — — — — — — — — — — — — — — — — — — — — 1492-XIM4024-8R 1492-XIM4024-16R 1492-XIM4024-16RF — 1492-RXIM4024-16R➓ — — — — — — — — — — — — — — — — — — — L L L — — — — — — — — — — — — — — — 1492-XIM24-8R 1492-XIM120-8R 1492-XIMF-F24-2 1492-RXIM24-8R✪ — — — — — — — — — — — — — — — — — — — — ➊ — ➊ — — — — — — — — — — — — — — — Publication 1492-TD008D-EN-P . for Wiring System Module with Removable Terminal Block Socket Assembly (order plugs separately — I/O Module Catalog Number 1771-… OWNA — L L — L — — — — — — — L L L — — — — — — — — — — — — — — — — — OW16 — — — — — — — — — — — — — — — R71 ➎ R71 ➎ — — R71 ➎ — — — — — — — — — — — — 3-wire sensor type input devices 60V AC/DC Max. -ODD. ➑ Compatible Removable Terminal Block (RTB) plug. 2. ➌ Cables are available in standard lengths of 0.5.5. 2. contacts connected. You must first select the IFM/XIM from one of the preceding selection tables Pre-Wired Cables for Bulletin 1771 Digital I/O Modules Cable Cat. For Relay Contact Ratings.0. -OBN.0.5 m cable. 1.5.com).or 40-terminal IFM/XIM.5.0. ➏ The voltage rating is relay control/coil voltage. contacts only connected.0. 1. ORDER PLUGS SEPARATELY.0 m. 2. 1. 5. -OBD.5. 1. and 050 = 5. 1492-RTB14N (screw style terminals) or 1492-RTB14P.0. ➋ Cable Catalog Number 1492-CAB➊R71 has only the N. 1.5. 5. of Conductors 20 20 40 40 40 40 40 40 20 Mating 1771 I/O Modules Catalog Number 1771-IAD. ➐ The LED indicates the PLC output status. ✪ Compatible Removable Terminal Block (RTB) plug. 5. -IQ16. 1. -SCIM16. only). 010 = 1. -IMD 1771-OAD. ➓ Compatible Removable Terminal Block (RTB) plug. -ICD. Example: Catalog Number 1492-CABLE025J is for a 2. -OGD. -OND.5. ORDER PLUGS SEPARATELY. -OBD. -OND 1771-IAN.O. 5. insert the code for the desired cable length into the catalog number 005 = 0.0 m 0. refer to page 192. ➋ One 1492-XIM24-16RF is to be used with one 1492-XIM4024-16R AND 1492-XIM4024-16RF master (32 PT.5 m cable that could be used to connect a Catalog Number 1492-IFM40F IFM to a Catalog Number 1771-ODD I/O module. -OWNA 1771-ID16.5.0 m. 1. 2.0 m Build-to-Order Available Yes Yes Yes Yes Yes Yes Yes Yes Yes No. -IN.5. 1492-RTB20N (screw style terminals) or 1492-RTB20P. 2. and the letter J. -IA2.5.0 m 0. and 5.spectrumcontrols.5 m. ORDER PLUGS SEPARATELY. and 050 = 5. 5. No. 5. 1. ➍ For information concerning this I/O module contact Spectrum Controls (phone: 425-641-9473 or www. -IB. No. 1492-RTB17N (screw style terminals) or 1492-RTB17P. No. for Wiring System Module with Fixed Terminal Block Cat.5 m. 2.5. 1.5 m.0 m. -OVN.0 m.0. ➎ Cable Catalog Number 1492-CAB➌ has the N. -IGD. 5. -IT ➊ Cables are available in standard lengths of 0. 025 = 2.0 m. 1492-RTB12N (screw style terminals) or 1492-RTB12P.5. ORDER PLUGS SEPARATELY. for Wiring System Module with Removable Terminal Block Socket Assembly (order plugs separately — — I/O Module Catalog Number 1771-… OWNA — — — OW16 — — — 8-channel expander with 120V AC blown fuse indicators Expander with sixteen (16) 24V DC relays with fusing Feed through Expander Expander with eight (8) feed-through channels 1492-XIMF-F120-2 1492-XIM24-16RF — — — — — — — — — — — — — ➋ — — — — — — — — — — 1492-XIMF-2 — — — — — — — ➊ — — — — — ➊ Two or three expanders are connected to a master to provide a total of 32 outputs max (depends on PLC module).0 m 0. -OAD. -OD16.5. ➒ Compatible Removable Terminal Block (RTB) plug.January 2009 OWN OD16 OQ16 OAN OBN OVN ODD ID16 IQ16 IAN IBN IVN . -SCOM16 1771-OW16 1771-OW16 1771-IA. 5. 1. Publication 1492-TD008D-EN-P .0 m 0. and insert the letter in the box. 2.0. 2.5 m (010 = 1. insert the code for the desired cable length into the catalog number (005 = 0. To order. and 5. -IH. -OWN.0 m. Example: Catalog Number 1492-CABLE005M is for a 0. 025 = 2. -OMD.5 m 1.0. 2.5. -OQ16. -IND. -IBD.5. 5. 2. 1492-CABLE➊F 1492-CABLE➊FF 1492-CABLE➊J 1492-CABLE➊K 1492-CABLE➊L 1492-CABLE➊M 1492-CABLE➊R 1492-CAB➊R71➋ 1492-CABLE➊T Standard Cable Lengths 0.0 m 0.0 m 0.5.0 m).5.0.5 m. Bulletin 1771 PLC-5 IFMs and Cables.0 m 0. Continued These pre-wired cables have a wiring arm on one end to connect to the front of a Bulletin 1771 digital I/O module and a connector on the other end to plug into a 20.5 m. Note: Footnotes are on the following page.O.5. To order.0 m 0. -IBN 1771-IVN 1771-OAN.0 m). 2.62 Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems IFMs for Bulletin 1771 Digital 16-Point Isolated and 32-Point I/O Modules (Continued)➌ Description of 40-PIN IFM scOM16➍ — — — scIM16➍ — — — Cat.5 m. An extender cable is included with each expander to connect it to the master. 2. 2-channel/output with 24V DC blown fuse indicators.0. 2. -ID01. while still allowing the flexibility to field-wire to standard terminal blocks of your choice. -OQ16.0 m). -OBD ➍. -OMD.5. 2. -OA. -IH.0 m Yes 40 1771-IAN. -IGD.0.0 m cable with a pre-wired Catalog Number 1771-WN wiring arm on one end.5. -OD. -IVN. ➍ Includes an optional 3 A fuse in the Wiring Arm for 1771 PLC mating I/O Modules. -ON. -ODD.0 m. 2. -OR. ➎ Standard Build-to-Order No. test points.5. -OMD ➍. insert the code for the desired cable length into the catalog number (010 = 1. and 050 = 5. -OM.0 m Yes 20 1771-IAD. -OW16. Example: Catalog Number 1492-CABLE050WN is for a 5.5 m.0. No.0 m Yes 12 1771-IA. 2. -ID16.0 m. -OW. -IV. -OND ➍ 1492-CABLE➌WN 1. -OBD. 5. -IND. of Mating 1771 Cable Lengths Available Conductors I/O Modules Catalog Number 1492-CABLE➌WA 1. -IT. -IBD. -OWN. -OBN.January 2009 OFE3 G IR IL .5 m. -IA2. Bulletin 1771 PLC-5 AIFMs and Cables IFMs for Bulletin 1771 Analog I/O Modules Description of AIFM IFE (Single-Ended) IFF (Single-Ended) Catalog Number for Wiring System Module with Fixed Terminal Block Catalog Number for Wiring System Module with Removable Terminal Block Socket Assembly (order plugs separately I/O Module Catalog Number 1771-… IFE (Differential) IFF (Differential) OFE1 OFE2 G — — — — — — Feed-through 4-channel input. -OAN. 5 terminals/channel 1492-AIFM4-3 1492-AIFM6S-3 1492-AIFM8-3 1492-RAIFM4-3➌ 1492-RAIFM6S-3➍ 1492-RAIFM8-3➎ — — E — — F — — E — — F — — H — J — G — — — — 1492-AIFM6TC-3 1492-AIFM4I-F-5 1492-AIFM4C-F-5 — — — — — — — — — — — — — — — — — — — — — — — — — — — 1492-AIFM8-F-5 — E — E — — — — — Publication 1492-TD008D-EN-P . 5. -OZL 1492-CABLE➌WH 1. 5. 3 terminals/ output 8-channel Input with 24V DC blown fuse indicators. ➎ Discrete I/O ready cables should not be used with PLC analog I/O modules as a cable shield and drain wires are not provided. 025 = 2. output or 2 in/2 out combination with 3 terminals/channel 6-channel isolated with 3…4 terminals/channel 8-channel differential 16-channel single-ended with 3 terminals/channel Thermocouple 6-channel with 3 terminals/channel➋ Fusible 4-channel with 24V DC blown fuse indicators. -IM. -IBN. -IC. -OAD ➍. -ICD. 5 terminals/input. 5. -OND 1492-CABLE➌WHF 1.0 m Yes 20 1771-IBD ➍. -IMD.0. 5. -IN. -ODZ.0 m. 2. 5 terminals/input 2-channel/input. test points. -OC. -OVN.5. -IQ16.5. -OYL. -OWNA ➌ Cables are available in standard lengths of 1.0 m Yes 12 1771-ID. -OD16.Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems 63 The I/O module-ready cables have a wiring arm on one end to plug onto the front of a Bulletin 1771 I/O module and 20 or 40 individually colored #18 AWG conductors on the other end. -OAD. -OP 1492-CABLE➌WD 1. These cables provide the convenience of pre-wired connections at the I/O module end.0. -IB. I/O Module-Ready Cables for 1771 Digital I/O Modules Cable Cat. and 5. -OB. To order. -OGD. 5. and insert the letter in the box.0. Example: Catalog Number 1492-ACABLE025H is for a 2. 010 = 1. 025 = 2. 2.5 m cable. Pre-Wired Cables for Bulletin 1771 Analog I/O Modules Cable Catalog Number 1492-ACABLE➊E 1492-ACABLE➊F 1492-ACABLE➊G 1492-ACABLE➊H 1492-ACABLE➊J Standard Cable Lengths 0.5 m.0 m 0. 3 terminals/channel 16-channel Input with 24V DC blown fuse indicators. 2.5.5 m. 5.0 m.5.5.5 m.0 m.5 m.5. and the letter H. To order. 1.0 m 0. 5.5 m (010 = 1. 2.5 m. 5.0.64 Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems IFMs for Bulletin 1771 Analog I/O Modules (Continued) Description of AIFM IFE (Single-Ended) IFF (Single-Ended) Catalog Number for Wiring System Module with Fixed Terminal Block Catalog Number for Wiring System Module with Removable Terminal Block Socket Assembly (order plugs separately — — — I/O Module Catalog Number 1771-… IFE (Differential) IFF (Differential) OFE1 OFE2 — — — 16-channel Input with 24V DC blown fuse indicators. ➍ Compatible Removable Terminal Block (RTB) plug.or 25-pin D-shell terminal AIFM. 2.0. 2. and 050 = 5.5. You must first select the AIFM from the preceding selection table . 025 = 2. 1. -IFF Differential 1771-IFE.0 m). 1492-RTB8N (screw style terminals) or 1492-RTB8P. These pre-wired cables have a wiring arm on one end to connect to the front of a Bulletin 1771 analog I/O module and a connector on the other end to plug into a 15. ➎ Compatible Removable Terminal Block (RTB) plug. To order. insert the code for the desired cable length into the catalog number (005 = 0.0 m. 1492-RTB16N (screw style terminals) or 1492-RTB16P. 5 terminals/channel 4-input /4-output channel with 8 fuses and 24V blown fuse indicators 1492-AIFM16-F-3 1492-AIFM16-F-5 1492-AIFMQS — — — F F — — — — F F — — — — — — — — — — — — — ➊ Cables are available in standard lengths of 0. ➋ Cannot be used with 1771 I/O.5.5. and 5.0. 1.0 m 0. 1. and 5. Build-to-order lengths are also available. insert the code for the desired cable length into the catalog number 005 = 0.0 m).0 m. 1492-RTB12N (screw style terminals) or 1492-RTB12P.0 m.5.0 m 0. -IFF Single-Ended 1771-OFE1. and 050 = 5. 2.5 m. -OFE2.0 m Build-to-Order Available Yes Yes Yes Yes Yes AIFM Connector 25-pin D-shell 25-pin D-shell 15-pin D-shell 25-pin D-shell 25-pin D-shell Mating 1771 I/O Modules 1771-IFE. 1. ORDER PLUGS SEPARATELY.5 m cable that could be used to connect a Catalog Number 1492-AIFM8-3 IFM to a Catalog Number 1771-IFE I/O module. ➌ Compatible Removable Terminal Block (RTB) plug.January 2009 OFE3 IR IL . 1. Publication 1492-TD008D-EN-P . Example: Catalog Number 1492-ACABLE005E is for a 0. -OFE3 1771-IL 1771-IR ➊ Cables are available in standard lengths of 0.0.0 m.5. ORDER PLUGS SEPARATELY. ORDER PLUGS SEPARATELY. 2.5 m. 1. 5.5. January 2009 .0 m 1. 2. respectively). Consult your distributor for availability. IFM-Ready I/O Cable Cable Catalog Number 1492-CABLE➊P 1492-CABLE➊Q Standard Cable Lengths 1.) 11.5 m.0 m cable) All Bulletin 1492 cables are available in build-to-order lengths.Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems 65 Selection Tables.5 m 1.36 in. 20 conductor IFM-ready cable. 2. 2. These cables allow the IFM to be used in specialty applications that require a custom connection.0 m. 5. Continued IFM-Ready I/O Cables IFM-ready cables have a cable connector on one end to attach to the IFM and either 20 or 40 individually colored conductors on the other end (CABLE➊P and CABLE➊Q.0…99.1…2.5.7 mm (0. Build-to-Order Length Cables Build-to-Order Length Cables Cable Lengths 0.5 m cable) 1492-CABLE150RTBB (15.0 m Increment Size 0. insert the desired cable length into the catalog number (010 = 1.5 m.0. 5. Also refer to Build-to-Order Length Cables on page 65.0 m 10.0 m. Publication 1492-TD008D-EN-P . 025 = 2.0…10. and 5.0 m Cable Length Codes 001…020 020…100 100…990 Example Catalog Number 1492-CABLE015A (1. To order. 80°C 300V.0. and 050 = 5. 80°C No.0 m 2.0 m Insulation Rating 300V.1 m 0.46 in.5.0 m). 1492-XIM20… 1492-IFM40….5 m. 1492-XIM40… ➊ Cables are available in lengths of 1. Example: Catalog Number 1492-CABLE025P is for a 2.) Current/ Compatible Conductor IFM Catalog Numbers 2A 2A 1492-IFM20…. Conductors 20 40 Conductor Nominal Outer Size Diameter 22 AWG 22 AWG 9 mm (0.5 m cable) 1492-CABLE075P (7.0 m. 4.January 2009 TB2 A7S A7S A7S . Find the appropriate table based on the PowerFlex 700H or 700 S control I/O module. 5. Extra terminals (2 per I/O) 264V AC/DC Max. ORDER PLUGS SEPARATELY. 1492-RTB10N (screwstyle terminals) or 1492-RTB10P. If there is no letter code. 1492-IFM20F 1492-IFM20FN 1492-IFM20F-2 1492-RIFM20F➊ 1492-RIFM20FN➋ 1492-RIFM20F-2➊ A7H A7H A7H ➊ Compatible Removable Terminal Block (RTB plug. 2. 1492-RTB20N (screwstyle terminals) or 1492-RTB20P. ➋ Compatible Removable Terminal Block (RTB plug. Continued Using PowerFlex 700H & 700S Drive Selection Tables to Make Valid 1492 Wiring System Module Catalog Numbers Follow these steps when using the selection tables to make valid catalog numbers: 1. Configure the cable catalog number using 1492-CAB➊ (for digital cables) or 1492-ACAB➊ (for analog cables). Select the desired Wiring System Module.66 Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems Selection Tables. Follow the column down to determine which Wiring System Modules are compatible with the I/O module as indicated by letter code. Find the column in the selected table for the I/O module. There is a second connector on the other end to plug into a 20-pin IFM. NOTE: The letter codes designate the compatible 1492 cable for that PowerFlex 700H or 700S control I/O and Wiring System Module combination. 3. PowerFlex 700H and 700S Drive IFMs. You must first select the IFM from the table below. Narrow standard 132V AC/DC Max. ORDER PLUGS SEPARATELY. See footnote ➊ on pages 50 and 53. AIFMs and Cables PowerFlex 700H and 700S drive Digital Control I/O Description of 20-PIN IFM Catalog Number for Wiring System Module with Fixed Terminal Block Catalog Number for Wiring System Module with Removable Terminal Block Socket Assembly (order plugs separately) 700H Drive I/O Module 20C-DO1 & 20CDA1-A 20C-DO1 & 20CDA1-B B7H B7H B7H 700S Drive I/O Module Feed-through Standard 264V AC/DC Max. These pre-wired cables have a pre-wired removable terminal block (RTB) on one end to connect to the PowerFlex 700H or PowerFlex 700S drive digital control I/O board terminal. the Wiring System Module is not compatible with the I/O module. Publication 1492-TD008D-EN-P . and 050 = 5. 2.5. insert the code for the desired cable length into the catalog number (005 = 0. 1. ORDER PLUGS SEPARATELY. 5.5.0. 1.5.Digital/Analog Programmable Controller and PowerFlex® Drive Wiring Systems 67 Pre-Wired cables for PowerFlex 700H and 700S Drive Digital I/O Cable Catalog Number 1492-CAB➊A7H 1492-CAB➊B7H 1492-CAB➊A7S Standard Cable Length 0.5 m. 5.5 m cable that could be used to connect a Catalog Number 1492-AIFM6S-3 analog IFM to a PowerFlex 700S drive analog terminal I/O. 2.These pre-wired cables have a prewired removable terminal block (RTB) on one end to connect to the PowerFlex 700H or PowerFlex 700S drive analog control I/O board terminal.5.5. 1. 1.5. 2.5 m. 2. and 050 = 5. 025 = 2. and 5. To order. No or Terminal 20C-DA1-A and 20C-DO1 20C-DA1-B and 20C-DO1 Terminal TB2 ➊ Cables are available in standard lengths of 0. 5. insert the code for the desired cable length into the catalog number (005 = 0.0 m Build-to-Order Available Yes Yes Yes Number of Conductors 25-Pin D-Shell 25-Pin D-Shell 25-Pin D-Shell Mating PowerFlex Control Board Cat. 1. Example: Catalog Number 1492-CAB005A7H is for a 0.5 m cable that could be used to connect a Catalog Number 1492-IFM20F IFM to a PowerFlex 700H drive 20C-DO1 and 20C-DA1-A module. To order.0.January 2009 TB1 (Pins 13…24) TB1 (Pins 1…12) .0 m).5 m.0. Pre-Wired Cables for PowerFlex 700H and 700S Drive Analog I/O Cable Catalog Number 1492-ACAB➊Z7H 1492-ACAB➊Z7S 1492ACAB➊Z7S Standard Cable Length 0. 2. Example: Catalog Number 1492-ACAB005Z7S is for a 0. 010 = 1.5. 1.5.5 m.0 m. No or Terminal 20C-DA1-A or 20C-DA1-B I/O board Terminal TB1 (DINS 1…12) Terminal TB2 (DINS 13…24) ➊ Cables are available in standard lengths of 0.5 m. 5. 1492-RTB12N (screw style terminals) or 1492-RTB12P (pushin style terminals.5. 010 = 1.0 m). and 5.0 m.0 m. 2. available August 2007).0 m 0. PowerFlex 700H and 700S Drive Analog Control I/O Description of Analog IFM Catalog Number for Wiring System Module with Fixed Terminal Block Catalog Number for Wiring System Module with Removable Terminal Block Socket Assembly (order plugs separately) 700H Drive I/O Module 20C-DA1-A or 20C-DA1-B 700S Drive I/O Module Feed-through 6-channel isolated with 3…4 terminals/channel 2-channel counter inputs with 4 output points 2-channel fused counter inputs with 4 fused output points 1492-AIFM6S-3 1492-AIFMCE4 1492-AIFMCE4-F 1492-RIFM6S-3➊ — — Z7H — — Z7S — — X7S X7S ➊ Compatible Removable Terminal Block (RTB) plug. 5.0.0 m. There is a 25-pin D-shell connector on the other end to plug into the mating AIFM module terminal.5 m.5.0. Publication 1492-TD008D-EN-P .5 m. 1.0 m 0.5.5 m.5. 5. 1.0 m Build-to-Order Available Yes Yes Yes Number of Conductors 20 20 20 Mating PowerFlex Control Board Cat. 025 = 2. 2.0 m.0.0 m 0. 2.0 m.0 m 0. You must first select the AIFM from the table below. -RIFM20F 1492-IFM20F-2. RIFM40F-2 1492-IFM40F-F-2 1492-IFM40F-FS-2 1492-IFM40F-FSA-4 1492-IFM40F-FS-4 1492-IFM40F-3 1492-IFM40DS24-4 1492-IFM40D24. refer to page 180. -RIFM20F-F24-2 1492-IFM20F-F24A-2. -RXIM24-8R 1492-XIM24-16RF 1492-XIMF-F24-2 1492-XIM20120-16R 1492-XIM20120-16RF 1492-XIM20120-8R 1492-XIM120-8R 1492-XIMF-F120-2 1492-XIMF-2 — — Page No. for Specifications 186 187 187 187 187 186 187 188 188 188 188 188 188 188 188 188 188 188 188 188 188 188 — — For all IFM dimensions.January 2009 .68 Digital/Analog Programmable Controller Wiring Systems Digital IFM Specifications IFM Catalog Number 1492-IFM20F. -RIFM40F-FS120-4 1492-IFM40F-FS120A-4. for Application Notes and Pinout 100 106 110 111 114 101 112 123 126 122 115 118 119 127 131 132 120 121 117 129 134 136 — — Page No. -RIFM40F-F24-2 1492-IFM40F-FS24-2 1492-IFM40D120A-2 1492-IFM40D120-2 1492-IFM40DS120-4 Page No. For Field-Side Wiring Diagrams. Publication 1492-TD008D-EN-P . -RIFM20FN — 1492-IFM20D24N 1492-IFM20D24-2 1492-IFM20D24A-2 1492-IFM20D24-3 1492-IFM20F-F24-2. -RXIM4024-16R 1492-XIM4024-16RF 1492-XIM4024-8R 1492-XIM2024-8R 1492-XIM2024-16R 1492-XIM2024-16RF 1492-XIM24-8R. for Application Notes and Pinout 76 82 88 78 80 83 89 89 102 107 114 108 90 97 91 92 93 96 98 103 107 95 94 99 Page No. -RIFM20F-F24A-2 1492-IFM20F-FS24-2 1492-IFM20F-FS24A-4 1492-IFM20D120 1492-IFM20D120N 1492-IFM20D120-2 1492-IFM20D120A-2 1492-IFM20DS120-4 1492-IFM20F-F120-2. -RIFM20F-2 1492-IFM20F-3 1492-IFM20FN. Refer to the online documentation for new product information. -RIFM40F 1492-IFM40F-2. -RIFM20F-F120-2 1492-IFM20F-F120A-2. -RIFM20F-F120A-2 1492-IFM20F-FS120-2. 1492-IFM20F-FS120-4 1492-IFM20F-FS120A-4 1492-IFM20D240-2 Page No. for IFM Specifications Catalog Number 187 187 187 187 — 187 187 187 187 187 187 187 187 187 187 187 187 187 187 187 187 187 187 187 1492-IFM20D240A-2 1492-IFM20F-F240-2 1492-IFM20F-FS240-4 1492-IFM20DS24-4 1492-IFM20F-F-2. for IFM Specifications Catalog Number 188 188 188 188 188 188 188 188 188 188 188 189 189 189 189 189 189 189 189 189 189 189 189 189 1492-IFM40DS120A-4 1492-IFM40F-F120-2 1492-IFM40F-FS120-2. -RIFM40D24 1492-IFM40D24-2 1492-IFM40D24A-2. refer to page 181. -RIFM40F-FS120-2 1492-IFM40F-FS120-4. refer to the Wiring System web page at http://www. For general Adhesive Label Card information.com/catalogs/RAISE. -RIFM20F-F-2 1492-IFM20F-FS-2 1492-IFM40F. Refer to page 186 for specific platform web site information. for Application Notes and Pinout 70 71 71 70 — 72 74 74 77 80 81 83 84 73 73 75 75 79 81 82 85 86 87 76 Digital/Analog Programmable Controller Wiring Systems Page No. -RIFM40D24A-2 1492-IFM40D24-3 1492-IFM40DS24A-4 1492-IFM40F-F24-2.ab. -RIFM40F-FS120A-4 1492-IFM40DS240A-4 1492-IFM40F-FS240-4 1492-XIM4024-16R. C./N.January 2009 . Relay Contact ~ ~ Relay Coil Circuit Publication 1492-TD008D-EN-P .Digital/Analog Programmable Controller Wiring Systems 69 Symbols and Terminal Identification Conventions Used Throughout the Pinout Section Fuse and Blown Fuse Indicator (where applicable) LED Circuit LED Indicator Connector Pin Field-Side Terminal N.O. Compatibility — To ensure proper operation with the I/O module. refer to the Wiring System web site information on page 186.January 2009 . do not exceed the voltage and current ratings of the IFM. Application Notes 1. Pinout 1 2 3 A1 A2 A3 Pinout 2 11 B1 B2 18 19 20 A18 A19 A20 18 20 B9 B10 1 3 A1 A2 10 19 A9 A10 Publication 1492-TD008D-EN-P . 3. Wiring — Refer to the Label Section on page 181. refer to the Wiring System web site information on page 186. 2. Dimensions — Refer to page 187. Application Notes 1. Wiring — Refer to the Label Section on page 181. For Field-Side Wiring Diagrams. 1492-IFM20FN 1492-RIFM20FN Feed-Through Narrow Standard 132V AC/DC Max. Dimensions — Refer to page 187. 2. For Field-Side Wiring Diagrams. do not exceed the voltage and current ratings of the IFM.70 Digital/Analog Programmable Controller Wiring Systems 1492-IFM20F 1492-RIFM20F Feed-Through Standard 264V AC/DC Max. Compatibility — To ensure proper operation with the I/O module. 3. Dimensions — Refer to page 187. Wiring — Refer to the Label Section on page 181. Application Notes 1. Dimensions — Refer to page 187. All of the input devices used must reference the same power source. refer to the Wiring System web site information on page 186.Digital/Analog Programmable Controller Wiring Systems 71 1492-IFM20F-2 1492-RIFM20F-2 Feed-Through Extra Terminals (2 per I/O) 264V AC/DC Max. 3. 4. do not exceed the voltage and current ratings of the IFM. Wiring — Refer to the Label Section on page 181. Pinout 1 2 3 B1 B2 B3 Pinout 3 C1 18 C16 B1 B2 18 19 20 B18 B19 B20 20 B17 A1 A2 A11 A12 B18 A1 A2 A9 A10 A19 A20 A16 A17 1 A18 Publication 1492-TD008D-EN-P . For Field-Side Wiring Diagrams. Compatibility — To ensure proper operation with the I/O module. 2. For Field-Side Wiring Diagrams. 1492-IFM20F-3 Feed-Through 3-Wire Sensor Type Input Devices 132V AC/DC Max. refer to the Wiring System web site information on page 186. do not exceed the voltage and current ratings of the IFM. 2.January 2009 . Application Notes 1. 4. Isolation — The power bus is isolated into two groups of 10 terminals. 3. This allows each group of the I/O devices to reference a different power source. Compatibility — To ensure proper operation with the I/O module. Isolation — The power busses are connected to one common (one bus has 17 terminals. and one bus has 18 terminals). g. For Field-Side Wiring Diagrams. surge suppression must be used (e.. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load. Wiring — The LEDs are powered from the two-position terminal block. 2. Isolation — The LEDs are broke into two separate groups. All of the I/O devices must reference the same power source. a 1N4004 diode reverse-wired across a DC load). When this IFM is used with a hard contact (relay) output circuit that switches an inductive load. For Field-Side Wiring Diagrams.January 2009 ~ ~ ~ ~ LED Circuit L E D 8 -1 5 L E D 0 -7 ➀ . 2. Application Notes 1. Compatibility — To ensure proper operation with the I/O module. a 1N4004 diode reverse-wired across a DC load). do not exceed the voltage and current ratings of the IFM. 3. Pinout 2 11 B1 B2 Pinout 1 2 3 A1 A2 A3 18 20 B9 B10 1 3 A1 A2 18 19 20 A 18 A 19 A 20 10 19 A9 A10 Publication 1492-TD008D-EN-P . Make only one connection to the power source for normal operation. Compatibility — To ensure proper operation with the I/O module. surge suppression must be used (e. 3. Wiring — Refer to the Label Section on page 181.” 4. do not exceed the voltage and current ratings of the IFM. Dimensions — Refer to page 187.72 Digital/Analog Programmable Controller Wiring Systems 1492-IFM20D24 LED Indicating Standard with 24V AC/DC LEDs 1492-IFM20D24N LED Indicating Narrow Standard with 24V AC/DC LEDs Application Notes 1. Isolation — The LEDs are connected to one common. refer to the Wiring System web site information on page 186..g. refer to the Wiring System web site information on page 186. Refer to the Label Section on page 181. Dimensions — Refer to page 187. Group 1 is commoned at terminal “Test 0-7” and Group 2 is commoned at terminal “Test 8-15. 4. 2. Compatibility — To ensure proper operation with the I/O module.. For Field-Side Wiring Diagrams. do not exceed the voltage and current ratings of the IFM.. Wiring — Refer to the Label Section on page 181. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load. 4.Digital/Analog Programmable Controller Wiring Systems 73 1492-IFM20D120 LED Indicating Standard with 120V AC/DC LEDs 1492-IFM20D120N LED Indicating Narrow Standard with 120V AC LEDs Application Notes 1. Dimensions — Refer to page 187. No. Dimensions — Refer to page 187.5 mA. do not exceed the voltage and current ratings of the IFM. 1492-IFM20D120N instead. 4.g. 1492-IFM20D120-2 for output modules.g. 3. This IFM is not recommended for use with input devices or programmable controller output circuits having an off-state leakage current exceeding 0. or use Cat. a 1N4004 diode reverse-wired across a DC load). 3. surge suppression must be used (e. Application Notes 1. No. surge suppression must be used (e. Compatibility — To ensure proper operation with the I/O module. Use Cat. Wiring — Refer to the Label Section on page 181. 1492-IFM20D120A-2 for input modules and Cat. No. All of the I/O devices must reference the same power source. a 1N4004 diode reverse-wired across a DC load). Isolation — The LEDs are connected to one common. This allows each group of the I/O devices to reference a different power source. Pinout 2 11 B1 B2 18 20 B9 B10 Pinout 1 2 3 A1 A2 A3 1 3 A1 A2 10 A10 11 A11 10 18 19 20 A18 A19 A20 A9 A10 19 LED Circuit L2 (-) L2 (-) Publication 1492-TD008D-EN-P . refer to the Wiring System web site information on page 186. For Field-Side Wiring Diagrams. refer to the Wiring System web site information on page 186. Isolation — The LEDs are isolated into two groups of eight terminals. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load. 2.January 2009 . For Field-Side Wiring Diagrams. 3.January 2009 . Pinout 1 2 3 B1 B2 B3 Pinout 1 2 3 B1 B2 B3 10 B10 11 B11 18 19 20 B18 B19 B20 18 19 20 B18 B19 B20 A1 A11 A2 A12 A1 A9 A19 A10 A20 LED Circuit A2 LED Circuit A19 A20 Publication 1492-TD008D-EN-P . Isolation — The power bus and LEDs are isolated into two groups of 10 terminals (eight LEDs). refer to the Wiring System web site information on page 186. Dimensions — Refer to page 187. The LEDs are connected to one common. surge suppression must be used (e. refer to the Wiring System web site information on page 186. Isolation — The power bus comprises 20 terminals connected together. 4.g. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load. 4. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load. do not exceed the voltage and current ratings of the IFM. Compatibility — To ensure proper operation with the I/O module. Compatibility — To ensure proper operation with the I/O module. 3. do not exceed the voltage and current ratings of the IFM. Wiring — Refer to the Label Section on page 181. This allows each group of output devices to reference a different power source. Dimensions — Refer to page 187..g.. For Field-Side Wiring Diagrams. Application Notes 1. a 1N4004 diode reverse-wired across a DC load). Wiring — Refer to the Label Section on page 181. 2. a 1N4004 diode reverse-wired across a DC load). surge suppression must be used (e. 2.74 Digital/Analog Programmable Controller Wiring Systems 1492-IFM20D24-2 LED Indicating 24V AC/DC LEDs & Extra Terminals for Outputs 1492-IFM20D24A-2 LED Indicating 24V AC/DC LEDs & Extra Terminals for Inputs Application Notes 1. All of the I/O devices must reference the same power source. g. do not exceed the voltage and current ratings of the IFM. 3.g. refer to the Wiring System web site information on page 186. do not exceed the voltage and current ratings of the IFM. For Field-Side Wiring Diagrams. an MOV wired across an AC load).Digital/Analog Programmable Controller Wiring Systems 75 1492-IFM20D120-2 LED Indicating 120V AC LEDs & Extra Terminals for Outputs 1492-IFM20D120A-2 LED Indicating 120V AC LEDs & Extra Terminals for Inputs Application Notes 1. The LEDs are connected to one common. Compatibility — To ensure proper operation with the I/O module. 2. Pinout 1 2 3 B1 B2 B3 Pinout 1 2 10 B10 B1 B2 B3 3 11 B11 18 19 20 B18 B19 B20 18 19 20 B18 B19 B20 A1 A11 A2 A12 A1 A9 A19 A10 A20 LED Circuit A2 LED Circuit A19 A20 Publication 1492-TD008D-EN-P . Isolation — The power bus and LEDs are isolated into two groups of 10 terminals (8 LEDs). refer to the Wiring System web site information on page 186. All of the I/O devices must reference the same power source. 4. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load. Wiring — Refer to the Label Section on page 181. 3.. Application Notes 1. Dimensions — Refer to page 187. Compatibility — To ensure proper operation with the I/O module. surge suppression must be used (e. For Field-Side Wiring Diagrams. Isolation — The power bus comprises 20 terminals connected together. 2. Dimensions — Refer to page 187. This allows each group of output devices to reference a different power supply. 4. surge suppression must be used (e.. an MOV wired across an AC load).January 2009 . When this IFM is used with a hard contact (relay) output circuit that switches an inductive load. Wiring — Refer to the Label Section on page 181. 76 Digital/Analog Programmable Controller Wiring Systems 1492-IFM20D240-2 LED Indicating 240V AC LEDs & Extra Terminals for Outputs 1492-IFM20D240A-2 LED Indicating 120V AC LEDs & Extra Terminals for Inputs Application Notes 1. Compatibility — To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load). 2. Wiring — Refer to the Label Section on page 181. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 186. 3. Isolation — The power bus and LEDs are isolated into two groups of 10 terminals (8 LEDs). This allows each group of output devices to reference a different power supply. 4. Dimensions — Refer to page 187. Application Notes 1. Compatibility — To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load). 2. Wiring — Refer to the Label Section on page 181. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 186. 3. Isolation — The power bus comprises 20 terminals connected together. The LEDs are connected to one common. All of the I/O devices must reference the same power source. 4. Dimensions — Refer to page 187. Pinout 1 2 3 B1 B2 B3 Pinout 1 2 3 10 11 B10 B11 B1 B2 B3 18 18 19 20 B18 B19 B20 B18 B19 B20 A1 A2 19 20 A1 A11 A12 LED Circuit A2 LED Circuit A19 A20 A9 A10 A19 A20 Publication 1492-TD008D-EN-P - January 2009 Digital/Analog Programmable Controller Wiring Systems 77 1492-IFM20D24-3 LED Indicating 3-Wire Sensor with 24V AC/DC LEDs Pinout 3 C1 18 C16 B1 B2 1 2 19 20 Application Notes 1. Compatibility — To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used. 2. Wiring — Refer to the Label Section on page 181. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 186. 3. Isolation — The LEDs are connected to one common. All of the field input devices must reference the same power source. 4. Dimensions — Refer to page 187. B17 B18 A1 A2 LED Circuit A17 A18 Publication 1492-TD008D-EN-P - January 2009 78 Digital/Analog Programmable Controller Wiring Systems 1492-IFM20DS24-4 LED Indicating 8 Individually Isolated with 24/48V AC/DC LEDs & 4 Terminals/Output Pinout 10 B1 B2 2 (even) 8 12 (even) 18 3 (odd) B10 B11 B6 B7 B3 Application Notes 1. Compatibility — To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used. 2. Wiring — Refer to the Label Section on page 181. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 186. 3. Isolation — There are eight individually isolated channels. LED returns are individually isolated. 4. Extra Terminals — Two field-side terminals are internally connected on the IFM for each channel, and are available for power source common connections. 5. Dimensions — Refer to page 187. 9 11 (odd) 17 20 B14 B15 B18 B19 B20 1 A1 A2 A3 A4 A9 A10 A11 A12 A17 A18 19 A19 A20 Publication 1492-TD008D-EN-P - January 2009 an MOV wired across an AC load). 3.January 2009 . 2.. Isolation — There are eight individually isolated channels. Compatibility — To ensure proper operation with the I/O module.Digital/Analog Programmable Controller Wiring Systems 79 1492-IFM20DS120-4 LED Indicating 8 Individually Isolated with 120V AC LEDs & 4 Terminals/Output Pinout 10 B1 B2 2 (even) 8 12 (even) 18 3 (odd) 9 11 (odd) B3 B6 B7 B10 B11 B14 B15 Application Notes 1. Dimensions — Refer to page 187.g. 5. For Field-Side Wiring Diagrams. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load. refer to the Wiring System web site information on page 186. do not exceed the voltage and current ratings of the IFM. and are available for power source common connections. Wiring — Refer to the Label Section on page 181. 17 20 B18 B19 B20 1 A1 A2 A3 A4 A9 A10 A11 A12 A17 A18 19 A19 A20 Publication 1492-TD008D-EN-P . 4. LED returns are individually isolated. Extra Terminals — Two field-side terminals are internally connected on the IFM for each channel. surge suppression must be used (e. Isolation — The power bus. This allows each group of output devices to reference a different power source. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load. This allows each group of output devices to reference a different power source. 5. Pinout 1 2 3 B1 B2 B3 Pinout 1 B1 B2 B3 18 19 20 B18 B19 B20 2 3 A1 A2 A11 A12 18 19 20 A1 A2 A11 A12 B18 B19 B20 A9 A10 A19 A20 A9 A10 A19 A20 Blown Fuse Indicator Circuit Publication 1492-TD008D-EN-P . Fuses (5 x 20 mm) are not included. 5. Compatibility — To ensure proper operation with the I/O module. Fusing — Fuse holders are included with the IFM. Wiring — Refer to the Label Section on page 181. 2. fuse clips. 4. refer to the Wiring System web site information on page 186. Isolation — The power bus and fuse clips are isolated into two groups of 10 terminals (eight fuse clips). 2. surge suppression must be used. For Field-Side Wiring Diagrams. 3. do not exceed the voltage and current ratings of the IFM. Compatibility — To ensure proper operation with the I/O module. Wiring — Refer to the Label Section on page 181. 3. Dimensions — Refer to page 187. Fusing — Fuse holders are included with the IFM. 4. refer to the Wiring System web site information on page 186. and blown fuse indicators are isolated into two groups of 10 terminals (eight fuse clips and blown fuse indicators).January 2009 . Application Notes 1. For Field-Side Wiring Diagrams. do not exceed the voltage and current ratings of the IFM. Dimensions — Refer to page 187.80 Digital/Analog Programmable Controller Wiring Systems 1492-IFM20F-F-2 1492-RIFM20F-F-2 Fusible Extra Terminals for Outputs 1492-IFM20F-F24-2 1492-RIFM20F-F24-2 Fusible Extra Terminals with 24V AC/DC Blown Fuse Indicators Application Notes 1. Fuses (5 x 20 mm) are not included. Wiring — Refer to the Label Section on page 181. 2. Compatibility — To ensure proper operation with the I/O module. and blown fuse indicators are isolated into two groups of 10 terminals (eight fuse clips and blown fuse indicators). 4. 3. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load. Isolation — The power bus. an MOV wired across an AC load). Fuses (5 x 20 mm) are not included. This allows each group of output devices to reference a different power source. Compatibility — To ensure proper operation with the I/O module. fuse clips. do not exceed the voltage and current ratings of the IFM. Fuses (5 x 20 mm) are not included. Fusing — Fuse holders are included with the IFM. Isolation — The power bus. 5. For Field-Side Wiring Diagrams. Wiring — Refer to the Label Section on page 181.g. surge suppression must be used (e. 3. Dimensions — Refer to page 187. Fusing — Fuse holders are included with the IFM. and blown fuse indicators are isolated into two groups of 10 terminals (eight fuse clips and blown fuse indicators). 1. refer to the Wiring System web site information on page 186. do not exceed the voltage and current ratings of the IFM. Pinout 1 2 3 B1 B2 B3 Pinout 1 2 3 B1 B2 B3 18 19 20 B18 B19 B20 18 19 20 B18 B19 B20 A1 A2 A11 A12 A1 A2 A3 A9 A10 A19 A20 A10 A11 A18 Blown Fuse Indicator Circuit A19 A20 Blown Fuse Indicator Circuit Publication 1492-TD008D-EN-P . refer to the Wiring System web site information on page 186. 4.January 2009 . Dimensions — Refer to page 187. For Field-Side Wiring Diagrams. This allows each group of input devices to reference a different power source. 2..Digital/Analog Programmable Controller Wiring Systems 81 1492-IFM20F-F24A-2 1492-RIFM20F-F24A-2 Fusible Extra Terminals with 24V AC/DC Blown Fuse Indicators 1492-IFM20F-F120-2 1492-RIFM20F-F120-2 Fusible Extra Terminals with 120V AC/DC Blown Fuse Indicators Application Notes Application Notes 1. fuse clips. 5. 82 Digital/Analog Programmable Controller Wiring Systems 1492-IFM20F-F120A-2 1492-RIFM20F-F120A-2 Fusible Extra Terminals with 120V AC/DC Blown Fuse Indicators 1492-IFM20F-F240-2 Fusible Extra Terminals with 240V AC/DC Blown Fuse Indicators Application Notes Application Notes 1. This allows each group of input devices to reference a different power source. 5. 4. do not exceed the voltage and current ratings of the IFM. fuse clips. Fusing — Fuse holders are included with the IFM. 5. 3. Compatibility — To ensure proper operation with the I/O module. 1. For Field-Side Wiring Diagrams. For Field-Side Wiring Diagrams. Fuses (5 x 20 mm) are not included. fuse clips. Wiring — Refer to the Label Section on page 181.January 2009 . 2. and blown fuse indicators are isolated into two groups of 10 terminals (eight fuse clips and blown fuse indicators). Isolation — The power bus. This allows each group of output devices to reference a different power source. 3. Dimensions — Refer to page 187. Wiring — Refer to the Label Section on page 181. 2. refer to the Wiring System web site information on page 186. Dimensions — Refer to page 187. Pinout 1 B1 B2 B3 Pinout 1 2 3 B1 B2 B3 2 3 18 19 20 B18 B19 B20 18 19 20 B18 B19 B20 A1 A2 A1 A2 A11 A12 A3 A9 A10 A19 A20 A10 A11 Blown Fuse Indicator Circuit A18 A19 A20 Blown Fuse Indicator Circuit Publication 1492-TD008D-EN-P . refer to the Wiring System web site information on page 186. Isolation — The power bus. Fusing — Fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included. and blown fuse indicators are isolated into two groups of 10 terminals (eight fuse clips and blown fuse indicators). 4. Compatibility — To ensure proper operation with the I/O module. do not exceed the voltage and current ratings of the IFM. Fuses (5 x 20 mm) are not included. do not exceed the voltage and current ratings of the IFM. Fuses (5 x 20 mm) are not included. For Field-Side Wiring Diagrams. refer to the Wiring System web site information on page 186. 2. a 1N4004 diode reverse-wired across a DC load).g. 4. Isolation — The fuse clips and blown fuse indicators are isolated into eight groups of terminals. Wiring — Refer to the Label Section on page 181.Digital/Analog Programmable Controller Wiring Systems 83 1492-IFM20F-FS-2 Fusible 8 Individually Isolated 120V AC/DC with Extra Terminals for Outputs 1492-IFM20F-FS24-2 Fusible 8 Individually Isolated with Extra Terminals and 24V AC/DC Blown Fuse Indicators Application Notes 1. Compatibility — To ensure proper operation with the I/O module. This allows each output device to reference a different power source. surge suppression must be used (e. Fusing — Fuse holders are included with the IFM. For Field-Side Wiring Diagrams. Isolation — The fuse clips are isolated into eight groups of terminals. do not exceed the voltage and current ratings of the IFM. Compatibility — To ensure proper operation with the I/O module. 5. 2. Dimensions — Refer to page 187. This allows each output device to reference a different power source.. Dimensions — Refer to page 187. Fusing — Fuse holders are included with the IFM. refer to the Wiring System web site information on page 186. 3. Wiring — Refer to the Label Section on page 181.January 2009 . When this IFM is used with a hard contact (relay) output circuit that switches an inductive load. Application Notes 1. 4. Pinout 10 3 5 (odd) 15 17 20 B8 B9 B10 B1 B2 B3 Pinout 10 3 5 (odd) 15 17 B8 B9 B10 A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 B1 B2 B3 1 2 4 6 8 12 14 16 18 19 A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 20 1 2 4 6 8 12 14 16 18 19 Blown Fuse Indicator Circuit Publication 1492-TD008D-EN-P . 5. 3. A2 A3 A4 11 A5 B14 2 A6 A7 A8 A9 A10 A11 A12 A13 19 A14 Blown Fuse Indicator Circuit Publication 1492-TD008D-EN-P .84 Digital/Analog Programmable Controller Wiring Systems 1492-IFM20F-FS24A-4 Fusible Two 4-Point Isolated Groups with 4 Terminals/Input and 24V AC/DC Blown Fuse LED Indicators Pinout 3 4 5 6 15 16 17 18 B6 B7 B8 B9 B10 B11 B12 B13 B1 B2 B3 B4 7 B5 Application Notes A1 1. Isolation — The fuse clips and blown fuse indicators are isolated into two groups of terminals. Fusing — Fuse holders are included with the IFM. 4. a 1N4004 diode reverse-wired across a DC load).January 2009 . Dimensions — Refer to page 187. do not exceed the voltage and current ratings of the IFM. 2.. surge suppression must be used (e. For Field-Side Wiring Diagrams. Wiring — Refer to the Label Section on page 181. 3. 5. Fuses (5 x 20 mm) are not included. refer to the Wiring System web site information on page 186. This allows each group of output devices to reference a different power source. Compatibility — To ensure proper operation with the I/O module.g. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load. 2. Compatibility — To ensure proper operation with the I/O module. 14 16 18 19 Blown Fuse Indicator Circuit Publication 1492-TD008D-EN-P .. For Field-Side Wiring Diagrams. refer to the Wiring System web site information on page 186.Digital/Analog Programmable Controller Wiring Systems 85 1492-IFM20F-FS120-2 Fusible 8 Individually Isolated with Extra Terminals and 120V AC/DC Blown Fuse LED Indicators Pinout 10 3 5 (odd) 15 17 20 1 2 4 6 8 12 B8 B9 B10 A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 B1 B2 B3 Application Notes 1. Wiring — Refer to the Label Section on page 181. surge suppression must be used (e. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load. an MOV wired across an AC load). do not exceed the voltage and current ratings of the IFM. 5. Dimensions — Refer to page 187. This allows each output device to reference a different power source. Isolation — The fuse clips and blown fuse indicators are isolated into eight groups of terminals. 3. Fusing — Fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.g. 4.January 2009 . Fuses (5 x 20 mm) are not included. 12 11 A15 B15 A7 19 B7 14 13 A8 B8 16 15 A9 B9 18 17 A10 B10 A18 B18 A17 B17 A16 B16 Blown Fuse Indicator Circuit Publication 1492-TD008D-EN-P . Wiring — Refer to the Label Section on page 181. This allows each output device to reference a different power source. 2. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load. 3.. Isolation — The fuse clips and blown fuse indicators are isolated into eight groups of terminals. Fusing — Ten fuse holders are included with the IFM. For Field-Side Wiring Diagrams.January 2009 . surge suppression must be used (e. 4.86 Digital/Analog Programmable Controller Wiring Systems 1492-IFM20F-FS120-4 Fusible 8 Individually Isolated with 4 Terminals/Output and 120V AC/DC Blown Fuse LED Indicators Pinout 2 3 A3 1 B3 4 5 A4 B4 6 7 A5 B5 8 9 A14 B14 A6 B6 A13 B13 A12 B12 A11 B11 Application Notes 1. refer to the Wiring System web site information on page 186.g. Dimensions — Refer to page 187. an MOV wired across an AC load). do not exceed the voltage and current ratings of the IFM. 5. Compatibility — To ensure proper operation with the I/O module. Compatibility — To ensure proper operation with the I/O module. 2.g. do not exceed the voltage and current ratings of the IFM.. 4. For Field-Side Wiring Diagrams. Dimensions — Refer to page 187. 11 A3 A4 A5 B14 2 A6 A7 A8 A9 A10 A11 A12 A13 19 A14 Blown Fuse Indicator Circuit Publication 1492-TD008D-EN-P . Fuses (5 x 20 mm) are not included. a 1N4004 diode reverse-wired across a DC load or an MOV across an AC load). Wiring — Refer to the Label Section on page 181. 5. 3.January 2009 . This allows each group of input devices to reference a different power source. Isolation — The fuse clips and blown fuse indicators are isolated into two groups of terminals. surge suppression must be used (e. refer to the Wiring System web site information on page 186. Fusing — Ten fuse holders are included with the IFM.Digital/Analog Programmable Controller Wiring Systems 87 1492-IFM20F-FS120A-4 Fusible Two 4-Point Isolated Groups with 4 Terminals/Input and 120V AC/DC Blown Fuse LED Indicators Pinout 3 4 5 6 15 16 17 18 B6 B7 B8 B9 B10 B11 B12 B13 B1 B2 B3 B4 7 B5 A1 A2 Application Notes 1. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load. . Fusing — Fuse holders are included with the IFM. 12 11 A7 19 B7 14 13 A8 B8 16 15 A9 B9 18 17 A10 B10 A15 B15 A16 B16 A17 B17 A18 B18 Blown Fuse Indicator Circuit Publication 1492-TD008D-EN-P . This allows each output device to reference a different power source. 4. For Field-Side Wiring Diagrams. Dimensions — Refer to page 187. Compatibility — To ensure proper operation with the I/O module.88 Digital/Analog Programmable Controller Wiring Systems 1492-IFM20F-FS240-4 Fusible 8 Individually Isolated with 4 Terminals/Output and 240V AC/DC Blown Fuse LED Indicators Pinout 2 3 A3 1 B3 4 5 A4 B4 6 7 A5 B5 8 9 A6 B6 A14 B14 A13 B13 A12 B12 A11 B11 Application Notes 1. a 1N4004 diode reverse-wired across a DC load or an MOV across an AC load). surge suppression must be used (e. refer to the Wiring System web site information on page 186. Isolation — The fuse clips and blown fuse indicators are isolated into eight groups of terminals. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load.January 2009 .g. 2. 5. Wiring — Refer to the Label Section on page 181. Fuses (5 x 20 mm) are not included. 3. do not exceed the voltage and current ratings of the IFM. Wiring — Refer to the Label Section on page 181. 3. 3. Compatibility — To ensure proper operation with the I/O module.Digital/Analog Programmable Controller Wiring Systems 89 1492-IFM40F 1492-RIFM40F Feed-Through Standard 132V AC/DC 1492-IFM40F-2 1492-RIFM40F-2 Feed-Through Extra Terminals (2 per I/O) 132V AC/DC Application Notes 1. Isolation — The power bus is isolated into four groups of 10 terminals. Dimensions — Refer to page 187. For Field-Side Wiring Diagrams. do not exceed the voltage and current ratings of the IFM. Wiring — Refer to the Label Section on page 181.January 2009 . 4. refer to the Wiring System web site information on page 186. Pinout 1 3 5 (odd) 35 37 39 A1 A2 A3 Pinout 1 3 5 (odd) 35 37 39 B18 B19 B20 B1 B2 B3 A18 A19 A20 2 4 6 (even) 36 38 40 B1 B2 B3 2 4 6 (even) B21 B22 B23 B18 B19 B20 36 38 40 B38 B39 B40 A1 A11 A21 A31 A2 A12 A22 A32 A9 A19 A29 A39 A10 A20 A30 A40 Publication 1492-TD008D-EN-P . 2. 2. Dimensions — Refer to page 187. refer to the Wiring System web site information on page 186. For Field-Side Wiring Diagrams. Compatibility — To ensure proper operation with the I/O module. Application Notes 1. This allows each group of the I/O devices to reference a different power source. do not exceed the voltage and current ratings of the IFM. January 2009 . 4. For Field-Side Wiring Diagrams. This allows the input devices connected to the left field-side terminal block to reference a different power source than the input devices connected to the right field-side terminal block. Dimensions — Refer to page 187. do not exceed the voltage and current ratings of the IFM. refer to the Wiring System web site information on page 186. Wiring — Refer to the Label Section on page 181. 3.90 Digital/Analog Programmable Controller Wiring Systems 1492-IFM40F-3 Feed-Through 3-Wire Sensor Type Input Devices 60V AC/DC Pinout TB1 5 (odd) 35 C16 B1 B2 C1 TB2 1 3 37 39 B17 B18 A1 A2 TB1 A17 A18 Application Notes 1. 2. Isolation — The power busses are isolated into two groups of 18 terminals. TB2 6 (even) 36 C16 B1 B2 C1 2 4 38 40 B17 B18 A1 A2 Even Odd A17 A18 Publication 1492-TD008D-EN-P . Compatibility — To ensure proper operation with the I/O module. refer to the Wiring System web site information on page 186. Compatibility — To ensure proper operation with the I/O module. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load.. a 1N4004 diode reverse-wired across a DC load). surge suppression must be used (e. Wiring — The LEDs are powered off the two-position terminal block.g. Isolation — The LEDs are connected to one common. 2. 3.Digital/Analog Programmable Controller Wiring Systems 91 1492-IFM40D24 1492-RIFM40D24 LED Indicating Standard with 24V AC/DC LEDs Pinout 1 3 5 (odd) 35 37 39 A18 A19 A20 A1 A2 A3 LED 0-15 LED 16-31 Application Notes 1. Make only one connection to the power source for normal operation. 2 4 6 (even) 36 38 40 B1 B2 B3 B18 B19 B20 Publication 1492-TD008D-EN-P . All of the I/O devices used must reference the same power source. Refer to the Label Section on page 181.January 2009 . 4. For Field-Side Wiring Diagrams. do not exceed the voltage and current ratings of the IFM. Dimensions — Refer to page 187. 3. Dimensions — Refer to page 187.92 Digital/Analog Programmable Controller Wiring Systems 1492-IFM40D24-2 LED Indicating24V AC/DC LEDs and Extra Terminals for Outputs Pinout 1 3 5 (odd) 19 21 (odd) 35 37 39 B18 B19 B20 B10 B11 B1 B2 B3 A1 A2 A11 A12 A9 A10 2 4 6 (even) 20 A19 A20 B21 B22 B23 B30 B31 Application Notes 1. refer to the Wiring System web site information on page 186. Wiring — Refer to the Label Section on page 181.January 2009 . 2. do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load. Isolation — The power bus and LEDs are isolated into four groups of 10 terminals (eight LEDs). For Field-Side Wiring Diagrams. surge suppression must be used (e.g.. 4. a 1N4004 diode reverse-wired across a DC load). This allows each group of output devices to reference a different power source. 22 (even) 36 38 40 B38 B39 B40 A21 A31 A32 LED Circuit A22 A29 A30 A39 A40 Publication 1492-TD008D-EN-P . Compatibility — To ensure proper operation with the I/O module. Wiring — Refer to the Label Section on page 181. Compatibility — To ensure proper operation with the I/O module. surge suppression must be used (e. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load. For Field-Side Wiring Diagrams. Isolation — The power bus and LEDs are isolated into four groups of 10 terminals (eight LEDs). Dimensions — Refer to page 187. 2. do not exceed the voltage and current ratings of the IFM. This allows each group of input devices to reference a different power source.January 2009 . refer to the Wiring System web site information on page 186. a 1N4004 diode reverse-wired across a DC load).. 3.g. 4.Digital/Analog Programmable Controller Wiring Systems 93 1492-IFM40D24A-2 1492-RIFM40D24A-2 LED Indicating24V AC/DC LEDs and Extra Terminals for Inputs Pinout 1 3 5 (odd) 19 21 (odd) 35 37 39 A1 A2 A11 A12 B18 B19 B20 B10 B11 B1 B2 B3 A9 A10 2 4 6 (even) A19 A20 B21 B22 B23 Application Notes 1. 20 22 (even) 36 38 40 A21 A31 A32 B30 B31 B38 B39 B40 LED Circuit A22 A29 A30 A39 A40 Publication 1492-TD008D-EN-P . 2.g. an MOV wired across an AC load). Dimensions — Refer to page 187.January 2009 .94 Digital/Analog Programmable Controller Wiring Systems 1492-IFM40D120-2 LED Indicating 120V AC LEDs and Extra Terminals for Outputs Pinout 1 1 3 3 5 5 (odd) (odd) 19 19 21 21 (odd) (odd) 35 35 37 37 39 39 B1 B1 B2 B2 B3 B3 B10 B10 B11 B11 B18 B18 B19 B19 B20 B20 A1 A1 A2 A2 A9 A9 A10 A10 2 2 4 4 6 6 (even) (even) 20 20 22 22 (even) (even) 36 36 38 38 40 40 A11 A11 A12 A12 A19 A19 A20 A20 B21 B21 B22 B22 B23 B23 B30 B30 B31 B31 B38 B38 B39 B39 B40 B40 Application Notes 1.. For Field-Side Wiring Diagrams. A21 A21 A22 A22 A31 A31 A32 A32 A39 A39 A40 A40 LED Circuit A29 A29 A30 A30 Publication 1492-TD008D-EN-P . do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load. Wiring — Refer to the Label Section on page 181. Isolation — The power bus and LEDs are isolated into four groups of 10 terminals (eight LEDs). 4. Compatibility — To ensure proper operation with the I/O module. 3. refer to the Wiring System web site information on page 186. This allows each group of output devices to reference a different power source. surge suppression must be used (e. an MOV wired across an AC load). do not exceed the voltage and current ratings of the IFM. 2. Dimensions — Refer to page 187. surge suppression must be used (e. This allows each group of input devices to reference a different power source. For Field-Side Wiring Diagrams.g. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load.January 2009 . Compatibility — To ensure proper operation with the I/O module.Digital/Analog Programmable Controller Wiring Systems 95 1492-IFM40D120A-2 LED Indicating 120V AC LEDs and Extra Terminals for Inputs Pinout 1 1 3 5 3 5 (odd) 19 21 B10 B1 B2 B3 B1 B2 B3 (odd) 19 B10 B11 (odd) 35 37 B18 B19 B20 A1 A2 A11 A12 21 B11 (odd) 35 37 39 39 B18 B19 B20 A1 A9 A19 A11 A12 A20 B21 A2 A10 2 4 6 A9 A10 A19 B22 A20B23 B21 B30 B31 2 (even) 4 20 6 22 B22 B23 Application Notes 1.. refer to the Wiring System web site information on page 186. Isolation — The power bus and LEDs are isolated into four groups of 10 terminals (eight LEDs). Wiring — Refer to the Label Section on page 181. 4. (even) (even) 20 36 38 B38 B39 B40 A21 A22 A31 A32 B30 B31 22 40 (even) 36 38 A29 A39 B38 B39 B40 40 A30 A40 A21 A22 A31 A32 LED Circuit A29 A30 A39 A40 Publication 1492-TD008D-EN-P . 3. Isolation — The power busses and LEDs are isolated into two groups of 18 terminals (16 LEDs). When this IFM is used with a hard contact (relay) output circuit that switches an inductive load.g. 3.96 Digital/Analog Programmable Controller Wiring Systems 1492-IFM40D24-3 LED Indicating 3-Wire Sensor with 24V AC/DC LEDs Pinout TB1 5 (odd) 35 C16 C1 TB2 1 3 37 39 B17 B18 A1 A2 B1 B2 TB1 A17 A18 TB2 6 (even) 36 C16 C1 Application Notes 1. surge suppression must be used (e. Dimensions — Refer to page 187. a 1N4004 diode reverse-wired across a DC load). do not exceed the voltage and current ratings of the IFM. This allows the input devices connected to the left field-side terminal block to reference a different power source than the input devices connected to the right field-side terminal block.January 2009 . B1 B2 2 4 38 40 B17 B18 A1 A2 LED Circuit A17 A18 Publication 1492-TD008D-EN-P . Wiring — Refer to the Label Section on page 181. Compatibility — To ensure proper operation with the I/O module. 4. refer to the Wiring System web site information on page 186. 2. For Field-Side Wiring Diagrams.. 2. Isolation — There are 16 individually isolated channels. do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load. 3. A2 A15 A16 A17 A18 A31 A32 Publication 1492-TD008D-EN-P ..Digital/Analog Programmable Controller Wiring Systems 97 1492-IFM40DS24-4 LED Indicating 16 Individually Isolated with 24/48V AC/DC LEDs and 4 Terminals/Output Pinout 5 (odd) 19 21 (odd) 35 6 (even) 20 22 (even) 36 B24 B16 B17 B32 B9 B8 B25 B1 A1 Application Notes 1. 5. Compatibility — To ensure proper operation with the I/O module.g. a 1N4004 diode reverse-wired across a DC load). Extra Terminals — Two field-side terminals are internally connected on the IFM for each channel. and are available for power source common connections. surge suppression must be used (e. Dimensions — Refer to page 187.January 2009 . LED returns are individually isolated. refer to the Wiring System web site information on page 186. Wiring — Refer to the Label Section on page 181. For Field-Side Wiring Diagrams. 4. 2. Extra Terminals — Two field-side terminals are internally connected on the IFM for each channel. LED returns are individually isolated. 5. surge suppression must be used (e. refer to the Wiring System web site information on page 186. do not exceed the voltage and current ratings of the IFM. Dimensions — Refer to page 187.. Compatibility — To ensure proper operation with the I/O module.January 2009 . 3. Wiring — Refer to the Label Section on page 181. (odd) (odd) 35 35 B32 B32 A1 A1 A2 A2 A31 A31 A32 A32 Publication 1492-TD008D-EN-P . For Field-Side Wiring Diagrams. a 1N4004 diode reverse-wired across a DC load). and are available for power source common connections. Isolation — There are 16 individually isolated channels. 4.g. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load.98 Digital/Analog Programmable Controller Wiring Systems 1492-IFM40DS24A-4 LED Indicating 16 Individually Isolated with 24V AC/DC LEDs and 4 Terminals/Input Pinout 6 6 (even) (even) 20 20 B16 B16 B9 B9 5 5 (odd) (odd) 19 19 22 22 (even) (even) 36 36 B1 B1 B8 B8 B17 B17 B24 B24 Application Notes 21 21 B25 B25 1. an MOV wired across an AC load). LED returns are individually isolated. 3. 4.January 2009 . Extra Terminals — Two field-side terminals are internally connected on the IFM for each channel. 5. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load.g. do not exceed the voltage and current ratings of the IFM. surge suppression must be used (e. Dimensions — Refer to page 187. Compatibility — To ensure proper operation with the I/O module. refer to the Wiring System web site information on page 186. Wiring — Refer to the Label Section on page 181. For Field-Side Wiring Diagrams. 2. and are available for power source common connections..Digital/Analog Programmable Controller Wiring Systems 99 1492-IFM40DS120-4 LED Indicating 16 Individually Isolated with 120V AC and 4 Terminals/Output Pinout 5 (odd) 19 21 (odd) 35 6 (even) 20 22 (even) 36 B24 B16 B17 B32 B9 B8 B25 B1 A1 Application Notes 1. Isolation — There are 16 individually isolated channels. A2 A15 A16 A17 A18 A31 A32 Publication 1492-TD008D-EN-P . Wiring — Refer to the Label Section on page 181.. Isolation — There are 16 individually isolated channels. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load. an MOV wired across an AC load). 2. 5. For Field-Side Wiring Diagrams.g. do not exceed the voltage and current ratings of the IFM. 4. Dimensions — Refer to page 187. LED returns are individually isolated. 3. refer to the Wiring System web site information on page 186. A31 A32 Publication 1492-TD008D-EN-P . Compatibility — To ensure proper operation with the I/O module. Extra Terminals — Two field-side terminals are internally connected on the IFM for each channel.100 Digital/Analog Programmable Controller Wiring Systems 1492-IFM40DS120A-4 LED Indicating 16 Individually Isolated with 120V AC LEDs and 4 Terminals/Input Pinout 6 (even) 20 B16 B9 5 (odd) 19 22 (even) 36 B1 B8 B17 B24 Application Notes 21 B25 (odd) 35 B32 A1 A2 1. and are available for power source common connections.January 2009 . surge suppression must be used (e. surge suppression must be used (e. Compatibility — To ensure proper operation with the I/O module. refer to the Wiring System web site information on page 186. Extra Terminals — Two field-side terminals are internally connected on the IFM for each channel. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load. Dimensions — Refer to page 187.. 4. 2. LED returns are individually isolated.g. and are available for power source common connections. 5. 3. For Field-Side Wiring Diagrams.Digital/Analog Programmable Controller Wiring Systems 101 1492-IFM40DS240A-4 LED Indicating 16 Individually Isolated with 240V AC LEDs and 4 Terminals/Input Pinout 6 (even) 36 B32 B17 5 (odd) 35 A17 A32 A1 B1 Application Notes 1. do not exceed the voltage and current ratings of the IFM. an MOV wired across an AC load). Isolation — There are 16 individually isolated channels.January 2009 . Wiring — Refer to the Label Section on page 181. A16 B16 Publication 1492-TD008D-EN-P . Fusing — Fuse holders are included with the IFM. 36 38 40 B38 B39 B40 A1 A2 A11 A12 A21 A22 A31 A32 A9 A10 A19 A20 A29 A30 A39 A40 Publication 1492-TD008D-EN-P . Compatibility — To ensure proper operation with the I/O module. For Field-Side Wiring Diagrams.January 2009 . 5. 2. 3.102 Digital/Analog Programmable Controller Wiring Systems 1492-IFM40F-F-2 Fusible 120V AC/DC with Extra Terminals for Outputs Pinout 1 3 5 (odd) 35 37 39 B18 B19 B20 B1 B2 B3 2 4 6 (even) B21 B22 B23 Application Notes 1. This allows each group of output devices to reference a different power source. Fuses (5 x 20 mm) are not included. refer to the Wiring System web site information on page 186. do not exceed the voltage and current ratings of the IFM. Wiring — Refer to the Label Section on page 181. 4. Dimensions — Refer to page 187. Isolation — The power bus and fuse clips are isolated into four groups of 10 terminals (eight fuse clips). Fusing — Fuse holders are included with the IFM.January 2009 . Wiring — Refer to the Label Section on page 181. Isolation — The power bus. a 1N4004 diode reverse-wired across a DC load). 5. do not exceed the voltage and current ratings of the IFM. 3. fuse clips. Dimensions — Refer to page 187. Fuses (5 x 20 mm) are not included. 2. Compatibility — To ensure proper operation with the I/O module.g. 4. For Field-Side Wiring Diagrams. This allows each group of output devices to reference a different power source.. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load. A2 A9 A10 A19 A20 A29 A30 A39 A40 Blown Fuse Indicator Circuit Publication 1492-TD008D-EN-P .Digital/Analog Programmable Controller Wiring Systems 103 1492-IFM40F-F24-2 1492-RIFM40F-F24-2 Fusible Extra Terminals with 24V AC/DC Blown Fuse LED Indicators for Outputs Pinout 1 3 5 (odd) 35 37 39 2 4 6 (even) 36 38 40 A1 A11 A12 A21 A22 B38 B39 B40 A31 A32 B18 B19 B20 B21 B22 B23 B1 B2 B3 Application Notes 1. refer to the Wiring System web site information on page 186. and blown fuse indicators are isolated into four groups of 10 terminals (eight fuse clips and blown fuse indicators). surge suppression must be used (e. 4 isolated groups. surge suppression must be used (e. do not exceed the voltage and current ratings of the IFM. Fuses (5 x 20 mm) are not included. Fusing — Fuse holders are included with the IFM. Compatibility — To ensure proper operation with the I/O module.g. A1 A2 A3 A4 A5 A6 A7 A8 A9 19 A10 35 A11 A12 A13 A14 A15 A16 A17 A18 A19 A20 Blown Fuse Indicator Circuit COM +V Publication 1492-TD008D-EN-P . a 1N4004 diode reverse-wired across a DC load). This allows use with 4 separate power supplies.January 2009 . 5. For Field-Side Wiring Diagrams. Wiring — Refer to the Label Section on page 181. 3.05 mA) LED circuit. The fuse clips and blown fuse indicators are isolated into 4 groups of terminals. 2 terminals/output Pinout 6 (even) 36 B18 B3 5 7 9 11 13 15 17 B1 B2 21 23 25 27 29 31 33 B19 B20 Application Notes 1. 2..104 Digital/Analog Programmable Controller Wiring Systems 1492-IFM40F-F24D-2 16 Individually fused with 24V DC blown fuse low leakage (0. Dimensions — Refer to page 187. Isolation — Each point is individually fused. refer to the Wiring System web site information on page 186. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load. 4. Extra Terminals — Two field-side terminals are internally connected on the IFM for each channel.Digital/Analog Programmable Controller Wiring Systems 105 1492-IFM40F-F24AD-4 Individually Fused w/24V DC blown fuse low leakage (0.05 mA) LED circuit. 5. Fusing — Fuse holders are included with the IFM. 6. Compatibility — To ensure proper operation with the I/O module. 4 terminals/input Pinout A2 B2 5 (even) 6 A8 (odd) B8 B3 A3 11 12 A10 B10 13 (even) 14 A16 (odd) B16 A9 B9 A11 B11 Application Notes 1. This allows use of 4 separate power supplies. Dimensions — Refer to page 187. 2. 19 20 A17 B17 A18 B18 21 (even) 22 A24 (odd) B24 B19 A19 27 28 A25 B25 A26 B26 29 (even) 30 A32 (odd) B32 B27 A27 35 36 A33 B33 Blown Fuse Indicator Circuit +DC COM A3 .January 2009 . do not exceed the voltage and current ratings of the IFM. 4. Wiring — Refer to the Label Section on page 181. 3. refer to the Wiring System web site information on page 186. Isolation — Each point is individually fused. and are available for power source common connections. The fuse clips and blown fuse indicators are isolated into 4 groups. Fuses (5 x 20 mm) are not included.A33 (ODD) Publication 1492-TD008D-EN-P . 4 isolated groups. For Field-Side Wiring Diagrams. Isolation — The power bus. Wiring — Refer to the Label Section on page 181. do not exceed the voltage and current ratings of the IFM. and blown fuse indicators are isolated into four groups of 10 terminals (eight fuse clips and blown fuse indicators). surge suppression must be used (e. This allows each group of output devices to reference a different power source. Compatibility — To ensure proper operation with the I/O module.106 Digital/Analog Programmable Controller Wiring Systems 1492-IFM40F-F120-2 Fusible Extra Terminals with 120V AC/DC Blown Fuse LED Indicators for Outputs Pinout 1 3 5 (odd) 35 37 39 2 4 6 (even) 36 38 40 A1 A2 A11 A12 A21 A22 B38 B39 B40 A31 A32 B18 B19 B20 B21 B22 B23 B1 B2 B3 Application Notes 1. 5.January 2009 .. an MOV wired across an AC load). Dimensions — Refer to page 187.g. A9 A10 A19 A20 A29 A30 A39 A40 Blown Fuse Indicator Circuit Publication 1492-TD008D-EN-P . refer to the Wiring System web site information on page 186. 2. Fusing — Fuse holders are included with the IFM. 3. fuse clips. 4. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load. Fuses (5 x 20 mm) are not included. For Field-Side Wiring Diagrams. Isolation — The fuse clips and blown fuse indicators are isolated into 16 groups of terminals.. Dimensions — Refer to page 187. Dimensions — Refer to page 187. For Field-Side Wiring Diagrams. 5. do not exceed the voltage and current ratings of the IFM. Pinout 6 (even) 36 B18 B3 Pinout 6 B3 (even) 36 B18 5 (odd) 35 A3 A18 5 (odd) 35 A3 A18 Blown Fuse Indicator Circuit Publication 1492-TD008D-EN-P . 4. Fuses (5 x 20 mm) are not included. surge suppression must be used (e. Application Notes 1. For Field-Side Wiring Diagrams. refer to the Wiring System web site information on page 186. 3. Compatibility — To ensure proper operation with the I/O module. a 1N4004 diode reverse-wired across a DC load).January 2009 . Fusing — Fuse holders are included with the IFM. 5. Compatibility — To ensure proper operation with the I/O module. Isolation — The fuse clips are isolated into 16 groups of terminals. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load. This allows each output device to reference a different power source. 4. 2. refer to the Wiring System web site information on page 186.g. Fusing — Fuse holders are included with the IFM. Wiring — Refer to the Label Section on page 181. This allows each output device to reference a different power source. Fuses (5 x 20 mm) are not included. 3. do not exceed the voltage and current ratings of the IFM. Wiring — Refer to the Label Section on page 181. 2.Digital/Analog Programmable Controller Wiring Systems 107 1492-IFM40F-FS-2 Fusible 16 Individually Isolated with Extra Terminals for 120V AC/DC Outputs 1492-IFM40F-FS24-2 Fusible 16 Individually Isolated with Extra Terminals and 24V AC/DC Blown Fuse LED Indicators for Outputs Application Notes 1. a 1N4004 diode reverse-wired across a DC load or an MOV for AC loads). Wiring — Refer to the Label Section on page 181. and are available for power source common connections. Extra Terminals — Two field-side terminals are internally connected on the IFM for each channel. 5.108 Digital/Analog Programmable Controller Wiring Systems 1492-IFM40F-FS24-4 Fusible Individually Isolated with 24V AC/DC Blown Fuse Indicators and 4 Terminals/Output Pinout 5 6 A18 B18 A2 B2 7 8 A19 B19 A3 B3 33 A32 B32 Application Notes 34 1.. 6. 4. Compatibility — To ensure proper operation with the I/O module. do not exceed the voltage and current ratings of the IFM. Isolation — The fuse clips and blown fuse indicators are isolated into 16 groups of terminals. 3. Fuses (5 x 20 mm) are not included. refer to the Wiring System web site information on page 186.January 2009 . For Field-Side Wiring Diagrams. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load.g. Dimensions — Refer to page 187. surge suppression must be used (e. This allows each output device to reference a different power source. Fusing — 20 fuse holders are included with the IFM. A16 B16 35 36 A33 B33 A17 B17 Blown Fuse Indicator Circuit Publication 1492-TD008D-EN-P . 2. 6.January 2009 . do not exceed the voltage and current ratings of the IFM.. a 1N4004 diode reverse-wired across a DC load or an MOV for AC loads).Digital/Analog Programmable Controller Wiring Systems 109 1492-IFM40F-FS-4 Fusible 16 Individually Isolated 240V AC/DC with 4 Terminals/Output Pinout 5 6 A18 B18 A2 B2 7 8 A19 B19 A3 B3 33 A32 B32 :Application Notes 34 1. Dimensions — Refer to page 187. 2. Fusing — 20 fuse holders are included with the IFM. Isolation — The fuse clips are isolated into 16 groups of terminals. For Field-Side Wiring Diagrams. Fuses (5 x 20 mm) are not included. This allows each output device to reference a different power source. refer to the Wiring System web site information on page 186. 4. Compatibility — To ensure proper operation with the I/O module. Wiring — Refer to the Label Section on page 181. A16 B16 35 36 A33 B33 A17 B17 Publication 1492-TD008D-EN-P . surge suppression must be used (e. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load.g. 3. 5. Extra Terminals — Two field-side terminals are internally connected on the IFM for each channel. and are available for power source common connections. Wiring — Refer to the Label Section on page 181.110 Digital/Analog Programmable Controller Wiring Systems 1492-IFM40F-FS120-2 1492-RIFM40F-FS120-2 Fusible 16 Individually Isolated with Extra Terminals and 120V AC/DC Blown Fuse LED Indicators for Outputs Pinout 6 (even) 36 B18 B3 5 (odd) 35 A3 A18 Blown Fuse Indicator Circuit Application Notes 1. Fuses (5 x 20 mm) are not included. 2. Fusing — Fuse holders are included with the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load. do not exceed the voltage and current ratings of the IFM. a 1N4004 diode reverse-wired across a DC load or an MOV across an AC load). Isolation — The fuse clips and blown fuse indicators are isolated into 16 groups of terminals. Compatibility — To ensure proper operation with the I/O module. 5. For Field-Side Wiring Diagrams. 4. Dimensions — Refer to page 187. surge suppression must be used (e.. Publication 1492-TD008D-EN-P .g. This allows each output device to reference a different power source.January 2009 . 3. refer to the Wiring System web site information on page 186. Wiring — Refer to the Label Section on page 181. For Field-Side Wiring Diagrams.January 2009 . surge suppression must be used (e. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load. This allows each output device to reference a different power source.. Isolation — The fuse clips and blown fuse indicators are isolated into 16 groups of terminals. Dimensions — Refer to page 187. 5. a 1N4004 diode reverse-wired across a DC load or an MOV across an AC load). and are available for power source common connections. 2. refer to the Wiring System web site information on page 186. Fusing — Fuse holders are included with the IFM.Digital/Analog Programmable Controller Wiring Systems 111 1492-IFM40F-FS120-4 1492-IFM40F-FS120-4 Fusible 16 Individually Isolated with 120V AC/DC Blown Fuse LED Indicators & 4 Terminals/Output Pinout 5 6 A3 B3 7 8 A5 B5 (even) A4 B4 A2 B2 (odd) 33 34 A31 B31 35 36 A33 B33 A32 B32 A30 B30 Blown Fuse Indicator Circuit Application Notes 1. Extra Terminals — Two field-side terminals are internally connected on the IFM for each channel. 4.g. Publication 1492-TD008D-EN-P . 3. Fuses (5 x 20 mm) are not included. do not exceed the voltage and current ratings of the IFM. 6. Compatibility — To ensure proper operation with the I/O module. 4. For Field-Side Wiring Diagrams. Isolation — The fuse clips and blown fuse indicators are isolated into 16 groups of terminals.112 Digital/Analog Programmable Controller Wiring Systems 1492-IFM40F-FS240-4 Fusible 16 Individually Isolated with 240V AC/DC Blown Fuse LED Indicators & 4 Terminals/Output Pinout 5 6 A18 B18 A2 B2 7 8 A19 B19 A3 B3 33 34 A32 B32 A16 B16 35 A33 B33 Application Notes 1. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load. This allows each output device to reference a different power source. refer to the Wiring System web site information on page 186. 5. Extra Terminals — Two field-side terminals are internally connected on the IFM for each channel. Fuses (5 x 20 mm) are not included. Wiring — Refer to the Label Section on page 181. Compatibility — To ensure proper operation with the I/O module. 3. Dimensions — Refer to page 187. Fusing — Fuse holders are included with the IFM. and are available for power source common connections. 6. surge suppression must be used (e. do not exceed the voltage and current ratings of the IFM.g. a 1N4004 diode reverse-wired across a DC load or an MOV across an AC load). 36 A17 B17 Blown Fuse Indicator Circuit Publication 1492-TD008D-EN-P .. 2.January 2009 . Isolation — The fuse clips and blown fuse indicators are isolated into 16 groups of terminals. do not exceed the voltage and current ratings of the IFM. 6. Fusing — Fuse holders are included with the IFM. Dimensions — Refer to page 187. Extra Terminals — Two field-side terminals are internally connected on the IFM for each channel. 5. and are available for power source common connections. Fuses (5 x 20 mm) are not included. Blown Fuse Indicator Circuit Publication 1492-TD008D-EN-P . 4.January 2009 . 2. This allows each input device to reference a different power source. 3. For Field-Side Wiring Diagrams.Digital/Analog Programmable Controller Wiring Systems 113 1492-IFM40F-FS24A-4 Fusible 16 Individually Isolated 24V AC/DC with 4 Terminals/Input Pinout A2 B2 5 6 A4 B4 7 8 (even) (odd) A30 B30 33 34 A32 B32 35 36 A33 B33 A31 B31 A5 B5 A3 B3 Application Notes 1. Compatibility — To ensure proper operation with the I/O module. Wiring — Refer to the Label Section on page 181. refer to the Wiring System web site information on page 186. Fusing — Fuse holders are included with the IFM. This allows each input device to reference a different power source. 6. 3. Pinout A2 B2 5 6 A4 B4 7 8 (even) A5 B5 A3 B3 Pinout A2 B2 5 6 A4 B4 7 8 (even) (odd) A30 B30 33 A31 B31 A32 B32 A5 B5 A3 B3 (odd) A30 B30 33 34 A32 B32 35 36 A33 B33 A31 B31 34 35 36 A33 B33 Blown Fuse Indicator Circuit Publication 1492-TD008D-EN-P . Fuses (5 x 20 mm) are not included. For Field-Side Wiring Diagrams. Wiring — Refer to the Label Section on page 181. Dimensions — Refer to page 187.114 Digital/Analog Programmable Controller Wiring Systems 1492-IFM40F-FSA-4 Fusible 16 Individually Isolated 120V AC/DC 4 Terminals/Input 1492-IFM40F-FS120A-4 1492-RIFM40F-FS120A-4 Fusible 16 Individually Isolated with 120V AC/DC Blown Fuse LED Indicators & 4 Terminals/Input Application Notes 1. Isolation — The fuse clips are isolated into 16 groups of terminals. and are available for power source common connections. Wiring — Refer to the Label Section on page 181. do not exceed the voltage and current ratings of the IFM. and are available for power source common connections. 5. Dimensions — Refer to page 187. do not exceed the voltage and current ratings of the IFM. Isolation — The fuse clips and blown fuse indicators are isolated into 16 groups of terminals. 4. 5. Compatibility — To ensure proper operation with the I/O module. 2. Application Notes 1. Fuses (5 x 20 mm) are not included. This allows each input device to reference a different power source. 4. Extra Terminals — Two field-side terminals are internally connected on the IFM for each channel. 6. Compatibility — To ensure proper operation with the I/O module. 2. For Field-Side Wiring Diagrams. Fusing — Fuse holders are included with the IFM.January 2009 . refer to the Wiring System web site information on page 186. 3. refer to the Wiring System web site information on page 186. Extra Terminals — Two field-side terminals are internally connected on the IFM for each channel. Digital/Analog Programmable Controller Wiring Systems 115 1492-IFM40F-FS240A-4 Fusible 16 Individually Isolated with 240V AC/DC Blown Fuse LED Indicators and 4 Terminals/Input Pinout A2 B2 5 6 A4 B4 7 8 (even) (odd) A30 B30 33 34 A32 B32 35 36 A33 B33 A31 B31 A5 B5 A3 B3 Blown Fuse Indicator Circuit Application Notes 1. refer to the Wiring System web site information on page 186. 2. do not exceed the voltage and current ratings of the IFM. Publication 1492-TD008D-EN-P . 5. This allows each input device to reference a different power source. and are available for power source common connections. Isolation — The fuse clips and blown fuse indicators are isolated into 16 groups of terminals. Dimensions — Refer to page 187.January 2009 . Extra Terminals — Two field-side terminals are internally connected on the IFM for each channel. Compatibility — To ensure proper operation with the I/O module. Fuses (5 x 20 mm) are not included. Wiring — Refer to the Label Section on page 181. For Field-Side Wiring Diagrams. Fusing — Fuse holders are included with the IFM. 4. 3. 5. Compatibility — To ensure proper operation with the I/O module. do not exceed the voltage and current ratings of the XIM. 2. Wiring — Refer to the Label Section on page 181. For Field-Side Wiring Diagrams.116 Digital/Analog Programmable Controller Wiring Systems 1492-XIM2024-8R Relay Master (LED Indicating) 20-Pin Master with Eight (8) 24V DC Relays Pinout CN ~ ~ K0 TB A3 3 A4 A5 A6 ~ ~ 4 K1 A7 A8 B3 ~ ~ 5 K2 B4 B5 B6 ~ ~ 6 K3 B7 B8 B9 ~ ~ 7 K4 B10 B11 B12 ~ ~ 8 K5 B13 B14 A9 ~ ~ Application Notes 1. With expansion module and cable (included with expansion module) can expand to 16 relays. 9 K6 A10 A11 A12 ~ ~ 10 K7 A13 A14 20 B16 7 CJ OUT 8 19 1 B15 B1 2 B2 1 CJOUT 2 CN 11 12 13 14 15 16 17 18 CJOUT 20 24 28 30 32 31 34 33 Publication 1492-TD008D-EN-P . 6.January 2009 . Maximum Relay Switching — Refer to page 192. LEDs provide PLC output ON/OFF indication. 3. Dimensions — Refer to page 187. refer to the Wiring System web site information on page 186. 4. January 2009 . 2. For Field-Side Wiring Diagrams. 6. Compatibility — To ensure proper operation with the I/O module. Dimensions — Refer to page 187. 4. refer to the Wiring System web site information on page 186. 3. 20 B16 7 CJ OUT 8 19 1 B15 B1 2 B2 1 CJOUT 2 CN 11 12 13 14 15 16 17 18 CJOUT 20 24 28 30 32 31 34 33 Publication 1492-TD008D-EN-P . LEDs provide PLC output ON/OFF indication. Maximum Relay Switching — Refer to page 192.Digital/Analog Programmable Controller Wiring Systems 117 1492-XIM20120-8R Relays Masters (LED Indicating) 20-Pin Master with Eight (8) 120V AC Relays Pinout CN ~ ~ K0 TB A3 3 A4 A5 A6 ~ ~ 4 K1 A7 A8 B3 ~ ~ 5 K2 B4 B5 B6 ~ ~ 6 K3 B7 B8 B9 ~ ~ 7 K4 B10 B11 B12 ~ ~ 8 K5 B13 B14 A9 ~ ~ 9 K6 A10 A11 A12 Application Notes 10 ~ ~ K7 A13 A14 1. Wiring — Refer to the Label Section on page 181. With expansion module and cable (included with expansion module) can expand to 16 relays. do not exceed the voltage and current ratings of the XIM. 5. No expansion capability. Compatibility — To ensure proper operation with the I/O module. LEDs provide PLC output ON/OFF indication. 5. do not exceed the voltage and current ratings of the XIM. 3. 2. Maximum Relay Switching — Refer to page 192. For Field-Side Wiring Diagrams. Wiring — Refer to the Label Section on page 181. ~ ~ 12 K 25 ~ ~ 13 K 26 ~ ~ 14 K 27 ~ ~ 15 K 28 ~ ~ 16 K 29 ~ ~ 17 K 30 ~ ~ 18 K 31 20 19 26 25 TB 1 1 2 1 2 Publication 1492-TD008D-EN-P . 4. refer to the Wiring System web site information on page 186.118 Digital/Analog Programmable Controller Wiring Systems 1492-XIM2024-16R Relays Master (LED Indicating) 20-Pin Master with Sixteen (16) 24V DC Relays Pinout 1492-XIM2024-16R TB 1 K 16 C N 3 ~ ~ 4 K 17 ~ ~ 5 K 18 ~ ~ 6 K 19 ~ ~ 7 K 20 ~ ~ 8 K 21 ~ ~ 9 K 22 ~ ~ 10 K 23 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 ~ ~ 11 K 24 TB 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 TB 2 Application Notes 1. 6.January 2009 . Dimensions — Refer to page 187. Wiring — Refer to the Label Section on page 181. No expansion capability.January 2009 . refer to the Wiring System web site information on page 186. Dimensions — Refer to 187. 3. 12 K1 ~ ~ 13 K2 ~ ~ 14 K3 ~ ~ 15 K4 ~ ~ 16 K5 ~ ~ 17 K6 ~ ~ 18 K7 26 20 19 1 2 25 TB1 1 2 Publication 1492-TD008D-EN-P . 6. For Field-Side Wiring Diagrams. Compatibility — To ensure proper operation with the I/O module. LEDs provide PLC output ON/OFF indication. Maximum Relay Switching — Refer to page 192. do not exceed the voltage and current ratings of the XIM. 2. 5.Digital/Analog Programmable Controller Wiring Systems 119 1492-XIM2024-16RF Relay Master (LED Indicating) 20-Pin Master with Sixteen (16) 24V DC Relays with Fusing Pinout 1492-XIM2024-16RF CN ~ ~ K0 TB1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 TB2 3 ~ ~ 4 K1 ~ ~ 5 K2 ~ ~ 6 K3 ~ ~ 7 K4 ~ ~ 8 K5 ~ ~ 9 K6 ~ ~ K7 10 ~ ~ 11 K0 TB2 ~ ~ Application Notes 1. 4. 2. 3.January 2009 . No expansion capability. 12 K 25 ~ ~ 13 K 26 ~ ~ 14 K 27 ~ ~ 15 K 28 ~ ~ 16 K 29 ~ ~ 17 K 30 ~ ~ 18 K 31 20 19 26 25 TB 1 1 2 1 2 Publication 1492-TD008D-EN-P . refer to the Wiring System web site information on page 186. For Field-Side Wiring Diagrams. Wiring — Refer to the Label Section on page 181. Maximum Relay Switching — Refer to page 192. 5. Dimensions — Refer to page 187. 6. LEDs provide PLC output ON/OFF indication. Compatibility — To ensure proper operation with the I/O module. 4.120 Digital/Analog Programmable Controller Wiring Systems 1492-XIM20120-16R Relay Master (LED Indicating) 20-Pin Master with Sixteen (16) 120V AC Relays Pinout 1492-XIM2024-16R TB 1 K 16 C N 3 ~ ~ 4 K 17 ~ ~ 5 K 18 ~ ~ 6 K 19 ~ ~ 7 K 20 ~ ~ 8 K 21 ~ ~ 9 K 22 ~ ~ 10 K 23 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 ~ ~ 11 K 24 TB 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 TB 2 ~ ~ Application Notes 1. do not exceed the voltage and current ratings of the XIM. refer to the Wiring System web site information on page 186. Dimensions — Refer to page 187.January 2009 . Wiring — Refer to the Label Section on page 181. Maximum Relay Switching — Refer to page 192. For Field-Side Wiring Diagrams. 12 K1 ~ ~ 13 K2 ~ ~ 14 K3 ~ ~ 15 K4 ~ ~ 16 K5 ~ ~ 17 K6 ~ ~ 18 K7 26 20 19 1 2 25 TB1 1 2 Publication 1492-TD008D-EN-P . 6. Compatibility — To ensure proper operation with the I/O module. LEDs provide PLC output ON/OFF indication. 5. 4. 2. 3. No expansion capability.Digital/Analog Programmable Controller Wiring Systems 121 1492-XIM20120-16RF Relay Master (LED Indicating) 20-Pin Master with Sixteen (16) 120V AC Relays with Fusing Pinout 1492-XIM20120-16RF CN ~ ~ K0 TB1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 TB2 3 ~ ~ 4 K1 ~ ~ 5 K2 ~ ~ 6 K3 ~ ~ 7 K4 ~ ~ 8 K5 ~ ~ 9 K6 ~ ~ K7 10 ~ ~ 11 K0 TB2 ~ ~ Application Notes 1. do not exceed the voltage and current ratings of the XIM. Compatibility — To ensure proper operation with the I/O module. 6. 3. do not exceed the voltage and current ratings of the XIM. 4.January 2009 . With expansion module(s) and cable (included with expansion module) can expand to 32 relays. 5.122 Digital/Analog Programmable Controller Wiring Systems 1492-XIM4024-8R Relay Master (LED Indicating) 40-Pin Master with Eight (8) 24V DC Relays Pinout CN ~ ~ K0 TB A3 3 A4 A5 A6 ~ ~ 4 K1 A7 A8 B3 ~ ~ 5 K2 B4 B5 B6 ~ ~ 6 K3 B7 B8 B9 ~ ~ 7 K4 B10 B11 B12 ~ ~ 8 K5 B13 B14 A9 ~ ~ 9 K6 A10 A11 A12 ~ ~ Application Notes 1. For Field-Side Wiring Diagrams. LEDs provide PLC output ON/OFF indication. Maximum Relay Switching — Refer to page 192. refer to the Wiring System web site information on page 186. 10 K7 A13 A14 20 B16 7 CJ OUT 8 19 1 B15 B1 2 B2 1 CJOUT 2 Publication 1492-TD008D-EN-P . 2. Dimensions — Refer to page 187. Wiring — Refer to the Label Section on page 181. Continued Pinout. Continued CN ~ ~ K0 TB A3 CN 21 23 25 27 29 CJOUT 20 24 28 30 32 31 34 33 5 A4 A5 A6 ~ ~ 7 K1 A7 A8 B3 ~ ~ 9 K2 B4 B5 B6 31 33 35 ~ ~ 11 K3 B7 B8 ~ ~ 13 K4 6 12 11 14 13 16 15 18 17 B9 B10 B11 B12 K5 B13 B14 A9 K6 A10 A11 A12 18 20 8 10 12 14 16 ~ ~ 15 ~ ~ 17 ~ ~ 19 K7 A13 A14 CJOUT 7 8 5 9 10 3 4 6 1 22 24 26 28 30 32 34 36 22 26 19 21 23 25 27 29 37 39 38 40 2 4 1 3 B15 B16 A15 A16 A1 A2 B1 B2 2 Publication 1492-TD008D-EN-P .Digital/Analog Programmable Controller Wiring Systems 123 1492-XIM4024-8R.January 2009 . Wiring — Refer to the Label Section on page 181. 2.124 Digital/Analog Programmable Controller Wiring Systems 1492-XIM4024-16R 1492-RXIM4024-16R Relay Master (LED Indicating) 40-Pin Master with Sixteen (16) 24V DC Relays Application Notes 1. 5. 4. Maximum Relay Switching — Refer to page 192. With expansion module(s) and cable(s) (included with expansion module) can expand to 32 relays. do not exceed the voltage and current ratings of the XIM. Compatibility — To ensure proper operation with the I/O module. refer to the Wiring System web site information on page 186.January 2009 . Dimensions — Refer to page 187. 6. For Field-Side Wiring Diagrams. Publication 1492-TD008D-EN-P . LEDs provide PLC output ON/OFF indication. 3. Pinout Refer to page 125. January 2009 . Continued Pinout.Digital/Analog Programmable Controller Wiring Systems 125 1492-XIM4024-16R 1492-RXIM4024-16R. Continued CN ~ ~ K0 TB1 A3 CN ~ ~ K8 TB2 A3 5 A4 A5 A6 21 A4 A5 A6 ~ ~ 7 K1 ~ ~ 23 K9 A7 A8 B3 A7 A8 B3 ~ ~ 9 K2 ~ ~ 25 K10 B4 B5 B6 B4 B5 B6 ~ ~ 11 K3 ~ ~ 27 K11 B7 B8 B9 B7 B8 B9 29 ~ ~ 13 K4 ~ ~ K12 B10 B11 B12 B10 B11 B12 31 ~ ~ 15 K5 ~ ~ K13 B13 B14 A9 B13 B14 A9 33 ~ ~ 17 K6 ~ ~ K14 A10 A11 A12 A10 A11 A12 35 ~ ~ K15 ~ ~ 19 K7 A13 A14 A13 A14 37 39 38 40 TB2 B1 B2 A1 A2 CJOUT 7 8 5 9 10 TB1 2 4 1 3 A1 A2 B1 B2 3 4 6 1 2 CN 6 8 10 12 14 16 18 20 CJOUT 20 24 28 30 32 31 34 33 22 24 26 28 30 32 34 36 12 11 14 13 16 15 18 17 Publication 1492-TD008D-EN-P . 2. Compatibility — To ensure proper operation with the I/O module. do not exceed the voltage and current ratings of the XIM. 5. Dimensions — Refer to page 187. For Field-Side Wiring Diagrams. 3. 4. 17 K6 22 23 24 ~ ~ K7 19 25 26 ~ ~ 21 CN CJOUT TB2 1 K8 2 3 4 ~ ~ 23 K9 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 20 24 28 30 32 31 34 33 5 6 7 8 9 10 ~ ~ 25 K10 ~ ~ 27 K11 11 12 13 14 15 16 ~ ~ 29 K12 12 11 14 13 16 15 18 17 ~ ~ 31 K13 17 18 19 20 21 22 ~ ~ 33 K14 ~ ~ K15 35 23 24 TB2 CJOUT 37 39 38 40 2 4 1 3 25 26 TB1 7 8 5 9 10 3 4 6 1 2 2 1 Publication 1492-TD008D-EN-P . 6. Wiring — Refer to the Label Section on page 181.126 Digital/Analog Programmable Controller Wiring Systems 1492-XIM4024-16RF Relay Master (LED Indicating) 40-Pin Master with Sixteen (16) 24V DC Relays with Fusing Pinout CN ~ ~ K0 TB1 3 4 5 6 K1 5 ~ ~ 7 7 8 9 10 11 12 ~ ~ 9 K2 ~ ~ 11 K3 13 14 15 ~ ~ 13 K4 16 17 18 ~ ~ 15 K5 19 20 21 ~ ~ Application Notes 1. LEDs provide PLC output ON/OFF indication. refer to the Wiring System web site information on page 186. Maximum Relay Switching — Refer to page 192. With expansion module(s) and cable(s) (included with expansion module) can expand to 32 relays.January 2009 . For Field-Side Wiring Diagrams. 6. 2. 3. Maximum Relay Switching — Refer to page 192. do not exceed the voltage and current ratings of the XIM. Compatibility — To ensure proper operation with the I/O module.January 2009 . LEDs provide PLC output ON/OFF indication. refer to the Wiring System web site information on page 186. 5. Pinout Refer to page 128. 4.Digital/Analog Programmable Controller Wiring Systems 127 1492-XIM24-8R 1492-RXIM24-8R Relay Expander (LED Indicating) with Eight (8) 24V DC Relays Application Notes 1. This relay expander must be used with a 24V DC relay master. Wiring — Refer to the Label Section on page 181. Publication 1492-TD008D-EN-P . Dimensions — Refer to page 187. 128 Digital/Analog Programmable Controller Wiring Systems 1492-XIM24-8R.January 2009 . Continued Pinout. Continued CJIN 16 ~ ~ K0 TB A1 A2 A3 A4 K1 A5 A6 B1 K2 B2 B3 B4 25 26 29 24 23 22 21 20 19 18 A7 K6 A8 A9 A10 17 15 14 13 11 10 9 7 5 31 32 30 CJIN CJOUT 1 2 3 4 6 5 7 8 9 10 20 24 28 30 32 31 34 33 14 12 13 16 11 15 18 17 ~ ~ 12 ~ ~ 8 ~ ~ 6 K3 B5 B6 B7 ~ ~ 4 K4 B8 B9 B10 ~ ~ 3 K5 B11 B12 ~ ~ 2 ~ ~ 1 K7 A11 A12 27 28 Publication 1492-TD008D-EN-P . Continued 1492-RXIM24-8R. LEDs provide PLC output ON/OFF indication. Wiring — Refer to the Label Section on page 181. refer to the Wiring System web site information on page 186. 5.Digital/Analog Programmable Controller Wiring Systems 129 1492-XIM120-8R Relay Expander (LED Indicating) with Eight (8) 120V AC Relays Application Notes 1.January 2009 . Dimensions — Refer to page 187. This relay expander must be used with a 120V AC relay master. For Field-Side Wiring Diagrams. 6. do not exceed the voltage and current ratings of the XIM. Publication 1492-TD008D-EN-P . 3. 4. Pinout Refer to page 130. 2. Compatibility — To ensure proper operation with the I/O module. Maximum Relay Switching — Refer to page 192. Continued Pinout.130 Digital/Analog Programmable Controller Wiring Systems 1492-XIM120-8R. Continued CJIN 16 ~ ~ K0 TB A1 A2 A3 A4 K1 A5 A6 B1 K2 B2 B3 B4 29 24 23 22 21 20 19 18 17 15 A10 K7 A11 A12 13 14 25 26 31 32 30 CJIN CJOUT 1 2 3 4 6 5 7 8 9 10 20 24 28 30 32 31 34 33 14 12 13 16 11 15 18 17 ~ ~ 12 ~ ~ 8 ~ ~ 6 K3 B5 B6 B7 ~ ~ 4 K4 B8 B9 B10 ~ ~ 3 K5 B11 B12 A7 ~ ~ 2 K6 A8 A9 ~ ~ 1 27 28 11 10 9 7 5 Publication 1492-TD008D-EN-P .January 2009 . Digital/Analog Programmable Controller Wiring Systems 131 1492-XIM24-16RF Expander with Sixteen (16) 24V DC Relays with Fusing Pinout 1492-XIM24-16RF CJIN 16 ~ ~ K16 TB1 1 2 3 4 ~ ~ 12 K17 5 6 7 8 9 10 11 12 13 14 15 16 ~ ~ 8 K18 ~ ~ 6 K19 ~ ~ 4 K20 ~ ~ Application Notes 1. Compatibility — To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the XIM. 2. Wiring — Refer to the Label Section on page 181. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 186. 3. This relay expander must be used with a 24 VDC relay master. 4. Dimensions — Refer to page 187. 5. Maximum Relay Switching — Refer to page 192. 6. LEDs provide PLC output ON/OFF indication. 3 K21 17 18 19 ~ ~ 2 K22 20 21 22 ~ ~ K23 1 23 24 TB2 ~ ~ 24 K24 1 2 3 4 ~ ~ 23 K25 5 6 7 8 9 10 11 12 13 14 15 16 ~ ~ 22 K26 ~ ~ 21 K27 ~ ~ 20 K28 ~ ~ 19 K29 17 18 19 ~ ~ 18 K30 20 21 22 ~ ~ K31 17 CJIN 23 24 27 28 Publication 1492-TD008D-EN-P - January 2009 132 Digital/Analog Programmable Controller Wiring Systems 1492-XIMF-F24-2 Fusible 8-Channel Expander with 24V DC Blown Fuse Indicators Application Notes 1. Compatibility — To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the XIM. 2. Wiring — Refer to the Label Section on page 181. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 186. 3. Extra Terminals — Eight field-side terminals are jumpered together on the XIM. For some I/O modules, the terminals are also internally connected to module common through the prewired cable. Refer to the XIM and CABLE pinouts. 4. Dimensions — Refer to page 187. 5. LEDs provide blown fuse indication. Pinout Refer to page 133. Publication 1492-TD008D-EN-P - January 2009 Digital/Analog Programmable Controller Wiring Systems 133 1492-XIMF-F24-2, Continued Pinout, Continued CJIN F8 16 B1 31 32 B2 25 8 5 7 8 9 29 6 10 TB 30 CJIN CJOUT 1 2 3 4 6 12 F9 F10 B3 26 F11 B4 24 20 24 28 30 32 31 34 33 4 F12 23 B5 22 21 3 F13 B6 20 19 2 F14 B7 18 17 1 F15 B8 15 14 A1 A2 13 11 10 9 7 5 13 16 11 15 18 17 14 12 27 28 A3 A4 A5 A6 A7 A8 Publication 1492-TD008D-EN-P - January 2009 4. 2.January 2009 . 3. Wiring — Refer to the Label Section on page 181. Pinout Refer to page 135. Publication 1492-TD008D-EN-P . the terminals are also internally connected to module common through the prewired cable. Extra Terminals — Eight field-side terminals are jumpered together on the XIM. For some I/O modules.134 Digital/Analog Programmable Controller Wiring Systems 1492-XIMF-F120-2 Fusible 8-Channel Expander with 120V AC Blown Fuse Indicators Application Notes 1. 5. LEDs provide blown fuse indication. Refer to the XIM and CABLE pinouts. do not exceed the voltage and current ratings of the XIM. Compatibility — To ensure proper operation with the I/O module. For Field-Side Wiring Diagrams. refer to the Wiring System web site information on page 186. Dimensions — Refer to page 187. Digital/Analog Programmable Controller Wiring Systems 135 1492-XIMF-F120-2.January 2009 . Continued Pinout. Continued CJIN F8 16 B1 31 TB 30 CJIN CJOUT 1 2 3 4 6 12 F9 32 B2 25 8 5 7 8 9 10 F10 B3 26 29 6 F11 B4 24 20 24 28 30 32 31 34 33 4 F12 23 B5 22 21 B6 20 19 3 F13 2 F14 B7 18 17 1 F15 B8 15 14 13 11 10 9 7 5 14 12 13 16 11 15 18 17 A1 A2 27 28 A3 A4 A5 A6 A7 A8 Publication 1492-TD008D-EN-P . Extra Terminals — Eight field-side terminals are jumpered together on the XIM. Compatibility — To ensure proper operation with the I/O module.January 2009 . the terminals are also internally connected to module common through the prewired cable. refer to the Wiring System web site information on page 186. Refer to the XIM and CABLE pinouts.136 Digital/Analog Programmable Controller Wiring Systems 1492-XIMF-2 Expander with Eight (8) Feed-Through Channels Application Notes 1. 2. Publication 1492-TD008D-EN-P . 4. 3. For some I/O modules. Dimensions — Refer to page 187. do not exceed the voltage and current ratings of the XIM. Pinout Refer to page 137. Wiring — Refer to the Label Section on page 181. For Field-Side Wiring Diagrams. Digital/Analog Programmable Controller Wiring Systems 137 1492-XIMF-2.January 2009 . Continued CJIN 16 TB 30 B1 31 32 CJIN CJOUT 1 2 3 4 6 12 B2 25 5 7 8 9 29 10 8 B3 26 6 B4 24 23 20 24 28 30 32 31 34 33 4 B5 22 21 3 B6 20 19 2 B7 18 17 1 B8 15 14 A1 A2 13 11 10 9 7 5 13 16 11 15 18 17 14 12 27 28 A3 A4 A5 A6 A7 A8 Publication 1492-TD008D-EN-P . Continued Pinout. when used with an IFM or XIM. The digital ready-to-wire cables provide one end of the cable pre-terminated.and 32-point Bulletin 1746. and 1771 digital I/O modules. or 1771 Wiring Arm on one end and a cable connector on the other to connect to the IFM or XIM. Pre-Wired Cables Specifications The pre-wired cables have a Bulletin 1746 Removable Terminal Block. 1769 Removable Terminal Block.January 2009 . for either an IFM (IFM-ready cable) or a programmable controller I/O module (I/O module-ready cable). Digital pre-wired cables. Publication 1492-TD008D-EN-P . replace the point-to-point wiring between Allen-Bradley programmable controller I/O modules and individual terminal blocks. 1756. 1756 Removable Terminal Block. 1769. The broad offering of digital pre-wired cables supports over 100 different 16.138 Digital/Analog Programmable Controller Wiring Systems Digital Cable Specifications Bulletin 1492 pre-wired cables are designed to minimize control wiring in a panel. 1794. 2. 5.0.0.5. 2.5.5.36 in. 5.5. 1. 2.0.7 mm (0. 1.5. 5.0. 1.5.) 9.0 mm (0. Continued No. 2.5.5. 2.) 9. 2.36 in.7 mm (0.) 9. 5.5. 5.0 m 0. 2. 2. 1.5.) 9. 1.36 in. 1.0 m 0.0 mm (0. 2. 2.36 in.0 m 0.5.46 in.0 mm (0.0 mm (0. 1.5. 1. 2.46 in.5.0 m 0.36 in.5.5. 1. 5.0 mm (0. 5.0 m 0.0.0 m 0.) 9. 2.5. 2.0.0.0 m 0.5.5.) 11.5.5.0 mm (0.0 mm (0.0.5.46 in. 1.5.0.0.5.) 9. -24BWA Output Terminal 1764-28BXB Output Terminal 1769-RTBN18 Removable Terminal Block 1769-RTBN18 Removable Terminal Block 1769-RTBN10 Removable Terminal Block 1769-RTBN18 Removable Terminal Block 1769-RTBN18 Removable Terminal Block 1769-RTBN18 Removable Terminal Block 1769-RTBN18 Removable Terminal Block 1769-RTBN18 Removable Terminal Block Publication 1492-TD008D-EN-P . 5.0.) 11.0 m 0. 2.0 mm (0.) 9. 1. 5.0. 5.5.) 9. 2.0 mm (0.0 mm (0.0 mm (0.5.) 9.0 mm (0. 1.0.46 in.36 in.5.) 9.5.0.5. 1. 5.0 m 0.) 9. 1.0 mm (0. 5. 2.0 m 0.5.36 in.0. 1.36 in.0 m 0. 1.0 m 0. 5.) 9.0 m 0.0.5.36 in.36 in.5. 1. 5.7 mm (0.5.0 m 0.0 mm (0.) 9.5. 1.0 m 0.) 11.7 mm (0.36 in.) 9.0 m 0. 2. 1. 5.7 mm (0.5.5. 2. 2.0.5.46 in.0 m 0. 2.5.36 in.0 m 0.0 m Insulation Rating 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C Pre-Wired Cables.0. 5.5.) 11.0 m 0.5.0. 1.0 m 0.5.) 11.0.0 m 0.0.36 in.) 9. 1.) 9.0 mm (0.5.0 mm (0.5.0 m 0.) 9.36 in.5. 2.) 11.36 in. 5.5.5. 2.) 9.5.0 mm (0.36 in.36 in. 1. 1.5. 2.0.) 11.5.Digital/Analog Programmable Controller Wiring Systems 139 Digital Cable Specifications.0 m 0.5. 2.0 m 0.5.0 m 0.5.5.36 in. 5. 2.0 mm (0.36 in.5.7 mm (0.7 mm (0.0.5. 2. 1.0.0 m 0.46 in. 5.0.0 m 0.36 in. 5. 5.0 mm (0. 2. 1.) 9. 1.36 in.0.7 mm (0. 2.0.7 mm (0.0 mm (0.0 mm (0.5.5. 1. 1. 1. 5. 1.January 2009 .5.46 in.0.7 mm (0.7 mm (0. 1.0.36 in. -24BWA Input Terminal 1764-28BXB Input Terminal 1764-24AWA.0 mm (0. 2.) 9.5. 5.5.) 11.0 mm (0.0. 5.5. 2. 1.36 in.0. 1.46 in.0 mm (0.0 m 0.) 11.) 11.0 mm (0.0 mm (0. 5. 5.5. 2.5.0 mm (0.0 m 0.46 in.0 m 0.5.) 9.5.5.46 in. 2. 5. 2.5.0.5.) I/O Module Connector 1746-RT25R Red Removable Terminal Block 1746-RT25B Blue Removable Terminal Block 1746-RT25R Red Removable Terminal Block 1746-RT25R Red Removable Terminal Block 1746-RT25C Orange Removable Terminal Block 1746-RT25B Blue Removable Terminal Block 1771-WH (16-Point/21 Terminal) Wiring Arm 1771-WHF (16-Point/21 Terminal) Fused Wiring Arm 1746-RT25R Red Removable Terminal Block 1746-N3 40-Pin Cable Connector 1771-WN (32-Point/40 Terminal) Wiring Arm 1771-WN (32-Point/40 Terminal) Wiring Arm 1771-WN (32-Point/40 Terminal) Wiring Arm 1771-WN (32-Point/40 Terminal) Wiring Arm 1746-RT25C Orange Removable Terminal Block 1771-WN (32-Point/40 Terminal) Wiring Arm 1771-WN (32-Point/40 Terminal) Wiring Arm 1746-RT25C Orange Removable Terminal Block 1771-WA (8-Point/10 Terminal) Wiring Arm 1756-TBNH Removable Terminal Block 1756-TBNH Removable Terminal Block 1756-TBNH Removable Terminal Block 1756-TBNH Removable Terminal Block 1756-TBCH Removable Terminal Block 1756-TBCH Removable Terminal Block 1762-L40xxx Input Terminal 1762-L40xxx Output Terminal 1764-24AWA. 1.) 9.) 9.0 m 0.) 9.5. 2.5.5.7 mm (0.5.0 m 0. 5.0.0.0.) 11.5.0.5. 1.) 9. 1.5. 5.5. 5. 5. 2.5. Continued Digital Pre-Wired Cable Specifications Catalog Number 1492-CABLE➊A 1492-CABLE➊B 1492-CABLE➊C 1492-CABLE➊CR 1492-CABLE➊D 1492-CABLE➊E 1492-CABLE➊F 1492-CABLE➊FF 1492-CABLE➊G 1492-CABLE➊H 1492-CABLE➊J 1492-CABLE➊K 1492-CABLE➊L 1492-CABLE➊M 1492-CABLE➊N 1492-CABLE➊R 1492-CAB➊R71 1492-CABLE➊S 1492-CABLE➊T 1492-CABLE➊U 1492-CABLE➊V 1492-CABLE➊W 1492-CABLE➊X 1492-CABLE➊Y 1492-CABLE➊Z 1492-CAB➊A62 1492-CAB➊B62 1492-CAB➊A64 1492-CAB➊B64 1492-CAB➊C64 1492-CAB➊F64 1492-CAB➊A69 1492-CAB➊B69 1492-CAB➊C69 1492-CAB➊D69 1492-CAB➊E69 1492-CAB➊F69 1492-CAB➊G69 1492-CAB➊H69 Standard Cable Lengths 0.0 m 0. 1.46 in. 5. 5.36 in.0. 5. 1. 1. 2.) 11.46 in.0 m 0. 2.0. 5. 5.36 in. 5.36 in.0 m 0.0 m 0.36 in. 5.0 m 0. 2. of Conductors 20 20 20 20 20 20 20 20 20 40 40 40 40 40 20 40 40 20 20 20 20 20 20 40 40 40 40 20 20 20 20 20 20 20 20 20 20 20 20 Conductor Size #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG Nominal Outer Diameter 9. 5.5.0 m 0. 2.) 9.0.5. 46 in.46 in. 5.0 m 0. 1.5.0 m).1 mm (0. Example: Catalog Number 1492-CABLE005A is for a 0. 1.) 11.0 m 0.0 m.36 in.0 m 0.0.0 mm (0.5.) 11.5.0.0. 5. To order.0 mm (0. 2. 010 = 1.0. 5.0. 5. 5.) 9. 2.5. 5. 1.36 in. 2.0 m Insulation Rating 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C No.0. 2. 2.) 9.0.5.0 mm (0.0 m.5 m.5.5. 2.5.5.0 m 0.5.0 mm (0.36 in. 1.) 9.5 m cable for the 1746-IA16 I/O Module. 1.5.5. 1.36 in. and 050 = 5.5.5 m. 025 = 2. and 5.5 m. insert the code for the desired cable length into the catalog number (005 = 0. Also refer to Build-to-Order Length Cables on page 65.0.) 9. 2.0 m. 1.36 in. 5.5 m.0 m 0.0. 1. 5. 2.46 in.7 mm (0.) 9.0 m 0.5.5.1 mm (0.5.0 m 0. 1. 1. ➋ Mates with 1794 Flex D-shell style base: 1794-TB37DS ➌ Mates with 1794 Flex D-shell style base: 1794-TB62DS Publication 1492-TD008D-EN-P .140 Digital/Analog Programmable Controller Wiring Systems Digital Pre-Wired Cable Specifications (Continued) Catalog Number 1492-CAB➊J69 1492-CAB➊K69 1492-CAB➊L69 1492-CAB➊M69 1492-CAB➊A7H 1492-CAB➊A7S 1492-CAB➊B7H 1492-CAB➊A94 1492-CAB➊B94 Standard Cable Lengths 0.5. 5.0 m 0.0 mm (0. of Conductors 40 40 20 20 20 20 20 20 40 Conductor Size #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG Nominal Outer Diameter 11.) 9.0 mm (0.January 2009 .5.) I/O Module Connector (2) 1769-RTBN18 Removable Terminal Block (2) 1769-RTBN18 Removable Terminal Block 1769-RTBN18 Removable Terminal Block 1769-RTBN18 Removable Terminal Block 20C-DA1-A and 20C-D01 Terminals 20C-DB1-A and 20C-D01 Terminals TB2 37-Pin male D-shell ➋ 62-Pin male D-shell ➌ ➊ Cables are available in standard lengths of 0.36 in. 2. 2. 1794TB37DS or 1794-62DS). The description listed first is the wire color of the conductor connected to the PLC or PowerFlex drive removable terminal block (Bulletin 1746. The number that follows in parentheses is the corresponding pin number of the IFM/XIM mating connector. Shield Base Color Stripe Color Blue (24) NC Black (23) White/Green (22) 20 or 40 Connector Pin Number White/Red (19) No Connection Twisted Pair Individual Conductor Jumper Wire I/O Pin Connector Definition 1 19 39 1 20 2 2 40 20-Conductor Cable 40-Conductor Cable IFM Mating Connector Definition Publication 1492-TD008D-EN-P .Digital/Analog Programmable Controller Wiring Systems 141 Digital Cable Specifications.January 2009 . 1764. 1762. 700S and 700H I/O) wiring arm (1771 I/O) or D-shell connector (Cat. No. 1756. 1769. Continued Pinouts Digital/Analog Programmable Controller Wiring Systems Digital Pre-Wired Cables The following diagrams illustrate how the individual conductors in the digital pre-wired cables are terminated at both ends. Continued Digital/Analog Programmable Controller Wiring Systems Red RTB Green (4) Blue (6) Red/Black (8) Orange/Black (10) Black/White (12) Green/White (14) Black/Red (16) Orange/Red (18) Red/Green (20) Red (3) Orange (5) White/Black (7) Green/Black (9) Blue/Black (11) Red/White (13) Blue/White (15) White/Red (17) Blue/Red (19) 1 3 5 7 9 11 13 15 17 2 4 6 8 10 12 14 16 18 Blue RTB Green (4) Blue (6) Red/Black (8) Orange/Black (10) Black/White (12) Green/White (14) Black/Red (16) Orange/Red (18) Red/Green (20) 1492-CABLE➊A 1492-CABLE➊B White (2) Black (1) Green (4) Blue (6) Red/Black (8) Orange/Black (10) Black/White (12) Green/White (14) Black/Red (16) Orange/Red (18) 1 3 5 7 9 11 13 15 17 2 4 6 8 10 12 14 16 18 Red RTB White (2) Black (1) Red (3) Green (4) Orange (5) Blue (6) White/Black (7) Red/Black (8) Green/Black (9) Blue/Red (19) Orange/Black (10) Red/Green (20) Black/White (12) Blue/Black (11) Green/White (14) Red/White (13) Black/Red (16) Blue/White (15) Orange/Red (18) White/Red (17) 1 3 5 7 9 11 13 15 17 2 4 6 8 10 12 14 16 18 White (2) Orange RTB Black (1) Red (3) Green (4) Orange (5) Blue (6) White/Black (7) Red/Black (8) Green/Black (9) Blue/Red (19) Orange/Black (10) Red/Green (20) Black/White (12) Blue/Black (11) Green/White (14) Red/White (13) Black/Red (16) Blue/White (15) Orange/Red (18) White/Red (17) Blue RTB 1 3 5 7 9 11 13 15 17 2 4 6 8 10 12 14 16 18 Red (3) Orange (5) White/Black (7) Green/Black (9) Blue/Black (11) Red/White (13) Blue/White (15) White/Red (17) Blue/Red (20) Red/Green (19) 1492-CABLE➊C 1492-CABLE➊D 1492-CABLE➊E A B C D 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 E Black (1) White (2) Blue/Red (19) Red (3) Green (4) Orange (5) Blue (6) White/Black (7) Red/Black (8) Green/Black (9) Orange/Black (10) Blue/Black (11) Black/White (12) Red/White (13) Green/White (14) Blue/White (15) Black/Red (16) White/Red (17) Orange/Red (18) Red/Green (20) CAUTION DISCONNECT POWER BEFORE SERVICING FUSES ALL FUSES 30-250V A B C D 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 E Black (1) White (2) Blue/Red (19) Red (3) Green (4) Orange (5) Blue (6) White/Black (7) White (2) Red/Black (8) Black (1) Green/Black (9) Green (4) Orange/Black (10) Blue (6) Blue/Black (11) Red/Black (8) Black/White (12) Red/White (13) Orange/Black (10) Green/White (14) Black/White (12) Blue/White (15) Green/White (14) Black/Red (16) Black/Red (16) White/Red (17) Orange/Red (18) Orange/Red (18) Red/Green (20) Jumper Red RTB 1 3 5 7 9 11 13 15 17 2 4 6 8 10 12 14 16 18 Red (3) Orange (5) White/Black (7) Green/Black (9) Blue/Red (19) Blue/Black (11) Red/White (13) Blue/White (15) White/Red (17) 1492-CABLE➊F 1492-CABLE➊FF ➊ Refer to footnote on page 149.142 Digital/Analog Programmable Controller Wiring Systems Digital Cable Specifications. Continued Red (3) Orange (5) White/Black (7) Green/Black (9) Blue/Black (11) Red/White (13) Blue/White (15) White/Red (17) Blue/Red (19) 1 3 5 7 9 11 13 15 17 2 4 6 8 10 12 14 16 18 Pinouts. 1492-CABLE➊G Publication 1492-TD008D-EN-P -January 2009 . Publication 1492-TD008D-EN-P -January 2009 . refer to the table on page 151 and match the wire color to the IFM Pin reference number. Continued White/Black (7) Blue/Black (11) Blue/White (15) Blue/Red (19) Red (3) White/Black-Red (23) Blue/Black-White (27) Green/Black-Orange (31) White/Red-Orange (35) White/Black-Green (39) Red/Black (8) Black/White (12) Black/Red (16) Red/Green (20) Green (4) Red/Black-White (24) Black/Red-Green (28) Orange/Black-Green (32) Orange/White-Blue (36) Red/White-Green (40) 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 Pinouts. Continued Orange (5) Green/Black (9) Red/White (13) White/Red (17) Black (1) Orange/Green (21) Green/Black-White (25) White/Red-Green (29) Blue/White-Orange (33) White/Red-Blue (37) Blue (6) Orange/Black (10) Green/White (14) Orange/Red (18) White (2) Black/White-Red (22) Orange/Black-White (26) Red/Black-Green (30) Black/White-Orange (34) Black/White-Green (38) Red (3) White/Black (7) Blue/Black (11) Blue/White (15) Blue/Red (19) White/Black-Green (39) White/Black-Red (23) Blue/Black-White (27) Green/Black-Orange (31) White/Red-Orange (35) Green (4) Red/Black (8) Black/White (12) Black/Red (16) Red/Green (20) Red/White-Green (40) Red/Black-White (24) Black/Red-Green (28) Orange/Black-Green (32) Orange/White-Blue (36) 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 Black (1) Orange (5) Green/Black (9) Red/White (13) White/Red (17) White/Red-Blue (37) Orange/Green (21) Green/Black-White (25) White/Red-Green (29) Blue/White-Orange (33) White (2) Blue (6) Orange/Black (10) Green/White (14) Orange/Red (18) Black/White-Green (38) Black/White-Red (22) Orange/Black-White (26) Red/Black-Green (30) Black/White-Orange (34) 1492-CABLE➊J Orange (5) Green/Black (9) Red/White (13) White/Red (17) White/Red-Blue (37) Orange/Green (21) Green/Black-White (25) White/Red-Green (29) Blue/White-Orange (33) Black (1) ➋ White (2) White/Black-Green (39) Red (3) Blue (6) Green (4) Orange/Black (10) Orange (5) Green/White (14) Blue (6) Orange/Red (18) White/Black (7) Black/White-Green (38) Red/Black (8) Black/White-Red (22) Green/Black (9) Orange/Black (10) Orange/Black-White (26) Red/Black-Green (30) Blue/Black (11) Black/White (12) Black/White-Orange (34) Red/White (13) Red/White-Green (40) Green/White (14) Blue/White (15) Black/Red (16) White/Red (17) Orange/Red (18) Blue/Red (19) Red/Green (20) Orange/Green (21) Black/White-Red (22) White/Black-Red (23) Red/Black-White (24) Green/Black-White (25) Orange/Black-White (26) Blue/Black-White (27) Black/Red-Green (28) White/Red-Green (29) Red/Black-Green (30) Green/Black-Orange (31) Orange/Black-Green (32) Blue/White-Orange (33) Black/White-Orange (34) White/Red-Orange (35) Orange/White-Blue (36) White/Red-Blue (37) Black/White-Green (38) White/Black-Green (39) Red/White-Green (40) 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 1492-CABLE➊K Black (1) White/Black (7) Blue/Black (11) Blue/White (15) Blue/Red (19) Red (3) White/Black-Red (23) Blue/Black-White (27) Green/Black-Orange (31) White/Red-Orange (35) White (2) Red/Black (8) Black/White (12) Black/Red (16) Red/Green (20) Green (4) Red/Black-White (24) Black/Red-Green (28) Orange/Black-Green (32) Orange/White-Blue (36) 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 1 2 1492-CABLE➊L 39 40 1492-CABLE➊H Orange (5) White/Black (7) Green/Black (9) Blue/Black (11) NC Red/White (13) Blue/White (15) White/Red (17) Blue/Red (19) NC Orange/Green (21) White/Black-Red (23) Green/Black-White (25) Blue/Black-White (27) NC White/Red-Green (29) Green/Black-Orange (31) Blue/White-Orange (33) White/Red-Orange (35) NC 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 Blue (6) Red/Black (8) Orange/Black (10) Black/White (12) NC Green/White (14) Black/Red (16) Orange/Red (18) Red/Green (20) NC Black/White-Red (22) Red/Black-White (24) Orange/Black-White (26) Black/Red-Green (28) NC Red/Black-Green (30) Orange/Black-Green (32) Black/White-Orange (34) Orange/White-Blue (36) NC 1492-CABLE➊M ➊ Refer to footnote on page 149.Digital/Analog Programmable Controller Wiring Systems 143 Digital Cable Specifications. For the IFM end reference. ➋ Connector Pin reference. Continued Pinouts. Continued Black (1) White (2) Green (4) Blue (6) Red/Black (8) Orange/Black (10) Black/White (12) Green/White (14) Black/Red (16) Orange/Red (18) Jumper Orange RTB 1 3 5 7 9 11 13 15 17 A 2 4 6 8 10 12 14 16 18 Red (3) Orange (5) White/Black (7) Green/Black (9) Blue/Red (19) Blue/Black (11) Red/White (13) Blue/White (15) White/Red (17) 0 1 2 3 4 5 6 7 B White (2) Blue/Red (19) Red (3) Green (4) Orange (5) Blue (6) Blue/White (15) Black/Red (16) White/Red (17) Orange/Red (18) White/Black (7) Blue/Black (11) Black (1) White/Black (7) Red/Black (8) Green/Black (9) Orange/Black (10) Blue/Black (11) Black/White (12) Red/White (13) Green/White (14) Red/Green (20) 2 4 6 8 1 3 5 7 10 9 12 11 14 13 16 15 18 17 20 19 White (2) Red (3) Green (4) Orange (5) Blue (6) Blue/White (15) Black/Red (16) White/Red (17) Orange/Red (18) Blue/Red (19) 1492-CABLE➊N 1492-CABLE➊T 1492-CABLE➊U Red (3) White/Black (7) Blue/Black (11) Blue/White (15) Blue/Red (19) White/Black-Red (23) Blue/Black-White (27) Green/Black-Orange (31) White/Red-Orange (35) White/Black-Green (39) Green (4) Red/Black (8) Black/White (12) Black/Red (16) Red/Green (20) Red/Black-White (24) Black/Red-Green (28) Orange/Black-Green (32) Orange/White-Blue (36) Red/White-Green (40) 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 Black (1) Orange (5) Green/Black (9) Red/White (13) White/Red (17) Orange/Green (21) Green/Black-White (25) White/Red-Green (29) Blue/White-Orange (33) White/Red-Blue (37) White (2) Blue (6) Orange/Black (10) Green/White (14) Orange/Red (18) Black/White-Red (22) Orange/Black-White (26) Red/Black-Green (30) Black/White-Orange (34) Black/White-Green (38) Orange (5) White/Black (7) Green/Black (9) Blue/Black (11) Red/White (13) Blue/White (15) White/Red (17) Blue/Red (19) Black/White-Red (22) NC White/Black-Red (23) Orange/Black-White (26) NC Blue/Black-White (27) Red/Black-Green (30) NC Green/Black-Orange (31) Black/White-Orange (34) NC White/Red-Orange (35) 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 Blue (6) Red/Black (8) Orange/Black (10) Black/White (12) Green/White (14) Black/Red (16) Orange/Red (18) Red/Green (20) NC Orange/Green (21) Red/Black-White (24) NC Green/Black-White (25) Black/Red-Green (28) NC White/Red-Green (29) Orange/Black-Green (32) NC Blue/White-Orange (33) Orange/White-Blue (36) 1492-CABLE➊R NC White (2) Green (4) Blue (6) Red/Black (8) Black/White (12) Green/White (14) Black/Red (16) Orange/Red (18) NC 2 4 6 8 1 3 5 7 1492-CAB➊R71 Black (1) Red (3) Orange (5) White/Black (7) Green/Black (9) Blue/Black (11) Red/White (13) Blue/White (15) White/Red (17) Blue/Red (19) 10 9 12 11 14 13 16 15 18 17 20 19 White (2) Green (4) Blue (6) Red/Black (8) NC Black/White (12) Green/White (14) Black/Red (16) Orange/Red (18) 1 3 5 7 9 11 13 15 17 Orange RTB 2 4 6 8 10 12 14 16 18 Red (3) Orange (5) White/Black (7) Green/Black (9) NC Blue/Black (11) Red/White (13) Blue/White (15) White/Red (17) 1492-CABLE➊V White (2) Green (4) Blue (6) Red/Black (8) Orange/Black (10) Black/White (12) Green/White (14) Black/Red (16) Orange/Red (18) Red/Green (20) 2 4 6 8 1 3 5 7 10 9 12 11 14 13 16 15 18 17 20 19 Red (3) Orange (5) White/Black (7) Green/Black (9) Black (1) Blue/Black (11) Red/White (13) Blue/White (15) White/Red (17) Blue/Red (19) 1492-CABLE➊S ➊ Refer to footnote on page 149. 1492-CABLE➊W Publication 1492-TD008D-EN-P -January 2009 .144 Digital/Analog Programmable Controller Wiring Systems Digital Cable Specifications. Continued Green (4) Blue (6) Red/Black (8) Orange/Black (10) Black (1) Black/White (12) Green/White (14) Black/Red (16) Orange/Red (18) Blue/Red (19) 2 4 6 8 1 3 5 7 Red (3) Orange (5) White/Black (7) Green/Black (9) White (2) Blue/Black (11) Red/White (13) Blue/White (15) White/Red (17) Red/Green (20) 10 9 12 11 14 13 16 15 18 17 20 19 Orange (5) White/Black (7) Green/Black (9) Blue/Black (11) Red/White (13) Blue/White (15) White/Red (17) Blue/Red (19) Orange/Green (21) White/Black-Red (23) Green/Black-White (25) Blue/Black-White (27) White/Red-Green (29) Green/Black-Orange (31) Blue/White-Orange (33) White/Red-Orange (35) NC NC 2 4 6 8 1 3 5 7 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 30 29 32 31 34 33 36 35 Blue (6) Red/Black (8) Orange/Black (10) Black/White (12) Green/White (14) Black/Red (16) Orange/Red (18) Red/Green (20) Black/White-Red (22) Red/Black-White (24) Orange/Black-White (26) Black/Red-Green (28) Red/Black-Green (30) Orange/Black-Green (32) Black/White-Orange (34) Orange/White-Blue (36) NC NC 1492-CABLE➊X White/Black (7) Blue/Black (11) Blue/White (15) Blue/Red (19) White/Black-Red (23) Blue/Black-White (27) Green/Black-Orange (31) Black (1) White/Red-Orange(35) Red(3) Red/Black (8) Black/White (12) Black/Red (16) Red/Green (20) Red/Black-White (24) Black/Red-Green (28) Orange/Black-Green (32) Orange/White-Blue (36) White (2) Green (4) Orange (5) Green/Black (9) Red/White (13) White/Red (17) Orange/Green (21) Green/Black-White (25) White/Red-Green (29) Blue/White-Orange (33) White/Black-Green (39) White/Red-Blue (37) Blue (6) Orange/Black (10) Green/White (14) Orange/Red (18) Black/White-Red (22) Orange/Black-White (26) Red/Black-Green (30) Black/White-Orange (34) Red/White-Green (40) Black/White/Green (38) 1492-CABLE➊Y 2 4 6 8 1 3 5 7 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 30 29 32 31 34 33 36 35 Black (1) White (2) Green (4) Blue (6) Red/Black (8) Orange/Black (10) Black/White (12) Green/White (14) Black/Red (16) Orange/Red (18) 1 3 5 7 9 11 13 15 17 2 4 6 8 10 12 14 16 18 Red (3) Orange (5) White/Black (7) Green/Black (9) Blue/Red (19) Blue/Black (11) Red/White (13) Blue/White (15) White/Red (17) 1492-CABLE➊CR (Red RTB) 1492-CABLE➊Z Green/Black/Orange (31) Blue/Black/White (27) Orange/Black/White (26) White/Black/Red (23) White/Red/Blue (37) Black/White/Green (38) White/Red (17) Red/White (13) Blue/Black (11) White/Black (7) Black (1) White (2) Red/Black (8) White/Red/Orange (35) Red/Green (20) Black/White (12) Black/Red (16) (High Row) Row B Row A (High Row) Row B 1 1 (Low Row) 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 10 11 12 13 14 15 9 10 11 12 13 14 1 (Low Row) 2 1 2 3 3 4 4 5 5 6 6 7 7 8 8 9 10 11 12 13 9 10 11 12 Row A Black/White (12) Black/Red/Green (28) Orange/Black/Green (32) Orange/Black (10) Blue (6) Blue/White/Orange (33) 1492-CAB➊A62 ➊ Refer to footnote on page 149. Green/Black/White (25) 1492-CAB➊B62 Publication 1492-TD008D-EN-P -January 2009 Black/White/Orange (34) White/Red/Green (29) Black/White/Green (38) Black/Red (16) Black (1) Red (3) Red/Green (20) Red/Black/White (24) White (2) Green/White (14) Orange/Green (21) Orange/Red (18) Blue/Red (19) Blue/White (15) Red (3) Green (4) Green/Black (9) Orange (5) Green (4) White/Red/Blue (37) White/Black/Green (39) Orange/White/Blue (36) Red/White/Green (40) Red/Black/Green (30) Black/White/Red (22) Orange/Black (10) Green/White (14) Orange/Red (18) Red/Black (8) Blue (6) . Continued Pinouts.Digital/Analog Programmable Controller Wiring Systems 145 Digital Cable Specifications. 1492-CAB➊G69 1492-CAB➊H69 Publication 1492-TD008D-EN-P -January 2009 Green/White (14) Red (3) Green (4) Green/Black (9) . Continued White/Red (17) Red/White (13) Blue/Black (11) Orange/Black (10) Red/Black (8) Blue/White (15) White (2) 7 8 Orange (5) 8 (High Row) Row B 1 (Low Row) 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 (High Row) Row B 1 1 2 2 3 3 4 4 5 5 6 6 7 Row A 1 (Low Row) Row A 9 10 11 Orange/Red (18) Green/White (14) Black/White (12) Blue/Red (19) Red/Green (20) Green/Black (9) Black/Red (16) Green/White (14) White (2) Blue/White (15) Black/Red (16) White/Red (17) Orange/Red (18) Red/Black (8) Orange/Black (10) Black/White (12) Blue/Red (19) Red/Green (20) Green/Black (9) White/Black (7) Blue (6) Green (4) Blue/Black (11) Red/White (13) White/Black (7) Blue (6) Green (4) Black (1) Black (1) Red (3) 9 10 Orange/Black (10) 7 8 1492-CAB➊A64 (High Row) Row B Row A 1492-CAB➊B64 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 10 9 10 11 (Low Row) (High Row) Row B Row A 1 2 2 3 3 4 4 5 5 6 6 7 8 (Low Row) 1 9 10 11 Blue/Red (19) Red/Green (20) Black/White (12) Orange (5) Blue (6) Red (3) Green (4) Green/White (14) Green/Black (9) White/Black (7) White/Red (17) Orange/Red (18) Orange (5) White/Black (7) Blue/Black (11) Red/Green (20) Black/White (12) Red/White (13) 9 10 Black (1) White (2) Blue/White (15) Black/Red (16) Blue (6) Red/Black (8) Blue/Red (19) Black (1) 1492-CAB➊C64 1492-CAB➊F64 Green (4) Blue (6) Red/Black (8) Orange/Black (10) Black/White (12) Green/White (14) Black/Red (16) Orange/Red (18) Blue/Red (19) Red/Green (20) 2 4 6 8 10 12 14 16 18 1 3 5 7 9 11 13 15 17 Red (3) Orange (5) White/Black (7) Green/Black (9) Blue/Black (11) Red/White (13) Blue/White (15) White/Red (17) Black (1) White (2) Green (4) Blue (6) Red/Black (8) Orange/Black (10) Black/White (12) Green/White (14) Black/Red (16) Orange/Red (18) Blue/Red (19) Red/Green (20) 2 4 6 8 10 12 14 16 18 1 3 5 7 9 11 13 15 17 Red (3) Orange (5) White/Black (7) Green/Black (9) Black (1) White (2) Blue/Black (11) Red/White (13) Blue/White (15) White/Red (17) Red (3) White/Black (7) Blue/Red (19) Red/Green (20) Blue/Black (11) Blue/White (15) 6 8 10 12 14 5 7 9 11 13 Orange/Black (10) Black (1) Orange (5) Green/Black (9) Red/White (13) White/Red (17) 1492-CAB➊A69 Red (3) Orange (5) White/Black (7) Green/Black (9) Blue/Black (11) Red/White (13) Blue/White (15) White/Red (17) NC 2 4 6 8 10 12 14 16 18 1 3 5 7 9 11 13 15 17 1492-CAB➊B69 White (2) Green (4) Blue (6) Red/Black (8) Black/White (12) Green/White (14) Black/Red (16) Orange/Red (18) NC 1492-CAB➊C69 Black (1) White (2) Green (4) Blue (6) Red/Black (8) Orange/Black (10) Black/White (12) Green/White (14) Black/Red (16) Orange/Red (18) Red (3) Orange (5) White/Black (7) Green/Black (9) Blue/Black (11) Red/White (13) Blue/White (15) White/Red (17) Blue/Red (19) Red/Green (20) 2 4 6 8 10 12 14 16 18 1 3 5 7 9 11 13 15 17 1492-CAB➊D69 1492-CAB➊E69 White (1) Black (2) Green (4) Blue (6) Red/Black (8) Orange/Black (10) Black/White (12) Green/White (14) Black/Red (16) Orange/Red (18) Green (4) Blue (6) Red/Black (8) Orange/Black (10) Black/White (12) Green/White (14) Black/Red (16) Orange/Red (18) NC 2 4 6 8 10 12 14 16 18 1 3 5 7 9 11 13 15 17 Red (3) Orange (5) White/Black (7) Green/Black (9) Blue/Black (11) Red/White (13) Blue/White (15) White/Red (17) NC Green (4) Blue (6) Red/Black (8) Orange/Black (10) Black/White (12) Green/White (14) NC NC Red/Green (20) 2 4 6 8 10 12 14 16 18 1 3 5 7 9 11 13 15 17 Red (3) Orange (5) White/Black (7) Green/Black (9) Blue/Black (11) Red/White (13) NC NC Blue/Red (19) Red (3) Orange (5) White/Black (7) Green/Black (9) Blue/Red(19) Blue/Black (11) Red/White(13) Blue/White(15) White/Red (17) 2 4 6 8 10 12 14 16 18 1 3 5 7 9 11 13 15 17 1492-CAB➊F69 ➊ Refer to footnote on page 149.146 Digital/Analog Programmable Controller Wiring Systems Digital Cable Specifications. Continued Orange/Black (10) Red/Black (8) White (2) Orange (5) Red/White (13) Blue/Black (11) Red (3) Pinouts. ➋ 1492-CAB➊K69 and 1492-CAB➊J69 are made up of two (2) individual 18-pin terminal blocks connected to a single cable assembly. Continued R Orange (5) Green/Black (9) Red/White (13) White/Red (17) White/Black/Green (39) White/Red/Blue (37) Orange/Green (21) Red/Black (8) Black/White (12) Black/Red (16) Red/Green (20) Red/Black/White (24) 2 4 6 8 10 12 14 16 18 1 3 5 7 9 11 13 15 17 White/Black (7) Blue/Black (11) Blue/White (15) Blue/Red (19) White/Black/Red (23) Blue/Black/White (27) Green/Black/Orange (31) White/Red/Orange (35) Black (1) Red (3) 2 4 6 8 10 12 14 16 18 Blue (6) Orange/Black (10) Green/White (14) Orange/Red (18) Black/White/Green (38) Red/White/Green (40) Black/White/Red (22) Orange/Black/White (26) Red/Black/Green (30) Black/White/Orange (34) 3 5 7 9 11 13 15 17 Green/Black/White (25) Black/Red/Green (28) White/Red/Green (29) Orange/Black/Green (32) Blue/White/Orange (33) Orange/White/Blue (36) White (2) Green (4) 1492-CAB➊J69 ➋ L Orange (5) Green/Black (9) Red/White (13) White/Red (17) Orange/Green (21) Green/Black/White (25) White/Red/Green (29) Blue/White/Orange (33) White/Black/Green (39) White/Red/Blue (37) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 R Red (3) Black (1) White/Black (7) Blue/Black (11) Blue/White (15) Blue/Red (19) White/Black/Red (23) 1 Blue (6) Orange/Black (10) Green/White (14) Orange/Red (18) 2 4 6 3 5 White (2) Green (4) Red/Black (8) Black/White (12) Black/Red (16) Red/Green (20) Red/Black/White (24) Black/Red/Green (28) Orange/Black/Green (32) Orange/White/Blue (36) Black/White/Red (22) Blue/Black/White (27) Orange/Black/White (26) Green/Black/Orange (31) Red/Black/Green (30) White/Red/Orange (35) Black/White/Orange (34) Black/White/Green (38) Red/White/Green (40) 7 8 9 10 11 12 13 14 15 16 17 18 1 Blue/Black (11) Red/White (13) Green (4) Orange (5) NC NC NC Blue/White (15) White/Red (17) Blue/Red (19) Red/Green (20) 2 4 6 8 10 12 14 16 18 3 5 7 9 11 13 15 17 Black (1) White (2) Black/White (12) Green/White (14) NC NC NC Red/Black (8) Green/Black (9) Black/Red (16) Orange/Red (18) 1492-CAB➊K69 ➋ 1 Red (3) Orange (5) White/Black (7) Green/Black (9) Blue/Red (19) Red/Green (20) Blue/Black (11) Red/White (13) Blue/White (15) White/Red (17) 2 4 6 8 10 12 14 16 18 3 5 7 9 11 13 15 17 Black (1) White (2) Green (4) Blue (6) Red/Black (8) Orange/Black (10) Black/White (12) Green/White (14) Black/Red (16) Orange/Red (18) 1492-CAB➊L69 Red (3) Orange (5) NA White/Black (7) Green/Black (9) NA Blue/Black (11) Red/White (13) NA Blue/White (15) White/Red (17) NA NA NA NA NA Red/Green (20) NA Black (1) 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 4 22 3 21 2 20 1 Green (4) Blue (6) NA Red/Black (8) Orange/Black (10) NA Black/White (12) Green/White (14) NA Black/Red (16) Orange/Red (18) NA NA NA NA NA Blue/Red (19) White (2) 1492-CAB➊M69 Flex D-shell End 1492-CAB➊A94 ➊ Refer to footnote on page 149.Digital/Analog Programmable Controller Wiring Systems 147 Digital Cable Specifications. Continued L 1 Pinouts. Publication 1492-TD008D-EN-P -January 2009 . End 1 39 28 40 29 41 45 42 46 59 47 60 48 61 49 62 50 57 1 58 2 Conductor Color Code Connectors 40-Pin Reference.148 Digital/Analog Programmable Controller Wiring Systems Digital Cable Specifications. End 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Connector 62 Pin D–Shell Reference. End 1 15 23 16 24 17 4 18 5 19 Conductor Color Code Connectors 40Pin Reference. Continued Cable Wiring Table Conductor for 1492-CAB➊B94 2 Connector 62 Pin D–Shell Reference. End 2 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Orange/Green Black/White/Red White/Black/Red Red/Black/White Green/Black/White Orange/Black/White Blue/Black/White Black/Red/Green White/Red/Green Red/Black/Green Green/Black/Orange Orange/Black/Green Blue/White/Orange Black/White/Orange White/Red/Orange Orange/White/Blue White/Red/Blue Black/White/Green White/Black/Green Red/White/Green 1 43 22 39 40 6 20 7 21 8 36 25 37 26 38 27 End 2 End 1 1492-CAB➊B94 11 12 13 14 15 16 17 18 19 20 21 22 23 White (2) Red (3) Green (4) Orange (5) Blue (6) White/Black (7) Red/Black (8) Green/Black (9) White (2) Red (3) Green (4) Orange (5) Green/White (14) Black/White (12) Red/White (13) Blue/White (15) Green/White (14) Black/White (12) Red/White (13) Blue/White (15) 24 25 26 White/Red (17) Blue/Red (19) Red/Green (20) Orange/Red (18) Black (1) Orange/Black (10) 21 22 23 11 12 13 14 15 16 17 18 1492-CAB A7H Orange/Black (10) Black (1) Green/White (14) Black/White (12) Red/White (13) Blue/White (15) White/Red (17) Blue/Red (19) Red/Green (20) Orange/Red (18) White/Red (17) Blue (6) White/Black (7) Red/Black (8) Green/Black (9) Blue/Red (19) Red/Green (20) Orange/Red (18) 1 2 3 4 5 6 7 8 Red/Black (8) White (2) Red (3) Green (4) Green/Black (9) Orange (5) Blue (6) White/Black (7) 9 10 11 12 13 14 15 16 24 25 26 1492-CAB B7H ➊ Refer to footnote on page 149. 1492-CAB A7S Publication 1492-TD008D-EN-P -January 2009 . Continued 21 42 62 1 Pinouts. 0 m). Also refer to Build-to-Order Length Cables on page 65. Continued I/O Module-Ready Cables WD3 Writer Designed tag 3Digital/Analog Programmable Controller Wiring Systems The I/O module-ready cables have a pre-wired wiring arm or removable terminal block on one end to connect the programmable controller I/O module and 12…40 individually colored #18 or #22 AWG conductors on the other.Digital/Analog Programmable Controller Wiring Systems 149 Digital Cable Specifications. Example: Catalog Number 1492-CABLE025WH is for a 2. and 050 = 5. and Orange (Catalog Number CABLE➊RTBR. while still allowing the flexibility to wire to standard terminal blocks. and 5.0 m.5 m cable with a pre-wired 1771-WH Wiring Arm on one end. 025 = 2. Publication 1492-TD008D-EN-P -January 2009 .0 m. Pre-wired I/O module connectors include: • Catalog Number 1746-N3 40-point plug-in connector (Catalog Number CABLE➊N3) • Bulletin 1746 16-point removable terminal blocks in Red. insert the code for the desired cable length into the catalog number (010 = 1. 2. ➊RTBB. These cables provide the convenience of a pre-wired I/O module connector.5 m.5 m. Blue.0 m. To order. ➊RTBO) • Catalog Number 1756-TBCH 36-point removable terminal block (Catalog Number CABLE➊TBCH) • Catalog Number 1756-TBNH 20-point removable terminal block (Catalog Number CABLE➊TBNH) • Catalog Number 1769-RTBN10 8-point removable terminal block (Catalog Number CABLE➊RTN10) • Catalog Number 1769-RTBN18 20-point removable terminal block (Catalog Number CABLE➊RTN18) • Catalog Number 1769-RTBN32I and 1769-RTBN320 for 32-point 1769 I/O modules • Catalog Number 1771-WH 16-point wiring arm (Catalog Number CABLE➊WH) • Catalog Number 1771-WN 32-point wiring arm (Catalog Number CABLE➊WN) • Catalog Number 1771-WHF 16-point fused wiring arm (with fuses) (Catalog Number CABLE➊WHF) • Catalog Number 1771-WD 6-point wiring arm (Catalog Number CABLE➊WD) • Catalog Number 1771-WA 8-point wiring arm (Catalog Number CABLE➊WA) ➊ Cables are available in lengths of 1. 4 mm (0.7 mm (0.0.) 62-pin male D-shell➌ 9.0 m 1. 5.55 in. No.) 14.0 m 1. 2.0 m 1.0 m 1. Publication 1492-TD008D-EN-P -January 2009 .0.5. 2.36 in.) 11.36 in. 5.4 mm (0. 5. 2.0 m 1. 1794-TB62DS.4 mm (0.5.46 in.5.45 in.0. 2.0.4 mm (0.0. 5.0 m 1.0. 2.0. 5.36 in. and 050 = 5. 2.45 in.0. 2. 2.36 in. 2.0.0.5. Continued Insulation Rating 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C Number of Conductors 40 20 20 20 40 20 Conductor Size #22 AWG #18 AWG #18 AWG #18 AWG #18 AWG #18 AWG #18 AWG #22 AWG #18 AWG #18 AWG #22 AWG #22 AWG #18 AWG #18 AWG #22 AWG #22 AWG #22 AWG #22 AWG #18 AWG #18 AWG #18 AWG #18 AWG #18 AWG Nominal Outer Diameter 11. 5.5 m.5.45 in. 2.5.) 37-pin male D-shell➋ 11.5.46 in. 2.0 m 1. Example: Catalog Number 1492-CABLE025WH is for a 2. 5.0.) 11. 5. 5. ➋ Mates with Bul.0. 2.5.45 in. 2.0 m 1.0 mm (0.5.5. 5.5 m.5.44 in.0 mm (0. 2. Continued I/O Module-Ready Cable Specifications Catalog Number 1492-CABLE➊N3 1492-CABLE➊RTBB 1492-CABLE➊RTBO 1492-CABLE➊RTBR 1492-CABLE➊TBCH 1492-CABLE➊TBNH 1492-CAB➊T62 1492-CAB➊X62 1492-CAB➊T64 1492-CAB➊U64 1492-CAB➊W64 1492-CAB➊X64 1492-CAB➊RTN10 1492-CAB➊RTN18 1492-CAB➊RTN32I 1492-CAB➊RTN32O 1492-CAB➊G94 1492-CAB➊H94 1492-CABLE➊WA 1492-CABLE➊WD 1492-CABLE➊WH 1492-CABLE➊WHF 1492-CABLE➊WN Cable Lengths 1.0.5.0 m 1. To order.0 mm (0.5.0 m I/O Module-Ready Cables. 5.5. -24BWA Output Terminal 11. 2.) 1771-WHF (16-Point/21 Terminal) Fused Wiring Arm 14.0 m 1.) 1771-WH (16-Point/21 Terminal) Wiring Arm 11.55 in.) 1762-L40xxx Input Connector 11. and 5.) 1771-WD (6-Point/12 Terminal) Wiring Arm 11.45 in.) 9.0 m 1.52 in. 2.) 13.2 mm (0.45 in.0 m 1. 1794 Flex D-shell style base: Cat.7 mm (0. 5.0. 1794 Flex D-shell style base: Cat.2 mm (0.0 m.0 m 1.4 mm (0.) 25 40 20 20 20 20 12 20 40 40 20 40 12 12 20 20 40 I/O Module Connector 1746-N3 (40-Point) Plug-in Connector 1746-RT25B Blue Removable Terminal Block 1746-RT25C Orange Removable Terminal Block 1746-RT25R Red Removable Terminal Block 1756-TBCH (36-Point) Removable Terminal Block 1756-TBNH (20-Point) Removable Terminal Block 1762-L40xxx Output Connector 11. 5.5.5.) (2) 1769-RTBN18 (20-Point) Removable Terminal Block 11.5.0 m 1.) 1771-WA (8-Point/10 Terminal) Wiring Arm 9.5.0.0. 5.5.0.5.5.) (2) 1769-RTBN18 (20-Point) Removable Terminal Block 9.) 1769-RTBN10 Removable Terminal Block 11. 2.0 m 1.0 m 1. 1794-TB37DS.) 1764-28BXB Output Terminal 9.0.45 in.7 mm (0.46 in.) 1764-24AWA.150 Digital/Analog Programmable Controller Wiring Systems Digital Cable Specifications. 2.46 in. insert the code for the desired cable length into the catalog number (010 = 1.7 mm (0.1 mm (0. 5. 5.0 mm (0. 5. 2.0 m.0 m 1.0. 2.5 m cable with a pre-wired 1771-WH Wiring Arm on one end.5.0 m 1.0 m.5. No.4 mm (0. 5. 2.0 m 1.) 1769-RTBN18 (20-Point) Removable Terminal Block 11.1 mm (0. 5. Also refer to Build-to-Order Length Cables on page 65. 2. -BWA Input Terminal 1764-28BXBH Input Terminal 9.36 in.36 in. 5.4 mm (0. 5. 2. ➌ Mates with Bul.0 m).0 mm (0.) 1764-24AWA.0.0. 025 = 2. 5.0 m 1.0.0 m 1.45 in.0.0 mm (0.) 11.4 mm (0.45 in.) 11.0 m 1.) 1771-WN (32-Point/40 Terminal) Wiring Arm ➊ Cables are available in lengths of 1.4 mm (0. 2. 5. 0 m. Also refer to Build-to-Order Length Cables on page 65. insert the code for the desired cable length into the catalog number (010 = 1.5 m.0 m).5 m.Digital/Analog Programmable Controller Wiring Systems 151 Digital Cable Specifications. and 5. 025 = 2. Publication 1492-TD008D-EN-P -January 2009 . To order. Continued I/O Module-Ready Cables. Continued Wire Colors for I/O Module-Ready Cables and IFM Pint Reference Number for I/O Ready Pre-Wired Cables IFM Pin Reference Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Wire Color Base/Stripe/Stripe Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green IFM Pin Reference Number 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 Wire Color Base/Stripe/Stripe Orange/Green Black/White/Red White/Black/Red Red/Black/White Green/Black/White Orange/Black/White Blue/Black/White Black/Red/Green White/Red/Green Red/Black/Green Green/Black/Orange Orange/Black/Green Blue/White/Orange Black/White/Orange White/Red/Orange Orange/White/Blue White/Red/Blue Black/White/Green White/Black/Green Red/White/Green ➊ Cables are available in lengths of 1.0 m. 2. Example: Catalog Number 1492-CABLE025WH is for a 2.0 m. and 050 = 5.5 m cable with a pre-wired 1771-WH Wiring Arm on one end. Example: Catalog Number 1492-CABLE025WH is for a 2. The reference number is used in the illustrations that follow to indicate the corresponding screw terminal.5 m.0 m. Each conductor is given a reference number in the table on page 151. insert the code for the desired cable length into the catalog number (010 = 1. 1492-CABLE➊TBNH 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 2 4 6 8 10 12 14 16 18 20 1 3 5 7 9 11 13 15 17 19 1492-CABLE➊N3 1 2 1492-CABLE➊TBCH 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 1492-CABLE➊WN 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 1492-CABLE➊WH 1492-CABLE➊WF 39 40 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 A B C D 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 CAUTION A DISCONNECT POWER B BEFORE SERVICING FUSES C ALL FUSES 30-250V D 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 E E 1492-CABLE➊WD 1 2 3 4 5 6 7 8 9 10 11 12 1492-CABLE➊WA 1 2 3 4 5 6 7 8 9 10 1492-CABLE➊RTBR 1492-CABLE➊RTBB 1492-CABLE➊RTBO 1 3 5 7 9 11 13 15 17 1492-CAB➊T62 Red/Black/White Green/Black/White Black/White/Red White/Black/Red White/Red/Green 1492-CAB➊X62 Blue/Black/White Orange/Black/White Green/Black/While Black/Red/Green Orange/Green Red/Black/White White/Black/Red Black/White/Red Orange/Red Blue/Red Orange/Green White Blue/White Red/Green Black/Red White/Red Red/Green White/Red White Black 6 8 10 12 14 16 18 (Low Row) (High Row) Row B 1 2 1 2 3 3 4 4 5 5 6 6 7 7 8 8 9 10 11 1213 9 10 11 12 (High Row) Row B Row A 1 1 (Low Row) 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 1 0 1 1 1 2 1 3 1 41 5 9 10 11 1213 14 Row A Red Blue/White Green/White Blue/Black Orange/Black Green/Black Red/White Black/White White/Black Orange Blue White/Black Red/Black Orange/Black Red/White 1492-CAB➊T64 Orange/Green Green/White Blue/White Black/Red White/Red Orange/Red Red/Green Green//White Green/Black Blue/Black Black/White 1492-CAB➊U64 Orange/Red Blue/Red Red/Black Green Orange Green Red Red/White Black (High Row) Row B Row A (High Row) Row B Row A 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 10 9 10 11 1 (Low Row) Black 1 2 2 3 3 4 4 5 5 6 6 7 7 8 (Low Row) Red Orange Green/Black White/Black Red Orange White/Black Green Orange/Black Blue/Red Red/Green 8 9 9 10 10 11 Black/White ➊ Cables are available in lengths of 1. Continued I/O Module-Ready Cables. Publication 1492-TD008D-EN-P -January 2009 Orange/Black Green/Black Blue/Black Black/White Blue Red/Black Blue/Black Red/Black Green White White Blue Orange/Green Red/White Green/White Blue/White Black/Red White/Red Blue Black 4 Black/Red Blue/Red 2 Ornage/Red . R=Right) connected to a single cable assembly. Continued Below is the wire color table for I/O module-ready cables. and 5. To order.5 m.0 m.0 m). 2.152 Digital/Analog Programmable Controller Wiring Systems Digital Cable Specifications. and 050 = 5. ➋ The 1492-CABRTN32F and -RTN320 are made up of two (2) individual 18-pin terminal blocks (L = Left.5 m cable with a pre-wired 1771-WH Wiring Arm on one end. Also refer to Build-to-Order Length Cables on page 65.0 m. 025 = 2. 0 m. ➋ The 1492-CAB➊RTN32I and -RTN320 are made up of two (2) individual 18-pin terminal blocks (L = Left. and 050 = 5.22 1.2 3 5 7 8 9 11 12 13 15 17 18 19. Continued 1492-CAB➊W64 White/Yellow White/Orange White/Red White/Brown White/Black Black White/Green White/Blue 1492-CAB➊X64 White/Yellow White/Orange White/Red White/Brown White/Black Black White/Green White/Blue 1492-CAB➊RTN10 (High Row) Row B Row A (High Row) Row B Row A 1 1 2 (Low Row) 2 3 3 4 4 5 5 6 6 7 7 8 8 9 1 1 2 (Low Row) 2 3 3 4 4 5 5 6 6 7 7 8 8 9 3 4 6 8 10 12 6 8 10 12 14 5 7 9 11 13 1 2 5 7 9 11 White Yellow Orange Brown Violet Blue Red White Yellow Orange Green Brown Violet Blue Gray Gray Red 1492-CAB➊RTN18 Green 1492-CAB➊RTN32I 1492-CAB➊RTN320➋ R L 1 2 4 6 8 10 12 14 16 18 R 21. 025 = 2. ➌ Cable 1492-CAB➊G94 and -CAB➊H94 do not follow the cable wire color code chart on page151. Publication 1492-TD008D-EN-P -January 2009 .0 m. insert the code for the desired cable length into the catalog number (010 = 1.0 m. and 5.5 m cable with a pre-wired 1771-WH Wiring Arm on one end.5 m.40 34 36 28 30 24 26 21 22 24 26 28 30 32 34 36 38 Cable Wiring Table Conductor for 1492-CAB➊H94 62-Pin D-shell End Conductor Color Code Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green 62-Pin D-Shell End 39 28 40 29 41 45 42 46 59 47 60 48 61 49 62 50 57 1 58 2 Conductor Color Code Orange/Green Black/White/Red White/Black/Red Red/Black/White Green/Black/White Orange/Black/White Blue/Black/White Black/Red/Green White/Red/Green Red/Black/Green Green/Black/Orange Orange/Black/Green Blue/White/Orange Black/White/Orange White/Red/Orange Orange/White/Blue White/Red/Blue Black/White/Green White/Black/Green Red/White/Green 21 Red Orange NA White/Black Green/Black NA Blue/Black Red/White NA Blue/White White/Red NA NA NA NA NA Red/Green NA Black 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 37 36 35 34 33 32 31 30 29 28 27 26 25 24 42 62 15 23 16 24 17 4 18 5 19 6 20 7 21 8 36 25 23 4 22 3 21 2 20 1 Green Blue NA Red/Black Orange/Black NA Black/White Green/White NA Black/Red Orange/Red NA NA NA NA NA Blue/Red White 1 1492-CAB➊G94 ➌ 43 22 37 26 38 27 End 1492-CAB➊H94 ➌ ➊ Cables are available in lengths of 1.20 14 16 10 4 6 3 4 6 8 10 12 14 16 18 20 2 4 6 8 10 12 14 16 18 1 3 5 7 9 11 13 15 17 1 2 5 7 9 11 13 15 17 19 L 2 4 6 8 10 12 14 16 18 2 4 6 7 8 10 11 12 14 16 17 18 13 15 9 1 3 5 1 3 5 7 9 11 13 15 17 22 24 26 28 30 32 34 36 38 1 3 5 7 9 10 11 12 13 15 17 18 14 16 2 4 6 8 21 23 25 27 29 31 33 35 37 3 5 7 9 11 13 15 17 19 20 23 25 27 29 31 33 35 37 39 40 23 25 27 29 31 32 33 35 37 38 39.5 m. To order. 2.Digital/Analog Programmable Controller Wiring Systems 153 Digital Cable Specifications. Also refer to Build-to-Order Length Cables on page 65.0 m). Example: Catalog Number 1492-CABLE025WH is for a 2. R=Right) connected to a single cable assembly. ) 2A 1492-IFM20_ _ _ 1492-XIM20_ _ _ 11.0 m.0 m Each colored conductor is connected to one pin of the molded cable connector as listed in the tables below.5. 2. 2.5 m.5. Continued IFM-Ready Cable Specifications IFM-ready cables have a cable connector on one end to attach to the IFM and either 20 or 40 individually colored conductors on the other end (Catalog Numbers CABLE➊P and CABLE➊Q. 5.7 mm (0.0 m. Publication 1492-TD008D-EN-P -January 2009 .5 m. IFM-Ready Cable Specifications Catalog Number 1492-CABLE➊P 1492-CABLE➊Q Cable Lengths Insulation Rating 300V 80°C 300V 80°C Number of Conductors 20 40 Conductor Size #22 AWG #22 AWG Nominal Outer Diameter Current/ Compatible Conductor IFM Catalog Numbers 9. and 5. Also refer to Build-to-Order Length Cables on page 65.0 m). respectively).154 Digital/Analog Programmable Controller Wiring Systems Digital Cable Specifications. 2. These cables allow the IFM to be used in specialty applications that require a custom connection.0.) 2A 1492-IFM40_ _ _ 1492-XIM40_ _ _ 1. 20 conductor IFM-ready cable.46 in.0. insert the desired cable length into the catalog number (010 = 1.0 mm (0. 1492-CABLE➊P Connector Pin Number 1 2 3 4 5 6 7 8 9 10 Wire Color Base/Stripe/Stripe Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Connector Pin Number 11 12 13 14 15 16 17 18 19 20 Wire Color Base/Stripe/Stripe Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green ➊ Cables are available in lengths of 1.0 m 1. 025 = 2. Example: Catalog Number 1492-CABLE025P is for a 2. and 050 = 5.5 m.0 m. To order. 5.36 in. Example: Catalog Number 1492-CABLE025P is for a 2. 025 = 2. To order.5 m. 2.5 m. 20 conductor IFM-ready cable.0 m.0 m. Also refer to Build-to-Order Length Cables on page 65.5 m.0 m. Publication 1492-TD008D-EN-P -January 2009 .Digital/Analog Programmable Controller Wiring Systems 155 Digital Cable Specifications. insert the desired cable length into the catalog number (010 = 1. Continued 1492-CABLE➊Q Connector Pin Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Wire Color Base/Stripe/Stripe Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Connector Pin Number 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 Wire Color Base/Stripe/Stripe Orange/Green Black/White/Red White/Black/Red Red/Black/White Green/Black/White Orange/Black/White Blue/Black/White Black/Red/Green White/Red/Green Red/Black/Green Green/Black/Orange Orange/Black/Green Blue/White/Orange Black/White/Orange White/Red/Orange Orange/White/Blue White/Red/Blue Black/White/Green White/Black/Green Red/White/Green ➊ Cables are available in lengths of 1. and 5. Continued IFM-Ready Cable Specifications.0 m). and 050 = 5. com/raise.156 Digital/Analog Programmable Controller Wiring Systems Analog IFM Specifications (1492-AIFM-xx and 1492-RAIFM-xx)) AIFM Catalog Number 1492-AIFM8-3. refer to page 187. . for Page No. A1 A2 A3 A4 A5 . . B1 B2 B3 B4 B5 . -RAIFM4-3 1492-AIFM6S-3. For Field-Side Wiring Diagrams. . -RAIFM8-3 1492-AIFM4-3. for Page No. refer to page 181. Refer to page 186 for specific platform web site information. Publication 1492-TD008D-EN-P -January 2009 . . . .ab. . for Application Specifications Notes. . B1 B2 B3 B4 B5 . and Pinout 158 157 158 159 Page No. . Symbols and Terminal Identification Conventions Used Throughout the Pinout Section 1492-AIFM Field-Side Terminal ➊ 1492 Pre-Wired Cable I/O Module Connection Fuse and Blown Fuse Indicator One-Pole DIP Switch Two-Pole DIP Switch 1492-AIFM and Cable Connection (D-Shell Pin) Test Point ➊ Field-Side Terminal Identification Convention: C1 C2 C3 C4 C5 . . Refer to the online documentation for new product information. and Pinout 160 161 162 163 188 188 188 188 AIFM Catalog Number 1492-AIFM16-F-5 1492-AIFMPI 1492-AIFMQS — Page No. for Application Specifications Notes. A1 A2 A3 A4 A5 . for Application Notes. for Specifications 188 188 188 188 AIFM Catalog Number 1492-AIFM4C-F-5 1492-AIFM4I-F-5 1492-AIFM8-F-5 1492-AIFM16-F-3 Page No. -RAIFM6S-3 1492-AIFM6TC-3 Page No. For general Adhesive Label Card information. refer to the Wiring System web page at http://www. and Pinout 164 166 165 — 188 188 188 — For all AIFM dimensions. 2. Dimensions — Refer to page 188. 6. refer to the Wiring System web site information on page 186. 450 Ω for -OFE3). Test Points — With optional 250 Ω series impedance in output circuit (refer to DIP Switches).Digital/Analog Programmable Controller Wiring Systems 157 1492-AIFM4-3 1492-RAIFM4-3 Feed-Through 4-channel Input. 11 TP7 10 TP8 B2 B5 9 D-Shell Housing B6 A4 A8 B4 B8 Publication 1492-TD008D-EN-P . 250 Ω series impedance is inserted into the output circuit. 3. 4. Output or 2-in/2-out Combination with 3 Terminals/Channel Pinout 2 A3 B3 A7 B7 A1 1 TP1 8 TP2 15 TP3 14 TP4 A2 A5 13 A6 TP5 TP6 B1 Application Notes 12 1. do not exceed the voltage and current ratings of the AIFM.January 2009 . By opening the switch (off or down position). DIP Switches — Selectable resistors are available to current limit the Catalog Numbers 1771-OFE2 and -OFE3 output circuits. For Field-Side Wiring Diagrams. Wiring — Refer to the Label Section on page 181. 5. Default switch position is on/closed/no series impedance. Shield Terminals — Four field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing. Do not exceed maximum loop impedance of output module (1200 Ω for -OFE2. Compatibility — To ensure proper operation with the I/O module. test points can be used to measure loop voltage/current. Refer to the Pinout for test point circuit location. 4. 3..158 Digital/Analog Programmable Controller Wiring Systems 1492-AIFM6S-3 1492-RAIFM6S-3 Feed-Through 6-Channel Isolated with 3. the terminals are also internally connected to module common through the prewired cable. Shield Terminals — Six field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing. 4. Refer to the AIFM and ACABLE pinouts. refer to the Wiring System web site information on page 186.4 Terminals/Channel 1492-AIFM8-3 1492-RAIFM8-3 Feed-Through 8-Channel Differential 16-Channel SingleEnded with 3 Terminals/Channel Application Notes 1. Compatibility — To ensure proper operation with the I/O module. 2.. refer to the Wiring System web site information on page 186. Dimensions — Refer to page 187. For Field-Side Wiring Diagrams. Dimensions — Refer to page 187. Application Notes 1. For Field-Side Wiring Diagrams. 3. Shield Terminals — Eight field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing. 2. For some I/O modules. do not exceed the voltage and current ratings of the AIFM. Wiring — Refer to the Label Section on page 181. 5. Extra Terminals — Eight field-side terminals are jumpered together on the AIFM. Wiring — Refer to the Label Section on page 181. Compatibility — To ensure proper operation with the I/O module. do not exceed the voltage and current ratings of the AIFM.January 2009 . Pinout 13 12 25 24 11 23 22 9 21 19 6 18 17 4 16 15 2 14 D-Shell Housing A2 A4 A6 A8 A10 A12 B1 A1 B2 B3 A3 B4 B5 A5 B6 B7 A7 B8 B9 A9 B10 B11 A11 B12 Pinout 3 2 1 14 15 16 17 18 12 13 25 24 23 22 20 21 B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 B16 4 6 8 10 19 A9 A10 A11 A12 A13 A14 A15 A16 D-Shell Housing A1 A2 A3 A4 A5 A6 A7 A8 Publication 1492-TD008D-EN-P . do not exceed the voltage and current ratings of the AIFM. Do not install the cold junction sensor (provided with the Catalog Number 1756-IT6I or 1756-IT6I2 thermocouple input module) on the removable terminal block of the pre-wired cable.) that do not have external CJC capability.g. For Field-Side Wiring Diagrams. 5. Dimensions — Refer to page 187. Cold Junction Compensation — This AIFM contains on-board cold junction compensation (CTC) through a thermistor (T) and isothermal bar mounted to the field-side terminals. 4. 2. bulletin numbers 1746. Wiring — Refer to the Label Section on page 181.Digital/Analog Programmable Controller Wiring Systems 159 1492-AIFM6TC-3 Thermocouple 6-Channel with 3 Terminals/Channel Pinout 13 25 24 23 22 21 19 18 17 16 15 14 6 T B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 A7 Application Notes 1. 3. 20 12 11 9 4 2 A1 A3 A5 A9 A11 D-Shell Housing A2 A4 A6 A8 A10 A12 Publication 1492-TD008D-EN-P . refer to the Wiring System web site information on page 186. Compatibility — To ensure proper operation with the I/O module. Shield Terminals — Six field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing. This module is NOT compatible with other PLC systems (e.January 2009 . etc. 1771. A8 D-Shell Housing A9 . test points (TP1-TP2) can be used to measure input loop current. Test Points — When using a two-wire transmitter. 6. Do not exceed 2 A per input. For Field-Side Wiring Diagrams. Isolation — The fuse clips and blown fuse indicators are internally connected to one power source field-side terminal. . 8. . Fuses (5 x 20 mm) are not included.160 Digital/Analog Programmable Controller Wiring Systems 1492-AIFM4C-F-5 Fusible 2-channel Input. 3 Terminals/Output Pinout 8 B1 15 B2 14 B3 13 B4 12 B5 11 B6 2 10 9 B7 B8 B9 B10 B11 TP1 TP2 A1 TP3 TP4 A2 B12 A5 . 5 Terminals/Input. 3. 7. 2. 4. unused inputs can be jumpered to module common by closing the DIP switches (ON position) for analog modules that have this capability.January 2009 . . A12 Application Notes 1. refer to the Wiring System web site information on page 186. Dimensions — Refer to page 187. 12 A per AIFM. Fusing — Fuse holders are included with the AIFM. do not exceed the voltage and current ratings of the AIFM. . . 1 Publication 1492-TD008D-EN-P . Extra Terminals — Four field-side terminals are internally jumpered on the AIFM. Compatibility — To ensure proper operation with the I/O module. Wiring — Refer to the Label Section on page 181. DIP Switches — For ease of wiring. . 5. 2-Channel Output with 24V DC Blown Fuse Indicators. 9. Default switch position is OPEN/OFF/NOT jumpered together. They can be used for power source common connections. Test Points. Shield Terminals — Four field-side terminals are jumpered together on AIFM and internally connected to the D-shell housing. All inputs must reference the same power source. Refer to the Pinout for test point circuit location. Extra Terminals — Four field-side terminals are internally jumpered on the AIFM. All inputs must reference the same power source. . . 3. 12 A per AIFM. A4 B12 A5 . . A8 D-Shell Housing A9 . 5 Terminals/Input Pinout 8 B1 15 B2 14 B3 13 B4 12 B5 11 2 B6 B7 10 B8 Application Notes 1. 9 1 B9 B10 B11 TP1 TP2 A1 . 2. 4. . . They can be used for power source common connections. Fusing — Fuse holders are included with the AIFM. do not exceed the voltage and current ratings of the AIFM. . A12 TP7 TP8 Publication 1492-TD008D-EN-P .Digital/Analog Programmable Controller Wiring Systems 161 1492-AIFM4I-F-5 Fusible 4-Channel Input with 24V DC Blown Fuse Indicators. unused inputs can be jumpered to module common by closing the DIP switches (ON position) for analog modules that have this capability. Wiring — Refer to the Label Section on page 181. Fuses (5 x 20 mm) are not included. Isolation — The fuse clips and blown fuse indicators are internally connected to one power source field-side terminal. For Field-Side Wiring Diagrams. . 8. Shield Terminals — Four field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing. Do not exceed 2 A per input. . 6. Default switch position is OPEN/OFF/NOT jumpered together. 5. Compatibility — To ensure proper operation with the I/O module. . DIP Switches — For ease of wiring. . Dimensions — Refer to page 187. 9. Test Points. test points (TP1-TP2) can be used to measure input loop current. Test Points — When using a two-wire transmitter.January 2009 . Refer to the Pinout for test point circuit location. refer to the Wiring System web site information on page 186. 7. . . 2. Shield Terminals — Eighteen field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing. . .162 Digital/Analog Programmable Controller Wiring Systems 1492-AIFM8-F-5 Fusible 8-Channel Input with 24V DC Blown Fuse Indicators. 12 A per AIFM. Dimensions — Refer to page 187. Compatibility — To ensure proper operation with the I/O module. . Extra Terminals — Nine field-side terminals are internally jumpered on the AIFM. . refer to the Wiring System web site information on page 186. 4. 5. . For Field-Side Wiring Diagrams. Wiring — Refer to the Label Section on page 181. . . . DIP Switches — For ease of wiring. B18 D-Shell Housing A1 . Fuses (5 x 20 mm) are not included. . 7. B9 B10 . . unused inputs can be jumpered to module common by closing the DIP switches (ON position) for analog modules that have this capability. Isolation — The fuse clips and blown fuse indicators are internally connected to one power source field-side terminal. 8. A18 Publication 1492-TD008D-EN-P .January 2009 . 5 Terminals/Channel Pinout 3 C1 2 1 C2 C3 14 15 C4 C5 16 17 C6 C7 18 12 C8 C9 13 25 C10 C11 24 23 C12 C13 Application Notes 1. Do not exceed 2 A per input. 3. All inputs must reference the same power source. They can be used for power source common connections. Fusing — Fuse holders are included with the AIFM. Default switch position is OPEN/OFF/NOT jumpered together. . . do not exceed the voltage and current ratings of the AIFM. 6. 22 20 C14 C15 21 6 19 C16 B1 B2 . Wiring — Refer to the Label Section on page 181. do not exceed the voltage and current ratings of the AIFM. 3 Terminals/Channel Pinout 3 2 1 14 15 16 17 18 12 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 B16 B17 B18 B1 C1 . refer to the Wiring System web site information on page 186. 2. 7.Digital/Analog Programmable Controller Wiring Systems 163 1492-AIFM16-F-3 Fusible 16-Channel Inputs with 24V DC Blown Fuse Indicators. . 3. 13 25 24 23 22 20 21 4 6 8 10 19 Publication 1492-TD008D-EN-P . Do not exceed 2 A per input. All inputs must reference the same power source. Compatibility — To ensure proper operation with the I/O module. . 6. Isolation — The fuse clips and blown fuse indicators are internally connected to one power source field-side terminal. . Fusing — Fuse holders are included with the AIFM. A18 Application Notes 1. . DIP Switches — For ease of wiring. 5. Dimensions — Refer to page 187. . For Field-Side Wiring Diagrams. Shield Terminals — Eighteen field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing. . C16 D-Shell Housing A1 . 12 A per AIFM. . unused inputs can be jumpered to module common by closing the DIP switches (ON position) for analog modules that have this capability. . Default switch position is OPEN/OFF/NOT jumpered together.January 2009 . Fuses (5 x 20 mm) are not included. 4. . Wiring — Refer to the Label Section on page 181. . . . . . . . . Do not exceed 2 A per input. 7. For Field-Side Wiring Diagrams. DIP Switches — For ease of wiring. . Fusing — Fuse holders are included with the AIFM. All inputs within a group(TB1 or TB2) must reference the same power source. B18 A18 B1 B2 . B18 D-Shell Housing SH A1 . A8 A1 . Fuses (5 x 20 mm) are not included. . . do not exceed the voltage and current ratings of the AIFM. 5. 4. Compatibility — To ensure proper operation with the I/O module. 8. C16 B1 B2 . unused inputs can be jumpered to module common by closing the DIP switches (ON position) for analog modules that have this capability. . . Pinout Application Notes 1. 12 A per AIFM. 2. B9 B10 . . . . Shield Terminals — Sixteen field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing. . Eighteen field-side terminals (B10…B18 on TB1 and TB2) are internally jumpered on the AIFM and can be used for power source common connections.January 2009 . refer to the Wiring System web site information on page 186. . B9 B10 . A8 Publication 1492-TD008D-EN-P . 5 Terminals/Channel TB2 TB1 6. . There are two field-side terminals (A17 and A18 on TB1) that can be externally jumpered to connect the two groups of field-side terminals. 3. . Default switch position is OPEN/OFF/NOT jumpered together. . Extra Terminals — Sixteen field-side terminals (C9…C16 on TB1 and TB2) are internally jumpered on the AIFM and connected to module common. Dimensions — Refer to page 187. 3 2 1 14 15 16 17 18 TB1 C1 C2 C3 C4 C5 C6 C7 C8 C9 . C16 A17 4 6 8 10 19 12 13 25 24 23 22 20 21 TB2 C1 C2 C3 C4 C5 C6 C7 C8 C9 .164 Digital/Analog Programmable Controller Wiring Systems 1492-AIFM16-F-5 Fusible 16-Channel Input with 24V DC Blown Fuse Indicators. Isolation — The fuse clips and blown fuse indicators are internally connected to two separate power source field-side terminals. 6. Fuses (5 x 20 mm) are not included. 4. Extra Terminals — Four field-side terminals (on TB1) are internally jumpered on the AIFM and connected to module common.Interrogate 4 + Return 4 .Return 3 Drive Output 3 Drive Common + Interrogate 4 . -INT 4 +RET 4 -RET 4 +OUT 4 OUT COM COM LDT COM LDT COM GND SH SH -V -V1F -V4F +V +V1F +V4F 7 1 Blue/Red 21 13 LDT Common LDT Common Orange/Black DRAIN Publication 1492-TD008D-EN-P .Return 2 Drive Output 2 ➌ + Interrogate 3 . Compatibility — To ensure proper operation with the I/O module. 7.Return 1 Drive Output 1 Drive Common + Interrogate 2 . do not exceed the voltage and current ratings of the AIFM. 5. Shield Terminals — Eight field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing.Return 4 Drive Output 4 Application Notes 1. For Field-Side Wiring Diagrams. Four field-side terminals (on TB1) are internally jumpered on the AIFM and can be used for power source common connections. All inputs within a group must reference the same power source. 3.Interrogate 1 + Return 1 . Fusing — Fuse holders are included with the AIFM.Interrogate 2 + Return 2 .January 2009 . 12 A per AIFM.Interrogate 3 + Return 3 . Dimensions — Refer to page 187.Digital/Analog Programmable Controller Wiring Systems 165 1492-AIFMQS Fusible 4-Input/4 Output Channel with 8 Fuses & 24V DC Blown Fuse Indicators Pinout +INT 1 -INT 1 +RET 1 -RET 1 +OUT 1 OUT COM +INT 2 -INT 2 +RET 2 -RET 2 +OUT 2 OUT COM +INT 3 -INT 3 +RET 3 -RET 3 +OUT 3 OUT COM +INT 4 6 18 20 19 5 17 3 15 4 16 2 Black/Blue Blue/Black Black/Orange Red/Gray Gray/Red Red/Brown Brown/Red Red/Green Green/Red Red/Orange Orange/Red 4 5 15 6 9 8 22 14 23 24 18 12 24 13 25 11 23 9 21 10 22 8 Red/Blue White/Gray Gray/White White/Brown Brown/White White/Green Green/White White/Orange Orange/White White/Blue Blue/White 1 11 2 3 17 26 10 19 20 12 25 + Interrogate 1 . Isolation — The fuse clips and blown fuse indicators are internally connected to two separate power source field-side terminals. 2. refer to the Wiring System web site information on page 186. Wiring — Refer to the Label Section on page 181. Do not exceed 3 A per input. 25 A. 4. 6. Pinout Refer to page 167. All inputs must reference the same power source. Shield Terminals — Eight field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing. do not exceed the voltage and current ratings of the AIFM. For Field-Side Wiring Diagrams. Wiring — Refer to the Label Section on page 181. 7. Isolation — The fuse clips and blown fuse indicators are internally connected to one power source field-side terminal. 8. Eight fuses (0. Compatibility — To ensure proper operation with the I/O module. Publication 1492-TD008D-EN-P . refer to the Wiring System web site information on page 186. Fusing — Two fuse holders for the outputs are included with the AIFM. Jumpers — J0…J7 provide the option of connecting the negative inputs to the return. 3. 5. 5 x 20 mm) are included with the fused supply inputs. Dimensions — Refer to page 187. J8 commons the shield to the return. Default switch position is OPEN/OFF/NOT jumpered together. Do not exceed 2 A per output.166 Digital/Analog Programmable Controller Wiring Systems 1492-AIFMPI Fusible 8-Input/2 Output Channels Application Notes 1.January 2009 . 2. The 1492-AIFMPI is designed exclusively for the 1757-PIM module. January 2009 . Continued CN 1 2 3 TB + J0 TB B9 V0 +24 CHANNEL 0 – F0 B2 + 1 2 3 1 2 3 J7 F1 B4 CHANNEL 7 – B1 F2 B6 9 22 SHELL J8 F3 B3 B5 B7 B10 B12 B14 B16 V0 A9 RTN SHIELD IN 0.7 B8 +V FUSED 0-7 F4 B11 F5 B13 F6 B15 F7 B17 12 24 CHANNEL 0 1 2 3 4 5 6 7 4 14 3 15 2 16 1 17 8 18 7 19 6 20 5 21 A1 +0 A2 –0 A3 +1 A4 –1 A5 +2 A6 –2 A7 +3 A8 –3 A10 +4 A11 –4 IN IN B18 F8 25 B19 V1 +DC OUT 0 OUT 1 IN 13 F9 B20 IN IN A12 +5 IN A13 –5 A14 +6 IN A15 –6 A16 +7 IN A17 –7 V1 RTN A19 RTN OUT 0 A20 RTN OUT 1 A18 Publication 1492-TD008D-EN-P .. Continued Pinout.Digital/Analog Programmable Controller Wiring Systems 167 1492-AIFMPI.. or Bul. replace the pointto-point wiring between Allen-Bradley programmable controller I/O modules and individual terminal blocks. The broad offering of analog pre-wired cables supports over 40 different Bulletin 1746. Bulletin 1756 Removable Terminal Block. Analog pre-wired cables. 1794-TB37DS) on one end and a D-shell on the other to connect to the AIFM. Publication 1492-TD008D-EN-P -January 2009 . 1769. Digital/Analog Programmable Controller Wiring Systems Pre-Wired Cables Specifications The pre-wired cables have a Bulletin 1746 Removable Terminal Block. most analog cables have prepared ring lugs on the drain wire for convenient grounding of the cable shield to the programmable controller chassis. 1771. RTD. Bulletin 1771 Wiring Arm. and 1794 analog.168 Digital/Analog Programmable Controller Wiring Systems Analog Cable Specifications Bulletin 1492 pre-wired cables are designed to minimize control wiring in a panel. In addition. 700S. 700H. when used with an AIFM. All analog cables have an overall shield and most have #22 AWG twisted pairs for additional noise immunity. 1756. No. Bulletin 1769 Removable Terminal Block. The analog ready-to-wire cables provide one end of the cable pre-terminated for an AIFM (AIFM-ready cable). and thermocouple (1756 only) I/O modules. 1794 (Flex) 37-pin D-Shell (mates with Cat. 5.0.0.43 mm (0.5.44 mm (0.0.0 m 0.5. Continued Analog Pre-Wired Cable Specifications Catalog Number and Length ➊ 1492-ACABLE➊A 1492-ACABLE➊B 1492-ACABLE➊C 1492-ACABLE➊D 1492-ACABLE➊E 1492-ACABLE➊F 1492-ACABLE➊G 1492-ACABLE➊H 1492-ACABLE➊J 1492-ACABLE➊K 1492-ACABLE➊L 1492-ACABLE➊M 1492-ACABLE➊P 1492-ACABLE➊Q 1492-ACABLE➊R 1492-ACABLE➊X 1492-ACABLE➊Y 1492-ACABLE➊YT 1492-ACABLE➊Z 1492-ACABLE➊A46 1492-ACABLE➊TA 1492-ACABLE➊TB 1492-ACABLE➊TC 1492-ACABLE➊TD 1492-ACABLE➊UA 1492-ACABLE➊UB 1492-ACABLE➊UC 1492-ACABLE➊UD 1492-ACABLE➊VA 1492-ACABLE➊VB 1492-ACABLE➊WA 1492-ACABLE➊WB 1492-ACABLE➊XA 1492-ACABLE➊XB 1492-ACABLE➊ZA 1492-ACABLE➊ZB 1492-ACABLE➊ZC 1492-ACAB➊AA69 1492-ACAB➊AB69 1492-ACAB➊BA69 1492-ACAB➊BB69 1492-ACAB➊BC69 1492-ACAB➊BD69 1492-ACAB➊C69 1492-ACAB➊CA69 1492-ACAB➊CB69 1492-ACAB➊CC69 1492-ACAB➊D69 1492-ACAB➊EA69 1492-ACAB➊EB69 1492-ACAB➊ED69 1492-ACAB➊HA69 Standard Cable Lengths 0.5. 2.0 m 0.5.267") 8.Digital/Analog Programmable Controller Wiring Systems 169 Analog Cable Specifications. 5. 2.5 mm (0. 2.5.0.0 m 0.0 m 0.0 m 0. 2.332") 7.293") 11.5.78 mm (0.5.332") 8. 5. 5.0 m 0. 1.45") 1746-RT28 12-Position Removable Terminal Block 1746-RT26 2-Position and 1746-RT27 8-Position Removable Terminal Block 1746-RT25G Green Removable Terminal Block 1746-RT25G Green Removable Terminal Block 1771-WG (21 terminal) 1771-WG (21 terminal) Wiring Arm 1771-WC (10 terminal) Wiring Arm 1771-WF (18 terminal) Wiring Arm 1771-WF (18 terminal) Wiring Arm 1746-RT25G Green Removable Terminal Block 1746-RT28 12-Position Removable Terminal Block 1756-TBCH 36-Position Removable Terminal Block 1746-RT25G Green Removable Terminal Block 1746-QS (26 terminal D-shell) 1746-RT25G Green Removable Terminal Block 1756-TBNH 20-Position Removable Terminal Block 1756-TBNH 20-Position Removable Terminal Block 1756-TBNH 20-Position Removable Terminal Block 1756-TBNH 20-Position Removable Terminal Block 1746-RT25G Green Removable Terminal Block 1756-TBCH 36-Position Removable Terminal Block 1756-TBCH 36-Position Removable Terminal Block 1756-TBCH 36-Position Removable Terminal Block 1756-TBCH 36-Position Removable Terminal Block 1756-TBCH 36-Position Removable Terminal Block 1756-TBCH 36-Position Removable Terminal Block 1756-TBCH 36-Position Removable Terminal Block 1756-TBCH 36-Position Removable Terminal Block 1756-TBNH 20-Position Removable Terminal Block 1756-TBNH 20-Position Removable Terminal Block 1756-TBNH 20-Position Removable Terminal Block 1756-TBNH 20-Position Removable Terminal Block 1756-TBCH 36-Position Removable Terminal Block 1756-TBCH 36-Position Removable Terminal Block 1756-TBCH 36-Position Removable Terminal Block 1756-TBCH 36-Position Removable Terminal Block 1756-TBCH 36-Position Removable Terminal Block 1769-RTBN10 12-Position Removable Terminal Block 1769-RTBN10 12-Position Removable Terminal Block 1769-RTBN18 20-Position Removable Terminal Block 1769-RTBN18 20-Position Removable Terminal Block 1769-RTBN18 20-Position Removable Terminal Block 1769-RTBN18 20-Position Removable Terminal Block 1769-RTBN18 20-Position Removable Terminal Block 1769-RTBN18 20-Position Removable Terminal Block 1769-RTBN18 20-Position Removable Terminal Block 1769-RTBN18 20-Position Removable Terminal Block 1769-RTBN18 20-Position Removable Terminal Block 1769-RTBN18 20-Position Removable Terminal Block 1769-RTBN18 20-Position Removable Terminal Block 1769-RTBN18 20-Position Removable Terminal Block 1769-RTBN18 20-Position Removable Terminal Block Publication 1492-TD008D-EN-P -January 2009 . 1. 1. 5. 5.332") 8. 1.5.2 mm (0.5.5. 5.5 mm (0. 2.5.0 m 0. 2.293") 6.332") 8. 2.78 mm (0. 1.0.5. 5. 2.5.0 m 0.5. 2.5.0.5.0 m 0.5.43 mm (0.0 m 0.293") 7. 1. 1.332") 8.44 mm (0.5.45") 11.332") 8. 2.0 m 0. 5. 1.5.5. 5. 2.43 mm (0.5. 1.0.5.5.5. 2.332") 8.5. 5.5 mm (0. 1. 2. 5.0.0. 5.5. 2.5.0 m 0. 1.0 m 0. 5.0.43 mm (0. 2.0 m 0. 1.5. 5. 1.0. 2.0. 1.0.5.0.5.5.5. 1.0. 1.293") 7.0 m 0.5. 2.332") 8.78 mm (0.332") 6.44 mm (0. Continued AIFM Connector 15-pin D-shell 15-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 15-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 15-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 15-pin D-shell 15-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 15-pin D-shell 15-pin D-shell 15-pin D-shell 15-pin D-shell 15-pin D-shell 15-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell No.5.43 mm (0.267") 11.0. 1.5.43 mm (0.0 m 0.5.0 m 0. 5.44 mm (0.44 mm (0.5. 2.5. 5.0.5.43 mm (0. 5.43 mm (0.0. 2. 2. 2.332") 8.0 m 0.44 mm (0.2 mm (0.43 mm (0.0 m 0.267") 6. 2. 2.0. 1. 5.43 mm (0.5. 5.5.5 mm (0.5.0 m 0.78 mm (0.44 mm (0. 1.332") 11.5.5.5. 2.0 m 0.0 m 0.0 m I/O Module Connector Pre-Wired Cables. 1.0 m 0.0. 1.0.332") 8.0. 5.0 m 0. 1.0. 5.267") 6. 2.0 m 0. 5.293") 7.0.43 mm (0.0 m 0.78 mm (0.267") 8.0 m 0. 2.267") 6. 2.43 mm (0.5. 2.5.5. 1. 5.5.0 m 0.293") 7.5. 1.0 m 0. 1.43 mm (0.43 mm (0.0 m 0. 5.0 m 0. 5.5.5. 2. 2. 5. 5.293") 8. 5.5.5.78 mm (0.5. 2. 2.5.0.267") 6.332") 11. 5.332") 8.44 mm (0.0.5. 1. 2. 1.0.5. 2.0.0.293") 7.5. 2.5. 5.0.5.0 m 0.0 m 0.5. 2. 2. 5.0.5.0.0 m 0. 1.332") 10.5.43 mm (0.0 m 0. 5. 5. 5. 2.0.78 mm (0. 2.43 mm (0.0 m 0.0. 2.0.5.78 mm (0.78 mm (0. 2.43 mm (0. 2. of Conductors ➋➌ 5 Twisted Pairs 5 Twisted Pairs 9 Twisted Pairs 20 Conductors 9 Twisted Pairs 20 Conductors 5 Twisted Pairs 9 Twisted Pairs 20 Conductors 11 Twisted Pairs 5 Twisted Pairs 11 Twisted Pairs 11 Twisted Pairs 12 Twisted Pairs 20 Conductors 9 Twisted Pairs 9 Twisted Pairs 9 Twisted Pairs 20 Conductors 20 Conductors 20 Conductors 20 Conductors 5 Twisted Pairs 5 Twisted Pairs 20 Conductors 20 Conductors 9 Twisted Pairs 9 Twisted Pairs 20 Conductors 20 Conductors 9 Twisted Pairs 9 Twisted Pairs 11 Twisted Pairs 11 Twisted Pairs 20 Conductors 20 Conductors 20 Conductors 5 Twisted Pairs 5 Twisted Pairs 5 Twisted Pairs 5 Twisted Pairs 5 Twisted Pairs 5 Twisted Pairs 20 Conductors 20 Conductors 20 Conductors 20 Conductors 20 Conductors 20 Conductors 20 Conductors 20 Conductors 11 Twisted Pairs Insulation Rating 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C 300V 80°C Conductor Size 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG Nominal Outer Diameter 7. 1.0 m 0. 2.43 mm (0.0.332") 8.0 m 0.5. 2.5.332") 8.0.0.5.332") 8.0 m 0.0 m 0. 1. 1.5.78 mm (0.0 m 0.0.5.5. 5. 1. 5.5. 1.0 m 0. 2. 5.5.0.5.293") 7. 5.5.5. 5. 1.0 m 0.332") 8.43 mm (0. 2.5. 1. 1.0. 1.0. 2.0.43 mm (0. 1.0. 1. 2. 1. 1.0 m 0. 5.332") 8. 1. 5.267") 8.5.0 m 0.293") 6.5. 1. 1. 2.5. 1.332") 7.5.40") 8.5.332") 6.0.0 m 0.5.5. 5.5.5.0 m 0. 2. 5.267") 8.45") 11.45") 10.44 mm (0. 5.5 mm (0. 5.5.5.0 m 0. 1.5.0 m 0. 1.43 mm (0.0.5.5.5.0. 1.45") 8.5.0.0.5. 5. 1.0.267") 8. 2.5.5. 1.5. 2. 1. 5.45") 7. 5.44 mm (0.43 mm (0.43 mm (0.0.5.40") 8.5.5.43 mm (0. 5. 1. 5.5.332") 6. 5.5 mm (0.0 m 0. 5.0 m 0.332") 6.0.5.5. 5. 010 = 1.0. and 050 = 5. 2. No.78 mm (0.0 m 0.5.5. the drain wire is connected to the shield terminal on the I/O module connector. 2. 5.5.0.170 Digital/Analog Programmable Controller Wiring Systems Analog Pre-Wired Cable Specifications Catalog Number and Length ➊ 1492-ACAB➊Z7H 1492-ACAB➊Z7S 1492-ACAB➊X7S 1492-ACAB➊Z94 Standard Cable Lengths 0. of Conductors ➋➌ 9 Twisted Pairs 9 Twisted Pairs 9 Twisted Pairs 20 Conductors Insulation Rating 300V 80°C 300V 80°C 300V 80°C 300V 80°C Conductor Size 22 AWG 22 AWG 22 AWG 22 AWG Nominal Outer Diameter 6.5.267") 6. ➌ Not every connection is always used. 5. On 1492-ACABLE➊C and 1492-ACABLE➊D.87" (200 mm) exposed drain wire at the I/O module end of the cable.5. 2.5 m. Also refer to Build-to-Order Length Cables on page 65.43 mm (0.332") ➊ Cables are available in standard lengths of 0. 025 = 2. 1.0 m 0.0 m. ➋ All pre-wired analog cables have an overall shield. All other 1492-ACABLEs have a ring lug on the 7. To order.5. 1.0 m I/O Module Connector 20C-DA1-A or 20C-DA1-B I/O Board Terminal TB1 (Pins 1…12) Terminal TB1 (Pins 13…25) 37-Pin D-Shell Connector to Mate with Cat. 2.267") 8.5.5 m. Publication 1492-TD008D-EN-P -January 2009 . Example: Catalog Number 1492-ACABLE005A is for a 0.5 m. 2.78 mm (0.0 m.267") 6. 1794-TB37DS Base AIFM Connector 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell No.5 m and 5. 5.0.5.0 m). insert the desired cable length code into the catalog number (005 = 0.0. 1.78 mm (0. 1.0 m.0 m 0. 1.5 m cable for the 1746-NI4 I/O Module. The description listed first is the wire color of the conductor connected to the screw terminal on the respective Wiring Arm or Removable Terminal Block. Continued Pinouts Analog Pre-Wired Cables The following diagrams indicate how the analog pre-wired cables are connected on both ends. The number that follows in parentheses is the corresponding pin number in the D-shell connector on the other end.Digital/Analog Programmable Controller Wiring Systems 171 Analog Cable Specifications. Shield Base Color Stripe Color Blue (24) NC Black (23) White/Green (22) 20 or 40 Connector Pin Number White/Red (19) No Connection Twisted Pair Individual Conductor Jumper Wire Output Pin Connector Definition 15 1 25 1 1 1 9 8 14 13 15-Pin D-Shell Connector 25-Pin D-Shell Connector AIFM Mating Connector Definition Publication 1492-TD008D-EN-P -January 2009 . 172 Digital/Analog Programmable Controller Wiring Systems Analog Cable Specifications. Continued NC Red (3) Black (2) White (1) Black (14) 0 1 2 3 4 5 6 7 8 9 10 11 Black (1) NC Blue (10) Black (9) Yellow (2) Green (12) Black (11) 4 5 6 7 Green (12) Black (11) Blue (10) Black (9) Drain NC White (14) Black (13) 0 1 2 3 Red (8) Black (15) White (14) Black (13) Red (8) Black (15) 0 1 Green (15) Black (16) Blue (17) Black (18) Yellow (12) Black (13) Brown (25) Black (24) Orange (23) Black (22) Red (20) White (21) Yellow (2) Black (1) 1492-ACABLE___A 1492-ACABLE___B 1492-ACABLE___C 1 2 3 4 5 NC Red (3) Black (2) White (1) Black (14) 1 2 3 4 5 Red (3) Brown (2) Black (1) White (14) Orange (4) White/Black (15) White/Brown (16) White/Red (17) White/Orange (18) Blue (10) Violet (12) Gray (13) White/Black/Brown (25) White/Gray (24) Green (8) White/Violet (23) White/Blue (22) White/Yellow (20) White/Green (21) Yellow (6) NC NC NC Blue (13) White/Blue (24) White/Violet (25) White/Green (23) Green (12) Yellow (11) NC NC White/Yellow (22) White/Red (19) White/Orange (21) White/Brown (18) Orange (9) Red (6) NC Drain 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 NC NC Green (15) Black (16) Blue (17) Black (18) 6 7 8 9 10 Yellow (12) Black (13) Brown (25) Black (24) 11 12 13 14 15 Orange (23) Black (22) Red (20) White (21) Red (6) Green (19) 16 17 18 19 20 21 1492-ACABLE___D 1492-ACABLE___E 1492-ACABLE___F Publication 1492-TD008D-EN-P -January 2009 . Continued Pinouts. Continued Red (8) Black (15) White (14) Black (13) Green (12) Black (11) Blue (10) Black (9) NC NC A 0 12 10 NC NC Red (3) Black (2) White (1) Black (14) Green (15) Black (16) Blue (17) Black (18) 18 16 14 12 10 1 2 3 4 5 2 8 6 4 6 7 B Yellow (12) Black (13) Brown (25) Black (24) Orange (23) Black (22) Red (20) White (21) 8 6 4 2 White/Violet (25) Green (12) Blue (13) White/Green (23) Yellow (11) White/Blue (24) White/Orange (21) Orange (9) White/Yellow (22) White/Brown (18) Red (6) White/Red (19) White (16) Brown (4) White/Black (17) Violet (14) Black (2) Gray (15) Red (25) Red (13) White (15) Green (3) Blue (4) Yellow (5) Brown (1) Red (9) Black (10) Black (24) NC NC Green (23) Blue (21) Black (22) Black (18)* Black (20) Orange (17) Yellow (19) Black (14) White (11) 1492-ACABLE___K* 1492-ACABLE___G 1492-ACABLE___H (3) White (15) Black NC NC 2 1492-ACABLE___J Red (9) 1 0 1 2 3 4 5 6 7 8 9 10 11 NC NC NC NC Red (8) Black (15) Red (4) Black (14) NC NC Black (10) White (11) Black (24) Green (23) Black (22) Blue (21) Black (20) Yellow (19) Black (18) Orange (17) Black (16) White (15) Green (3) Blue (4) Red (13) Red (25) White (14) Black (13) (1) Blue (17) Black (7) Brown (19) Black NC NC NC NC Green (2) Black (16) Yellow (8) Black (18) NC NC NC NC NC NC Green (11) Black (2) (5) Red (21) White (24) Red (13) Blue Orange (6) Black (20) Red (12) Green (25) Brown (1) Black (14) NC NC Blue (9) Black (1) Yellow (5) 36 35 1492-ACABLE___L 1492-ACABLE___M White/Black (15) 1492-ACABLE___P* NC 9 Red/Brown (5) Brown/Red (17) Red/Green (20) Green/Red (19) Orange/Red (18) Red/Orange (6) Orange/White (25) White/Orange (13) Blue/White (24) White/Blue (12) 1 18 26 Black/Orange (2) Orange/Black (1) Green/White (23) White/Green (11) Blue/Black (16) Black/Blue (4) Gray/Red (15) Red/Gray (15) Gray/White (22) White/Gray (22) White/Brown (16) NC White/Red (17) NC White/Orange (18) NC Violet (12) NC Gray (13) Green (8) Red/Blue (8) Blue/Red (7) Brown/White (22) White/Brown (9) 10 White-Black/Brown (25) Orange (4) White/Gray (24) Red (3) Brown (2) NC White/Yellow (20) White/Green (21) 19 1492-ACABLE___Q * Cable uses twisted pair conductors. 1492-ACABLE___R Publication 1492-TD008D-EN-P -January 2009 . Continued 18 16 14 Pinouts.Digital/Analog Programmable Controller Wiring Systems 173 Analog Cable Specifications. Continued Red (3) Black (1) White/Black (15) White/Red (17) Orange (4) Yellow (6) Violet (12) White/Black/Brown (25) White/Violet (23) White/Yellow (20) 2 4 6 8 1 3 5 7 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 20 29 32 31 34 33 36 35 White/Brown (16) Brown (2) Gray (13) Brown (2) White (14) White/Brown (16) White/Orange (18) Gray (13) White/Gray (24) White/Blue (22) White/Green (21) 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 30 29 32 31 34 33 36 35 1492-ACABLE___TA Red (3) Black (2) White (1) Black(14) Green (15) Black (16) Blue (17) Black (18) 1492-ACABLE___TB 2 4 6 8 1 3 5 7 Yellow (6) Black (21) 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 30 29 32 31 34 33 36 35 Yellow (6) Black (21) Red (3) Black (2) White (1) Black(14) Green (15) Black (16) Blue (17) Black (18) 2 4 6 8 1 3 5 7 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 30 29 32 31 34 33 36 35 Red (3) Brown (2) Black (1) White (14) Orange (4) White/Black (15) White/Brown (16) White/Red (17) White/Orange (18) Violet (12) Gray (13) White/Black/Brown (25) White/Gray (24) Blue (10) White/Violet (23) White/Blue (22) White/Yellow (20) White/Green (21) 2 4 6 8 1 3 5 7 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 30 29 32 31 34 33 36 35 Yellow (6) Green (8) 1492-ACABLE___TC Red (3) Brown (2) Black (1) White(14) 1492-ACABLE___TD Red (3) Black (2) White (1) Black(14) Green (15) Black (16) Blue (17) Black (18) Yellow (12) Black (13) Brown(25) Black (24) Orange (23) Black (22) Red (20) White (21) 1492-ACABLE___UA 2 4 6 8 1 3 5 7 2 4 6 8 1 3 5 7 Orange (4) Yellow (6) White/Black (15) White/Brown (16) White/Red (17) White/Orange (18) Violet (12) Gray (13) White/Black/Brown (25) White/Gray (24) Green (8) Blue (10) White/Violet (23) White/Blue (22) White/Yellow (20) White/Green (21) 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 30 29 32 31 34 33 36 35 Red (6) Green (19) Red (3) Black (2) White (1) Black(14) Green (15) Black (16) Blue (17) Black (18) Yellow (12) Black (13) Brown(25) Black (24) Orange (23) Black (22) Red (20) White (21) 2 4 6 8 1 3 5 7 J1 J2 J3 J4 J5 J6 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 30 29 32 31 34 33 36 35 Red (6) Green (19) 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 30 29 32 31 34 33 36 35 J7 J8 1492-ACABLE___UB 1492-ACABLE___UC 1492-ACABLE___UD Publication 1492-TD008D-EN-P -January 2009 . Continued Red (3) Black (1) White/Black (15) White/Red (17) Orange (4) White/Blue (22) Yellow (6) Violet (12) White/Black/Brown (25) White/Violet (23) White/Yellow (20) 2 4 6 8 1 3 5 7 Pinouts.174 Digital/Analog Programmable Controller Wiring Systems Analog Cable Specifications. Continued Pinouts. Continued 2 4 6 8 1 3 5 7 2 1 3 5 7 Red (8) Black (15) Black (13) White (14) 4 6 8 Red (8) Black (15) Black (13) White (14) 10 9 12 11 14 13 16 15 18 17 20 19 10 9 12 11 Green (12) Black (11) Black (9) Blue (10) 14 13 16 15 18 17 20 19 Green (12) Black (11) Black (9) Blue (10) 1492-ACABLE___VA 1492-ACABLE___VB 2 1 3 5 7 2 1 3 5 7 NC Red (3) Black (2) Black (14) White (1) Yellow (12) Black (13) Black (24) Brown (25) 4 6 8 Red (3) Black (2) Black (14) White (1) Yellow (12) Black (13) Black (24) Brown (25) 4 6 NC 8 10 9 12 11 10 9 12 11 14 13 16 15 Orange (23) Black (22) White (21) Red (20) Green (15) Black (16) Black (18) Blue (17) Black (22) Orange (23) White (21) Red (20) 14 13 16 15 18 17 20 19 NC 18 17 20 19 Green (15) Black (16) Black (18) Blue (17) Red (6) Green (19) 1492-ACABLE___WA 1492-ACABLE___WB Blue (24) 2 4 1 3 5 7 Red (13) Blue (24) NC 2 4 6 8 1 3 5 7 Red (13) NC Black (25) White (22) NC Black (21) NC Green (17) NC Black (16) Black (23) Yellow (19) 6 8 Black (25) White (22) Black (23) Yellow (19) 10 9 10 9 Black (18) NC Orange (15) 12 11 14 13 16 15 18 17 Black (21) NC Green (17) Black (18) Brown (6) Black (20) Orange (15) NC 12 11 14 13 16 15 18 17 20 19 Black (14) 20 19 Black (16) Black (14) 1492-ACABLE___X 1492-ACABLE___Y Publication 1492-TD008D-EN-P -January 2009 .Digital/Analog Programmable Controller Wiring Systems 175 Analog Cable Specifications. Continued 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 30 29 32 31 34 33 36 35 Orange (17) NC Black (16) Yellow (19) NC Black (18) Blue (21) NC Black (20) NC NC NC Blue (4) Yellow (5) Black (14) Red (2) NC Red (25) NC Green (23) Black (22) NC White (11) Black (24) NC Red (9) Black (10) NC NC NC White (15) Green (3) Brown (1) Red (12) NC Red (13) 2 4 6 8 1 3 5 7 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 30 29 32 31 34 33 36 35 NC Orange (17) Black (16) NC Yellow (19) Black (18) NC Blue (21) Black (20) NC NC NC Blue (4) Yellow (5) Black (14) Red (2) NC Red (25) White/Blue (24) Yellow (11) White/Green (23) White/Red (19) Red (6) White/Brown (18) NC Gray (15) Black (2) Violet (14) 2 4 6 8 1 3 5 7 Blue (13) Green (12) White/Violet (25) White/Yellow (22) Orange (9) White/Orange (21) NC White/Black (17) Brown (4) White (16) 10 9 12 11 14 13 16 15 18 17 20 19 1492-ACABLE___XA* 1492-ACABLE___XB* 1492-ACABLE___Z White/Green (23) White/Yellow (22) White (16) Gray (15) NC NC NC Violet (14) Black (2) NC NC NC NC NC NC NC 2 4 6 8 1 3 5 7 White/Violet (25) White/Blue (24) White/Brown (18) White/Black (17) NC NC NC Blue (13) White/Orange (21) NC NC NC NC NC NC NC 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 30 29 32 31 34 33 36 35 White/Green (23) NC White/Yellow (22) White (16) NC Gray (15) NC NC Violet (14) NC Black (2) NC NC NC NC NC NC NC 2 4 6 8 1 3 5 7 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 30 29 32 31 34 33 36 35 White/Violet (25) NC White/Blue (24) White/Brown (18) NC White/Black (17) NC NC Blue (13) NC White/Orange (21) NC NC NC NC NC NC NC Black (23) Blue (24) Black (25) Red (13) Black (20) Brown (6) 2 4 6 8 1 3 5 7 1492-ACABLE___ZA 10 9 1492-ACABLE___ZB 12 11 14 13 16 15 White/Green (23) White/Yellow (22) White (16) Gray (15) NC NC Violet (14) NC Black (2) NC NC NC NC NC NC NC 2 4 6 8 1 3 5 7 18 17 White/Violet (25) White/Blue (24) White/Brown (18) White/Black (17) NC NC Blue (13) NC White/Orange (21) NC NC NC NC NC NC NC 20 19 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 30 29 32 31 34 33 36 35 Red(3) Black (1) Violet (15) White (17) Orange (6) Yellow (12) White/Violet (25) White/Green (23) White/Red (20) 1 3 5 7 9 11 13 15 17 2 4 6 8 10 12 14 16 18 Brown (2) Blue (14) Gray (16) White/Black (18) White/Brown (19) Green (13) White/Blue (24) White/Yellow (22) White/Orange (21) Black (21) White (22) Black (18) Yellow (19) Black (16) Green (17) Black (14) Orange (15) 1492-ACABLE___ZC * Cable uses twisted pair conductors.176 Digital/Analog Programmable Controller Wiring Systems Analog Cable Specifications. Continued Green (23) NC Black (22) White (11) NC Black (24) Red (9) NC Black (10) NC NC NC White (15) Green (3) Brown (1) Red (12) NC Red (13) 2 4 6 8 1 3 5 7 Pinouts. 1492-ACAB___A46 (Green RTB) 1492-ACABLE___YT Publication 1492-TD008D-EN-P -January 2009 . Digital/Analog Programmable Controller Wiring Systems 177 Analog Cable Specifications. Continued 2 1 3 5 7 9 11 13 15 17 Red (8) White (14) Green (12) Blue (10) Black (9) NC NC NC NC NC 2 4 6 8 10 1 3 5 7 9 Red (8) Black (15) White (14) Black (13) NC NC NC 2 1 3 5 7 9 4 NC Red (8) Black (15) NC NC Black (13) White (14) 6 8 10 12 14 16 18 NC 4 6 8 10 1492-ACAB___AA69 1492-ACAB___AB69 1492-ACAB___BA69 2 4 6 8 10 12 14 16 18 1 3 5 7 9 11 13 15 17 2 1 3 5 7 9 11 13 15 17 Red (8) White (14) Green (12) Blue (10) Black (9) NC NC NC NC NC 4 6 8 10 12 14 16 18 NC NC NC NC NC Red (8) Black (15) White (14) Black (13) Green (12) Black (11) Blue (10) Black (9) NC NC NC NC NC 2 4 6 8 10 12 14 16 18 1 3 5 7 9 11 13 15 17 Black (15) Red (8) Black (13) White (14) Black (11) Green (12) Black (9) Blue (10) 1492-ACAB___BB69 1492-ACAB___BC69 1492-ACAB___BD69 2 1 3 5 7 9 11 13 15 17 White/Yellow (22) White/Green (23) Gray (15) White (16) Black (2) Violet (14) 4 6 8 10 12 14 16 18 White/Green (23) White/Blue (24) White/Yellow (22) White/Violet (25) White/Black (17) White/Brown (18) White/Orange (21) Blue (13) White (16) Gray (15) Black (2) Violet (14) 2 4 6 8 10 12 14 16 18 1 3 5 7 9 11 13 15 17 White/Violet (25) White/Blue (24) White/Brown (18) White/Black (17) White/Orange (21) Blue (13) White/Yellow (22) White/Green (23) Gray (15) White (16) Black (2) Violet (14) 2 4 6 8 10 12 14 16 18 1 3 5 7 9 11 13 15 17 White/Blue (24) White/Violet (25) White/Black (17) White/Brown (18) White/Orange (21) Blue (13) 1492-ACAB___CA69 1492-ACAB___CB69 L 1492-ACAB___CC69 R 1 2 4 3 5 6 7 8 9 11 12 1 3 5 L 1 R 1 2 4 6 7 8 10 11 12 14 13 15 16 17 18 9 3 5 Red (3) Black (1) White/Black (15) White/Red (17) White/Green (21) Orange (4) 2 4 6 8 10 11 12 14 16 17 18 13 15 7 9 3 5 Violet (12) White/Black/Brown (25) White/Violet (23) White/Yellow (20) Yellow (6) Red (3) Black (1) White/Black (15) White/Red (17) 2 4 6 8 10 Violet (12) White/Black/Brown (25) White/Violet (23) White/Yellow (20) 7 9 11 10 13 15 16 17 18 12 14 13 15 16 17 18 14 Yellow (6) White/Green (21) Orange (4) 1492-ACAB___EA69 ➊ 1492-ACAB___EB69 ➊ Publication 1492-TD008D-EN-P -January 2009 . Continued Pinouts. End 2 13 25 24 23 22 20 21 6 19 Case — 9 7 6 8 5 Black Brown Red Orange Yellow Green Blue Violet Grey White White/Black White/Brown White/Red White/Orange White/Yellow White/Green White/Blue White/Violet White/Grey White/Black/Brown Shield — 23 4 22 3 21 2 20 1 End 2 (AIFM) End 1 (Flex Base) 1492-ACAB___Z94 ➊ Cable is made up of two (Left & Right pair) individual terminal blocks. Continued Pinouts. End 1 31 12 30 10 28 9 27 3 21 5 — Conductor Color Code Connectors 25-Pin D-Shell. End 1 1 2 19 37 18 36 16 34 15 33 13 Conductor Color Code Connectors 25-Pin D-Shell.178 Digital/Analog Programmable Controller Wiring Systems Analog Cable Specifications. Continued White/Red (19) Red (6) White/Brown (18) White/Black (17) Brown (4) White (16) Gray (15) Black (2) Violet (14) 2 4 6 8 10 12 14 16 18 1 3 5 7 9 11 13 15 17 Blue (13) Green (12) White/Violet (25) White/Blue (24) Yellow (11) White/Green (23) White/Yellow (22) Orange (9) White/Orange (21) White/Black (15) White/Brown (16) White/Red (17) White/Orange (18) Violet (12) Gray (13) White/Blue/Brown (25) White/Grey (24) Red (3) Brown (2) 2 4 6 8 10 12 14 16 18 1 3 5 7 9 11 13 15 17 Yellow (6) Orange (4) White/Yellow (20) White/Green (21) 1492-ACAB___C69 L R 1 2 4 3 5 6 7 8 9 11 12 1492-ACAB___D69 Brown (2) White (14) White/Brown (16) White/Orange (18) Yellow (6) Red (3) Black (1) White/Black (15) Gray (13) White/Gray (24) White/Blue (22) 2 4 6 8 10 1 3 5 7 9 11 Violet (12) White/Black/Brown (25) White/Violet (23) White/Yellow (20) 10 13 15 16 17 18 White/Red (17) 12 14 White/Green (21) Orange (4) 14 16 13 15 17 18 L 1492-ACAB___EC69 ➊ Brown (2) White (14) White/Brown (16) White/Orange (18) Yellow (6) 2 4 6 R 1 3 5 7 8 10 11 12 14 16 17 18 13 15 9 1 Red (3) Gray (13) White/Gray (24) White/Blue (22) 2 4 3 5 6 8 7 9 10 11 12 14 16 17 18 13 15 Violet (12) White/Black/Brown (25) White/Violet (23) White/Yellow (20) Black (1) White/Black (15) 1492-ACAB___ED69 ➊ White/Green (21) Orange (4) White/Red (17) 1492-ACAB___ED69 ➊ 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 37 36 35 34 33 32 31 30 25 24 23 22 21 20 19 18 17 4 16 3 15 13 12 11 10 2 14 1 29 28 27 26 25 24 Cable Wiring Table Conductor for 1492-ACAB__Z94 Connector 37Pin D-Shell. Publication 1492-TD008D-EN-P -January 2009 . End 2 — — 3 2 1 14 15 16 17 18 12 Connector 37Pin D-Shell. Digital/Analog Programmable Controller Wiring Systems 179 Analog Cable Specifications. Continued Pinouts. Publication 1492-TD008D-EN-P -January 2009 . 1492-ACAB Z7S * Cable uses twisted pair conductors. Continued White (15) Brown (1) Blue (4) Black (14) Black (10) Black (24) Black (22) Black (20) Black (18) Black (16) 2 4 6 8 10 12 14 16 18 1 3 5 7 9 11 13 15 17 Red (13) Red (25) Green (3) Yellow (5) Red (9) White (11) Green (23) Blue (21) Yellow (19) Orange (17) 1492-ACAB___HA69* Yellow (19) Black (18) Black (25) Red (13) Black (23) Blue (24) Black (14) Orange (15) Black (2) Yellow (19) Black (18) Green (17) Black (16) 1 2 3 4 5 6 7 8 9 10 13 14 15 16 17 18 19 20 21 22 23 24 Black (23) Blue (24) Black (21) White (22) Bare Wire (MTG) Black (18) Yellow (19) Black (16) Green (17) Black (25) Red (13) 1 2 3 4 5 6 7 8 9 10 11 12 Black (16) Orange (17) Red (9) Black (10) White (11) Black (24) Green (23) Black (22) Blue (21) Black (20) Bare Wire (MTG) 1492-ACAB Z7H 1492-ACAB X7S ➊ Cable is made up of two (Left & Right pair) individual terminal blocks. ) 34.) 10 mm (1.7 in. 73 mm 0.9 in.78 in. Refer to the Quick Reference table on Page 187 for a complete list of module dimensions. (83 mm) Length Width Publication 1492-TD008D-EN-P -January 2009 .0 mm (0.) 11.) 35. (110 mm) 3. 2.) 10 mm (1. 44 mm 2.46 in.) 9.42 in. multiply by 0.5 mm) 1. Dimensions are not to be used for manufacturing purposes.54 in.6 in.8 in.4 mm (2.9 mm (1.4 in.) 29 mm (1. 17 mm 1.50 in.3 mm (1.180 Digital/Analog Programmable Controller Wiring Systems Dimensions Approximate dimensions are shown in millimeters unless otherwise indicated (to convert to inches. Digital IFM Mating Connector 38 mm (1.7 in. (70.67 in.5 mm) Height 4. (42. 58 mm 15-Pin D-Shell Dimensions 25-Pin D-Shell Dimensions Wiring System Module Dimensions The following is an example to show the length (L) and width (W) and Height (H) dimension layout for a Wiring System Module.33 in. 17 mm 2.15 in.15 in. 39 mm 0.27 in.0394).) 54.3 in.) 20-Point Cable Dimensions 40-Point Cable Dimensions Analog D-Shell Connector 2.7 mm (0.40 in.40 in.35 in.6 in.36 in. 60 mm 1.) 39 mm (1. 39 mm 1. L1-B. Label cards can be ordered as spare parts should a replacement be required. Labels are provided in the octal and decimal numbering systems for Bulletin 1746 I/O modules. numeric labels are provided. To see an example. For example. This information is helpful for determining field-side wiring layouts prior to installation. refer to pages 182 and 183. COM. and AIFMs come with an adhesive label card. For each I/O module. etc. COM3. The label cards list all of the compatible I/O modules and their respective wiring descriptions. LED and fuse labels are also provided in octal for use with Bulletin 1771 I/O modules. the label cards contain blank label strips (for field-side terminals) and rectangular boxes (for the large group marking area on each IFM. For extra terminal modules. or +V are provided. An example of how the labels are applied is shown below: Publication 1492-TD008D-EN-P . Refer to page 187 for a listing of label cards that apply to your IFM. The label strips basically copy the wiring descriptions from the I/O module in the chassis down to the Interface Module terminals on the DIN Rail. L2. Examples: 1…20. XIFM. like the I/O modules. The label card provides the field-side connection descriptions for the programmable controller I/O module. the label strip(s) are simply peeled from the label card and applied to the field-side terminals on the Interface Module. Labels for Bulletin 1771 I/O modules are supplied in the octal numbering system. like the I/O modules themselves. Interface Modules with LEDs or fuse clips come with the LEDs or fuse clips/blown fuse indicators numbered in decimal. The LED or fuse conversion label(s) are placed directly on the circuit board of the Interface Module. XIFMs. For writeon identification.181 Marking Systems Pre-Printed and Blank Adhesive Label Cards All Bulletin 1492 IFMs. L1-C or COM1. or AIFM). and evens and odds. L1-A. COM2. corresponding labels with L1. pre-printed labels are provided to identify the power bus(ses) or commoned terminals (middle and/or lower rows of terminals) on the Interface Module.January 2009 . if generic numbering of the field-side terminals is desired. Labels for Bulletin 1756 and 1769 I/O modules are supplied in the decimal numbering system. Depending on the I/O module that is used. In addition. 1…40. Examples of available label cards are on page 182. The labels indicate isolated power busses or grouped commons with a different letter or number. OVP16 1769-OB16. Continued (Example Label Cards) I/O CAT. ITB16 IN 0 IN 00 IN 1 IN 01 IN 2 IN 02 IN 3 IN 03 IN 4 IN 04 IN 5 IN 05 IN 6 IN 06 IN 7 IN 07 IN 8 IN 10 IN 9 IN 11 IN 10 IN 12 IN 11 IN 13 IN 12 IN 14 IN 13 IN 15 IN 14 IN 16 IN 15 IN 17 COM COM COM COM +V 1746-IG16 +V +V +V IN 0 IN 00 IN 1 IN 01 IN 2 IN 02 IN 3 IN 03 IN 4 IN 04 IN 5 IN 05 IN 6 IN 06 IN 7 IN 07 IN 8 IN 10 IN 9 IN 11 IN 10 IN 12 IN 11 IN 13 IN 12 IN 14 IN 13 IN 15 IN 14 IN 16 IN 15 IN 17 COM COM COM COM 1746-IV16. NO. TC-IDX081 L1 0 IN 0 IN 1 IN 2 IN 3 L2 0 L2 0 L2 0 L2 0 L2 1 L2 1 L2 1 L2 1 IN 4 IN 5 IN 6 IN 7 L1 1 L2 1 1756-IA16. IC16. TC-IDA161 L2 0 L2 0 IN 0 IN 1 IN 2 IN 3 IN 4 IN 5 IN 6 IN 7 IN 8 IN 9 IN 10 IN 11 IN 12 IN 13 IN 14 IN 15 L2 1 L2 1 1756-IB16. OW16 (AC) L1 1 L1 1 L1 1 L1 1 OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 L1 2 L1 2 L1 2 L1 2 1746-OB16. OBP16. OG16. 0V16 +V +V +V +V OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT COM COM 15 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT COM COM 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 1746-OW16 (DC) 1769-OW16 (DC) +V1 +V1 OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT +V2 +V2 13 14 15 0 1 2 3 4 5 6 7 8 9 10 11 12 +V1 +V1 OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT +V2 +V2 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 1746-OX8 (AC) 1769-OW8I (AC) L1 0 OUT 0 L1 1 OUT 1 L1 2 OUT 2 L1 3 OUT 3 OUT 4 L1 4 OUT 5 L1 5 OUT 6 L1 6 OUT 7 L1 7 1746-OX8 (DC) 1769-OW8I (DC) +V0 OUT +V1 OUT +V2 OUT +V3 OUT 3 2 1 0 OUT +V4 OUT +V5 OUT +V6 OUT +V7 7 6 5 4 1756-IA8D. OB16E. IN16 (DC). TC-ODC081 L1 0 OUT OUT OUT OUT 1 2 3 0 L1 0 L1 0 L1 0 L1 0 L1 1 L1 1 L1 1 L1 1 OUT OUT OUT OUT 4 5 6 7 L1 1 Publication 1492-TD008D-EN-P . IN16. Part 1 of Adhesive Label Card for Catalog Numbers 1492-IFM20F. TC-IDD161.January 2009 . OV16. IN16 (AC) IN 0 IN 00 IN 1 IN 01 IN 2 IN 02 IN 3 IN 03 IN 4 IN 04 IN 5 IN 05 IN 6 IN 06 IN 7 IN 07 IN 8 IN 10 IN 9 IN 11 IN 10 IN 12 IN 11 IN 13 IN 12 IN 14 IN 13 IN 15 IN 14 IN 16 IN 15 IN 17 L2 L2 L2 L2 1746-IB16. ITV16 IN 0 IN 00 IN 1 IN 01 IN 2 IN 02 IN 3 IN 03 IN 4 IN 04 IN 5 IN 05 IN 6 IN 06 IN 7 IN 07 IN 8 IN 10 IN 9 IN 11 IN 10 IN 12 IN 11 IN 13 IN 12 IN 14 IN 13 IN 15 IN 14 IN 16 IN 15 IN 17 +V +V +V +V 1746-OA16.182 Marking Systems. -IFM20D24. OW16 (AC) 1769-OA16. IDE161 GND GND 0 0 IN 0 IN 1 IN 2 IN 3 IN 4 IN 5 IN 6 IN 7 IN 8 IN 9 IN 10 IN 11 IN 12 IN 13 IN 14 IN 15 GND GND 1 1 1756-OA8. IM16. ON8. IH16. and -IFM20D120 MODULE LABEL 1746-IA16. IC16. ICD L1 +V IN 00 IN 00 IN 00 IN 00 IN 00 IN 01 IN 01 IN 01 IN 01 IN 01 IN 02 IN 02 IN 02 IN 02 IN 02 IN 03 IN 03 IN 03 IN 03 IN 03 IN 04 IN 04 IN 04 IN 04 IN 04 IN 05 IN 05 IN 05 IN 05 IN 05 IN 06 IN 06 IN 06 IN 06 IN 06 IN 07 IN 07 IN 07 IN 07 IN 07 IN 10 IN 10 IN 10 IN 10 IN 10 IN 11 IN 11 IN 11 IN 11 IN 11 IN 12 IN 12 IN 12 IN 12 IN 12 IN 13 IN 13 IN 13 IN 13 IN 13 IN 14 IN 14 IN 14 IN 14 IN 14 IN 15 IN 15 IN 15 IN 15 IN 15 IN 16 IN 16 IN 16 IN 16 IN 16 IN 17 IN 17 IN 17 IN 17 IN 17 L2 L2 COM COM COM 1771-IGD +V +V IN 00 IN 01 IN 02 IN 03 IN 04 IN 05 IN 06 IN 07 IN 10 IN 11 IN 12 IN 13 IN 14 IN 15 IN 16 IN 17 +V COM 1771-OAD.183 Marking Systems. TC-ODA161 L1 0 L2 0 OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 L1 1 L2 1 1756-OB8. IND (DC) 1771-IMD (DC) 1771-IBD. OGD +V +V OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 +V COM NUMERIC LED LABEL 1 2 3 00 1 4 01 2 5 02 3 6 03 4 7 04 5 8 05 6 9 06 7 10 07 8 11 10 9 12 11 10 13 12 11 14 13 12 15 14 13 16 15 14 17 16 15 18 17 16 19 20 Publication 1492-TD008D-EN-P . OND. OW8 1769-OW8 (DC) L1 1 +VDC 1 OUT 0 OUT 0 OUT 1 OUT 1 OUT 2 OUT 2 OUT L1 OUT 3 4 1 OUT +VDC OUT 3 4 1 OUT 5 OUT 5 OUT 6 OUT 6 OUT 7 OUT 7 L1 L1 2 2 +VDC +VDC 2 2 1771-IAD (AC). Continued (Example Label Cards) Part 2 of Adhesive Label Card for Catalog Numbers 1492-IFM20F.January 2009 . OC8. OMD L1 L1 OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 L1 L2 1771-OBD. IND (AC) 1771-IMD (AC) 1771-IAD (DC). TC-ODX081 L2 0 OUT OUT OUT OUT 0 1 2 3 L1 0 L1 0 L1 0 L1 0 L1 1 L1 1 L1 1 L1 1 OUT OUT OUT OUT 4 5 6 7 L2 1 L1 1 1756-OA16. TC-ODE081 +DC OUT OUT OUT OUT RTN +DC +DC +DC RTN +DC +DC +DC +DC OUT OUT OUT OUT RTN RTN 0 0 1 2 3 0 0 0 0 0 1 1 1 1 4 5 6 7 1 1 1756-OB16E. and -IFM20D120 1756-OA8D. -IFM20D24. TC-ODD081. OA8E. TC-ODD161 1769-IA8I +DC RTN OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT +DC RTN 0 1 2 3 4 5 6 7 8 9 0 0 10 11 12 13 14 15 1 1 IN L2 IN L2 IN L2 IN L2 IN L2 IN L2 IN L2 IN L2 0 0 1 1 2 2 3 3 4 4 5 5 6 6 7 7 1769-IA16 IN IN IN IN IN IN IN IN IN IN IN IN IN IN IN IN L2 L2 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 L2 L2 1769-IM12 IN IN IN IN IN IN IN IN IN IN IN IN L2 L2 0 1 2 3 4 5 6 7 8 9 10 11 1769-IQ16 SINK IN IN IN IN IN IN IN IN IN IN IN IN IN IN IN COM COM COM COM IN 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 1 2 2 1769-IQ16 SOURCE +VDC +VDC IN IN IN IN IN IN IN IN IN IN IN IN IN IN IN IN +VDC +VDC 1 1 2 2 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1769-OA8 (AC). Replacement fuse holders (Catalog Number 1492-IFMFHI) are available in packages of 20. All of the fusible Bulletin 1492 IFMs and AIFMs come standard with fuse holders (for the number of fuse holders included.January 2009 . refer to the specifications for each IFM or AIFM).184 Digital/Analog Programmable Controller Wiring Systems Accessories Digital/Analog Programmable Controller Wiring Systems Catalog Number 1492-IFMFH1 Fuse Holder Catalog Number 1492-ISOSW-1 Isolation Switch Fuse Plug Catalog Number 1492-SJM5-10 Insulated Side Jumper Replacement Fuse Holders IFM The 1492-IFMFH1 fuse holders accommodate either a 5 x 20 mm fuse or the Catalog Number 1492-ISOSW-1 isolation switch plug and reside in the IFM or AIFM under normal operation. Publication 1492-TD008D-EN-P . Catalog Number 1492-IFMFHI fuse holders are not compatible with fusible expandable XIMs. Replacement Relays The relays in the Relay Master and Relay Expander modules are replaceable.January 2009 . -16R 1492-XIM20120-8R. The Catalog Number 1492-ISOSW-1 isolation switch plugs are available in packages of four. and -AIFM8-F-5 modules. If fusing is not desired on a fusible IFM or AIFM. -AIFM4I-F-5. -16RF 1492-XIM120-8R Flexible Relay Module Expansion Cable Replacement Part Catalog Number 700-HK36Z24 700-HK36Z24 700-HK36Z24 700-HK36A1 700-HK36Z24 700-HK36A1 W22101-061-01 Isolation Switch Plugs The Catalog Number 1492-ISOSW-1 is an isolation switch or “dummy fuse” in a 5 x 20 mm fuse form factor. Metering equipment can also be inserted into a two-wire transmitter circuit to measure input loop current. Replacement fuse holders are available in packages of 20. Continued Replacement Fuse Holders. -16RF 1492-XIM24-8R. Continued AIFM The Catalog Number 1492-IFMFH1 fuse holders accommodate a 5 x 20 mm fuse or the Catalog Number 1492-ISOSW-1 isolation switch fuse plug and reside in the AIFM under normal operation.Digital/Analog Programmable Controller Wiring Systems 185 Accessories. The isolation switch can then be opened for maintenance and troubleshooting. and -AIFM16-F-5 modules. -16RF 1492-XIM4024-8R 1492-XIM2024-8R. the Catalog Number 1492-ISOSW-1 isolating switch can be used to provide feed-through functionality under normal operation and isolation switch functionality once power has been removed from the circuit. All of the fusible Catalog Number 1492 AIFMs come standard with the fuse holders — 10 fuse holders with the Catalog Number 1492-AIFM4C-F-5. The isolation switch plugs will fit into the Catalog Number 1492-IFMFH1 fuse holders. Publication 1492-TD008D-EN-P . The following replacement relays must be used: Replacement Relays XIM Catalog Number 1492-XIM4024-16R. -16R. 20 fuse holders with the Catalog Number 1492-AIFM16-F-3. ” 3. XIM or AIFM wiring system modules. Click on the Accept key for the 1492 wiring system module (E.” Publication 1492-TD008D-EN-P . 7. I/O Module. Click on the Accept key for the 1492 cable. The configuration results page is displayed. Use of this jumper is a convenient means of connecting unused inputs together on the feed-through.g.g. 4. Configure the 1492 cable for your application by filling in the NO SELECTION areas. 8.” click on the “Wiring Diagram for the I/O Module to IFM. Click on the Modify key (lower left).186 Digital/Analog Programmable Controller Wiring Systems Accessories. I/O Platform. etc.January 2009 . Visit the following web site for I/O wiring diagrams of the Interface Modules and cables: 1. 1492IFM20F). Web Site Information Wiring diagrams are provided on-line if you require additional information to wire your field device to the terminals of the IFM. be sure to select the Pre-Wired Cable Connector selection. Continued Insulated Side Jumpers The Catalog Number 1492-SJM5-10 is a 10-pole “comb-style” insulated side jumper.). The jumper fits the field-side terminal spacings on all of the Bulletin 1492 IFMs and AIFMs. In the selected components table column “Supplementary Documents. The Catalog Number 1492-SJM5-10 insulated side jumpers are available in packages of 10.com/raise 2. Click on the areas that indicate NO SELECTION and enter your information (e.ab. 6. 5. To obtain the wiring diagram. A side cutter can be used to cut the 10-pole jumper into smaller pole assemblies. 9. Type in the catalog number of the IFM/XIM or AIFM you are interested in. Click on “Submit. http://www.. 33 x 3. Current Dimensions (Per Module) (W x H x D) (in.33 x 3.27 x 2. 46006-236-01 46006-190-01.27 x 2. -240-01.27 x 2. -194-01.27 x 2. -235-01 46006-211-01 46006-209-01 46006-192-01. -253-01 46006-224-01. -22101 46006-210-01 46006-190-01.33 x 3.78➌ 4.33 x 3.2 mA 1.27 x 2.6 mA 2 mA 2. -225-01. -RIFM20F 1492-IFM20FN.78 8.69 x 3.78 4.27 x 3.27 x 2. -237-01. -225-01. -195-01.27 x 2.27 x 2.36 x 3. -235-01 46006-204-01 46006-204-01 46006-215-01 46006-204-01 46006-214-01 46006-215-01 46006-214-01 46006-191-01. -RIFM40F 1492-IFM40F-2 1492-RIFM40F-2 1492-IFM40F-3 1492-IFM40D24.27 x 2. -189-01 46006-192-01.78➌ 4.33 x 3.33 x 3.33 x 3. -225-01. -195-01. -235-01. -240-01.78 4.27 x 2.4 mA 2.27 x 2.78 8.27 x 2.78➌ 4. -22001 46006-192-01.78 4.78 Indicator Circuit Current (Nominal) — — — — 2 mA 2 mA 2 mA 2 mA 1.33 x 3.Digital/Analog Programmable Controller Wiring Systems 187 Quick Reference Digital IFM Specifications Digital IFM Catalog Number 1492-IFM20F.27 x 2. 46006-233-01 46006-197-01. -237-01. -22101 46006-212-01.27 x 2.27 x 2.72 x 3.2 mA 2.33 x 3.27 x 2.78 2.33 x 3. -194-01.27 x 2. Current (Per Circuit) 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A Max.33 x 3.27 x 2.27 x 2.27 x 2. -253-01 46006-193-01. -235-01. -23901.27 x 3.27 x 3. -22101 46006-212-01.1 mA 4.27 x 3. -RIFM20F-F24A-2 1492-IFM20F-F120-2. -194-01.78 2. -23901.78 3.27 x 2.78➌ 8. -235-01.27 x 2.27 x 2. -22001 46006-192-01.1 mA 2 mA Label Card Replacement Part Catalog Number ➋ 46006-190-01.27 x 2. -253-01 46006-224-01. -189-01 46006-192-01. -RIFM20F-F-2 1492-IFM20F-F24-2.5 mA — 2 mA 2.78 4.78 6.27 x 2.33 x 3.78 4. -235-01 46006-211-01 46006-192-01.36 x 3.78 4. -22101 46006-211-01 46006-209-01 46006-193-01. 46006-233-01 46006-197-01. -RIFM20F-F120A-2 1492-IFM20F-F240-2 1492-IFM20F-FS-2 1492-IFM20F-FS24-2 1492-IFM20F-FS24A-4 1492-IFM20F-FS120-2 1492-IFM20F-FS120-4 1492-IFM20F-FS120A-4 1492-IFM20F-FS240-4 1492-IFM40F.78 4.27 x 2.5 mA 2. -195-01.5 mA 2. -240-01. -195-01.78 4. -195-01.2 mA — — — — 2 mA 2 mA 2 mA 2 mA 4.27 x 2.78 4.36 x 3.78 4.33 x 3. -RIFM20FN 1492-IFM20F-2.5 mA 2.27 x 3. -253-01 46006-208-01 46006-208-01 46006-193-01.27 x 2. -23901.27 x 2.27 x 2.27 x 2. -RIFM20F-F120-2 1492-IFM20F-F120A-2.5 mA 1.36 x 3.33 x 3.33 x 3. 46006-236-01 46006-191-01. -RIFM40D24 1492-IFM40D24-2 1492-IFM40D24A-2 1492-RIFM40D24A-2 1492-IFM40DS24-4 1492-IFM40DS24A-4 1492-IFM40D24-3 Voltage Range 0…264V AC/DC 0…132V AC/DC 0…264V AC/DC 0…132V AC/DC 10…30V AC/DC 10…30V AC/DC 10…30V AC/DC 10…30V AC/DC 10…60V AC/DC 10…30V AC/DC 85…132V AC/DC 85…132V AC 85…132V AC 85…132V AC 85…132V AC 204…264V AC 204…264V AC 0…132V AC/DC 10…30V AC/DC 10…30V AC/DC 85…132V AC/DC 85…132V AC/DC 204…264V AC/DC 0…132V AC/DC 10…30V AC/DC 10…30V AC/DC 85…132V AC/DC 85…132V AC/DC 85…132V AC/DC 204…264V AC/DC 0…132V AC/DC 0…132V AC/DC 0…132V AC/DC 0…60V AC/DC 10…30V AC/DC 10…30V AC/DC 10…30V AC/DC 10…30V AC/DC 10…60V AC/DC 10…30V AC/DC 10…30V AC/DC Max.78 3.15 x 3.15 x 3. -237-01.27 x 2. -23901.78➌ 4.78 4.27 x 2.27 x 2.78➌ 4. -22101 46006-192-01.27 x 2.27 x 2. -225-01.78➌ 2.33 x 3. -235-01. -25301 46006-224-01.)➊ 12 A 12 A 12 A 12 A 12 A 12 A 12 A 12 A 12 A 12 A 12 A 12 A 12 A 12 A 12 A 12 A 12 A 12 A 12 A 12 A 12 A 12 A 12 A 12 A 12 A 12 A 12 A 12 A 12 A 12 A 12 A 12 A 12A 12 A 12 A 12 A 12 A 12A 12 A 12 A 12 A 4.33 x 3.January 2009 .36 x 3. -234-01.33 x 3. 46006-233-01 46006-197-01.78 6.27 x 2.2 mA 1.78 2.27 x 2.27 x 2.78 4.27 x 3. -22001 46006-192-01.33 x 3.5 mA 1. -RIFM20F-2 1492-IFM20F-3 1492-IFM20D24 1492-IFM20D24N 1492-IFM20D24-2 1492-IFM20D24A-2 1492-IFM20DS24-4 1492-IFM20D24-3 1492-IFM20D120 1492-IFM20D120N 1492-IFM20D120-2 1492-IFM20D120A-2 1492-IFM20DS120-4 1492-IFM20D240-2 1492-IFM20D240A-2 1492-IFM20F-F-2.78 2.5 mA 2. -235-01. -194-01. -234-01.78 8.78 4.78 2.78➌ 8.4 mA 2.27 x 2.33 x 3.78 4.5 mA 2. 46006-236-01 Publication 1492-TD008D-EN-P . -240-01.78 4.33 x 3.33 x 3. -25201 46006-194-01.36 x 3.33 x 3. 252-01 46006-224-01.69 x 3.27 x 3. -RIFM20F-F24-2 1492-IFM20F-F24A-2.78➌ 4.6 mA 2.27 x 2.2 mA — 2 mA 2.78➌ 4.78 8.78 8.78 4. 4 mA 1. -23901. -195-01.78 7.27 x 2. -195-01 46006-201-01 46006-206-01 46006-194-01.78 8.15 x 3.78 8. -195-01.27 x 2. -240-01.74 3.27 x 2.05 mA 2.27 x 2.09 x 3.4 mA 2.5 mA — 2 mA 2. precede part number with the letter “W.188 Digital/Analog Programmable Controller Wiring Systems Digital IFM Specifications (Continued) Digital IFM Catalog Number 1492-IFM40D120-2 1492-IFM40D120A-2 1492-IFM40DS120-4 1492-IFM40DS120A-4 1492-IFM40DS240A-4 1492-IFM40F-F-2 1492-IFM40F-F24-2 1492-RIFM40F-F24-2 1492-IFM40F-F24D-2 1492-IFM40F-F24AD-4 1492-IFM40F-F120-2 1492-IFM40F-FS-2 1492-IFM40F-FS24-2 1492-IFM40F-FS24-4 1492-IFM40F-FS120-2..27 x 3.27 x 3.January 2009 .72 x 3.27 x 3. -23901.09 x 3.4 mA — — 1. 1492Rxxx module.5 mA 2.27 x 2. -RAIFM8-3 1492-AIFM8-F-5 1492-AIFM16-F-3 1492-AIFM16-F-5 1492-AIFMQS 1492-AIFMPI Voltage Range 0…10V DC 10…30V DC 10…30V DC 0…132V AC/DC 0…132V AC/DC 5…30V DC 5…30V DC 0…132V AC/DC 10…30V DC 10…30V DC 10…30V DC 10…30V DC 0…30V DC Max.74 3.5 mA➌ 1. -195-01.78 6.. -RAIFM6S-3 1492-AIFM6TC-3 1492-AIFMCE4 1492-AIFMCE4-F 1492-AIFM8-3.74 4.265V AC/DC Max. Current (Per Circuit) 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 3A 2A Max.27 x 2.09 x 3.09 x 3..72 x 3.1 mA 1.69 x 3. -RAIFM4-3 1492-AIFM4C-F-5 1492-AIFM4I-F-5 1492-AIFM6S-3. -25301 46006-208-01 46006-208-01 46006-208-01 46006-194-01.78 7. For spare part.27 x 2.09 x 3.15 x 3.27 x 2.09 x 3.27 x 2.27 x 2.27 x 2.27 x 2. -240-01.74 3.27 x 2.27 x 3.27 x 2.27 x 2.27 x 2. Max.27 x 2.27 x 3.78 7. -225-01.27 x 2.78 4.74 4.78 Indicator Circuit Current (Nominal) 2.5 mA 2.78 7.27 x 2.78 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 12 A 12 A 12 A 12 A 12 A 12 A 12A 8A 8A 12 A 12 A 12 A 12 A 12 A 12 A 12A 12 A 12 A 12 A 12A 12 A 12 A 12 A 8.4.74 3.27 x 3. -195-01.72 x 3.27 x 2. -194-01.27 x 2.74 5. -25301 46006-201-01 46006-201-01 46006-207-01 46006-201-01 46006-206-01 46006-226-01 46006-207-01 46006-226-01 46006-226-01 46006-226-01 46006-207-01 46006-226-01 46006-226-01 ➊ Dimensions are in inches.27 x 2.27 x 2.74 8.74 5.27 x 2.78 7.27 x 2.6 mA 2. To convert to millimeters..6 mA 2.72 x 3.4 mA Label Card Replacement Part Catalog Number ➋ 46006-194-01. ➋ Ships with each module.4 mA 1. -225-01.74 Indicator Circuit Label Card Current (Nominal) Replacement Part Catalog Number ➋ — 46006-205-01 2 mA 46006-203-01 2 mA 46006-203-01 — 46006-202-01 — 46006-202-01 — 46006-232-01 1 mA @ 5V DC 46006-232-01 6 mA @ 24V DC — 2 mA 2 mA 2 mA — 2 mA 46006-200-01. multiply inches by 25.74 4.09 x 3. -194-01.39 in.72 x 3.27 x 2.4 mA 2.27 x 3.27 x 2.27 x 2.78 7.6 mA — 2 mA 2 mA <0. -25301 46006-224-01.27 x 2. 46006238-01 46006-196-01.78 4.69 x 3.78 7. -25301 46006-194-01.69 x 3.15 x 3.78 7.33 x 3.264V AC/DC 0…132V AC/DC 159.72 x 3.27 x 2. -195-01 46006-224-01.09 x 3.78 7.12 x 3.78 6.27 x 2.27 x 2.78 7.78 7.78 8. Current (Per Module) 12 A 12 A 12 A 12 A 12 A 8A 8A 12 A 12 A 12 A 12 A 12 A 12 A Dimensions (W x H x D) (in.74 4.)➊ Circuit) 2A 12 A 8. Analog IFM Specifications Analog IFM Catalog Number 1492-AIFM4-3.74 4. -25401 46006-213-01 46006-198-01 46006-199-01 46006-243-01 Publication 1492-TD008D-EN-P .78 4.27 x 2. Current Dimensions Current (Per (Per Module) (W x H x D) (in.09 x 3. to the width dimension for Bul.) ➊ 2.27 x 2.78 4.4 mA 3.09 x 3.72 x 3.05 mA <0.” ➌ Add 0.36 x 3.78 8.27 x 2.78 6.09 x 3.72 x 3.27 x 2.27 x 2. -RIFM40F-FS120-2 1492-IFM40F-FS120-4 1492-RIFM40F-FS120-4 1492-IFM40F-FS240-4 1492-IFM40F-FS24A-4 1492-IFM40F-FS120A-4 1492-RIFM40F-FS120A-4 1492-IFM40F-FS-4 1492-IFM40F-FSA-4 1492-IFM40F-FS240A-4 Voltage Range 85…132V AC 85…132V AC 85…132V AC 85…132V AC 204…264V AC 0…132V AC/DC 10…30V AC/DC 10…30V AC/DC 10…30V DC 10…30V DC 85…132V AC/DC 0…132V AC/DC 10…30V AC/DC 10…30V AC/DC 85…132V AC/DC 85…132V AC/DC 85…30V AC/DC 204…264V AC/DC 10…30V AC/DC 85…132V AC/DC 85…30V AC/DC 0.12 x 3.15 x 3. Continued Relay Master/Expandable Interface Module Specifications ➊ Relay Master/Expandable XIM Catalog Number Relay Coil Voltage Range Max.26V DC 96. To convert to millimeters.15 x 3.05 x 3. For spare part.. ➋Ships with each module.27 x 2.January 2009 .05 x 3..78 10. -RXIM24-8R 1492-XIM120-8R 1492-XIM2024-16R 1492-XIM2024-16RF 1492-XIM20120-16R 1492-XIM20120-16RF 1492-XIM4024-16RF 1492-XIMF-2 1492-XIMF-F24-2 1492-XIMF-F120-2 1492-XIM24-16RF 20…26V DC 20…26V DC 20…26V DC 96…132V AC 20…26V DC 96…132V AC 20.30 x 3.30 x 3.27 x 2.. precede part number with the letter “W.30 x 3.27 x 2.26V DC 20.78 6. Current Dimensions (Per Circuit/ (Per Module) (W x H x D) (in..65 x 3. Number Voltage Range 1764-24AWA & 24BWA Max.15 x 3.27 x 2.27 x 2.27 x 2.65 x 3.26V DC 10/12 A 10/12 A 10/12 A 10/12 A 10/12 A 10/12 A 10/12 A 10/12 A 10/12 A 10/12 A 10/12 A 2/NA A 2/NA A 2/NA A 10/12 A 96 A 48 A 48 A 48 A 48 A 48 A 96 A 96 A 96 A 96 A 96 A 4A 4A 4A 96 A 9.78 6. Current Max.78 6.78 10.27 x 2.06 x 3..78 10.78 3.65 x 3. For spare part.27 x 2.. ➋ Ships with each module.19 2 mA 2 mA 2 mA 2 mA 2 mA 2 mA 2 mA 2 mA 2 mA 2 mA — 46006-222-01 46006-216-01 46006-216-01 46006-216-01 46006-217-01 46006-217-01 46006-223-01 46006-223-01 46006-223-01 46006-223-01 46006-223-01 46006-218-01 46006-218-01 46006-218-01 46006-219-01 3.65 x 3.) ➊ Per Relay Pair) Indicator Circuit Label Card Current Replacement Part (Nominal) Catalog Number ➋ 1492-XIM4024-16R.28 2 mA 11. multiply inches by 25.78 6. multiply inches by 25.. Current per IFM Module IFM Module Indicator Circuit Current NA NA NA Operating Ambient Temperature 0°C to 60°C 0°C to 60°C 0°C to 60°C 1492-IFM20F 1492-IFM20FN 1492-IFM20F-2 12 Amps 12 Amps 12 Amps Publication 1492-TD008D-EN-P .27 x 2.78 11.132V AC 20.27 x 2. To convert to millimeters.30 x 3.27 x 2 mA 2..” Quick Reference.132V AC 96.” 1764-24AWA and -24BWA Base Unit Output Current Ratings when using 1492-IFM20x Modules IFM Cat. precede part number with the letter “W. Current/Output using IFM 0…264V AC 10…125V DC 0…132V AC 10…125V DC 0…264V AC 10…125V DC (Out 0-Out 3) 2 Amps (Out 4-Out 11) 1 Amps (Out 0-Out 3) 2 Amps (Out 4-Out 11) 1 Amps (Out 0-Out 3) 2 Amps (Out 4-Out 11) 1 Amps Max..27 x 2.4.78 2 mA 6.4. -RXIM402416R 1492-XIM4024-8R 1492-XIM2024-8R 1492-XIM20120-8R 1492-XIM24-8R.26V DC 0…132V AC/DC 10…30V DC 85…132V AC 20..78 ➊Dimensions are in inches.27 x 2.27 x 2.27 x 2.30 x 3.Digital/Analog Programmable Controller Wiring Systems 189 ➊ Dimensions are in inches.28 2 mA 3.78 10...15 x 3. Current per IFM Module IFM Module Indicator Circuit Current NA Operating Ambient Temperature 0…132V AC 1492-IFM40F 10…125VD C 24V DC 0…264V AC 1492-IFM40F-2 10…125V DC 24V DC Note: For inputs use standard 2 A/circuit ratings. Current per -L40BWA max. IFM Module Current/Output using IFM (Out 0-Out 3) 2 Amps (Out 4-Out 15) 1 Amps (Out 0-Out 3) 2 Amps (Out 4-Out 15) 1 Amps 12 Amps 12 Amps IFM Module Indicator Circuit Current NA NA Operating Ambient Temperature 0°C to 60°C 0°C to 60°C 1492-IFM40F 1492-IFM40F-2 0…132V AC 10…125V DC 0…264V AC 10…125V DC Note: For inputs use standard 2 A/circuit ratings.10.5 AMP (Out 0-Out 1) 2 AMP (Out 8-Out 11) 1 AMP (Out 2-Out 7) 0.11) 2 AMP (Out 12-Out 15) 1 AMP (Out 2-Out 9) 0. Number Voltage Range 1762-L40AWA & Max.190 Digital/Analog Programmable Controller Wiring Systems Note: For inputs use standard 2 A/circuit ratings 1764-28BXB Base Unit Output Current Ratings when using 1492-IFM20x Modules IFM Cat. Current/Output using IFM Max.5 AMP (Out 0-Out 1) 2 AMP (Out 8-Out 11) 1 AMP (Out 2-Out 7) 0.5 AMP 12 Amps NA 0°C to 60°C 12 Amps NA 0°C to 60°C 12 Amps NA 0°C to 60°C IFM Module Indicator Circuit Current Operating Ambient Temperature 0…264V AC 1492-IFM20F 10…125V DC 24V DC 0…132V AC 1492-IFM20FN 10…125V DC 24V DC 0…264V AC 1492-IFM20F-2 10…125V DC 24V DC Note: For inputs use standard 2 A/circuit ratings 1762-L40AWA and -L40BWA Base Unit Output Current Ratings when using 1492-IFM40x Module IFM Cat. (Out 0.5 AMP (Out 0.January 2009 . Current per Current/Output using IFM IFM Module (Out 0-Out 1) 2 AMP (Out 8-Out 11) 1 AMP (Out 2-Out 7) 0. 1762-L40BXB Output Current Ratings when using 1492-IFM40x Modules IFM Cat. Number Voltage Range 1762-L40BXB Max. Number Voltage Range 1764-2BXB Max. Max.5 AMP 12 Amps NA 0°C to 60°C 12 Amps 0°C to 60°C Publication 1492-TD008D-EN-P .10.11) 2 AMP (Out 12-Out 15) 1 AMP (Out 2-Out 9) 0.1.1. except for occasional temporary conductivity caused by condensation shall be expected.January 2009 . (7..2 . ➋ Pollution Degree 2 is an environment where normally only non-conduction pollution occurs. NRAQ Agency Certification Modules CE Certifications Maximum Peak Transient Voltage Terminal Block Wire Range (Rated Cross Section) Factory Mutual (FM): Hazardous Locations..2 .0.0.3000590 Compliant for all applicable directives 600V ➊ Fixed Screw Style: #12…#22 AWG (4..32 in.2 .. 1.12 AWG Solid Wire Stranded Wire Ferrule Ferrule w/ plastic collar 0.5 lb-in.Digital/Analog Programmable Controller Wiring Systems 191 General Wiring System Specifications Parameter Agency Certifications: Modules and Cables Specifications cULus: Hazardous Locations. Class I Di v 2 (all except modules with relays).28 in.38…0.0 mm) Fixed Screw Style: 3. 2. (10.Solid wire: actuator not required . NRAG cULus: Ordinary Locations. of Wires per Terminal ➊ 3 #20 3 #18 3 #16 2 #14 1 #12 1 ➊ Maximum number of the same gauge of wire stranded copper conductors allowed per wire funnel Figure 1 — Push-in RTB Plug Specifications Single wire per pole (except by using a ferrule) For Insertion . UL File E113724.5 mm2) Removable Push-in Style: #12 to #26 AWG (2.5 mm 0. Groups A. Module with relays. and D. No.38…0.5.50 Nm) Removable Push-in Style: NA (See Figure 1) 0…+60°C 5% to 95% non-condensing -20…+80°C -40…+85°C 2➋ Wire Strip Length Recommended Terminal Block Screw Torque Operating Temperature Range Operating Humidity Storage Temperature Cables Storage Temperature Modules Pollution Degree ➊ For transients > 600V use a UL Recognized suppression device rated at 2. Fixed Screw Style Terminal Block Max. UL File E10314...0 mm) Removable Push-in Style:.2 . FM file J.5 kV withstand.Stranded wire: actuator required For Removal ..I.5 mm 0.0 mm) Removable Screw Style:.5…4. Class I Div 2 (all modules. B. (8.2 mm2) Removable Screw Style: #12 to #22 AWG 2..5 mm 2 2 2 2 0. 2.5 mm Publication 1492-TD008D-EN-P .2mm2) Fixed Screw Style:. C..50 Nm) Removable Screw Style: 3. AWG #22 Max.39 in.0. C. and D... Groups A.. except those with relays)..0.Solid or stranded wire: actuator required Clamp Range: AWG conductor: 26. Guide No..5 lb-in. Guide No.5. B. (0. Temperature Code T3C @ 60°C. (0.. 2. Temperature Rating: T3C @ 60°C..5…4. 1 A B300 Pilot duty. 1 CO.55 kW 1-phase 24VDC DC-13. 5. 700-HK36___ ➋ Rated Thermal Current (Ith) 1-pole. 16 A ➊ 277VAC 16A General use ➊ 30VDC DC-1.1 A R300 Pilot duty. 12 A 10 A. 3.22 A 250VDC DC-13. No.192 Maximum Switching Capacity Relay Contact Rating Electrical Ratings: Cat. 300V UL/CSA ➊ AC-15. and Continuous Minimum Permissible Contact Rating ➊ Maximum module current: ➋ Replacement relays: -10 Amp per relay output -12 Amps per 2 adjacent relay outputs -24V DC control (coil) voltage (Cat.4 .16 A ➊ Rated Thermal Current (UI) Electrical Ratings of Contacts Inductive VAC 250V IEC.5A 3/4 Hp (0. No.24 kW) 1-phase 240VAC AC-15. 0.January 2009 Cycles Resistive load .2 A B300 Pilot duty. 700-HK36 SPDT Electrical Life (AC Loads) vs.0 A 125VDC DC-13. 0.2 A R300 Pilot Duty. No. 1. Resistive 300 mW (5V/60 mA or 60V/5 mA) for silver contacts 120VAC Inductive VDC Resistive Make.cos = 0. SPDT . 0. Break.11 A 23VAC AC-1. 6. 700-HK36A1) Bul.55 kW) 1-phase 230VAC 0. 3 A 1/3 Hp (0. 0. Contact Life Publication 1492-TD008D-EN-P .cos = 1 Inductive load . 700-HK36Z24) -120V AC control (coil) voltage (Cat. Note: The release time for the load will be increased. the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load. Contact Life 20. • Publication 1492-TD008D-EN-P .0 2.January 2009 . 700-HK36 Maximum DC1 Breaking Capacity Electrical Life (DC Loads) vs.2 20 60 140 100 DC Voltage [V] 180 220 • When switching a resistive load (DC1) having voltage and current values under the curve.0 6.0 DC Breaking Current [A] 10.0 Resistive Load 0.0 4. In case of inductive loads (DC13).193 Bul.0 1. an electrical life of ≥ 100 x 103 can be expected. January 2009 .194 Publication 1492-TD008D-EN-P . . Printed in USA. All Rights Reserved. . Inc.Publication 1492-TD008D-EN-P — January 2009 Supercedes Publication 1492-TD008C-EN-P — September 2005 Copyright ©2009 Rockwell Automation.
Copyright © 2024 DOKUMEN.SITE Inc.