77High performance steel anchors High performance steel anchors Zykon anchor FZA...................................................... page 79 Anchor bolt FAZ II. ...................................................... page 086 Setting tool FABS....................................................... page 090 Torque Wrench........................................................... page 091 Zykon hammerset anchor FZEA II. ............................. page 092 Through Bolt FA......................................................... page 094 Bolt FH II.................................................................... page 095 Multi-bolt FMB............................................................ page 099 Heavy-duty anchor TA M............................................ page 100 Bolt FBN II.................................................................. page 103 Concrete screw FBS.................................................. page 108 Hollow-ceiling anchor FHY..........................................page 111 Sleeve anchor FSA. ................................................... page 113 Sleeve anchor FSA GB............................................. page 115 Express anchor EXA.................................................. page 117 Wallbolt GM................................................................ page 121 Wallbolt FWB . ........................................................... page 123 Hammerset anchor EA II............................................ page 125 TL Drop-in anchor. ..................................................... page 128 FDAR. ........................................................................ page 129 Ceiling nail FDN......................................................... page 130 Nail anchor FNA II...................................................... page 131 Heavy-duty anchor SL M............................................ page 134 Wall screw MR. ........................................................... page 136 Fixing Set for diamond drills FDBB............................ page 137 78 For heavy duty applications, fischer offers a wide range of technically advanced steel anchors. For general, non safety-critical applications, anchors such as the FSA and TA M, expansion bolts like the FBN II and drop-in anchors such as the EAII Hammerset can be offered. The range also includes a choice of wallbolts - GM or FWB - for a reliable fix. For structuraly demanding applications, we can offer a large range of products which carry the ETA Approval - Option 1 and can be used where safety and reliability are paramount. The fischer heavy duty sleeve anchor FH II is the solution for structurally demanding applications as it has the highest tensile and shear loads for push-through installations. European Technical Approval (Option 1) for cracked and non-cracked concrete. The fischer FBN II anchor offers maximum load-bearing capacity in non-cracked concrete. European Technical Approval (Option 7) for non-cracked concrete. The fischer FSA is a lightweight sleeve anchor for non structural and non safety critical push through applications. High performance steel anchors Market Perception / Cost FH II BEST FAZ II FBN II BETTER GOOD FSA Product Performance 79 Zykon anchor FZA OVERVIEW Zykon Bolt anchor FZA, zinc-plated steel Zykon Internallythreaded anchor FZA-I, zinc-plated steel Zykon Through anchor FZA-D, zinc-plated steel Zykon Bolt anchor FZA A4 resp. FZA C Zykon Through anchor FZA-D A4 resp. FZA-D C Zykon Internallythreaded anchor FZA-I A4 stainless steel resp. high corrosion-resistant steel (material 1.4529) Approved for: ▪ Cracked and non-cracked concrete B25 to B55 resp. C20/25 to C50/60 Also suitable for: ▪ Concrete B15 resp. C12/15 ▪ Natural stone with dense structure ▪ Solid brick ▪ Solid sand-lime brick For fixing of: ▪ Steel constructions ▪ Railings ▪ Consoles ▪ Ladders ▪ Cable trays ▪ Machines ▪ Staircases ▪ Gates ▪ Facades ▪ Window elements from size M8 Description ▪ Undercut anchor for pre-positioned (FZA bolt version and internally-threaded anchor FZA-I) and push-through installation (FZA-D bolt version). ▪ A cylindrical conical hole with an undercut is produced with the Drill bit FZUB in one work process. ▪ When setting the anchor, the anchor sleeve is driven over the cone with a hammer (or setting tool) and fills the undercut hole with a positive fit. ▪ Also available: special version FZA ST A4 for man hole step irons according to DIN V 1211 GS / 1212 GS. ▪ A4 stainless steel version for outdoor use and in damp conditions, highly corrosion-resistant steel C (material no. 1.4529) for applications in aggressive atmospheres. Advantages/benefits ▪ Positive fit in the undercut gives additional safety. ▪ Virtually expansion-free operation allows cost-efficient fixing with very small edge distances and axial spacings. ▪ Single-step drilling process simultaneously produces the undercut, saving installation time. ▪ Green ring becomes visable when correctly set. ▪ Immediate load-bearing capability avoids installation interruptions (no interruption for resin curing times, unlike chemical anchors). ▪ Anchor version with internal thread for high flexibility by using threaded rods or screws of different lengths and type. INSTALLATION ▪ Pre-positioned installation (FZA and FZA-I) ▪ Push-through installation (FZA-D), please note: drill through the fixture STANDARDS Type of installation You will find everything that has standards on page 313 under the keyword approvals. High performance steel anchors The powerful and safe undercut anchor bolt for the cracked or tension zone. zinc-plated steel Type Art. ID approval ■ ETA drill-Ø do [mm] anchorage depth hef [mm] max. qty. stainless steel A4 Type Art. . FIRE PROTECTION CORROSION Red hot: see page 308 for information about fire protection. qty. ID approval ■ ETA drill-Ø do [mm] anchorage depth hef [mm] max. per box FZA 10 x 40 M 6/10 A4 FZA 10 x 40 M 6/35 A4 FZA 12 x 40 M 8/15 A4 FZA 12 x 50 M 8/15 A4 FZA 12 x 50 M 8/50 A4 FZA 14 x 40 M10/25 A4 FZA 14 x 60 M10/25 A4 FZA 14 x 60 M10/50 A4 FZA 18 x 80 M12/25 A4 FZA 18 x 80 M12/55 A4 FZA 22 x 100 M16/60 A4 FZA 22 x 125 M16/60 A4 60772 60771 60775 60776 60774 60778 60779 60766 60781 60767 60782 60768 5 8 6 3 9 7 4 4 7 1 4 8 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 10 10 12 12 12 14 14 14 18 18 22 22 40 40 40 50 50 40 60 60 80 80 100 125 10 35 15 15 50 25 25 50 25 55 60 60 M6 M6 M8 M8 M8 M 10 M 10 M 10 M 12 M 12 M 16 M 16 10 10 13 13 13 17 17 17 19 19 24 24 25 25 25 20 20 20 10 10 10 10 10 6 Zykon Bolt Anchor FZA C.80 Zykon anchor FZA High performance steel anchors Technical DATA Zykon Bolt anchor FZA. per box FZA 10 x 40 M 6/10 C FZA 10 x 40 M 6/35 C FZA 12 x 40 M 8/15 C FZA 12 x 50 M 8/15 C FZA 12 x 50 M 8/50 C FZA 14 x 40 M10/25 C FZA 14 x 60 M10/25 C FZA 14 x 60 M10/50 C FZA 18 x 80 M12/25 C FZA 18 x 80 M12/55 C FZA 22 x 100 M16/25 C FZA 22 x 100 M16/30 C FZA 22 x 100 M16/60 C FZA 22 x 125 M16/60 C 96214 96361 96215 96227 96362 96228 96216 96358 96315 96359 33800 24523 96364 96360 5 6 2 5 3 2 9 6 9 3 1 1 7 9 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 10 10 12 12 12 14 14 14 18 18 22 22 22 22 40 40 40 50 50 40 60 60 80 80 100 100 100 125 10 35 15 15 50 25 25 50 25 55 25 30 60 60 M6 M6 M8 M8 M8 M 10 M 10 M 10 M 12 M 12 M 16 M 16 M 16 M 16 10 10 13 13 13 17 17 17 19 19 24 24 24 24 25 25 25 20 20 25 10 10 10 10 10 10 10 6 Other usable lengths available on request..-No. ID approval ■ ETA drill-Ø do [mm] anchorage depth hef [mm] max. usable length t fix [mm] thread M width across nut SW pcs. per box FZA 10 x 40 M 6/10 FZA 12 x 40 M 8/15 FZA 12 x 50 M 8/15 FZA 14 x 40 M10/25 FZA 14 x 60 M10/25 FZA 18 x 80 M12/25 FZA 22 x 100 M16/60 FZA 22 x 125 M16/60 60712 60715 60716 60718 60719 60721 60724 60725 1 2 9 3 0 3 4 1 ■ ■ ■ ■ ■ ■ ■ ■ 10 12 12 14 14 18 22 22 40 40 50 40 60 80 100 125 10 15 15 25 25 25 60 60 M6 M8 M8 M 10 M 10 M 12 M 16 M 16 10 13 13 17 17 19 24 24 25 25 20 25 10 10 10 6 Zykon Bolt anchor FZA A4. All about corrosion and how you can avoid it is written on page 309. high corrosion-resistant steel 1.-No.4529 Type Art. usable length t fix [mm] thread M width across nut SW pcs. usable length t fix [mm] thread M width across nut SW pcs. qty.-No. per box FZA 12 x 50 M 8 D/10 A4 FZA 12 x 60 M 8 D/10 A4 FZA 12 x 80 M 8 D/30 A4 FZA 14 x 80 M10 D/20 A4 FZA 14 x 100 M10 D/40 A4 FZA 18 x 100 M12 D/20 A4 FZA 18 x 130 M12 D/50 A4 FZA 22 x 125 M16 D/25 A4 60664 60665 60666 60669 60670 60672 60673 60675 3 0 7 8 4 8 5 9 ■ ■ ■ ■ ■ ■ ■ ■ 12 12 12 14 14 18 18 22 40 50 50 60 60 80 80 100 10 10 30 20 40 20 50 25 M8 M8 M8 M 10 M 10 M 12 M 12 M 16 13 13 13 17 17 19 19 24 25 25 25 10 10 10 10 10 Other usable lengths available on request. bolt penetration qty. ID approval ■ ETA drill-Ø do [mm] anchorage depth hef [mm] internal thread ds min. zinc-plated steel Type Art. Zykon Through anchor FZA-D C.81 Technical DATA Zykon Through anchor FZA-D. FZA 12 x 40 M 6 I FZA 14 x 60 M 8 I FZA 18 x 80 M10 I FZA 22 x 100 M12 I FZA 22 x 125 M12 I 60758 60760 60761 60763 60769 9 2 9 3 5 ■ ■ ■ ■ ■ 12 14 18 22 22 40 60 80 100 125 M6 M8 M 10 M 12 M 12 8 11 13 15 15 13 17 21 25 25 25 20 10 10 10 High performance steel anchors . per box FZA 12 x 50 M 8 D/10 FZA 12 x 60 M 8 D/10 FZA 12 x 80 M 8 D/30 FZA 14 x 80 M10 D/20 FZA 14 x 100 M10 D/40 FZA 18 x 100 M12 D/20 FZA 18 x 130 M12 D/50 FZA 22 x 125 M16 D/25 60652 60653 60654 60657 60658 60684 60685 60663 0 7 4 5 2 1 8 6 ■ ■ ■ ■ ■ ■ ■ ■ 12 12 12 14 14 18 18 22 40 50 50 60 60 80 80 100 10 10 30 20 40 20 50 25 M8 M8 M8 M 10 M 10 M 12 M 12 M 16 13 13 13 17 17 19 19 24 25 25 25 10 10 10 10 10 Other usable lengths available on request. ID approval ■ ETA drill-Ø do [mm] anchorage depth hef [mm] max.-No. per box e2 [mm] e1 [mm] pcs.-No. qty. qty. high corrosion-resistant steel 1. per box FZA 12 x 50 M 8 D/10 C FZA 12 x 60 M 8 D/10 C FZA 12 x 80 M 8 D/30 C FZA 14 x 80 M10 D/20 C FZA 18 x 100 M12 D/20 C FZA 18 x 130 M12 D/50 C 96319 96353 96354 96355 96356 96357 7 1 8 5 2 9 ■ ■ ■ ■ ■ ■ 12 12 12 14 18 18 40 50 50 60 80 80 10 10 30 20 20 50 M8 M8 M8 M 10 M 12 M 12 13 13 13 17 19 19 20 20 20 10 10 10 Other usable lengths available on request. stainless steel A4 Type Art. ID approval ■ ETA drill-Ø do [mm] anchorage depth hef [mm] max. bolt penetration max. qty.-No. Technical DATA ZyKON INTERNALLY-THREADED ANCHOR Zykon Internally-threaded anchor FZA-I. ID approval ■ ETA drill-Ø do [mm] anchorage depth hef [mm] max. Zykon Through anchor FZA-D A4.4529 Type Art.-No. usable length t fix [mm] thread M width across nut SW pcs. usable length t fix [mm] thread M width across nut SW pcs. zinc-plated steel Type Art. usable length t fix [mm] thread M width across nut SW pcs. . M10 I FZA 22 x . DRILLING AND SETTING TOOLS Drill bit FZUB approved only for Zykon anchors and Zykon hammerset anchors Type Art..... M10 D FZA 18 x ..... M12 FZA 22 x . M10 FZA 18 x . ID approval ■ ETA drill-Ø do [mm] anchorage depth hef [mm] internal thread ds min. M12 D FZA 22 x ..... bolt penetration max.... per box e2 [mm] e1 [mm] pcs..M12 D – FZA 12 x . M10 FZA 18 x . M16 Through anchor – – FZA 12 x 50 M8 D/10 FZA 12 x 60 M8 D/10 FZA 12 x 80 M8 D/30 – – FZA 14 x 80 M10 D/20 FZA 14 x 100 M10 D/40 – FZA 18 x 100 M12 D/20 FZA 18 x 130 M12 D/50 – FZA 22 x 125 M16 D/25 – FZA 12 x .. M6 I FZA 14 x . bolt penetration qty.. usable length t fix [mm] thread M width across nut SW pcs.M8 D FZA 14 x . qty. M16 D Internally-threaded anchor – FZA 12 x 40 M6 I FZA 12 x 50 M6 I – – – FZA 14 x 60 M8 I – – FZA 18 x 80 M10 I – – FZA 22 x 100 M12 I FZA 22 x 125 M12 I – – – – – FZA 12 x ..-No.. M12 I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 CORROSION All about corrosion and how you can avoid it is written on page 309. stainless steel A4 Type Art.. M8 FZA 14 x .. ID Machine setting tool FZUE for mounting on the drill bit Setting tool FZE Including centring pin for internally-threaded anchors for assembly with hand hammer qty... M12 FZA 10 x 40 M6/35 FZA 12 x ... per box FZA 14 x 40 ST A4 FZA 14 x 60 ST A4 1) 1) 60686 60687 5 2 14 14 40 60 30 30 M 10 M 10 16 16 20 20 1) According to DIN V 1211GS/1212GS. M8 FZA 14 x . fits anchor Bolt anchor FZUB 10 x 40 FZUB 12 x 40 FZUB 12 x 50 FZUB 12 x 60 FZUB 12 x 80 FZUB 14 x 40 FZUB 14 x 60 FZUB 14 x 80 FZUB 14 x 100 FZUB 18 x 80 FZUB 18 x 100 FZUB 18 x 130 FZUB 22 x 100 FZUB 22 x 125 FZUE 10 FZUE 12 FZUE 14 FZUE 18 FZE 10 FZE 12 Plus FZE 14 Plus FZE 18 Plus FZE 22 Plus 60622 60623 60627 60625 60626 60624 60628 60629 60630 60634 60632 60633 60636 60638 60640 60641 60642 60643 60740 44638 44639 44640 44641 3 0 8 4 1 7 5 2 8 6 2 9 0 4 7 4 1 8 4 1 8 5 2 FZA 10 x 40 M6 FZA 12 x 40 M8 FZA 12 x 50 M8 – – FZA 14 x 40 M10 FZA 14 x 60 M10 – – FZA 18 x 80 M12 – – FZA 22 x 100 M16 FZA 22 x 125 M16 FZA 10 x 40 M6/10 FZA 12 x ..... per box pcs.82 Zykon anchor FZA High performance steel anchors Technical DATA ZyKON INTERNALLY-THREADED ANCHOR Zykon internally-threaded anchor FZA-I A4.M10 D FZA 18 x ... M8 I FZA 18 x . FZA 12 x 40 M 6 I A4 FZA 12 x 50 M 6 I A4 FZA 14 x 60 M 8 I A4 FZA 18 x 80 M10 I A4 FZA 22 x 100 M12 I A4 FZA 22 x 125 M12 I A4 60783 60784 60786 60787 60788 60770 1 8 2 9 6 1 ■ ■ ■ ■ ■ ■ 12 12 14 18 22 22 40 50 60 80 100 125 M6 M6 M8 M 10 M 12 M 12 8 8 11 13 15 15 13 13 17 21 25 25 25 25 20 10 10 10 Technical DATA ZyKON ANCHOR FOR FIXING MAN HOLE STEP IRONS Zykon anchor for fixing man hole step irons FZA ST A4 Type Art. ID drill-Ø do [mm] anchorage depth hef [mm] max... .. M8 D FZA 14 x .-No.-No. 9 29.4 9.4 132.6 3.0 15.4 7.3 12.4* 17.9 18.0 12.1 6.2 17.2 18. The conditions of application may differ from those given in the European Technical Approval.2 12.9 7.2 35.4 6.0 8.0 24.9 19.5 16.1 12.0 12.5 15.3 44.8 40.9 18.4 132.5 8.0 27.6 5.6 4.6 5.1 12.4 26.0 41.4 9.2 17.0 15.3 25.5 50.7 4.0 16.3 13.3 11.4* 6.9 70 70 100 20 16.6 3.0 75.1 17.4 26.6 12.9 100 100 200 100 66.0 36.9 29.2 8.9 7.9 70 70 100 20 23.9 23.5 12.2 5.0 15.0 12.7 51.8* 24.6 5.9 100 100 200 100 94.4 132.1 17.4 35.1 23.0 13.3 44.3 8.1 13.9 29.6 18.3 13.4 are included.1 23.4* 65.4 5.1 106.9 25.0 8.7 6.5 6.4 152.2 10.3 11.0 35. Design resistant loads: material safety factor γM is included.1 7.4 132. edge distance the above described loads have to be reduced! (See “Technical Handbook” or design software “CC-Compufix”) All load values apply for concrete C20/25 without edge or spacing influence.2 6.1 6.3 17.1 6.2 4.0 50 45 100 20 22.1 A4 4.6 34.0 17.3 13.4 11.0 18.3 44.2 17.1* gvz 9.0 C 6.0 24.9 7.9* 33.2 35.9 7.1 12.1 13.9 4. edge distance 1) Min. design resistant and recommended loads for single anchors of fischer Zykon bolt anchor FZA with large axial spacing and edge distance Anchor size Effective anchorage depth Drill hole depth Drill hole diameter Mean ultimate loads Nu and Vu [kN] Tensile Shear gvz 16.2 9.0 8.0 15.0 16.3 4.4 26.2 11.9 36.2 17.8* 24.7 6.1 11.4* 17.ZYKON BOLT Anchor Mean ultimate loads.6 6.5* 35.9 35.0 22.4 152.3 5.0 35.0 26.8* 24.0 40 40 100 20 12. High performance steel anchors . structural component thickness hmin [mm] 100 100 Required torque T inst [Nm] 8.0 17.9 23.3 75.2 75.3 4.4* 11.1 27.3 4.5 33.2 12.7 5.7 7.5 75.3 9.3 12.0 Component dimensions.5 8.6 5.6 13.1 40 35 100 8.6* 15.9 5.0 66.9 25. Recommended loads: material safety factor γM and safety factor for load γL = 1.1* A4/C 14.4 152.4* 9.4* 6.2 6.0 50.6 13.0 48.6 34.8 33.3 9.3 9.4 4.3 44.9 7.1 23. axial spacing1) smin [mm] 40 40 cmin [mm] 35 40 Min.1 34.0 37.1 6.9 60 55 120 40 33.2 35.0 7.4* 65.1 106.2 31.6 34.9 7.9 23.8 8.5 15.0 15.7 7.1 17.4* 65.7 6.9* 37.3 4.3 19.2 47.4 9.2 10.9 7.5 20 Mrec [Nm] * steel failure decisive 1) For min.2 31.0 41.4* 65.1 6.4* 13.3 40.0 18.6* 15.4 80 70 160 60 67.9* 24.1 6.9 36.5* 35.7 6.5 16.5 9.9 60.0 17.1 7.5 33.3 12.4* 8.4* 9.2 7.1 23.1 17.6* 90° Vu [kN] A4/C 8.4* 26.1 15.7 17.2 18.2 27.4 26.2 31.9 125 125 250 100 12.2 11. axial spacing and min.3 94.2 4.3 9.4 27.4 6.2 10. Material safety factor γM depends on type of anchor.3 4.6 17.9 60 55 120 40 48.1 6.83 LOADS .9 4.9 6.9 29.7 16.1 6.6* 8.5 11.4 27.0 4.7 50.4* 0° Nu [kN] gvz A4 C gvz A4 C gvz A4 C gvz A4 C 9.9 52.4 152.9 25.3 12.4 80 70 160 60 47.4 31.9 17.9 12.4 12.4 4.0 37.1 6.1 17.1 106.8 8.2 31.9 52.3 4.7 51.4 9.0 24.9 125 125 250 100 hef [mm] h0 [mm] d0 [mm] Non-cracked concrete Cracked concrete 10 x 40 12 x 40 14 x 40 12 x 50 14 x 60 18 x 80 22 x 100 22 x 125 10 x 40 12 x 40 14 x 40 12 x 50 14 x 60 18 x 80 22 x 100 22 x 125 M6 M8 M10 M8 M10 M12 M16 M16 M6 M8 M10 M8 M10 M12 M16 M16 40 40 40 50 60 80 100 125 40 40 40 50 60 80 100 125 43 44 45 54 65 85 105 130 43 44 45 54 65 85 105 130 10 12 14 12 14 18 22 22 10 12 14 12 14 18 22 22 Design resistant loads NRd and VRd [kN] Tensile 0° NRd [kN] Shear 90° VRd [kN] Recommended loads Nrec and Vrec [kN] Tensile 0° Nrec [kN] Shear 90° Vrec [kN] Recommended bending moment Mrec [Nm] gvz 7.2 34.9* 51.0 9.0 24.2 17. minimum axial spacings and edge distances Min.5 5.1 7.2 6.0 24.3 48.9 60.5 5.6* 15.1 106.3 4. For further detailed information about ETA please contact your local fischer representative.5 67.2 7.3 17.0 50 45 100 20 31.2 12.3 5. 3 92.5 85.2 17.2* 17.1 35.2 41.9 11.0 11.0 24.2 22.2 17.8 33.0 15.0 — 60.6* 34. edge distance 1) Min.2 17.0 22.2 9.1 7.9 57.6 — 100 100 200 100 12.1 17.6 5.5 17.1 50 45 100 20 22.1 13.4 80 70 160 60 33.2 17.1 13.6 — 100 100 200 100 hef [mm] h0 [mm] d0 [mm] Non-cracked concrete Cracked concrete 12 x 50 12 x 60 12 x 80 14 x 80 14 x 100 18 x 100 18 x 130 22 x 125 12 x 50 12 x 60 12 x 80 14 x 80 14 x 100 18 x 100 18 x 130 22 x 125 M8 D M8 D M8 D M10 D M10 D M12 D M12 D M16 D M8 D M8 D M8 D M10 D M10 D M12 D M12 D M16 D 40 50 50 60 60 80 80 100 40 50 50 60 60 80 80 100 44 54 55 65 65 85 85 105 44 54 55 65 65 85 85 105 12 12 14 14 14 18 18 22 12 12 14 14 14 18 18 22 Design resistant loads NRd and VRd [kN] Tensile 0° NRd [kN] Shear 90° VRd [kN] Recommended loads Nrec and Vrec [kN] Tensile 0° Nrec [kN] Shear 90° Vrec [kN] Recommended bending moment Mrec [Nm] gvz 52.2* 26. design resistant and recommended loads for single anchors of fischer Zykon Through-anchor FZA-D with large axial spacing and edge distance Anchor size Effective anchorage depth Drill hole depth Drill hole diameter Mean ultimate loads Nu and Vu [kN] Tensile Shear gvz 17.3 24.4 26.3 5. Material safety factor γM depends on type of anchor.7 22.3 12.1 6.0 12.7 8.4 37.4 37.9 7.9 23.1 6.8 16.3 20.0 11.1* 56.2 11.2 17.3 — 332.1 6.5 17.9 7.3 53.3 — 8.7 21.2 23.1* 56.0 11.9 18.0 11.8 31.0 22.0 8.9 11.9 7.2 9.2 34.9 26.1 13.3 12.9 18.8 28.9 — 60 55 120 40 48.5 17.3 12.3 16.6 5.2 85.ZYKON THROUGH Anchor Mean ultimate loads.5 85.9 116.8 31.5* 11.0 — 60.6 — 85.2 11.7 6.6* 34.3 24.9 7.2 52.4 26.1* 56.0 8.0 6.0 8.7 8.5* 24.3* 85. Recommended loads: material safety factor γM and safety factor for load γL = 1.9 116.2 8.1 174.3 9.0 37.7 45.5 6.9 52.1 — 26.1 35. structural component thickness hmin [mm] 100 100 Required torque T inst [Nm] 20 20 Mrec [Nm] * steel failure decisive 1) For min.7 16.8 53.7 22.3 12.7 45.8 52.2 17.3 12.0 33.1 7.4 80 70 160 60 48.9 116.5 8.5 67.1 17.7 16.3 29.1 C 35.1 13.4 9.3* 85.7 22.3 — 17.1 7.0 12.1 35.0 33.0 12.3 4.0 24.8 53.3 20.4 — 43.7 45.0 18.9 4.4 26.4 80 70 160 60 67.1 28.6* 34.1 gvz 23.6 14.4 9.5* 11.5 17.3 — 12.2 23.4* 13.3 48.8 A4 28.9 23.3 4.2 — 23.5 8.6* 34.7 45.2* 26. edge distance the above described loads have to be reduced! (See “Technical Handbook” or design software “CC-Compufix”) All load values apply for concrete C20/25 without edge or spacing influence.4 12.7 8.3 16.1 174.1 — 34.8* 25.1 40 40 100 20 16.1 50 45 100 20 31.2* 17.8 28.9 23.0 — 15.5 8.6 14.4 33.1* 56.5 85.1 8.4 14.3 12.2 10.6 52.9 26.3 — 332.3 8.1 50 45 100 20 16. The conditions of application may differ from those given in the European Technical Approval.5 11.5 11.3 48.1 35.1 6.4 14.2 11.0 11.2 6.9 116.9 7.4 12. For further detailed information about ETA please contact your local representative.5* 17.7 21.2 34.4 33.6 — 85.4 26.8 28.3 53.3 24.4 80 70 160 60 47.3 12.7 8.1 35.1 174.3 12.1 Component dimensions.8* 25.7 23.3 12.1 174.0 18.2 11.3 9.3 17.0 24.0 6.0 11.1 17.1 6.0 15.8 31.2 — 22.3 9.7 22.0 29.2 17.5 8.9 18.4 31.8 28.3 92.5 15.7 21.5* 37.9 7.9 23.7 21.9 — 60 55 120 40 33.8 31.1 178.8 16.9 52.3 92.4* 13.7 6. axial spacing and min.1 8.2 60 55 120 40 31.2 60 55 120 40 22.9 18.1 — 17.3 12.84 Zykon anchor FZA High performance steel anchors LOADS . minimum axial spacings and edge distances Min.3 9.4 31.0 11.2 47.2 10.4 26. axial spacing1) smin [mm] 40 50 cmin [mm] 40 45 Min. Design resistant loads: material safety factor γM is included.3 24.4 are included.1 A4/C 17.8 33.3 92.1 6.0 11.5* 17.8* 90° Vu [kN] A4/C 25.1 178.4* 0° Nu [kN] gvz A4 C gvz A4 C gvz A4 C gvz A4 C 9. .9 57.2 41. 7 17.5 18.2* 40.1 13. structural component thickness hmin [mm] Required torque T inst [Nm] [Nm] Recommended bending moment Mrec [Nm] Mrec * steel failure.5 — 4.4* — 7.2 12.1 3.7 4.5 12.7 22.5 29.9 80 70 160 30 47.4 25.4 4.1 5.9 7.5 17.1 5.8 5.2* 40.5 23.2* 40.5 — 13.5 18.1 43.5 4.0* 53.7 22.4* 31.9* 22.3 4.5 60 55 120 15 26.2 12.7* 27.5 21.5 17.2 — 5.9 7.9 80 70 160 30 63.7 44.0 24. 1) For min.1 40 35 100 8.4 — 3.0* 18.2 5.3 12.2 12.4* 24.0 9.85 LOADS .3 7.4 4.1 24.4* 31.5 — 4.5* 35.0 — 8.3 14. Design resistant loads: material safety factor γM is included.6* 15. values apply to screws with a strength classification 8.5 5.6 9.2* 13.0* 53.5 17.6 7.8* 24.1 43.5* 35. Recommended loads: material safety factor γM and safety factor for load γL = 1.4* 9.6 5. axial spacing1) smin [mm] Min.2 40.4* 13.4* 13.ZYKON InternalLY-THREADED Anchor Mean ultimate loads.9* 22.6 5.1 43. For further detailed information about ETA please contact your local representative.1 13.2 5.1 24.2 — 5.4* 11.5 6.5 21.4* — 7.3 4.1 50 45 100 8.1 9.6 7.5* 35.0 7. High performance steel anchors .3 14.0* 53.1 6. Material safety factor γM depends on type of anchor.0 18.6 125 125 250 60 hef h0 = d0 [mm] [mm] [mm] 12 x 40 M6 I 40 44 12 12 x 50 M6 I 50 54 12 Non-cracked concrete 14 x 60 18 x 80 22 x 100 22 x 125 M8 I M10 I M 12 I M12 I 60 80 100 125 65 85 105 130 14 18 22 22 12 x 40 M6 I 40 44 12 12 x 50 M6 I 50 54 12 Cracked concrete 14 x 60 18 x 80 M8 I M10 I 60 80 65 85 14 18 22 x 100 22 x 125 M12 I M12 I 100 125 105 130 22 22 Design resistant loads NRd and VRd [kN] Tensile Shear 0° 90° NRd VRd [kN] [kN] Recommended loads Nrec and Vrec [kN] Tensile Shear 0° Nrec [kN] [kN] 90° Vrec gvz A4 Component dimensions.1 13.1 17.5 18.4 7.0 5.7 44.2 12.6 100 100 200 60 63.1 40 35 100 8.7 44.9 7.5 — 12.0* 17.0 5. minimum axial spacings and edge distances Min.6 6.5 12.5 23. edge distance the above described loads have to be reduced! (See “Technical Handbook” or design software “CC-Compufix”) All load values apply for concrete C20/25 without edge or spacing influence.1 43.4 — 3.7* 27.0 9.2 47.4* 31.1 13.6* 8.5 29.5 17.2 9.5* 35.1 3. axial spacing and min.5 — 5. The conditions of application differ from those given in the European Technical Approval. edge distance 1) cmin [mm] Min.5 60 55 120 15 26.4* 6.4* 13.4* — 8.6 100 100 200 60 63.5 9.5 21.5 — 5.6 125 125 250 60 12.4 are included.9 7.7 4.0 12.1 5.4* 9.5 29.4 4.0* 18.7 5.6* 8.6 9.8 and A4-70 respectively.7 22. design resistant and recommended loads for single anchors of fischer Zykon internally-threaded anchor FZA-I with large axial spacing and edge distance Anchor size Effective anchorage depth Drill hole depth Drill hole diameter Mean ultimate loads Nu and Vu [kN] Tensile Shear 0° 90° Nu Vu [kN] [kN] gvz A4 gvz A4 gvz A4 gvz A4 gvz A4 gvz A4 17.4 25.1 50 45 100 8.8 5.7 44.6* 15.8* 24.3 12.5 9.6 6.0* 17.0 8. highly corrosionresistant steel 1. the tapered bolt is pulled into the expansion clip and expands it against the drill hole wall.4529) for applications in aggressive atmospheres. starting at 80 mm thickness ▪ Smallest edge distances and axial spacings for more application options ▪ Low driving-in energy. Highly corrosion-resistant steel (material number 1. ▪ Highest tensile and shear loads.86 Anchor bolt FAZ II The strong. The optimised shaft allows shear forces that are up to 96 % higher than those of the predecessor product.4529 from size M8 Description ▪ Anchor bolt for push-through installation. stainless steel A4 Approved for: ▪ Cracked and non-cracked concrete C20/25 to C50/60 Also suitable for: ▪ Concrete C12/15 ▪ Natural stone with dense structure For fixing of: ▪ Steel constructions ▪ Railings ▪ Consoles ▪ Ladders ▪ Cable trays ▪ Machines ▪ Staircases ▪ Gates ▪ Facades ▪ Window elements ▪ Wooden constructions Anchor bolt FAZ C. Advantages/benefits The unit of cone and expansion clip increases the tensile strength by up to 38 % in comparison to its predecessor and provides small edge distances and axial spacings. . ▪ The FAZ II made of stainless steel A4 is for outdoor applications and for damp rooms. FAZ II . zinc-plated steel Anchor bolt FAZ A4. as well as secure expansion. ▪ Optimised expansion clip ensures uniform load distribution for high permissible loads and small edge distances and axial spacings with structural elements. even in cracked concrete. ▪ When the hexagonal nut is tightened. With its optimised diameter. easy driving-in and a short tightening distance. it can be driven in easily and if necessary can also be aligned afterwards. that means: more safety with fewer total fixing points and thus lower costs ▪ Can be used in extremely thin concrete panels. easy-to-install expansion bolt for cracked concrete. ▪ Installation-friendly. ▪ FAZ-GS with large pre-assembled washer for fixings through oblong holes. High performance steel anchors OVERVIEW Anchor bolt FAZ II. small tightening distance and thus extremely handy for installation work ▪ High steel ductility enables subsequent alignment using a hammer STANDARDS You will find everything that has standards on page 313 under the keyword approvals.ADVANTAGES AT A GLANCE The black expansion clip makes the FAZ II easily distinguishable from its predecessor. since only a few revolutions are necessary to apply the torque. The distinctive collar ensures that the clip stays in its position even when reinforcements are hit or there are voids when it is driven in. 6 16 x 1.5 24 x 2. All about corrosion and how you can avoid it is written on page 309. the hexagon nut must be brought into the optimal installation position (the thread projects by 2 to 3 mm). ID approval drill-Ø min..5 24 x 2.5 30 x 3 30 x 3 30 x 3 30 x 3 30 x 3 30 x 3 30 x 3 24 x 2 24 x 2 25 x 3 25 x 3 30 x 3 30 x 3 30 x 3 56 x 5 56 x 5 50 50 50 25 20 50 25 25 20 20 20 20 20 20 20 20 20 20 20 10 10 10 10 10 10 10 10 50 50 50 25 20 20 20 10 10 FIRE PROTECTION CORROSION Red hot: see page 308 for information about fire protection. ▪ Before driving in. per box nut (outer diameter x thickness) SW [mm] pcs. zinc-plated steel Type Art. anchorage depth hef [mm] anchor length max.6 20 x 2 20 x 2 20 x 2 20 x 2 20 x 2 20 x 2 20 x 2 24 x 2. ■ ETA do [mm] l [mm] t fix [mm] M FAZ II 8/10 FAZ II 8/30 FAZ II 8/50 FAZ II 8/100 FAZ II 8/150 FAZ II 10/10 FAZ II 10/20 FAZ II 10/30 FAZ II 10/50 FAZ II 10/80 FAZ II 10/100 FAZ II 10/150 FAZ II 12/10 FAZ II 12/20 FAZ II 12/30 FAZ II 12/50 FAZ II 12/80 FAZ II 12/100 FAZ II 12/150 FAZ II 12/200 FAZ II 16/25 FAZ II 16/50 FAZ II 16/100 FAZ II 16/150 FAZ II 16/200 FAZ II 16/250 FAZ II 16/300 FAZ II 8/10 GS FAZ II 8/30 GS FAZ II 10/10 GS FAZ II 10/30 GS FAZ II 12/10 GS FAZ II 12/30 GS FAZ II 12/120 GS FAZ II 16/150 GS FAZ II 16/200 GS 1) GS = large washer 1) 1) 1) 1) 1) 1) 1) 1) 1) 94871 94877 94878 94879 94980 94981 94982 94983 94984 94985 94986 95141 95419 95420 95421 95446 95454 95470 95557 95605 95836 95864 95865 95875 95967 95968 96188 94872 96189 96291 96297 96303 96340 96367 96368 96370 2 4 1 8 1 8 5 2 9 6 3 5 5 1 8 1 6 6 4 2 0 3 0 9 1 8 9 9 6 6 8 6 1 8 5 8 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 8 8 8 8 8 10 10 10 10 10 10 10 12 12 12 12 12 12 12 12 16 16 16 16 16 16 16 8 8 10 10 12 12 12 16 16 75 95 115 165 215 90 100 110 130 160 180 230 105 115 125 145 175 195 245 295 140 165 215 265 315 365 415 75 95 90 110 105 125 215 265 315 45 45 45 45 45 60 60 60 60 60 60 60 70 70 70 70 70 70 70 70 85 85 85 85 85 85 85 45 45 60 60 70 70 70 85 85 77 97 117 167 217 95 105 115 135 165 185 235 110 120 130 150 180 200 250 300 150 175 225 275 325 375 425 77 97 95 115 110 130 220 275 325 10 30 50 100 150 10 20 30 50 80 100 150 10 20 30 50 80 100 150 200 25 50 100 150 200 250 300 10 30 10 30 10 30 120 150 200 M8 M8 M8 M8 M8 M 10 M 10 M 10 M 10 M 10 M 10 M 10 M 12 M 12 M 12 M 12 M 12 M 12 M 12 M 12 M 16 M 16 M 16 M 16 M 16 M 16 M 16 M8 M8 M 10 M 10 M 12 M 12 M 12 M 16 M 16 13 13 13 13 13 17 17 17 17 17 17 17 19 19 19 19 19 19 19 19 24 24 24 24 24 24 24 13 13 17 17 19 19 19 24 24 16 x 1.5 24 x 2.87 INSTALLATION Type of installation ▪ Push-through and pre-positioned installation Installation tips ▪ For large number of installations we recommend the anchor bolt setting tool FABS (see page 90) to reduce installation time.6 16 x 1. zinc-plated steel width across Washer qty.6 16 x 1.5 24 x 2.5 24 x 2. drill-hole depth for through fixings td [mm] effect.5 24 x 2. High performance steel anchors . Technical DATA Anchor bolt FAZ II. usable length thread Anchor bolt FAZ II-GS (with large washer).-No.5 24 x 2.6 16 x 1. FAZ II 20/30 FAZ II 20/60 FAZ II 20/150 FAZ II 24/30 FAZ II 24/60 46632 46633 46634 46635 46636 1 8 5 2 2 ■ ■ ■ ■ ■ 20 20 20 24 24 165 195 280 190 215 100 100 100 125 125 172 202 292 204 234 30 60 150 30 60 M 20 M 20 M 20 M 24 M 24 27 27 27 32 32 5 5 5 5 5 Anchor bolt FAZ A4.-No.-No.5 24 x 2.5 22 x 2.4529 width across Washer qty. ID approval drill-Ø min. highly corrosion-resistant steel 1.6 20 x 2 20 x 2 24 x 2. per box nut (outer diameter x thickness) SW [mm] pcs.5 24 x 2. zinc-plated steel Anchor bolt FAZ GS (with large washer). anchorage depth hef [mm] anchor length max. stainless steel A4 Type Art.5 30 x 3 30 x 3 30 x 3 37 x 3 44 x 4 22 x 2. ID approval drill-Ø min.6 16 x 1.5 25 x 3 25 x 3 30 x 3 30 x 3 16 x 1.6 16 x 1. drill-hole depth for through fixings td [mm] effect.6 16 x 1.6 16 x 1. usable length t fix [mm] thread width across nut qty. anchorage depth hef [mm] anchor length max. ■ ETA do [mm] l [mm] t fix [mm] M FAZ 8/10 A4 FAZ 8/30 A4 FAZ 8/50 A4 FAZ 10/10 A4 FAZ 10/20 A4 FAZ 10/30 A4 FAZ 10/50 A4 FAZ 10/70 A4 FAZ 10/100 A4 FAZ 10/150 A4 FAZ 12/10 A4 FAZ 12/20 A4 FAZ 12/30 A4 FAZ 12/50 A4 FAZ 12/100 A4 FAZ 16/25 A4 FAZ 16/50 A4 FAZ 16/100 A4 FAZ 20/30 A4 FAZ 24/30 A4 FAZ 8/10 GS FAZ 8/30 GS A4 FAZ 10/10 GS A4 FAZ 10/30 GS A4 FAZ 12/10 GS A4 FAZ 12/30 GS A4 FAZ 8/10 C FAZ 8/30 C FAZ 8/50 C FAZ 10/10 C FAZ 10/30 C FAZ 12/10 C FAZ 12/30 C FAZ 16/25 C FAZ 16/50 C FAZ 8/10 GS C FAZ 10/10 GS C FAZ 12/10 GS C 1) GS = large washer 1) 1) 1) 1) 1) 1) 68550 68552 68553 68555 93030 68556 68557 96796 68558 78245 68560 93031 68561 68562 68564 68565 68567 68568 90678 90679 79854 93034 70450 93035 70456 93036 90198 90200 91069 90201 90203 90204 90206 90207 90208 90199 90202 90205 1) 1) 1) 1 5 2 6 4 3 0 6 7 3 0 1 7 4 8 5 9 6 1 8 6 2 9 9 1 6 4 4 6 1 5 2 6 3 0 1 8 9 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 8 8 8 10 10 10 10 10 10 10 12 12 12 12 12 16 16 16 24 24 8 8 10 10 12 12 8 8 8 10 10 12 12 16 16 8 10 12 75 95 115 90 100 110 130 150 180 220 115 115 125 145 195 140 165 215 160 185 75 95 90 110 105 125 75 95 115 90 110 105 125 140 165 75 90 105 45 45 45 60 60 60 60 60 60 60 70 70 70 70 70 85 85 85 100 125 45 45 60 60 70 70 45 45 45 60 60 70 70 85 85 45 60 70 74 94 114 93 103 113 133 153 183 233 108 118 128 148 198 146 171 221 172 204 74 94 93 113 108 128 74 94 115 93 113 108 128 146 171 74 93 108 10 30 50 10 20 30 50 70 100 150 10 20 30 50 100 25 50 100 30 30 10 30 10 30 10 30 10 30 50 10 30 10 30 25 50 10 10 10 M8 M8 M8 M 10 M 10 M 10 M 10 M 10 M 10 M 10 M 12 M 12 M 12 M 12 M 12 M 16 M 16 M 16 M 20 M 24 M8 M8 M 10 M 10 M 12 M 12 M8 M8 M8 M 10 M 10 M 12 M 12 M 16 M 16 M8 M 10 M 12 13 13 13 17 17 17 17 17 17 17 19 19 19 19 19 24 24 24 30 36 13 13 17 17 19 19 13 13 13 17 17 19 19 24 24 13 17 19 16 x 1. per box ■ ETA do [mm] l [mm] M SW pcs. drill-hole depth for through fixings td [mm] effect. zinc-plated steel Type Art.5 24 x 2. usable length thread Anchor bolt FAZ C.5 30 x 3 30 x 3 22 x 3 25 x 3 30 x 3 50 50 50 50 25 25 20 20 20 20 20 20 20 20 20 10 10 10 5 5 50 50 50 25 20 20 50 50 50 50 25 20 20 10 10 50 50 20 .88 Anchor bolt FAZ High performance steel anchors Technical DATA Anchor bolt FAZ.6 20 x 2 20 x 2 20 x 2 20 x 2 20 x 2 20 x 2 20 x 2 24 x 2.5 24 x 2.5 24 x 2. 2 133.7 148.8 5.3 5.8 24.7 (22.3* — 33.8) 2) 23.9 A4 13.0 18.4 10.9 16.7) 2) 44.3 47.6 92.9 6.0 — 250 120 200 125 250 150 270 250 125 — — — — — — — — — 270 13.0 40.1 (10.0 56.9 14.6 35.8 20.3 67. edge distance the above described loads have to be reduced! (See “Technical Handbook” or design software “CC-Compufix”) 2) In general the relevant kind of failure has to be defined by the designing engineer.0) 2) 6.0 — 41.8 18.0 14.8 25.0 12.8 6. axial spacing 1) smin [mm] A4 / C — for c ≧ [mm] A4 / C — cmin [mm] gvz 40 for s ≧ [mm] gvz 100 1) Min.8 — 41.6 27.89 LOADS Mean ultimate loads.7 19.1 109.0 23.8) 2) 23.7 18.3 (23.5 33.0 37.0 170 60 95 75 120 65 150 85 165 140 80 130 — — 65 180 — — 110 55.2 17.8 140 50 70 65 100 55 110 65 150 120 50 90 — — 60 120 — — 60 52.1 C 12.0 36.3 4.7 24.8 43.9 14. edge distance cmin [mm] A4 / C — A4 / C — for s ≧ [mm] Required torque T inst [Nm] 20 Mrec [Nm] * steel failure decisive 1) For min.0 — 41.3 — 288.2* 65.4 13.8 20.4 100 35 50 40 50 40 70 45 60 80 35 70 — — 40 100 — — 20 22.3 6.3 26.8* 15.8 120 40 55 55 70 45 80 55 90 100 40 100 — — 60 90 — — 45 27.0 36.4 78.7 6.7 13.1 4.1 21.8 8.4 25.8 — 41.2) 2) 44.5 9.4) 2) 16.3 — 29.0 170 60 95 75 100 65 150 65 175 140 80 130 — — 65 180 — — 110 42.6 20.7 — 222. minimum axial spacings and edge distances Standard structural component hmin.8 16.0 — 200 95 160 100 200 100 220 200 100 — — — — — — — — — 200 47.5 10.2 4.0 (23. High performance steel anchors .3 (14.7 18.7 19.7 13.3* — 43.5 (16.5 31.4 10.9 48.6 8.6) 2) 31.8 (52.8 18.3 52. Design resistant loads: material safety factor γM is included.0 — 91.4 13.5 (22.5 10.3 78.6 8.2* 24.8 (16.5 54.0 14.4* 9.5 31.1 6.9 14.1 26.3 232.6* — 28.3 66.0) 2) 11.3 — 57.4* 29.3 — 64.0) 2) 6.3* 12.7 34.2* 24. Material safety factor γM depends on type of anchor.6* — 22.1 — 29.8 43.0) 2) 9.5 54.5* 35.8 14.0 10.2 26.0 36.7 18. axial spacing and min.2 8.0* 20.6 61.4* 6.9 14.5 24.0 78.1 109.7 43.4 25.7 24.4 13.4 92.9 — 288.7 34.4) 2) 16.0 33.0 6. design resistant and recommended loads for single anchors of fischer Anchor bolt FAZ with large axial spacing and edge distance Anchor size Effective anchorage depth Drill hole depth Drill hole diameter Mean ultimate loads Nu and Vu [kN] Tensile 0° Nu [kN] gvz A4 C gvz A4 C gvz A4 C gvz Shear 90° VRd [kN] A4 C gvz A4 C gvz Shear 90° Vrec [kN] A4 C 15.1 65.8 — 31.3 47.0) 2) 11.3 — 57.7 26.3 35.4 are included.9 6.7 14. axial spacing A4 / C 50 smin [mm] A4 / C 50 for c ≧ [mm] cmin [mm] gvz 40 for s ≧ [mm] gvz 100 1) Min.1 [mm] 100 thickness ( ≧ 2 x hef ) gvz 40 smin [mm] gvz 50 for c ≧ [mm] 1) Min.0 (40.7 (57.1 — 24.2* 65.3 9.5 33.9 14.9* 26.4 13.2 14.9* 18.0 111.0 36.0) 2) 9.1 26. edge distance cmin [mm] A4 / C 50 for s ≧ [mm] A4 / C 50 Reduced structural component hmin.6 360.6 46.0 20. ≧ 20 mm (sizes M10 and M12) and respectively ≧ 25 mm (size M16) as well as a nominal useful length (tfix.4 (37.3 52.0 19.9 13.2 93.0 9.4* 7.4) 2) 16.9) 2) 31.2 133.8 24.6 48.5 33.3 13.0 40.3 9.7 — 64.6 46.4* 17.3 9.3 8.3 232. For further detailed information about European Technical Approvals please contact the responsible fischer representation in your country.3 — 222.8 7.0 — 16. Recommended loads: material safety factor γM and safety factor for load γL = 1.8 43.3 43. The conditions of application may differ from those given in the European Technical Approval.7 26.8 10.1 12.4* 11.7 (32.0 47.0 5.3 6.4 Component dimensions.4 26.0 111.1 (32.8 19.0 37. All load values apply for concrete C20/25 without edge or spacing influences.2 [mm] 80 thickness ( < 2 x hef ) smin [mm] gvz 35 for c ≧ [mm] gvz 70 Min.0 — 250 120 165 125 250 120 220 250 125 — — — — — — — — — 270 M8 45 55 8 M 10 60 75 10 Non-cracked concrete M 12 M 16 70 85 90 110 12 16 M 20 100 130 20 M 24 125 155 24 M8 45 55 8 M 10 60 75 10 Cracked concrete M 12 M 16 70 85 90 110 12 16 M 20 100 130 20 M 24 125 155 24 hef h1 ≧ d0 [mm] [mm] [mm] Shear 90° Vu [kN] Design resistant loads NRd and VRd [kN] Tensile 0° NRd [kN] Recommended loads Nrec and Vrec [kN] Tensile 0° Nrec [kN] Recommended bending moment Mrec [Nm] gvz 14.7 26.5* 35.nom) of the used anchor type not exceeding 50 mm the values in brackets can be used.4 10.6 20.4* 13.7 148.8 120 40 60 55 70 45 80 55 120 100 40 100 — — 60 90 — — 45 38.1 — 20.8 (14. Simplifying for a thickness of the fixture ≧ 15 mm (size M8).4 48.3 13.7 5.6 360.8* 15.8 140 45 70 65 75 55 110 65 100 120 50 90 — — 60 120 — — 60 37.0 — 200 95 200 100 200 130 245 200 100 — — — — — — — — — 200 79.0 29.0 (10.3 8.3 — 91.4) 2) 16. 90 Anchor bolt setting tool FABS High performance steel anchors OVERVIEW Anchor bolt setting tool FABS Suitable for: ▪ The installation of all fischer and Upat anchor bolts (FAZ. ▪ The tool is simply fitted into a standard SDS Plus hammer drill and is perfect for hammering the anchor into the hole. diameter M 6 to M 12. saves time and energy. railings) because the recess at its tip prevents it from slipping and causing damage to the surface. FBN and EXA). per box pcs. Areas of application ▪ Ceiling suspension ▪ Installation in series ▪ Painted railings ▪ Attachment points where access is difficult Description ▪ Especially suitable for the efficient installation in series of larger numbers of fischer and Upat anchor bolts. ▪ Universally usable for M 6 to M 12. fischer Anchor bolt setting tool FABS Type Art.g. This greatly simplifies the installation process when working overhead. EXA 1 . (e.-No. ▪ FABS can also be used for fixing previously painted objects. FBN. ▪ Ergonomic design. ID fits anchor qty. Advantages ▪ Efficient installation of all fischer and Upat anchor bolts. FABS 77937 8 FAZ. per box pcs.230 Torque Wrench Socket FDDP ▪ Required for safe installation of all our hex headed fixings.54 Torque Wrench FTW 50 . No.230 Deep Drive Socket FDDP 10 FDDP 13 FDDP 17 FDDP 19 503324 503325 503326 503327 503328 503329 1 1 1 1 1 1 1 1 1 1 1 1 10 A/F 13 A/F 17 A/F 19 A/F 8-54 50-230 - hex. head fixings hex.91 Torque Wrenches FTW OVERVIEW Torque Wrench FTW 8 . High performance steel anchors Description FTW Torque Wrenches & FDDP Deep Drive Sockets ! New Torque wrench ½“ drive.54 FTW 50 . outer carton pcs. socket ½“ Type Art. qty. head fixings M6 M8 M10 M12 For further detailed information on this product range please contact our technical team of advisors on 01491 827920 . width across nut [mm] torque [Nm] suitable for FTW 8 . ▪ Positive fit in the undercut gives additional safety. ▪ Simple visual control reduces installation effort: no test loading necessary to check whether properly set. eliminating setting errors.4529 Before expansion After the correct expansion 4 imprints for visual check The anchor ist set correctly if the anchor sleeve is flush with the surface of the concrete and the 4 imprints are visual. high corrosion-resistant steel 1. ▪ A4 stainless steel version for outdoor use and in damp conditions. ▪ Internal thread for high flexibility using threaded rods or screws of different lengths and types. C20/25 to C50/60 Also suitable for: ▪ Concrete B15 resp. C12/15 ▪ Natural stone with dense structure ▪ Solid brick ▪ Solid sand-lime brick For fixing of: ▪ Pipes ▪ Ventilation systems ▪ Sprinkler systems ▪ Consoles ▪ Steel constructions ▪ Gratings ▪ Cable trays ▪ Gates ▪ Facades ▪ Suspended ceilings Zykon hammerset anchor FZEA II. ▪ Virtually expansion-free operation allows cost-efficient fixing with small edge distances and axial spacings. saving installation time. ▪ When the internal expansion pin is driven in with the setting tool. Advantages/benefits INSTALLATION Type of installation ▪ Pre-positioned installation STANDARDS You will find everything that has standards on page 313 under the keyword approvals. . resp. ▪ Single-step drilling process simultaneously produces the undercut. Description ▪ Undercut anchor with internal thread for prepositioned installation.92 Zykon hammerset anchor FZEA II The low-cost undercut anchor bolt with internal thread for the cracked tension zone High performance steel anchors OVERVIEW Zykon hammerset anchor FZEA II. ▪ A cylindrical hole with an undercut is produced with the Drill bit FZUB in one work process. zinc-plated steel Approved for: ▪ Cracked and non-cracked concrete B25 to B55 resp. 1.4529) for applications in aggressive atmospheres. stainless steel A4. the anchor sleeve expands and fills the undercut hole with a positive fit. Highly corrosion-resistant steel C (material no. For drilling obligatory 2) 3) 4) 5) 6) For installation of FZEA II the setting mandrel FZED or alternatively the setting tool FZEM is obigatory. bolt penetration e2 [mm] max. zinc-plated steel Type Art.6 5. FZEA II 10 x 40 M 8 FZEA II 12 x 40 M10 FZEA II 14 x 40 M12 FZEA II 10 x 40 M 8 A4 FZEA II 12 x 40 M10 A4 FZEA II 14 x 40 M12 A4 FZEA II 10 x 40 M 8 C FZEA II 12 x 40 M10 C FZEA II 14 x 40 M12 C 47303 47304 47305 47306 47307 47308 47309 47310 47311 0 7 4 1 8 5 2 8 5 ▯ ▯ ▯ ▯ ▯ ▯ ▯ ▯ ▯ 10 12 14 10 12 14 10 12 14 40 40 40 40 40 40 40 40 40 M8 M 10 M 12 M8 M 10 M 12 M8 M 10 M 12 11 13 15 11 13 15 11 13 15 17 19 21 17 19 21 17 19 21 100 100 50 100 100 50 100 100 50 The correct installation of fischer Zykon hammerset anchors in accordance with the approval is possible only with the following original fischer Zykon tools. Setting tool FZED Plus for installation with a hand hammer 1 1 1 1 1 1 1 1 1 LOADS Mean ultimate loads.7 Recommended shear load Vperm of one single anchor without edge influence. per box pcs.8 5. High performance steel anchors .5 x hef and axial spacing s ≥ 3 x hef Nperm [kN] 4.0 C gvz FZEA II 12 x 40 M10 A4 40 4.93 Technical DATA Zykon hammerset anchor FZEA. threaded rod of the minimum strength class A50.-No.6 8.6 5. annex C) if combined tensile and shear loads.6 8. 1) Recommended tensile load Nperm of one single anchor without edge influence.. i. Anchor type gvz Effective anchorage depth In cracked concrete C20/252) In non-cracked concrete C20/252) In cracked concrete C20/252) In non-cracked concrete C20/252) Anchor characteristics Characteristic axial spacing Characteristic edge distance Minimum axial spacing Minimum edge distance Minimum structural component thickness Minimum screw penetration depth Maximum screw penetration depth Clearance-hole in fixture to be attached Installation torque Universal drill bit FZUB5) Setting mandrel FZED6) Machine setting tool FZEM6) Scr.7 5.4 are considered. threaded rod of the minimum strength class 5.7 5. edge distance c ≥ 1. fits internal thread fischer Zykon anchor name qty. i.5 x hef) 45 45 80 13 19 12 < 20 FZUB 12 x 40 FZED 12 x 40 FZEM 12 x 40 < 20 < 20 50 50 80 15 21 14 < 40 FZUB 14 x 40 FZED 14 x 40 FZEM 14 x 40 < 40 hef Nperm [mm] [kN] FZEA II 10 x 40 M8 A4 40 4. FZUB 10 x 40 FZUB 12 x 40 FZUB 14 x 40 FZEM 10 x 40 FZEM 12 x 40 FZEM 14 x 40 FZED 10 Plus FZED 12 Plus FZED 14 Plus 60622 60623 60624 60648 60649 60650 44642 44643 44644 FZEA II 10 x 40 FZEA II 12 x 40 FZEA II 14 x 40 FZEA II 10 x 40 FZEA II 12 x 40 FZEA II 14 x 40 FZEA II 10 x 40 FZEA II 12 x 40 FZEA II 14 x 40 M8 M 10 M 12 M8 M 10 M 12 M8 M 10 M 12 Drill bit FZUB Machine setting tool FZEM for installation with a hammer drill.N Ccr. For higher concrete strength classes an increase in performance of up to 55% is possible. For the design the complete approval ETA-06/0271 is to be observed. edge distance c ≥ 10 x hef and axial spacing s ≥ 3 x hef Vperm Vperm [kN] [kN] 4. Please observe the design method A (ETAG. FIRE PROTECTION CORROSION Red hot: see page 308 for information about fire protection. edge influences and influences of spacings of anchor groups are to consider. bolt penetration e1 [mm] qty. Drilling and setting tools Type Art.8 5.6 The partial safety factors for resitance and the partial safety factor for load with Y F = 1. All about corrosion and how you can avoid it is written on page 309.7 4. Values in brackets apply to the use of a fixing screw resp.-No. stainless steel A4 min.6. design resistant and recommended loads for single anchors of fischer Zykon hammerset anchor FZEA II Recommended loads1) of single anchors in normal-weight concrete C20/252).7 5. The concrete is considered to be normally reinforced or non-reinforced.N Smin cmin hmin min ℓs max ℓs df Tinst [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [Nm] [---] [---] [---] < 10 40 40 80 11 17 9 < 15 FZUB 10 x 40 FZED 10 x 40 FZEM 10 x 40 < 15 < 15 120 (= 3 x hef) 60 (= 1.3 C gvz FZEA II 14 x 40 M12 A4 40 4.e.7 C Note: With the Design software COMPUFIX you can use the full performance of the fischer Zykon hammerset anchor FZEA II and you are able to do designs with individual surrounding conditions.7 7. per box pcs. Values in brackets apply to the use of a fixing screw resp.e. ID approval ▯ DIBt drill-Ø do [mm] anchorage depth hef [mm] internal thread ds Zykon hammerset anchor FZEA. .5 160 80 150 FA10 15.0 400 150 200 Axial spacing Edgae distance Min. ID drill Ø do [mm] min. m Frec B25 B25 [mm] [mm] [mm] FA8 12. fxing thickness da [mm] torque width across nut SW qty.5 240 100 150 FA12 20.5 260 130 200 FA14 25.94 Through bolt FA High performance steel anchors The economical. component thickness FIXING PRINCIPLES In detail: The general principles for installation.4 6. the tapered cone is pulled into the expansion sleeve and expands it against the hole wall guaranteeing an even calibrated hold in all compact materials.8 2. ▪ Demountable for leaving a flush surface INSTALLATION Type of installation ▪ Push-through installation Technical DATA fischer through bolt FA Type Art. m [kN] (mean values) and recommended loads Frec [kN] for single anchors of through bolt FA in non-cracked concrete. FA 8/15 (8x70) FA 8/25 (8 x 85) FA 10/15 (10 x 85) FA 10/50 (10 x 120) FA 12/15 (12 x 100) FA 12/50 (12 x 135) FA 14/20 (14 x 115) 500511 500512 500515 500516 500522 500523 500526 8 8 10 10 12 12 14 75 90 90 120 100 135 115 50 50 60 60 70 70 80 65 80 75 110 85 120 100 15 25 15 50 15 50 20 10 10 20 20 35 35 50 13 13 17 17 19 19 22 25 25 25 25 20 20 10 Ultimate loads Fu. anchorage depth hv [mm] anchor length l [mm] max. ideal for stadium seating OVERVIEW Through bolt FA Suitable for: ▪ Concrete ≥ B15 ▪ Dense natural stone For fixing of: ▪ Ballastrading ▪ Stadium seating ▪ Railings ▪ Handrails ▪ Stock pens ▪ Supports ▪ Machines ▪ Consoles ▪ Metal constructions ▪ Metal profiles demountable Description ▪ Anchor bolt for push-through installation. ▪ When the hexagonal bolt is tightened. demountable through bolt.3 4.4 3. per box Md pcs. Anchor type/thread Fu. the correct drilling procedure and much more on page 303.-No. ▪ The red knurled collar prevents the anchor turning in the hole on installation. drill-hole depth for through fixings td [mm] min. ▪ FH II-SK is not available in stainless steel Advantages/benefits ▪ The half-moon-shaped recesses stamped in the sleeve allows for contraction in length when tightened.95 High performance anchor FH II The heavy-duty sleeve anchor for structurally demanding fixing. High performance steel anchors . FH II-H (cap nut) and FH II-SK (countersunk screw) ▪ All anchors can be removed flush with the surface. INSTALLATION Type of installation ▪ Push-through installation STANDARDS You will find everything that has standards on page 313 under the keyword approvals. the cone is pulled into the expansion sleeve and expands tensioning it against the hole wall. ▪ When the hexagon nut or screw is tightened. OVERVIEW High performance anchor FH II-H Approved for: ▪ Cracked and non-cracked concrete C20/25 to C50/60 Also suitable for: ▪ Concrete C12/15 ▪ Natural stone with dense structure For fixing of: ▪ Steel constructions ▪ Railings ▪ Consoles ▪ Ladders ▪ Cable trays ▪ Machines ▪ Staircases ▪ Gates ▪ Facades ▪ Window elements High performance anchor FH II-B M8 to M16 High performance anchor FH II-S High performance anchor FH II-SK High performance anchor FH A4 Description ▪ Heavy-duty sleeve anchor for push-through installation. This clamps the item being attached firmly against the concrete surface. ▪ Anchor versions for fixings with sophisticated design: FH II-S (hexagon head screw). ▪ A4 stainless steel version for outdoor use and in damp conditions (not part of the approval). -No. usable length t fix [mm] thread width across nut qty. ID approval drill-Ø min. drill-hole effect. drill-hole effect. usable length t fix [mm] thread width across nut qty. per box td h ef t fix ■ ETA do [mm] l [mm] M SW pcs. anchorage depth for through depth fixings td [mm] hef [mm] total length max.-No. ID approval drill-Ø min.96 High performance steel anchors Technical DATA High performance anchor FH II-H. FH 10/10 H FH 10/25 H FH 10/50 H FH II 12/10 H FH II 12/25 H FH II 12/50 H FH II 15/10 H FH II 15/25 H FH II 15/50 H FH II 18/25 H FH II 18/50 H 45055 45056 45057 44905 44906 44907 44908 44909 44910 44915 44916 0 7 4 9 6 3 0 7 3 8 5 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 10 10 10 12 12 12 15 15 15 18 18 85 100 125 90 105 130 100 115 140 130 155 50 50 50 60 60 60 70 70 70 80 80 90 105 130 93 108 133 113 128 153 139 164 10 25 50 10 25 50 10 25 50 25 50 M6 M6 M6 M8 M8 M8 M 10 M 10 M 10 M 12 M 12 13 13 13 17 17 17 17 17 17 19 19 50 50 50 50 50 25 25 25 25 20 20 d0 T inst High performance anchor FH II-B. zinc-plated steel Type Art. M d0 T inst FH 10/10 B FH 10/25 B FH 10/50 B FH II 12/10 B FH II 12/25 B FH II 12/50 B FH II 12/100 B FH II 15/10 B FH II 15/25 B FH II 15/50 B FH II 15/100 B FH II 18/25 B FH II 18/50 B FH II 18/100 B FH II 24/25 B FH II 24/50 B FH II 24/100 B FH II 28/30 B FH II 28/60 B FH II 32/30 B FH II 32/60 B *) Approval applied 45001 45002 45003 48773 48774 48775 46832 48776 48777 48778 46835 48779 48780 46841 48886 48887 46842 47547 47548 47549 47550 7 4 1 0 7 4 6 1 8 5 7 2 8 8 7 4 5 8 5 2 8 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ *) *) *) *) 10 10 10 12 12 12 12 15 15 15 15 18 18 18 24 24 24 28 28 32 32 80 95 120 90 105 130 190 100 115 140 190 130 155 205 150 175 225 185 215 210 240 50 50 50 60 60 60 60 70 70 70 70 80 80 80 100 100 100 125 125 150 150 85 100 125 90 105 130 184 110 125 150 200 135 160 214 167 192 242 198 228 228 258 10 25 50 10 25 50 100 10 25 50 100 25 50 100 25 50 100 30 60 30 60 M6 M6 M6 M8 M8 M8 M8 M 10 M 10 M 10 M 10 M 12 M 12 M 12 M 16 M 16 M 16 M 20 M 20 M 24 M 24 10 10 10 13 13 13 13 17 17 17 17 19 19 19 24 24 24 30 30 36 36 50 50 50 50 50 25 25 25 25 25 20 20 20 10 10 10 5 4 4 4 4 . anchorage depth for through depth fixings td [mm] hef [mm] total length max. zinc-plated steel Type Art. per box td h ef t fix ■ ETA do [mm] l [mm] M SW pcs. 8 22 25 90° 90° FIRE PROTECTION CORROSION Red hot: see page 308 for information about fire protection. SK 5. ID approval drill-Ø min. SK FH II 15/. ID approval drill-Ø min. anchorage depth for through depth fixings td [mm] hef [mm] total length max. usable length t fix [mm] thread width across nut qty. per box td h ef t fix ■ ETA do [mm] l [mm] M SW pcs. drill-hole effect.97 High performance anchor FH II Technical DATA High performance anchor FH II-S.-No. per box td h ef t fix x ■ ETA do [mm] l [mm] M SW pcs. anchorage depth for through depth fixings td [mm] hef [mm] total length max.8 5.. FH 10/10 S FH 10/25 S FH 10/50 S FH II 12/10 S FH II 12/25 S FH II 12/50 S FH II 15/10 S FH II 15/25 S FH II 15/50 S FH II 18/10 S FH II 18/25 S FH II 18/50 S FH II 24/25 S FH II 24/50 S FH II 28/30 S FH II 28/60 S FH II 32/30 S FH II 32/60 S FH 10/10 S A4 FH 12/10 S A4 FH 12/25 S A4 FH 15/10 S A4 FH 15/25 S A4 FH 15/50 S A4 FH 18 x 100/25 S A4 FH 18 x 100/50 S A4 45030 45031 45032 44884 44885 44886 44887 44888 44889 46847 44894 44896 44898 44900 44901 44902 44903 44904 45222 45224 45102 45226 45104 45105 45106 45107 7 4 1 7 4 1 8 5 2 0 6 0 4 4 1 8 5 2 6 0 1 4 5 2 9 6 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 10 10 10 12 12 12 15 15 15 18 18 18 24 24 28 28 32 32 10 12 12 15 15 15 18 18 85 100 125 90 105 130 100 115 140 115 130 155 150 175 185 215 210 240 85 95 110 110 125 150 160 185 50 50 50 60 60 60 70 70 70 80 80 80 100 100 125 125 150 150 50 60 60 70 70 70 100 100 84 99 124 90 105 130 107 122 147 118 133 158 160 185 193 223 215 245 84 95 110 111 126 151 158 183 10 25 50 10 25 50 10 25 50 10 25 50 25 50 30 60 30 60 10 10 25 10 25 50 25 50 M6 M6 M6 M8 M8 M8 M 10 M 10 M 10 M 12 M 12 M 12 M 16 M 16 M 20 M 20 M 24 M 24 M6 M8 M8 M 10 M 10 M 10 M 12 M 12 10 10 10 13 13 13 17 17 17 19 19 19 24 24 30 30 36 36 10 13 13 17 17 17 19 19 50 50 50 50 50 25 25 25 25 20 20 20 10 10 4 4 4 4 50 50 20 50 20 10 10 10 d0 T inst High performance anchor FH II-SK. High performance steel anchors . zinc-plated steel Type Art. usable length t fix [mm] thread width across nut qty. zinc-plated steel Type Art.. All about corrosion and how you can avoid it is written on page 309..-No. drill-hole effect.. FH II 12/15 SK FH II 12/25 SK FH II 12/50 SK FH II 15/15 SK FH II 15/25 SK FH II 15/50 SK FH II 18/15 SK FH II 18/25 SK FH II 18/50 SK 44917 44918 44919 44920 44921 44922 44923 44924 44925 2 9 6 2 9 6 3 0 7 ■ ■ ■ ■ ■ ■ ■ ■ ■ 12 12 12 15 15 15 18 18 18 95 105 130 105 115 140 120 130 155 60 60 60 70 70 70 80 80 80 90 100 125 100 110 135 115 125 150 15 25 50 15 25 50 15 25 50 M8 M8 M8 M 10 M 10 M 10 M 12 M 12 M 12 5 5 5 6 6 6 8 8 8 25 25 25 25 25 25 20 20 20 d0 90 ° D T inst X [mm] ∅D [mm] counter bore FH II 12/.. 98 High performance steel anchors LOADS Mean ultimate loads, design resistant and recommended loads for single anchors of fischer High-performance anchor FH II and FH 10 with large axial spacing and edge distance Non-cracked concrete Anchor size FH 10 M6 gvz Effective anchorage depth Drill hole depth Drill hole diameter Mean ultimate loads Nu and Vu [kN] Tensile Shear 0˚ 90˚ Nu Vu [kN] [kN] gvz A4 gvz A4 Design resistant loads NRd and VRd [kN] Tensile Shear 0˚ 90˚ NRd VRd [kN] [kN] gvz A4 gvz A4 Recommended loads Nrec and Vrec [kN] Tensile Shear 0˚ 90˚ Nrec Vrec [kN] [kN] gvz A4 gvz A4 Recommended bending moment Mrec [Nm] Mrec Anchor characteristics Characteristic axial spacing Characteristic edge distance Minimum axial spacing1) Minimum edge distance1) Minimum structural component thickness Clearance-hole in fixture to be attached Required torque Scr,N Ccr,N Smin for c ≥ cmin for s ≥ hmin df Tinst [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [Nm] 50 100 50 100 100 12 10 60 100 60 100 120 14 22.5 (17.5)3) 70 100 70 140 140 17 40 (38)3) = 3 x hef = 1.5 x hef 80 160 80 200 160 20 80 100 200 100 220 200 26 160 (75)3) 375 375 250 31 180 450 450 300 35 200 50 100 50 100 100 12 10 50 80 50 80 120 14 60 120 60 120 140 17 = 3 x hef = 1.5 hef 70 140 70 160 160 20 80 80 180 80 200 200 26 160 (75)3) 375 375 250 31 180 450 450 300 35 200 [Nm] gvz A4 6.9 4.9 17.1 12.0 34.3 24.0 60.0 — 152.0 42.0 296.0 — 512.0 208.1 6.9 359.6 17.1 4.9 34.3 12.0 60.0 24.0 152.0 — 296.0 42.0 512.0 — 6.8 5.4 7.7 5.4 11.2 8.3 14.3 (17.1)2) 7.9 14.1 12.8 22.9 (26.9)2) 13.0 18.9 — 33.7 (37.8)2) — 26.4 18.1 52.8 19.2 36.9 — 73.8 — 48.5 30.7 97.0 39.3 3.8 38.0 6.1 52.1 7.0 — 14.3 (15.9)2) — 10.0 — 20.1 — 12.2 — 24.5 — 17.1 — 34.3 — 24.0 — 47.9 — 31.5 — 63.0 — 9.5 7.5 10.8 7.5 15.6 11.6 20.0 (24.0)2) 11.1 19.7 18.0 32.0 (37.6)2) 18.2 26.4 — 47.2 (52.9)2) — 37.0 25.4 73.9 26.8 51.7 — 103.3 — 67.9 43.0 135.8 55.0 5.3 53.2 8.5 72.9 9.8 — 20.0 (22.3)2) — 14.1 — 28.1 — 17.1 — 34.3 — 24.0 — 48.0 — 33.5 — 67.1 — 44.1 — 88.2 — 16.0 14.1* 13.5* 19.8* 29.3* 22.3 30.6* (36.1*)2) 29.5* 39.5 34.3 48.7* (56.9*)2) 48.3* 48.3 — 71.1* (82.5*)2) — 67.5 55.8 148.6* 71.6* 94.3 — 170.4* — 124.0 94.3 223.1* 102.9* 14.1 134.6 13.5* 148.3* 21.0 14.1* 30.6* (36.1*)2) 19.8* 27.7 19.5 48.7* (56.9*)2) 29.5* 33.8 28.3 71.1* (82.5*)2) 48.3* 47.3 — 148.6* — 66.0 45.5 170.4* 71.6* 86.8 — 223.1* — hef h1 ≥ d0 [mm] [mm] [mm] 50 75 (70)3) 10 FH II 12 M8 gvz 60 80 12 FH II 15 M10 gvz 70 90 15 FH II 18 M12 gvz 80 105 18 FH II 24 M16 gvz 100 125 24 FH II 28 M20 gvz 125 155 28 FH II 32 M24 gvz 150 180 32 FH 10 M6 gvz 50 75 (70)1) 10 FH II 12 M8 gvz 60 80 12 M10 gvz 70 90 15 Cracked concrete FH II 15 FH II 18 M12 gvz 80 105 18 FH II 24 M16 gvz 100 125 24 FH II 28 M20 gvz 125 155 28 FH II 32 M24 gvz 150 180 32 22.5 (17.5)3) 40 (38)3) All values apply for concrete C20/25 without edge or spacing influences. Design resistant loads: material safety factor γM is included. Material safety factor γM depends on the type of anchor. Recommended loads: material safety factor γM and safety factor for load γL =1.4 are included. *Steel failure decisive For minimum axial spacing and minimum edge distance the above described loads have to be reduced (See ‚fischer Technical Handbook‘ or design software ‚CC-COMPUFIX‘)! 2) Values in brackets are valid for screw type FH II-S and type with countersunk screw head FH II-SK only. 3) Values in brackets are valid bolt type FH II-B resp. FH 10 B only. 1) The conditions of application may differ from those given in the European Technical Approval. For further detailed information about ETA‘s please contact your local fischer representative. CORROSION All about corrosion and how you can avoid it is written on page 309. 99 Multi Bolt FMB OVERVIEW Multi Bolt FMB pre-assembled, zinc-plated steel Multi Bolt FMB components Suitable for: ▪ Concrete ≧ C12/15 ▪ Natural stone with dense structure For fixing of: ▪ Bracings of formwork ▪ Precast concrete tilt up panels High performance steel anchors Easy to install - Easy to remove - Safe to reuse. Description ▪ Anchor bolt consisting of expansion component and anchor screw ▪ For the temporary fixing of bracings and concrete tilt up panels. ▪ Expansion component with fischer expertise for maximum anchorage. ▪ No projecting parts after removal of the anchor screw. This offers a time saving method which provides a high level of safety on site. ▪ The hexagon nut can also be used for other applications, a change of setting tool is not required. ▪ Large washer for better load distribution. Advantages/benefits ▪ Economical system, as the anchor screw can be re-used up to five times. ▪ 20 mm steel diameter of the anchor screw for higher shear forces. INSTALLATION Type of installation Installation tips Assembly ▪ Push-through installation ▪ Before setting, the expansion component needs to be screwed into the anchor screw until it‘s firm. ▪ Only use the anchor screw up to five times to ensure the safety of the fixing. ▪ The usage can be indicated on the packaging. ▪ After working unscrew the hexagonal bolt. ▪ The expansion element remains in the drill-hole. ▪ Return the screw and the washer into the box. Installation Removal Reusability Technical DATA Multi Bolt FMB, zinc-plated steel Type Art.-No. ID drill-Ø d0 [mm] drill hole depth h0 [mm] Multi Bolt FMB, 20 EXP anchor length max. usable length l [mm] t fix [mm] thread M width across nut SW [mm] pcs. washer qty. per box FMB 20/20 Set FMB 20 EXP 96840 96841 6 20 100 138 20 M 16 30 44 x 3 1) 1) 2 hexagon head screws with washer, 10 expansion components Loads Loads of a single fixing FMB 20 with large axial spacing and edge distances Max. recommended tensile load Nrec of a single fixing with large axial spacings and edge distances (c ≥ hef and s ≥ scr) Uncracked concrete fck = 20 N/mm2 Max. shear force-bearing capacity Vrec of a single fixing with large axial spacing and edge distances (c ≥ hef and s ≥ scr) Steel, strength class: 8.8 Installation torque Tinst [kN] [Nm] 64 150 [kN] 20 FIXING PRINCIPLES STANDARDS In detail: The general principles for installation, the correct drilling procedure and much more on page 303. You will find everything that has standards on page 313 under the keyword approvals. 100 Heavy-duty anchor TA M High performance steel anchors The flexible, low-cost sleeve anchor for the non-cracked compression zone. OVERVIEW Heavy-duty anchor TA M Approved for: ▪ Non-cracked concrete C12/15 to C50/60 Also suitable for: ▪ Concrete C12/15 ▪ Natural stone with dense structure For fixing of: ▪ Steel constructions ▪ Handrails ▪ Consoles ▪ Ladders ▪ Cable trays ▪ Machines ▪ Staircases ▪ Gates ▪ Facades ▪ Window elements ▪ Stand-off installations ▪ Park benches ▪ Trash cans ▪ Gratings Heavy-duty anchor TA M-S with screw, zinc-plated steel Heavy-duty anchor TA M-T, for pushthrough installation Heavy-duty anchor TA M8 BP, with twist-off head TA M8 BP, features security head Description ▪ Heavy-duty sleeve anchor for pre-positioned installation (Internally-threaded anchor TA M, anchor with screw. TA M-S) and push-through installation (TA M-T and TA M8 BP). ▪ When the bolt or hexagon nut is tightened, the cone is pulled into the expansion sleeve and expands it against the hole wall. ▪ Special tamper-proof fixing as protection against theft (TA M8 BP). Advantages/benefits ▪ Suitable for all bolts or studs with metric thread. ▪ Fixing can be easily driven in, therefore less installation effort. ▪ Surface-flush fixing allows the mounted item to be removed and refitted several times. ▪ Plastic cap protects against contamination with drilling dust and ensures the thread remains free-running. ▪ Anchor version with internal thread for high flexibility by using threaded rods or screws of different lengths and type. ▪ Three-part expansion sleeve allows even load distribution and small edge and axial spacing. FIXING PRINCIPLES STANDARDS In detail: The general principles for installation, the correct drilling procedure and much more on page 303. You will find everything that has standards on page 313 under the keyword approvals. TA M-T) Type of installation Pre-positioned installation Installation tips ▪ ▪ For correct installation.-No.-No. zinc-plated steel Type Art. for push-through installation Type Art. or the stud can be locked with a locknut. ID approval ■ ETA drill-Ø do [mm] min.. the fixing sleeve of the TA M and TA M-S has to be supported on the attached item.101 INSTALLATION ▪ Pre-positioned and stand-off installation (TA M. ID approval ■ ETA drill-Ø do [mm] min. drill hole depth t [mm] anchor length l [mm] max. High performance steel anchors . usable length thread width across nut qty. per box TA M6 TA M8 TA M10 TA M12 90245 90246 90247 90248 5 2 9 6 ■ ■ ■ ■ 10 12 15 18 65 70 90 105 49 56 69 86 M6 M8 M 10 M 12 50 50 25 25 Heavy-duty anchor TA M-S with screw. usable length t fix [mm] thread width across nut SW [Ø x length] pcs. zinc-plated steel Type Art. TA M6 T/25 S TA M8 T/25 S TA M10 T/25 S TA M12 T/25 S 90267 90268 90269 90270 7 4 1 7 ■ ■ ■ ■ 10 12 15 18 90 95 110 120 80 85 100 110 25 25 25 25 M6 M8 M 10 M 12 10 13 17 19 50 50 25 20 FIRE PROTECTION Red hot: see page 308 for information about fire protection.-No. TA M-S) ▪ Push-through installation (TA M8 BP. Observe the required screw-in depth in the fixing when determining the bolt length Is: Push-through installation Anchor length + Thickness of the building component tfix + Washer = Screw length Technical DATA Heavy-duty anchor TA M. per box TA M6 S/10 TA M8 S/10 TA M10 S/20 TA M12 S/25 90249 90250 90251 90252 3 9 6 3 ■ ■ ■ ■ 10 12 15 18 75 80 110 130 49 56 69 86 10 10 20 25 M 6 x 60 M 8 x 65 M 10 x 90 12 x 110 10 13 17 19 50 50 25 20 Heavy-duty anchor TA M-T. drill hole depth for pre-fixing t [mm] anchor length l [mm] thread M pcs. qty. drill hole depth for push-through installation td [mm] screw length max. ID approval drill-Ø min. qty. per box ■ ETA do [mm] ls [mm] t fix [mm] M SW pcs. 9* 18. per box do [mm] l [mm] t fix [mm] Tinst SW pcs. axial spacing2) smin [mm] Min. edge distance2) cmin [mm] Min. design resistant and recommended loads for single anchors of fischer Heavy Duty Anchor TA M with large axial spacing and edge distance. minimum axial spacings and edge distances Min.0 23. edge distance the above described loads have to be reduced! (See “Technical Handbook” or design software “CC-Compufix”) All load values apply for concrete C20/25 without edge or spacing influence.4 9.7 90 60 100 20 25. Recommended loads: material safety factor γM and safety factor for load γL = 1.3 14. TA M-S Drill hole depth for TA M-T Drill hole diameter Mean ultimate loads Nu [kN] Tensile Shear Design resistant loads NRd [kN] Tensile Shear TA M61) 40 65 60 10 gvz gvz gvz gvz 11.3 80 50 100 10 Non-cracked concrete TA M81) TA M101) 45 55 70 90 65 80 12 15 16.9 17.4* 13.0 110 70 110 40 TA M121) 70 105 95 18 32. For further detailed information about ETA please contact your local fischer representative.1 32. The conditions of application may differ from those given in the European Technical Approval. Anchor size Effective anchorage depth Drill hole depth for TA M.0 160 120 140 75 hef h1 ≧ h1 ≧ d0 Nu Vu NRd VRd [mm] [mm] [mm] [mm] [kN] [kN] [kN] [kN] Recommended loads Nrec [kN] Tensile Nrec [kN] gvz Shear Vrec [kN] gvz Component dimensions. usable length Installation torque width across nut qty.0 21. with twist-off head Type Art. Material safety factor γM depends on type of anchor.0 6. ID drill min.8 12.102 Heavy-duty anchor TA M High performance steel anchors Technical DATA Heavy-duty anchor TA M8 BP. structural component thickness hmin [mm] Required torque T inst [Nm] * 1) 2) steel failure decisive The values apply to screws with a strength classification 8. . drill hole depth for push-trough installation td [mm] anchor length max.9* 5.5 6.-No.4 are included.8 For min.4 6. Design loads: material safety factor γM is included.6* 9.6 4. axial spacing and min.1 9.5 11.3 15.9 4.2 3. TA M8 BP 90265 3 12 95 85 25 until head twists off 13 50 LOADS Mean ultimate loads. the tapered bolt is pulled into the expansion clip and expands it against the hole wall. Advantages/benefits EXAMPLE . zinc-plated steel Approved for: ▪ Non-cracked concrete C20/25 to C50/60 Also suitable for: ▪ Concrete C12/15 ▪ Natural stone with dense structure For fixing of: ▪ Steel constructions ▪ Railings ▪ Consoles ▪ Ladders ▪ Cable trays ▪ Machines ▪ Staircases ▪ Gates ▪ Facades ▪ Window elements ▪ Wooden constructions Bolt FBN A4.g. for small loads or if reinforcements are hit. OVERVIEW Bolt FBN II. ▪ Embossed letter on the head for subsequent control of the installation as it indicates the setting depth. the hexagon nut must be brought into the optimal installation position (the bolt projecting by 2 to 3 mm). wire gratings.103 Bolt FBN II The flexible. ▪ For wooden structures use the FBN II GS with large washer as per DIN 440. ▪ A4 stainless steel and hot-dip galvanised version for outdoor use and in damp conditions. zinc-plated steel Bolt FBN 8 H Description ▪ Anchor bolt for push-through and pre-positioned installation ▪ When the hexagon nut is tightened. ▪ Long thread allows stand-off installations and variable usable lengths. stainless steel A4 Bolt FBN II-GS (with large washer). e.reduced load INSTALLATION Type of installation FBN ▪ Push-through and pre-positioned installation Installation tips ▪ For series installation we recommend the Anchor bolt setting tool FABS (see page 90) to reduce installation time.maximum load ▪ Maximum usable length of 40 mm at anchorage depth of 65 mm . ▪ Before driving in. etc. low-cost expansion bolt for the non-cracked compression zone. High performance steel anchors . FBN 8 H STANDARDS You will find everything that has standards on page 313 under the keyword approvals. ▪ Hook anchor FBN 8 H for simple installation of meshed reinforcements.FBN II 16/25 ▪ Usable Standard length of 25 mm at anchorage depth of 80 mm . ▪ FBN II 8 K to FBN II 20 K mm diameter also for reduced anchorage depths. Short Version FBN II 8/5 K FBN II 8/10 K FBN II 8/30 K FBN II 10/5 K FBN II 10/10 K FBN II 10/30 K FBN II 12/5 K FBN II 12/10 K FBN II 12/30 K FBN II 16/15 K FBN II 16/25 K FBN II 20/10 K 45130 45136 45137 40662 40664 40669 40700 40771 40777 40783 40827 40851 40854 40855 40931 40943 40944 40945 40950 44558 45263 45264 45265 45266 45267 45268 45269 45564 45565 45566 45567 45568 45569 45570 45573 45574 45575 45576 40806 40807 40826 40946 40947 40948 45272 45273 45274 45571 45572 45577 4 6 3 5 9 4 4 4 6 7 8 3 4 1 2 5 2 9 3 7 9 6 3 0 7 4 1 7 4 1 8 5 2 8 9 6 3 0 3 0 1 6 3 0 1 8 5 5 2 7 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ A B D F K M P B D F K M P S T B D F K N P R S T E K N P S T V F L N R -A-B-F-A-B-F-A-B-F-C-E-B- 6 6 6 8 8 8 8 8 8 8 10 10 10 10 10 10 10 10 12 12 12 12 12 12 12 12 12 16 16 16 16 16 16 16 20 20 20 20 8 8 8 10 10 10 12 12 12 16 16 20 5/ 10/ 30/ 5/15 10/20 20/30 30/40 50/60 70/80 100/110 10/20 20/30 30/40 50/60 70/80 100/110 140/150 160/170 10/25 20/35 30/45 50/65 80/95 100/115 120/135 140/155 160/185 25/40 50/65 80/95 100/115 140/155 160/175 200/215 30/55 60/85 80/105 120/145 . FBN 6/5 FBN 6/10 FBN 6/30 FBN II 8/5 FBN II 8/10 FBN II 8/20 FBN II 8/30 FBN II 8/50 FBN II 8/70 FBN II 8/100 FBN II 10/10 FBN II 10/20 FBN II 10/30 FBN II 10/50 FBN II 10/70 FBN II 10/100 FBN II 10/140 FBN II 10/160 FBN II 12/10 FBN II 12/20 FBN II 12/30 FBN II 12/50 FBN II 12/80 FBN II 12/100 FBN II 12/120 FBN II 12/140 FBN II 12/160 FBN II 16/25 FBN II 16/50 FBN II 16/80 FBN II 16/100 FBN II 16/140 FBN II 16/160 FBN II 16/200 FBN II 20/30 FBN II 20/60 FBN II 20/80 FBN II 20/120 FBN II K ./10 20/ 25/ 25/ 40/30 40/30 40/30 40/30 40/30 40/30 40/30 50/40 50/40 50/40 50/40 50/40 50/40 50/40 50/40 65/50 65/50 65/50 65/50 65/50 65/50 65/50 65/50 65/50 80/65 80/65 80/65 80/65 80/65 80/65 80/65 105/80 105/80 105/80 105/80 ./40 ./30 ./65 ./30 . All about corrosion and how you can avoid it is written on page 309./65 ./10 ./5 ./30 ./50 . per box ■ ETA do [mm] da [mm] [Ø x length] pcs.. anchorage depth hef [mm] min./5 .104 Bolt FBN II High performance steel anchors Technical DATA Bolt FBN II./40 ./5 ./50 ./25 ./50 ./40 ./65 45 50 70 61 66 76 86 106 126 156 78 88 98 118 138 168 208 228 95 105 115 135 165 185 205 225 245 129 154 184 204 244 264 304 165 195 215 255 51 56 76 63 68 88 75 80 100 104 114 120 40 55 75 66 71 81 91 111 131 161 86 96 106 126 146 176 216 236 106 116 126 146 176 196 216 236 256 145 170 200 220 260 280 320 184 214 234 274 56 61 81 71 76 96 86 91 111 120 130 139 M 6 x 16 M 6 x 30 M 6 x 30 M 8 x 34 M 8 x 39 M 8 x 49 M 8 x 59 M 8 x 79 M 8 x 99 M 8 x 100 M 10 x 46 M 10 x 56 M 10 x 66 M 10 x 86 M 10 x 100 M 10 x 100 M 10 x 100 M 10 x 100 M 12 x 59 M 12 x 69 M 12 x 79 M 12 x 99 M 12 x 129 M 12 x 149 M 12 x 169 M 12 x 189 M 12 x 100 M 16 x 89 M 16 x 114 M 16 x144 M 16 x 164 M 16 x 100 M 16 x 100 M 16 x 100 M 20 x 50 M 20 x 90 M 20 x 90 M 20 x90 M 8 x 24 M 8 x 29 M 8 x 49 M 10 x 31 M 10 x 36 M 10 x 56 M 12 x 39 M 12 x 44 M 12 x 64 M 16 x 64 M 16 x 74 M 20 x - 100 100 100 50 50 50 50 50 20 20 50 50 50 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 10 10 10 10 10 10 10 10 10 10 50 50 50 50 50 50 20 20 20 10 10 10 FIRE PROTECTION CORROSION Red hot: see page 308 for information about fire protection. zinc-plated steel Type Art./15 ./30 . ID approval Imprint on head drill-Ø usable length effect./30 ./10 . drill-hole total length depth for through fixings td [mm] l [mm] thread qty./30 . .-No./10 . after) the slash belong together.105 Technical DATA Bolt FBN A4. stainless steel A4 Type Art. per box ■ ETA do [mm] da [mm] FBN 6/10 A4 FBN 6/30 A4 FBN 8/10 + 23 A4 FBN 8/30 + 43 A4 FBN 8/50 + 63 A4 FBN 10/15 + 23 A4 FBN 10/50 + 58 A4 FBN 10/100 + 108 A4 FBN 12/15 + 35 A4 FBN 12/45 + 65 A4 FBN 12/100 + 120 A4 FBN 16/10 A4 FBN 16/25 + 45 A4 FBN 16/50 + 70 A4 FBN II 12/80 GS FBN II 12/100 GS FBN II 12/120 GS FBN II 12/140 GS FBN II 12/160 GS FBN II 12/180 GS FBN II 12/200 GS FBN II 12/250 GS FBN II 16/80 GS FBN II 16/100 GS FBN II 16/120 GS FBN II 16/140 GS FBN II 16/160 GS FBN II 16/180 GS FBN II 16/200 GS FBN II 16/250 GS FBN II 16/300 GS 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 69087 69088 69089 69090 69091 69092 69093 69094 69095 69096 69097 69098 69099 69100 45578 45579 45580 45581 45583 45584 45585 45586 45587 45588 45589 45590 45591 45592 45593 52192 52204 1 8 5 1 8 5 2 9 6 3 0 7 4 7 4 1 7 4 8 5 2 9 6 3 0 6 3 0 7 2 2 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ B F K C K P C I P E K N P R S T U V W N P R S T U V W X 6 6 8 8 8 10 10 10 12 12 12 16 16 16 12 12 12 12 12 12 12 12 16 16 16 16 16 16 16 16 16 10 30 10/23 30/43 50/63 15/23 50/58 100/108 15/35 45/65 100/120 10 25/45 50/70 80/95 100/115 120/135 140/155 160/175 180/195 200/215 250/265 80/95 100/115 120/135 140/155 160/175 180/195 200/215 250/265 300/315 40 40 48/35 48/35 48/35 50/42 50/42 50/42 70/50 70/50 70/50 64 84/64 84/64 65/50 65/50 65/50 65/50 65/50 65/50 65/50 65/50 80/65 80/65 80/65 80/65 80/65 80/65 80/65 80/65 80/65 65 85 73 93 113 83 118 168 105 135 190 98 133 158 165 185 205 225 245 265 285 335 184 204 224 244 264 284 304 354 404 68 88 76 96 116 89 125 174 113 143 202 109 144 169 176 196 216 236 256 276 296 346 200 220 240 260 280 300 320 370 420 M 6 x 25 M 6 x 30 M 8 x 41 M 8 x 59 M 8 x 81 M 10 x 51 M 10 x 87 M 10 x 134 M 12 x 71 M 12 x 103 M 12 x 157 M 16 x 54 M 16 x 89 M 16 x 114 M 12 x 129 M 12 x 149 M 12 x 169 M 12 x 189 M 12 x 100 M 12 x 100 M 12 x 100 M 12 x 100 M 16 x 144 M 16 x 164 M 16 x 184 M 16 x 100 M 16 x 100 M 16 x 100 M 16 x 100 M 16 x 100 M 16 x 100 100 100 50 50 50 50 20 20 20 20 20 10 10 10 20 20 20 10 10 10 10 10 10 10 10 10 10 10 10 10 10 1) Different usable lengths for the corresponding dimensions are possible. usable length and anchorage depth before (resp. anchorage depth hef [mm] Bolt FBN II-GS (with large washer).-No. thread qty. The values for max. ID approval Imprint on head drill-Ø usable length effect. drill-hole total length depth for through fixings td [mm] l [mm] [Ø x length] pcs. zinc-plated steel min. High performance steel anchors . -No. per box do [mm] da [mm] FBN 8/5 HDG FBN 8/10 HDG FBN 8/50 HDG FBN 8/100 HDG FBN 10/5 HDG FBN 10/15 HDG FBN 10/50 HDG FBN 10/100 HDG FBN 10/140 HDG FBN 12/5 HDG FBN 12/15 HDG FBN 12/30 HDG FBN 12/45 HDG FBN 12/100 HDG FBN 16/10 HDG FBN 16/25 HDG FBN 16/50 HDG FBN 16/100 HDG 57525 57526 57527 57528 57529 57530 57531 57532 57533 57534 57535 57536 57537 57538 57539 57540 57541 57542 3 0 7 4 1 7 4 1 8 5 2 9 6 3 0 6 3 0 - 8 8 8 8 10 10 10 10 10 12 12 12 12 12 16 16 16 16 5 10 50 100 5 15 50 100 140 5 15 30 45 100 10 25 50 100 35 48 48 48 42 50 50 50 50 50 70 70 70 70 64 84 84 84 55 73 113 163 65 83 118 168 208 75 105 120 135 190 98 133 158 208 58 76 116 166 69 89 124 174 214 83 113 128 143 202 109 144.106 Bolt FBN II High performance steel anchors Technical DATA Bolt FBN HDG. drill-hole total length depth for through fixings td [mm] l [mm] [Ø x length] pcs. thread qty. FBN 8 x 75 H FBN 8 x 95 H 1) 1) 92420 92421 4 1 8 8 50 50 75 95 30 30 1. 169 221 M 8 x 23 M 8 x 41 M 8 x 81 M 8 x 130 M 10 x 31 M 10 x 51 M 10 x 87 M 10 x 134 M 10 x 174 M 12 x 41 M 12 x 71 M 12 x 86 M 12 x 103 M 12 x 137 M 16 x 54 M 16 x 89 M 16 x 114 M 16 x 166 100 50 50 25 50 50 20 20 20 20 20 20 20 20 10 10 10 10 Bolt FBN 8 H Type Art. per box [mm] [kN] pcs.-No. hot-dip galvanised steel Type Art. . anchorage depth hef [mm] min. ID drill-Ø do [mm] drill depth = mounting depth [mm] total length l [mm] length of hook failure load qty.10 50 50 1) Take a sefety factor into consideration.10 1. ID Imprint on head drill-Ø usable length effect. 2 34.5 70 11.5 120 120 200 Recommended tensile load Nperm of one singlea nchor without edge influence. Use restricted to anchoring of structural components which are statically indeterminate. For the design complete approval ETA-07/XXXX (FBN II Anchor type Effective anchorage depth in non-cracked concrete C20/252) in non-cracked concrete C20/252) Permissible bending moment Anchor characteristics Characteristics axial spacing Characteristic edge distance Minimum axial spacing Minimum edge distance Minimum structural component thickness Nominal drill diameter Drill hole depth Clearance-hole in fixture to be attached Installation torque scr.6 22.1 FBN 8 A4 353) 3.7 463) 9 15 903) 45 3) FBN 6 A4 hef Nperm Vperm Mperm [mm] [kN] [kN] [Nm] 40 3.6 3.1 315 157.107 LOADS fischer Bolt FBN A4 / FBN II Recommended Loads1) of single anchors in normal-weight concrete C20/252).5 8.2 22. edge distance c ≥ 1. For higher concrete strength classes an increase in performance of up to 55% is possible. i. i.5 8.2 FBN II 8 gvz 303) 2.5 39.2 190 95 90 80 130 16 88 18 100 250 125 100 100 170 108 FBN II 20 gvz 80 17.e.2 5.0 22.1 6.5 90 120 120 16 89 18 100 104 240 120 90 90 160 403) 403) 100 Note: With the fischer Design Software COMPUFIX you can use the full performance of the fischer Bolt FBN and you are able to do designs under individual application conditions.5 FBN II 12 gvz 50 8.6 12.8 241.N [mm] ccr.1 25.3 199. The concrete is considered to be normally reinforced.N [mm] smin [mm] cmin [mm] hmin [mm] d0 [mm] h1 ≥ [mm] df ≤ [mm] Tinst [Nm] 120 60 40 35 100 6 55 7 7.5 8.0 44.4 are considered.5 44.9 195 97.0 48 4.4 95.2 120 60 50 80 100 10 63 58 12 30 68 50 8.8 38.8 6. edge influences and influences of spacings of anchor groups are to be considered.3 195 97.1 6.5 70 70 120 FBN 12 A4 50 8.5 x hef and axial spacing s ≥ 3 x hef Recommended shear load Vperm of one single anchor without edge influence.9 12. 2) 3) High performance steel anchors .4 120 60 40 40 100 8 56 503) 9 15 1103) 553) 503) 453) 100 8 140 70 50 35 100 114.43) 12.0 FBN II 10 gvz 40 6.9 12.9 80 17.5 8.9 FBN 16 A4 64 10.9 3. annex C) if combined tensile and shear loads.5 24. edge distance c ≥ 10 x hef and axial spacing s ≥ 3 x hef 12. 1) The partial safety factors for resistance and the partial safety factor for load with YF = 1.1 6.3 114.6 150 75 50 50 100 FBN 10 A4 42 5.9 150 75 70 100 100 12 70 14 50 85 65 12.8 130 65 50 60 100 10 60 12 30 68 150 75 60 55 100 50 6.03) 40 6.0 150 75 95 95 100 12 70 14 50 90 210 105 80 75 140 FBN II 16 gvz 65 12.6 5. Please observe the design method A (ETAG.6 22.5 25.4 240 120 120 120 160 20 110 22 200 135 105 25.4 84 14.9 11.e. g. therefore particularly suitable for temporary fixings (e. countersunk head Concrete screw FBS-US. hexagon head Concrete screw FBS-M8.108 Concrete screw FBS The simple and time-saving threaded concrete screw for the cracked or tension zone. shuttering supports). ▪ Completely removable anchor. outside diameter M8 Concrete screw FBS-M8/M10. High performance steel anchors OVERVIEW Concrete screw FBS-P. internal thread M8/M10 ▪ ▪ ▪ ▪ ▪ ▪ ▪ Metal profiles Wire hangers Chains Cables Punched tapes Ventilation pipes Substructures made of wood and metal ▪ Ceilings FBS M12 Concrete screw with thread and hexagon drive. ▪ Re-usability of the screws reduces costs. FIRE PROTECTION STANDARDS Red hot: see page 308 for information about fire protection.. hexagon head withintegrated washer Concrete screw FBS-S. ▪ A4 stainless steel version for outdoor use or in damp conditions. ▪ Serrations on the thread makes the screws easy to screw in. ▪ Fixing with different head designs for different areas of application. . stainless steel Description ▪ Self-tapping concrete screw for push-through and prior insertion installation ▪ When the concrete screw is screwed into the hole. ▪ Solid sand-lime brick For fixing of: ▪ Handrails ▪ Consoles ▪ Ladders ▪ Cable trays ▪ Machines ▪ Gates ▪ Facades ▪ Window elements ▪ Battens Concrete screw FBS-SK. ▪ Virtually expansion-free operation allows cost-efficient fixing with small axial spaces and edge distances. You will find everything that has standards on page 313 under the keyword approvals. the thread taps into the concrete and creates a positive fit anchorage. panhead Approved for: ▪ Cracked and non-cracked concrete C20/25 to C50/60 ▪ Lightweight ceilings and suspended ceilings according to DIN 18168 ▪ Statically comparable fixings Also suitable for: ▪ Concrete C12/15 ▪ Natural stone with dense structure ▪ Solid brick. Advantages/benefits ▪ Setting and installation in one working operation saves time. ID approval DIBt drill-Ø do [mm] drill-hole diameter in object df [Ø mm] screw diameter ds [mm] drill hole depth anchorage depth h0 [mm] hef [mm] Concrete screw FBS-SK countersunk head. ID approval drill-Ø drill-hole diameter in object df [Ø mm] screw diameter ds [mm] min. internal thread M8/M10.6 7.5 12.6 60 60 55 55 M8 M8 SW10 SW13 100 100 Concrete screw FBS-US.109 INSTALLATION Type of installation ▪ Pre-positioned installation ▪ Push-through installation Installation tips ▪ We recommend use of an impact wrench with tangential impact (see the table for power output).6 7.6 7. per box pcs.-No. usable length t fix [mm] actuation qty. outside diameter M8. hexagon head with integrated washe Type Art. High performance steel anchors . drill-hole anchorage depth depth for through fixings td [mm] hef [mm] Concrete screw FBS-M8/M10. per box pcs. ID approval DIBt drill-Ø do [mm] drill-hole diameter in object df [Ø mm] screw diameter ds [mm] drill hole depth anchorage depth h0 [mm] hef [mm] Concrete screw FBS-S.5 12. Performance details of impact wrench Concrete screw FBS 5 FBS 6 FBS 8 FBS 10 Use nuts (black) which fit percussion power screwdrivers! recommended installation torque 100 [Nm] 200 [Nm] 300 [Nm] Technical DATA Concrete screw FBS-P panhead.5 12.5 10. FBS 5/5 P FBS 6/5 SK FBS 6/5 P FBS 6/25 P 66774 66935 66939 66948 3 8 6 8 ▯ ▯ ▯ ▯ 5 6 6 6 7 8 8 8 6. zinc-plated steel Type Art.5 7. per box DIBt do [mm] M SW pcs. hexagon head max.5 10. FBS 6 M8 FBS 6 M8/M10I 66949 66950 5 1 ▯ ▯ 6 6 8 8 7.5 90 110 100 100 110 120 105 115 75 75 75 85 85 85 85 85 5 25 15 5 15 25 10 20 T40/SW13 T40/SW13 SW 16 SW 18 SW 18 SW 18 SW 17 SW 17 100 100 100 50 50 50 50 50 CORROSION All about corrosion and how you can avoid it is written on page 309. zinc-plated steel max. zinc-plated steel thread width across nut qty. usable length t fix [mm] actuation qty.-No.5 12.-No.5 12. FBS 8/5 US FBS 8/25 US FBS 8/15 S FBS 10/5 S FBS 10/15 S FBS 10/25 S FBS 10/15 S A4 FBS 10/20 S A4 66956 66957 66958 67062 67063 67168 47465 98336 3 0 7 0 7 9 6 2 ▯ ▯ ▯ ▯ ▯ ▯ ▯ ▯ 8 8 8 10 10 10 10 10 12 12 12 14 14 14 14 14 10.6 65 65 65 65 55 55 55 55 5 5 5 25 T30 T30 T30 T30 100 100 100 100 Concrete screw FBS-M8. zinc-plated steel Type Art. For further detailed information about approvals please contact your local fischer representative. edge distance1) cmin [mm] Min.4 – 19.2 – 10.4 are included. Material safety factor γM depends on type of anchor.6 40.3 – – – – – 50 100 110 0.0 16.4 – 7. qty.1 13.4 6.-No. Design resistant loads: material safety factor γM is included. edge distance the above described loads have to be reduced! (See design software “CC-Compufix”) All load values apply for concrete C20/25 without edge or spacing influence.8 60 65 130 0. LOADS Design resistant and recommended loads for single anchors of fischer Concrete screw FBS with large axial spacing and edge distance Anchor size Effective anchorage depth Drill hole depth Screw in depth Drill hole diameter Design resistant loads NRd and VRd [kN] Tensile Shear Recommended loads Nrec and Vrec [kN] Tensile Shear 0° 90° Nrec [kN] gvz A4 gvz Vrec [kN] A4 2.110 Concrete screw FBS High performance steel anchors Technical DATA FBS M12 Concrete screw with thread and hexagon drive.4 16.5 12.6 FBS 52) 55 60 5 FBS 62) 55 60 6 Non-cracked concrete FBS 8 FBS 10 50 60 85 95 75 85 8 10 FBS 5* 55 60 55 5 Cracked concrete FBS 6* FBS 8* 55 50 60 85 55 75 6 8 FBS 10 60 95 85 10 hef h0 ≧ hnom ≧ d0 [mm] [mm] [mm] [mm] Recommended bending moment Mrec [Nm] gvz A4 Component dimensions. per box DIBt do [mm] M FBS 10 M12/30 FBS 10 M12/53 FBS 10 M12/40 A4 FBS 10 M12/60 A4 1) 1) 1) 1) 98339 98340 98337 98338 3 9 9 9 ▯ ▯ ▯ ▯ 10 10 10 10 14 14 14 14 12.4 – 19. structural component thickness hmin [mm] Mrec [Nm] * For the fixing of lightweight suspended ceiling constructions only.0 36.1 12.7 5. results are from fischer in house tests. zinc-plated steel Type Art. not pre-assembled.5 12.4 – – – 1.8 60 65 130 0° 90° NRd [kN] gvz A4 gvz VRd [kN] A4 7.1 – 7. minimum axial spacings and edge distances Min.9 19. stainless steel max. axial spacing1) smin [mm] Min. The conditions of application differ from those given in the German Approval.4 – 5.3 – 9.4 – 10. 2) Not included in any approvals.0 – 50 100 110 2.9 17.0 0.0 – 50 70 120 6. 1) For min.0 9. ID approval drill-Ø drill-hole diameter in object df [Ø mm] screw diameter ds [mm] drill hole depth anchorage depth h0 [mm] hef [mm] FBS M12 A4 Concrete screw with thread and hexagon drive. axial spacing and min. .0 36. usable length t fix [mm] thread width across nut SW pcs.4 12.4 5.0 – 50 70 120 3.5 125 148 135 155 85 85 85 85 30 53 40 60 M 12 M 12 M 12 M 12 9 9 9 9 50 50 50 50 1) Including nuts and washer.2 3.9 12. Recommended loads: material safety factor γM and safety factor for load γL = 1.5 12.9 3.1 – – – 3.6 40.8 – – – 8. the cone is pulled into the sleeve and expands it into the cavity or expands it in the solid material against the hole wall. stainless steel from size M8 Description ▪ Sleeve anchor with internal thread specially for anchoring in prestressed concrete hollow ceilings ▪ When the screw or hexagon nut is tightened. INSTALLATION Type of installation ▪ Stand-off installation ▪ Pre-positioned installation Installation tips in the SaMontec specialist catalogue. ▪ The anchor can also be installed outside the cavity axis up to 5 cm from the tensioning wire.111 Hollow-ceiling anchor FHY Specially for fixings in prestressed hollow-ceiling slabs. Advantages/benefits ▪ Suitable for cavities and solid zones of prestressed concrete hollow ceilings. ▪ No special tools necessary. ▪ A4 stainless steel version for outdoor use or in damp conditions (not part of the official approval). zinc-plated steel Approved for: ▪ Prestressed hollow-core concrete slabs C50/60 (only zinc-plated version) Also suitable for: ▪ Concrete C12/15 to C50/60 ▪ Natural stone with dense structure For fixing of: ▪ Pipes ▪ Ventilation systems ▪ Sprinkler systems ▪ Consoles ▪ Steel constructions ▪ Gratings ▪ Cable trays ▪ Gates ▪ Suspended ceilings Hollow-ceiling anchor FHY A4. ▪ Suitable for all screws or studs with metric threads. OVERVIEW Hollow-ceiling anchor FHY. High performance steel anchors . ▪ Observe the required screw-in depth e2 in the fixing when determining the bolt length Is: Minimum screw-in depth e2 + Thickness of building component tfix + Thickness of washer = Screw length ▪ Suitable bolts and studs can be found STANDARDS You will find everything that has standards on page 313 under the keyword approvals. 2 the permissible load may be interpolated linearly. FIRE PRevention CORROSION Red hot: You will find fire prevention information on page 308.2 = scr1.7 c≧ ccr1. and for statically similar anchorages up to 1.8 0.2 1.-No. stainless steel Type Art.4 10. the shearing loadbearing capacity must be reduced . edge distance Safe working bending moment Grade 4.2 < scr1.2 ≧ cmin1. zinc-plated steel Hollow-ceiling anchor FHY A4. edge distance2) Axial spacing Pairs of fixings3) Perm. = 0. For fastening lightweight ceiling coverings and underceilings.8 Grade 5.8 80 150 100 4.2 c= cmin1.2 times the web width.7 0.2 < s1. F2) with Axial spacing2) Min.74) 17.1–1711 in its entirety. the width of whose cavities is not more than 4. 4) Only threaded rods marked in accordance with the approval may be used. bolt penetration e2 [mm] max. axial spacing Edge distance Min.7 0.0 1. The permissible load for the most highly stressed fixing must not exceed the values stated for the single fixing. drill hole effect.6 2.8 21. may be assumed to be twice the permissible load for the single fixing.35 100 0.8 0. bolt penetration e1 [mm] qty.25 80 150 100 2.7 0. Rust prevention tips: Everything you need to know about corrosion and how to prevent it is on page 309.8 Length of hexagon-head screw5) Length of threaded bolt Installation torque Through-hole in the component to be attached 1) du h1 ≧ [mm] [mm] [mm] [kN] [kN] [mm] [mm] [mm] [kN] [kN] [mm] [mm] [mm] ≧ 25 < 30 FHY M 6 ≧ 30 < 40 50 10 0. shear and diagonal load at any angle in hollow-slab floors of prestressed concrete of strength class ≥ C50/60.0 kN/m 2. The fixing may also be used as multiple fastening for anchoring lightweight ceiling coverings and underceilings to DIN 18168 on hollow-slab ceilings of prestressed concrete. observe the approval Z–21.35 70 1.6 2. The linear value at s1. per box pcs. F2) with Perm. the shaft length must be ≦ tfix.112 Hollow-ceiling anchor FHY High performance steel anchors Technical DATA Hollow-ceiling anchor FHY.2 ≧ ccr1.2 ccr1. Fixing type Web thickness Drill hole depth Drill hole diameter Single fixing Perm. ≧ c≧ ccr1. F with Min.8 ≧ 40 FHY M 10 ≧ 30 ≧ 40 < 40 65 16 1.8 4.2.35 2.2 ≧ scr1. to DIN 18168. 3) The permissible load applies for a pair of fixings.35 2.4 1.0 3. For pairs of fixings with min axial distances of smin1.0 1. FHY M 6 FHY M 8 FHY M10 FHY M 6 A4 FHY M 8 A4 FHY M10 A4 30138 30146 30148 30139 30147 30151 8 3 7 5 0 7 ▯ ▯ ▯ 10 12 16 10 12 16 50 60 65 50 60 65 30 35 40 30 35 40 37 43 52 37 43 52 M6 M8 M 10 M6 M8 M 10 37 43 52 37 43 52 45 55 60 45 55 60 50 25 20 50 25 20 LOADS Safe working loads1) fixing parameters and component dimensions for tension. F with Perm. When dimensioning.2 ≧ cmin1.44) 34.0 1.04) 39 + tfix 62 + tfix 10 7 6. anchorage anchor length depth depth t [mm] hef [mm] l [mm] thread M min.9 0.14) 45 + tfix 68 + tfix 10 9 12.7 0. When external loads are suspended from the prestressed-concrete hollow-slab ceilings. 5) With hexagon bolts with shaft to DIN EN 24014. ID approval DIBt drill-Ø do [mm] min.35 70 1.4 1.6 Grade 5.3 100 min ls ≧ min lB ≧ T inst df ≦ [Nm] [Nm] [Nm] [mm] [mm] [Nm] [mm] – 4.44) 7. .2.24) 54 + tfix 77 + tfix 20 12 The anchorage of the Cavity Fixing FHY is permissible only in hollow-slab ceilings of prestressed concrete. 2) For edge distances cmin < c ≦ ccr the permissible loads may be determined by linear interpolation.8 150 100 300 ≧ 40 ≧ 25 < 30 FHY M 8 ≧ 30 < 40 60 12 0.2 c = cmin Smin1.9 0.2 for the pair of fixings with tensile load applied.25 80 150 100 2.35 100 2.0 2. this reduction is not necessary. -No. anchorage anchor length depth for through depth fixings td [mm] hef [mm] l [mm] max. the correct drilling procedure and much more on page 303. . INSTALLATION Type of installation ▪ Push-through installation Technical DATA fischer Sleeve anchor FSA-S.113 Sleeve anchor FSA OVERVIEW Sleeve anchor FSA-S Suitable for: ▪ Concrete C12/15 to C50/60 ▪ Natural stone with dense structure ▪ Good quality brick For fixing of: ▪ Steel constructions ▪ Gratings ▪ Handrails ▪ Consoles ▪ Ladders ▪ Machines ▪ Gates Sleeve anchor FSA-B Description ▪ Light sleeve anchor for push-through installation. ▪ Version FSA-S for fixings with detailed design: where no protruding thread is visual after the installation. this clamps the item being attached firmly against the concrete. High performance steel anchors The lightweight sleeve anchor for non structural and non safety critical applications. Advantages/benefits ▪ The half-moon shaped recesses stamped in the sleeve allows for contraction in length when tightened. the tapered bolt is pulled into the expansion sleeve and expands it against the hole wall. usable length t fix [mm] thread width across nut qty. ▪ When the hexagon nut or bolt is tightened. per box do [mm] M SW pcs. FSA 8/15 S FSA 8/40 S FSA 8/65 S FSA 10/10 S FSA 10/35 S FSA 10/60 S FSA 12/10 S FSA 12/25 S FSA 12/50 S 68520 68521 68522 68523 68524 68525 68526 68527 68528 4 1 8 5 2 9 6 3 0 8 8 8 10 10 10 12 12 12 65 90 115 65 90 115 75 90 115 35 35 35 40 40 40 50 50 50 69 94 119 70 95 120 81 96 121 15 40 65 10 35 60 10 25 50 M6 M6 M6 M8 M8 M8 M 10 M 10 M 10 10 10 10 13 13 13 17 17 17 50 50 50 20 20 20 20 20 20 FIXING PRINCIPLES In detail: The general principles for installation. zinc-plated steel Type Art. drill-hole effect. ID drill-Ø min. -No. For detailed design method please contact the fischer technical service department.1 16. drill-hole effect.6 10.. axial spacing1) smin [mm] Min. . M8 40 55 10 13. minimum axial spacings and edge distances Min.7 100 60 100 40 0° 90° 0° 90° 0° 90° hef [mm] h1 ≧ [mm] d0 [mm] Nu [kN] gvz Vu [kN] gvz NRd [kN] gvz VRd [kN] gvz Nrec [kN] gvz Vrec [kN] gvz FSA 8/. FSA 8/15 B FSA 8/40 B FSA 8/65 B FSA 10/10 B FSA 10/35 B FSA 10/60 B FSA 12/10 B FSA 12/25 B FSA 12/50 B FSA 12/75 B 68500 68501 68502 68503 68504 68505 68506 68507 68508 68509 6 3 0 7 4 1 8 5 2 9 8 8 8 10 10 10 12 12 12 12 65 90 115 65 90 115 75 90 115 140 35 35 35 40 40 40 50 50 50 50 65 90 115 69 94 119 81 96 121 146 15 40 65 10 35 60 10 25 50 75 M6 M6 M6 M8 M8 M8 M 10 M 10 M 10 M 10 10 10 10 13 13 13 17 17 17 17 50 50 50 20 20 20 20 20 20 20 LOADS Mean ultimate loads and recommended loads for single anchors of fischer Sleeve anchor FSA with large axial spacing and edge distance.7 4.8 3.9 80 60 80 25 25.5 FSA 12/.5 7. per box do [mm] M SW pcs. Material safety factor γM depends on type of anchor. edge distance1) cmin [mm] Min.2* 3.2 23. edge distance the above described loads have to be reduced! All load values apply for concrete C 20/25 without edge or spacing influence. M 10 50 65 12 19.4 are included.5 5.1 2.. Design resistant loads: material safety factors γM is included.0 7. anchorage anchor length depth for through depth fixings td [mm] hef [mm] l [mm] max. Recommended loads: material safety factors γM and safety factor for load γL = 1.2 70 50 70 10 12.3 5. axial spacing and min.6 7.114 High performance steel anchors Technical DATA Sleeve anchor FSA-B. M6 35 50 8 10.7 13. zinc-plated steel Type Art. ID drill-Ø min.3 5.8 * steel failure 1) For min. usable length t fix [mm] thread width across nut qty.9 4. structural component thickness hmin [mm] Required torque T inst [Nm] 5..1 Non-cracked concrete FSA 10/. Anchor size Effective anchorage depth Drill hole depth Drill hole diameter Mean ultimate loads Nu and Vu [kN] Tensile Shear Design resistant loads NRd and VRd [kN] Tensile Shear Recommended loads Nrec and Vrec [kN] Tensile Shear Recommended bending moment Mrec [Nm] Mrec [Nm] gvz Component dimensions. INSTALLATION Type of installation ▪ Push-through installation High performance steel anchors The lightweight sleeve anchor for non structural and non safety critical applications. this clamps the item being attached firmly against the concrete. ▪ When the hexagon nut or bolt is tightened.115 Sleeve anchor FSA OVERVIEW Sleeve anchor FSA GB Suitable for: ▪ Concrete C12/15 to C50/60 ▪ Natural stone with dense structure ▪ Good quality brick For fixing of: ▪ Steel constructions ▪ Gratings ▪ Handrails ▪ Consoles ▪ Ladders ▪ Machines ▪ Gates Description ▪ Sleeve anchor for push-through installation. the tapered bolt is pulled into the expansion sleeve and expands it against the hole wall. Advantages/benefits ▪ The recesses stamped in the sleeve effect contraction in length when tightened. . .. FSA GB 20/.5 M6 M6 M6 M8 M8 M8 M10 M10 M10 M10 M12 M12 M12 M16 M16 100 100 100 100 100 100 50 50 50 25 25 20 20 20 10 10 10 5 FSA GB 8/10 A2 (8x45) FSA GB 8/25 A2 (8x65) FSA GB 10/5 A2 (10x50) FSA GB 10/25 A2 (10x70) FSA GB 10/55 A2 (10x100) FSA GB 10/75 A2 (10x120) FSA GB 12/10 A2 (12x60) FSA GB 12/25 A2 (12x80) FSA GB 12/45 A2 (12x100) FSA GB 12/65 A2 (12x120) 42574 42575 42576 42577 42578 42579 42580 42581 42582 42583 0 7 4 1 8 5 2 9 6 3 8 8 10 10 10 10 12 12 12 12 - 25 30 30 35 35 35 35 40 40 40 45 65 50 70 100 120 60 80 100 120 10 25 5 25 55 75 10 25 45 65 M6 M6 M8 M8 M8 M8 M10 M10 M10 M10 100 50 50 50 50 50 25 25 20 20 LOADS Mean ultimate loads and recommended loads for single anchors of fischer Sleeve anchor FSA with large axial spacing and edge distance.5 60 10. FSA GB 10/.4 100 .. drill-hole effect.. FSA GB 12/..3 10 3. M 4.6 40 7.-No. zinc-plated steel Type Art.. Anchor size Drill hole depth Drill hole diameter Recommended loads Nrec and Vrec [kN] Tensile 0° Required Torque h1 ≧ [mm] d0 [mm] Nrec [kN] gvz [Nm] Non-cracked concrete FSA GB 6/. FSA GB 8/.5 M4.116 High performance steel anchors Technical DATA fischer Sleeve anchor FSA GB.5 M4. usable length t fix [mm] thread width across nut qty. anchorage anchor length depth for through depth fixings td [mm] hef [mm] l [mm] max. FSA GB 16/.0 25 3.5 M6 M8 M 10 M 12 M 16 30 40 45 55 60 70 6 8 10 12 16 20 2 5 2. FSA GB 6/5 (6x25) FSA GB 6/8 (6x35) FSA GB 6/25 (6x56) FSA GB 8/8 (8x40) FSA GB 8/30 (8x65) FSA GB 8/55 (8x85) FSA GB 10/10 (10x50) FSA GB 10/35 (10x70) FSA GB 10/60 (10x97) FSA GB 12/12 (12x60) FSA GB 12/20 (12x75) FSA GB 12/50 (12x99) FSA GB 12/75 (12x129) FSA GB 16/12 (16x65) FSA GB 16/50 (16x111) FSA GB 16/80 (16x147) FSA GB 20/20 (20x82) FSA GB 20/95 (20x151) 42672 42661 42662 42663 42655 42664 42665 42656 42657 42666 42658 42659 42667 42668 42660 42669 42670 42671 8 5 2 9 3 6 2 0 7 9 4 1 6 3 8 0 7 1 6 6 6 8 8 8 10 10 10 12 12 12 12 16 16 16 20 20 35 46 66 55 70 100 65 92 112 75 90 114 144 85 131 167 102 176 20 30 33 34 36 37 38 40 40 46 50 50 50 52 58 62 62 63 25 38 58 42 66 92 48 75 100 58 70 100 125 64 108 142 82 158 5 8 25 8 30 55 10 35 60 12 20 50 75 12 50 80 20 95 M4. per box do [mm] M SW pcs. ID drill-Ø min. ▪ Double-clip method tried and tested. ▪ For wooden structures use the EXA-GS with large washer as per DIN 440. zinc-plated steel Express anchor EXA. Advantages/benefits INSTALLATION Type of installation ▪ Push-through and pre-positioned installation ▪ For series installation we recommend the anchor bolt setting tool FABS to reduce installation time (Page 90). hot-dipped galvanised Express anchor EXA.117 Express anchor EXA OVERVIEW Express anchor EXA. stainless steel A4 Express anchor EXA. ▪ Minimum slippage due to powerful expansion when tightening. the hexagon nut must be brought into the optimal installation position (the thread projects by 2 to 3 mm). ▪ Before driving in. Installation tips STANDARDS You will find everything that has standards on page 313 under the keyword approvals. gives double security. ▪ A4 stainless steel and hot dip-galvanized version for outdoor use and in damp conditions. the tapered bolt is pulled into the expansion clip and expands it against the hole wall. with big washer DIN 440 Approved for: ▪ Non-cracked concrete C20/25 to C50/60 ▪ Lightweight and suspended ceilings according to DIN 18 168 as well as statically comparable fixings Also suitable for: ▪ Concrete C12/15 ▪ Natural stone with dense structure For fixing of: ▪ Steel constructions ▪ Railings ▪ Consoles ▪ Ladders ▪ Cable trays ▪ Machines High performance steel anchors ▪ ▪ ▪ ▪ ▪ Staircases Gates Facades Window elements Wooden constructions Description ▪ Express anchor for push-through and pre-positioned stallation ▪ When the hexagon nut is tightened. . 6 12 x 1. ID approvals drill-Ø thread max. per box do [mm] M [mm] tfix [mm] l [mm] pcs.118 Express anchor EXA High performance steel anchors Technical DATA Express anchor EXA. per box ■ ETA do [mm] M [mm] tfix [mm] l [mm] pcs.5 24 x 2. fixing thickness total length drill depth through Washer fixture (outer diameter x thickness) h0 [mm] [mm] qty.6 16 x 1. zinc-plated steel Type Art.5 24 x 2.6 20 x 2 20 x 2 20 x 2 24 x 2.5 24 x 2.6 16 x 1.5 100 50 50 50 50 50 50 50 25 25 25 25 FIRE PRevention CORROSION Red hot: You will find fire prevention information on page 308. stainless steel A4 Type Art. fixing thickness total length drill depth through Washer fixture (outer diameter x thickness) h0 [mm] [mm] qty.5 24 x 2.5 24 x 2.6 16 x 1.-No.6 16 x 1.6 16 x 1. EXA 6/5 (6x50) gvz EXA 6/10 (6x70) gvz EXA 6/40 (6x100) gvz EXA 8/5 (8x60) gvz EXA 8/15 (8x65) gvz EXA 8/28 (8x98) gvz EXA 8/55 (8x125) gvz EXA 8/100 (8x170) gvz EXA 10/5 (10x70) gvz EXA 10/15 (10x92) gvz EXA 10/45 (10x122) gvz EXA 10/90 (10x167) gvz EXA 10/140 (10x217) gvz EXA 10/160 (10x197) gvz EXA 12/5 (12x80) gvz EXA 12/15 (12x116) gvz EXA 12/35 (12x136) gvz EXA 12/55 (12x156) gvz EXA 12/85 (12x186) gvz EXA 12/105 (12x206) gvz EXA 12/125 (12x226) gvz EXA 12/145 (12x246) gvz EXA 12/160 (12x261) gvz EXA 16/10 (16x110) gvz EXA 16/30 (16x153) gvz EXA 16/75 (16X198) gvz EXA 16/100 (16x223) gvz EXA 16/130 (16x253) gvz EXA 16/170 (16x293) gvz EXA 16/200 (16x323) gvz EXA 20/10 (20x130) gvz EXA 20/25 (20x175) gvz EXA 20/80 (20x230) gvz 97729 97730 97731 97732 97733 97734 97735 97736 97737 97738 97739 97740 97741 97937 97742 97743 97744 97745 97746 97747 97748 97749 97750 97751 97752 97753 97754 97755 97938 97939 97756 97757 97758 3 9 6 3 0 7 4 1 8 5 2 8 5 2 2 9 6 3 0 7 4 1 7 4 1 8 5 2 9 6 9 6 3 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 6 6 6 8 8 8 8 8 10 10 10 10 10 10 12 12 12 12 12 12 12 12 12 16 16 16 16 16 16 16 20 20 20 M6 M6 M6 M8 M8 M8 M8 M8 M 10 M 10 M 10 M 10 M 10 M 10 M 12 M 12 M 12 M 12 M 12 M 12 M 12 M 12 M 12 M 16 M 16 M 16 M 16 M 16 M 16 M 16 M 20 M 20 M 20 5 10 40 5 15 28 55 100 5 15 45 90 140 160 5 15 35 55 85 105 125 145 160 10 30 75 100 130 170 200 10 25 80 50 70 100 60 85 98 125 170 70 92 122 167 217 237 80 116 136 156 186 206 226 246 261 110 153 198 223 253 293 323 130 175 230 45 70 100 60 80 95 120 165 65 85 115 160 210 230 75 105 125 145 175 195 215 235 250 100 140 185 210 240 280 310 110 155 210 12 x 1.5 24 x 2.6 16 x 1. ID drill-Ø thread max.6 16 x 1. EXA 6/10 (6x70) A4 EXA 8/5 (8x60) A4 EXA 8/15 (8x82) A4 EXA 8/55 (8x122) A4 EXA 8/100 (8x167) A4 EXA 10/15 (10x90) A4 EXA 10/45 (10x120) A4 EXA 10/90 (10x165) A4 EXA 12/15 (12x113) A4 EXA 12/55 (12x153) A4 EXA 12/85 (12x183) A4 EXA 12/105 (12x203) A4 97780 97781 97782 97783 97945 97785 97787 97788 97790 97791 97946 97947 4 1 8 5 7 9 3 0 3 0 4 1 6 8 8 8 8 10 10 10 12 12 12 12 M6 M8 M8 M8 M8 M 10 M 10 M 10 M 12 M 12 M 12 M 12 10 5 15 55 100 15 45 90 15 55 85 105 70 60 85 125 170 92 122 167 116 156 186 206 70 60 80 120 165 85 115 160 105 145 175 195 12 x 1.5 24 x 2.5 24 x 2.6 16 x 1.5 24 x 2.5 24 x 2.5 24 x 2.5 30 x 3 30 x 3 30 x 3 30 x 3 30 x 3 30 x 3 30 x 3 37 x 3 37 x 3 37 x 3 100 100 100 50 50 50 50 50 50 50 50 50 25 25 25 25 25 25 25 25 25 25 25 20 10 20 20 20 10 10 10 10 10 Express anchor EXA.6 12 x 1.6 20 x 2 20 x 2 20 x 2 20 x 2 20 x 2 20 x 2 24 x 2.-No.6 16 x 1. Rust prevention tips: Everything you need to know about corrosion and how to prevent it is on page 309. . per box do [mm] M [mm] tfix [mm] l [mm] pcs.5 24 x 2. hot-dip galvanized Type Art.qty.6 16 x 1.5 30 x 3 30 x 3 37 x 3 25 25 10 10 10 Express anchor EXA. EXA 6/5 (6x50) fvz EXA 6/10 (6x70) fvz EXA 8/5 (8x60) fvz EXA 10/5 (10x70) fvz EXA 10/15 (10x92) fvz EXA 10/45 (10x122) fvz EXA 10/90 (10x167) fvz EXA 12/5 (12x80) fvz EXA 12/15 (12x116) fvz EXA 12/35 (12x136) fvz EXA 12/55 (12x156) fvz EXA 12/85 (12x186) fvz EXA 16/10 (16x110) fvz EXA 16/30 (16x153) fvz EXA 20/25 (97779) fvz 97764 97765 97766 97767 97768 97769 97770 97771 97772 97773 97774 97775 97776 97778 97779 4 1 8 5 2 9 5 2 9 6 3 0 7 1 8 6 6 8 10 10 10 10 12 12 12 12 12 16 16 20 M6 M6 M8 M 10 M 10 M 10 M 10 M 12 M 12 M 12 M 12 M 12 M 16 M 16 M 20 5 10 5 5 15 45 90 5 15 35 55 85 10 30 25 50 70 60 70 92 122 167 80 116 136 156 186 110 153 175 50 70 60 65 85 115 160 75 105 125 145 175 100 140 155 12 x 1.119 Technical DATA Express anchor EXA. EXA 12/85 (12x186) EXA 12/105 (12x206) EXA 12/125 (12x226) EXA 12/145 (12x246) EXA 12/170 (12x271) EXA 12/250 (12x351) EXA 16/75 (16x198) EXA 16/100 (16x223) EXA 16/130 (16x253) EXA 16/170 (16x293) EXA 16/200 (16x323) 97796 97759 97760 97761 97762 97763 97940 97941 97942 97943 97944 5 0 6 3 0 7 2 9 6 3 0 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 12 12 12 12 12 12 16 16 16 16 16 M 12 M 12 M 12 M 12 M 12 M 12 M 16 M 16 M 16 M 16 M 16 85 105 125 145 170 250 75 100 130 170 200 186 206 226 246 268 350 198 223 253 293 323 175 195 215 235 250 342 185 210 240 280 310 44 x 4 44 x 4 44 x 4 44 x 4 44 x 4 44 x 4 50 x 5 50 x 5 50 x 5 50 x 5 50 x 5 25 25 25 25 25 25 20 20 20 10 10 High performance steel anchors . per box fixture ter x thickness) h0 [mm] [mm] pcs.5 24 x 2. EXA 12/145 (12x243) A4 EXA 12/160 (12x258) A4 EXA 16/10 (16x110) A4 EXA 16/30 (16x153) A4 EXA 20/25 (20x175) A4 97948 97949 97793 97794 97795 8 5 4 1 8 12 12 16 16 20 M 12 M 12 M 16 M 16 M 20 145 160 10 30 25 246 261 110 153 175 235 250 100 140 155 24 x 2.-No.5 24 x 2.5 24 x 2. ID drill-Ø do [mm] thread M [mm] max.-No.6 12 x 1. fixing thickness total length drill depth through fixture h0 [mm] washer (outer diameter x thickness) [mm] qty. per box ■ ETA do [mm] M [mm] l [mm] pcs. ID drill-Ø thread max. stainless steel A4 Type Art. fixing thickness tfix [mm] total length l [mm] drill depth through washer (outer diame. fixing thickness tfix [mm] total length drill depth through washer fixture (outer diameter x thickness) h0 [mm] [mm] qty. with big washer DIN 440 Type Art.6 20 x 2 20 x 2 20 x 2 20 x 2 24 x 2.5 30 x 3 30 x 3 37 x 3 100 100 50 50 50 50 50 25 25 25 25 25 20 10 10 Express anchor EXA.5 24 x 2.-No. ID approvals drill-Ø thread max. 8 99. Type Material gvz Effective anchorage depth hef [mm] Drill hole depth h1 [mm] Drill diameter d0 [mm] Recommended loads in concrete C20/25 Recommended load Frec [kN] Recommended bending moment Mrec [kN] 12.3 25.2 8. edge distance cmin [mm] Min.7 11. Recommended loads: Material safety factors γM and safety factor for load γL = 1.0 15.9 194.9 Component dimensions. minimum axial spacings and edge distances smin [mm] gvz 45 Min.0 15. structural component thickness hmin [mm] 100 Required torque T inst [Nm] 14 1) * steel failure decisive For min.9 18.4 Shear 90° Vrec [kN] gvz 6. axial spacing smin [mm] Min. edge distance the above described loads have to be reduced! (See “Technical Handbook” or design software “CC-Compufix”) All load values apply for Non-cracked concrete C20/25 without edge and spacing influences.6 82.3* 9. axial spacing and min.6 340 170 220 ≦14 65 EXA M 10 A4 gvz 67 90 12 0.6 11.4 180 90 150 ≦9 23 25.1 57.7 75 90 90 75 135 65 M16 85 110 16 52. structural component thickness hmin [mm] Clearance hole in fixture to be attached df [mm] Required torque T inst [Nm] EXA M8 A4 47 65 8 0.7 M10 49 70 10 22.8 85 145 90 145 170 110 M20 103 130 20 70.4 are included. minimum axial spacings and edge distances Min.3 38.7 Component dimensions.9 58.0 32.7 EXA M 12 A4 . design and recommended loads for single anchors of fischer Express anchor EXA with large axial spacing and edge distance Anchor size Effective anchorage depth Drill hole depth Drill hole diameter Mean ultimate loads Nu and Vu [kN] Tensile 0° Shear 90° M8 47 65 8 16.0 23.120 Express anchor EXA High performance steel anchors LOADS Mean ultimate loads.7* 26.0 46.9 8.7 36.2 Recommended bending moment Mrec [Nm] Mrec [Nm] gvz 12.8 26.4 260 130 200 ≦12 45 gvz 49 70 10 0. For further detailed information about European Technical Approvals please contact fischer technical service department. axial spacing1) for c ≧ [mm] gvz 60 cmin [mm] gvz 40 Min.8* 6.8 27.8 46. Design resistant loads: Material safety factors γM are included.9* 35. edge distance1) for s ≧ [mm] gvz 100 Min.2 23.8 50 85 65 100 100 45 Non-cracked concrete M12 67 90 12 35.1 40.8 13.7 105 170 100 170 205 230 hef [mm] h1 ≧ [mm] d0 [mm] Nu [kN] gvz Vu. Recommended loads for single anchors of fischer Express anchor EXA for the anchorage of lightweight ceilings and suspended ceilings (multiple fixing). Materal safety factor γM depends on type of anchor.3 10. [kN] gvz Design resistant loads NRd and VRd [kN] Tensile 0° NRd [kN] gvz Shear 90° VRd [kN] gvz Recommended loads Nrec and Vrec [kN] Tensile 0° Nrec [kN] gvz 4.9* 15.5 6. INSTALLATION Installation tips For the best results with the GM anchor remember to: ▪ Choose the most suitable head type. ▪ Choose the right sized anchor in relation to load type. ▪ Torque controlled friction locking expansion. ▪ Ventilation ducts ▪ Pipework ▪ Suspended ceilings ▪ Metal profiles ▪ Shelf feet Also suitable for: ▪ temporary fastenings such as wall shuttering Wallbolt GM L loose bolt type Wallbolt GM P projecting bolt type Wallbolt GM E closed eye Description The segmented malleable iron expansion shield is assembled ready for use with bolts or threaded rods of the appropriate diameter. ▪ Make sure the drilled hole is dust free. ▪ Traditional fixing method accepted widely by end users. High performance steel anchors . ▪ Four piece malleable shield for even load spread. STANDARDS You will find everything that has standards on page 313 under the keyword approvals. For fixing of: ▪ Installation rails. ▪ Check load bearing capacity values in the table.121 Wallbolt GM Professional Wallbolt OVERVIEW Wallbolt GM S shield only Approved for: ▪ Concrete ≥B15 and natural stone with dense structure. ▪ Unique metal spring clip for retaining the segments and the wedge. ▪ Zinc plated and passivated for protection against corrosion. anchorage depth [mm] bolt Ø [mm] Fixing thickness min max [mm] [mm] torque qty.fc = 25Nm/mm2 . loose bolt zinc plated and passivated Type Art.90 200 125 100 65 100 GM12 8. .5 10 25 40 75 50 50 25 15 LOADS Recommended loads Nrec [kN] Loads in concrete cl.5 11 12.-No. ID drill Ø [mm] min..8 4. drill-hole depth [mm] min. All about corrosion and how you can avoid it is written on page 309.-No. shield only zinc plated and passivated Wallbolt GM P. 8.-No. 80 80 Min edge dist. Type Art. anchorage depth [mm] bolt Ø [mm] Fixing thickness min max [mm] [mm] torque qty. drill-hole depth [mm] min. per box pcs.122 Wallbolt GM High performance steel anchors Technical DATA Wallbolt GM S. ID drill Ø [mm] min.65 400 285 230 140 230 Critical edge distance and critical spacing [mm] Axial spacing a 140 170 Edge spacing ar 95 100 Min axial sp. 50 50 Min struct. thickness t 100 100 FIRE PROTECTION CORROSION Red hot: see page 308 or information about fire protection. drill-hole depth [mm] min. Nm GM 6 E GM 8 E GM 10 E GM 12 E 42616 42617 42618 42619 12 15 18 22 60 70 80 100 47 50 60 75 6 8 10 12 10. per box pcs. per box pcs. projecting bolt zinc plated and passivated Type Art.40 250 155 125 80 125 GM16 13. ID drill Ø [mm] min. zinc plated and passivated Type Art.-No.65 GM10 5.00 GM8 4. ID drill Ø [mm] min. Nm Nm GM 6 S GM 8 S GM 10 S GM 12 S 42624 42625 42626 42627 12 15 18 22 60 70 80 100 47 50 60 75 6 8 10 12 - - 10 25 40 75 50 50 25 20 Wallbolt GM L. GM 6/10P GM 6/25P GM 6/60P GM 8/10P GM 8/25P GM 8/60PL GM 10/15P GM 10/30P GM 10/60P GM 12/15P GM 12/35P GM 12/75P 42602 42603 42604 42605 42606 42607 42608 42609 42610 42611 42612 42613 12 12 15 15 15 18 18 18 18 22 22 22 60 60 70 70 70 80 80 80 80 100 100 100 47 47 50 50 50 60 60 60 60 75 75 75 6 6 8 8 8 10 10 10 10 12 12 12 0 0 0 0 0 0 0 0 0 0 0 0 10 26 60 10 25 60 15 30 60 15 35 75 10 10 25 25 25 40 40 40 40 75 75 75 50 50 50 50 50 50 50 50 25 25 25 25 Nm GM 6/10L GM 6/25L GM 6/40L GM 8/10L GM 8/25L GM 8/40L GM 10/10L GM 10/25L GM 10/50L GM 10/75L GM 12/10L GM 12/25L GM 12/50L GM 12/75L 42585 42586 42587 42588 42589 42590 42591 42592 42593 42594 42595 42596 42597 42598 12 12 12 15 15 15 18 18 18 18 22 22 22 22 60 60 60 70 70 70 80 80 80 80 100 100 100 100 47 47 47 50 50 50 60 60 60 60 75 75 75 75 6 6 6 8 8 8 10 10 10 10 12 12 12 12 0 0 0 0 0 0 0 0 0 25 0 0 0 25 10 25 40 10 25 40 10 25 50 75 10 25 50 75 10 10 10 25 25 25 40 40 40 40 75 75 75 75 50 50 50 50 50 50 50 50 50 25 25 25 25 25 Wallbolt GM E. anchorage depth [mm] bolt Ø [mm] eye Ø [mm] torque qty.a min.40 315 215 170 105 175 GM20 20. drill-hole depth [mm] min. per box pcs. anchorage depth [mm] bolt Ø [mm] Fixing thickness min max [mm] [mm] torque qty. ar min.5 15.kN Anchor type GM6 Bolt cl. ▪ Versitile heavy duty anchor. To determine the screw length Is : Length of the Heavy duty anchor FWB + thickness of the building component da = length of screw. (if using threaded bolts remember to include + thickness of washer and nut) FIXING PRINCIPLES In detail: The general principles for installation. ▪ Traditional fixing method accepted widely by end users. High performance steel anchors The economical heavy duty anchor . ▪ Three piece shield for even load spread.5. ▪ Screw . the correct drilling procedure and much more on page 303. ▪ Function . ▪ Zinc plated and passivated for protection against corrosion.8 steel INSTALLATION Type of installation ▪ Flush fixing Installation tips For the best results with the FWB anchor remember to: ▪ Choose the most suitable head.123 Wallbolt FWB OVERVIEW Wallbolt FWB S Shield only Wallbolt FWB L Loose bolt Wallbolt FWB P Projecting bolt Wallbolt FWB H Hook bolt Suitable for: ▪ Concrete ≥ B15 ▪ Dense natural stone ▪ Dense solid stone ▪ Good quality masonry For fixing of: ▪ Installation rails ▪ Ventilation ducts ▪ Pipework ▪ Suspended ceilings ▪ Metal constructions ▪ Metal profiles Also suitable for temporary fixings such as wall shuttering Wallbolt FWB E Eye bolt Description The segmented steel expansion shield is pre-assembled ready for use with various head Types. ▪ Choose the right sized anchor in relation to load type. ▪ Check load bearing capacity values. ▪ Make sure the drilled hole is dust free.torque controlled friction locking expansion. FWB 6/10L FWB 6/25L FWB 6/40L FWB 8/10L FWB 8/25L FWB 8/40L FWB 10/10L FWB 10/25L FWB 10/50L FWB 10/75L FWB 12/10L FWB 12/25L FWB 12/40L FWB 12/60L FWB 16/15L FWB 16/30L FWB 16/60L FWB 20/60L FWB 20/100L 42677 42678 42679 42680 42681 42682 42683 42684 42685 42686 42687 42688 42689 42690 42691 42692 42693 42694 42695 12 12 12 14 14 14 16 16 16 16 20 20 20 20 25 25 25 32 32 50 50 50 55 55 55 65 65 65 65 85 85 85 85 130 130 130 150 150 45 45 45 50 50 50 60 60 60 60 75 75 75 75 115 115 115 130 130 6 6 6 8 8 8 10 10 10 10 12 12 12 12 16 16 16 20 20 0 0 0 0 0 0 0 0 0 25 0 0 0 25 0 0 25 20 60 10 25 40 10 25 40 10 25 50 75 10 25 50 60 15 30 60 60 100 10 10 10 25 25 25 40 40 40 40 75 75 75 75 180 180 180 345 345 25 25 25 25 25 25 25 25 25 25 25 25 25 25 10 10 10 10 10 FWB 6 S FWB 8 S FWB 10 S FWB 12 S FWB 16 S FWB 20 S 51302 42673 42674 42675 51303 42676 12 14 16 20 25 32 50 55 65 85 130 150 45 50 60 75 115 130 6 8 10 12 16 20 - - 10 25 40 75 180 345 50 50 50 25 10 10 Wallbolt FWB H. drill-hole depth [mm] min.fc = 25Nm/mm2 .kN Anchor type FWB6 Drill diameter [mm] 12 Minimum drill hole depth [mm] 50 Tightening Torque [Nm] 10 Recommended Load [kN] 3 In concrete Nm pcs. per box pcs. FWB 6/10P FWB 6/25P FWB 6/60P FWB 8/10P FWB 8/25P FWB 8/60PL FWB 10/15P FWB 10/30P FWB 10/60P FWB 12/15P FWB 12/35P FWB 12/75P FWB 16/15P FWB 16/35P FWB 16/75P FWB 20/15P FWB 20/30P FWB 20/100P 42696 42697 42698 42699 42700 42701 42702 42703 42704 42705 42706 42707 42708 42709 42710 42711 42712 42713 12 12 12 14 14 14 16 16 16 20 20 20 25 25 25 32 32 32 50 50 50 55 55 55 65 65 65 85 85 85 130 130 130 150 150 150 45 45 45 50 50 60 60 60 60 75 75 75 115 115 115 130 130 130 6 6 6 8 8 8 10 10 10 12 12 12 16 16 16 20 20 20 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 10 25 60 10 25 60 15 30 60 15 35 75 15 35 75 15 30 100 10 10 10 25 25 25 40 40 40 75 75 75 180 180 180 345 345 345 50 50 50 50 50 25 50 25 25 25 25 25 10 10 10 10 10 10 FWB8 14 55 25 4 FWB10 16 65 40 5 FWB12 20 85 75 6 FWB16 25 130 180 10 FWB20 32 150 345 16 . per box Nm Nm pcs. anchorage depth [mm] bolt Ø [mm] Fixing thickness min max [mm] [mm] torque qty. loose bolt zinc plated and passivated Wallbolt FWB S. projecting bolt zinc plated and passivated Type Art. per box 12 14 16 20 12 14 16 20 25 50 55 65 85 60 70 80 100 130 45 50 60 75 47 50 60 75 102 6 8 10 12 6 8 10 12 16 8 10 12 16 12 12 15 24 19 10 25 40 75 10 25 40 75 180 50 50 25 25 50 50 25 15 10 LOADS Recommended loads Nrec [kN] Loads in concrete cl.-No.-No. drill Ø [mm] min.-No. drill Ø [mm] min. drill-hole depth [mm] min. drill Ø [mm] min. eye bolt zinc plated and passivated Type Art. Type Art.124 Wallbolt FWB High performance steel anchors Technical DATA Wallbolt FWB L. hook zinc plated and passivated Wallbolt FWB E. depth anchorage depth [mm] [mm] bolt Ø [mm] hook /eye torque qty. FWB 6 H FWB 8 H FWB 10 H FWB 12 H FWB 6 E FWB 8 E FWB 10 E FWB 12 E FWB 16 E 42719 42720 42721 42722 42714 42715 42716 42717 42718 Wallbolt FWB P. drill-hole anchorage depth depth [mm] [mm] bolt Ø [mm] Fixing thickness min max [mm] [mm] torque qty. drill-hole min.-No. shield only zinc plated and passivated Type Art. per box [mm] Nm pcs. drill Ø [mm] min. anchorage depth [mm] bolt Ø [mm] Fixing thickness min max [mm] [mm] torque qty. min. stainless steel Description ▪ Hammerset anchor with internal thread for pre-positioned installation ▪ When the cone is driven in with the Hammerset tool EAW H. zinc-plated steel Approved for: ▪ Non-cracked concrete C20/25 to C50/60 ▪ Lightweight and suspended ceilings according to DIN 18168 as well as statically comparable fixings Also suitable for: ▪ Concrete C12/15 ▪ Natural stone with dense structure For fixing of: ▪ Pipes ▪ Ventilation systems ▪ Sprinkler systems ▪ Gratings ▪ Cable trays ▪ Suspended ceilings from size M8 Hammerset anchor EA II A4. the anchor sleeve is spreaded and thus expand against the hole wall. STANDARDS You will find everything that has standards on page 313 under the keyword approvals. High performance steel anchors .125 Hammerset anchor EA II The simple hammerset anchor with internal thread. ▪ Low anchorage depth reduces drilling time and thus costefficient installation. ▪ For fixing diamond drills and diamond saws. ▪ A4 stainless steel version for outdoor use and in damp conditions. Advantages/benefits ▪ Suitable for all screws or studs with metric thread. use the special EA II M 12 D with reinforced anchor sleeve or the FDBB special fixing. ▪ Surface-flush anchor allows the attached item to be removed and refitted several times. OVERVIEW Hammerset anchor EA II. INSTALLATION Type of installation Installation tips ▪ Pre-positioned installation ▪ Observe the minimum and maximum screw-in depths when selecting the screws. bolt penetration e2 [mm] max. stainless steel Type Art. specially for diamond drilling devices and diamond saws Type Art. EA II M 6 EA II M 8 EA II M 8 x 40 EA II M 10 x 30 EA II M 10 EA II M 12 EA II M 16 EA II M 20 EA II M 6 A4 EA II M 8 A4 EA II M 8 x 40 A4 EA II M 10 A4 EA II M 12 A4 EA II M 16 A4 EA II M 20 A4 48264 48284 48323 48332 48339 48406 48408 48409 48410 48411 48412 48414 48415 48416 48417 3 1 7 9 8 7 1 8 4 1 8 2 9 6 3 8 10 10 12 12 15 20 24 8 10 10 12 15 20 24 32 33 43 33 43 54 70 85 32 33 43 43 54 70 85 30 30 40 30 40 50 65 80 30 30 40 40 50 65 80 30 30 40 30 40 50 65 80 30 30 40 40 50 65 80 6 8 8 10 10 12 16 20 6 8 8 10 12 16 20 8 10 10 12 12 14 18 23 8 10 10 12 14 18 23 12 13 13 12 16 22 28 34 12 13 13 16 22 28 34 100 100 50 50 50 25 20 10 100 100 50 50 25 20 10 Hammerset tools EAW H Plus Type Art.-No. EAW H 6 Plus EAW H 8 x 30 Plus EAW H 8 x 40 Plus EAW H 10 Plus EAW H 12 Plus EAW H 16 Plus EAW H 20 Plus 44630 44631 44632 44633 44634 44635 44636 0 7 4 1 8 5 2 EA M 6/ TL M5 / FDA-R 6 EA M 8/TL M8/FDA-R 8 EA M 8 x 40 EA M 10 /TL M10 EA M 12 / TL M12 EA M 16 / TL M16 EA M 20 1 1 1 1 1 1 1 . per box pcs.-No. per box pcs. ID approval ETA drill-Ø do [mm] min. ID approval ETA drill-Ø do [mm] min. zinc-plated steel. EA II M 12 D 48407 4 16 54 50 50 12 14 22 25 Hammerset anchor EA II. drill hole effect. bolt penetration e2 [mm] max. drill hole effect. ID fits qty. bolt penetration e1 [mm] qty. bolt penetration e1 [mm] qty.126 Hammerset anchor EA II High performance steel anchors Technical DATA Hammerset anchor EA II. per box pcs. zinc-plated steel Hammerset anchor EA II A4.-No. anchorage anchor length depth depth t [mm] hef [mm] l [mm] thread M min. anchorage anchor length depth depth t [mm] hef [mm] l [mm] thread M min. 9 3.9 6. the minimum structural component thickness hmin2 are valid along with the minimum spacing and edge distance smin2 bzw.8 40 1. shear load and oblique tensile load at any angle.N [mm] = 3 x hef Characteristic edge distance ccr. i.8 EA II M10 x 30 gvz 8.8 A4-70 5.6 17.1 29.9 17.9 90 45 1002) 652) 1152) 802) 2002) 150 8 32 6 13 7 4 2) 5.1 120 60 1002) 952) 1402) 802) 2002) 150 10 43 8 13 9 8 2) 11.9 21.8 EA II M10 gvz 8.8 30 1.3 6.0 10.8 8.single anchor of multiple fixing Permissible loads1) of a single anchor of a multiple fixing in normal-weight concrete C20/25 to C50/60.9 6. cmin1.6 A4 A4-70 Permissible load Fperm1) of a single anchor of a multiple fixing without edge influence according to ETAG 001-6 [Nm] scr [mm] ccr [mm] hmin1 [mm] smin1 [mm] cmin1 [mm] hmin2 [mm] smin2 [mm] cmin2 [mm] d0 [mm] h1 ≥ [mm] min ℓs [mm] max ℓs [mm] df ≤ [mm] max Tinst [Nm] 4.8 EA II M8 gvz 8.8 8. Along with reduction of the load at the same time.4 are considered.8 A4-70 5.5 2. For higher concrete strength classes an increase in performance of up to 55 % is possible.1 8.8 40 2.e.1 3.7 A4 A4-70 5.2 Recommended shear load Vperm of one single anchor without edge influence.8 50 3.1 90 45 1002) 952) 1402) 802) 2002) 150 10 33 8 13 9 8 2) 11.7 1.2 3.8 37.9 5.9 4.7 1. cmin2.8 EA II M12 gvz 8. Please observe the design method A (ETAG.9 3.8 8.7 Anchor characteristics Characteristic spacing scr.0 8.5 18.8 8.8 A4-70 5.0 300 150 1202) 1452) 2002) 1002) 3002) 3002) 15 54 12 22 14 35 42.8 21.6 3.8 8.8 hef Fperm [mm] [kN] 1.8 30 1. 2) 3) 4) fischer Hammerset anchor EA II . i.3 90 45 1202) 852) 1402) 802) 2002) 150 12 33 10 13 12 15 2) 23.7 1.127 LOADS fischer Hammerset anchor EA II Recommended loads1) of single anchors in normal-weight concrete C20/252) For the design the complete approval ETA-07/0135 is to be observed Anchor type M6 M8x30 M8x40 M10x30 M10 M12 M16 M20 gvz A4 A4 gvz A4 A4 gvz A4 gvz A4 gvz A4 gvz A4 Quality of the used screw 5.1 34.9 10. edge influences and influences of spacings of anchor groups are to be considered.3 21.N [mm] = 1. The concrete is considered to be normally reinforced. Use restricted to anchoring of structural components which are statically indeterminate.1 The loads are valid axial tensile load. Anchor type Quality of the used screw Effective embedment depth in cracked and non-cracked concrete C20/25 to C50/60 Permissible bending moment Mperm Mperm Anchor characteristics Characteristic spacing Characteristic edge distance Minimum structural component thickness Minimum spacing Minimum edge distance Minimum structural component thickness Minimum spacing Minimum edge distance Nominal drill hole diameter Drill hole depth Minimum screw penetration depth Maximum screw penetration depth Clearance-hole in fixture to be attached Maximum torque 1) EA II M6 gvz 5. The minimum structural component thickness hmin1 are valid along with the minimum spacing and edge distance smin1 bzw.5 12. edge distance ≥ 1.8 A4-70 5.4 are considered.8 A4-70 Effective embedment depth hef [mm] 30 30 40 30 40 50 65 80 Recommended tensile load Nperm of one single anchor without edge influence.8 8.1 8.8 30 1.3 200 100 1202) 952) 1602) 802) 2502) 200 12 43 10 17 12 15 2) 23. Material safety factors according to the approval and safety factor for load = Y 1.6 3.8 8.8 A4-70 5.0 A4 A4-70 5. annex C) if combined tensile and shear loads. 2) High performance steel anchors .5 A4 A4-70 5.8 8.5 x hef 3) Minimum spacing smin [mm] 65 95 95 85 95 145 180 190 Minimum edge distance3) cmin [mm] 115 140 140 140 160 200 240 280 Minimum structural component thickness hmin [mm] 100 100 100 120 120 120 160 200 Nominal drill hole diameter d0 [mm] 8 10 10 12 12 15 20 25 Drill hole depth h1 ≥ [mm] 32 33 43 33 43 54 70 85 Minimum screw penetration depth min ℓs [mm] 6 8 8 10 10 12 16 20 Maximum screw penetration depth max ℓs [mm] 13 13 13 13 17 22 28 34 Clearance-hole in fixture to be attached df ≤ [mm] 7 9 9 12 12 14 18 22 Maximum torque max Tinst [Nm] 4 8 8 15 15 35 60 120 Note: With the fischer Design Software COMPUFIX you can see the full performance of the EA II and you are able to do designs under individual conditions.8 EA II M8 x 40 gvz 8.7 60.5 x hef and spacing s ≥ 3 x hef 2) in non-cracked concrete C20/25 Vperm [kN] 3.9 17.7 A4 A4-70 5. 1) The partial safety factors for resistance and the partial safety factor for load with YF =1.9 6. For the design the complete approval ETA-07/0142 is to be observed.1 34.7 A4 A4-70 5.8 A4-70 5. edge distance ≥ 10 x hef and spacing s ≥ 3 x hef in non-cracked concrete C20/252) Nperm [kN] 2.8 A4-70 5.1 33.e. FIXING PRINCIPLES In detail: The general principles for installation. ▪ Suitable for all screws or studs with metric threads.not requireing approvals. ▪ Suitable for non-cracked concrete and for anchoring light ceiling linings and suspended ceilings.128 Drop-in anchor TL The economical hammerset anchor with internal thread . ▪ Surface-flush anchor allows the attached item to be removed and refitted several times. . High performance steel anchors OVERVIEW Drop-in anchor TL Suitable for: ▪ Non-cracked concrete C12/15 ▪ Natural stone with dense structure For fixing of: ▪ Pipes ▪ Ventilation systems ▪ Sprinkler systems ▪ Consoles ▪ Steel constructions ▪ Gratings ▪ Cable trays ▪ Facades ▪ Suspended ceilings Description ▪ Drop-in anchor with internal thread for pre-positioned installation. ▪ When the expander plug is driven in with EAW H Plus setting tool. ▪ Low anchoring depth reduces drilling time and thus costefficient installation. ▪ Oberserve the minimum and maximum screw-in depths when selecting the screws. Advantages/benefits INSTALLATION Type of installation Installation tips ▪ Pre-positioned installation ▪ Use fischer EAW H Plus setting tool. the anchor sleeve is expanded and is tensioned against the hole wall. the correct drilling procedure and much more on page 303. 0 60 Drop-in Anchor FDA-R OVERVIEW Drop-in anchor FDA-R Suitable for: ▪ Concrete B 15 and dense natural stone For fixing of: ▪ Pipes ▪ Ventilation systems ▪ Cable trays etc Description ▪ Drop-in anchor with internal thread for pre-positioned installation ▪ The rim ensures the anchor remains flush with the surface at all times Advantages/benefits ▪ Suitable for all screws or studs with metric thread. bolt penetration e1 [mm] qty. Use 80% of EA loads in table above. depth for through fixing [mm] Fixing length [mm] qty.-No. ID drill-Ø do [mm] min. FDA-R FDA-R 6x25 FDA-R 8x30 FDA-R 10x30 42630 42631 42632 8 10 12 27 32 33 25 30 30 1 1 1 Setting tool as EA Setting tool as 48487 High performance steel anchors . drill hole effect.129 Technical DATA Drop-in anchor TL Type Art.3 15 TL M 12 4.-No. per box pcs. per box pcs. EAW H 6 EAW H 8 EAW H 8 x 40 EAW H 10 EAW H 12 EAW H 16 EAW H 20 60836 60837 60846 60838 60839 60841 60843 4 1 3 8 5 8 2 EA M 6 EA M 8 EA M 8 x 40 EA M 10 EA M 12 EA M 16 EA M 20 1 1 1 1 1 1 1 LOADS Anchor size Recommended tensile load Maximum torque Nrec [kN] T inst [Nm] TL M 6 1. [mm] Min. bolt penetration e2 [mm] max. anchorage anchor length depth depth t [mm] hef [mm] l [mm] thread M min. ▪ Surface-flush anchor allows the attached item to be removed and refitted several times.1 8 TL M 10 3. not dependant on hole depth LOADS Mean Ultimate loads in kN. ID fits qty. Dill dia. TECHNICAL DATA Type Art. A rim for the accurate setting of the anchor flush to the surface. per box pcs.5 4 TL M 8 2.-No.8 35 TL M 16 7. TL Drop-in M 6 TL Drop-in M 8 TL Drop-in M 10 TL Drop-in M 12 TL Drop-in M 16 EA M 16 N EA M 20 N 42633 42634 42635 42636 42637 90163 90164 2 9 6 3 0 2 9 8 10 12 15 20 20 25 25 30 40 55 65 65 80 25 30 40 50 65 65 80 25 30 40 50 65 65 80 M6 M8 M 10 M 12 M16 M 16 M 20 6 8 10 12 16 16 20 12 13 17 22 27 23 34 100 100 50 50 20 25 25 Hammerset tools EAW H Type Art. ▪ Forced expansion guarantees minimum slippage under load. .-No. Concrete strength C20/25 to C50/60 per fixing With fire-resistance time F 60 With fire-resistance time F 90 Axial spacing Edge distance Minimum component thickness [kN] [kN] [kN] [mm] [mm] [mm] FDN 6 0. per box pcs. FDN 6/35 FDN 6/65 78644 78645 4 1 ▯ ▯ 6 6 45 75 32 32 39 69 4. ▪ When the expansion wedge is driven in. drill hole depth effect. High performance steel anchors OVERVIEW Ceiling nail FDN Approved for: ▪ Lightweight ceilings and suspended ceilings according to DIN 18168 ▪ Statically comparable fixings in concrete C20/25 to C50/60 Also suitable for: ▪ Concrete C12/15 ▪ Natural stone with dense structure ▪ Solid brick ▪ Solid sand-lime brick ▪ Prestressed hollow-core concrete slabs For fixing of: ▪ Battens ▪ Metal profiles ▪ Wire hangers ▪ Chains ▪ Punched tapes ▪ Ventilation pipes ▪ Substructures made of wood and metal ▪ Ceilings Description ▪ Hammerset anchor for push-through installation for ceiling suspensions. usable length t fix [mm] qty.4 0. shear load and oblique tension for type FDN 6/35 as well as for centre load for FDN 6/65 and stress due to fire) for anchoring light ceiling linings and panels according to DIN 18168. zinc-plated steel Type Art. Loads (for stress direction of centre load.25 200 100 100 Permissible loads Advantages/benefits ▪ Quick and simple hammerset installation reduces installation time. do not strike the expansion wedge. the correct drilling procedure and much more on page 303. You will find everything that has standards on page 313 under the keyword approvals. anchorage depth t [mm] hef [mm] anchor length l [mm] max. ▪ No special tools necessary. Technical DATA Ceiling nail FDN. ▪ A4 stainless steel version for outdoor use and in damp conditions. the ceiling nail is expanded against the hole wall.130 Ceiling nail FDN For cost-saving hammersetting.5 35 100 100 FIXING PRINCIPLES STANDARDS In detail: The general principles for installation. INSTALLATION Type of installation Installation tips ▪ Push-through installation ▪ When driving the ceiling nail into the hole. s≧ c≧ hmin ≧ The complete approval decision should be considered in the design and production of the anchoring.5 0. ID approval ▯ DIBt drill-Ø do [mm] min. zincplated steel Nail anchor FNA II with eye. ▪ Simple and easy setting with a few hammer blows reduces work.131 Nail anchor FNA II For cost-efficient hammerset installation. particularly with overhead installation. ▪ A4 stainless steel version for outdoor use and in damp conditions.ADVANTAGES AT A GLANCE Reduced drilling effort as the drill diameter (6 mm) equals the fixing diameter. High performance steel anchors . Advantages/benefits Ideal anchorage depth for anchoring in ceilings. e. pulls the cone into the expansion clip and expands against the hole wall. 1. Effortlessley sliding expansion clip for safe controlled expansion and low movement under load.g. Highly corrosion-resistant steel C (material no. fire protection boards. OVERVIEW Nail anchor FNA II with nail head. ▪ Only 6 mm hole diameter. zinc-plated steel Approved for: ▪ Lightweight ceilings and suspended ceilings according to DIN 18168 ▪ Statically comparable fixings in concrete C20/25 to C50/60 For fixing of: ▪ Squared timbers ▪ Battens ▪ Metal profiles ▪ Wire and nonius hangers ▪ Chains ▪ Cables ▪ Punched tapes ▪ Fire partitions ▪ Ventilation pipes ▪ Substructures made of wood and metal ▪ Ceilings ▪ Metal clamps Also suitable for: ▪ Concrete ≧C12/15 ▪ Natural stone with dense structure Description ▪ Nail anchor for hammerset installation ▪ The installed nail anchor expands automatically under load.4529) for applications in aggressive atmospheres. ▪ Fixing with different head designs for different areas of application. ▪ Little hammering force required. allowing sensitive materials to be fixed. FNA II . zincplated steel Nail anchor FNA II with thread. Usable lengths of 5 – 120 mm for many applications. zincplated steel Nail anchor FNA II with hook. . ID approval DIBt ETA drill-Ø do [mm] Nail anchor FNA II with eye. stainless steel resp. FIRE PROTECTION CORROSION Red hot: see page 308 for information about fire protection. qty. usable length t fix [mm] head diameter Ø [mm] pcs. FNA II-OE). per box FNA II 6 x 25 H FNA II 6 x 30 OE 44126 44127 8 5 ▯ n n 6 6 31 35 25 25 54 53 10 10 50 50 Nail anchor FNA II with thread. per box min. drill-hole depth for through fixings td [mm] FNA II 6 x 25/5 FNA II 6 x 30/5 FNA II 6 x 30/30 FNA II 6 x 30/50 FNA II 6 x 30/75 FNA II 6 x 30/100 FNA II 6 x 30/120 FNA II 6 x 30/5 A4 FNA II 6 x 30/30 A4 FNA II 6 x 30/5 C FNA II 6 x 30/30 C 1) 1) 44121 44115 44116 44117 44118 44119 44120 44122 44123 44124 44125 2 8 1 5 8 2 9 9 0 4 1 ▯ ▯ ▯ ▯ ▯ ▯ ▯ ▯ ▯ ▯ ▯ n n n n n n n n n n n 6 6 6 6 6 6 6 6 6 6 6 40 45 70 90 115 140 160 45 70 45 70 25 30 30 30 30 30 30 30 30 30 30 35 43 68 88 113 138 158 40 65 40 65 5 5 30 50 75 100 120 5 30 5 30 13 13 13 13 13 13 13 13 13 13 13 100 100 50 50 50 50 50 100 50 100 50 1) Prices and delivery times available on request.-No. high corrosion-resistant steel 1. ▪ Setting tool FNA S is recommended for installing channels.4529 anchor length max.-No.5 100 50 100 50 100 100 1) Max. anchorage depth hef [mm] anchor length l [mm] max. Nail anchor FNA II with hook. per box min. Installation tips Technical DATA Nail anchor FNA II with nail head. drill hole depth effect. 2) Without nut and washer. stainless steel resp. pre-positioned installation (only FNA II-H. 3) Prices and delivery times available on request. ID approval ▯ DIBt ETA drill-Ø do [mm] Nail anchor FNA II A4 resp.-No.. zinc-plated steel Type Art. anchorage depth for through depth fixings td [mm] hef [mm] DIBt ETA do [mm] l [mm] t fix [mm] M SW [mm] pcs. zinc-plated steel Type Art. for the fixing of pipe clamps.5 12 x 1. qty. ID approval drill-Ø Nail anchor FNA II A4 resp.4529 effect. All about corrosion and how you can avoid it is written on page 309. usable length thread width across nut washer (outer diameter x thickness) qty. installation torque = 4 Nm.132 High performance steel anchors INSTALLATION Type of installation ▪ Push-through resp. anchorage depth t [mm] hef [mm] anchor length l [mm] head diamete Ø [mm] pcs. zinc-plated steel min. drill-hole effect. zinc-plated steel Type Art. e. FNA II 6 x 25 M6/5 FNA II 6 x 30 M6/5 FNA II 6 x 30 M6 x 43 FNA II 6 x 30 M8/5 FNA II 6 x 30 M6/5 C 1) 3) 44111 1) 3) 44109 2) 44110 44114 1) 3) 44113 FNA II 6 x 30 M6/5 A4 1) 3) 44112 ▯ ▯ ▯ ▯ ▯ ▯ n n n n n n 6 6 6 6 6 6 40 45 40 45 45 45 25 30 30 30 30 30 45 50 43 50 50 50 5 5 5 5 5 M6 M6 M6 M8 M6 M6 10 10 13 10 10 14 x 6 14 x 6 18 x 8 12 x 1. g. ▪ Compressed air setting tool available upon request. high corrosion-resistant steel 1. FNA II C nail head. FNA II C with thread. 0 80 74) 45) 0.1 90° VRd [kN] 4.01) 1.6 NRd [kN] 0° Concrete C12/15 4.51) 4.m [kN] Concrete C20/25 7.8 7.m Vu. FNA S-SDS FNA S-SBO 61547 61548 8 5 for mounting on the drill bit (drill-Ø 6mm) 1 1 LOADS Mean ultimate loads.61) 1.21) 0. 1) 2) 3) 4) 5) High performance steel anchors .5 [kN] 7.9 - FNA II 6 x 30 gvz A4 C 30 40 6 4.min1) of one fixing point2) for c ≥ 50 mm and a ≥ 100 mm 3) 0.71) 0.6 Nrec [kN] 0° Concrete C12/15 4.0* [kN] 6.91) 1) 1.0 4.0* 6.21) 1.6 4.0 80 74) 45) 0.0* 7.1 90° VRd [kN] Design resistant loads FRd.1 90° Vrec [kN] 4.81) 0.min1) of one fixing point2) for c ≥ 50 mm and a ≥ 100 mm 3) 1.71) 2.m [mm] [mm] [mm] FNA II 6 x 25 gvz 25 35 6 4. a is the distance between the outer anchors of neighboured fixing points.61) 0.21) Concrete C20/25 to C50/60 [kN] 1.21) 1) 1.61) 4.8 Nrec 0° [kN] Concrete C20/25 to C50/60 4.71) 0.41) 1.71) Concrete C20/25 to C50/60 [kN] 1.71) 0.m [kN] 6. Recommended loads: material safety factors and safety factor for load Y L = 1.51) 0.71) 1.1 90° Vrec [kN] Recommended loads Frec. a group of two anchors with S 1 ≥ 50 mm or a group of four anchors with S 1 = S 2 ≥ 50 mm c is the distance of the outermost anchor of a fixing point to the concrete.0* FNA II 6 x 25 OE gvz 25 35 6 4. A fixing point can consist of a single anchor.61) 0.81) 1.2 4.51) 4.0 4.0* 5.1 Recommended bending moment Mrec 4.0 3.6 4.6 5.7 Nu. Non-cracked concrete FNA II 6 x 30 gvz A4 C 30 40 6 Anchor type Effective anchorage depth Drill hole depth Nominal drill hole diameter Mean ultimate loads Nu.51) 4.21) 1.71) 0.0 3.4 6.4 included.21) 0.0* 5.133 Nail anchor FNA II Technical DATA Machine setting tool FNA S-SDS Type Art. per box pcs.0* FNA II 6 x 30 gvz 25 35 6 4.0 5.5 Recommended loads Frec1) of one fixing point2) for c ≥ 100 mm and a ≥ 200 mm 3) 3.3 6.81) 1.8 4.31) Concrete C12/15 [kN] 1.9 4.71) 0.0 4.01) 1.51) 0.2 8.41) 1.9 4.91) Concrete C12/15 [kN] 0.0 5.m Concrete C12/15 hef h1 ≥ do Nu.71) 0.0* Design resistant loads FRd1) of one fixing point2) for c ≥ 100 mm and a ≥ 200 mm 3) 3.-No.71) 0.m and Vu.71) 0.0* Vu.0 0.0 5.0 6.0 5.0* 5. shear load and oblique tensile load at any angle. Design resistant loads: material safety factors included.51) 0.51) 0. ID Machine setting tool FNA S-SBO qty. For FNA II 6 M8: df ≤ 9mm.6 80 74) 45) hmin df ≤ T inst [mm] [mm] [Nm] 80 74) 45) Steel failure decisive The loads are valid for anxial tensile load. Only for FNA II 6 M6 and FNA II 6 M8.0* 5.0 80 4.8 NRd 0° [kN] Concrete C20/25 to C50/60 4.6 [Nm] Anchor characteristics Minimum structural component Clearance-hole in fixture to be attached Maximum torque *) 1. design resistant and recommended loads of one fixing point2) in normal-weight concrete C12/15 to C50/60. For stand off fixing. ▪ Plastic cap protects against contamination with drilling dust and ensures the thread remains free-running. . ▪ A4 stainless steel version for outdoor use and in damp conditions. this can be achieved with a lock nut. Advantages/benefits INSTALLATION Type of installation ▪ Pre-positioned installation ▪ Stand-off installation ▪ For correct installation. ▪ Suitable for all bolts or studs with metric thread. ▪ Observe the required screw-in depth in the fixing when determining the screw length Is: Length of anchor + Thickness of the building component tfix + Thickness of washer = Screw length (with threaded bolts please add thickness of nut) Installation tips FIXING PRINCIPLES In detail: The general principles for installation. the face of the fixing should be tightened against the back of the plate to be fixed. the correct drilling procedure and much more on page 303.134 Heavy-duty anchor SL M The classic steel anchor for all metric screws. High performance steel anchors OVERVIEW Heavy-duty anchor SL M. stainless steel Description ▪ Sleeve anchor with internal thread for pre-positioned installation ▪ When the screw or hexagon nut is tightened. zinc-plated steel Approved for: ▪ Non-cracked concrete C15/20 For fixing of: ▪ Steel constructions ▪ Handrails ▪ Consoles ▪ Ladders ▪ Cable trays ▪ Machines ▪ Staircases ▪ Gates ▪ Window elements ▪ Stand-off installations Heavy-duty anchor SLM-N A4. ▪ Surface-flush fixing allows the attached item to be removed and refitted several times. the cone is pulled into the expansion sleeve and expands it against the hole wall. 3 – 170* – 23.4 are included. values apply to screws with a strength classification 8.7 – 80 160 150 150 – 56.4 8.-No. ID drill-Ø do [mm] min.-No.8 – 9. Material safety factor γM depends on type of anchor. For further detailed information about Approvals please contact the fischer technical service department. qty.2 – 90 180 200 200 – M8 45 60 12 M 10 50 70 16 Non-cracked concrete M 16 62 110 24 M 20 77 130 30 M 24 90 150 35 hef [mm] h1 ≧ [mm] d0 [mm] Design resistant loads NRd and VRd [kN] Tensile Shear 0° NRd [kN] 90° VRd [kN] Recommended loads Nrec and Vrec [kN] Tensile Shear 0° Nrec [kN] 90° Vrec [kN] Recommended bending moment Mrec [Nm]. axial spacing1) smin [mm] 50 50 60 Min.0 – Component dimensions. For min.7 – 32.135 Heavy-duty anchor SL M Technical DATA Heavy-duty anchor SL M. drill hole depth effect.0 15.2 Mrec [Nm] A4 12. anchorage depth t [mm] hef [mm] anchor length l [mm] internal thread ds pcs. The conditions of application differ from those given in the German Approval. qty.9 – 45.9 – 57. anchorage depth t [mm] hef [mm] anchor length l [mm] internal thread ds pcs.4 – 296.2 8. stainless steel Type Art. Design resistant loads: Material safety factor γM is included.4* 7.7 11.0 – 513. CORROSION Rust prevention tips: Everything you need to know about corrosion and how to prevent it is on page 309. values apply to screws with a strength classification 8.6* – 18. per box SL M 16 SL M 20 SL M 24 50556 50557 50558 4 1 8 24 30 35 110 130 150 62 77 90 90 110 125 M 16 M 20 M 24 10 5 5 Heavy-duty anchor SLM-N A4.4 – 13.9 6. ID drill-Ø do [mm] min. per box SL M 8 N A4 SL M 10 N A4 50526 50527 7 4 12 16 60 70 45 50 52 60 M8 M 10 25 20 LOADS Mean ultimate loads and recommended loads for single anchors of fischer Heavy duty anchor SL M resp.5 32. Recommended loads: Material safety factor γM and safety factor for load γL = 1. edge distance the above described loads have to be reduced! (See design software “CC-Compufix”) All load values apply for concrete C20/25 without edge or spacing influence.8 – 23. axial spacing and min.2 – 75. zinc-plated steel Type Art. minimum axial spacings and edge distances Min. High performance steel anchors .5 25.2 5.8 and A4-70 resp.4* – 13.1 – 41.9 21.5 – 32.4 – 17.4 – 44. SL M-N A4 with large axial spacing and edge distance Anchor size Effective anchorage depth Drill hole depth Drill hole diameter Mean ultimate loads Nu and Vu [kN] Tensile Shear 0° 90° Nu [kN] Vu [kN] gvz A4 gvz A4 gvz A4 gvz A4 gvz A4 gvz A4 16. structural component thickness hmin [mm] 100 100 130 gvz 100 Required torque T inst [Nm] A4 25 45 – 1) * steel failure.8 and A4-70 respectively.4* 8. gvz 152.3 5. drill hole depth effect.0 24.6 – 117. edge distance1) cmin [mm] 90 100 120 Min. Advantages/benefits ▪ Quick and simple hammerset installation reduces installation time. per box do [mm] SW M pcs. zinc-plated steel Suitable for: ▪ Concrete ≧ C12/15 For fixing of: ▪ Gratings ▪ Machines ▪ Metal profiles ▪ Gates ▪ Consoles ▪ Steel constructions Description ▪ Hammerset anchor for push-through installation.-No. OVERVIEW Wall screw MR. zinc-plated steel Type Art. INSTALLATION Type of installation ▪ Push-through installation Technical DATA Hammerset wall bolt MR.136 Hammerset wall bolt MR High performance steel anchors Bolt anchor with distance-controlled impact expansion. ▪ Then the expansion pin is driven in to expand the anchor against the hole wall. ▪ The anchor is driven into the hole without the expansion pin. ID drill-Ø min. drill-hole effect. anchorage anchor length depth for through depth fixings td [mm] hef [mm] l [mm] max. usable length t fix [mm] width across nut thread qty. MR 8 MR 10 MR 12 50583 50584 50585 0 7 4 8 10 12 70 85 100 40 50 60 70 85 100 22 24 27 13 17 19 M8 M 10 M 12 25 20 10 . ID drill-Ø usable length min. 1 Nut Expansion element Spindle bolt Spindle bolt Spindle bolt 27 - 1 25 5 5 5 . ▪ Simple hammerset installation without additional setting tool. ▪ Protected internal thread and high-quality steel increase the long life of the spindle bolt and improve cost efficiency. Technical DATA Fixing set FDBB Expansion element FDBB SE Spindle bolt Type Art. ▪ Robust unit specially for rough on-site conditions. FDBB 16/50 Set FDBB 16 SE FDBB 16/50/160 SB FDBB 16/100/210 SB FDBB 16/150/260 SB 90680 90681 91947 92962 92964 4 1 7 9 3 16 16 16 16 16 50 50 100 150 135 135 185 235 200 200 250 300 60 60 60 60 1 Expansion element 16 SE.137 Fixing set for Diamond Drills FDBB OVERVIEW Fixing set FDBB. drill-hole total length depth for approx. and the spindle bolt is fitted with a new expansion element and re-used. through fixings da [mm] td [mm] [mm] anchorage depth contents FDBB SB width across qty. ▪ Active controlled expansion behaviour guarantees high security in use.-No. ▪ Large steel cross-section at the concrete surface provides high steel load-bearing capability. ▪ The nut can either be tightened with a hammer or a wrench. 1 Washer. the tapered bolt is pulled into the expansion clip and expands it against the hole wall. ▪ The expansion element stays in the hole on disassembly. per box nut do [mm] hef [mm] SW pcs. 1 Spindle bolt 16/50/160. Advantages/benefits INSTALLATION Type of installation ▪ Push-through installation ▪ Pre-positioned installation Installation tips ▪ Spindle bolt and expansion element need to be fitted before installation. zinc-plated steel Suitable for: ▪ Concrete ≧ C12/15 ▪ Natural stone with dense structure For fixing of: ▪ Diamond drills ▪ Diamond saws High performance steel anchors Description ▪ Fixing set for diamond drills and diamond saws ▪ When the nut is tightened. also tolerates skew bolt positions and jerky tilting of the drill bit. 138 Notes High performance steel anchors nOTES pAGE Please use this page to record your notes and remarks .